- id: HeatpumpLegionellaStartBoilerSetpoint alias: Set boiler setpoint to 56 when starting legionella run trigger: - trigger: state entity_id: - sensor.ecodan_heatpump_operation_mode to: Legionella Prevention conditions: - condition: numeric_state entity_id: sensor.ecodan_heatpump_dhw_setpoint_value below: 56 action: - action: climate.set_temperature data: entity_id: climate.ecodan_heatpump_dhw_climate temperature: 56 - id: HeatpumpLegionellaFinishBoilerSetpoint alias: Set boiler setpoint to 47 when legionella run is completed trigger: - trigger: state entity_id: - sensor.ecodan_heatpump_operation_mode from: Legionella Prevention conditions: - condition: numeric_state entity_id: sensor.ecodan_heatpump_dhw_setpoint_value above: 47 action: - action: climate.set_temperature data: entity_id: climate.ecodan_heatpump_dhw_climate temperature: 47