{ "$schema": "../../data/schema/measurement.schema.json", "schema_version": "1.0.0", "language": "en", "creator": { "name": "Michelangelo Canonico", "role": "Creator and lead measurer", "affiliation": "Direct Sound Records" }, "publisher": { "name": "Direct Sound Records", "url": "https://directsoundrecords.com/", "location_label": "London–Rome" }, "software": { "name": "Groove Scope", "report_generator_label": "Groove Scope Reference", "application_version": "not_recorded", "analysis_method_version": "not_recorded", "platform": "not_recorded", "developer": "Michelangelo Canonico / Direct Sound Records" }, "related_applications": [ { "name": "Resonance Lab", "relationship": "Companion application for tonearm and cartridge resonance planning", "url": "https://directsoundrecords.com/resonance-lab/" } ], "measurement_type": "1 kHz Reference Check", "measurement_scope": [ "playback speed", "rotational stability", "DIN-shaped wow and flutter", "channel balance", "electrical crosstalk", "distortion diagnostics", "harmonic profile", "rotation fingerprints" ], "license": "CC-BY-4.0", "measurement_id": "GS-2026-0006", "record_version": "0.9.0", "publication_status": "draft", "title": "Micro Seiki RX-5000 / SME V / Transfiguration Orpheus — 1 kHz Playback Check", "source_report_title": "Transfiguration Orpheus", "slug": "gs-2026-0006-transfiguration-orpheus-micro-seiki-rx-5000-sme-v-1-khz-reference-check", "measurement_datetime_local": "2026-09-26T16:24:00", "measurement_timezone": "not_recorded", "date_published": "2026-10-02", "sample_id": "not_recorded", "setup": { "turntable": "Micro Seiki RX-5000", "tonearm": "SME V", "cartridge": "Transfiguration Orpheus", "stylus": "not_recorded", "cartridge_hours": "not_recorded", "vertical_tracking_force_g": "not_recorded", "anti_skate_setting": "not_recorded", "alignment_geometry": "not_recorded", "azimuth_setting": "not_recorded", "vta_or_sra_setting": "not_recorded", "phono_stage": "not_recorded", "phono_gain_db": "not_recorded", "cartridge_loading": "not_recorded", "test_record": "not_recorded", "test_record_track": "not_recorded", "test_record_condition": "not_recorded", "nominal_test_tone_hz": 1000, "audio_interface_reported_label": "not_recorded", "audio_interface_full_model": "EVO4", "interface_gain_settings": "not_recorded", "sample_rate_hz": "not_recorded", "bit_depth": "not_recorded", "capture_device": "not_recorded", "channel_routing": "not_recorded", "measurement_location": "not_recorded" }, "results": { "playback_rpm": { "value": 33.51, "classification": "primary", "condition": "under_stylus_load" }, "playback_speed_error_percent": { "value": 0.52, "classification": "primary", "direction": "fast" }, "settled_rpm": { "minimum": 33.42, "maximum": 33.58, "span": 0.16, "classification": "primary" }, "din_shaped_wow_flutter_percent": { "value": 0.031, "classification": "primary" }, "raw_speed_variation_percent": { "rms_plus_minus": 0.136, "two_sigma_plus_minus": 0.271, "classification": "unweighted_diagnostic" }, "raw_wow_flutter_percent": { "wow_rms": 0.129, "flutter_rms": 0.039, "classification": "unweighted_diagnostic" }, "channel_balance_db": { "value": -0.35, "classification": "diagnostic_only" }, "crosstalk_1khz_db": { "average_separation": 19.5, "left_to_right": -19.1, "right_to_left": -19.8, "directional_difference": 0.64, "classification": "supporting" }, "thd_percent": { "left": 0.87, "right": 1.18, "left_minus_right_percentage_points": -0.31, "classification": "diagnostic" }, "harmonic_profile_db": { "h2": { "left": -41.3, "right": -38.6 }, "h3": { "left": -60.1, "right": -61.7 }, "h4": { "left": -75.2, "right": -77.1 }, "h5": { "left": -73.3, "right": -73.9 }, "classification": "diagnostic" }, "harmonic_difference_summary_db": { "h2_right_higher": 2.7, "h3_left_higher": 1.6, "classification": "source_report_summary" }, "harmonic_reliability": { "classification": "steady_during_recording", "quality_note": "Steady during recording. Suitable for setup guidance." } }, "interpretation": { "summary": "The RX-5000 averaged 33.51 RPM, or +0.52%, while DIN-shaped wow and flutter measured 0.031%. That combination separates a notably high mean-speed reading from low measured rotational variation in this capture; it does not identify the cause. Average separation was 19.5 dB, and harmonic levels were reported steady during recording.", "recommendation": "Repeat the same capture with documented test-record track and setup settings to assess whether the speed and channel patterns recur.", "repeat_required": false }, "provenance": { "source_type": "Groove Scope generated PDF report", "source_file": "report.pdf", "data_entry_method": "Values transcribed verbatim from the original PDF report; rounded differences are preserved rather than recalculated.", "raw_audio_published": false, "raw_audio_note": "No raw test-record audio is included.", "sample_ownership": "not_recorded", "setup_metadata_source": "The source PDF identifies the cartridge as Transfiguration Orpheus, but does not name the turntable, tonearm or input. The measurer supplied the Micro Seiki RX-5000, SME V and EVO4 identities; the supplied photograph visibly carries an RX-5000 badge.", "known_limitations": [ "The source report does not identify the turntable, tonearm or input; those component identities were supplied by the measurer.", "Tracking force, anti-skate, alignment, phono stage, loading, test-record identity and track, gain, capture format, software versions, timezone, sample ownership and repeat count were not supplied.", "One supplied report; stability within a recording does not establish repeatability across sessions.", "THD and harmonic differences retain source-report precision and may differ from subtraction of rounded channel values." ], "fingerprint_channel_assignment": "Left/right assignments follow the supplied screenshot pair order. The supplied plots do not contain visible channel labels.", "photo_treatment": "AI-assisted cosmetic editorial hero removes the partial person and background distractions. Original HEIC preserved; graph screenshots are unretouched." }, "files": { "human_readable_record": "README.md", "source_report": "report.pdf", "checksums": "checksums.sha256", "source_hero": "assets/source/hero-original.heic", "rotation_fingerprints": [ "assets/source/speed-deviation-left.png", "assets/source/speed-deviation-right.png", "assets/source/level-modulation-left.png", "assets/source/level-modulation-right.png", "assets/source/opposite-channel-leakage-left.png", "assets/source/opposite-channel-leakage-right.png", "assets/source/harmonic-distortion-left.png", "assets/source/harmonic-distortion-right.png" ], "retouched_hero": "assets/hero-retouched.png", "image_edit_prompt": "assets/image-edit-prompt.txt" }, "keywords": [ "Groove Scope", "Direct Sound Records", "Michelangelo Canonico", "Micro Seiki RX-5000", "SME V", "Transfiguration Orpheus", "EVO4", "vinyl measurement", "rotation fingerprint", "wow and flutter", "cartridge crosstalk" ] }