-- MIB file created 12-Sep-2004 09:41:07, by -- SMICng version 2.2.11-beta(PRO)(Solaris), January 20, 2001. Enterprise key cisco.com CISCO-SONET-MIB DEFINITIONS ::= BEGIN -- From file: "CISCO-SONET-MIB.my" -- Compile options "4 7 F H N W 03 06 0B 0G 0N 0T" IMPORTS TruthValue FROM SNMPv2-TC-v1 InterfaceIndex, ifIndex, ifDescr FROM IF-MIB ciscoMgmt FROM CISCO-SMI --?? may need import of ifIndex from RFC1213-MIB sonetSectionCurrentStatus, sonetLineCurrentStatus, sonetPathCurrentStatus, sonetVTCurrentStatus FROM SONET-MIB Counter, Gauge FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212 TRAP-TYPE FROM RFC-1215; ciscoSonetMIB OBJECT IDENTIFIER ::= { ciscoMgmt 126 } -- MODULE-IDENTITY -- LastUpdated -- 200303070000Z -- OrgName -- Cisco Systems, Inc. -- ContactInfo -- Cisco Systems -- Customer Service -- -- Postal: 170 W Tasman Drive -- San Jose, CA 95134 -- USA -- -- Tel: +1 800 553-NETS -- -- E-mail: cs-wanatm@cisco.com -- Descr -- The MIB module to describe SONET/SDH interfaces -- objects. This is an extension to the standard SONET -- MIB(RFC 2558). -- RevDate -- 200303070000Z -- RevDescr -- (1) Added enumerations e3(8) and vtStructured(9) -- in object cspSonetPathPayload. -- (2) Added table csAu4Tug3Config to configure the -- VC(Virtual Container) related properties of a -- TUG-3 within a AU-4 paths. -- RevDate -- 200206140000Z -- RevDescr -- (1)Added following objects to cspConfigTable: -- cspTributaryMappingType -- cspSignallingTransportMode -- cspTributaryGroupingType -- (2)Added an optional ciscoSonetPathConfMIBGroup1 -- for the above objects. -- RevDate -- 200205220000Z -- RevDescr -- (1) Added cspConfigTable which augments -- sonetPathCurrentTable. -- (2) Added the Notifications - -- ciscoSonetSectionStatusChange, -- ciscoSonetLineStatusChange, -- ciscoSonetPathStatusChange, -- ciscoSonetVTStatusChange -- and the object - -- csNotificationsEnabled. -- (3) Changed the Module-Compliance and made -- ciscoSonetStatsMIBGroup and -- ciscoSonetApsMIBGroup1 groups as optional -- RevDate -- 200110170000Z -- RevDescr -- (1) Added CsApsLineFailureCode, -- CsApsLineFailureStatus, and -- CsApsLineSwitchReason TEXTUAL-CONVENTION. -- (2) Added csApsSwitchReason, csApsFailureStatus, -- and csApsPrimarySection columnar objects to -- CsApsConfigEntry. -- (3) Added csApsModeMismatch enumeration to -- CsApsLineFailureCode. -- (4) Added csApsNoSwitch enumeration to -- CsApsLineSwitchReason. -- (5) Changed descriptions for csApsWorkingIndex, -- and csApsProtectionIndex specifically related -- to ITU G.783 AnnexB protocol support. -- (6) Add objects csConfigRDIVType and csConfigRDIPType in table -- csConfigTable. -- (7) Add enum sonetSts3(9) for obj csConfigType. -- (8) Add table csVTConfigTable augmenting the table csConfigTable. -- The table csVTVonfigTable contains the following objects: -- csTributaryType -- csTributaryMappingType -- csTributaryFramingType -- csSignallingTransportMode -- csTributaryGroupingType -- RevDate -- 200007120000Z -- RevDescr -- Made following changes -- -- (1) Added enumeration csApsNone(3) to -- csApsActiveLine object and updated the -- description. -- (2) Added enumerations sonetSts192c(7) and -- sonetStm64(8) to csConfigType object and -- updated the descripton. -- (3) Fixed description of csConfigType object. -- RevDate -- 9903080000Z -- RevDescr -- Initial version of the MIB. ciscoSonetMIBNotifs OBJECT IDENTIFIER ::= { ciscoSonetMIB 0 } ciscoSonetMIBObjects OBJECT IDENTIFIER ::= { ciscoSonetMIB 1 } csConfig OBJECT IDENTIFIER ::= { ciscoSonetMIBObjects 1 } csApsConfig OBJECT IDENTIFIER ::= { ciscoSonetMIBObjects 2 } csSection OBJECT IDENTIFIER ::= { ciscoSonetMIBObjects 3 } csLine OBJECT IDENTIFIER ::= { ciscoSonetMIBObjects 4 } csPath OBJECT IDENTIFIER ::= { ciscoSonetMIBObjects 5 } csStats OBJECT IDENTIFIER ::= { ciscoSonetMIBObjects 6 } cspConfig OBJECT IDENTIFIER ::= { ciscoSonetMIBObjects 7 } csNotifications OBJECT IDENTIFIER ::= { ciscoSonetMIBObjects 8 } csAu4Tug3Config OBJECT IDENTIFIER ::= { ciscoSonetMIBObjects 9 } ciscoSonetMIBConformance OBJECT IDENTIFIER ::= { ciscoSonetMIB 3 } ciscoSonetMIBCompliances OBJECT IDENTIFIER ::= { ciscoSonetMIBConformance 1 } ciscoSonetMIBGroups OBJECT IDENTIFIER ::= { ciscoSonetMIBConformance 2 } CsApsLineFailureCode ::= INTEGER { csApsChannelMismatch(1), csApsProtectionByteFail(2), csApsFEProtectionFailure(3), csApsModeMismatch(4) } -- TEXTUAL-CONVENTION -- Status -- mandatory -- Descr -- The Sonet APS line failure code - this is the failure -- encountered by the APS line. -- -- csApsChannelMismatch: Transmitted K1 byte and -- received K2 byte do not match. -- csApsProtectionByteFail: It could mean either K1 byte -- with invalid type of switch -- request bits was received, or, -- priority of received K1 byte -- is lower than the transmitted -- K1 byte. -- csApsFEProtectionFailure: Remote end error detected. -- csApsModeMismatch: APS architecture mode mismatch. CsApsLineFailureStatus ::= OCTET STRING(SIZE(1..2)) -- BITS are: -- noApsLineFailure(0) -- csApsChannelMismatchBit(1) -- csApsProtectionByteFailBit(2) -- csApsFEProtectionFailureBit(3) -- csApsModeMismatchBit(4) -- TEXTUAL-CONVENTION -- Status -- mandatory -- Descr -- The indication of the APS line failure status with a bit -- map representing multiple failures. -- -- noApsLineFailure bit indicates current failure status. -- This bit should be set ONLY if no other bit is set. -- -- csApsChannelMismatchBit is set when the APS line is in -- csApsChannelMismatch. -- -- csApsProtectionByteFailBit is set when the APS line is -- in csApsProtectionByteFail failure code. -- -- csApsFEProtectionFailureBit is set when the APS line is -- in csApsFEProtectionFailure. -- -- csApsModeMismatchBit is set when the APS line is in -- csApsModeMismatch. CsApsLineSwitchReason ::= INTEGER { csApsOther(1), csApsRevertive(2), csApsManual(3), csApsSignalDefectLow(4), csApsSignalDefectHigh(5), csApsSignalFailureLow(6), csApsSignalFailureHigh(7), csApsForceSwitch(8), csApsLockOut(9), csApsNoSwitch(10) } -- TEXTUAL-CONVENTION -- Status -- mandatory -- Descr -- The reason why APS switch happened. When the working -- line on one end fails, its other end is told to do -- an APS switch. The following options in the increasing -- order of priority indicate what type of switch request -- it is. -- -- csApsRevertive : Switch back to working line after the -- Wait-to-Restore interval is over, and failures are -- cleared. It is the lowest priority. -- csApsManual : Manual switch causes APS switch unless a -- request of equal or higher priority is in effect. -- csApsSignalDefectLow : Switch happened because threshold -- for 'csApsSigFaultBER' was exceeded. -- csApsSignalDefectHigh : Same as above, but higher priority. -- csApsSignalFailureLow : Switch happened because threshold -- for 'csApsSigDegradeBER' was exceeded. -- csApsSignalFailureHigh : Same as above, but higher -- priority. -- csApsForceSwitch : Forced switch forces hardware to switch -- the active line even if the other line (could be -- working line or protection line) is in alarm. -- csApsLockOut : This is the highest priority switch. This -- will override all other requests. -- csApsNoSwitch : This is a state when no switch happens. csConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF CsConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The SONET/SDH configuration table. This table has objects for configuring sonet lines." ::= { csConfig 1 } csConfigEntry OBJECT-TYPE SYNTAX CsConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the table. There is an entry for each SONET line in the table. Entries are automatically created for an ifType value of sonet(39). 'ifAdminStatus' from the ifTable must be used to enable or disable a line. A line is in disabled(down) state unless provisioned 'up' using 'ifAdminStatus'." INDEX { ifIndex } ::= { csConfigTable 1 } CsConfigEntry ::= SEQUENCE { csConfigLoopbackType INTEGER, csConfigXmtClockSource INTEGER, csConfigFrameScramble INTEGER, csConfigType INTEGER, csConfigRDIVType INTEGER, csConfigRDIPType INTEGER } csConfigLoopbackType OBJECT-TYPE SYNTAX INTEGER { noLoopback(1), lineLocal(2), lineRemote(3) } ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies the desired loopback mode configuration of the SONET line. The possible values of this objects are follows: noLoopback : Not in the loopback state. lineLocal : The signal transmitted from this interface is connected to the associated incoming receiver. This ensures that the SONET frame transmitted from the interface is received back at the interface. lineRemote : The signal received at the interface is looped back out to the associated transmitter. This ensures that the remote equipment that originated the signal receives it back. The signal may undergo degradation as a result of the characteristics of the transmission medium." DEFVAL { noLoopback } ::= { csConfigEntry 1 } csConfigXmtClockSource OBJECT-TYPE SYNTAX INTEGER { loopTiming(1), localTiming(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the source of the transmit clock. loopTiming: indicates that the recovered receive clock is used as the transmit clock. localTiming: indicates that a local clock source is used or that an external clock is attached to the box containing the interface. " DEFVAL { localTiming } ::= { csConfigEntry 2 } csConfigFrameScramble OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This object is used to disable or enable the Scrambling option in SONET line." REFERENCE "GR-253-CORE Issue 3, September 2000: Section 5.1.3." DEFVAL { enabled } ::= { csConfigEntry 3 } csConfigType OBJECT-TYPE SYNTAX INTEGER { sonetSts3c(1), sonetStm1(2), sonetSts12c(3), sonetStm4(4), sonetSts48c(5), sonetStm16(6), sonetSts192c(7), sonetStm64(8), sonetSts3(9) } ACCESS read-only STATUS mandatory DESCRIPTION "This object represents the configured line type. Sts is SONET format. Stm is SDH format. sonetSts3c : OC3 concatenated sonetStm1 : European standard OC3 sonetSts12c : OC12 concatenated sonetStm4 : European standard OC12 sonetSts48c : OC48 concatenated sonetStm16 : European standard OC48 sonetSts192c : OC-192 concatenated sonetStm64 : European standard OC-192 sonetSts3 : OC3 (unconcatenated) " ::= { csConfigEntry 4 } csConfigRDIVType OBJECT-TYPE SYNTAX INTEGER { onebit(1), threebit(3) } ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies the type of RDI-V (Remote Defect Indication - Virtual Tributary/Container) sent by this Network Element (NE) to the remote Network Element. onebit : use 1 bit RDI-V threebit : use 3 bit enhanced RDI-V. Default is onebit." DEFVAL { onebit } ::= { csConfigEntry 5 } csConfigRDIPType OBJECT-TYPE SYNTAX INTEGER { onebit(1), threebit(3) } ACCESS read-write STATUS mandatory DESCRIPTION "This object represents the type of RDI-P (Remote Defect Indication - Path) sent by this Network Element (NE) to remote Network Element. onebit : use 1 bit RDI-P threebit : use 3 bit enhanced RDI-P. Default is onebit." DEFVAL { onebit } ::= { csConfigEntry 6 } csVTConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF CsVTConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains objects to configure the VT/VC (Virtual Tributary / Virtual Container) related properties of SONET/SDH lines." ::= { csConfig 2 } csVTConfigEntry OBJECT-TYPE SYNTAX CsVTConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "There is an entry in this table for each SONET line that supports SONET virtual tributaries or SDH virtual containers. Each entry in this table will have a corresponding entry in csConfigTable." INDEX { ifIndex } -- Augments csConfigEntry ::= { csVTConfigTable 1 } CsVTConfigEntry ::= SEQUENCE { csTributaryType INTEGER, csTributaryMappingType INTEGER, csTributaryFramingType INTEGER, csSignallingTransportMode INTEGER, csTributaryGroupingType INTEGER } csTributaryType OBJECT-TYPE SYNTAX INTEGER { vt15vc11(1), vt2vc12(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Type of the tributary carried within the SONET/SDH signal. vt15vc11 : carries T1 signal vt2vc12 : carries E1 signal" ::= { csVTConfigEntry 1 } csTributaryMappingType OBJECT-TYPE SYNTAX INTEGER { asynchronous(1), byteSynchronous(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This object represents the VT/VC mapping type. asynchronous: In this mode, the channel structure of DS1/E1 is neither visible nor preserved. byteSynchronous: In this mode, the DS0 signals inside the VT/VC can be found and extracted from the frame. Default is asynchronous(1)." ::= { csVTConfigEntry 2 } csTributaryFramingType OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), dsx1D4(2), dsx1ESF(3) } ACCESS read-write STATUS mandatory DESCRIPTION "This object represents the framing type to be assigned to the virtual tributaries in byte sync mapping mode. notApplicable : If VT mapping is not byteSynchronous(2). dsx1ESF : Extended Superframe Format dsx1D4 : Superframe Format Default is dsx1ESF(3) if csTributaryMappingType is byteSynchronous(2). For asynchronous(1) mapping, the default is notApplicable(1). The value notApplicable(1) can not be set." ::= { csVTConfigEntry 3 } csSignallingTransportMode OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), signallingTransferMode(2), clearMode(3) } ACCESS read-write STATUS mandatory DESCRIPTION "This object represents the mode used to transport DS0 signalling information for T1 byteSynchronous mapping (GR253). In signallingTransferMode(2), the robbed-bit signalling is transferred to the VT header. In clearMode(3), only the framing bit is transferred to the VT header. Default is signallingTransferMode(2) if csTributaryMappingType is byteSynchronous. For asynchronous mapping, it is notApplicable(1). The value notApplicable(1) can not be set." ::= { csVTConfigEntry 4 } csTributaryGroupingType OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), au3Grouping(2), au4Grouping(3) } ACCESS read-write STATUS mandatory DESCRIPTION "This object represents the method used to group VCs into an STM-1 signal. Applicable only to SDH. au3Grouping: STM1<-AU-3<-TUG-2<-TU-12<-VC12 or STM1<-AU-3<-TUG-2<-TU-11<-VC11. au4Grouping: STM1<-AU-4<-TUG-3<-TUG-2<-TU-12<-VC12 or STM1<-AU-4<-TUG-3<-TUG-2<-TU-11<-VC11. Default is au3Grouping(2) for SDH and notApplicable(1) for SONET." ::= { csVTConfigEntry 5 } csApsConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF CsApsConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains objects to configure APS (Automatic Protection Switching) feature in a SONET Line. APS is the ability to configure a pair of SONET lines for redundancy so that the hardware will automatically switch the active line from working line to the protection line or vice versa, within 60ms, when the active line fails." ::= { csApsConfig 1 } csApsConfigEntry OBJECT-TYPE SYNTAX CsApsConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry is created when an APS pair is configured. To create an entry, the following objects must be specified: csApsWorkingIndex, csApsProtectionIndex, csApsEnable, csApsArchMode. The protection line must not be active, i.e, ifAdminStatus must be 'down', while configuring APS. An entry is created by setting the value of 'csApsEnable' to csApsEnabled (2) and deleted by setting it to csApsDisabled (1). Once a line is configured as working line or protection line, it remains in that role until APS is disabled on that sonet line pair. It remains in the working/protection role even after the card is reset." INDEX { csApsWorkingIndex } ::= { csApsConfigTable 1 } CsApsConfigEntry ::= SEQUENCE { csApsWorkingIndex InterfaceIndex, csApsProtectionIndex InterfaceIndex, csApsEnable INTEGER, csApsArchMode INTEGER, csApsActiveLine INTEGER, csApsSigFaultBER Gauge, csApsSigDegradeBER Gauge, csApsWaitToRestore Gauge, csApsDirection INTEGER, csApsRevertive INTEGER, csApsDirectionOperational INTEGER, csApsArchModeOperational INTEGER, csApsChannelProtocol INTEGER, csApsFailureStatus CsApsLineFailureStatus, csApsSwitchReason CsApsLineSwitchReason, csApsPrimarySection INTEGER } csApsWorkingIndex OBJECT-TYPE SYNTAX InterfaceIndex -- Rsyntax INTEGER(1..2147483647) ACCESS not-accessible STATUS mandatory DESCRIPTION "When a pair of APS lines is configured, one line has to be the working line, which is the primary line, and the other has to be the protection line, which is the backup line. This object refers to the working line in the APS pair. For G.783 AnnexB, this index refers to Working Section 1." REFERENCE "GR-253-CORE, G.783 AnnexB" ::= { csApsConfigEntry 1 } csApsProtectionIndex OBJECT-TYPE SYNTAX InterfaceIndex -- Rsyntax INTEGER(1..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "The protection line indicates that it will become the active line when an APS switch occurs (APS switch could occur because of a failure on the working line). For G.783 AnnexB, This index refers to Working Section 2." REFERENCE "GR-253-CORE, G.783 AnnexB" ::= { csApsConfigEntry 2 } csApsEnable OBJECT-TYPE SYNTAX INTEGER { csApsDisabled(1), csApsEnabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This object is used to enable or disable the APS feature on the working/protection line pairs. When enabled, the hardware will automatically switch the active line from the working line to the protection line within 60ms, or vice versa." ::= { csApsConfigEntry 3 } csApsArchMode OBJECT-TYPE SYNTAX INTEGER { onePlusOne(1), oneToOne(2), anexBOnePlusOne(3), ycableOnePlusOneNok1k2(4), straightOnePlusOneNok1k2(5) } ACCESS read-write STATUS mandatory DESCRIPTION "This object is used to configure APS architecture mode on the working/protection line pairs. All of the following are supported on single slot. oneToOne(2) is not supported across 2 slots,i.e. the working and protection slot numbers must be the same in oneToOne(2). onePlusOne : This can be supported on the same card and across 2 cards. This mode means that the transmit and receive signals go only over the active line(which could be working or protection line). (straight cable implied) oneToOne : This is supported only on the same card This mode means that the transmit and receive signals go over the working and protection lines. (straight cable implied) anexBOnePlusOne : This can be supported on the same card and across 2 cards. This mode is like the onePlusOne mode, except that the 'csApsDirection' can only be bi-directional. (straight cable implied) ycableOnePlusOneNok1k2: With Y-cable ignore K1K2 bytes. This mode is the Y-cable redundancy mode. straightOnePlusOneNok1k2 : With straight cable, ignore K1K2 bytes. This mode is like onePlusOne, but with K1, K2 bytes ignored." ::= { csApsConfigEntry 4 } csApsActiveLine OBJECT-TYPE SYNTAX INTEGER { csApsWorkingLine(1), csApsProtectionLine(2), csApsNone(3) } ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates which line is currently active. It could be the working line(Section 1 for Annex B), the protection line(Section 2 for Annex B) or none if neither working nor protection line is active. This object reflects the status of receive direction." REFERENCE "GR-253-CORE, G.783 AnnexB" ::= { csApsConfigEntry 5 } csApsSigFaultBER OBJECT-TYPE SYNTAX Gauge(3..5) ACCESS read-write STATUS mandatory DESCRIPTION "This object contains the Bit Error Rate threshold for Signal Fault detection on the working line. Once this threshold is exceeded, an APS switch will occur. This value is 10 to the -n, where n is between 3 and 5." DEFVAL { 3 } ::= { csApsConfigEntry 6 } csApsSigDegradeBER OBJECT-TYPE SYNTAX Gauge(5..9) ACCESS read-write STATUS mandatory DESCRIPTION "This object contains the Bit Error Rate threshold for Signal Degrade detection on the working line. Once this threshold is exceeded, an APS switch will occur. This value is 10 to -n where n is between 5 and 9." DEFVAL { 5 } ::= { csApsConfigEntry 7 } csApsWaitToRestore OBJECT-TYPE SYNTAX Gauge(1..12) -- Units -- minutes ACCESS read-write STATUS mandatory DESCRIPTION "This object contains interval in minutes to wait before attempting to switch back to working line. Not applicable if the line is configured in non-revertive mode, i.e. protection line will continue to be active, even if failures on the working line are cleared. The framer clears the signal-fault and signal-degrade when APS switch occurs. Please refer to 'csApsRevertive' for description of non-revertive." ::= { csApsConfigEntry 8 } csApsDirection OBJECT-TYPE SYNTAX INTEGER { uniDirectional(1), biDirectional(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This object is used to configure the switching direction which this APS line supports. Unidirectional : APS switch only in one direction. Bidirectional : APS switch in both ends of the line." ::= { csApsConfigEntry 9 } csApsRevertive OBJECT-TYPE SYNTAX INTEGER { nonrevertive(1), revertive(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This object is used to configure the APS revertive or nonrevertive option. revertive : Will switch the working line back to active state after the Wait-To-restore interval has expired and the working line Signal-Fault/Signal-Degrade has been cleared. Please refer to 'csApsWaitToRestore' for description of Wait-To-Restore interval. nonrevertive : The protection line continues to be the active line, The active line does not switch to the working line." ::= { csApsConfigEntry 10 } csApsDirectionOperational OBJECT-TYPE SYNTAX INTEGER { uniDirectional(1), biDirectional(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This object shows the actual APS direction that is implemented on the Near End terminal. APS direction configured through csApsDirection is negotiated with the Far End and APS direction setting acceptable to both ends is operational at the Near End." ::= { csApsConfigEntry 11 } csApsArchModeOperational OBJECT-TYPE SYNTAX INTEGER { onePlusOne(1), oneToOne(2), anexBOnePlusOne(3), ycableOnePlusOneNok1k2(4), straightOnePlusOneNok1k2(5) } ACCESS read-only STATUS mandatory DESCRIPTION "This object shows the actual APS architecture mode that is implemented on the Near End terminal. APS architecture mode configured through csApsArchMode object is negotiated with the Far End through APS channel. Architecture mode acceptable to both the Near End and the Far End terminals is then operational at the Near End. This value can be different than the APS Architecture mode configured." ::= { csApsConfigEntry 12 } csApsChannelProtocol OBJECT-TYPE SYNTAX INTEGER { bellcore(1), itu(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This object allows to configure APS channel protocol to be implemented at Near End terminal. K1 and K2 overhead bytes in a SONET signal are used as an APS channel. This channel is used to carry APS protocol. Possible values: bellcore(1) : Implements APS channel protocol as defined in bellcore document GR-253-CORE. itu(2) : Implements APS channel protocol as defined in ITU document G.783." REFERENCE "GR-253-CORE, G.783" ::= { csApsConfigEntry 13 } csApsFailureStatus OBJECT-TYPE SYNTAX CsApsLineFailureStatus -- Rsyntax OCTET STRING(SIZE(1..2)) -- BITS are: -- noApsLineFailure(0) -- csApsChannelMismatchBit(1) -- csApsProtectionByteFailBit(2) -- csApsFEProtectionFailureBit(3) -- csApsModeMismatchBit(4) ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates APS line failure status." REFERENCE "GR-253-CORE, G.783" ::= { csApsConfigEntry 14 } csApsSwitchReason OBJECT-TYPE SYNTAX CsApsLineSwitchReason -- Rsyntax INTEGER { -- csApsOther(1), -- csApsRevertive(2), -- csApsManual(3), -- csApsSignalDefectLow(4), -- csApsSignalDefectHigh(5), -- csApsSignalFailureLow(6), -- csApsSignalFailureHigh(7), -- csApsForceSwitch(8), -- csApsLockOut(9), -- csApsNoSwitch(10) -- } ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates APS line switch reason." REFERENCE "GR-253-CORE, G.783" ::= { csApsConfigEntry 15 } csApsPrimarySection OBJECT-TYPE SYNTAX INTEGER { workingSection1(1), workingSection2(2), none(3) } ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates which working section is the APS primary section. In G.783 AnnexB, the K1/K2 Bytes are received on the secondary Section. All the Switch Requests are for a switch from the primary section to the secondary section. The object csApsActiveline will indicate which section is currently carrying the traffic. Once the switch request clears normally, traffic is maintained on the section to which it was switched by making that section the primary section. Possible values: workingSection1(1): Working Section 1 is Primary Section workingSection2(2): Working Section 2 is Primary Section none(3) : none." REFERENCE "G.783 AnnexB" ::= { csApsConfigEntry 16 } csApsLineFailureCode OBJECT-TYPE SYNTAX CsApsLineFailureCode -- Rsyntax INTEGER { -- csApsChannelMismatch(1), -- csApsProtectionByteFail(2), -- csApsFEProtectionFailure(3), -- csApsModeMismatch(4) -- } ACCESS read-only STATUS mandatory DESCRIPTION "The object indicates the APS line failure code. This is the failure encountered by the APS line. Refer to CsApsLineFailureCode TC for failure code definitions. The object is used for notifications." REFERENCE "GR-253-CORE, G.783" ::= { csApsConfig 2 } csApsLineSwitchReason OBJECT-TYPE SYNTAX CsApsLineSwitchReason -- Rsyntax INTEGER { -- csApsOther(1), -- csApsRevertive(2), -- csApsManual(3), -- csApsSignalDefectLow(4), -- csApsSignalDefectHigh(5), -- csApsSignalFailureLow(6), -- csApsSignalFailureHigh(7), -- csApsForceSwitch(8), -- csApsLockOut(9), -- csApsNoSwitch(10) -- } ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the APS line switch reason. When the working line on one end fails, its other end is told to do an APS switch. Refer to CsApsLineSwitchReason TC for more information. The object is used for notifications." ::= { csApsConfig 3 } cssTotalTable OBJECT-TYPE SYNTAX SEQUENCE OF CssTotalEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The SONET/SDH Section Total table. It contains the cumulative sum of the various statistics for the 24 hour period preceding the current interval. The object 'sonetMediumValidIntervals' from RFC2558 contains the number of 15 minute intervals that have elapsed since the line is enabled. " ::= { csSection 1 } cssTotalEntry OBJECT-TYPE SYNTAX CssTotalEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the SONET/SDH Section Total table. Entries are created automatically for sonet lines." INDEX { ifIndex } ::= { cssTotalTable 1 } CssTotalEntry ::= SEQUENCE { cssTotalESs Gauge, cssTotalSESs Gauge, cssTotalSEFSs Gauge, cssTotalCVs Gauge } cssTotalESs OBJECT-TYPE SYNTAX Gauge -- Units -- errored seconds ACCESS read-only STATUS mandatory DESCRIPTION "The number of Errored Seconds encountered by a SONET/SDH Section in the last 24 hours." REFERENCE " RFC2558 " ::= { cssTotalEntry 1 } cssTotalSESs OBJECT-TYPE SYNTAX Gauge -- Units -- severely errored seconds ACCESS read-only STATUS mandatory DESCRIPTION "The number of Severely Errored Seconds encountered by a SONET/SDH Section in the last 24 hours." REFERENCE " RFC2558 " ::= { cssTotalEntry 2 } cssTotalSEFSs OBJECT-TYPE SYNTAX Gauge -- Units -- severely errored framing seconds ACCESS read-only STATUS mandatory DESCRIPTION "The number of Severely Errored Framing Seconds encountered by a SONET/SDH Section in the last 24 hours." REFERENCE " RFC2558 " ::= { cssTotalEntry 3 } cssTotalCVs OBJECT-TYPE SYNTAX Gauge -- Units -- coding violations ACCESS read-only STATUS mandatory DESCRIPTION "The number of Coding Violations encountered by a SONET/SDH Section in the last 24 hours." REFERENCE " RFC2558 " ::= { cssTotalEntry 4 } cssTraceTable OBJECT-TYPE SYNTAX SEQUENCE OF CssTraceEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The SONET/SDH Section Trace table. This table contains objects for tracing the sonet section." ::= { csSection 2 } cssTraceEntry OBJECT-TYPE SYNTAX CssTraceEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the trace table. Entries exist for active sonet lines. The objects in this table are used to verify continued connection between the two ends of the line." INDEX { ifIndex } ::= { cssTraceTable 1 } CssTraceEntry ::= SEQUENCE { cssTraceToTransmit OCTET STRING, cssTraceToExpect OCTET STRING, cssTraceFailure TruthValue, cssTraceReceived OCTET STRING } cssTraceToTransmit OBJECT-TYPE SYNTAX OCTET STRING(SIZE(0|16|64)) ACCESS read-write STATUS mandatory DESCRIPTION "Sonet Section Trace To Transmit. This is string that is transmitted to perform Sonet section trace diagnostics. The trace string is repetitively transmited so that a trace receiving terminal can verify its continued connection to the intended transmitter. The default value is a zero-length string. Unless this object is set to a non-zero length string, tracing will not be performed." REFERENCE "GR-253-CORE" ::= { cssTraceEntry 1 } cssTraceToExpect OBJECT-TYPE SYNTAX OCTET STRING(SIZE(0|16|64)) ACCESS read-write STATUS mandatory DESCRIPTION "Sonet Section Trace To Expect. The receiving terminal verifies if the incoming string matches this string. The value of 'cssTraceFailure' indicates whether a trace mismatch occurred. The default value is a zero-length string." REFERENCE "GR-253-CORE" ::= { cssTraceEntry 2 } cssTraceFailure OBJECT-TYPE SYNTAX TruthValue -- Rsyntax INTEGER { -- true(1), -- false(2) -- } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object is set to 'true' when Sonet Section received trace does not match the 'cssTraceToExpect'." REFERENCE "GR-253-CORE" ::= { cssTraceEntry 3 } cssTraceReceived OBJECT-TYPE SYNTAX OCTET STRING(SIZE(0|16|64)) ACCESS read-only STATUS mandatory DESCRIPTION "This object is used to view the Sonet Section Trace that is received by the receiving terminal." REFERENCE "GR-253-CORE" ::= { cssTraceEntry 4 } cslTotalTable OBJECT-TYPE SYNTAX SEQUENCE OF CslTotalEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The SONET/SDH Line Total table. It contains the cumulative sum of the various statistics for the 24 hour period preceding the current interval. The object 'sonetMediumValidIntervals' from RFC2558 contains the number of 15 minute intervals that have elapsed since the line is enabled." ::= { csLine 1 } cslTotalEntry OBJECT-TYPE SYNTAX CslTotalEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the SONET/SDH Line Total table. Entries are created automatically for sonet lines." INDEX { ifIndex } ::= { cslTotalTable 1 } CslTotalEntry ::= SEQUENCE { cslTotalESs Gauge, cslTotalSESs Gauge, cslTotalCVs Gauge, cslTotalUASs Gauge } cslTotalESs OBJECT-TYPE SYNTAX Gauge -- Units -- errored seconds ACCESS read-only STATUS mandatory DESCRIPTION "The number of Errored Seconds encountered by a SONET/SDH Line in the last 24 hours." ::= { cslTotalEntry 1 } cslTotalSESs OBJECT-TYPE SYNTAX Gauge -- Units -- severely errored seconds ACCESS read-only STATUS mandatory DESCRIPTION "The number of Severely Errored Seconds encountered by a SONET/SDH Line in the last 24 hours." REFERENCE " RFC2558 " ::= { cslTotalEntry 2 } cslTotalCVs OBJECT-TYPE SYNTAX Gauge -- Units -- coding violations ACCESS read-only STATUS mandatory DESCRIPTION "The number of Coding Violations encountered by a SONET/SDH Line in the last 24 hours." REFERENCE " RFC2558 " ::= { cslTotalEntry 3 } cslTotalUASs OBJECT-TYPE SYNTAX Gauge -- Units -- unavailable seconds ACCESS read-only STATUS mandatory DESCRIPTION "The number of Unavailable Seconds encountered by a SONET/SDH Line in the last 24 hours." REFERENCE " RFC2558 " ::= { cslTotalEntry 4 } cslFarEndTotalTable OBJECT-TYPE SYNTAX SEQUENCE OF CslFarEndTotalEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The SONET/SDH Far End Line Total table. It contains the cumulative sum of the various statistics for the 24 hour period preceding the current interval. The object 'sonetMediumValidIntervals' from RFC2558 contains the number of 15 minute intervals that have elapsed since the line is enabled." ::= { csLine 2 } cslFarEndTotalEntry OBJECT-TYPE SYNTAX CslFarEndTotalEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the SONET/SDH Far End Line Total table. Entries are created automatically for sonet lines." INDEX { ifIndex } ::= { cslFarEndTotalTable 1 } CslFarEndTotalEntry ::= SEQUENCE { cslFarEndTotalESs Gauge, cslFarEndTotalSESs Gauge, cslFarEndTotalCVs Gauge, cslFarEndTotalUASs Gauge } cslFarEndTotalESs OBJECT-TYPE SYNTAX Gauge -- Units -- errored seconds ACCESS read-only STATUS mandatory DESCRIPTION "The number of Errored Seconds encountered by a SONET/SDH Far End Line in the last 24 hours." REFERENCE " RFC2558 " ::= { cslFarEndTotalEntry 1 } cslFarEndTotalSESs OBJECT-TYPE SYNTAX Gauge -- Units -- severely errored seconds ACCESS read-only STATUS mandatory DESCRIPTION "The number of Severely Errored Seconds encountered by a SONET/SDH Far End Line in the last 24 hours." REFERENCE " RFC2558 " ::= { cslFarEndTotalEntry 2 } cslFarEndTotalCVs OBJECT-TYPE SYNTAX Gauge -- Units -- coding violations ACCESS read-only STATUS mandatory DESCRIPTION "The number of Coding Violations encountered by a SONET/SDH Far End Line in the last 24 hours." REFERENCE " RFC2558 " ::= { cslFarEndTotalEntry 3 } cslFarEndTotalUASs OBJECT-TYPE SYNTAX Gauge -- Units -- unavailable seconds ACCESS read-only STATUS mandatory DESCRIPTION "The number of Unavailable Seconds encountered by a SONET/SDH Far End Line in the last 24 hours." REFERENCE " RFC2558 " ::= { cslFarEndTotalEntry 4 } cspTotalTable OBJECT-TYPE SYNTAX SEQUENCE OF CspTotalEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The SONET/SDH Path Total table. It contains the cumulative sum of the various statistics for the 24 hour period preceding the current interval.The object 'sonetMediumValidIntervals' from RFC2558 contains the number of 15 minute intervals that have elapsed since the line is enabled." ::= { csPath 1 } cspTotalEntry OBJECT-TYPE SYNTAX CspTotalEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the SONET/SDH Path Total table. Entries are created automatically for sonet lines." INDEX { ifIndex } ::= { cspTotalTable 1 } CspTotalEntry ::= SEQUENCE { cspTotalESs Gauge, cspTotalSESs Gauge, cspTotalCVs Gauge, cspTotalUASs Gauge } cspTotalESs OBJECT-TYPE SYNTAX Gauge -- Units -- errored seconds ACCESS read-only STATUS mandatory DESCRIPTION "The number of Errored Seconds encountered by a SONET/SDH Path in the last 24 hours." REFERENCE " RFC2558 " ::= { cspTotalEntry 1 } cspTotalSESs OBJECT-TYPE SYNTAX Gauge -- Units -- severely errored seconds ACCESS read-only STATUS mandatory DESCRIPTION "The number of Severely Errored Seconds encountered by a SONET/SDH Path in the last 24 hours." REFERENCE " RFC2558 " ::= { cspTotalEntry 2 } cspTotalCVs OBJECT-TYPE SYNTAX Gauge -- Units -- coding violations ACCESS read-only STATUS mandatory DESCRIPTION "The number of Coding Violations encountered by a SONET/SDH Path in the last 24 hours." REFERENCE " RFC2558 " ::= { cspTotalEntry 3 } cspTotalUASs OBJECT-TYPE SYNTAX Gauge -- Units -- unavailable seconds ACCESS read-only STATUS mandatory DESCRIPTION "The number of Unavailable Seconds encountered by a SONET/SDH Path in the last 24 hours." REFERENCE " RFC2558 " ::= { cspTotalEntry 4 } cspFarEndTotalTable OBJECT-TYPE SYNTAX SEQUENCE OF CspFarEndTotalEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The SONET/SDH Far End Path Total table. Far End is the remote end of the line. The table contains the cumulative sum of the various statistics for the 24 hour period preceding the current interval. The object 'sonetMediumValidIntervals' from RFC2558 contains the number of 15 minute intervals that have elapsed since the line is enabled. " ::= { csPath 2 } cspFarEndTotalEntry OBJECT-TYPE SYNTAX CspFarEndTotalEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the SONET/SDH Far End Path Total table. Entries are created automatically for sonet lines." INDEX { ifIndex } ::= { cspFarEndTotalTable 1 } CspFarEndTotalEntry ::= SEQUENCE { cspFarEndTotalESs Gauge, cspFarEndTotalSESs Gauge, cspFarEndTotalCVs Gauge, cspFarEndTotalUASs Gauge } cspFarEndTotalESs OBJECT-TYPE SYNTAX Gauge -- Units -- errored seconds ACCESS read-only STATUS mandatory DESCRIPTION "The number of Errored Seconds encountered by a SONET/SDH far end path in the last 24 hours." REFERENCE " RFC2558 " ::= { cspFarEndTotalEntry 1 } cspFarEndTotalSESs OBJECT-TYPE SYNTAX Gauge -- Units -- severely errored seconds ACCESS read-only STATUS mandatory DESCRIPTION "The number of Severely Errored Seconds encountered by a SONET/SDH far end path in the last 24 hours." REFERENCE " RFC2558 " ::= { cspFarEndTotalEntry 2 } cspFarEndTotalCVs OBJECT-TYPE SYNTAX Gauge -- Units -- coding violations ACCESS read-only STATUS mandatory DESCRIPTION "The number of Coding Violations encountered by a SONET/SDH far end path in the last 24 hours." REFERENCE " RFC2558 " ::= { cspFarEndTotalEntry 3 } cspFarEndTotalUASs OBJECT-TYPE SYNTAX Gauge -- Units -- unavailable seconds ACCESS read-only STATUS mandatory DESCRIPTION "The number of Unavailable Seconds encountered by a SONET/SDH far end path in the last 24 hours." REFERENCE " RFC2558 " ::= { cspFarEndTotalEntry 4 } cspTraceTable OBJECT-TYPE SYNTAX SEQUENCE OF CspTraceEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The SONET/SDH Path Trace table. This table contains objects for tracing the sonet path." ::= { csPath 3 } cspTraceEntry OBJECT-TYPE SYNTAX CspTraceEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the SONET/SDH Path Trace table. The entries exist for active sonet lines. The objects in this table are used to verify continued connection between the two ends of the line." INDEX { ifIndex } ::= { cspTraceTable 1 } CspTraceEntry ::= SEQUENCE { cspTraceToTransmit OCTET STRING, cspTraceToExpect OCTET STRING, cspTraceFailure TruthValue, cspTraceReceived OCTET STRING } cspTraceToTransmit OBJECT-TYPE SYNTAX OCTET STRING(SIZE(0|16|64)) ACCESS read-write STATUS mandatory DESCRIPTION "Sonet Path Trace To Transmit. The trace string is repetitively transmited so that a trace receiving terminal can verify its continued receiving terminal can verify its continued connection to the intended transmitter. The default value is a zero-length string. Unless this object is set to a non-zero length string, tracing will not be performed." REFERENCE "GR-253-CORE" ::= { cspTraceEntry 1 } cspTraceToExpect OBJECT-TYPE SYNTAX OCTET STRING(SIZE(0|16|64)) ACCESS read-write STATUS mandatory DESCRIPTION "Sonet Path Trace To Expect. The receiving terminal verifies if the incoming string matches this string. The value of 'cspTraceFailure' indicates whether a trace mismatch occured. The default value is a zero-length string." REFERENCE "GR-253-CORE" ::= { cspTraceEntry 2 } cspTraceFailure OBJECT-TYPE SYNTAX TruthValue -- Rsyntax INTEGER { -- true(1), -- false(2) -- } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object is set to 'true' when Sonet Path received trace does not match the 'cspTraceToExpect'." REFERENCE "GR-253-CORE" ::= { cspTraceEntry 3 } cspTraceReceived OBJECT-TYPE SYNTAX OCTET STRING(SIZE(0|16|64)) ACCESS read-only STATUS mandatory DESCRIPTION "This object is used to view the Sonet Path Trace that is received by the receiving terminal." REFERENCE "GR-253-CORE" ::= { cspTraceEntry 4 } csStatsTable OBJECT-TYPE SYNTAX SEQUENCE OF CsStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The SONET/SDH Section statistics table. This table maintains the number of times the line encountered Loss of Signal(LOS), Loss of frame(LOF), Alarm Indication signals(AISs), Remote failure indications(RFIs)." ::= { csStats 1 } csStatsEntry OBJECT-TYPE SYNTAX CsStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the SONET/SDH statistics table. These are realtime statistics for the Sonet section, line and path layers. The statistics are gathered for each sonet line. An entry is created automatically and is indexed by ifIndex." INDEX { ifIndex } ::= { csStatsTable 1 } CsStatsEntry ::= SEQUENCE { cssLOSs Counter, cssLOFs Counter, cslAISs Counter, cslRFIs Counter, cspAISs Counter, cspRFIs Counter } cssLOSs OBJECT-TYPE SYNTAX Counter -- Units -- loss of signals ACCESS read-only STATUS mandatory DESCRIPTION "The number of Loss of signals(LOS) encountered by a SONET/SDH Section. A high value for this object may indicate a problem with the Sonet Section layer." REFERENCE " RFC2558 " ::= { csStatsEntry 1 } cssLOFs OBJECT-TYPE SYNTAX Counter -- Units -- loss of frames ACCESS read-only STATUS mandatory DESCRIPTION "The number of Loss of Frames (LOF) encountered by a SONET/SDH Section. A high value for this object may indicate a problem with the Sonet Section layer." REFERENCE " RFC2558 " ::= { csStatsEntry 2 } cslAISs OBJECT-TYPE SYNTAX Counter -- Units -- alarm indication signals ACCESS read-only STATUS mandatory DESCRIPTION "The number of alarm indication signals(AIS) encountered by a SONET/SDH Line. A high value for this object may indicate a problem with the Sonet Line layer." REFERENCE " RFC2558 " ::= { csStatsEntry 3 } cslRFIs OBJECT-TYPE SYNTAX Counter -- Units -- remote failure indications ACCESS read-only STATUS mandatory DESCRIPTION "The number of remote failure indications (RFI) encountered by a SONET/SDH Line. A high value for this object may indicate a problem with the Sonet Line layer." REFERENCE " RFC2558 " ::= { csStatsEntry 4 } cspAISs OBJECT-TYPE SYNTAX Counter -- Units -- alarm indication signals ACCESS read-only STATUS mandatory DESCRIPTION "The number of alarm indication signals (AIS) encountered by a SONET/SDH Path. A high value for this object may indicate a problem with the Sonet Path layer." REFERENCE " RFC2558 " ::= { csStatsEntry 5 } cspRFIs OBJECT-TYPE SYNTAX Counter -- Units -- remote failure indications ACCESS read-only STATUS mandatory DESCRIPTION "The number of remote failure indications (RFI) encountered by a SONET/SDH Path. A high value for this object may indicate a problem with the Sonet Path layer." REFERENCE " RFC2558 " ::= { csStatsEntry 6 } cspConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF CspConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Cisco extension to SONET Path current table." ::= { cspConfig 1 } cspConfigEntry OBJECT-TYPE SYNTAX CspConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in Cisco extension to the SONET path current table." INDEX { ifIndex } -- Augments sonetPathCurrentEntry FROM SONET-MIB ::= { cspConfigTable 1 } CspConfigEntry ::= SEQUENCE { cspSonetPathPayload INTEGER, cspTributaryMappingType INTEGER, cspSignallingTransportMode INTEGER, cspTributaryGroupingType INTEGER } cspSonetPathPayload OBJECT-TYPE SYNTAX INTEGER { unequipped(1), unspecified(2), ds3(3), vt15vc11(4), vt2vc12(5), atmCell(6), hdlcFr(7), e3(8), vtStructured(9) } ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the payload carried by the SONET/SDH Path. The payload specification corresponds to C2 (Signal Label) overhead byte in SONET/SDH Path Overhead: unequipped(1) : Path is not provisioned to carry any payload. unspecified(2) : Path is carrying an unspecifed payload. ds3(3) : Path is carrying a DS3 path as payload. vt15vc11(4) : Path is carrying SONET-VT1.5/SDH-VC11 payload. vt2vc12(5) : Path is carrying SONET-VT2/SDH-VC12 as payload. atmCell(6) : Path is carrying ATM Cells as payload. hdlcFr(7) : Path is carrying Frame Relay (HDLC) payload. e3(8) : Path is carrying an E3 path as payload. vtStructured(9) : Path is carrying VTGs/TUG3s/TUG2s which may each carry a different payload. A write operation on this object will result in update to C2 overhead byte in the Path Overhead." REFERENCE "Telcordia GR-253, ITU G.707" ::= { cspConfigEntry 1 } cspTributaryMappingType OBJECT-TYPE SYNTAX INTEGER { asynchronous(1), byteSynchronous(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This object represents the VT/VC mapping type. asynchronous: In this mode, the channel structure of DS1/E1 is neither visible nor preserved. byteSynchronous: In this mode, the DS0 signals inside the VT/VC can be found and extracted from the frame. The initial value is asynchronous(1)." ::= { cspConfigEntry 2 } cspSignallingTransportMode OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), signallingTransferMode(2), clearMode(3) } ACCESS read-write STATUS mandatory DESCRIPTION "This object represents the mode used to transport DS0 Signalling information for T1 byteSynchronous mapping (GR253). In signallingTransferMode(2), the robbed-bit signalling is transferred to the VT header. In clearMode(3), only the framing bit is transferred to the VT header. The initial value is signallingTransferMode(2) if csTributaryMappingType is byteSynchronous. For asynchronous mapping, it is notApplicable(1). The value notApplicable(1) can not be set." ::= { cspConfigEntry 3 } cspTributaryGroupingType OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), au3Grouping(2), au4Grouping(3) } ACCESS read-write STATUS mandatory DESCRIPTION "This object represents the method used to group VCs into an STM-1 signal. Applicable only to SDH. au3Grouping: STM1<-AU-3<-TUG-2<-TU-12<-VC12 or STM1<-AU-3<-TUG-2<-TU-11<-VC11. au4Grouping: STM1<-AU-4<-TUG-3<-TUG-2<-TU-12<-VC12 or STM1<-AU-4<-TUG-3<-TUG-2<-TU-11<-VC11. The initial value is au3Grouping(2) for SDH and notApplicable(1) for SONET." REFERENCE "ITU-T,G707, Section 6 Basic Multiplexing Priciples" ::= { cspConfigEntry 4 } csAu4Tug3ConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF CsAu4Tug3ConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains objects to configure the VC( Virtual Container) related properties of a TUG-3 within a AU-4 paths. This table allows creation of following multiplexing structure: STM-1/AU-4/TUG-3/TU-3/DS3 STM-1/AU-4/TUG-3/TU-3/E3 STM-1/AU-4/TUG-3/TUG-2/TU-11/DS1 STM-1/AU-4/TUG-3/TUG-2/TU-12/E1 Three entries are created in this table for a given AU-4 path when cspSonetPathPayload object is set to one of the following: vt15vc11(4), vt2vc12(5), ds3(3), e3(8), vtStructured(9) " REFERENCE "ITU-T, G.707" ::= { csAu4Tug3Config 1 } csAu4Tug3ConfigEntry OBJECT-TYPE SYNTAX CsAu4Tug3ConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "There is an entry in this table for each TUG-3 within a AU-4 SDH path that supports SDH virtual container VC-4. The ifIndex value represents an entry in ifTable with ifType = sonetPath(50).The ifTable entry applicable for this entry belongs to AU-4 path." INDEX { ifIndex, csAu4Tug3 } ::= { csAu4Tug3ConfigTable 1 } CsAu4Tug3ConfigEntry ::= SEQUENCE { csAu4Tug3 INTEGER, csAu4Tug3Payload INTEGER } csAu4Tug3 OBJECT-TYPE SYNTAX INTEGER(1..3) ACCESS not-accessible STATUS mandatory DESCRIPTION "This object represents the TUG-3 number." REFERENCE "ITU-T G.707 for SDH Multiplexing hierarchy." ::= { csAu4Tug3ConfigEntry 1 } csAu4Tug3Payload OBJECT-TYPE SYNTAX INTEGER { other(1), vc11(2), vc12(3), tu3ds3(4), tu3e3(5) } ACCESS read-write STATUS mandatory DESCRIPTION "This object is used for configuring the payload for the tributary group. The possible values are : vc11 : When set to 'vc11' following things are done: - 28 entries created in ifTable for TU-11 with ifType = sonetVT(51) - 28 entries created in ifTable for DS1 with ifType = ds1(18) STM1<-AU-4<-TUG-3<-TUG-2<-TU-11<-VC11 vc12 : When set to 'vc12' following things are done: - 21 entries created in ifTable for TU-12 with ifType = sonetVT(51) - 21 entries created in ifTable for E1 with ifType = ds1(18) STM1<-AU-4<-TUG-3<-TUG-2<-TU-12<-VC12 tu3ds3 : When set to 'tu3ds3' following things are done: - 1 entry created in ifTable for TU-3 with ifType = sonetVT(51) - 1 entry created in ifTable for DS3 with ifType = ds3(30) STM1<-AU-4<-TUG-3<-TU-3<-VC3 tu3e3 : When set to 'tu3e3' following things are done: - 1 entry created in ifTable for TU-3 with ifType = sonetVT(51) - 1 entry created in ifTable for E3 with ifType = ds3(30) STM1<-AU-4<-TUG-3<-TU-3<-VC3 The value 'other' can not be set." DEFVAL { vc11 } ::= { csAu4Tug3ConfigEntry 2 } csNotificationsEnabled OBJECT-TYPE SYNTAX TruthValue -- Rsyntax INTEGER { -- true(1), -- false(2) -- } ACCESS read-write STATUS mandatory DESCRIPTION "This object controls if the generation of ciscoSonetSectionStatusChange, ciscoSonetLineStatusChange, ciscoSonetPathStatusChange and ciscoSonetVTStatusChange notifications is enabled. If the value of this object is 'true(1)', then all notifications in this MIB are enabled; otherwise they are disabled." DEFVAL { false } ::= { csNotifications 1 } ciscoSonetSectionStatusChange TRAP-TYPE -- Reverse mappable trap ENTERPRISE ciscoSonetMIB VARIABLES { sonetSectionCurrentStatus, ifDescr } -- Status -- mandatory DESCRIPTION "This notification is generated whenever the value of sonetSectionCurrentStatus changes." ::= 1 ciscoSonetLineStatusChange TRAP-TYPE -- Reverse mappable trap ENTERPRISE ciscoSonetMIB VARIABLES { sonetLineCurrentStatus, ifDescr } -- Status -- mandatory DESCRIPTION "This notification is generated whenever the value of sonetLineCurrentStatus changes." ::= 2 ciscoSonetPathStatusChange TRAP-TYPE -- Reverse mappable trap ENTERPRISE ciscoSonetMIB VARIABLES { sonetPathCurrentStatus, ifDescr } -- Status -- mandatory DESCRIPTION "This notification is generated whenever the value of sonetPathCurrentStatus changes." ::= 3 ciscoSonetVTStatusChange TRAP-TYPE -- Reverse mappable trap ENTERPRISE ciscoSonetMIB VARIABLES { sonetVTCurrentStatus, ifDescr } -- Status -- mandatory DESCRIPTION "This notification is generated whenever the value of sonetVTCurrentStatus changes." ::= 4 ciscoSonetConfMIBGroup OBJECT IDENTIFIER ::= { ciscoSonetMIBGroups 1 } -- OBJECT-GROUP -- Status -- deprecated -- Descr -- Objects used for configuring Sonet lines. -- objects -- csConfigLoopbackType, csConfigXmtClockSource, -- csConfigFrameScramble, csConfigType ciscoSonetStatsMIBGroup OBJECT IDENTIFIER ::= { ciscoSonetMIBGroups 2 } -- OBJECT-GROUP -- Status -- mandatory -- Descr -- These are objects related to Sonet line statistics. -- objects -- cssTotalESs, cssTotalSESs, cssTotalSEFSs, cssTotalCVs, -- cssLOSs, cssLOFs, cslAISs, cslRFIs, cspAISs, cspRFIs, -- cslTotalESs, cslTotalSESs, cslTotalCVs, cslTotalUASs, -- cslFarEndTotalESs, cslFarEndTotalSESs, cslFarEndTotalCVs, -- cslFarEndTotalUASs, cspTotalESs, cspTotalSESs, cspTotalCVs, -- cspTotalUASs, cspFarEndTotalESs, cspFarEndTotalSESs, -- cspFarEndTotalCVs, cspFarEndTotalUASs ciscoSonetTraceMIBGroup OBJECT IDENTIFIER ::= { ciscoSonetMIBGroups 3 } -- OBJECT-GROUP -- Status -- mandatory -- Descr -- Objects related to Sonet line connectivity. -- objects -- cssTraceToTransmit, cssTraceToExpect, cssTraceFailure, -- cssTraceReceived, cspTraceToTransmit, cspTraceToExpect, -- cspTraceFailure, cspTraceReceived ciscoSonetApsMIBGroup OBJECT IDENTIFIER ::= { ciscoSonetMIBGroups 4 } -- OBJECT-GROUP -- Status -- deprecated -- Descr -- Objects used for configuring APS over Sonet lines. -- objects -- csApsProtectionIndex, csApsEnable, csApsArchMode, -- csApsActiveLine, csApsSigFaultBER, csApsSigDegradeBER, -- csApsWaitToRestore, csApsDirection, csApsRevertive, -- csApsLineFailureCode, csApsLineSwitchReason, -- csApsDirectionOperational, csApsArchModeOperational, -- csApsChannelProtocol ciscoSonetApsMIBGroup1 OBJECT IDENTIFIER ::= { ciscoSonetMIBGroups 5 } -- OBJECT-GROUP -- Status -- mandatory -- Descr -- Objects used for configuring APS over Sonet lines. -- This group includes 3 new objects in addition to -- those in the deprecated group ciscoSonetApsMIBGroup. -- objects -- csApsProtectionIndex, csApsEnable, csApsArchMode, -- csApsActiveLine, csApsSigFaultBER, csApsSigDegradeBER, -- csApsWaitToRestore, csApsDirection, csApsRevertive, -- csApsLineFailureCode, csApsLineSwitchReason, -- csApsDirectionOperational, csApsArchModeOperational, -- csApsChannelProtocol, csApsFailureStatus, csApsSwitchReason, -- csApsPrimarySection ciscoSonetConfMIBGroup1 OBJECT IDENTIFIER ::= { ciscoSonetMIBGroups 6 } -- OBJECT-GROUP -- Status -- mandatory -- Descr -- Objects used for configuring Sonet lines. -- objects -- csConfigLoopbackType, csConfigXmtClockSource, -- csConfigFrameScramble, csConfigType, csConfigRDIPType, -- csConfigRDIVType ciscoSonetVTConfMIBGroup OBJECT IDENTIFIER ::= { ciscoSonetMIBGroups 7 } -- OBJECT-GROUP -- Status -- mandatory -- Descr -- Objects used for configuring Sonet Virtual tributaries. -- objects -- csTributaryType, csTributaryMappingType, -- csTributaryFramingType, csSignallingTransportMode, -- csTributaryGroupingType ciscoSonetPathConfMIBGroup OBJECT IDENTIFIER ::= { ciscoSonetMIBGroups 8 } -- OBJECT-GROUP -- Status -- mandatory -- Descr -- Objects used for configuring Sonet Paths. -- objects -- cspSonetPathPayload ciscoSonetNotifEnableGroup OBJECT IDENTIFIER ::= { ciscoSonetMIBGroups 9 } -- OBJECT-GROUP -- Status -- mandatory -- Descr -- The collection of objects which enable notifications. -- objects -- csNotificationsEnabled ciscoSonetPathConfMIBGroup1 OBJECT IDENTIFIER ::= { ciscoSonetMIBGroups 14 } -- OBJECT-GROUP -- Status -- mandatory -- Descr -- Objects used for configuring Sonet Paths. -- objects -- cspTributaryMappingType, cspSignallingTransportMode, -- cspTributaryGroupingType ciscoSonetAu4Tug3Group OBJECT IDENTIFIER ::= { ciscoSonetMIBGroups 15 } -- OBJECT-GROUP -- Status -- mandatory -- Descr -- Objects used for configuring AU-4:TUG-3 paths. -- objects -- csAu4Tug3Payload ciscoSonetSectionNotifGroup OBJECT IDENTIFIER ::= { ciscoSonetMIBGroups 10 } -- NOTIFICATION-GROUP -- Status -- mandatory -- Descr -- The collection of Section notifications which are -- required to be implemented. -- notifications -- ciscoSonetSectionStatusChange ciscoSonetLineNotifGroup OBJECT IDENTIFIER ::= { ciscoSonetMIBGroups 11 } -- NOTIFICATION-GROUP -- Status -- mandatory -- Descr -- The collection of Line notifications which are -- required to be implemented. -- notifications -- ciscoSonetLineStatusChange ciscoSonetPathNotifGroup OBJECT IDENTIFIER ::= { ciscoSonetMIBGroups 12 } -- NOTIFICATION-GROUP -- Status -- mandatory -- Descr -- The collection of Path notifications which are -- required to be implemented. -- notifications -- ciscoSonetPathStatusChange ciscoSonetVTNotifGroup OBJECT IDENTIFIER ::= { ciscoSonetMIBGroups 13 } -- NOTIFICATION-GROUP -- Status -- mandatory -- Descr -- The collection of VT notifications which are -- required to be implemented. -- notifications -- ciscoSonetVTStatusChange ciscoSonetMIBCompliance OBJECT IDENTIFIER ::= { ciscoSonetMIBCompliances 1 } -- MODULE-COMPLIANCE -- Status -- deprecated -- Descr -- The Compliance statement for ciscoSonet management group. -- Module -- >>current<< -- MandGroup -- ciscoSonetConfMIBGroup -- MandGroup -- ciscoSonetStatsMIBGroup -- MandGroup -- ciscoSonetTraceMIBGroup -- OptGroup -- ciscoSonetApsMIBGroup -- ObjVar -- cssTraceReceived -- ObjVar -- cspTraceReceived ciscoSonetMIBCompliance1 OBJECT IDENTIFIER ::= { ciscoSonetMIBCompliances 2 } -- MODULE-COMPLIANCE -- Status -- deprecated -- Descr -- The Compliance statement for ciscoSonet management group. -- Module -- >>current<< -- MandGroup -- ciscoSonetConfMIBGroup1 -- MandGroup -- ciscoSonetStatsMIBGroup -- MandGroup -- ciscoSonetTraceMIBGroup -- OptGroup -- ciscoSonetApsMIBGroup1 -- ObjVar -- cssTraceReceived -- ObjVar -- cspTraceReceived -- OptGroup -- ciscoSonetVTConfMIBGroup ciscoSonetMIBCompliance2 OBJECT IDENTIFIER ::= { ciscoSonetMIBCompliances 3 } -- MODULE-COMPLIANCE -- Status -- deprecated -- Descr -- The Compliance statement for ciscoSonet management group. -- Module -- >>current<< -- MandGroup -- ciscoSonetConfMIBGroup1 -- MandGroup -- ciscoSonetTraceMIBGroup -- MandGroup -- ciscoSonetNotifEnableGroup -- MandGroup -- ciscoSonetSectionNotifGroup -- ObjVar -- cssTraceReceived -- ObjVar -- cspTraceReceived -- OptGroup -- ciscoSonetVTConfMIBGroup -- OptGroup -- ciscoSonetPathConfMIBGroup -- OptGroup -- ciscoSonetPathConfMIBGroup1 -- OptGroup -- ciscoSonetStatsMIBGroup -- OptGroup -- ciscoSonetApsMIBGroup1 -- OptGroup -- ciscoSonetLineNotifGroup -- OptGroup -- ciscoSonetPathNotifGroup -- OptGroup -- ciscoSonetVTNotifGroup ciscoSonetMIBCompliance3 OBJECT IDENTIFIER ::= { ciscoSonetMIBCompliances 4 } -- MODULE-COMPLIANCE -- Status -- mandatory -- Descr -- The Compliance statement for ciscoSonet management group. -- Module -- >>current<< -- MandGroup -- ciscoSonetConfMIBGroup1 -- MandGroup -- ciscoSonetTraceMIBGroup -- MandGroup -- ciscoSonetNotifEnableGroup -- MandGroup -- ciscoSonetSectionNotifGroup -- ObjVar -- cssTraceReceived -- ObjVar -- cspTraceReceived -- OptGroup -- ciscoSonetVTConfMIBGroup -- OptGroup -- ciscoSonetPathConfMIBGroup -- OptGroup -- ciscoSonetPathConfMIBGroup1 -- OptGroup -- ciscoSonetStatsMIBGroup -- OptGroup -- ciscoSonetApsMIBGroup1 -- OptGroup -- ciscoSonetLineNotifGroup -- OptGroup -- ciscoSonetPathNotifGroup -- OptGroup -- ciscoSonetVTNotifGroup -- OptGroup -- ciscoSonetAu4Tug3Group END