-- MIB file created 20-Jan-2009 11:49:40, by -- SMICng version 2.2.11-beta(PRO)(Solaris), January 20, 2001. Enterprise key cisco.com POWER-ETHERNET-MIB DEFINITIONS ::= BEGIN -- From file: "POWER-ETHERNET-MIB.my" -- Compile options "4 7 F H N O W 03 06 0B 0G 0N 0T" IMPORTS mib-2 FROM SNMPv2-SMI-v1 TruthValue FROM SNMPv2-TC-v1 SnmpAdminString FROM SNMP-FRAMEWORK-MIB Counter, Gauge FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212 TRAP-TYPE FROM RFC-1215; powerEthernetMIB OBJECT IDENTIFIER ::= { mib-2 105 } -- MODULE-IDENTITY -- LastUpdated -- 200311240000Z -- OrgName -- IETF Ethernet Interfaces and Hub MIB -- Working Group -- ContactInfo -- -- WG Charter: -- http://www.ietf.org/html.charters/hubmib-charter.html -- -- Mailing lists: -- General Discussion: hubmib@ietf.org -- To Subscribe: hubmib-requests@ietf.org -- In Body: subscribe your_email_address -- -- Chair: Dan Romascanu -- Avaya -- Tel: +972-3-645-8414 -- Email: dromasca@avaya.com -- -- Editor: Avi Berger -- PowerDsine Inc. -- Tel: 972-9-7755100 Ext 307 -- Fax: 972-9-7755120 -- E-mail: avib@PowerDsine.com -- Descr -- The MIB module for managing Power Source Equipment -- (PSE) working according to the IEEE 802.af Powered -- Ethernet (DTE Power via MDI) standard. -- -- The following terms are used throughout this -- MIB module. For complete formal definitions, -- the IEEE 802.3 standards should be consulted -- wherever possible: -- -- Group - A recommended, but optional, entity -- defined by the IEEE 802.3 management standard, -- in order to support a modular numbering scheme. -- The classical example allows an implementor to -- represent field-replaceable units as groups of -- ports, with the port numbering matching the -- modular hardware implementation. -- -- Port - This entity identifies the port within the group -- for which this entry contains information. The numbering -- scheme for ports is implementation specific. -- -- Copyright (c) The Internet Society (2003). This version -- of this MIB module is part of RFC 3621; See the RFC -- itself for full legal notices. -- RevDate -- 200311240000Z -- RevDescr -- Initial version, published as RFC 3621. pethNotifications OBJECT IDENTIFIER ::= { powerEthernetMIB 0 } pethObjects OBJECT IDENTIFIER ::= { powerEthernetMIB 1 } pethConformance OBJECT IDENTIFIER ::= { powerEthernetMIB 2 } pethMainPseObjects OBJECT IDENTIFIER ::= { pethObjects 3 } pethNotificationControl OBJECT IDENTIFIER ::= { pethObjects 4 } pethCompliances OBJECT IDENTIFIER ::= { pethConformance 1 } pethGroups OBJECT IDENTIFIER ::= { pethConformance 2 } pethPsePortTable OBJECT-TYPE SYNTAX SEQUENCE OF PethPsePortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of objects that display and control the power characteristics of power Ethernet ports on a Power Source Entity (PSE) device. This group will be implemented in managed power Ethernet switches and mid-span devices. Values of all read-write objects in this table are persistent at restart/reboot." ::= { pethObjects 1 } pethPsePortEntry OBJECT-TYPE SYNTAX PethPsePortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A set of objects that display and control the power characteristics of a power Ethernet PSE port." INDEX { pethPsePortGroupIndex, pethPsePortIndex } ::= { pethPsePortTable 1 } PethPsePortEntry ::= SEQUENCE { pethPsePortGroupIndex INTEGER, pethPsePortIndex INTEGER, pethPsePortAdminEnable TruthValue, pethPsePortPowerPairsControlAbility TruthValue, pethPsePortPowerPairs INTEGER, pethPsePortDetectionStatus INTEGER, pethPsePortPowerPriority INTEGER, pethPsePortMPSAbsentCounter Counter, pethPsePortType SnmpAdminString, pethPsePortPowerClassifications INTEGER, pethPsePortInvalidSignatureCounter Counter, pethPsePortPowerDeniedCounter Counter, pethPsePortOverLoadCounter Counter, pethPsePortShortCounter Counter } pethPsePortGroupIndex OBJECT-TYPE SYNTAX INTEGER(1..2147483647) ACCESS not-accessible STATUS mandatory DESCRIPTION "This variable uniquely identifies the group containing the port to which a power Ethernet PSE is connected. Group means box in the stack, module in a rack and the value 1 MUST be used for non-modular devices. Furthermore, the same value MUST be used in this variable, pethMainPseGroupIndex, and pethNotificationControlGroupIndex to refer to a given box in a stack or module in the rack." ::= { pethPsePortEntry 1 } pethPsePortIndex OBJECT-TYPE SYNTAX INTEGER(1..2147483647) ACCESS not-accessible STATUS mandatory DESCRIPTION "This variable uniquely identifies the power Ethernet PSE port within group pethPsePortGroupIndex to which the power Ethernet PSE entry is connected." ::= { pethPsePortEntry 2 } pethPsePortAdminEnable OBJECT-TYPE SYNTAX TruthValue -- Rsyntax INTEGER { -- true(1), -- false(2) -- } ACCESS read-write STATUS mandatory DESCRIPTION "true (1) An interface which can provide the PSE functions. false(2) The interface will act as it would if it had no PSE function." REFERENCE "IEEE Std 802.3af Section 30.9.1.1.2 aPSEAdminState" ::= { pethPsePortEntry 3 } pethPsePortPowerPairsControlAbility OBJECT-TYPE SYNTAX TruthValue -- Rsyntax INTEGER { -- true(1), -- false(2) -- } ACCESS read-only STATUS mandatory DESCRIPTION "Describes the capability of controlling the power pairs functionality to switch pins for sourcing power. The value true indicate that the device has the capability to control the power pairs. When false the PSE Pinout Alternative used cannot be controlled through the PethPsePortAdminEnable attribute." REFERENCE "IEEE Std 802.3af Section 30.9.1.1.3 aPSEPowerPairsControlAbility" ::= { pethPsePortEntry 4 } pethPsePortPowerPairs OBJECT-TYPE SYNTAX INTEGER { signal(1), spare(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Describes or controls the pairs in use. If the value of pethPsePortPowerPairsControl is true, this object is writable. A value of signal(1) means that the signal pairs only are in use. A value of spare(2) means that the spare pairs only are in use." REFERENCE "IEEE Std 802.3af Section 30.9.1.1.4 aPSEPowerPairs" ::= { pethPsePortEntry 5 } pethPsePortDetectionStatus OBJECT-TYPE SYNTAX INTEGER { disabled(1), searching(2), deliveringPower(3), fault(4), test(5), otherFault(6) } ACCESS read-only STATUS mandatory DESCRIPTION "Describes the operational status of the port PD detection. A value of disabled(1)- indicates that the PSE State diagram is in the state DISABLED. A value of deliveringPower(3) - indicates that the PSE State diagram is in the state POWER_ON for a duration greater than tlim max (see IEEE Std 802.3af Table 33-5 tlim). A value of fault(4) - indicates that the PSE State diagram is in the state TEST_ERROR. A value of test(5) - indicates that the PSE State diagram is in the state TEST_MODE. A value of otherFault(6) - indicates that the PSE State diagram is in the state IDLE due to the variable error_conditions. A value of searching(2)- indicates the PSE State diagram is in a state other than those listed above." REFERENCE "IEEE Std 802.3af Section 30.9.1.1.5 aPSEPowerDetectionStatus" ::= { pethPsePortEntry 6 } pethPsePortPowerPriority OBJECT-TYPE SYNTAX INTEGER { critical(1), high(2), low(3) } ACCESS read-write STATUS mandatory DESCRIPTION "This object controls the priority of the port from the point of view of a power management algorithm. The priority that is set by this variable could be used by a control mechanism that prevents over current situations by disconnecting first ports with lower power priority. Ports that connect devices critical to the operation of the network - like the E911 telephones ports - should be set to higher priority." ::= { pethPsePortEntry 7 } pethPsePortMPSAbsentCounter OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This counter is incremented when the PSE state diagram transitions directly from the state POWER_ON to the state IDLE due to tmpdo_timer_done being asserted." REFERENCE "IEEE Std 802.3af Section 30.9.1.1.11 aPSEMPSAbsentCounter" ::= { pethPsePortEntry 8 } pethPsePortType OBJECT-TYPE SYNTAX SnmpAdminString -- Rsyntax OCTET STRING(SIZE(0..255)) ACCESS read-write STATUS mandatory DESCRIPTION "A manager will set the value of this variable to indicate the type of powered device that is connected to the port. The default value supplied by the agent if no value has ever been set should be a zero-length octet string." ::= { pethPsePortEntry 9 } pethPsePortPowerClassifications OBJECT-TYPE SYNTAX INTEGER { class0(1), class1(2), class2(3), class3(4), class4(5) } ACCESS read-only STATUS mandatory DESCRIPTION "Classification is a way to tag different terminals on the Power over LAN network according to their power consumption. Devices such as IP telephones, WLAN access points and others, will be classified according to their power requirements. The meaning of the classification labels is defined in the IEEE specification. This variable is valid only while a PD is being powered, that is, while the attribute pethPsePortDetectionStatus is reporting the enumeration deliveringPower." REFERENCE "IEEE Std 802.3af Section 30.9.1.1.6 aPSEPowerClassification" ::= { pethPsePortEntry 10 } pethPsePortInvalidSignatureCounter OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This counter is incremented when the PSE state diagram enters the state SIGNATURE_INVALID." REFERENCE "IEEE Std 802.3af Section 30.9.1.1.7 aPSEInvalidSignatureCounter" ::= { pethPsePortEntry 11 } pethPsePortPowerDeniedCounter OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This counter is incremented when the PSE state diagram enters the state POWER_DENIED." REFERENCE "IEEE Std 802.3af Section 30.9.1.1.8 aPSEPowerDeniedCounter" ::= { pethPsePortEntry 12 } pethPsePortOverLoadCounter OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This counter is incremented when the PSE state diagram enters the state ERROR_DELAY_OVER." REFERENCE "IEEE Std 802.3af Section 30.9.1.1.9 aPSEOverLoadCounter" ::= { pethPsePortEntry 13 } pethPsePortShortCounter OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This counter is incremented when the PSE state diagram enters the state ERROR_DELAY_SHORT." REFERENCE "IEEE Std 802.3af Section 30.9.1.1.10 aPSEShortCounter" ::= { pethPsePortEntry 14 } pethMainPseTable OBJECT-TYPE SYNTAX SEQUENCE OF PethMainPseEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of objects that display and control attributes of the main power source in a PSE device. Ethernet switches are one example of boxes that would support these objects. Values of all read-write objects in this table are persistent at restart/reboot." ::= { pethMainPseObjects 1 } pethMainPseEntry OBJECT-TYPE SYNTAX PethMainPseEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A set of objects that display and control the Main power of a PSE. " INDEX { pethMainPseGroupIndex } ::= { pethMainPseTable 1 } PethMainPseEntry ::= SEQUENCE { pethMainPseGroupIndex INTEGER, pethMainPsePower Gauge, pethMainPseOperStatus INTEGER, pethMainPseConsumptionPower Gauge, pethMainPseUsageThreshold INTEGER } pethMainPseGroupIndex OBJECT-TYPE SYNTAX INTEGER(1..2147483647) ACCESS not-accessible STATUS mandatory DESCRIPTION "This variable uniquely identifies the group to which power Ethernet PSE is connected. Group means (box in the stack, module in a rack) and the value 1 MUST be used for non-modular devices. Furthermore, the same value MUST be used in this variable, pethPsePortGroupIndex, and pethNotificationControlGroupIndex to refer to a given box in a stack or module in a rack." ::= { pethMainPseEntry 1 } pethMainPsePower OBJECT-TYPE SYNTAX Gauge(1..65535) -- Units -- Watts ACCESS read-only STATUS mandatory DESCRIPTION "The nominal power of the PSE expressed in Watts." ::= { pethMainPseEntry 2 } pethMainPseOperStatus OBJECT-TYPE SYNTAX INTEGER { on(1), off(2), faulty(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The operational status of the main PSE." ::= { pethMainPseEntry 3 } pethMainPseConsumptionPower OBJECT-TYPE SYNTAX Gauge -- Units -- Watts ACCESS read-only STATUS mandatory DESCRIPTION "Measured usage power expressed in Watts." ::= { pethMainPseEntry 4 } pethMainPseUsageThreshold OBJECT-TYPE SYNTAX INTEGER(1..99) -- Units -- % ACCESS read-write STATUS mandatory DESCRIPTION "The usage threshold expressed in percents for comparing the measured power and initiating an alarm if the threshold is exceeded." ::= { pethMainPseEntry 5 } pethNotificationControlTable OBJECT-TYPE SYNTAX SEQUENCE OF PethNotificationControlEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of objects that display and control the Notification on a PSE device. Values of all read-write objects in this table are persistent at restart/reboot." ::= { pethNotificationControl 1 } pethNotificationControlEntry OBJECT-TYPE SYNTAX PethNotificationControlEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A set of objects that control the Notification events." INDEX { pethNotificationControlGroupIndex } ::= { pethNotificationControlTable 1 } PethNotificationControlEntry ::= SEQUENCE { pethNotificationControlGroupIndex INTEGER, pethNotificationControlEnable TruthValue } pethNotificationControlGroupIndex OBJECT-TYPE SYNTAX INTEGER(1..2147483647) ACCESS not-accessible STATUS mandatory DESCRIPTION "This variable uniquely identifies the group. Group means box in the stack, module in a rack and the value 1 MUST be used for non-modular devices. Furthermore, the same value MUST be used in this variable, pethPsePortGroupIndex, and pethMainPseGroupIndex to refer to a given box in a stack or module in a rack. " ::= { pethNotificationControlEntry 1 } pethNotificationControlEnable OBJECT-TYPE SYNTAX TruthValue -- Rsyntax INTEGER { -- true(1), -- false(2) -- } ACCESS read-write STATUS mandatory DESCRIPTION "This object controls, on a per-group basis, whether or not notifications from the agent are enabled. The value true(1) means that notifications are enabled; the value false(2) means that they are not." ::= { pethNotificationControlEntry 2 } pethPsePortOnOffNotification TRAP-TYPE -- Reverse mappable trap ENTERPRISE powerEthernetMIB VARIABLES { pethPsePortDetectionStatus } -- Status -- mandatory DESCRIPTION " This Notification indicates if Pse Port is delivering or not power to the PD. This Notification SHOULD be sent on every status change except in the searching mode. At least 500 msec must elapse between notifications being emitted by the same object instance." ::= 1 pethMainPowerUsageOnNotification TRAP-TYPE -- Reverse mappable trap ENTERPRISE powerEthernetMIB VARIABLES { pethMainPseConsumptionPower } -- Status -- mandatory DESCRIPTION " This Notification indicate PSE Threshold usage indication is on, the usage power is above the threshold. At least 500 msec must elapse between notifications being emitted by the same object instance." ::= 2 pethMainPowerUsageOffNotification TRAP-TYPE -- Reverse mappable trap ENTERPRISE powerEthernetMIB VARIABLES { pethMainPseConsumptionPower } -- Status -- mandatory DESCRIPTION " This Notification indicates PSE Threshold usage indication off, the usage power is below the threshold. At least 500 msec must elapse between notifications being emitted by the same object instance." ::= 3 pethPsePortGroup OBJECT IDENTIFIER ::= { pethGroups 1 } -- OBJECT-GROUP -- Status -- mandatory -- Descr -- PSE Port objects. -- objects -- pethPsePortAdminEnable, pethPsePortPowerPairsControlAbility, -- pethPsePortPowerPairs, pethPsePortDetectionStatus, -- pethPsePortPowerPriority, pethPsePortMPSAbsentCounter, -- pethPsePortInvalidSignatureCounter, -- pethPsePortPowerDeniedCounter, pethPsePortOverLoadCounter, -- pethPsePortShortCounter, pethPsePortType, -- pethPsePortPowerClassifications pethMainPseGroup OBJECT IDENTIFIER ::= { pethGroups 2 } -- OBJECT-GROUP -- Status -- mandatory -- Descr -- Main PSE Objects. -- objects -- pethMainPsePower, pethMainPseOperStatus, -- pethMainPseConsumptionPower, pethMainPseUsageThreshold pethNotificationControlGroup OBJECT IDENTIFIER ::= { pethGroups 3 } -- OBJECT-GROUP -- Status -- mandatory -- Descr -- Notification Control Objects. -- objects -- pethNotificationControlEnable pethPsePortNotificationGroup OBJECT IDENTIFIER ::= { pethGroups 4 } -- NOTIFICATION-GROUP -- Status -- mandatory -- Descr -- Pse Port Notifications. -- notifications -- pethPsePortOnOffNotification pethMainPowerNotificationGroup OBJECT IDENTIFIER ::= { pethGroups 5 } -- NOTIFICATION-GROUP -- Status -- mandatory -- Descr -- Main PSE Notifications. -- notifications -- pethMainPowerUsageOnNotification, -- pethMainPowerUsageOffNotification pethCompliance OBJECT IDENTIFIER ::= { pethCompliances 1 } -- MODULE-COMPLIANCE -- Status -- mandatory -- Descr -- Describes the requirements for conformance to the -- Power Ethernet MIB. -- Module -- >>current<< -- MandGroup -- pethPsePortGroup -- MandGroup -- pethPsePortNotificationGroup -- MandGroup -- pethNotificationControlGroup -- OptGroup -- pethMainPseGroup -- OptGroup -- pethMainPowerNotificationGroup END