-- MIB file created 18-Feb-2003 15:44:35, by -- SMICng version 2.2.11-beta(PRO)(Solaris), January 20, 2001. Enterprise key cisco.com IEEE802dot11-MIB DEFINITIONS ::= BEGIN -- From file: "IEEE802dot11-MIB.my" -- Compile options "4 7 F H N W 03 06 0B 0G 0N 0T" IMPORTS DisplayString, MacAddress, RowStatus, TruthValue FROM SNMPv2-TC-v1 ifIndex FROM RFC1213-MIB Counter, Gauge FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212 TRAP-TYPE FROM RFC-1215; ieee802dot11 OBJECT IDENTIFIER ::= { us 10036 } -- MODULE-IDENTITY -- LastUpdated -- 0208300000Z -- OrgName -- IEEE 802.11 -- ContactInfo -- WG E-mail: stds-802-11@ieee.org -- -- Chair: Stuart J. Kerry -- Postal: Philips Semiconductors, Inc. -- 1109 McKay Drive -- M/S 48 SJ -- San Jose, CA 95130-1706 USA -- Tel: +1 408 474 7356 -- Fax: +1 408 474 7247 -- E-mail: stuart.kerry@philips.com -- -- Editor: Bob O'Hara -- Postal: Informed Technology, Inc. -- 1750 Nantucket Circle, Suite 138 -- Santa Clara, CA 95054 USA -- Tel: +1 408 986 9596 -- Fax: +1 408 727 2654 -- E-mail: bob@informed-technology.com -- Descr -- The MIB module for IEEE 802.11 entities. -- iso(1).member-body(2).us(840).ieee802dot11(10036) member-body OBJECT IDENTIFIER ::= { iso 2 } us OBJECT IDENTIFIER ::= { member-body 840 } dot11smt OBJECT IDENTIFIER ::= { ieee802dot11 1 } dot11mac OBJECT IDENTIFIER ::= { ieee802dot11 2 } dot11res OBJECT IDENTIFIER ::= { ieee802dot11 3 } dot11resAttribute OBJECT IDENTIFIER ::= { dot11res 1 } dot11phy OBJECT IDENTIFIER ::= { ieee802dot11 4 } dot11SMTnotification OBJECT IDENTIFIER ::= { dot11smt 6 } dot11Conformance OBJECT IDENTIFIER ::= { ieee802dot11 5 } dot11Groups OBJECT IDENTIFIER ::= { dot11Conformance 1 } dot11Compliances OBJECT IDENTIFIER ::= { dot11Conformance 2 } WEPKeytype ::= OCTET STRING(SIZE(5)) dot11StationConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11StationConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Station Configuration attributes. In tablular form to allow for multiple instances on an agent." ::= { dot11smt 1 } dot11StationConfigEntry OBJECT-TYPE SYNTAX Dot11StationConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the dot11StationConfigTable. It is possible for there to be multiple IEEE 802.11 interfaces on one agent, each with its unique MAC address. The relationship between an IEEE 802.11 interface and an interface in the context of the Internet-standard MIB is one-to-one. As such, the value of an ifIndex object instance can be directly used to identify corresponding instances of the objects defined herein. ifIndex - Each IEEE 802.11 interface is represented by an ifEntry. Interface tables in this MIB module are indexed by ifIndex." INDEX { ifIndex } ::= { dot11StationConfigTable 1 } Dot11StationConfigEntry ::= SEQUENCE { dot11StationID MacAddress, dot11MediumOccupancyLimit INTEGER, dot11CFPollable TruthValue, dot11CFPPeriod INTEGER, dot11CFPMaxDuration INTEGER, dot11AuthenticationResponseTimeOut Gauge, dot11PrivacyOptionImplemented TruthValue, dot11PowerManagementMode INTEGER, dot11DesiredSSID OCTET STRING, dot11DesiredBSSType INTEGER, dot11OperationalRateSet OCTET STRING, dot11BeaconPeriod INTEGER, dot11DTIMPeriod INTEGER, dot11AssociationResponseTimeOut Gauge, dot11DisassociateReason INTEGER, dot11DisassociateStation MacAddress, dot11DeauthenticateReason INTEGER, dot11DeauthenticateStation MacAddress, dot11AuthenticateFailStatus INTEGER, dot11AuthenticateFailStation MacAddress, dot11MultiDomainCapabilityImplemented TruthValue, dot11MultiDomainCapabilityEnabled TruthValue, dot11CountryString OCTET STRING } dot11StationID OBJECT-TYPE SYNTAX MacAddress -- Rsyntax OCTET STRING(SIZE(6)) ACCESS read-write STATUS deprecated DESCRIPTION "The purpose of dot11StationID is to allow a manager to identify a station for its own purposes. This attribute provides for that eventuality while keeping the true MAC address independent. Its syntax is MAC address, and the default value is the station's assigned, unique MAC address." ::= { dot11StationConfigEntry 1 } dot11MediumOccupancyLimit OBJECT-TYPE SYNTAX INTEGER(0..1000) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute shall indicate the maximum amount of time, in TU, that a point coordinator (PC) may control the usage of the wireless medium (WM) without relinquishing control for long enough to allow at least one instance of DCF access to the medium. The default value of this attribute shall be 100, and the maximum value shall be 1000." ::= { dot11StationConfigEntry 2 } dot11CFPollable OBJECT-TYPE SYNTAX TruthValue -- Rsyntax INTEGER { -- true(1), -- false(2) -- } ACCESS read-only STATUS mandatory DESCRIPTION "When this attribute is true, it shall indicate that the STA is able to respond to a CF-Poll with a data frame within a SIFS time. This attribute shall be false if the STA is not able to respond to a CF-Poll with a data frame within a SIFS time." ::= { dot11StationConfigEntry 3 } dot11CFPPeriod OBJECT-TYPE SYNTAX INTEGER(0..255) ACCESS read-write STATUS mandatory DESCRIPTION "The attribute shall describe the number of DTIM intervals between the start of CFPs. It is modified by MLME-START.request primitive." ::= { dot11StationConfigEntry 4 } dot11CFPMaxDuration OBJECT-TYPE SYNTAX INTEGER(0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "The attribute shall describe the maximum duration of the CFP in TU that may be generated by the PCF. It is modified by MLME-START.request primitive." ::= { dot11StationConfigEntry 5 } dot11AuthenticationResponseTimeOut OBJECT-TYPE SYNTAX Gauge(1..4294967295) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute shall specify the number of time units (TUs) that a responding STA should wait for the next frame in the authentication sequence." ::= { dot11StationConfigEntry 6 } dot11PrivacyOptionImplemented OBJECT-TYPE SYNTAX TruthValue -- Rsyntax INTEGER { -- true(1), -- false(2) -- } ACCESS read-only STATUS mandatory DESCRIPTION "This attribute, when true, shall indicate that the IEEE 802.11 WEP option is implemented. The default value of this attribute shall be false." ::= { dot11StationConfigEntry 7 } dot11PowerManagementMode OBJECT-TYPE SYNTAX INTEGER { active(1), powersave(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This attribute shall specify the power management mode of the STA. When set to active, it shall indicate that the station is not in power-save (PS) mode. When set to powersave, it shall indicate that the station is in power-save mode. The power management mode is transmitted in all frames according to the rules in 7.1.3.1.7." ::= { dot11StationConfigEntry 8 } dot11DesiredSSID OBJECT-TYPE SYNTAX OCTET STRING(SIZE(0..32)) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute reflects the Service Set ID (SSID) used in the DesiredSSID parameter of the most recent MLME_Scan.request. This value may be modified by an external management entity and used by the local SME to make decisions about the Scanning process." ::= { dot11StationConfigEntry 9 } dot11DesiredBSSType OBJECT-TYPE SYNTAX INTEGER { infrastructure(1), independent(2), any(3) } ACCESS read-write STATUS mandatory DESCRIPTION "This attribute shall specify the type of BSS the station shall use when scanning for a BSS with which to synchronize. This value is used to filter Probe Response frames and Beacons. When set to infrastructure, the station shall only synchronize with a BSS whose Capability Information field has the ESS subfield set to 1. When set to independent, the station shall only synchronize with a BSS whose Capability Information field has the IBSS subfield set to 1. When set to any, the station may synchronize to either type of BSS." ::= { dot11StationConfigEntry 10 } dot11OperationalRateSet OBJECT-TYPE SYNTAX OCTET STRING(SIZE(1..126)) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute shall specify the set of data rates at which the station may transmit data. Each octet contains a value representing a rate. Each rate shall be within the range from 2 to 127, corresponding to data rates in increments of 500 kbit/s from 1 Mbit/s to 63.5 Mbit/s, and shall be supported (as indicated in the supported rates table) for receiving data. This value is reported in transmitted Beacon, Probe Request, Probe Response, Association Request, Association Response, Reassociation Request, and Reassociation Response frames, and is used to determine whether a BSS with which the station desires to synchronize is suitable. It is also used when starting a BSS, as specified in 10.3." ::= { dot11StationConfigEntry 11 } dot11BeaconPeriod OBJECT-TYPE SYNTAX INTEGER(1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute shall specify the number of TUs that a station shall use for scheduling Beacon transmissions. This value is transmitted in Beacon and Probe Response frames." ::= { dot11StationConfigEntry 12 } dot11DTIMPeriod OBJECT-TYPE SYNTAX INTEGER(1..255) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute shall specify the number of beacon intervals that shall elapse between transmission of Beacons frames containing a TIM element whose DTIM Count field is 0. This value is transmitted in the DTIM Period field of Beacon frames." ::= { dot11StationConfigEntry 13 } dot11AssociationResponseTimeOut OBJECT-TYPE SYNTAX Gauge(1..4294967295) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute shall specify the number of TU that a requesting STA should wait for a response to a transmitted association-request MMPDU." ::= { dot11StationConfigEntry 14 } dot11DisassociateReason OBJECT-TYPE SYNTAX INTEGER(0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute holds the most recently transmitted Reason Code in a Disassociation frame. If no Disassociation frame has been transmitted, the value of this attribute shall be 0." REFERENCE "IEEE Std 802.11-2002, 7.3.1.7" ::= { dot11StationConfigEntry 15 } dot11DisassociateStation OBJECT-TYPE SYNTAX MacAddress -- Rsyntax OCTET STRING(SIZE(6)) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute holds the MAC address from the Address 1 field of the most recently transmitted Disassociation frame. If no Disassociation frame has been transmitted, the value of this attribute shall be 0." ::= { dot11StationConfigEntry 16 } dot11DeauthenticateReason OBJECT-TYPE SYNTAX INTEGER(0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute holds the most recently transmitted Reason Code in a Deauthentication frame. If no Deauthentication frame has been transmitted, the value of this attribute shall be 0." REFERENCE "IEEE Std 802.11-2002, 7.3.1.7" ::= { dot11StationConfigEntry 17 } dot11DeauthenticateStation OBJECT-TYPE SYNTAX MacAddress -- Rsyntax OCTET STRING(SIZE(6)) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute holds the MAC address from the Address 1 field of the most recently transmitted Deauthentication frame. If no Deauthentication frame has been transmitted, the value of this attribute shall be 0." ::= { dot11StationConfigEntry 18 } dot11AuthenticateFailStatus OBJECT-TYPE SYNTAX INTEGER(0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute holds the most recently transmitted Status Code in a failed Authentication frame. If no failed Authentication frame has been transmitted, the value of this attribute shall be 0." REFERENCE "IEEE Std 802.11-2002, 7.3.1.9" ::= { dot11StationConfigEntry 19 } dot11AuthenticateFailStation OBJECT-TYPE SYNTAX MacAddress -- Rsyntax OCTET STRING(SIZE(6)) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute holds the MAC address from the Address 1 field of the most recently transmitted failed Authentication frame. If no failed Authentication frame has been transmitted, the value of this attribute shall be 0." ::= { dot11StationConfigEntry 20 } dot11MultiDomainCapabilityImplemented OBJECT-TYPE SYNTAX TruthValue -- Rsyntax INTEGER { -- true(1), -- false(2) -- } ACCESS read-write STATUS mandatory DESCRIPTION "This attribute, when TRUE, indicates that the station implementation is capable of supporting multiple regulatory domains. The capability is disabled, otherwise. The default value of this attribute is FALSE." ::= { dot11StationConfigEntry 21 } dot11MultiDomainCapabilityEnabled OBJECT-TYPE SYNTAX TruthValue -- Rsyntax INTEGER { -- true(1), -- false(2) -- } ACCESS read-write STATUS mandatory DESCRIPTION "This attribute, when TRUE, indicates that the capability of the station to operate in multiple regulatory domains is enabled. The capability is disabled, otherwise. The default value of this attribute is FALSE." ::= { dot11StationConfigEntry 22 } dot11CountryString OBJECT-TYPE SYNTAX OCTET STRING(SIZE(3)) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute identifies the country in which the station is operating. The first two octets of this string is the two character country code as described in document ISO/IEC 3166-1. The third octet shall be one of the following: 1. an ASCII space character, if the regulations under which the station is operating encompass all environments in the country, 2. an ASCII 'O' character, if the regulations under which the station is operating are for an Outdoor environment only, or 3. an ASCII 'I' character, if the regulations under which the station is operating are for an Indoor environment only." ::= { dot11StationConfigEntry 23 } dot11AuthenticationAlgorithmsTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11AuthenticationAlgorithmsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This (conceptual) table of attributes shall be a set of all the authentication algorithms supported by the stations. The following are the default values and the associated algorithm: Value = 1: Open System Value = 2: Shared Key" REFERENCE "IEEE Std 802.11-2002, 7.3.1.1" ::= { dot11smt 2 } dot11AuthenticationAlgorithmsEntry OBJECT-TYPE SYNTAX Dot11AuthenticationAlgorithmsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An Entry (conceptual row) in the Authentication Algorithms Table. ifIndex - Each IEEE 802.11 interface is represented by an ifEntry. Interface tables in this MIB module are indexed by ifIndex." INDEX { ifIndex, dot11AuthenticationAlgorithmsIndex } ::= { dot11AuthenticationAlgorithmsTable 1 } Dot11AuthenticationAlgorithmsEntry ::= SEQUENCE { dot11AuthenticationAlgorithmsIndex INTEGER, dot11AuthenticationAlgorithm INTEGER, dot11AuthenticationAlgorithmsEnable TruthValue } dot11AuthenticationAlgorithmsIndex OBJECT-TYPE SYNTAX INTEGER(0..2147483647) ACCESS not-accessible STATUS mandatory DESCRIPTION "The auxiliary variable used to identify instances of the columnar objects in the Authentication Algorithms Table." ::= { dot11AuthenticationAlgorithmsEntry 1 } dot11AuthenticationAlgorithm OBJECT-TYPE SYNTAX INTEGER { openSystem(1), sharedKey(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This attribute shall be a set of all the authentication algorithms supported by the STAs. The following are the default values and the associated algorithm. Value = 1: Open System Value = 2: Shared Key" ::= { dot11AuthenticationAlgorithmsEntry 2 } dot11AuthenticationAlgorithmsEnable OBJECT-TYPE SYNTAX TruthValue -- Rsyntax INTEGER { -- true(1), -- false(2) -- } ACCESS read-write STATUS mandatory DESCRIPTION "This attribute, when true at a station, shall enable the acceptance of the authentication algorithm described in the corresponding table entry in authentication frames received by the station that have odd authentication sequence numbers. The default value of this attribute shall be 1 for the Open System table entry and 2 for all other table entries." ::= { dot11AuthenticationAlgorithmsEntry 3 } dot11WEPDefaultKeysTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11WEPDefaultKeysEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Conceptual table for WEP default keys. This table shall contain the four WEP default secret key values corresponding to the four possible KeyID values. The WEP default secret keys are logically WRITE-ONLY. Attempts to read the entries in this table shall return unsuccessful status and values of null or zero. The default value of each WEP default key shall be null." REFERENCE "IEEE Std 802.11-2002, 8.3.2" ::= { dot11smt 3 } dot11WEPDefaultKeysEntry OBJECT-TYPE SYNTAX Dot11WEPDefaultKeysEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An Entry (conceptual row) in the WEP Default Keys Table. ifIndex - Each IEEE 802.11 interface is represented by an ifEntry. Interface tables in this MIB module are indexed by ifIndex." INDEX { ifIndex, dot11WEPDefaultKeyIndex } ::= { dot11WEPDefaultKeysTable 1 } Dot11WEPDefaultKeysEntry ::= SEQUENCE { dot11WEPDefaultKeyIndex INTEGER, dot11WEPDefaultKeyValue WEPKeytype } dot11WEPDefaultKeyIndex OBJECT-TYPE SYNTAX INTEGER(1..4) ACCESS not-accessible STATUS mandatory DESCRIPTION "The auxiliary variable used to identify instances of the columnar objects in the WEP Default Keys Table. The value of this variable is equal to the WEPDefaultKeyID + 1" ::= { dot11WEPDefaultKeysEntry 1 } dot11WEPDefaultKeyValue OBJECT-TYPE SYNTAX WEPKeytype -- Rsyntax OCTET STRING(SIZE(5)) ACCESS read-write STATUS mandatory DESCRIPTION "A WEP default secret key value." ::= { dot11WEPDefaultKeysEntry 2 } dot11WEPKeyMappingsTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11WEPKeyMappingsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Conceptual table for WEP Key Mappings. The MIB supports the ability to share a separate WEP key for each RA/TA pair. The Key Mappings Table contains zero or one entry for each MAC address and contains two fields for each entry: WEPOn and the corresponding WEP key. The WEP key mappings are logically WRITE-ONLY. Attempts to read the entries in this table shall return unsuccessful status and values of null or zero. The default value for all WEPOn fields is false." REFERENCE "IEEE Std 802.11-2002, 8.3.2" ::= { dot11smt 4 } dot11WEPKeyMappingsEntry OBJECT-TYPE SYNTAX Dot11WEPKeyMappingsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An Entry (conceptual row) in the WEP Key Mappings Table. ifIndex - Each IEEE 802.11 interface is represented by an ifEntry. Interface tables in this MIB module are indexed by ifIndex." INDEX { ifIndex, dot11WEPKeyMappingIndex } ::= { dot11WEPKeyMappingsTable 1 } Dot11WEPKeyMappingsEntry ::= SEQUENCE { dot11WEPKeyMappingIndex INTEGER, dot11WEPKeyMappingAddress MacAddress, dot11WEPKeyMappingWEPOn TruthValue, dot11WEPKeyMappingValue WEPKeytype, dot11WEPKeyMappingStatus RowStatus } dot11WEPKeyMappingIndex OBJECT-TYPE SYNTAX INTEGER(0..2147483647) ACCESS not-accessible STATUS mandatory DESCRIPTION "The auxiliary variable used to identify instances of the columnar objects in the WEP Key Mappings Table." ::= { dot11WEPKeyMappingsEntry 1 } dot11WEPKeyMappingAddress OBJECT-TYPE SYNTAX MacAddress -- Rsyntax OCTET STRING(SIZE(6)) ACCESS read-write STATUS mandatory DESCRIPTION "The MAC address of the STA for which the values from this key mapping entry are to be used." ::= { dot11WEPKeyMappingsEntry 2 } dot11WEPKeyMappingWEPOn OBJECT-TYPE SYNTAX TruthValue -- Rsyntax INTEGER { -- true(1), -- false(2) -- } ACCESS read-write STATUS mandatory DESCRIPTION "Boolean as to whether WEP is to be used when communicating with the dot11WEPKeyMappingAddress STA." ::= { dot11WEPKeyMappingsEntry 3 } dot11WEPKeyMappingValue OBJECT-TYPE SYNTAX WEPKeytype -- Rsyntax OCTET STRING(SIZE(5)) ACCESS read-write STATUS mandatory DESCRIPTION "A WEP secret key value." ::= { dot11WEPKeyMappingsEntry 4 } dot11WEPKeyMappingStatus OBJECT-TYPE SYNTAX RowStatus -- Rsyntax INTEGER { -- active(1), -- notInService(2), -- notReady(3), -- createAndGo(4), -- createAndWait(5), -- destroy(6) -- } ACCESS read-write STATUS mandatory DESCRIPTION "The status column used for creating, modifying, and deleting instances of the columnar objects in the WEP key mapping Table." DEFVAL { active } ::= { dot11WEPKeyMappingsEntry 5 } dot11PrivacyTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11PrivacyEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Group containing attributes concerned with IEEE 802.11 Privacy. Created as a table to allow multiple instantiations on an agent." ::= { dot11smt 5 } dot11PrivacyEntry OBJECT-TYPE SYNTAX Dot11PrivacyEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the dot11PrivacyTable Table. ifIndex - Each IEEE 802.11 interface is represented by an ifEntry. Interface tables in this MIB module are indexed by ifIndex." INDEX { ifIndex } ::= { dot11PrivacyTable 1 } Dot11PrivacyEntry ::= SEQUENCE { dot11PrivacyInvoked TruthValue, dot11WEPDefaultKeyID INTEGER, dot11WEPKeyMappingLength Gauge, dot11ExcludeUnencrypted TruthValue, dot11WEPICVErrorCount Counter, dot11WEPExcludedCount Counter } dot11PrivacyInvoked OBJECT-TYPE SYNTAX TruthValue -- Rsyntax INTEGER { -- true(1), -- false(2) -- } ACCESS read-write STATUS mandatory DESCRIPTION "When this attribute is true, it shall indicate that the IEEE 802.11 WEP mechanism is used for transmitting frames of type Data. The default value of this attribute shall be false." ::= { dot11PrivacyEntry 1 } dot11WEPDefaultKeyID OBJECT-TYPE SYNTAX INTEGER(0..3) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute shall indicate the use of the first, second, third, or fourth element of the WEPDefaultKeys array when set to values of zero, one, two, or three. The default value of this attribute shall be 0." REFERENCE "IEEE Std 802.11-2002, 8.3.2" ::= { dot11PrivacyEntry 2 } dot11WEPKeyMappingLength OBJECT-TYPE SYNTAX Gauge(10..4294967295) ACCESS read-write STATUS mandatory DESCRIPTION "The maximum number of tuples that dot11WEPKeyMappings can hold." REFERENCE "IEEE Std 802.11-2002, 8.3.2" ::= { dot11PrivacyEntry 3 } dot11ExcludeUnencrypted OBJECT-TYPE SYNTAX TruthValue -- Rsyntax INTEGER { -- true(1), -- false(2) -- } ACCESS read-write STATUS mandatory DESCRIPTION "When this attribute is true, the STA shall not indicate at the MAC service interface received MSDUs that have the WEP subfield of the Frame Control field equal to zero. When this attribute is false, the STA may accept MSDUs that have the WEP subfield of the Frame Control field equal to zero. The default value of this attribute shall be false." ::= { dot11PrivacyEntry 4 } dot11WEPICVErrorCount OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This counter shall increment when a frame is received with the WEP subfield of the Frame Control field set to one and the value of the ICV as received in the frame does not match the ICV value that is calculated for the contents of the received frame." ::= { dot11PrivacyEntry 5 } dot11WEPExcludedCount OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This counter shall increment when a frame is received with the WEP subfield of the Frame Control field set to zero and the value of dot11ExcludeUnencrypted causes that frame to be discarded." ::= { dot11PrivacyEntry 6 } dot11MultiDomainCapabilityTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11MultiDomainCapabilityEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This (conceptual) table of attributes for cross-domain mobility." ::= { dot11smt 7 } dot11MultiDomainCapabilityEntry OBJECT-TYPE SYNTAX Dot11MultiDomainCapabilityEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry (conceptual row) in the Multiple Domain Capability Table. IfIndex - Each IEEE 802.11 interface is represented by an ifEntry. Interface tables in this MIB are indexed by ifIndex." INDEX { ifIndex, dot11MultiDomainCapabilityIndex } ::= { dot11MultiDomainCapabilityTable 1 } Dot11MultiDomainCapabilityEntry ::= SEQUENCE { dot11MultiDomainCapabilityIndex INTEGER, dot11FirstChannelNumber INTEGER, dot11NumberofChannels INTEGER, dot11MaximumTransmitPowerLevel INTEGER } dot11MultiDomainCapabilityIndex OBJECT-TYPE SYNTAX INTEGER(0..2147483647) ACCESS not-accessible STATUS mandatory DESCRIPTION "The auxiliary variable used to identify instances of the columnar objects in the Multi Domain Capability Table." ::= { dot11MultiDomainCapabilityEntry 1 } dot11FirstChannelNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "This attribute shall indicate the value of the lowest channel number in the subband for the associated domain country string. The default value of this attribute shall be zero." ::= { dot11MultiDomainCapabilityEntry 2 } dot11NumberofChannels OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "This attribute shall indicate the value of the total number of channels allowed in the subband for the associated domain country string. The default value of this attribute shall be zero." ::= { dot11MultiDomainCapabilityEntry 3 } dot11MaximumTransmitPowerLevel OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "This attribute shall indicate the maximum transmit power, in dBm, allowed in the subband for the associated domain country string. The default value of this attribute shall be zero." ::= { dot11MultiDomainCapabilityEntry 4 } dot11OperationTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11OperationEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Group contains MAC attributes pertaining to the operation of the MAC. This has been implemented as a table in order to allow for multiple instantiations on an agent." ::= { dot11mac 1 } dot11OperationEntry OBJECT-TYPE SYNTAX Dot11OperationEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the dot11OperationEntry Table. ifIndex - Each IEEE 802.11 interface is represented by an ifEntry. Interface tables in this MIB module are indexed by ifIndex." INDEX { ifIndex } ::= { dot11OperationTable 1 } Dot11OperationEntry ::= SEQUENCE { dot11MACAddress MacAddress, dot11RTSThreshold INTEGER, dot11ShortRetryLimit INTEGER, dot11LongRetryLimit INTEGER, dot11FragmentationThreshold INTEGER, dot11MaxTransmitMSDULifetime Gauge, dot11MaxReceiveLifetime Gauge, dot11ManufacturerID DisplayString, dot11ProductID DisplayString } dot11MACAddress OBJECT-TYPE SYNTAX MacAddress -- Rsyntax OCTET STRING(SIZE(6)) ACCESS read-only STATUS mandatory DESCRIPTION "Unique MAC Address assigned to the STA." ::= { dot11OperationEntry 1 } dot11RTSThreshold OBJECT-TYPE SYNTAX INTEGER(0..2347) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute shall indicate the number of octets in an MPDU, below which an RTS/CTS handshake shall not be performed. An RTS/CTS handshake shall be performed at the beginning of any frame exchange sequence where the MPDU is of type Data or Management, the MPDU has an individual address in the Address1 field, and the length of the MPDU is greater than this threshold. (For additional details, refer to Table 21 in 9.7.) Setting this attribute to be larger than the maximum MSDU size shall have the effect of turning off the RTS/CTS handshake for frames of Data or Management type transmitted by this STA. Setting this attribute to zero shall have the effect of turning on the RTS/CTS handshake for all frames of Data or Management type transmitted by this STA. The default value of this attribute shall be 2347." ::= { dot11OperationEntry 2 } dot11ShortRetryLimit OBJECT-TYPE SYNTAX INTEGER(1..255) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute shall indicate the maximum number of transmission attempts of a frame, the length of which is less than or equal to dot11RTSThreshold, that shall be made before a failure condition is indicated. The default value of this attribute shall be 7." ::= { dot11OperationEntry 3 } dot11LongRetryLimit OBJECT-TYPE SYNTAX INTEGER(1..255) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute shall indicate the maximum number of transmission attempts of a frame, the length of which is greater than dot11RTSThreshold, that shall be made before a failure condition is indicated. The default value of this attribute shall be 4." ::= { dot11OperationEntry 4 } dot11FragmentationThreshold OBJECT-TYPE SYNTAX INTEGER(256..2346) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute shall specify the current maximum size, in octets, of the MPDU that may be delivered to the PHY. An MSDU shall be broken into fragments if its size exceeds the value of this attribute after adding MAC headers and trailers. An MSDU or MMPDU shall be fragmented when the resulting frame has an individual address in the Address1 field, and the length of the frame is larger than this threshold. The default value for this attribute shall be the lesser of 2346 or the aMPDUMaxLength of the attached PHY and shall never exceed the lesser of 2346 or the aMPDUMaxLength of the attached PHY. The value of this attribute shall never be less than 256. " ::= { dot11OperationEntry 5 } dot11MaxTransmitMSDULifetime OBJECT-TYPE SYNTAX Gauge(1..4294967295) ACCESS read-write STATUS mandatory DESCRIPTION "The MaxTransmitMSDULifetime shall be the elapsed time in TU, after the initial transmission of an MSDU, after which further attempts to transmit the MSDU shall be terminated. The default value of this attribute shall be 512." ::= { dot11OperationEntry 6 } dot11MaxReceiveLifetime OBJECT-TYPE SYNTAX Gauge(1..4294967295) ACCESS read-write STATUS mandatory DESCRIPTION "The MaxReceiveLifetime shall be the elapsed time in TU, after the initial reception of a fragmented MMPDU or MSDU, after which further attempts to reassemble the MMPDU or MSDU shall be terminated. The default value shall be 512." ::= { dot11OperationEntry 7 } dot11ManufacturerID OBJECT-TYPE SYNTAX DisplayString(SIZE(0..128)) -- Rsyntax OCTET STRING(SIZE(0..128)) ACCESS read-only STATUS mandatory DESCRIPTION "The ManufacturerID shall include, at a minimum, the name of the manufacturer. It may include additional information at the manufacturer's discretion. The default value of this attribute shall be null." ::= { dot11OperationEntry 8 } dot11ProductID OBJECT-TYPE SYNTAX DisplayString(SIZE(0..128)) -- Rsyntax OCTET STRING(SIZE(0..128)) ACCESS read-only STATUS mandatory DESCRIPTION "The ProductID shall include, at a minimum, an identifier that is unique to the manufacturer. It may include additional information at the manufacturer's discretion. The default value of this attribute shall be null." ::= { dot11OperationEntry 9 } dot11CountersTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11CountersEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Group containing attributes that are MAC counters. Implemented as a table to allow for multiple instantiations on an agent." ::= { dot11mac 2 } dot11CountersEntry OBJECT-TYPE SYNTAX Dot11CountersEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the dot11CountersEntry Table. ifIndex - Each IEEE 802.11 interface is represented by an ifEntry. Interface tables in this MIB module are indexed by ifIndex." INDEX { ifIndex } ::= { dot11CountersTable 1 } Dot11CountersEntry ::= SEQUENCE { dot11TransmittedFragmentCount Counter, dot11MulticastTransmittedFrameCount Counter, dot11FailedCount Counter, dot11RetryCount Counter, dot11MultipleRetryCount Counter, dot11FrameDuplicateCount Counter, dot11RTSSuccessCount Counter, dot11RTSFailureCount Counter, dot11ACKFailureCount Counter, dot11ReceivedFragmentCount Counter, dot11MulticastReceivedFrameCount Counter, dot11FCSErrorCount Counter, dot11TransmittedFrameCount Counter, dot11WEPUndecryptableCount Counter } dot11TransmittedFragmentCount OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This counter shall be incremented for an acknowledged MPDU with an individual address in the address 1 field or an MPDU with a multicast address in the address 1 field of type Data or Management." ::= { dot11CountersEntry 1 } dot11MulticastTransmittedFrameCount OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This counter shall increment only when the multicast bit is set in the destination MAC address of a successfully transmitted MSDU. When operating as a STA in an ESS, where these frames are directed to the AP, this implies having received an acknowledgment to all associated MPDUs." ::= { dot11CountersEntry 2 } dot11FailedCount OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This counter shall increment when an MSDU is not transmitted successfully due to the number of transmit attempts exceeding either the dot11ShortRetryLimit or dot11LongRetryLimit." ::= { dot11CountersEntry 3 } dot11RetryCount OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This counter shall increment when an MSDU is successfully transmitted after one or more retransmissions." ::= { dot11CountersEntry 4 } dot11MultipleRetryCount OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This counter shall increment when an MSDU is successfully transmitted after more than one retransmission." ::= { dot11CountersEntry 5 } dot11FrameDuplicateCount OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This counter shall increment when a frame is received that the Sequence Control field indicates is a duplicate." ::= { dot11CountersEntry 6 } dot11RTSSuccessCount OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This counter shall increment when a CTS is received in response to an RTS." ::= { dot11CountersEntry 7 } dot11RTSFailureCount OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This counter shall increment when a CTS is not received in response to an RTS." ::= { dot11CountersEntry 8 } dot11ACKFailureCount OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This counter shall increment when an ACK is not received when expected." ::= { dot11CountersEntry 9 } dot11ReceivedFragmentCount OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This counter shall be incremented for each successfully received MPDU of type Data or Management." ::= { dot11CountersEntry 10 } dot11MulticastReceivedFrameCount OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This counter shall increment when a MSDU is received with the multicast bit set in the destination MAC address." ::= { dot11CountersEntry 11 } dot11FCSErrorCount OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This counter shall increment when an FCS error is detected in a received MPDU." ::= { dot11CountersEntry 12 } dot11TransmittedFrameCount OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This counter shall increment for each successfully transmitted MSDU." ::= { dot11CountersEntry 13 } dot11WEPUndecryptableCount OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This counter shall increment when a frame is received with the WEP subfield of the Frame Control field set to one and the WEPOn value for the key mapped to the TA's MAC address indicates that the frame should not have been encrypted or that frame is discarded due to the receiving STA not implementing the privacy option." ::= { dot11CountersEntry 14 } dot11GroupAddressesTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11GroupAddressesEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A conceptual table containing a set of MAC addresses identifying the multicast addresses for which this STA will receive frames. The default value of this attribute shall be null." ::= { dot11mac 3 } dot11GroupAddressesEntry OBJECT-TYPE SYNTAX Dot11GroupAddressesEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An Entry (conceptual row) in the Group Addresses Table. ifIndex - Each IEEE 802.11 interface is represented by an ifEntry. Interface tables in this MIB module are indexed by ifIndex." INDEX { ifIndex, dot11GroupAddressesIndex } ::= { dot11GroupAddressesTable 1 } Dot11GroupAddressesEntry ::= SEQUENCE { dot11GroupAddressesIndex INTEGER, dot11Address MacAddress, dot11GroupAddressesStatus RowStatus } dot11GroupAddressesIndex OBJECT-TYPE SYNTAX INTEGER(0..2147483647) ACCESS not-accessible STATUS mandatory DESCRIPTION "The auxiliary variable used to identify instances of the columnar objects in the Group Addresses Table." ::= { dot11GroupAddressesEntry 1 } dot11Address OBJECT-TYPE SYNTAX MacAddress -- Rsyntax OCTET STRING(SIZE(6)) ACCESS read-write STATUS mandatory DESCRIPTION "MAC address identifying a multicast addresses from which this STA will receive frames." ::= { dot11GroupAddressesEntry 2 } dot11GroupAddressesStatus OBJECT-TYPE SYNTAX RowStatus -- Rsyntax INTEGER { -- active(1), -- notInService(2), -- notReady(3), -- createAndGo(4), -- createAndWait(5), -- destroy(6) -- } ACCESS read-write STATUS mandatory DESCRIPTION "The status column used for creating, modifying, and deleting instances of the columnar objects in the Group Addresses Table." DEFVAL { active } ::= { dot11GroupAddressesEntry 3 } dot11ResourceTypeIDName OBJECT-TYPE SYNTAX DisplayString(SIZE(4)) -- Rsyntax OCTET STRING(SIZE(4)) ACCESS read-only STATUS mandatory DESCRIPTION "Contains the name of the Resource Type ID managed object. The attribute is read-only and always contains the value RTID. This attribute value shall not be used as a naming attribute for any other managed object class." REFERENCE "IEEE Std 802.1F-1993, A.7" DEFVAL { "RTID" } ::= { dot11resAttribute 1 } dot11ResourceInfoTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11ResourceInfoEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Provides a means of indicating, in data readable from a managed object, information that identifies the source of the implementation." REFERENCE "IEEE Std 802.1F-1993, A.7" ::= { dot11resAttribute 2 } dot11ResourceInfoEntry OBJECT-TYPE SYNTAX Dot11ResourceInfoEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the dot11ResourceInfo Table. ifIndex - Each IEEE 802.11 interface is represented by an ifEntry. Interface tables in this MIB module are indexed by ifIndex." INDEX { ifIndex } ::= { dot11ResourceInfoTable 1 } Dot11ResourceInfoEntry ::= SEQUENCE { dot11manufacturerOUI OCTET STRING, dot11manufacturerName DisplayString, dot11manufacturerProductName DisplayString, dot11manufacturerProductVersion DisplayString } dot11manufacturerOUI OBJECT-TYPE SYNTAX OCTET STRING(SIZE(3)) ACCESS read-only STATUS mandatory DESCRIPTION "Takes the value of an organizationally unique identifier." ::= { dot11ResourceInfoEntry 1 } dot11manufacturerName OBJECT-TYPE SYNTAX DisplayString(SIZE(0..128)) -- Rsyntax OCTET STRING(SIZE(0..128)) ACCESS read-only STATUS mandatory DESCRIPTION "A printable string used to identify the manufacturer of the resource. Maximum string length is 128 octets." ::= { dot11ResourceInfoEntry 2 } dot11manufacturerProductName OBJECT-TYPE SYNTAX DisplayString(SIZE(0..128)) -- Rsyntax OCTET STRING(SIZE(0..128)) ACCESS read-only STATUS mandatory DESCRIPTION "A printable string used to identify the manufacturer's product name of the resource. Maximum string length is 128 octets." ::= { dot11ResourceInfoEntry 3 } dot11manufacturerProductVersion OBJECT-TYPE SYNTAX DisplayString(SIZE(0..128)) -- Rsyntax OCTET STRING(SIZE(0..128)) ACCESS read-only STATUS mandatory DESCRIPTION "Printable string used to identify the manufacturer's product version of the resource. Maximum string length is 128 octets." ::= { dot11ResourceInfoEntry 4 } dot11PhyOperationTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11PhyOperationEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "PHY level attributes concerned with operation. Implemented as a table indexed on ifIndex to allow for multiple instantiations on an Agent." ::= { dot11phy 1 } dot11PhyOperationEntry OBJECT-TYPE SYNTAX Dot11PhyOperationEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the dot11PhyOperation Table. ifIndex - Each IEEE 802.11 interface is represented by an ifEntry. Interface tables in this MIB module are indexed by ifIndex." INDEX { ifIndex } ::= { dot11PhyOperationTable 1 } Dot11PhyOperationEntry ::= SEQUENCE { dot11PHYType INTEGER, dot11CurrentRegDomain INTEGER, dot11TempType INTEGER } dot11PHYType OBJECT-TYPE SYNTAX INTEGER { fhss(1), dsss(2), irbaseband(3), ofdm(4), hrdsss(5) } ACCESS read-only STATUS mandatory DESCRIPTION "This is an 8-bit integer value that identifies the PHY type supported by the attached PLCP and PMD. Currently defined values and their corresponding PHY types are: FHSS 2.4 GHz = 01 , DSSS 2.4 GHz = 02, IR Baseband = 03, OFDM 5GHz = 04, HRDSSS = 05" ::= { dot11PhyOperationEntry 1 } dot11CurrentRegDomain OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The current regulatory domain this instance of the PMD is supporting. This object corresponds to one of the RegDomains listed in dot11RegDomainsSupported." ::= { dot11PhyOperationEntry 2 } dot11TempType OBJECT-TYPE SYNTAX INTEGER { tempType1(1), tempType2(2) } ACCESS read-only STATUS mandatory DESCRIPTION "There are different operating temperature requirements dependent on the anticipated environmental conditions. This attribute describes the current PHY's operating temperature range capability. Currently defined values and their corresponding temperature ranges are: Type 1 = X'01'-Commercial range of 0 to 40 degrees C, Type 2 = X'02'-Industrial range of -30 to 70 degrees C." ::= { dot11PhyOperationEntry 3 } dot11PhyAntennaTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11PhyAntennaEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Group of attributes for PhyAntenna. Implemented as a table indexed on ifIndex to allow for multiple instances on an agent." ::= { dot11phy 2 } dot11PhyAntennaEntry OBJECT-TYPE SYNTAX Dot11PhyAntennaEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the dot11PhyAntenna Table. ifIndex - Each IEEE 802.11 interface is represented by an ifEntry. Interface tables in this MIB module are indexed by ifIndex." INDEX { ifIndex } ::= { dot11PhyAntennaTable 1 } Dot11PhyAntennaEntry ::= SEQUENCE { dot11CurrentTxAntenna INTEGER, dot11DiversitySupport INTEGER, dot11CurrentRxAntenna INTEGER } dot11CurrentTxAntenna OBJECT-TYPE SYNTAX INTEGER(1..255) ACCESS read-write STATUS mandatory DESCRIPTION "The current antenna being used to transmit. This value is one of the values appearing in dot11SupportedTxAntenna. This may be used by a management agent to control which antenna is used for transmission. " ::= { dot11PhyAntennaEntry 1 } dot11DiversitySupport OBJECT-TYPE SYNTAX INTEGER { fixedlist(1), notsupported(2), dynamic(3) } ACCESS read-only STATUS mandatory DESCRIPTION "This implementation's support for diversity, encoded as: X'01'-diversity is available and is performed over the fixed list of antennas defined in dot11DiversitySelectionRx. X'02'-diversity is not supported. X'03'-diversity is supported and control of diversity is also available, in which case the attribute dot11DiversitySelectionRx can be dynamically modified by the LME." ::= { dot11PhyAntennaEntry 2 } dot11CurrentRxAntenna OBJECT-TYPE SYNTAX INTEGER(1..255) ACCESS read-write STATUS mandatory DESCRIPTION "The current antenna being used to receive, if the dot11 DiversitySupport indicates that diversity is not supported. The selected antenna shall be one of the antennae marked for receive in the dot11AntennasListTable." ::= { dot11PhyAntennaEntry 3 } dot11PhyTxPowerTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11PhyTxPowerEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Group of attributes for dot11PhyTxPowerTable. Implemented as a table indexed on STA ID to allow for multiple instances on an Agent." ::= { dot11phy 3 } dot11PhyTxPowerEntry OBJECT-TYPE SYNTAX Dot11PhyTxPowerEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the dot11PhyTxPower Table. ifIndex - Each IEEE 802.11 interface is represented by an ifEntry. Interface tables in this MIB module are indexed by ifIndex." INDEX { ifIndex } ::= { dot11PhyTxPowerTable 1 } Dot11PhyTxPowerEntry ::= SEQUENCE { dot11NumberSupportedPowerLevels INTEGER, dot11TxPowerLevel1 INTEGER, dot11TxPowerLevel2 INTEGER, dot11TxPowerLevel3 INTEGER, dot11TxPowerLevel4 INTEGER, dot11TxPowerLevel5 INTEGER, dot11TxPowerLevel6 INTEGER, dot11TxPowerLevel7 INTEGER, dot11TxPowerLevel8 INTEGER, dot11CurrentTxPowerLevel INTEGER } dot11NumberSupportedPowerLevels OBJECT-TYPE SYNTAX INTEGER(1..8) ACCESS read-only STATUS mandatory DESCRIPTION "The number of power levels supported by the PMD. This attribute can have a value of 1 to 8." ::= { dot11PhyTxPowerEntry 1 } dot11TxPowerLevel1 OBJECT-TYPE SYNTAX INTEGER(0..10000) ACCESS read-only STATUS mandatory DESCRIPTION "The transmit output power for LEVEL1 in mW. This is also the default power level." ::= { dot11PhyTxPowerEntry 2 } dot11TxPowerLevel2 OBJECT-TYPE SYNTAX INTEGER(0..10000) ACCESS read-only STATUS mandatory DESCRIPTION "The transmit output power for LEVEL2 in mW." ::= { dot11PhyTxPowerEntry 3 } dot11TxPowerLevel3 OBJECT-TYPE SYNTAX INTEGER(0..10000) ACCESS read-only STATUS mandatory DESCRIPTION "The transmit output power for LEVEL3 in mW." ::= { dot11PhyTxPowerEntry 4 } dot11TxPowerLevel4 OBJECT-TYPE SYNTAX INTEGER(0..10000) ACCESS read-only STATUS mandatory DESCRIPTION "The transmit output power for LEVEL4 in mW." ::= { dot11PhyTxPowerEntry 5 } dot11TxPowerLevel5 OBJECT-TYPE SYNTAX INTEGER(0..10000) ACCESS read-only STATUS mandatory DESCRIPTION "The transmit output power for LEVEL5 in mW." ::= { dot11PhyTxPowerEntry 6 } dot11TxPowerLevel6 OBJECT-TYPE SYNTAX INTEGER(0..10000) ACCESS read-only STATUS mandatory DESCRIPTION "The transmit output power for LEVEL6 in mW." ::= { dot11PhyTxPowerEntry 7 } dot11TxPowerLevel7 OBJECT-TYPE SYNTAX INTEGER(0..10000) ACCESS read-only STATUS mandatory DESCRIPTION "The transmit output power for LEVEL7 in mW." ::= { dot11PhyTxPowerEntry 8 } dot11TxPowerLevel8 OBJECT-TYPE SYNTAX INTEGER(0..10000) ACCESS read-only STATUS mandatory DESCRIPTION "The transmit output power for LEVEL8 in mW." ::= { dot11PhyTxPowerEntry 9 } dot11CurrentTxPowerLevel OBJECT-TYPE SYNTAX INTEGER(1..8) ACCESS read-write STATUS mandatory DESCRIPTION "The TxPowerLevel N currently being used to transmit data. Some PHYs also use this value to determine the receiver sensitivity requirements for CCA." ::= { dot11PhyTxPowerEntry 10 } dot11PhyFHSSTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11PhyFHSSEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Group of attributes for dot11PhyFHSSTable. Implemented as a table indexed on STA ID to allow for multiple instances on an Agent." ::= { dot11phy 4 } dot11PhyFHSSEntry OBJECT-TYPE SYNTAX Dot11PhyFHSSEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the dot11PhyFHSS Table. ifIndex - Each IEEE 802.11 interface is represented by an ifEntry. Interface tables in this MIB module are indexed by ifIndex." INDEX { ifIndex } ::= { dot11PhyFHSSTable 1 } Dot11PhyFHSSEntry ::= SEQUENCE { dot11HopTime INTEGER, dot11CurrentChannelNumber INTEGER, dot11MaxDwellTime INTEGER, dot11CurrentDwellTime INTEGER, dot11CurrentSet INTEGER, dot11CurrentPattern INTEGER, dot11CurrentIndex INTEGER, dot11EHCCPrimeRadix INTEGER, dot11EHCCNumberofChannelsFamilyIndex INTEGER, dot11EHCCCapabilityImplemented TruthValue, dot11EHCCCapabilityEnabled TruthValue, dot11HopAlgorithmAdopted INTEGER, dot11RandomTableFlag TruthValue, dot11NumberofHoppingSets INTEGER, dot11HopModulus INTEGER, dot11HopOffset INTEGER } dot11HopTime OBJECT-TYPE SYNTAX INTEGER(224) ACCESS read-only STATUS mandatory DESCRIPTION "The time in microseconds for the PMD to change from channel 2 to channel 80." ::= { dot11PhyFHSSEntry 1 } dot11CurrentChannelNumber OBJECT-TYPE SYNTAX INTEGER(0..200) ACCESS read-write STATUS mandatory DESCRIPTION "The current channel number of the frequency output by the RF synthesizer." ::= { dot11PhyFHSSEntry 2 } dot11MaxDwellTime OBJECT-TYPE SYNTAX INTEGER(1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The maximum time in TU that the transmitter is permitted to operate on a single channel." ::= { dot11PhyFHSSEntry 3 } dot11CurrentDwellTime OBJECT-TYPE SYNTAX INTEGER(1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "The current time in TU that the transmitter shall operate on a single channel, as set by the MAC. Default is 19 TU." ::= { dot11PhyFHSSEntry 4 } dot11CurrentSet OBJECT-TYPE SYNTAX INTEGER(1..255) ACCESS read-write STATUS mandatory DESCRIPTION "The current set of patterns the PLME is using to determine the hopping sequence. " ::= { dot11PhyFHSSEntry 5 } dot11CurrentPattern OBJECT-TYPE SYNTAX INTEGER(0..255) ACCESS read-write STATUS mandatory DESCRIPTION "The current pattern the PLME is using to determine the hop sequence." ::= { dot11PhyFHSSEntry 6 } dot11CurrentIndex OBJECT-TYPE SYNTAX INTEGER(1..255) ACCESS read-write STATUS mandatory DESCRIPTION "The current index value the PLME is using to determine the CurrentChannelNumber." ::= { dot11PhyFHSSEntry 7 } dot11EHCCPrimeRadix OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "This attribute indicates the value to be used as the prime radix (N) in the HCC and EHCC algorithms." ::= { dot11PhyFHSSEntry 8 } dot11EHCCNumberofChannelsFamilyIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "This attribute indicates the value to be used as the maximum for the family index (a) in the HCC and EHCC algorithms. The value of this field shall not be less than the prime radix minus 3 (N - 3). The valid range of allowed values is (N - 1), (N - 2), and (N - 3)." ::= { dot11PhyFHSSEntry 9 } dot11EHCCCapabilityImplemented OBJECT-TYPE SYNTAX TruthValue -- Rsyntax INTEGER { -- true(1), -- false(2) -- } ACCESS read-write STATUS mandatory DESCRIPTION "This attribute, when TRUE, indicates that the station implementation is capable of generating the HCC or EHCC algorithms for determining Hopping patterns. The capability is disabled, otherwise. The default value of this attribute is FALSE." ::= { dot11PhyFHSSEntry 10 } dot11EHCCCapabilityEnabled OBJECT-TYPE SYNTAX TruthValue -- Rsyntax INTEGER { -- true(1), -- false(2) -- } ACCESS read-write STATUS mandatory DESCRIPTION "This attribute, when TRUE, indicates that the capability of the station to operate using the HCC or EHCC algorithms for determining Hopping Patterns is enabled. The capability is disabled, otherwise. The default value of this attribute is FALSE." ::= { dot11PhyFHSSEntry 11 } dot11HopAlgorithmAdopted OBJECT-TYPE SYNTAX INTEGER { crnt(1), hopindex(2), hcc(3) } ACCESS read-write STATUS mandatory DESCRIPTION "This attribute, indicates which of the algorithms will be used to generate the Hopping Patterns. Valid values are: 1 - hopping patterns as defined in clause 14 2 - hop index method (with or without table) 3 - HCC/EHCC method" ::= { dot11PhyFHSSEntry 12 } dot11RandomTableFlag OBJECT-TYPE SYNTAX TruthValue -- Rsyntax INTEGER { -- true(1), -- false(2) -- } ACCESS read-write STATUS mandatory DESCRIPTION "This attribute, indicates that a Random Table is present when the value is True. When the value is False it indicates that a Random Table is not present and that the hop index method is to be used to determine the hopping sequence. The default value of this attribute is True." ::= { dot11PhyFHSSEntry 13 } dot11NumberofHoppingSets OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The Number of Sets field indicates the total number of sets within the hopping patterns." ::= { dot11PhyFHSSEntry 14 } dot11HopModulus OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of allowed channels for the hopping set. This is defined by the governing regulatory agency for the country code of the country in which this device is operating." ::= { dot11PhyFHSSEntry 15 } dot11HopOffset OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The next position in the hopping set." ::= { dot11PhyFHSSEntry 16 } dot11PhyDSSSTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11PhyDSSSEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Entry of attributes for dot11PhyDSSSEntry. Implemented as a table indexed on ifIndex allow for multiple instances on an Agent." ::= { dot11phy 5 } dot11PhyDSSSEntry OBJECT-TYPE SYNTAX Dot11PhyDSSSEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the dot11PhyDSSSEntry Table. ifIndex - Each IEEE 802.11 interface is represented by an ifEntry. Interface tables in this MIB module are indexed by ifIndex." INDEX { ifIndex } ::= { dot11PhyDSSSTable 1 } Dot11PhyDSSSEntry ::= SEQUENCE { dot11CurrentChannel INTEGER, dot11CCAModeSupported INTEGER, dot11CurrentCCAMode INTEGER, dot11EDThreshold INTEGER } dot11CurrentChannel OBJECT-TYPE SYNTAX INTEGER(1..14) ACCESS read-write STATUS mandatory DESCRIPTION "The current operating frequency channel of the DSSS PHY. Valid channel numbers are as defined in 15.4.6.2" ::= { dot11PhyDSSSEntry 1 } dot11CCAModeSupported OBJECT-TYPE SYNTAX INTEGER(1..7) ACCESS read-only STATUS mandatory DESCRIPTION "dot11CCAModeSupported is a bit-significant value, representing all of the CCA modes supported by the PHY. Valid values are: energy detect only (ED_ONLY) = 01, carrier sense only (CS_ONLY) = 02, carrier sense and energy detect (ED_and_CS)= 04 or the logical sum of any of these values. This attribute shall not be used to indicate the CCA modes supported by a higher rate extension PHY. Rather, the dot11HRCCAModeSupported attribute shall be used to indicate the CCA modes of the higher rate extension PHY." ::= { dot11PhyDSSSEntry 2 } dot11CurrentCCAMode OBJECT-TYPE SYNTAX INTEGER { edonly(1), csonly(2), edandcs(4), cswithtimer(8), hrcsanded(16) } ACCESS read-write STATUS mandatory DESCRIPTION "The current CCA method in operation. Valid values are: energy detect only (edonly) = 01, carrier sense only (csonly) = 02, carrier sense and energy detect (edandcs)= 04 carrier sense with timer (cswithtimer)= 08 high rate carrier sense and energy detect (hrcsanded)=16." ::= { dot11PhyDSSSEntry 3 } dot11EDThreshold OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The current Energy Detect Threshold being used by the DSSS PHY." ::= { dot11PhyDSSSEntry 4 } dot11PhyIRTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11PhyIREntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Group of attributes for dot11PhyIRTable. Implemented as a table indexed on ifIndex to allow for multiple instances on an Agent." ::= { dot11phy 6 } dot11PhyIREntry OBJECT-TYPE SYNTAX Dot11PhyIREntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the dot11PhyIR Table. ifIndex - Each IEEE 802.11 interface is represented by an ifEntry. Interface tables in this MIB module are indexed by ifIndex." INDEX { ifIndex } ::= { dot11PhyIRTable 1 } Dot11PhyIREntry ::= SEQUENCE { dot11CCAWatchdogTimerMax INTEGER, dot11CCAWatchdogCountMax INTEGER, dot11CCAWatchdogTimerMin INTEGER, dot11CCAWatchdogCountMin INTEGER } dot11CCAWatchdogTimerMax OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "This parameter, together with CCAWatchdogCountMax, determines when energy detected in the channel can be ignored." ::= { dot11PhyIREntry 1 } dot11CCAWatchdogCountMax OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "This parameter, together with CCAWatchdogTimerMax, determines when energy detected in the channel can be ignored." ::= { dot11PhyIREntry 2 } dot11CCAWatchdogTimerMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The minimum value to which CCAWatchdogTimerMax can be set." ::= { dot11PhyIREntry 3 } dot11CCAWatchdogCountMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The minimum value to which CCAWatchdogCount can be set." ::= { dot11PhyIREntry 4 } dot11RegDomainsSupportedTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11RegDomainsSupportedEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "There are different operational requirements dependent on the regulatory domain. This attribute list describes the regulatory domains the PLCP and PMD support in this implementation. Currently defined values and their corresponding Regulatory Domains are: FCC (USA) = X'10', DOC (Canada) = X'20', ETSI (most of Europe) = X'30', Spain = X'31', France = X'32', MKK (Japan) = X'40', Others = X'00' " ::= { dot11phy 7 } dot11RegDomainsSupportedEntry OBJECT-TYPE SYNTAX Dot11RegDomainsSupportedEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the dot11RegDomainsSupportedTable. ifIndex - Each IEEE 802.11 interface is represented by an ifEntry. Interface tables in this MIB module are indexed by ifIndex." INDEX { ifIndex, dot11RegDomainsSupportedIndex } ::= { dot11RegDomainsSupportedTable 1 } Dot11RegDomainsSupportedEntry ::= SEQUENCE { dot11RegDomainsSupportedIndex INTEGER, dot11RegDomainsSupportedValue INTEGER } dot11RegDomainsSupportedIndex OBJECT-TYPE SYNTAX INTEGER(0..2147483647) ACCESS not-accessible STATUS mandatory DESCRIPTION "The auxiliary variable used to identify instances of the columnar objects in the RegDomainsSupport Table." ::= { dot11RegDomainsSupportedEntry 1 } dot11RegDomainsSupportedValue OBJECT-TYPE SYNTAX INTEGER { fcc(16), doc(32), etsi(48), spain(49), france(50), mkk(64) } ACCESS read-only STATUS mandatory DESCRIPTION "There are different operational requirements dependent on the regulatory domain. This attribute list describes the regulatory domains the PLCP and PMD support in this implementation. Currently defined values and their corresponding Regulatory Domains are: FCC (USA) = X'10', DOC (Canada) = X'20', ETSI (most of Europe) = X'30', Spain = X'31', France = X'32', MKK (Japan) = X'40' " ::= { dot11RegDomainsSupportedEntry 2 } dot11AntennasListTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11AntennasListEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table represents the list of antennae. An antenna can be marked to be capable of transmitting, receiving, and/or for participation in receive diversity. Each entry in this table represents a single antenna with its properties. The maximum number of antennae that can be contained in this table is 255." ::= { dot11phy 8 } dot11AntennasListEntry OBJECT-TYPE SYNTAX Dot11AntennasListEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the dot11AntennasListTable, representing the properties of a single antenna. ifIndex - Each IEEE 802.11 interface is represented by an ifEntry. Interface tables in this MIB module are indexed by ifIndex." INDEX { ifIndex, dot11AntennaListIndex } ::= { dot11AntennasListTable 1 } Dot11AntennasListEntry ::= SEQUENCE { dot11AntennaListIndex INTEGER, dot11SupportedTxAntenna TruthValue, dot11SupportedRxAntenna TruthValue, dot11DiversitySelectionRx TruthValue } dot11AntennaListIndex OBJECT-TYPE SYNTAX INTEGER(1..255) ACCESS not-accessible STATUS mandatory DESCRIPTION "The unique index of an antenna which is used to identify the columnar objects in the dot11AntennasList Table." ::= { dot11AntennasListEntry 1 } dot11SupportedTxAntenna OBJECT-TYPE SYNTAX TruthValue -- Rsyntax INTEGER { -- true(1), -- false(2) -- } ACCESS read-write STATUS mandatory DESCRIPTION "When true, this object indicates that the antenna represented by dot11AntennaIndex can be used as a transmit antenna." ::= { dot11AntennasListEntry 2 } dot11SupportedRxAntenna OBJECT-TYPE SYNTAX TruthValue -- Rsyntax INTEGER { -- true(1), -- false(2) -- } ACCESS read-write STATUS mandatory DESCRIPTION "When true, this object indicates that the antenna represented by the dot11AntennaIndex xan be used as a receive antenna." ::= { dot11AntennasListEntry 3 } dot11DiversitySelectionRx OBJECT-TYPE SYNTAX TruthValue -- Rsyntax INTEGER { -- true(1), -- false(2) -- } ACCESS read-write STATUS mandatory DESCRIPTION "When true, this object indicates that the antenna represented by dot11AntennaIndex can be used for receive diversity. This object may only be true if the antenna can be used as a receive antenna, as indicated by dot11SupportedRxAntenna." ::= { dot11AntennasListEntry 4 } dot11SupportedDataRatesTxTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11SupportedDataRatesTxEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The Transmit bit rates supported by the PLCP and PMD, represented by a count from X'02-X'7f, corresponding to data rates in increments of 500kbit/s from 1 Mbit/s to 63.5 Mbit/s subject to limitations of each individual PHY." ::= { dot11phy 9 } dot11SupportedDataRatesTxEntry OBJECT-TYPE SYNTAX Dot11SupportedDataRatesTxEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An Entry (conceptual row) in the dot11SupportedDataRatesTx Table. ifIndex - Each IEEE 802.11 interface is represented by an ifEntry. Interface tables in this MIB module are indexed by ifIndex." INDEX { ifIndex, dot11SupportedDataRatesTxIndex } ::= { dot11SupportedDataRatesTxTable 1 } Dot11SupportedDataRatesTxEntry ::= SEQUENCE { dot11SupportedDataRatesTxIndex INTEGER, dot11SupportedDataRatesTxValue INTEGER } dot11SupportedDataRatesTxIndex OBJECT-TYPE SYNTAX INTEGER(1..8) ACCESS not-accessible STATUS mandatory DESCRIPTION "Index object which identifies which data rate to access. Range is 1..8." ::= { dot11SupportedDataRatesTxEntry 1 } dot11SupportedDataRatesTxValue OBJECT-TYPE SYNTAX INTEGER(2..127) ACCESS read-only STATUS mandatory DESCRIPTION "The Transmit bit rates supported by the PLCP and PMD, represented by a count from X'02-X'7f, corresponding to data rates in increments of 500kbit/s from 1 Mbit/s to 63.5 Mbit/s subject to limitations of each individual PHY." ::= { dot11SupportedDataRatesTxEntry 2 } dot11SupportedDataRatesRxTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11SupportedDataRatesRxEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The receive bit rates supported by the PLCP and PMD, represented by a count from X'002-X'7f, corresponding to data rates in increments of 500kbit/s from 1 Mbit/s to 63.5 Mbit/s." ::= { dot11phy 10 } dot11SupportedDataRatesRxEntry OBJECT-TYPE SYNTAX Dot11SupportedDataRatesRxEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An Entry (conceptual row) in the dot11SupportedDataRatesRx Table. ifIndex - Each IEEE 802.11 interface is represented by an ifEntry. Interface tables in this MIB module are indexed by ifIndex." INDEX { ifIndex, dot11SupportedDataRatesRxIndex } ::= { dot11SupportedDataRatesRxTable 1 } Dot11SupportedDataRatesRxEntry ::= SEQUENCE { dot11SupportedDataRatesRxIndex INTEGER, dot11SupportedDataRatesRxValue INTEGER } dot11SupportedDataRatesRxIndex OBJECT-TYPE SYNTAX INTEGER(1..8) ACCESS not-accessible STATUS mandatory DESCRIPTION "Index object which identifies which data rate to access. Range is 1..8." ::= { dot11SupportedDataRatesRxEntry 1 } dot11SupportedDataRatesRxValue OBJECT-TYPE SYNTAX INTEGER(2..127) ACCESS read-only STATUS mandatory DESCRIPTION "The receive bit rates supported by the PLCP and PMD, represented by a count from X'02-X'7f, corresponding to data rates in increments of 500kbit/s from 1 Mbit/s to 63.5 Mbit/s." ::= { dot11SupportedDataRatesRxEntry 2 } dot11PhyOFDMTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11PhyOFDMEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Group of attributes for dot11PhyOFDMTable. Implemented as a table indexed on ifindex to allow for multiple instances on an Agent." ::= { dot11phy 11 } dot11PhyOFDMEntry OBJECT-TYPE SYNTAX Dot11PhyOFDMEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the dot11PhyOFDM Table. ifIndex - Each IEEE 802.11 interface is represented by an ifEntry. Interface tables in this MIB module are indexed by ifIndex." INDEX { ifIndex } ::= { dot11PhyOFDMTable 1 } Dot11PhyOFDMEntry ::= SEQUENCE { dot11CurrentFrequency INTEGER, dot11TIThreshold INTEGER, dot11FrequencyBandsSupported INTEGER } dot11CurrentFrequency OBJECT-TYPE SYNTAX INTEGER(0..99) ACCESS read-write STATUS mandatory DESCRIPTION "The number of the current operating frequency channel of the OFDM PHY." ::= { dot11PhyOFDMEntry 1 } dot11TIThreshold OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The Threshold being used to detect a busy medium (frequency). CCA shall report a busy medium upon detecting the RSSI above this threshold." ::= { dot11PhyOFDMEntry 2 } dot11FrequencyBandsSupported OBJECT-TYPE SYNTAX INTEGER(1..7) ACCESS read-only STATUS mandatory DESCRIPTION "The capability of the OFDM PHY implementation to operate in the three U-NII bands. Coded as an integer value of a three bit field as follows: bit 0 .. capable of operating in the lower (5.15-5.25 GHz) U-NII band bit 1 .. capable of operating in the middle (5.25-5.35 GHz) U-NII band bit 2 .. capable of operating in the upper (5.725-5.825 GHz) U-NII band For example, for an implementation capable of operating in the lower and mid bands this attribute would take the value 3." ::= { dot11PhyOFDMEntry 3 } dot11PhyHRDSSSTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11PhyHRDSSSEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Entry of attributes for dot11PhyHRDSSSEntry. Implemented as a table indexed on ifIndex to allow for multiple instances on an Agent." ::= { dot11phy 12 } dot11PhyHRDSSSEntry OBJECT-TYPE SYNTAX Dot11PhyHRDSSSEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the dot11PhyHRDSSSEntry Table. ifIndex - Each IEEE 802.11 interface is represented by an ifEntry. Interface tables in this MIB module are indexed by ifIndex." INDEX { ifIndex } ::= { dot11PhyHRDSSSTable 1 } Dot11PhyHRDSSSEntry ::= SEQUENCE { dot11ShortPreambleOptionImplemented TruthValue, dot11PBCCOptionImplemented TruthValue, dot11ChannelAgilityPresent TruthValue, dot11ChannelAgilityEnabled TruthValue, dot11HRCCAModeSupported INTEGER } dot11ShortPreambleOptionImplemented OBJECT-TYPE SYNTAX TruthValue -- Rsyntax INTEGER { -- true(1), -- false(2) -- } ACCESS read-only STATUS mandatory DESCRIPTION "This attribute, when true, shall indicate that the short preamble option as defined in subclause 18.2.2.2 is implemented. The default value of this attribute shall be false." ::= { dot11PhyHRDSSSEntry 1 } dot11PBCCOptionImplemented OBJECT-TYPE SYNTAX TruthValue -- Rsyntax INTEGER { -- true(1), -- false(2) -- } ACCESS read-only STATUS mandatory DESCRIPTION "This attribute, when true, shall indicate that the PBCC modulation option as defined in subclause 18.4.6.6 is implemented. The default value of this attribute shall be false." ::= { dot11PhyHRDSSSEntry 2 } dot11ChannelAgilityPresent OBJECT-TYPE SYNTAX TruthValue -- Rsyntax INTEGER { -- true(1), -- false(2) -- } ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates that the PHY is capable of channel agility." ::= { dot11PhyHRDSSSEntry 3 } dot11ChannelAgilityEnabled OBJECT-TYPE SYNTAX TruthValue -- Rsyntax INTEGER { -- true(1), -- false(2) -- } ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates that the PHY channel agility functionality is enabled." ::= { dot11PhyHRDSSSEntry 4 } dot11HRCCAModeSupported OBJECT-TYPE SYNTAX INTEGER(1..31) ACCESS read-only STATUS mandatory DESCRIPTION "dot11HRCCAModeSupported is a bit-significant value, representing all of the CCA modes supported by the PHY. Valid values are: energy detect only (ED_ONLY) = 01, carrier sense only (CS_ONLY) = 02, carrier sense and energy detect (ED_and_CS)= 04, carrier sense with timer (CS_and_Timer)= 08, high rate carrier sense and energy detect (HRCS_and_ED)= 16 or the logical sum of any of these values. In the high rate extension PHY, this attribute shall be used in preference to the dot11CCAModeSupported attribute." ::= { dot11PhyHRDSSSEntry 5 } dot11HoppingPatternTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11HoppingPatternEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The (conceptual) table of attributes necessary for a frequency hopping implementation to be able to create the hopping sequences necessary to operate in the subband for the associated domain country string." ::= { dot11phy 13 } dot11HoppingPatternEntry OBJECT-TYPE SYNTAX Dot11HoppingPatternEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry (conceptual row) in the Hopping Pattern Table that indicates the random hopping sequence to be followed. IfIndex - Each IEEE 802.11 interface is represented by an ifEntry. Interface tables in this MIB are indexed by ifIndex." INDEX { ifIndex, dot11HoppingPatternIndex } ::= { dot11HoppingPatternTable 1 } Dot11HoppingPatternEntry ::= SEQUENCE { dot11HoppingPatternIndex INTEGER, dot11RandomTableFieldNumber INTEGER } dot11HoppingPatternIndex OBJECT-TYPE SYNTAX INTEGER(0..2147483647) ACCESS not-accessible STATUS mandatory DESCRIPTION "The auxiliary variable used to identify instances of the columnar objects in the Hopping Pattern Table." ::= { dot11HoppingPatternEntry 1 } dot11RandomTableFieldNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "This attribute shall indicate the value of the starting channel number in the hopping sequence of the subband for the associated domain country string. The default value of this attribute shall be zero." ::= { dot11HoppingPatternEntry 2 } dot11Disassociate TRAP-TYPE -- Reverse mappable trap ENTERPRISE dot11SMTnotification VARIABLES { ifIndex, dot11DisassociateReason, dot11DisassociateStation } -- Status -- mandatory DESCRIPTION "The disassociate notification shall be sent when the STA sends a Disassociation frame. The value of the notification shall include the MAC address of the MAC to which the Disassociation frame was sent and the reason for the disassociation. ifIndex - Each IEEE 802.11 interface is represented by an ifEntry. Interface tables in this MIB module are indexed by ifIndex." ::= 1 dot11Deauthenticate TRAP-TYPE -- Reverse mappable trap ENTERPRISE dot11SMTnotification VARIABLES { ifIndex, dot11DeauthenticateReason, dot11DeauthenticateStation } -- Status -- mandatory DESCRIPTION "The deauthenticate notification shall be sent when the STA sends a Deauthentication frame. The value of the notification shall include the MAC address of the MAC to which the Deauthentication frame was sent and the reason for the deauthentication. ifIndex - Each IEEE 802.11 interface is represented by an ifEntry. Interface tables in this MIB module are indexed by ifIndex." ::= 2 dot11AuthenticateFail TRAP-TYPE -- Reverse mappable trap ENTERPRISE dot11SMTnotification VARIABLES { ifIndex, dot11AuthenticateFailStatus, dot11AuthenticateFailStation } -- Status -- mandatory DESCRIPTION "The authenticate failure notification shall be sent when the STA sends an Authentication frame with a status code other than 'successful'. The value of the notification shall include the MAC address of the MAC to which the Authentication frame was sent and the reason for the authentication failure. ifIndex - Each IEEE 802.11 interface is represented by an ifEntry. Interface tables in this MIB module are indexed by ifIndex." ::= 3 dot11SMTbase OBJECT IDENTIFIER ::= { dot11Groups 1 } -- OBJECT-GROUP -- Status -- deprecated -- Descr -- The SMT object class provides the necessary support at the -- STA to manage the processes in the STA such that the STA may -- work cooperatively as a part of an IEEE 802.11 network. -- objects -- dot11StationID, dot11MediumOccupancyLimit, dot11CFPollable, -- dot11CFPPeriod, dot11CFPMaxDuration, -- dot11AuthenticationResponseTimeOut, -- dot11PrivacyOptionImplemented, dot11PowerManagementMode, -- dot11DesiredSSID, dot11DesiredBSSType, -- dot11OperationalRateSet, dot11BeaconPeriod, dot11DTIMPeriod, -- dot11AssociationResponseTimeOut dot11SMTprivacy OBJECT IDENTIFIER ::= { dot11Groups 2 } -- OBJECT-GROUP -- Status -- mandatory -- Descr -- The SMTPrivacy package is a set of attributes that shall be -- present if WEP is implemented in the STA. -- objects -- dot11PrivacyInvoked, dot11WEPKeyMappingLength, -- dot11ExcludeUnencrypted, dot11WEPICVErrorCount, -- dot11WEPExcludedCount, dot11WEPDefaultKeyID, -- dot11WEPDefaultKeyValue, dot11WEPKeyMappingWEPOn, -- dot11WEPKeyMappingValue, dot11WEPKeyMappingAddress, -- dot11WEPKeyMappingStatus dot11MACbase OBJECT IDENTIFIER ::= { dot11Groups 3 } -- OBJECT-GROUP -- Status -- mandatory -- Descr -- The MAC object class provides the necessary support for the -- access control, generation, and verification of frame check -- sequences (FCSs), and proper delivery of valid data to upper -- layers. -- objects -- dot11MACAddress, dot11Address, dot11GroupAddressesStatus, -- dot11RTSThreshold, dot11ShortRetryLimit, dot11LongRetryLimit, -- dot11FragmentationThreshold, dot11MaxTransmitMSDULifetime, -- dot11MaxReceiveLifetime, dot11ManufacturerID, dot11ProductID dot11MACStatistics OBJECT IDENTIFIER ::= { dot11Groups 4 } -- OBJECT-GROUP -- Status -- mandatory -- Descr -- The MACStatistics package provides extended statistical -- information on the operation of the MAC. This -- package is completely optional. -- objects -- dot11RetryCount, dot11MultipleRetryCount, -- dot11RTSSuccessCount, dot11RTSFailureCount, -- dot11ACKFailureCount, dot11FrameDuplicateCount dot11ResourceTypeID OBJECT IDENTIFIER ::= { dot11Groups 5 } -- OBJECT-GROUP -- Status -- mandatory -- Descr -- Attributes used to identify a STA, its manufacturer, -- and various product names and versions. -- objects -- dot11ResourceTypeIDName, dot11manufacturerOUI, -- dot11manufacturerName, dot11manufacturerProductName, -- dot11manufacturerProductVersion dot11SmtAuthenticationAlgorithms OBJECT IDENTIFIER ::= { dot11Groups 6 } -- OBJECT-GROUP -- Status -- mandatory -- Descr -- Authentication Algorithm Table. -- objects -- dot11AuthenticationAlgorithm, -- dot11AuthenticationAlgorithmsEnable dot11PhyOperationComplianceGroup OBJECT IDENTIFIER ::= { dot11Groups 7 } -- OBJECT-GROUP -- Status -- mandatory -- Descr -- PHY layer operations attributes. -- objects -- dot11PHYType, dot11CurrentRegDomain, dot11TempType dot11PhyAntennaComplianceGroup OBJECT IDENTIFIER ::= { dot11Groups 8 } -- OBJECT-GROUP -- Status -- mandatory -- Descr -- Attributes for Data Rates for IEEE 802.11. -- objects -- dot11CurrentTxAntenna, dot11DiversitySupport, -- dot11CurrentRxAntenna dot11PhyTxPowerComplianceGroup OBJECT IDENTIFIER ::= { dot11Groups 9 } -- OBJECT-GROUP -- Status -- mandatory -- Descr -- Attributes for Control and Management of transmit power. -- objects -- dot11NumberSupportedPowerLevels, dot11TxPowerLevel1, -- dot11TxPowerLevel2, dot11TxPowerLevel3, dot11TxPowerLevel4, -- dot11TxPowerLevel5, dot11TxPowerLevel6, dot11TxPowerLevel7, -- dot11TxPowerLevel8, dot11CurrentTxPowerLevel dot11PhyFHSSComplianceGroup OBJECT IDENTIFIER ::= { dot11Groups 10 } -- OBJECT-GROUP -- Status -- mandatory -- Descr -- Attributes that configure the Frequency Hopping for IEEE -- 802.11. -- objects -- dot11HopTime, dot11CurrentChannelNumber, dot11MaxDwellTime, -- dot11CurrentDwellTime, dot11CurrentSet, dot11CurrentPattern, -- dot11CurrentIndex dot11PhyDSSSComplianceGroup OBJECT IDENTIFIER ::= { dot11Groups 11 } -- OBJECT-GROUP -- Status -- mandatory -- Descr -- Attributes that configure the DSSS for IEEE 802.11. -- objects -- dot11CurrentChannel, dot11CCAModeSupported, -- dot11CurrentCCAMode, dot11EDThreshold dot11PhyIRComplianceGroup OBJECT IDENTIFIER ::= { dot11Groups 12 } -- OBJECT-GROUP -- Status -- mandatory -- Descr -- Attributes that configure the baseband IR for IEEE 802.11. -- objects -- dot11CCAWatchdogTimerMax, dot11CCAWatchdogCountMax, -- dot11CCAWatchdogTimerMin, dot11CCAWatchdogCountMin dot11PhyRegDomainsSupportGroup OBJECT IDENTIFIER ::= { dot11Groups 13 } -- OBJECT-GROUP -- Status -- mandatory -- Descr -- Attributes that specify the supported Regulation Domains. -- objects -- dot11RegDomainsSupportedValue dot11PhyAntennasListGroup OBJECT IDENTIFIER ::= { dot11Groups 14 } -- OBJECT-GROUP -- Status -- mandatory -- Descr -- Attributes that specify the supported Regulation Domains. -- objects -- dot11SupportedTxAntenna, dot11SupportedRxAntenna, -- dot11DiversitySelectionRx dot11PhyRateGroup OBJECT IDENTIFIER ::= { dot11Groups 15 } -- OBJECT-GROUP -- Status -- mandatory -- Descr -- Attributes for Data Rates for IEEE 802.11. -- objects -- dot11SupportedDataRatesTxValue, -- dot11SupportedDataRatesRxValue dot11CountersGroup OBJECT IDENTIFIER ::= { dot11Groups 16 } -- OBJECT-GROUP -- Status -- mandatory -- Descr -- Attributes from the dot11CountersGroup that are not described -- in the dot11MACStatistics group. These objects are -- mandatory. -- objects -- dot11TransmittedFragmentCount, -- dot11MulticastTransmittedFrameCount, dot11FailedCount, -- dot11ReceivedFragmentCount, dot11MulticastReceivedFrameCount, -- dot11FCSErrorCount, dot11WEPUndecryptableCount, -- dot11TransmittedFrameCount dot11SMTbase2 OBJECT IDENTIFIER ::= { dot11Groups 18 } -- OBJECT-GROUP -- Status -- mandatory -- Descr -- The SMTbase2 object class provides the necessary support at the -- STA to manage the processes in the STA such that the STA may -- work cooperatively as a part of an IEEE 802.11 network. -- objects -- dot11MediumOccupancyLimit, dot11CFPollable, dot11CFPPeriod, -- dot11CFPMaxDuration, dot11AuthenticationResponseTimeOut, -- dot11PrivacyOptionImplemented, dot11PowerManagementMode, -- dot11DesiredSSID, dot11DesiredBSSType, -- dot11OperationalRateSet, dot11BeaconPeriod, dot11DTIMPeriod, -- dot11AssociationResponseTimeOut, dot11DisassociateReason, -- dot11DisassociateStation, dot11DeauthenticateReason, -- dot11DeauthenticateStation, dot11AuthenticateFailStatus, -- dot11AuthenticateFailStation dot11PhyOFDMComplianceGroup OBJECT IDENTIFIER ::= { dot11Groups 19 } -- OBJECT-GROUP -- Status -- mandatory -- Descr -- Attributes that configure the OFDM for IEEE 802.11. -- objects -- dot11CurrentFrequency, dot11TIThreshold, -- dot11FrequencyBandsSupported dot11SMTbase3 OBJECT IDENTIFIER ::= { dot11Groups 20 } -- OBJECT-GROUP -- Status -- mandatory -- Descr -- The SMTbase3 object class provides the necessary support at the -- STA to manage the processes in the STA such that the STA may -- work cooperatively as a part of an IEEE 802.11 network, when the STA -- is capable of multi-domain operation. This object group should be -- implemented when the multi-domain capability option is implemented. -- objects -- dot11MediumOccupancyLimit, dot11CFPollable, dot11CFPPeriod, -- dot11CFPMaxDuration, dot11AuthenticationResponseTimeOut, -- dot11PrivacyOptionImplemented, dot11PowerManagementMode, -- dot11DesiredSSID, dot11DesiredBSSType, -- dot11OperationalRateSet, dot11BeaconPeriod, dot11DTIMPeriod, -- dot11AssociationResponseTimeOut, dot11DisassociateReason, -- dot11DisassociateStation, dot11DeauthenticateReason, -- dot11DeauthenticateStation, dot11AuthenticateFailStatus, -- dot11AuthenticateFailStation, -- dot11MultiDomainCapabilityImplemented, -- dot11MultiDomainCapabilityEnabled, dot11CountryString dot11MultiDomainCapabilityGroup OBJECT IDENTIFIER ::= { dot11Groups 21 } -- OBJECT-GROUP -- Status -- mandatory -- Descr -- The dot11MultiDomainCapabilityGroup object class provides -- the objects necessary to manage the channels usable by a STA, -- when the multi-domain capability option is implemented. -- objects -- dot11FirstChannelNumber, dot11NumberofChannels, -- dot11MaximumTransmitPowerLevel dot11PhyFHSSComplianceGroup2 OBJECT IDENTIFIER ::= { dot11Groups 22 } -- OBJECT-GROUP -- Status -- mandatory -- Descr -- Attributes that configure the Frequency Hopping for IEEE -- 802.11 when multi-domain capability option is implemented. -- objects -- dot11HopTime, dot11CurrentChannelNumber, dot11MaxDwellTime, -- dot11CurrentDwellTime, dot11CurrentSet, dot11CurrentPattern, -- dot11CurrentIndex, dot11EHCCPrimeRadix, -- dot11EHCCNumberofChannelsFamilyIndex, -- dot11EHCCCapabilityImplemented, dot11EHCCCapabilityEnabled, -- dot11HopAlgorithmAdopted, dot11RandomTableFlag, -- dot11NumberofHoppingSets, dot11HopModulus, dot11HopOffset, -- dot11RandomTableFieldNumber dot11PhyHRDSSSComplianceGroup OBJECT IDENTIFIER ::= { dot11Groups 23 } -- OBJECT-GROUP -- Status -- mandatory -- Descr -- Attributes that configure the HRDSSS for IEEE 802.11. -- objects -- dot11CurrentChannel, dot11CCAModeSupported, -- dot11CurrentCCAMode, dot11EDThreshold, -- dot11ShortPreambleOptionImplemented, -- dot11PBCCOptionImplemented, dot11ChannelAgilityPresent, -- dot11ChannelAgilityEnabled, dot11HRCCAModeSupported dot11NotificationGroup OBJECT IDENTIFIER ::= { dot11Groups 17 } -- NOTIFICATION-GROUP -- Status -- mandatory -- Descr -- IEEE 802.11 notifications -- notifications -- dot11Disassociate, dot11Deauthenticate, dot11AuthenticateFail dot11Compliance OBJECT IDENTIFIER ::= { dot11Compliances 1 } -- MODULE-COMPLIANCE -- Status -- mandatory -- Descr -- The compliance statement for SNMPv2 entities -- that implement the IEEE 802.11 MIB. -- Module -- >>current<< -- MandGroup -- dot11SMTbase2 -- MandGroup -- dot11MACbase -- MandGroup -- dot11CountersGroup -- MandGroup -- dot11SmtAuthenticationAlgorithms -- MandGroup -- dot11ResourceTypeID -- MandGroup -- dot11PhyOperationComplianceGroup -- OptGroup -- dot11PhyDSSSComplianceGroup -- OptGroup -- dot11PhyIRComplianceGroup -- OptGroup -- dot11PhyFHSSComplianceGroup -- OptGroup -- dot11PhyOFDMComplianceGroup -- OptGroup -- dot11PhyHRDSSSComplianceGroup END