-- MIB file created 24-Feb-2006 09:56:35, by -- SMICng version 2.2.11-beta(PRO)(Solaris), January 20, 2001. Enterprise key cisco.com CISCO-OAM-MIB DEFINITIONS ::= BEGIN -- From file: "CISCO-OAM-MIB.my" -- Compile options "4 7 F H N O W 03 06 0B 0G 0N 0T" IMPORTS TimeStamp, TruthValue, RowStatus FROM SNMPv2-TC-v1 ifIndex FROM IF-MIB OwnerString FROM RMON-MIB ciscoExperiment FROM CISCO-SMI Counter, Gauge FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212 TRAP-TYPE FROM RFC-1215; ciscoOamPingMIB OBJECT IDENTIFIER ::= { ciscoExperiment 15 } -- MODULE-IDENTITY -- LastUpdated -- 200602170000Z -- OrgName -- Cisco Systems, Inc. -- ContactInfo -- Cisco Systems -- Customer Service -- -- Postal: 170 W Tasman Drive -- San Jose, CA 95134 -- USA -- -- Tel: +1 800 553-NETS -- -- E-mail: cs-atm@cisco.com -- Descr -- A MIB module for invoking OAM loopback Ping on ATM -- connections. -- RevDate -- 200602170000Z -- RevDescr -- Removed the OwnerString TEXTUAL-CONVENTION and -- imported the same from RMON-MIB. -- RevDate -- 200306270000Z -- RevDescr -- Add object to oamLoopbackPingTable: -- - oamLoopbackPingMinRttuSec, -- - oamLoopbackPingAvgRttuSec, -- - oamLoopbackPingMaxRttuSec. -- RevDate -- 200304040000Z -- RevDescr -- Add objects to oamLoopbackPingTable: -- - oamLoopbackPingExecTime, -- - oamLoopbackPingDir, -- - oamLoopbackPingOperStatus -- -- Add new table oamLoopbackSegEndPointTable for OAM segment -- endpoint provisioning. -- -- Usage of oamLoopbackSegEndPointTable: -- If the loopback ping test type (oamLoopbackPingType) is -- 'segment', the test requires the endpoint under test -- and the remote ping endpoint are both OAM segment -- loopback endpoints. -- -- The table oamLoopbackSegEndPointTable is used to -- provision an ATM connection endpoint to be an OAM -- segment endpoint. -- -- If the endpoints are already OAM segment endpoints, the -- provisioning of the table is not required. -- RevDate -- 9605010000Z -- RevDescr -- Initial version of the MIB. ciscoOamPingMIBObjects OBJECT IDENTIFIER ::= { ciscoOamPingMIB 1 } oamLoopbackPingMIBTrapPrefix OBJECT IDENTIFIER ::= { ciscoOamPingMIB 2 } oamLoopbackPingMIBTraps OBJECT IDENTIFIER ::= { oamLoopbackPingMIBTrapPrefix 0 } ciscoOamPingMIBConformance OBJECT IDENTIFIER ::= { ciscoOamPingMIB 3 } ciscoOamPingMIBCompliances OBJECT IDENTIFIER ::= { ciscoOamPingMIBConformance 1 } ciscoOamPingMIBGroups OBJECT IDENTIFIER ::= { ciscoOamPingMIBConformance 2 } CiscoOAMPingDir ::= INTEGER { forward(1), backward(2) } -- TEXTUAL-CONVENTION -- Status -- mandatory -- Descr -- Direction in which the OAM segment cells are sent: -- forward : send OAM loopback cells in the -- direction form the originator towards the -- destination of the connection. -- backward : send OAM loopback cells in the direction -- towards the originator of the connection. CiscoOAMPingStatus ::= INTEGER { success(1), timeOut(2), resourceNotAvailable(3), aborted(4), inProgress(5), noResponseData(6), failToStart(7) } -- TEXTUAL-CONVENTION -- Status -- mandatory -- Descr -- Defines possible test status. -- success(1) - The test has completed. -- -- timeOut(2) - The test has been failed because -- the test does not receive loopback -- cell response from remote endpoint -- and it times out. -- -- resourceNotAvailable(3) - The resources required by the -- test is not available, such as other -- application is testing on the same -- endpoint. -- -- aborted(4) - The test is aborted due to the removal -- of connection endpoint or failed to -- proceed. -- -- inProgress(5) - The endpoint is still in progress of -- testing and waiting for the response. -- -- noResponseData(6) - If the test receives response from -- the remote end but without any data. -- -- failToStart(7) - The test fails to kickoff (internal -- messaging timeout). oamLoopbackPingTable OBJECT-TYPE SYNTAX SEQUENCE OF OamLoopbackPingEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of OAM loopback request entries. (This table is similar to the CISCO-PING-MIB.)" ::= { ciscoOamPingMIBObjects 1 } oamLoopbackPingEntry OBJECT-TYPE SYNTAX OamLoopbackPingEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A OAM loopback request entry. A management station wishing to create an entry should first generate a pseudo-random serial number to be used as the index to this sparse table. The NMS should then create the associated instance of the row status and row owner objects. It must also, either in the same or in successive PDUs, create the associated instances specifying the VPI and VCI values. It should also modify the default values for the other configuration objects if the defaults are not appropriate. Once the appropriate instance of all the configuration objects have been created, either by an explicit SNMP set request or by default, the row status should be set to active to initiate the request. Note that this entire procedure may be initiated via a single set request which specifies a row status of createAndGo as well as specifies valid values for the non-defaulted configuration objects. Once the OAM sequence has been activated, it cannot be stopped -- it will run until the configured number of cells have been sent. Once the sequence completes, the management station should retrieve the values of the status objects of interest, and should then delete the entry. In order to prevent old entries from clogging the table, entries will be aged out, but an entry will never be deleted within 5 minutes of completing." INDEX { oamLoopbackPingSerialNumber } ::= { oamLoopbackPingTable 1 } OamLoopbackPingEntry ::= SEQUENCE { oamLoopbackPingSerialNumber INTEGER, oamLoopbackPingInterface INTEGER, oamLoopbackPingVpi INTEGER, oamLoopbackPingVci INTEGER, oamLoopbackPingType INTEGER, oamLoopbackPingLocation OCTET STRING, oamLoopbackPingLocationFlag INTEGER, oamLoopbackPingCount INTEGER, oamLoopbackPingTimeout INTEGER, oamLoopbackPingDelay INTEGER, oamLoopbackPingTrapOnCompletion TruthValue, oamLoopbackPingSentCells Counter, oamLoopbackPingReceivedCells Counter, oamLoopbackPingMinRtt INTEGER, oamLoopbackPingAvgRtt INTEGER, oamLoopbackPingMaxRtt INTEGER, oamLoopbackPingCompleted TruthValue, oamLoopbackPingEntryOwner OwnerString, oamLoopbackPingEntryStatus RowStatus, oamLoopbackPingDir CiscoOAMPingDir, oamLoopbackPingOperStatus CiscoOAMPingStatus, oamLoopbackPingExecTime TimeStamp, oamLoopbackPingMinRttuSec INTEGER, oamLoopbackPingAvgRttuSec INTEGER, oamLoopbackPingMaxRttuSec INTEGER } oamLoopbackPingSerialNumber OBJECT-TYPE SYNTAX INTEGER(1..2147483647) ACCESS not-accessible STATUS mandatory DESCRIPTION "Object which identifies a unique entry in the oamLoopbackPingTable. A management station wishing to initiate a OAM-loopback operation should use a pseudo-random value for this object when creating or modifying an instance of an oamLoopbackPingEntry. The RowStatus semantics of the oamLoopbackPingEntryStatus object will prevent access conflicts." ::= { oamLoopbackPingEntry 1 } oamLoopbackPingInterface OBJECT-TYPE SYNTAX INTEGER(1..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "The interface of the connection on which OAM loopbacks are to be sent. Once an instance of this object is created, its value can not be changed. The value specified for this object must equate to a value of ifIndex in the ifTable." ::= { oamLoopbackPingEntry 2 } oamLoopbackPingVpi OBJECT-TYPE SYNTAX INTEGER(0..4095) ACCESS read-write STATUS mandatory DESCRIPTION "The VPI of the connection on which OAM loopbacks are to be sent. Once an instance of this object is created, its value can not be changed." ::= { oamLoopbackPingEntry 3 } oamLoopbackPingVci OBJECT-TYPE SYNTAX INTEGER(-1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Either -1 or the VCI of the connection on which F5 OAM loopback cells are to be sent. If the value of this object is -1, then an F4 OAM loopback cells will be sent on the VPC indicated by oamLoopbackPingVpi. An instance of this object cannot be created until the associated instance of oamLoopbackPingVpi is created. Once an instance of this object is created, its value can not be changed." ::= { oamLoopbackPingEntry 4 } oamLoopbackPingType OBJECT-TYPE SYNTAX INTEGER { segment(1), end2end(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The type of OAM loopback to be performed." DEFVAL { end2end } ::= { oamLoopbackPingEntry 5 } oamLoopbackPingLocation OBJECT-TYPE SYNTAX OCTET STRING(SIZE(0..16)) ACCESS read-write STATUS mandatory DESCRIPTION "The value to be placed in the 'Loopback Location ID' field of the OAM loopback cell. If this value is less than 16 octets in length, then it will be appended with zero-valued octets to form the required 96-bit value. One possibility is to set this value to the IP-address of the node at which the OAM loopback is to occur. An instance of this object cannot be created until the associated instance of oamLoopbackPingVpi is created. Once an instance of this object is created, its value can not be changed." DEFVAL { 'FF'H } ::= { oamLoopbackPingEntry 6 } oamLoopbackPingLocationFlag OBJECT-TYPE SYNTAX INTEGER { ipAddress(1), nsapPrefix(2), fixed16byteValue(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Specifies what kind of information is embedded into the oamLoopbackPingLocation string. This flag is ignored when oamLoopbackPingType is set to segment." DEFVAL { ipAddress } ::= { oamLoopbackPingEntry 7 } oamLoopbackPingCount OBJECT-TYPE SYNTAX INTEGER(0..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the number of OAM loopback cells to send to the target in this sequence." DEFVAL { 5 } ::= { oamLoopbackPingEntry 8 } oamLoopbackPingTimeout OBJECT-TYPE SYNTAX INTEGER(0..3600000) -- Units -- milliseconds ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the amount of time to wait for a response to a transmitted OAM loopback cells before declaring the OAM loopback cells as 'dropped.'" DEFVAL { 1000 } ::= { oamLoopbackPingEntry 9 } oamLoopbackPingDelay OBJECT-TYPE SYNTAX INTEGER(0..3600000) -- Units -- milliseconds ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the minimum amount of time to wait before sending the next OAM loopback cell in a sequence after receiving a response or declaring a timeout for a previous OAM cell. The actual delay may be greater due to internal task scheduling." DEFVAL { 0 } ::= { oamLoopbackPingEntry 10 } oamLoopbackPingTrapOnCompletion OBJECT-TYPE SYNTAX TruthValue -- Rsyntax INTEGER { -- true(1), -- false(2) -- } ACCESS read-write STATUS mandatory DESCRIPTION "Specifies whether or not a oamLoopbackPingCompletion trap should be issued on completion of the sequence of OAM loopback cells. If such a trap is desired, it is the responsibility of the management entity to ensure that the SNMP administrative model is configured in such a way as to allow the trap to be delivered." DEFVAL { false } ::= { oamLoopbackPingEntry 11 } oamLoopbackPingSentCells OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of OAM loopback cells that have been sent to the target in this sequence." ::= { oamLoopbackPingEntry 12 } oamLoopbackPingReceivedCells OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of OAM loopback cells that have been received from the target in this sequence." ::= { oamLoopbackPingEntry 13 } oamLoopbackPingMinRtt OBJECT-TYPE SYNTAX INTEGER(0..2147483647) -- Units -- milliseconds ACCESS read-only STATUS mandatory DESCRIPTION "The minimum round trip time of all the OAM loopback cells that have been sent in this sequence. This object will not be created until the first OAM loopback response in a sequence is received." ::= { oamLoopbackPingEntry 14 } oamLoopbackPingAvgRtt OBJECT-TYPE SYNTAX INTEGER(0..2147483647) -- Units -- milliseconds ACCESS read-only STATUS mandatory DESCRIPTION "The average round trip time of all the OAM loopback cells that have been sent in this sequence. This object will not be created until the first OAM loopback response in a sequence is received." ::= { oamLoopbackPingEntry 15 } oamLoopbackPingMaxRtt OBJECT-TYPE SYNTAX INTEGER(0..2147483647) -- Units -- milliseconds ACCESS read-only STATUS mandatory DESCRIPTION "The maximum round trip time of all the OAM loopback cells that have been sent in this sequence. This object will not be created until the first OAM loopback response in a sequence is received." ::= { oamLoopbackPingEntry 16 } oamLoopbackPingCompleted OBJECT-TYPE SYNTAX TruthValue -- Rsyntax INTEGER { -- true(1), -- false(2) -- } ACCESS read-only STATUS mandatory DESCRIPTION "Set to true when all the OAM loopback cells in this sequence have been either responded to or timed out." ::= { oamLoopbackPingEntry 17 } oamLoopbackPingEntryOwner OBJECT-TYPE SYNTAX OwnerString -- Rsyntax OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "The entity that configured this entry." ::= { oamLoopbackPingEntry 18 } oamLoopbackPingEntryStatus OBJECT-TYPE SYNTAX RowStatus -- Rsyntax INTEGER { -- active(1), -- notInService(2), -- notReady(3), -- createAndGo(4), -- createAndWait(5), -- destroy(6) -- } ACCESS read-write STATUS mandatory DESCRIPTION "The status of this table entry. Once the entry status is set to active, the associate entry cannot be modified until the sequence completes (oamLoopbackPingCompleted is true)." ::= { oamLoopbackPingEntry 19 } oamLoopbackPingDir OBJECT-TYPE SYNTAX CiscoOAMPingDir -- Rsyntax INTEGER { -- forward(1), -- backward(2) -- } ACCESS read-write STATUS mandatory DESCRIPTION "This object set the traveling direction of the OAM segment loopback cells which are injected to the connection endpoint." ::= { oamLoopbackPingEntry 20 } oamLoopbackPingOperStatus OBJECT-TYPE SYNTAX CiscoOAMPingStatus -- Rsyntax INTEGER { -- success(1), -- timeOut(2), -- resourceNotAvailable(3), -- aborted(4), -- inProgress(5), -- noResponseData(6), -- failToStart(7) -- } ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the ping test status." ::= { oamLoopbackPingEntry 21 } oamLoopbackPingExecTime OBJECT-TYPE SYNTAX TimeStamp -- Rsyntax TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "The value of sysUpTime when the MIB object is created which triggers the loppback ping test." ::= { oamLoopbackPingEntry 22 } oamLoopbackPingMinRttuSec OBJECT-TYPE SYNTAX INTEGER(0..2147483647) -- Units -- microseconds ACCESS read-only STATUS mandatory DESCRIPTION "The minimum round trip time of all the OAM loopback cells that have been sent in this sequence. This object will not be created until the first OAM loopback response in a sequence is received. Notes: this object is the same as oamLoopbackPingMinRtt but the unit is in microseconds instead of milliseconds." ::= { oamLoopbackPingEntry 23 } oamLoopbackPingAvgRttuSec OBJECT-TYPE SYNTAX INTEGER(0..2147483647) -- Units -- microseconds ACCESS read-only STATUS mandatory DESCRIPTION "The average round trip time of all the OAM loopback cells that have been sent in this sequence. This object will not be created until the first OAM loopback response in a sequence is received. Notes: this object is the same as oamLoopbackPingAvgRtt but the unit is in microseconds instead of milliseconds." ::= { oamLoopbackPingEntry 24 } oamLoopbackPingMaxRttuSec OBJECT-TYPE SYNTAX INTEGER(0..2147483647) -- Units -- microseconds ACCESS read-only STATUS mandatory DESCRIPTION "The maximum round trip time of all the OAM loopback cells that have been sent in this sequence. This object will not be created until the first OAM loopback response in a sequence is received. Notes: this object is the same as oamLoopbackPingMaxRtt but the unit is in microseconds instead of milliseconds." ::= { oamLoopbackPingEntry 25 } oamLoopbackSegEndPointTable OBJECT-TYPE SYNTAX SEQUENCE OF OamLoopbackSegEndPointEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains a list of OAM loopback segment endpoints. When the endpoint is an OAM segment endpoint, it is able to send ATM segment loop back cells or loop back the cells to the originator which initiates the OAM loop back ping test. The provisioning of this table is required if the loopback ping test type (oamLoopbackPingType) in oamLoopbackPingTable is 'segment', and the endpoint under test or the remote ping endpoint is not OAM segment loopback endpoints." ::= { ciscoOamPingMIBObjects 2 } oamLoopbackSegEndPointEntry OBJECT-TYPE SYNTAX OamLoopbackSegEndPointEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the segment endpoint table." INDEX { ifIndex, oamLoopSegVpi, oamLoopSegVci } ::= { oamLoopbackSegEndPointTable 1 } OamLoopbackSegEndPointEntry ::= SEQUENCE { oamLoopSegVpi Gauge, oamLoopSegVci Gauge, oamLoopSegRowStatus RowStatus } oamLoopSegVpi OBJECT-TYPE SYNTAX Gauge(0..4095) ACCESS not-accessible STATUS mandatory DESCRIPTION "The VPI value of a VP or VC connection." ::= { oamLoopbackSegEndPointEntry 1 } oamLoopSegVci OBJECT-TYPE SYNTAX Gauge(0..65535) ACCESS not-accessible STATUS mandatory DESCRIPTION "The VCI value of VC connection. For a VPC connection, the VCI value is 0." ::= { oamLoopbackSegEndPointEntry 2 } oamLoopSegRowStatus OBJECT-TYPE SYNTAX RowStatus -- Rsyntax INTEGER { -- active(1), -- notInService(2), -- notReady(3), -- createAndGo(4), -- createAndWait(5), -- destroy(6) -- } ACCESS read-write STATUS mandatory DESCRIPTION "To create, delete an OAM segment entry. Only the value 'active', 'createAndGo', and 'destroy' are supported. If the connection endpoint does not exist, the entry could not be created. If the associated ATM connection is de-routed or deleted, the connection endpoint is gone. The associated row entry will be removed automatically." ::= { oamLoopbackSegEndPointEntry 3 } oamLoopbackPingCompletionTrap TRAP-TYPE -- Reverse mappable trap ENTERPRISE oamLoopbackPingMIBTrapPrefix VARIABLES { oamLoopbackPingCompleted } -- Status -- mandatory DESCRIPTION "A oamLoopbackPingCompleted trap is sent at the completion of a sequence of OAM loopback cells if such a trap was requested when the sequence was initiated." ::= 1 ciscoOamPingMIBGroup OBJECT IDENTIFIER ::= { ciscoOamPingMIBGroups 1 } -- OBJECT-GROUP -- Status -- deprecated -- Descr -- A collection of objects providing the ability to invoke -- the sending of OAM loopback cells. -- objects -- oamLoopbackPingInterface, oamLoopbackPingVpi, -- oamLoopbackPingVci, oamLoopbackPingCount, oamLoopbackPingType, -- oamLoopbackPingLocation, oamLoopbackPingLocationFlag, -- oamLoopbackPingTimeout, oamLoopbackPingDelay, -- oamLoopbackPingTrapOnCompletion, oamLoopbackPingSentCells, -- oamLoopbackPingReceivedCells, oamLoopbackPingMinRtt, -- oamLoopbackPingAvgRtt, oamLoopbackPingMaxRtt, -- oamLoopbackPingCompleted, oamLoopbackPingEntryOwner, -- oamLoopbackPingEntryStatus ciscoOamPing2MIBGroup OBJECT IDENTIFIER ::= { ciscoOamPingMIBGroups 2 } -- OBJECT-GROUP -- Status -- deprecated -- Descr -- A collection of objects providing the ability to invoke -- the sending of OAM loopback cells. -- objects -- oamLoopbackPingInterface, oamLoopbackPingVpi, -- oamLoopbackPingVci, oamLoopbackPingCount, oamLoopbackPingType, -- oamLoopbackPingLocation, oamLoopbackPingLocationFlag, -- oamLoopbackPingTimeout, oamLoopbackPingDelay, -- oamLoopbackPingTrapOnCompletion, oamLoopbackPingSentCells, -- oamLoopbackPingReceivedCells, oamLoopbackPingMinRtt, -- oamLoopbackPingAvgRtt, oamLoopbackPingMaxRtt, -- oamLoopbackPingCompleted, oamLoopbackPingEntryOwner, -- oamLoopbackPingEntryStatus, oamLoopbackPingDir, -- oamLoopbackPingOperStatus, oamLoopbackPingExecTime ciscoOamPingSegEndPointGroup OBJECT IDENTIFIER ::= { ciscoOamPingMIBGroups 3 } -- OBJECT-GROUP -- Status -- mandatory -- Descr -- A collection of objects providing the ability to provision -- ATM connection endpoints to be OAM segment loopback endpoint. -- objects -- oamLoopSegRowStatus ciscoOamPingMIBGroupRev3 OBJECT IDENTIFIER ::= { ciscoOamPingMIBGroups 5 } -- OBJECT-GROUP -- Status -- mandatory -- Descr -- A collection of objects providing the ability to invoke -- the sending of OAM loopback cells. -- objects -- oamLoopbackPingInterface, oamLoopbackPingVpi, -- oamLoopbackPingVci, oamLoopbackPingCount, oamLoopbackPingType, -- oamLoopbackPingLocation, oamLoopbackPingLocationFlag, -- oamLoopbackPingTimeout, oamLoopbackPingDelay, -- oamLoopbackPingTrapOnCompletion, oamLoopbackPingSentCells, -- oamLoopbackPingReceivedCells, oamLoopbackPingMinRtt, -- oamLoopbackPingAvgRtt, oamLoopbackPingMaxRtt, -- oamLoopbackPingCompleted, oamLoopbackPingEntryOwner, -- oamLoopbackPingEntryStatus, oamLoopbackPingDir, -- oamLoopbackPingOperStatus, oamLoopbackPingExecTime, -- oamLoopbackPingAvgRttuSec, oamLoopbackPingMinRttuSec, -- oamLoopbackPingMaxRttuSec oamLoopbackNotificationsGroup OBJECT IDENTIFIER ::= { ciscoOamPingMIBGroups 4 } -- NOTIFICATION-GROUP -- Status -- mandatory -- Descr -- A collection of notifications for OAM loopback ping test. -- notifications -- oamLoopbackPingCompletionTrap ciscoOamPingMIBCompliance OBJECT IDENTIFIER ::= { ciscoOamPingMIBCompliances 1 } -- MODULE-COMPLIANCE -- Status -- deprecated -- Descr -- The compliance statement for the Cisco OAM MIB. -- Module -- >>current<< -- MandGroup -- ciscoOamPingMIBGroup ciscoOamPingMIBCompliance2 OBJECT IDENTIFIER ::= { ciscoOamPingMIBCompliances 2 } -- MODULE-COMPLIANCE -- Status -- deprecated -- Descr -- The compliance statement for the Cisco OAM MIB. -- Module -- >>current<< -- MandGroup -- ciscoOamPing2MIBGroup -- MandGroup -- oamLoopbackNotificationsGroup -- OptGroup -- ciscoOamPingSegEndPointGroup ciscoOamPingMIBCompliance3 OBJECT IDENTIFIER ::= { ciscoOamPingMIBCompliances 3 } -- MODULE-COMPLIANCE -- Status -- mandatory -- Descr -- The compliance statement for the Cisco OAM MIB. -- Module -- >>current<< -- MandGroup -- ciscoOamPingMIBGroupRev3 -- MandGroup -- oamLoopbackNotificationsGroup -- OptGroup -- ciscoOamPingSegEndPointGroup END