-- MIB file created 05-Aug-2016 16:43:22, by -- SMICng version 2.2.11-beta(PRO)(Solaris), January 20, 2001. Enterprise key cisco.com CISCO-MPLS-TE-STD-EXT-MIB DEFINITIONS ::= BEGIN -- From file: "CISCO-MPLS-TE-STD-EXT-MIB.my" -- Compile options "4 7 F H N W 03 06 0B 0G 0N 0T" IMPORTS mplsTunnelIndex, mplsTunnelInstance, mplsTunnelIngressLSRId, mplsTunnelEgressLSRId, mplsTunnelAdminStatus, mplsTunnelOperStatus, mplsTunnelName, mplsTunnelARHopListIndex FROM MPLS-TE-STD-MIB InetAddressType, InetAddress FROM INET-ADDRESS-MIB ciscoMgmt FROM CISCO-SMI Counter, Gauge FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212 TRAP-TYPE FROM RFC-1215; cmplsTeStdExtMIB OBJECT IDENTIFIER ::= { ciscoMgmt 738 } -- MODULE-IDENTITY -- LastUpdated -- 201608050000Z -- OrgName -- Cisco Systems, Inc. -- ContactInfo -- Cisco Systems -- Customer Service -- Postal: 170 W Tasman Drive -- San Jose, CA 95134 -- USA -- Tel: +1 800 553-NETS -- E-mail: cs-snmp@cisco.com -- Descr -- This MIB module contains Cisco specific managed object -- definitions for MPLS Traffic Engineering (TE), not contained in -- MPLS-TE-STD-MIB. -- The auto bandwidth feature enables MPLS TE Tunnels to adapt -- automatically their bandwidth to their actual load. -- RevDate -- 201608050000Z -- RevDescr -- Added a new table cmplsTunnelLoadshareTable. -- -- Added a new scalar object cmplsTeLoadshareBalance. -- -- Added new values to cmplsTunnelReoptReason. -- -- Added a new object cmplsTeFailReasonRev which deprecates -- cmplsTeFailReason. -- -- Updated cmplsTeFailReason description and MIN-ACCESS -- in complaince. -- -- Added new value frrSoftPreemption to cmplsTunnelPreemptionType. -- -- Deprecated the complaince cmplsTeStdExtMIBComplianceRev3 and -- group cmplsTeStdExtMIBFailTeTrapObjectsGroup. -- -- Added new complaince cmplsTeStdExtMIBComplianceRev4 and -- groups cmplsTeStdExtMIBFailTeTrapObjectsGroupRev1 and -- cmplsTeStdExtMIBLoadShareObjectsGroup. -- RevDate -- 201202220000Z -- RevDescr -- Add preferredTreeExists to cmplsTunnelReooptReason -- RevDate -- 201110040000Z -- RevDescr -- Added cmplsTeBringupFail trap -- RevDate -- 201101070000Z -- RevDescr -- Added softPreemption to the enum cmplsTunnelReoptReason. -- RevDate -- 201010200000Z -- RevDescr -- added cmplsTunnelReRoutePendingClearReason to be sent along the -- notification cmplsTunnelReRoutePendingClear -- RevDate -- 201009230000Z -- RevDescr -- New traps and related objects definitions. -- RevDate -- 201005270000Z -- RevDescr -- Initial version of this MIB module. cmplsTeStdExtMIBNotifs OBJECT IDENTIFIER ::= { cmplsTeStdExtMIB 0 } cmplsTeStdExtMIBObjects OBJECT IDENTIFIER ::= { cmplsTeStdExtMIB 1 } cmplsTeStdExtMIBConform OBJECT IDENTIFIER ::= { cmplsTeStdExtMIB 2 } cmplsTeStdExtMIBObjectsGlobal OBJECT IDENTIFIER ::= { cmplsTeStdExtMIBObjects 5 } cmplsTeStdExtMIBCompliances OBJECT IDENTIFIER ::= { cmplsTeStdExtMIBConform 1 } cmplsTeStdExtMIBGroups OBJECT IDENTIFIER ::= { cmplsTeStdExtMIBConform 2 } CmplsTeTunnelDiag ::= INTEGER { unknonw(1), bfdSessionBringupTimeout(2) } -- TEXTUAL-CONVENTION -- Status -- mandatory -- Descr -- A common TE diagnostic code -- -- - unknown: failure reason unknown -- - bfdSessionBringupTimeout: BFD session failed to come up before -- timeout CmplsTunnelBWPercent ::= Gauge(0..100) -- TEXTUAL-CONVENTION -- DspHint -- d -- Status -- mandatory -- Descr -- A fraction of the bandwidth expressed in percentage. cmplsTunnelAutoBWTable OBJECT-TYPE SYNTAX SEQUENCE OF CmplsTunnelAutoBWEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table is used in order to manage auto bandwidth data. This table is sparse dependent on the mplsTunnelTable. An entry in this table exists for each mplsTunnelEntry with a mplsTunnelRole of 'head' or 'headTail'. Each row contains auto-bandwidth data for the tunnel identified by the indexes defined later. An entry is created as soon as a 'head' or 'headTail' MPLS TE tunnel is configured in the system." ::= { cmplsTeStdExtMIBObjects 1 } cmplsTunnelAutoBWEntry OBJECT-TYPE SYNTAX CmplsTunnelAutoBWEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A conceptual row in cmplsTunnelAutoBWTable. There is an entry in this table for each MPLS-TE tunnel with mplsTunnelRole equals to 'head' or 'headTail'." INDEX { mplsTunnelIndex, mplsTunnelInstance, mplsTunnelIngressLSRId, mplsTunnelEgressLSRId } ::= { cmplsTunnelAutoBWTable 1 } CmplsTunnelAutoBWEntry ::= SEQUENCE { cmplsTunnelAutoBWStatus INTEGER, cmplsTunnelAutoBWMin Gauge, cmplsTunnelAutoBWMax Gauge, cmplsTunnelAutoBWAdjThreshPercs CmplsTunnelBWPercent, cmplsTunnelAutoBWAdjThreshBW Gauge, cmplsTunnelAutoBWOverflowThreshPercs CmplsTunnelBWPercent, cmplsTunnelAutoBWOverflowThreshBW Gauge, cmplsTunnelAutoBWOverflowLimit Gauge, cmplsTunnelAutoBWUnderflowThreshPercs CmplsTunnelBWPercent, cmplsTunnelAutoBWUnderflowThreshBW Gauge, cmplsTunnelAutoBWUnderflowLimit Gauge, cmplsTunnelAutoBWApplicationFrequency Gauge, cmplsTunnelAutoBWCollectionFrequency Gauge, cmplsTunnelAutoBWLastAppliedBW Gauge, cmplsTunnelAutoBWApplications Counter, cmplsTunnelAutoBWLastApplicationTrigger INTEGER, cmplsTunnelAutoBWOverflowApplications Counter, cmplsTunnelAutoBWOverflowOccurrences Counter, cmplsTunnelAutoBWUnderflowApplications Counter, cmplsTunnelAutoBWUnderflowOccurrences Counter, cmplsTunnelAutoBWUnderflowHighestBW Gauge, cmplsTunnelAutoBWRequested Gauge, cmplsTunnelAutoBWSignaled Gauge, cmplsTunnelAutoBWCollectOnlyRequested Gauge, cmplsTunnelAutoBWHighest Gauge, cmplsTunnelAutoBWCollectedSamples Counter, cmplsTunnelAutoBWJitter Gauge, cmplsTunnelAutoBWAppRejectReason INTEGER } cmplsTunnelAutoBWStatus OBJECT-TYPE SYNTAX INTEGER { autoBWDisabled(1), autoBWEnabled(2), autoBWCollectOnlyMode(3) } ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the operational status [or mode] of the auto bandwidth algorithm: - autoBWDisabled: The auto-bandwidth algorithm is not running; - autoBWEnabled: The auto-bandwidth algorithm is running; - autoBWCollectOnlyMode: The auto-bandwidth algorithm is running, but the bandwidth applications are disabled;" DEFVAL { autoBWDisabled } ::= { cmplsTunnelAutoBWEntry 1 } cmplsTunnelAutoBWMin OBJECT-TYPE SYNTAX Gauge -- Units -- kbps ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies the minimum bandwidth that the auto-bandwidth algorithm can apply to a tunnel when the adjustment threshold is overcome. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'." DEFVAL { 0 } ::= { cmplsTunnelAutoBWEntry 2 } cmplsTunnelAutoBWMax OBJECT-TYPE SYNTAX Gauge -- Units -- kbps ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies the maximum bandwidth that the auto-bandwidth algorithm can apply to a tunnel when the adjustment threshold is overcome. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'." DEFVAL { 100 } ::= { cmplsTunnelAutoBWEntry 3 } cmplsTunnelAutoBWAdjThreshPercs OBJECT-TYPE SYNTAX CmplsTunnelBWPercent -- Rsyntax Gauge(0..100) ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies the adjustment threshold percentage that needs to be overcome in order to trigger a new bandwidth application. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'." DEFVAL { 10 } ::= { cmplsTunnelAutoBWEntry 4 } cmplsTunnelAutoBWAdjThreshBW OBJECT-TYPE SYNTAX Gauge -- Units -- kbps ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies the adjustment threshold bandwidth that needs to be overcome in order to trigger a new bandwidth application. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'." DEFVAL { 10 } ::= { cmplsTunnelAutoBWEntry 5 } cmplsTunnelAutoBWOverflowThreshPercs OBJECT-TYPE SYNTAX CmplsTunnelBWPercent -- Rsyntax Gauge(0..100) ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies the adjustment threshold percentage that needs to be overcome in order to trigger an overflow occurrence. If the application period has not completed when a cmplsTunnelAutoBWOverflowLimit overflow has occurred, a new bandwidth will be applied. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'." DEFVAL { 10 } ::= { cmplsTunnelAutoBWEntry 6 } cmplsTunnelAutoBWOverflowThreshBW OBJECT-TYPE SYNTAX Gauge -- Units -- kbps ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies the adjustment threshold bandwidth that needs to be overcome in order to trigger an overflow occurrence. If the application period has not completed when a cmplsTunnelAutoBWOverflowLimit overflow has occurred, a new bandwidth will be applied. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'." DEFVAL { 10 } ::= { cmplsTunnelAutoBWEntry 7 } cmplsTunnelAutoBWOverflowLimit OBJECT-TYPE SYNTAX Gauge ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies the number of consecutive collections exceeding overflow threshold. If the application period has not completed when a cmplsTunnelAutoBWOverflowLimit overflow has occurred, a new bandwidth will be applied. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'." DEFVAL { 1 } ::= { cmplsTunnelAutoBWEntry 8 } cmplsTunnelAutoBWUnderflowThreshPercs OBJECT-TYPE SYNTAX CmplsTunnelBWPercent -- Rsyntax Gauge(0..100) ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies the adjustment threshold percentage that needs to be overcome in order to trigger an underflow occurrence. If the application period has not completed when a cmplsTunnelAutoBWUnderflowLimit underflow has occurred, a new bandwidth will be applied. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'." DEFVAL { 10 } ::= { cmplsTunnelAutoBWEntry 9 } cmplsTunnelAutoBWUnderflowThreshBW OBJECT-TYPE SYNTAX Gauge -- Units -- kbps ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies the adjustment threshold bandwidth that needs to be overcome in order to trigger an underflow occurrence. If the application period has not completed when a cmplsTunnelAutoBWUnderflowLimit underflow has occurred, a new bandwidth will be applied. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'." DEFVAL { 1 } ::= { cmplsTunnelAutoBWEntry 10 } cmplsTunnelAutoBWUnderflowLimit OBJECT-TYPE SYNTAX Gauge ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies the number of consecutive collections under the underflow threshold. If the application period has not completed when a cmplsTunnelAutoBWUnderflowLimit underflow has occurred, a new bandwidth will be applied. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'." DEFVAL { 1 } ::= { cmplsTunnelAutoBWEntry 11 } cmplsTunnelAutoBWApplicationFrequency OBJECT-TYPE SYNTAX Gauge -- Units -- seconds ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies the bandwidth application period. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'." DEFVAL { 300 } ::= { cmplsTunnelAutoBWEntry 12 } cmplsTunnelAutoBWCollectionFrequency OBJECT-TYPE SYNTAX Gauge -- Units -- seconds ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies the sampling period for data rates. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'." DEFVAL { 300 } ::= { cmplsTunnelAutoBWEntry 13 } cmplsTunnelAutoBWLastAppliedBW OBJECT-TYPE SYNTAX Gauge -- Units -- kbps ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the last bandwidth applied by the auto-bandwidth algorithm. It will be set to zero if no bandwidth has been applied yet. If mplsTunnelInstance is zero this object will be set to zero. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'." ::= { cmplsTunnelAutoBWEntry 14 } cmplsTunnelAutoBWApplications OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the number of auto bandwidths applied. If mplsTunnelInstance is zero this object will be set to zero. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'." ::= { cmplsTunnelAutoBWEntry 15 } cmplsTunnelAutoBWLastApplicationTrigger OBJECT-TYPE SYNTAX INTEGER { applicationNone(1), applicationPeriodic(2), applicationManual(3), applicationOverflow(4), applicationUnderflow(5) } ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the trigger reason for the last bandwidth application. If mplsTunnelInstance is zero this object will be set to 'applicationNone'. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'." ::= { cmplsTunnelAutoBWEntry 16 } cmplsTunnelAutoBWOverflowApplications OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the number of bandwidth applications due to overflow occurrences. If mplsTunnelInstance is zero this object will be set to zero. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'." ::= { cmplsTunnelAutoBWEntry 17 } cmplsTunnelAutoBWOverflowOccurrences OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the number of overflow occurrences since last application period. If mplsTunnelInstance is zero this object will be set to zero. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'." ::= { cmplsTunnelAutoBWEntry 18 } cmplsTunnelAutoBWUnderflowApplications OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the number of bandwidth applications due to underflow occurrences. If mplsTunnelInstance is zero this object will be set to zero. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'." ::= { cmplsTunnelAutoBWEntry 19 } cmplsTunnelAutoBWUnderflowOccurrences OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the number of underflow occurrences since last application period. If mplsTunnelInstance is zero this object will be set to zero. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'." ::= { cmplsTunnelAutoBWEntry 20 } cmplsTunnelAutoBWUnderflowHighestBW OBJECT-TYPE SYNTAX Gauge -- Units -- kbps ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the highest sample collected during an underflow sequence. If mplsTunnelInstance is zero this object will be set to zero. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'." ::= { cmplsTunnelAutoBWEntry 21 } cmplsTunnelAutoBWRequested OBJECT-TYPE SYNTAX Gauge -- Units -- kpbs ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the bandwidth requested by the auto-bandwidth algorithm. If mplsTunnelInstance is zero this object will be set to zero. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'." ::= { cmplsTunnelAutoBWEntry 22 } cmplsTunnelAutoBWSignaled OBJECT-TYPE SYNTAX Gauge -- Units -- kpbs ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the bandwidth signaled by the auto-bandwidth algorithm. If mplsTunnelInstance is zero this object will be set to zero. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'." ::= { cmplsTunnelAutoBWEntry 23 } cmplsTunnelAutoBWCollectOnlyRequested OBJECT-TYPE SYNTAX Gauge -- Units -- kpbs ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the bandwidth that would have been requested by the auto-bandwidth algorithm if the auto-bandwidth functionality was enabled. If the collect only mode is enabled, the bandwidth change request will not be executed. If mplsTunnelInstance is zero this object will be set to zero. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'." ::= { cmplsTunnelAutoBWEntry 24 } cmplsTunnelAutoBWHighest OBJECT-TYPE SYNTAX Gauge -- Units -- kpbs ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the highest bandwidth sampled by the auto-bandwidth algorithm. If mplsTunnelInstance is zero this object will be set to zero. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'." ::= { cmplsTunnelAutoBWEntry 25 } cmplsTunnelAutoBWCollectedSamples OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the samples collected since the last auto-bandwidth application. If mplsTunnelInstance is zero this object will be set to zero. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'." ::= { cmplsTunnelAutoBWEntry 26 } cmplsTunnelAutoBWJitter OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the auto-bandwidth application jitter. Jitter is the extra time to be added to the application interval the first time the auto bandwidth is applied. If mplsTunnelInstance is zero this object will be set to zero. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'." DEFVAL { 0 } ::= { cmplsTunnelAutoBWEntry 27 } cmplsTunnelAutoBWAppRejectReason OBJECT-TYPE SYNTAX INTEGER { applicationAllowed(1), autoBWDisabled(2), tunnelIsDown(3), tunnelIsFRR(4), tunnelIsBackup(5), tunnelIsLockDown(6) } ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the reason for the bandwidth application rejection. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'." ::= { cmplsTunnelAutoBWEntry 28 } cmplsTeTunnelReasonTable OBJECT-TYPE SYNTAX SEQUENCE OF CmplsTeTunnelReasonEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table is used in order to indicate the causes for the notifications." ::= { cmplsTeStdExtMIBObjects 2 } cmplsTeTunnelReasonEntry OBJECT-TYPE SYNTAX CmplsTeTunnelReasonEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A conceptual row in cmplsTunnelReasonTable." INDEX { mplsTunnelIndex, mplsTunnelInstance, mplsTunnelIngressLSRId, mplsTunnelEgressLSRId } ::= { cmplsTeTunnelReasonTable 1 } CmplsTeTunnelReasonEntry ::= SEQUENCE { cmplsTunnelReoptReason INTEGER, cmplsTunnelInsuffBWFailedOperation INTEGER, cmplsTunnelPreemptionType INTEGER, cmplsTunnelPreemptionLinkAddrType InetAddressType, cmplsTunnelPreemptionLinkAddr InetAddress, cmplsTunnelReRoutePendingClearReason INTEGER } cmplsTunnelReoptReason OBJECT-TYPE SYNTAX INTEGER { unknown(1), periodicTimerExpiry(2), bandwidthCLIChange(3), bandwidthOverflow(4), bandwidthUnderflow(5), bandwidthAdjustment(6), fastReRoute(7), cliRequest(8), metricTypeChange(9), preferredPathExists(10), poSwitchoverTrigger(11), bandwidthChange(12), autoBandwidth(13), remergeError(14), dueToMaximumMetric(15), pathProtectionSwitchover(16), iEPEnableReoptimization(17), affinityPathVerificationFail(18), softPreemption(19), preferredTreeExists(20), costLimitPathVerificationFail(21), linkupReopt(22), iEPChange(23), poChange(24), destChange(25), bfdSessionTypeChange(26) } ACCESS not-accessible STATUS mandatory DESCRIPTION "This object indicates the reason of the tunnel reoptimization: - unknown: the reason is not known - periodicTimerExpiry: Periodic Reoptimization - bandwidthCLIChange: the tunnel bandwidth has been changed from CLI - bandwidthOverflow: an auto-bandwidth overflow occurred - bandwidthUnderflow: an auto-bandwidth underflow occured - bandwidthAdjustment: an auto-bandwidth application occured - fastReRoute: a fast re-route occured - cliRequest: User-triggerred - metricTypeChange: tunnel metric type has been changed from CLI - preferredPathExists: preferred-path-exists message received from a downstream node - poSwitchoverTrigger: User-requested path-option switchover - bandwidthChange: bandwidth change - autoBandwidth: Auto Bandwidth - remergeError: Remerge Error - dueToMaximumMetric: Reoptimization due to receiving an LSA with MAX metric - pathProtectionSwitchover: Path Protection Switchover - iEPEnableReoptimization: IEP Enable Reoptimization - affinityPathVerificationFail: Affinity path verification failure - softPreemption: soft preemption (see RFC 5712) - preferredTreeExists: preferred-tree-exists message received from a downstream node - costLimitPathVerificationFail: Cost Limit path verification failure - linkupReopt: link state up - iEPChangeReoptimization: inuse explicit-path change - poChangeReoptimization: inuse path-option change - bfdSessionTypeChange: a bfd session type change occured This object is intended to be included in the trap mplsTunnelReoptimized defined in MPLS-TE-STD-MIB." -- DEFVAL { unknown } ::= { cmplsTeTunnelReasonEntry 1 } cmplsTunnelInsuffBWFailedOperation OBJECT-TYPE SYNTAX INTEGER { unknown(1), failedToSetup(2), failedToReoptimize(3) } ACCESS not-accessible STATUS mandatory DESCRIPTION "This object indicates whether the tunnel could not be setup or reoptimized because of insufficient bandwidth: - unknown: the reason is not known - failedToSetup: insufficient bandwidth during initial setup - failedToReoptimize: insufficient bandwidth during reoptimization" -- DEFVAL { unknown } ::= { cmplsTeTunnelReasonEntry 2 } cmplsTunnelPreemptionType OBJECT-TYPE SYNTAX INTEGER { unknown(1), hardPreemption(2), softPreemption(3), frrSoftPreemption(4) } ACCESS not-accessible STATUS mandatory DESCRIPTION "This object indicates LSP Preemption type of this LSP: - unknown: the type is not known - hardPreemption: the preempted LSP resources are freed immediately; the LSP is broken immediately and the traffic is disrupted. - softPreemption: the resources release pending on the reoptimization of this LSP. The head of the LSP reroutes the traffic before the LSP is broken. - frrSoftPreemption: similar to softPreemption. In this case the traffic of the soft preempted LSP is switched to the backup. See: Farrel, A., Interim Report on MPLS Pre-emption, draft-farrel-mpls-preemption-interim-00.txt, work in progress" ::= { cmplsTeTunnelReasonEntry 3 } cmplsTunnelPreemptionLinkAddrType OBJECT-TYPE SYNTAX InetAddressType -- Rsyntax INTEGER { -- ?? enum value of zero may cause problems -- unknown(0), -- ipv4(1), -- ipv6(2), -- ipv4z(3), -- ipv6z(4), -- dns(16) -- } ACCESS not-accessible STATUS mandatory DESCRIPTION "This object indicates the address type of the link where the preemption occurs - another, higher priority LSP is being admitted on this link and there is not enough bandwidth for it causing this LSP to be preempted (removed) from this link: - unknown: the object cmplsTunnelPreemptionLinkAddr does not contain any address - ipv4: the object cmplsTunnelPreemptionLinkAddr contains the IPv4 address - ipv6: the object cmplsTunnelPreemptionLinkAddr contains the IPv6 address" ::= { cmplsTeTunnelReasonEntry 4 } cmplsTunnelPreemptionLinkAddr OBJECT-TYPE SYNTAX InetAddress -- Rsyntax OCTET STRING(SIZE(0..255)) ACCESS not-accessible STATUS mandatory DESCRIPTION "This object indicates the address of the link where the preemption occurs - another, higher priority LSP is being admitted on this link and there is not enough bandwidth for it causing this LSP to be preempted (removed) from this link." ::= { cmplsTeTunnelReasonEntry 5 } cmplsTunnelReRoutePendingClearReason OBJECT-TYPE SYNTAX INTEGER { unknown(1), reoptimized(2), reinstated(3) } ACCESS not-accessible STATUS mandatory DESCRIPTION "This object indicates the reason why the tunnel is not longer in the reroute pending state: - unknown: the reason is unknown - reoptimized: the tunnel has been reoptimized - reinstated: the tunnel has been reinstated" ::= { cmplsTeTunnelReasonEntry 6 } cmplsTeTunnelFailReasonTable OBJECT-TYPE SYNTAX SEQUENCE OF CmplsTeTunnelFailReasonEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table is used in order to indicate the causes for the MPLS TE tunnel failure notifications." ::= { cmplsTeStdExtMIBObjects 3 } cmplsTeTunnelFailReasonEntry OBJECT-TYPE SYNTAX CmplsTeTunnelFailReasonEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A conceptual row in the cmplsTeTunnelFailReasonTable." INDEX { mplsTunnelIndex, mplsTunnelInstance, mplsTunnelIngressLSRId, mplsTunnelEgressLSRId, mplsTunnelARHopListIndex } ::= { cmplsTeTunnelFailReasonTable 1 } CmplsTeTunnelFailReasonEntry ::= SEQUENCE { cmplsTeFailReasonType INTEGER, cmplsTeFailReason INTEGER, cmplsTeFailReasonRev INTEGER } cmplsTeFailReasonType OBJECT-TYPE SYNTAX INTEGER { unknown(1), bfd(2), generalTe(3) } ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the type (category) of fail reason." ::= { cmplsTeTunnelFailReasonEntry 1 } cmplsTeFailReason OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS deprecated DESCRIPTION "This object indicates specific fail reason value based on the fail reason type indicated by cmplsTeFailReasonType. Fail Reason Type Fail Reason Value Type ---------------- ----------------------- bfd(2) CiscoBfdDiag generalTe(3) CmplsTeTunnelDiag This object is replaced by cmplsTeFailReasonRev" ::= { cmplsTeTunnelFailReasonEntry 2 } cmplsTeFailReasonRev OBJECT-TYPE SYNTAX INTEGER { --?? enum value of zero may cause problems -- noDiagnostic(0), controlDetectionTimeExpired(1), echoFunctionFailed(2), neighborSignaledSessionDown(3), forwardingPlaneReset(4), pathDown(5), concatenatedPathDown(6), administrativelyDown(7), reverseConcatenatedPathDown(8), unknown(9), bfdSessionBringupTimeout(21) } ACCESS not-accessible STATUS mandatory DESCRIPTION "This object provieds more deails on fail reason. cmplsTeFailReason values for reasonType bfd(2) mirror the CiscoBfdDiag values: - noDiagnostic No bfd diagnostic info - controlDetectionTimeExpired Control Detection Timer Expired - echoFunctionFailed Echo Function Failed - neighborSignaledSessionDown Neighbor Signaled Session Down - forwardingPlaneReset Forwarding Plane Reset - pathDown Path Down - concatenatedPathDown Concatenated Path Down - administrativelyDown Administratively Down - reverseConcatenatedPathDown Reverse Concatenated Path Down - unknown Unknown error code cmplsTeFailReason values for reasonType generalTe(3) mirror the CmplsTeTunnelDiag values: - unknown Unknown error code - bfdSessionBringupTimeout bfd session failed to come up before timeout" ::= { cmplsTeTunnelFailReasonEntry 3 } cmplsTunnelLoadshareTable OBJECT-TYPE SYNTAX SEQUENCE OF CmplsTunnelLoadshareEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table is used in order to manage load data." ::= { cmplsTeStdExtMIBObjects 4 } cmplsTunnelLoadshareEntry OBJECT-TYPE SYNTAX CmplsTunnelLoadshareEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A conceptual row in cmplsTunnelLoadshareTable. There is an entry in this table for each MPLS-TE tunnel." INDEX { mplsTunnelIndex, mplsTunnelInstance, mplsTunnelIngressLSRId, mplsTunnelEgressLSRId } ::= { cmplsTunnelLoadshareTable 1 } CmplsTunnelLoadshareEntry ::= SEQUENCE { cmplsTunnelLoadShare Gauge } cmplsTunnelLoadShare OBJECT-TYPE SYNTAX Gauge ACCESS read-write STATUS mandatory DESCRIPTION "This object indicates the Load-share as defined by the bandwidth attribute (default) or explicitly configured using the load-share command under tunnel configuration." DEFVAL { 0 } ::= { cmplsTunnelLoadshareEntry 1 } cmplsTeLoadshareBalance OBJECT-TYPE SYNTAX INTEGER { --?? enum value of zero may cause problems -- equal(0), unequal(1) } ACCESS read-write STATUS mandatory DESCRIPTION "This object indicates if the load-share balance is equal or unequal." -- DEFVAL { equal } ::= { cmplsTeStdExtMIBObjectsGlobal 1 } cmplsTunnelPreempt TRAP-TYPE -- Reverse mappable trap ENTERPRISE cmplsTeStdExtMIB VARIABLES { mplsTunnelAdminStatus, mplsTunnelOperStatus, mplsTunnelName, cmplsTunnelPreemptionType, cmplsTunnelPreemptionLinkAddrType, cmplsTunnelPreemptionLinkAddr } -- Status -- mandatory DESCRIPTION "This notification is generated when a MPLS TE tunnel is preempted." ::= 1 cmplsTunnelInsuffBW TRAP-TYPE -- Reverse mappable trap ENTERPRISE cmplsTeStdExtMIB VARIABLES { mplsTunnelAdminStatus, mplsTunnelOperStatus, mplsTunnelName, cmplsTunnelInsuffBWFailedOperation } -- Status -- mandatory DESCRIPTION "This notification is generated when a MPLS TE tunnel could not be setup or reoptimized." ::= 2 cmplsTunnelReRoutePending TRAP-TYPE -- Reverse mappable trap ENTERPRISE cmplsTeStdExtMIB VARIABLES { mplsTunnelAdminStatus, mplsTunnelOperStatus, mplsTunnelName } -- Status -- mandatory DESCRIPTION "This notification is generated when re-route is required for the tunnel." ::= 3 cmplsTunnelReRoutePendingClear TRAP-TYPE -- Reverse mappable trap ENTERPRISE cmplsTeStdExtMIB VARIABLES { mplsTunnelAdminStatus, mplsTunnelOperStatus, mplsTunnelName, cmplsTunnelReRoutePendingClearReason } -- Status -- mandatory DESCRIPTION "This notification is generated when tunnel no longer needs to be re-routed." ::= 4 cmplsTunnelBringupFail TRAP-TYPE -- Reverse mappable trap ENTERPRISE cmplsTeStdExtMIB VARIABLES { mplsTunnelName, cmplsTeFailReasonType } -- Status -- mandatory DESCRIPTION "This notification is generated when MPLS TE tunnel failed to come up" ::= 5 cmplsTeStdExtMIBAutoBWObjectGroup OBJECT IDENTIFIER ::= { cmplsTeStdExtMIBGroups 1 } -- OBJECT-GROUP -- Status -- mandatory -- Descr -- This contains the main MPLS TE extensions groups. -- objects -- cmplsTunnelAutoBWStatus, cmplsTunnelAutoBWMin, -- cmplsTunnelAutoBWMax, cmplsTunnelAutoBWAdjThreshPercs, -- cmplsTunnelAutoBWAdjThreshBW, -- cmplsTunnelAutoBWApplicationFrequency, -- cmplsTunnelAutoBWCollectionFrequency, -- cmplsTunnelAutoBWLastAppliedBW, cmplsTunnelAutoBWApplications, -- cmplsTunnelAutoBWLastApplicationTrigger, -- cmplsTunnelAutoBWOverflowApplications, -- cmplsTunnelAutoBWOverflowOccurrences, -- cmplsTunnelAutoBWUnderflowApplications, -- cmplsTunnelAutoBWUnderflowOccurrences, -- cmplsTunnelAutoBWUnderflowHighestBW, -- cmplsTunnelAutoBWRequested, cmplsTunnelAutoBWSignaled, -- cmplsTunnelAutoBWCollectOnlyRequested, -- cmplsTunnelAutoBWHighest, cmplsTunnelAutoBWCollectedSamples, -- cmplsTunnelAutoBWAppRejectReason cmplsTeStdExtMIBAutoBWOptionalGroup OBJECT IDENTIFIER ::= { cmplsTeStdExtMIBGroups 2 } -- OBJECT-GROUP -- Status -- mandatory -- Descr -- This contains the optional MPLS TE extensions groups. -- objects -- cmplsTunnelAutoBWOverflowThreshPercs, -- cmplsTunnelAutoBWOverflowThreshBW, -- cmplsTunnelAutoBWOverflowLimit, -- cmplsTunnelAutoBWUnderflowThreshPercs, -- cmplsTunnelAutoBWUnderflowThreshBW, -- cmplsTunnelAutoBWUnderflowLimit, cmplsTunnelAutoBWJitter cmplsTeStdExtMIBTrapObjectsGroup OBJECT IDENTIFIER ::= { cmplsTeStdExtMIBGroups 3 } -- OBJECT-GROUP -- Status -- deprecated -- Descr -- This contains the MPLS TE extended traps objects. -- This object is replaced by -- cmplsTeStdExtMIBTrapObjectsGroupRev1 -- objects -- cmplsTunnelReoptReason, cmplsTunnelInsuffBWFailedOperation, -- cmplsTunnelPreemptionType, cmplsTunnelPreemptionLinkAddrType, -- cmplsTunnelPreemptionLinkAddr cmplsTeStdExtMIBTrapObjectsGroupRev1 OBJECT IDENTIFIER ::= { cmplsTeStdExtMIBGroups 4 } -- OBJECT-GROUP -- Status -- mandatory -- Descr -- This contains the optional MPLS TE extensions groups. -- objects -- cmplsTunnelReoptReason, cmplsTunnelInsuffBWFailedOperation, -- cmplsTunnelPreemptionType, cmplsTunnelPreemptionLinkAddrType, -- cmplsTunnelPreemptionLinkAddr, -- cmplsTunnelReRoutePendingClearReason cmplsTeStdExtMIBFailTeTrapObjectsGroup OBJECT IDENTIFIER ::= { cmplsTeStdExtMIBGroups 7 } -- OBJECT-GROUP -- Status -- deprecated -- Descr -- This contains the MPLS TE extended traps objects related to BFD -- over TE LSP. -- -- This object is replaced by -- cmplsTeStdExtMIBFailTeTrapObjectsGroupRev1 -- objects -- cmplsTeFailReasonType, cmplsTeFailReason cmplsTeStdExtMIBLoadShareObjectsGroup OBJECT IDENTIFIER ::= { cmplsTeStdExtMIBGroups 8 } -- OBJECT-GROUP -- Status -- mandatory -- Descr -- This contains the MPLS TE extended objects related to -- TE loadshare. -- objects -- cmplsTunnelLoadShare, cmplsTeLoadshareBalance cmplsTeStdExtMIBFailTeTrapObjectsGroupRev1 OBJECT IDENTIFIER ::= { cmplsTeStdExtMIBGroups 9 } -- OBJECT-GROUP -- Status -- mandatory -- Descr -- This contains the MPLS TE extended traps objects related to BFD -- over TE LSP. -- objects -- cmplsTeFailReasonType, cmplsTeFailReasonRev cmplsTeStdExtMIBTrapGroup OBJECT IDENTIFIER ::= { cmplsTeStdExtMIBGroups 5 } -- NOTIFICATION-GROUP -- Status -- mandatory -- Descr -- This contains the MPLS TE extended traps. -- notifications -- cmplsTunnelPreempt, cmplsTunnelInsuffBW, -- cmplsTunnelReRoutePending, cmplsTunnelReRoutePendingClear cmplsTeStdExtMIBFailTeTrapGroup OBJECT IDENTIFIER ::= { cmplsTeStdExtMIBGroups 6 } -- NOTIFICATION-GROUP -- Status -- mandatory -- Descr -- This contains the MPLS TE extended traps related to BFD over -- TE LSP. -- notifications -- cmplsTunnelBringupFail cmplsTeStdExtMIBCompliance OBJECT IDENTIFIER ::= { cmplsTeStdExtMIBCompliances 1 } -- MODULE-COMPLIANCE -- Status -- deprecated -- Descr -- This is the main compliance statement for the MIB. -- Module -- >>current<< -- OptGroup -- cmplsTeStdExtMIBAutoBWOptionalGroup -- OptGroup -- cmplsTeStdExtMIBAutoBWObjectGroup cmplsTeStdExtMIBCompliancesRev1 OBJECT IDENTIFIER ::= { cmplsTeStdExtMIBCompliances 2 } -- MODULE-COMPLIANCE -- Status -- deprecated -- Descr -- This is the main compliance statement for the MIB. -- Adding the extended traps. -- Module -- >>current<< -- OptGroup -- cmplsTeStdExtMIBAutoBWOptionalGroup -- OptGroup -- cmplsTeStdExtMIBAutoBWObjectGroup -- OptGroup -- cmplsTeStdExtMIBTrapGroup -- OptGroup -- cmplsTeStdExtMIBTrapObjectsGroup cmplsTeStdExtMIBComplianceRev2 OBJECT IDENTIFIER ::= { cmplsTeStdExtMIBCompliances 3 } -- MODULE-COMPLIANCE -- Status -- deprecated -- Descr -- This is the main compliance statement for the MIB -- Module -- >>current<< -- OptGroup -- cmplsTeStdExtMIBAutoBWOptionalGroup -- OptGroup -- cmplsTeStdExtMIBAutoBWObjectGroup -- OptGroup -- cmplsTeStdExtMIBTrapGroup -- OptGroup -- cmplsTeStdExtMIBTrapObjectsGroupRev1 cmplsTeStdExtMIBComplianceRev3 OBJECT IDENTIFIER ::= { cmplsTeStdExtMIBCompliances 4 } -- MODULE-COMPLIANCE -- Status -- deprecated -- Descr -- This is the main compliance statement for the MIB -- Module -- >>current<< -- OptGroup -- cmplsTeStdExtMIBAutoBWOptionalGroup -- OptGroup -- cmplsTeStdExtMIBAutoBWObjectGroup -- OptGroup -- cmplsTeStdExtMIBTrapGroup -- OptGroup -- cmplsTeStdExtMIBTrapObjectsGroupRev1 -- OptGroup -- cmplsTeStdExtMIBFailTeTrapGroup -- OptGroup -- cmplsTeStdExtMIBFailTeTrapObjectsGroup cmplsTeStdExtMIBComplianceRev4 OBJECT IDENTIFIER ::= { cmplsTeStdExtMIBCompliances 5 } -- MODULE-COMPLIANCE -- Status -- mandatory -- Descr -- This is the main compliance statement for the MIB -- Module -- >>current<< -- OptGroup -- cmplsTeStdExtMIBAutoBWOptionalGroup -- OptGroup -- cmplsTeStdExtMIBAutoBWObjectGroup -- OptGroup -- cmplsTeStdExtMIBTrapGroup -- OptGroup -- cmplsTeStdExtMIBTrapObjectsGroupRev1 -- OptGroup -- cmplsTeStdExtMIBFailTeTrapGroup -- OptGroup -- cmplsTeStdExtMIBFailTeTrapObjectsGroupRev1 -- ObjVar -- cmplsTeFailReasonType -- OptGroup -- cmplsTeStdExtMIBLoadShareObjectsGroup END