[z_calibration] nozzle_xy_position: 95, 257.5 # A X, Y coordinate (e.g. 100,100) of the nozzle, clicking on the Z endstop. #switch_xy_position: 93, 228.75 switch_xy_position: 91, 230 # x_offset: -2 # y_offset: 28.75 # A X, Y coordinate (e.g. 100,100) of the probe's switch body, clicking on # the Z endstop. bed_xy_position: 110, 110 # a X, Y coordinate (e.g. 100,100) where the print surface (e.g. the center # point) is probed. These coordinates will be adapted by the # probe's X and Y offsets. The default is the relative_reference_index # of the configured bed_mesh, if configured. It's possible to change the relative # reference index at runtime or use the GCode argument BED_POSITION of CALIBRATE_Z. switch_offset: 0.285 offset_margins:-2.75, -2.35 # The trigger point offset of the used mag-probe switch. # Larger values will position the nozzle closer to the bed. # This needs to be find out manually. More on this later # in this section.. max_deviation: 2.75 # The maximum allowed deviation of the calculated offset. # If the offset exceeds this value, it will stop! # The default is 1.0 mm. samples: 3 # The number of times to probe each point. The probed z-values # will be averaged. The default is from the probe's configuration. samples_tolerance: 0.05 # The maximum Z distance (in mm) that a sample may differ from other # samples. The default is from the probe's configuration. samples_tolerance_retries: 5 # The number of times to retry if a sample is found that exceeds # samples_tolerance. The default is from the probe's configuration. samples_result: median # The calculation method when sampling more than once - either # "median" or "average". The default is from the probe's configuration. clearance: 20 # The distance in mm to move up before moving to the next # position. The default is two times the z_offset from the probe's # configuration. # position_min: 0 # Minimum valid distance (in mm) used for probing move. The # default is from the Z rail configuration. speed: 50 # The moving speed in X and Y. The default is 50 mm/s. # lift_speed: default from "probe:lift_speed" section # Speed (in mm/s) of the Z axis when lifting the probe between # samples and clearance moves. The default is from the probe's # configuration. # probing_speed: default from "stepper_z:homing_speed" section. # The fast probing speed (in mm/s) used, when probing_first_fast # is activated. The default is from the Z rail configuration. # probing_second_speed: default from "stepper_z:second_homing_speed" section. # The slower speed (in mm/s) for probing the recorded samples. # The default is second_homing_speed of the Z rail configuration. # probing_retract_dist: default from "stepper_z:homing_retract_dist" section. # Distance to retract (in mm) before probing the next sample. # The default is homing_retract_dist from the Z rail configuration. probing_first_fast: false # If true, the first probing is done faster by the probing speed. # This is to get faster down and the result is not recorded as a # probing sample. The default is false. start_gcode: Attach_Probe # A list of G-Code commands to execute prior to each calibration command. # See docs/Command_Templates.md for G-Code format. This can be used to # attach the probe. #before_switch_gcode: # A list of G-Code commands to execute prior to each probing on the # mag-probe. See docs/Command_Templates.md for G-Code format. This can be # used to attach the probe after probing on the nozzle and before probing # on the mag-probe. end_gcode: Dock_Probe # A list of G-Code commands to execute after each calibration command. # See docs/Command_Templates.md for G-Code format. This can be used to # detach the probe afterwards.