1 00:00:00,000 --> 00:00:04,950 Lesson 6: model tools: geometry bar, Check, Segmentation, Warnings 2 00:00:05,000 --> 00:00:21,120 YA-NEC course, lesson 6: the model tools. We start from an example: the 20 m dipole at 10 m over average ground. 3 00:00:21,170 --> 00:00:28,475 74.2 + j10.7 ohm, 7.11 dBi at 29.5 degrees. 4 00:00:28,525 --> 00:00:35,795 The Geometry bar works on the whole antenna or on the selected wires. 'Move': Z = 5 m. 5 00:00:35,845 --> 00:00:45,928 The preview shows the antenna in its new place, and the box lists what changes in the wire table. Units are accepted too: 10cm, 6in, 2ft. 6 00:00:45,978 --> 00:00:53,070 'Apply move'. 7 00:00:53,120 --> 00:01:07,763 Now at 15 m: 74.2 + j30.1 ohm, 7.52 dBi, and the main lobe drops from 29.5 to 19.6 degrees. Sources and loads follow the wires by themselves. 8 00:01:07,813 --> 00:01:14,430 Quick commands: 'horizontal <-> vertical' turns the dipole upright around its centre. 9 00:01:14,480 --> 00:01:26,477 Vertical dipole, bottom end at 9.8 m: 76.5 + j22.7 ohm, 2.01 dBi. Average ground eats much more of a vertical antenna. 10 00:01:26,527 --> 00:01:34,607 'Undo' twice: back to the starting dipole. Every geometry command can be undone and redone. 11 00:01:34,657 --> 00:01:38,937 74.2 + j10.7 ohm again. 12 00:01:38,987 --> 00:01:53,111 Now a classic mistake: only 3 segments on the 10.4 m wire. 13 00:01:53,161 --> 00:02:00,073 The result still looks reasonable - 75.4 + j7.3 ohm - and that is exactly the danger. 14 00:02:00,123 --> 00:02:06,960 The Warnings tab says why. 15 00:02:07,010 --> 00:02:18,032 Segments longer than lambda/10 (2.11 m): 3.47 m. The NEC-2 guide advises against it; EZNEC flags it as 'segment length too long'. 16 00:02:18,082 --> 00:02:29,133 'Check...' runs the data checks that need no calculation. 17 00:02:29,183 --> 00:02:40,012 43 checks, all fine: the data are valid. Segment length is the job of the next tool. 18 00:02:40,062 --> 00:02:49,346 'Segmentation...': segment length, segment/radius ratio, equal segments around sources and lines (rules from EZNEC and ARRL). 19 00:02:49,396 --> 00:02:59,240 Wire 1: segment too long, 3.47 m against a minimum of 2.09 m. Target level: prudent, lambda/20. 20 00:02:59,290 --> 00:03:05,305 'Preview' computes before and after without touching the model. 21 00:03:05,355 --> 00:03:10,372 From 3 to 11 segments, odd so the source stays in the centre. 22 00:03:10,422 --> 00:03:17,438 'Apply and recalculate'. 23 00:03:17,488 --> 00:03:25,438 Fixed: no warnings left. With a long model, this window can also open by itself before every calculation. 24 00:03:25,488 --> 00:03:36,131 Move, rotate, scale, undo, check, segment: the model stays clean. Next lesson: simple HF beams from the calculators. 73 de IC8TEM