-- MIB file created 25-Mar-2004 13:44:20, by -- SMICng version 2.2.11-beta(PRO)(Solaris), January 20, 2001. Enterprise key cisco.com CISCO-WAN-VISM-TONE-PLAN-MIB DEFINITIONS ::= BEGIN -- From file: "CISCO-WAN-VISM-TONE-PLAN-MIB.my" -- Compile options "4 7 F H N W 03 06 0B 0G 0N 0T" IMPORTS DisplayString, RowStatus FROM SNMPv2-TC-v1 ciscoWan FROM CISCOWAN-SMI OBJECT-TYPE FROM RFC-1212; vismTonePlanGrpMIB OBJECT IDENTIFIER ::= { ciscoWan 24 } -- MODULE-IDENTITY -- LastUpdated -- 200312170000Z -- OrgName -- Cisco Systems, Inc. -- ContactInfo -- Cisco Systems -- Customer Service -- -- Postal: 170 W Tasman Drive -- San Jose, CA 95134 -- USA -- -- Tel: +1 800 553-NETS -- -- E-mail: cs-voice@cisco.com -- Descr -- The MIB module is defined to configure the programmable -- Tone Plan feature on VISM. -- RevDate -- 200312170000Z -- RevDescr -- 1. Remove default value from vismEventCode object. -- 2. Change default value of vismFreqMaxDelay object -- from 3 to 10. -- 3. Change default value of vismMinOnCadence object -- from 3 to 20. -- 4. Change default value of vismMaxOffCadence object -- from 5 to 450. -- 5. Remove default value from vismFrequency1 object. -- 6. Remove default value from vismFrequency2 object. -- 7. Remove default value from vismFreqOnCadence object. -- 8. Change default value of seqToneMaximumGapDuration -- object from 10 to 15. -- 9. Change SYNTAX INTEGER to Integer32 except for -- enumerated integers in vismConfigToneDetectEntry. -- 10. Clarify description of object. -- RevDate -- 200304230000Z -- RevDescr -- -- Added Object vismConfigToneDetect (Programmable Tone) -- under vismTonePlan -- RevDate -- 200207190000Z -- RevDescr -- Give tonePlanIndex a range (1..1000) to be -- compiled in new SMICNG compiler (ver2.2.11-beta). -- RevDate -- 200112260000Z -- RevDescr -- Description changes for tonePlanEntryStatus, -- tonePlanProvisionFlag, vismTonePlanEntry. -- RevDate -- 200108050000Z -- RevDescr -- Results from MIB external interfaces review. -- RevDate -- 200104030000Z -- RevDescr -- Initial draft. Created new VISM Tone Plan Group. vismTonePlanGrpMIBObjects OBJECT IDENTIFIER ::= { vismTonePlanGrpMIB 1 } vismTonePlan OBJECT IDENTIFIER ::= { vismTonePlanGrpMIBObjects 1 } vismTonePlanControlGrp OBJECT IDENTIFIER ::= { vismTonePlan 1 } vismTonePlanTableGrp OBJECT IDENTIFIER ::= { vismTonePlan 2 } vismConfigToneDetectGrp OBJECT IDENTIFIER ::= { vismTonePlan 3 } vismSequentialToneDetectGrp OBJECT IDENTIFIER ::= { vismTonePlan 4 } vismToneNotificationPrefix OBJECT IDENTIFIER ::= { vismTonePlanGrpMIB 2 } vismToneNotifications OBJECT IDENTIFIER ::= { vismToneNotificationPrefix 0 } vismTonePlanMIBConformance OBJECT IDENTIFIER ::= { vismTonePlanGrpMIB 3 } vismTonePlanMIBCompliances OBJECT IDENTIFIER ::= { vismTonePlanMIBConformance 1 } vismTonePlanMIBGroups OBJECT IDENTIFIER ::= { vismTonePlanMIBConformance 2 } tonePlanCurrentSize OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the number of entries in vismTonePlanTable. " ::= { vismTonePlanControlGrp 1 } vismTonePlanTable OBJECT-TYPE SYNTAX SEQUENCE OF VismTonePlanEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains configuration information about different Tone Plans. The first 32 entries of the table are 'provisionable' followed by an implementation specific number of 'builtIn' entries. " ::= { vismTonePlanTableGrp 1 } vismTonePlanEntry OBJECT-TYPE SYNTAX VismTonePlanEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the vismTonePlanTable. Each entry consists of configuration information for a specific Tone Plan. The vismTonePlanTable is of fixed size with a predefined number of entries, where each entry contains usable information or not depending upon the value of the tonePlanEntryStatus MIB object. The configuration is retained after VISM card reboots. tonePlanRegionName, tonePlanVersionNumber, and tonePlanFileName can be modified only if the tonePlanProvisionFlag is 'provisionable' and tonePlanEntryStatus is 'configured' when loading a new tone plan (see MIB object tonePlanEntryStatus below). After the new tone plan is loaded, these three MIB objects may not be modified. To change these objects, the entry in this table must be deleted, and all objects re-added with new corrected values. The rest of the entries of this table, (the 'builtIn' ones) cannot be modified after the table is build at reload time. " INDEX { tonePlanIndex } ::= { vismTonePlanTable 1 } VismTonePlanEntry ::= SEQUENCE { tonePlanIndex INTEGER, tonePlanEntryStatus INTEGER, tonePlanProvisionFlag INTEGER, tonePlanRegionName DisplayString, tonePlanVersionNumber INTEGER, tonePlanFileName DisplayString } tonePlanIndex OBJECT-TYPE SYNTAX INTEGER(1..1000) ACCESS not-accessible STATUS mandatory DESCRIPTION " Serves as index to this table. However, the maximum entry allowed is specify in tonePlanCurrentSize. " ::= { vismTonePlanEntry 1 } tonePlanEntryStatus OBJECT-TYPE SYNTAX INTEGER { unused(1), configured(2), reloading(3), lostFile(4) } ACCESS read-write STATUS mandatory DESCRIPTION " This attribute specifies the status of this entry as to whether this entry (row) contains usable Tone Plan configuration information (object is set to 'configured'), or if it is empty (object is set to 'unused'), or if is temporarily (object is set to 'reloading') or permanently (object is set to 'lostFile') unusable. This tone plan information for this row can be used by a DS-1 line only if this object has a value of 'configured (2)'. To add a configured entry in the vismTonePlanTable table, there must be an existing empty row with its entry status set to 'unused(1)'. Then before this empty row in the vismTonePlanTable table can be changed to 'configured', it must, in one single operation, be given all the usable values necessary to be stored in the tonePlanRegionName, tonePlanVersionNumber and tonePlanFileName MIB objects for this row. In addition, those values for the tonePlanRegionName and tonePlanVersionNumber MIB objects pair must be unique with respect to every other row of the vismTonePlanTable. Then, as this existing empty row is set with all three valid entries for the tonePlanRegionName, tonePlanVersionNumber, and tonePlanFileName MIB objects, the Entry Status MIB object for this row will be finally, internally, set to 'configured(2)'. This final 'configured' status is the direct result of correctly setting these three MIB objects with valid data. In no case will an external manager be able to directly set this MIB object to 'configured(2)' by a SNMP set command, for such a single stand alone command will be rejected. Once a table entry is set to 'configured(2)' with valid tonePlanRegionName, tonePlanVersionNumber, and tonePlanFileName MIB objects for this row, then these MIB objects may not be modified by any subsequent SNMP set command. In the case where a row needs to have these objects changed, this entry must be cleared from the table (paragraph below) and a new entry added by the add process above. Once an entry exists in the vismTonePlanTable table it may be cleared and set to unused by setting this MIB object to 'unused(1)'. But before the entry status of any entry in this table can be set to 'unused(1)', there is a check to make sure there is no vismDsx1TonePlanRegion MIB object and vismDsx1TonePlanVersion MIB object pair in the dsx1VismCnfGrpTable MIB table that may point to or refer to this table entry (row) with its unique tonePlanRegionName and tonePlanVersionNumber. Once the entry status of an entry in this table is set to 'unused(1)', all the other MIB objects for this table row are set to defaults or to NULL. Once an entry is 'configured', if a subsequent card reset occurs the VISM card will attempt to restore all of the configuration information by doing the normal download of the latest MIB database, set all 'configured (2)' MIB objects to 'reloading (3)', and then do an automatic background process to retrieve all of the tone plan files from the server since they were not downloaded by the PXM. If this retrieval of the tone plan files succeeds then this MIB object will be set back to 'configured (2)'. If this file retrieval does not succeed, then this MIB object will be set to 'lostFile (4)'. In no way will an external manager be able to directly set this MIB object to 'reloading (3)' or 'lostFile (4)' by a SNMP set command. " DEFVAL { unused } ::= { vismTonePlanEntry 2 } tonePlanProvisionFlag OBJECT-TYPE SYNTAX INTEGER { builtIn(1), provisionable(2) } ACCESS read-only STATUS mandatory DESCRIPTION " This attribute specifies whether this entry contains predefined Tone Plan configuration information from internal firmware code (object is set to 'builtIn') or if it has been configured with tone plan configuration information that has been downloaded from the PXM (object is set to unused). Only entries that are provisionable may have their tonePlanEntryStatus MIB object marked as unused in this table. BuiltIn entries may not be marked as unused. " ::= { vismTonePlanEntry 3 } tonePlanRegionName OBJECT-TYPE SYNTAX DisplayString(SIZE(1..64)) -- Rsyntax OCTET STRING(SIZE(1..64)) ACCESS read-write STATUS mandatory DESCRIPTION " The region (or country) for which this tone plan is defined. Any other entry in this table may have an identical name, but the combination of tonePlanRegionName and tonePlanVersionNumber must be unique. This field may be from 1 to 64 alphabetic, numeric, or underscore characters long, with no embedded spaces. A NULL entry will consist of a single space character of length one. " ::= { vismTonePlanEntry 4 } tonePlanVersionNumber OBJECT-TYPE SYNTAX INTEGER(0..65535) ACCESS read-write STATUS mandatory DESCRIPTION " This attribute specifies this entry's version number for a tone plan for a region. Multiple tone plans may be defined for each region, but each of these tone plans must have a unique tonePlanRegionName and tonePlanVersionNumber. When a new tone plan is added for a region, it should be added with a newer(larger) version number. Allowed values are in range (1..65535) but a value of zero being set in this object means that this object is a NULL entry. " ::= { vismTonePlanEntry 5 } tonePlanFileName OBJECT-TYPE SYNTAX DisplayString(SIZE(1..32)) -- Rsyntax OCTET STRING(SIZE(1..32)) ACCESS read-write STATUS mandatory DESCRIPTION " This is the name of a valid file stored on the TFTP server which contains the tone definitions. A missing or invalid file name will cause a failure in the configuration of this entry. If this entry points to a build-in tone plan predefined in firmware, then this name will be: 'BUILTIN'. Provisionable file names are not allowed to have the string 'BUILTIN' as their names. This field may be from 1 to 32 alphabetic, numeric, or underscore characters (no embedded spaces) long for a valid entry. A NULL entry will consist of a single space character of length one. " ::= { vismTonePlanEntry 6 } vismConfigToneDetectTable OBJECT-TYPE SYNTAX SEQUENCE OF VismConfigToneDetectEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains the list of user configurable dual frequency tones that can be detected on VISM. The call agent can request the VISM to detect any of the tones defined in this table. Entries to this table can only be added or deleted, not modified. Individual parameters within a row cannot be changed without deleting and re-adding the entry. " ::= { vismConfigToneDetectGrp 1 } vismConfigToneDetectEntry OBJECT-TYPE SYNTAX VismConfigToneDetectEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This is the primary entry in the vismConfigToneDetectTable. Each entry references a User configurable dual frequency tones that can be detected on VISM. " INDEX { vismConfigToneDetectNum } ::= { vismConfigToneDetectTable 1 } VismConfigToneDetectEntry ::= SEQUENCE { vismConfigToneDetectNum INTEGER, vismEventCode INTEGER, vismConfigToneDetectRowStatus RowStatus, vismFreqMaxDeviation INTEGER, vismFreqMaxPower INTEGER, vismFreqMinPower INTEGER, vismFreqPowerTwist INTEGER, vismFreqMaxDelay INTEGER, vismMinOnCadence INTEGER, vismMaxOffCadence INTEGER, vismFreqNumOfCadenceMatch INTEGER, vismFrequency1 INTEGER, vismFrequency2 INTEGER, vismFreqOnCadence INTEGER, vismFreqOffCadence INTEGER } vismConfigToneDetectNum OBJECT-TYPE SYNTAX INTEGER(1..10) ACCESS read-only STATUS mandatory DESCRIPTION "This is the index of this table. Currently only tones 1 to 10 are used and call agent can request up to ten tones to be detected on different endpoints at any point in time. " ::= { vismConfigToneDetectEntry 1 } vismEventCode OBJECT-TYPE SYNTAX INTEGER(0..255) ACCESS read-write STATUS mandatory DESCRIPTION "This is the secondary index of this table. Call agent can request supervision tone detection indexed by this field. The values of event code are mapped from the subscriber line event codes defined in RFC2833. Currently VISM supports detection of only a handful of supervision tones like Ringing, Busy, Dial-Tone and SIT tones. " ::= { vismConfigToneDetectEntry 2 } vismConfigToneDetectRowStatus OBJECT-TYPE SYNTAX RowStatus -- Rsyntax INTEGER { -- active(1), -- notInService(2), -- notReady(3), -- createAndGo(4), -- createAndWait(5), -- destroy(6) -- } ACCESS read-write STATUS mandatory DESCRIPTION "Controls the creation and deletion of a Config Tone. An entry may be created using the 'createAndGo' option. When the row is successfully created, the vismConfigToneDetectRowStatus would be set to 'active' by the agent. An entry may be deleted by setting the vismConfigToneDetectRowStatus to 'destroy'. " ::= { vismConfigToneDetectEntry 3 } vismFreqMaxDeviation OBJECT-TYPE SYNTAX INTEGER(10..125) -- Units -- Hz ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the maximum frequency deviation to be used by VISM when detecting a specific dual frequency tone. Please refer the VISM configuration guide for standard values to be used for this field. " DEFVAL { 30 } ::= { vismConfigToneDetectEntry 4 } vismFreqMaxPower OBJECT-TYPE SYNTAX INTEGER(0..30) -- Units -- dB ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the maximum frequency power to be used by VISM when detecting a specific dual frequency tone. Please refer the VISM configuration guide for standard values to be used for this field. " DEFVAL { 0 } ::= { vismConfigToneDetectEntry 5 } vismFreqMinPower OBJECT-TYPE SYNTAX INTEGER(10..35) -- Units -- dB ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the minimum frequency power to be used by VISM when detecting a specific dual frequency tone. Please refer the VISM configuration guide for standard values to be used for this field. " DEFVAL { 35 } ::= { vismConfigToneDetectEntry 6 } vismFreqPowerTwist OBJECT-TYPE SYNTAX INTEGER(0..15) -- Units -- dB ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the maximum frequency power twist permitted between the two frequencies used by VISM when detecting a dual frequency tone. Please refer the VISM configuration guide for standard values to be used for this field. " DEFVAL { 10 } ::= { vismConfigToneDetectEntry 7 } vismFreqMaxDelay OBJECT-TYPE SYNTAX INTEGER(0..100) -- Units -- milliseconds ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the maximum frequency delay to be used by VISM when detecting a dual frequency tone. Please refer the VISM configuration guide for standard values to be used for this field. It is measured in units of 10ms. " DEFVAL { 10 } ::= { vismConfigToneDetectEntry 8 } vismMinOnCadence OBJECT-TYPE SYNTAX INTEGER(3..100) -- Units -- milliseconds ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the minimum tone cycle ON time that is necessary for the VISM to detect the dual frequency tone. The vismMinOnCadence has to be less than vismFreqOnCadence value. Please refer the VISM configuration guide for standard values to be used for this field. " DEFVAL { 20 } ::= { vismConfigToneDetectEntry 9 } vismMaxOffCadence OBJECT-TYPE SYNTAX INTEGER(5..5000) ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the maximum tone cycle OFF time that is necessary for the VISM to detect the dual frequency tone. The vismMaxOffCadence should be greater than vismFreqOffCadence value. Please refer the VISM configuration guide for standard values to be used for this field. " DEFVAL { 450 } ::= { vismConfigToneDetectEntry 10 } vismFreqNumOfCadenceMatch OBJECT-TYPE SYNTAX INTEGER(0..6) ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the number of pairs of the dual frequency that needs to be detected. Currently ten pairs of frequency can be detected by the DSP. " DEFVAL { 1 } ::= { vismConfigToneDetectEntry 11 } vismFrequency1 OBJECT-TYPE SYNTAX INTEGER(280..3800) -- Units -- Hz ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the 1st frequency component of the dual frequency to be detected by the VISM. " ::= { vismConfigToneDetectEntry 12 } vismFrequency2 OBJECT-TYPE SYNTAX INTEGER(0..3800) -- Units -- Hz ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the 2nd frequency component of the dual frequency to be detected by the DSP. A value of 0 means this is a single frequency. The range of 1 to 279 is not a valid range in the DSP. " ::= { vismConfigToneDetectEntry 13 } vismFreqOnCadence OBJECT-TYPE SYNTAX INTEGER(3..5000) -- Units -- milliseconds ACCESS read-write STATUS mandatory DESCRIPTION "The On time in each cycle of the dual frequency to be detected by the DSP. The vismFreqOnCadence has to be less than vismMinOnCadence value. It is measured in units of 10ms. " ::= { vismConfigToneDetectEntry 14 } vismFreqOffCadence OBJECT-TYPE SYNTAX INTEGER(5..5000) -- Units -- milliseconds ACCESS read-write STATUS mandatory DESCRIPTION "The Off time in each cycle of the dual frequency to be detected by the DSP. The vismFreqOffCadence should be lesser than the vismMaxOffCadence value. It is measured in units of 10ms. " ::= { vismConfigToneDetectEntry 15 } seqToneNumOfFrequencies OBJECT-TYPE SYNTAX INTEGER(1..10) ACCESS read-write STATUS mandatory DESCRIPTION " The number of single frequencies which have to be detected by the sequential tone detector command on VISM. The frequencies should specified below (seqToneFrequency1 to seqToneFrequency10). This number should correspond to the non-zero frequency values seqToneFrequency1 to seqToneFrequency10. " DEFVAL { 3 } ::= { vismSequentialToneDetectGrp 1 } seqToneEventID OBJECT-TYPE SYNTAX INTEGER(0..255) ACCESS read-write STATUS mandatory DESCRIPTION " The eventID corresponding to the sequential frequency. Currently only supports Event 74 (SIT tone) " DEFVAL { 74 } ::= { vismSequentialToneDetectGrp 2 } seqToneDurationOfEachTone OBJECT-TYPE SYNTAX INTEGER(1..65534) ACCESS read-write STATUS mandatory DESCRIPTION " Nominal tone duration of each single tone in counts of 10ms used with sequential tone detector on VISM DSP. " DEFVAL { 33 } ::= { vismSequentialToneDetectGrp 3 } seqToneGapBetweenEachTone OBJECT-TYPE SYNTAX INTEGER(1..65534) ACCESS read-write STATUS mandatory DESCRIPTION " Nominal silence gap duration between each tone in 10ms used with sequential tone detector on VISM DSP. " DEFVAL { 1 } ::= { vismSequentialToneDetectGrp 4 } seqToneDurationDeviation OBJECT-TYPE SYNTAX INTEGER(1..4095) ACCESS read-write STATUS mandatory DESCRIPTION " Tone duration deviation allowed in 10ms used with sequential tone detector on VISM DSP. " DEFVAL { 2 } ::= { vismSequentialToneDetectGrp 5 } seqToneMaximumGapDuration OBJECT-TYPE SYNTAX INTEGER(1..4095) ACCESS read-write STATUS mandatory DESCRIPTION " Maximum tone duration allowed in 10ms used with sequential tone detector on VISM DSP. " DEFVAL { 15 } ::= { vismSequentialToneDetectGrp 6 } seqToneGapDurationDeviation OBJECT-TYPE SYNTAX INTEGER(1..4095) ACCESS read-write STATUS mandatory DESCRIPTION " Tone duration deviation allowed in 10ms used with sequential tone detector on VISM DSP. " DEFVAL { 20 } ::= { vismSequentialToneDetectGrp 7 } seqToneFreqDeviation OBJECT-TYPE SYNTAX INTEGER(1..1000) ACCESS read-write STATUS mandatory DESCRIPTION " Frequency deviation allowed (1 - 1000 Hz) used with sequential tone detector on VISM DSP. " DEFVAL { 40 } ::= { vismSequentialToneDetectGrp 8 } seqTonePowerLevelCeiling OBJECT-TYPE SYNTAX INTEGER(0..40) ACCESS read-write STATUS mandatory DESCRIPTION " Maximum ceiling power level of the sequential frequency tone (absolute value in dBm) used with sequential tone detector on VISM DSP. Range from 0 to 40 (0 to -40dB) " DEFVAL { 3 } ::= { vismSequentialToneDetectGrp 9 } seqTonePowerLevelFloor OBJECT-TYPE SYNTAX INTEGER(0..40) ACCESS read-write STATUS mandatory DESCRIPTION " Lowest (floor) power level of the sequential frequency tone (absolute value in dBm) used with sequential tone detector on VISM DSP. Range from 0 to 40 (0 to -40dB) " DEFVAL { 40 } ::= { vismSequentialToneDetectGrp 10 } seqToneFrequency1 OBJECT-TYPE SYNTAX INTEGER(280..3800) ACCESS read-write STATUS mandatory DESCRIPTION " 1st frequency in the SequentialTone to detect (280 - 3800), used with sequential tone detector on VISM DSP. " DEFVAL { 950 } ::= { vismSequentialToneDetectGrp 11 } seqToneFrequency2 OBJECT-TYPE SYNTAX INTEGER(280..3800) ACCESS read-write STATUS mandatory DESCRIPTION " 2nd frequency in the SequentialTone to detect (280 - 3800), used with sequential tone detector on VISM DSP. " DEFVAL { 1400 } ::= { vismSequentialToneDetectGrp 12 } seqToneFrequency3 OBJECT-TYPE SYNTAX INTEGER(280..3800) ACCESS read-write STATUS mandatory DESCRIPTION " 3rd frequency in the SequentialTone to detect (280 - 3800), used with sequential tone detector on VISM DSP. " DEFVAL { 1800 } ::= { vismSequentialToneDetectGrp 13 } seqToneFrequency4 OBJECT-TYPE SYNTAX INTEGER(280..3800) ACCESS read-write STATUS mandatory DESCRIPTION " 4th frequency in the SequentialTone to detect (280 - 3800), used with sequential tone detector on VISM DSP. " DEFVAL { 280 } ::= { vismSequentialToneDetectGrp 14 } seqToneFrequency5 OBJECT-TYPE SYNTAX INTEGER(280..3800) ACCESS read-write STATUS mandatory DESCRIPTION " 5th frequency in the SequentialTone to detect (280 - 3800), used with sequential tone detector on VISM DSP. " DEFVAL { 280 } ::= { vismSequentialToneDetectGrp 15 } seqToneFrequency6 OBJECT-TYPE SYNTAX INTEGER(280..3800) ACCESS read-write STATUS mandatory DESCRIPTION " 6th frequency in the SequentialTone to detect (280 - 3800), used with sequential tone detector on VISM DSP. " DEFVAL { 280 } ::= { vismSequentialToneDetectGrp 16 } seqToneFrequency7 OBJECT-TYPE SYNTAX INTEGER(280..3800) ACCESS read-write STATUS mandatory DESCRIPTION " 7th frequency in the SequentialTone to detect (280 - 3800), used with sequential tone detector on VISM DSP. " DEFVAL { 280 } ::= { vismSequentialToneDetectGrp 17 } seqToneFrequency8 OBJECT-TYPE SYNTAX INTEGER(280..3800) ACCESS read-write STATUS mandatory DESCRIPTION " 8th frequency in the SequentialTone to detect (280 - 3800), used with sequential tone detector on VISM DSP. " DEFVAL { 280 } ::= { vismSequentialToneDetectGrp 18 } seqToneFrequency9 OBJECT-TYPE SYNTAX INTEGER(280..3800) ACCESS read-write STATUS mandatory DESCRIPTION " 9th frequency in the SequentialTone to detect (280 - 3800), used with sequential tone detector on VISM DSP. " DEFVAL { 280 } ::= { vismSequentialToneDetectGrp 19 } seqToneFrequency10 OBJECT-TYPE SYNTAX INTEGER(280..3800) ACCESS read-write STATUS mandatory DESCRIPTION " 10th frequency in the SequentialTone to detect (280 - 3800), used with sequential tone detector on VISM DSP. " DEFVAL { 280 } ::= { vismSequentialToneDetectGrp 20 } vismTonePlanControlGroup OBJECT IDENTIFIER ::= { vismTonePlanMIBGroups 1 } -- OBJECT-GROUP -- Status -- mandatory -- Descr -- This group contains objects related to control of -- VISM Tone Plan Table. -- -- objects -- tonePlanCurrentSize vismTonePlanTableGroup OBJECT IDENTIFIER ::= { vismTonePlanMIBGroups 2 } -- OBJECT-GROUP -- Status -- mandatory -- Descr -- This group contains objects related to configuration -- of VISM Tone Plan. -- -- objects -- tonePlanEntryStatus, tonePlanProvisionFlag, -- tonePlanRegionName, tonePlanVersionNumber, tonePlanFileName vismConfigToneDetectTableGroup OBJECT IDENTIFIER ::= { vismTonePlanMIBGroups 3 } -- OBJECT-GROUP -- Status -- mandatory -- Descr -- This group contains objects related to configuration -- of VISM dual frequency detect tones. -- -- objects -- vismConfigToneDetectNum, vismEventCode, -- vismConfigToneDetectRowStatus, vismFreqMaxDeviation, -- vismFreqMaxPower, vismFreqMinPower, vismFreqPowerTwist, -- vismFreqMaxDelay, vismMinOnCadence, vismMaxOffCadence, -- vismFreqNumOfCadenceMatch, vismFrequency1, vismFrequency2, -- vismFreqOnCadence, vismFreqOffCadence vismSequentialToneDetectGroup OBJECT IDENTIFIER ::= { vismTonePlanMIBGroups 4 } -- OBJECT-GROUP -- Status -- mandatory -- Descr -- This group contains objects related to configuration -- of VISM sequential single frequency tone detection. -- -- objects -- seqToneNumOfFrequencies, seqToneEventID, -- seqToneDurationOfEachTone, seqToneGapBetweenEachTone, -- seqToneDurationDeviation, seqToneMaximumGapDuration, -- seqToneGapDurationDeviation, seqToneFreqDeviation, -- seqTonePowerLevelCeiling, seqTonePowerLevelFloor, -- seqToneFrequency1, seqToneFrequency2, seqToneFrequency3, -- seqToneFrequency4, seqToneFrequency5, seqToneFrequency6, -- seqToneFrequency7, seqToneFrequency8, seqToneFrequency9, -- seqToneFrequency10 vismTonePlanMIBCompliance OBJECT IDENTIFIER ::= { vismTonePlanMIBCompliances 1 } -- MODULE-COMPLIANCE -- Status -- mandatory -- Descr -- The complaince statement for VISM Tone Plan group -- which implements vismTonePlanGrp MIB. -- Module -- >>current<< -- MandGroup -- vismTonePlanControlGroup -- MandGroup -- vismTonePlanTableGroup -- MandGroup -- vismConfigToneDetectTableGroup -- MandGroup -- vismSequentialToneDetectGroup -- ObjVar -- vismConfigToneDetectRowStatus END