/* groovylint-disable CompileStatic, ConsecutiveStringConcatenation, DuplicateMapLiteral, ImplementationAsType, MethodParameterTypeRequired, MethodReturnTypeRequired, MethodSize, NoDef, NoDouble, SpaceAfterClosingBrace, UnnecessaryObjectReferences, UnnecessaryPackageReference, UnusedImport, UnusedPrivateMethod, VariableName, VariableTypeRequired */
/**
* Tuya Temperature Humidity Illuminance LCD Display with a Clock
*
* Licensed under the Apache License, Version 2.0 (the "License"); you may not use this file except
* in compliance with the License. You may obtain a copy of the License at:
*
* http://www.apache.org/licenses/LICENSE-2.0
*
* Unless required by applicable law or agreed to in writing, software distributed under the License is distributed
* on an "AS IS" BASIS, WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. See the License
* for the specific language governing permissions and limitations under the License.
*
* ver. 1.0.0 2022-01-02 kkossev - Inital test version
* ver. 1.0.1 2022-02-05 kkossev - Added Zemismart ZXZTH fingerprint; added _TZE200_locansqn; Fahrenheit scale + rounding; temperatureScaleParameter; temperatureSensitivity; minTempAlarm; maxTempAlarm
* ver. 1.0.2 2022-02-06 kkossev - Tuya commands refactoring; TS0222 T/H poll on illuminance change (EP2); modelGroupPreference bug fix; dyncamic parameters
* ver. 1.0.3 2022-02-13 kkossev - _TZE200_c7emyjom fingerprint added;
* ver. 1.0.4 2022-02-20 kkossev - Celsius/Fahrenheit correction for TS0601_Tuya devices
* ver. 1.0.5 2022-04-25 kkossev - added TS0601_AUBESS (illuminance only); ModelGroup is shown in State Variables
* ver. 1.0.6 2022-05-09 kkossev - new model 'TS0201_LCZ030' (_TZ3000_qaaysllp)
* ver. 1.0.7 2022-06-09 kkossev - new model 'TS0601_Contact'(_TZE200_pay2byax); illuminance unit changed to 'lx; Bug fix - all settings were reset back in to the defaults on hub reboot
* ver. 1.0.8 2022-08-13 kkossev - _TZE200_pay2byax bug fixes; '_TZE200_locansqn' (TS0601_Haozee) bug fixes; removed degrees symbol from the logs; removed temperatureScaleParameter'preference (use HE scale setting); decimal/number bug fixes;
* added temperature and humidity offesets; configured parameters (including C/F HE scale) are sent to the device when paired again to HE; added Minimum time between temperature and humidity reports;
* ver. 1.0.9 2022-10-02 kkossev - configure _TZ2000_a476raq2 reporting time; added TS0601 _TZE200_bjawzodf; code cleanup
* ver. 1.0.10 2022-10-11 kkossev - '_TZ3000_itnrsufe' reporting configuration bug fix?; reporting configuration result Info log; added Sonoff SNZB-02 fingerprint; reportingConfguration is sent on pairing to HE;
* ver. 1.0.11 2022-10-31 kkossev - added _TZE200_whkgqxse; fingerprint correction; _TZ3000_bguser20 _TZ3000_fllyghyj _TZ3000_yd2e749y _TZ3000_6uzkisv2
* ver. 1.1.0 2022-12-18 kkossev - added _info_ attribute; delayed reporting configuration when the sleepy device wakes up; excluded TS0201 model devices in the delayed configuration; _TZE200_locansqn fingerprint correction and max reporting periods formula correction
* added TS0601_Soil _TZE200_myd45weu ; added _TZE200_znbl8dj5 _TZE200_a8sdabtg _TZE200_qoy0ekbd
* ver. 1.1.1 2023-01-14 kkossev - added _TZ3000_ywagc4rj TS0201_TH; bug fix: negative temperatures not calculated correctly;
* ver. 1.2.0 2023-01-15 kkossev - parsing multiple DP received in one command;
* ver. 1.2.1 2023-01-15 kkossev - _TZE200_locansqn fixes;_TZ3000_bguser20 correct model;
* ver. 1.3.0 2023-02-02 kkossev - healthStatus; added capability 'Health Check'
* ver. 1.3.1 2023-02-10 kkossev - added RH3052 TUYATEC-gqhxixyk
* ver. 1.3.2 2023-03-04 kkossev - added TS0601 _TZE200_zl1kmjqx _TZE200_qyflbnbj, added TS0201 _TZ3000_dowj6gyi and _TZ3000_8ybe88nf
* ver. 1.3.3 2023-04-23 kkossev - _TZE200_znbl8dj5 inClusters correction; ignored invalid humidity values; implemented ping() and rtt (round-trip-time) attribute;
* ver. 1.3.4 2023-04-24 kkossev - send rtt 'timeout' if ping() fails; added resetStats command; added individual stat.stats counters for T/H/I/battery; configuration possible loop bug fix;
* ver. 1.3.5 2023-05-28 kkossev - sendRttEvent exception fixed; added _TZE200_cirvgep4 in TS0601_Tuya group; fingerprint correction; battery reports are capped to 100% and not ignored;
* ver. 1.3.6 2023-06-10 kkossev - added _TZE200_yjjdcqsq to TS0601_Tuya group;
* ver. 1.3.7 2023-08-02 vpjuslin -Yet another name for Tuya soil sensor: _TZE200_ga1maeof
* ver. 1.3.8 2023-08-17 kkossev - added OWON THS317-ET for tests; added TS0201 _TZ3000_rdhukkmi; added TS0222 _TYZB01_ftdkanlj
* ver. 1.3.9 2023-09-29 kkossev - added Sonoff SNZB-02P; added TS0201 _TZ3210_ncw88jfq; moved _TZE200_yjjdcqsq and _TZE200_cirvgep4 to a new group 'TS0601_Tuya_2'; added _TZE204_upagmta9, added battery state 'low', 'medium', 'high'
* ver. 1.3.10 2023-11-28 kkossev - added TS0222 _TYZB01_fi5yftwv; added temperature scale (C/F) and temperature sensitivity setting for TS0601_Tuya_2 group;
* ver. 1.4.0 2023-11-28 kkossev - bug fix - healthStatus periodic job was not started; _TZ3000_qaaysllp illuminance dp added;
* ver. 1.5.0 2024-01-27 kkossev - Groovy lint; added TS0601 _TZE200_vvmbj46n to TS0601_Tuya_2 group; _TZE200_qyflbnbj fingerprint correction; added TS0201 _TZ3000_utwgoauk
* ver. 1.5.1 2024-02-13 kkossev - bugfix: battery reporting period for non-Tuya devices.
* ver. 1.5.2 2024-05-14 kkossev - added _TZE204_upagmta9 and _TZE200_upagmta9 to TS0601_Tuya_2 group; healthStatus initialized as 'unknown';
* ver. 1.6.0 2024-05-19 kkossev - added the correct NOUS TS0601 _TZE200_nnrfa68v fingerprint to group 'TS0601_Tuya'; all Current States and Preferences are cleared on initialize command;
* ver. 1.6.1 2024-06-10 kkossev - added ThirdReality 3RTHS0224Z and 3RTHS24BZ
* ver. 1.6.2 2024-06-26 kkossev - added TS000F _TZ3218_7fiyo3kv in DS18B20 group (temperature only); added Tuya cluster command '06' processing; added description in the debug logs
* ver. 1.6.3 2024-07-16 kkossev - added TS0601 _TZE204_yjjdcqsq to TS0601_Tuya_2 group;
* ver. 1.6.4 2024-07-23 kkossev - added Tuya Smart Soil Tester _TZE284_aao3yzhs into 'TS0601_Soil_II'
* ver. 1.6.5 2024-08-09 kkossev - bugfix: TS0201 _TZ3000_dowj6gyi moved back to TS0201 group;
* ver. 1.6.6 2024-08-14 kkossev - (dev.branch) added TS0601 _TZE204_myd45weu; added TS0601 _TZE204_qyflbnbj
*
* TODO: queryOnDeviceAnnounce for TS0601_Tuya_2 group
* TODO: TS0601 _TZE200_vvmbj46n - preferences changes are not accepted by the device!; add temperature and humidity max reporting interval settings for TS0601_Tuya_2 group;
* TODO: add TS0601 _TZE200_khx7nnka in a new TUYA_LIGHT device profile : https://community.hubitat.com/t/simple-smart-light-sensor/110341/16?u=kkossev @Pradeep
* TODO: _TZ3000_qaaysllp frequent illuminance reports - check configuration; add minimum time between lux reports parameter!
* TODO: TS0201 - bindings are sent, even if nothing to configure?
* TODO: add Batteryreporting time configuration (like in the TS004F driver)
*/
@Field static final String VERSION = '1.6.6'
@Field static final String TIME_STAMP = '2024/08/14 12:48 PM'
import groovy.json.*
import groovy.transform.Field
import hubitat.zigbee.zcl.DataType
import hubitat.device.HubAction
import hubitat.device.Protocol
@Field static final Boolean _DEBUG = false
metadata {
definition(name: 'Tuya Temperature Humidity Illuminance LCD Display with a Clock', namespace: 'kkossev', author: 'Krassimir Kossev', importUrl: 'https://raw.githubusercontent.com/kkossev/Hubitat/development/Drivers/Tuya%20Temperature%20Humidity%20Illuminance%20LCD%20Display%20with%20a%20Clock/Tuya_Temperature_Humidity_Illuminance_LCD_Display_with_a_Clock.groovy', singleThreaded: true ) {
capability 'Refresh'
capability 'Sensor'
capability 'Battery'
capability 'TemperatureMeasurement'
capability 'RelativeHumidityMeasurement'
capability 'IlluminanceMeasurement'
//capability "ContactSensor" // uncomment for _TZE200_pay2byax contact w/ illuminance sensor
//capability "MotionSensor" // uncomment for SiHAS multi sensor
capability 'Health Check'
if (_DEBUG == true) {
command 'zTest', [
[name:'dpCommand', type: 'STRING', description: 'Tuya DP Command', constraints: ['STRING']],
[name:'dpValue', type: 'STRING', description: 'Tuya DP value', constraints: ['STRING']],
[name:'dpType', type: 'ENUM', constraints: ['DP_TYPE_VALUE', 'DP_TYPE_BOOL', 'DP_TYPE_ENUM'], description: 'DP data type']
]
command 'test', [[name:'test', type: 'STRING', description: 'test', constraints: ['STRING']]]
}
command 'resetStats', [[name: 'Reset statistics' ]]
command 'initialize', [[name: 'Manually initialize the device after switching drivers. \n\r ***** Will load device default values! *****' ]]
attribute '_info', 'string' // when defined as attribute, will be shown on top of the 'Current States' list ...
attribute 'healthStatus', 'enum', ['unknown', 'offline', 'online']
attribute 'rtt', 'number'
fingerprint profileId:'0104', endpointId:'01', inClusters:'0004,0005,EF00,0000', outClusters:'0019,000A', model:'TS0601', manufacturer:'_TZE200_lve3dvpy', deviceJoinName: 'Tuya Temperature Humidity Illuminance LCD Display with a Clock'
fingerprint profileId:'0104', endpointId:'01', inClusters:'0004,0005,EF00,0000', outClusters:'0019,000A', model:'TS0601', manufacturer:'_TZE200_c7emyjom', deviceJoinName: 'Tuya Temperature Humidity Illuminance LCD Display with a Clock'
fingerprint profileId:'0104', endpointId:'01', inClusters:'0004,0005,EF00,0000', outClusters:'0019,000A', model:'TS0601', manufacturer:'_TZE200_locansqn', deviceJoinName: 'Haozee Temperature Humidity Illuminance LCD Display with a Clock' // https://de.aliexpress.com/item/1005003634353180.html
fingerprint profileId:'0104', endpointId:'01', inClusters:'0000,0004,0005,EF00', outClusters:'0019,000A', model:'TS0601', manufacturer:'_TZE200_bq5c8xfe', deviceJoinName: 'Haozee Temperature Humidity Illuminance LCD Display with a Clock'
fingerprint profileId:'0104', endpointId:'01', inClusters:'0004,0005,EF00,0000', outClusters:'0019,000A', model:'TS0601', manufacturer:'_TZE200_nnrfa68v', deviceJoinName: 'NOUS Temperature Humidity Illuminance LCD Display with a Clock' // https://community.hubitat.com/t/nous-humidity-and-temp-sensor/137764?u=kkossev
fingerprint profileId:'0104', endpointId:'01', inClusters:'0000,0001,0402,0405', outClusters:'0019', model:'TS0201', manufacturer:'_TZ2000_hjsgdkfl', deviceJoinName: 'AVATTO S-H02'
fingerprint profileId:'0104', endpointId:'01', inClusters:'0000,0001,0402,0405', outClusters:'0019', model:'TS0201', manufacturer:'_TZ2000_a476raq2', deviceJoinName: 'Tuya Temperature Humidity LCD display'
fingerprint profileId:'0104', endpointId:'01', inClusters:'0000,0001,0400,E002', outClusters:'0019,000A', model:'TS0201', manufacturer:'_TZ3000_qaaysllp', deviceJoinName: 'NAS-TH02B LCZ030 T/H/I/LCD' // Neo Coolcam ? // NOT TESTED!
fingerprint profileId:'0104', endpointId:'01', inClusters:'0000,0001,0400', outClusters:'0019,000A', model:'TS0222', manufacturer:'_TYZB01_kvwjujy9', deviceJoinName: 'MOES ZSS-ZK-THL'
fingerprint profileId:'0104', endpointId:'01', inClusters:'0000,0001,0400', outClusters:'0019,000A', model:'TS0222', manufacturer:'_TYZB01_ftdkanlj', deviceJoinName: 'MOES ZSS-ZK-THL'
fingerprint profileId:'0104', endpointId:'01', inClusters:'0000,0400,0001,0500', outClusters:'0019,000A', model:'TS0222', manufacturer:'_TYZB01_4mdqxxnn', deviceJoinName: 'Tuya Illuminance Sensor TS0222_2'
fingerprint profileId:'0104', endpointId:'01', inClusters:'0000,0400,0001,0500', outClusters:'0019,000A', model:'TS0222', manufacturer:'_TZ3000_lfa05ajd', deviceJoinName: 'Zemismart ZXZTH'
fingerprint profileId:'0104', endpointId:'01', inClusters:'0000,0004,0005,EF00', outClusters:'0019,000A', model:'TS0601', manufacturer:'_TZE200_pisltm67', deviceJoinName: 'AUBESS Light Sensor S-LUX-ZB'
fingerprint profileId:'0104', endpointId:'01', inClusters:'0000,0004,0005,EF00', outClusters:'0019,000A', model:'TS0601', manufacturer:'_TYST11_pisltm67', deviceJoinName: 'AUBESS Light Sensor S-LUX-ZB'
fingerprint profileId:'0104', endpointId:'01', inClusters:'0001,0500,0000', outClusters:'0019,000A', model:'TS0601', manufacturer:'_TZE200_pay2byax', deviceJoinName: 'Tuya Contact and Illuminance Sensor'
fingerprint profileId:'0104', endpointId:'01', inClusters:'0001,0003,0402,0405,E002,0000', outClusters:'0003,0019,000A', model:'TS0201', manufacturer:'_TZ3000_itnrsufe', deviceJoinName: 'Tuya temperature and humidity sensor RCTW1Z'
fingerprint profileId:'0104', endpointId:'01', inClusters:'0001,0003,0402,0405,E002,0000', outClusters:'0003,0019,000A', model:'TS0201', manufacturer:'_TZ3000_ywagc4rj', deviceJoinName: 'Tuya temperature and humidity sensor' // https://community.hubitat.com/t/release-tuya-temperature-humidity-illuminance-lcd-display-with-a-clock/88093/211?u=kkossev
fingerprint profileId:'0104', endpointId:'01', inClusters:'0001,0402,0405,EF00,0000', outClusters:'0019,000A', model:'TS0201', manufacturer:'_TZ3210_ncw88jfq', deviceJoinName: 'Tuya temperature and humidity sensor' // https://community.hubitat.com/t/release-tuya-temperature-humidity-illuminance-lcd-display-with-a-clock/88093/211?u=kkossev
fingerprint profileId:'0104', endpointId:'01', inClusters:'0000,0001,0004,0005,0402,0405,EF00', outClusters:'0019,000A', model:'TS0601', manufacturer:'_TZE200_bjawzodf', deviceJoinName: 'Tuya like Temperature Humidity LCD Display' // https://de.aliexpress.com/item/4000739457722.html?gatewayAdapt=glo2deu
fingerprint profileId:'0104', endpointId:'01', inClusters:'0004,0005,EF00,0000', outClusters:'0019,000A', model:'TS0601', manufacturer:'_TZE200_bjawzodf', deviceJoinName: 'Tuya like Temperature Humidity LCD Display' // https://de.aliexpress.com/item/4000739457722.html?gatewayAdapt=glo2deu
fingerprint profileId:'0104', endpointId:'01', inClusters:'0004,0005,EF00,0000', outClusters:'0019,000A', model:'TS0601', manufacturer:'_TZE200_zl1kmjqx', deviceJoinName: 'Tuya Temperature Humidity sensor MIR-TE100-TY' // https://www.aliexpress.com/item/1005002836127648.html
fingerprint profileId:'0104', endpointId:'01', inClusters:'0000,0004,0005,EF00', outClusters:'0019,000A', model:'TS0601', manufacturer:'_TZE200_qyflbnbj', deviceJoinName: 'Tuya Temperature Humidity sensor MIR-TE100-TY' // https://www.aliexpress.com/item/1005002836127648.html
fingerprint profileId:'0104', endpointId:'01', inClusters:'0000,0004,0005,EF00', outClusters:'0019,000A', model:'TS0601', manufacturer:'_TZE204_qyflbnbj', deviceJoinName: 'Tuya Temperature Humidity sensor MIR-TE100-TY' // https://community.hubitat.com/t/release-tuya-temperature-humidity-illuminance-lcd-display-with-a-clock-w-healthstatus/88093/522?u=kkossev
fingerprint profileId:'0104', endpointId:'01', inClusters:'0004,0005,EF00,0000', outClusters:'0019,000A', model:'TS0601', manufacturer:'_TZE200_myd45weu', deviceJoinName: 'Tuya Temperature Humidity Soil Monitoring Sensor' //
fingerprint profileId:'0104', endpointId:'01', inClusters:'0000,0004,0005,EF00', outClusters:'0019,000A', model:'TS0601', manufacturer:'_TZE204_myd45weu', deviceJoinName: 'Tuya Temperature Humidity Soil Monitoring Sensor' // https://www.aliexpress.com/item/1005004979025740.html
fingerprint profileId:'0104', endpointId:'01', inClusters:'0004,0005,EF00,0000', outClusters:'0019,000A', model:'TS0601', manufacturer:'_TZE200_ga1maeof', deviceJoinName: 'Tuya Temperature Humidity Soil Monitoring Sensor' // https://www.aliexpress.com/item/1005004979025740.html
fingerprint profileId:"0104", endpointId:"01", inClusters:"0004,0005,EF00,0000,ED00", outClusters:"0019,000A", model:"TS0601", manufacturer:"_TZE284_aao3yzhs", controllerType: "ZGB", deviceJoinName: 'Tuya Temperature Humidity Soil Monitoring Sensor II'
// model: 'ZG-227ZL',
fingerprint profileId:'0104', endpointId:'01', inClusters:'0000,0001,0004,0005,0402,0405,EF00', outClusters:'0019,000A', model:'TS0601', manufacturer:'_TZE200_qoy0ekbd', deviceJoinName: 'Tuya Temperature Humidity LCD Display' // not tested
fingerprint profileId:'0104', endpointId:'01', inClusters:'0000,0001,0004,0005,0402,0405,EF00', outClusters:'0019,000A', model:'TS0601', manufacturer:'_TZE200_a8sdabtg', deviceJoinName: 'Tuya Temperature Humidity (no screen)' // https://community.hubitat.com/t/new-temp-humidity-device-not-working-correctly-generic-zigbee-th-driver/109725?u=kkossev
fingerprint profileId:'0104', endpointId:'01', inClusters:'0001,0402,0405,0000', outClusters:'0019,000A', model:'TS0601', manufacturer:'_TZE200_znbl8dj5', deviceJoinName: 'Tuya Temperature Humidity' // kk
//
// requre more Tuya Magic - queryOnDeviceAnnounce !!! https://github.com/Koenkk/zigbee-herdsman-converters/blob/c7e670672eb9c584429fe5462eb835c0ae9b0da0/src/lib/tuya.ts#L45
fingerprint profileId:'0104', endpointId:'01', inClusters:'0004,0005,EF00,0000', outClusters:'0019,000A', model:'TS0601', manufacturer:'_TZE200_yjjdcqsq', deviceJoinName: 'Tuya Temperature Humidity' // kk
fingerprint profileId:'0104', endpointId:'01', inClusters:'0004,0005,EF00,0000', outClusters:'0019,000A', model:'TS0601', manufacturer:'_TZE204_yjjdcqsq', deviceJoinName: 'Tuya Temperature Humidity'
fingerprint profileId:'0104', endpointId:'01', inClusters:'0004,0005,EF00,0000', outClusters:'0019,000A', model:'TS0601', manufacturer:'_TZE200_9yapgbuv', deviceJoinName: 'Tuya Temperature Humidity'
fingerprint profileId:'0104', endpointId:'01', inClusters:'0004,0005,EF00,0000', outClusters:'0019,000A', model:'TS0601', manufacturer:'_TZE204_9yapgbuv', deviceJoinName: 'Tuya Temperature Humidity'
fingerprint profileId:'0104', endpointId:'01', inClusters:'0004,0005,EF00,0000', outClusters:'0019,000A', model:'TS0601', manufacturer:'_TZE200_upagmta9', deviceJoinName: 'Tuya Temperature Humidity'
fingerprint profileId:'0104', endpointId:'01', inClusters:'0004,0005,EF00,0000', outClusters:'0019,000A', model:'TS0601', manufacturer:'_TZE204_upagmta9', deviceJoinName: 'Tuya Temperature Humidity'
fingerprint profileId:'0104', endpointId:'01', inClusters:'0004,0005,EF00,0000', outClusters:'0019,000A', model:'TS0601', manufacturer:'_TZE200_cirvgep4', deviceJoinName: 'Tuya Temperature Humidity LCD Display with a Clock' //https://community.hubitat.com/t/release-tuya-temperature-humidity-illuminance-lcd-display-with-a-clock-w-healthstatus/88093/308?u=kkossev
fingerprint profileId:'0104', endpointId:'01', inClusters:'0004,0005,EF00,0000', outClusters:'0019,000A', model:'TS0601', manufacturer:'_TZE200_ysm4dsb1', deviceJoinName: 'Tuya Temperature Humidity' // not tested ! https://github.com/Koenkk/zigbee2mqtt/issues/20815
fingerprint profileId:'0104', endpointId:'01', inClusters:'0004,0005,EF00,0000', outClusters:'0019,000A', model:'TS0601', manufacturer:'_TZE0204_yjjdcqsq', deviceJoinName: 'Tuya Temperature Humidity' // not tested !https://github.com/Koenkk/zigbee2mqtt/issues/20235
// kk
//
fingerprint profileId:'0104', endpointId:'01', inClusters:'0004,0005,EF00,0000', outClusters:'0019,000A', model:'TS0601', manufacturer:'_TZE200_whkgqxse', deviceJoinName: 'Tuya Zigbee Temperature Humidity Sensor With Backlight' // https://www.aliexpress.com/item/1005003980647546.html
fingerprint profileId:'0104', endpointId:'01', inClusters:'0001,0003,0402,0405,0000', outClusters:'0003,0019,000A', model:'TS0201', manufacturer:'_TZ3000_bguser20', deviceJoinName: 'Tuya Temperature Humidity sensor WSD500A'
fingerprint profileId:'0104', endpointId:'01', inClusters:'0001,0003,0402,0405,0000', outClusters:'0003,0019,000A', model:'TS0201', manufacturer:'_TZ3000_xr3htd96', deviceJoinName: 'Tuya Temperature Humidity sensor WSD500A'
fingerprint profileId:'0104', endpointId:'01', inClusters:'0001,0003,0402,0405,0000', outClusters:'0003,0019,000A', model:'TS0201', manufacturer:'_TZ3000_fllyghyj', deviceJoinName: 'Tuya Temperature Humidity sensor' // not tested
fingerprint profileId:'0104', endpointId:'01', inClusters:'0001,0003,0402,0405,0000', outClusters:'0003,0019,000A', model:'TS0201', manufacturer:'_TZ3000_yd2e749y', deviceJoinName: 'Tuya Temperature Humidity sensor' // not tested
fingerprint profileId:'0104', endpointId:'01', inClusters:'0001,0003,0402,0405,0000', outClusters:'0003,0019,000A', model:'TS0201', manufacturer:'_TZ3000_6uzkisv2', deviceJoinName: 'Tuya Temperature Humidity sensor' // not tested
fingerprint profileId:'0104', endpointId:'01', inClusters:'0001,0003,0402,0405,0000', outClusters:'0003,0019,000A', model:'TS0201', manufacturer:'_TZ3000_dowj6gyi', deviceJoinName: 'Tuya Temperature Humidity sensor' // https://community.hubitat.com/t/tuya-humidity-temperature-sensor/76635/79?u=kkossev
fingerprint profileId:'0104', endpointId:'01', inClusters:'0001,0003,0402,0405,0000', outClusters:'0003,0019,000A', model:'TS0201', manufacturer:'_TZ3000_8ybe88nf', deviceJoinName: 'Tuya Temperature Humidity sensor' // https://community.hubitat.com/t/release-tuya-temperature-humidity-illuminance-lcd-display-with-a-clock-w-healthstatus/88093/262?u=kkossev
fingerprint profileId:'0104', endpointId:'01', inClusters:'0001,0003,0402,0405,0000', outClusters:'0003,0019,000A', model:'TS0201', manufacturer:'_TZ3000_rdhukkmi', deviceJoinName: 'Tuya Temperature Humidity sensor' // https://community.hubitat.com/t/tuya-humidity-temperature-sensor/76635/55?u=kkossev
fingerprint profileId:'0104', endpointId:'01', inClusters:'0001,0003,0402,0405,0000', outClusters:'0003,0019,000A', model:'TS0201', manufacturer:'_TZ3000_utwgoauk', deviceJoinName: 'Tuya Temperature Humidity sensor' // https://community.hubitat.com/t/humidity-sensor-usb-powered-zigbee/127569/14?u=kkossev
//
fingerprint profileId:'0104', endpointId:'01', inClusters:'0000,0001,0003,0402,0405', outClusters:'0003,0402,0405', model:'RH3052', manufacturer:'TUYATEC-gqhxixyk', deviceJoinName: 'TUYATEC RH3052 Motion Sensor' // https://community.hubitat.com/t/moes-zigbee-3-0-temp-humidity-sensor-driver/112318?u=kkossev
//
fingerprint profileId:'0104', endpointId:'01', inClusters:'0000,0003,0402,0405,0001', outClusters:'0003', model:'TH01', manufacturer:'eWeLink', deviceJoinName: 'Sonoff Temperature and Humidity Sensor SNZB-02'
fingerprint profileId:'0104', endpointId:'01', inClusters:'0000,0003,0402,0405,0001', outClusters:'0003', model:'TH01', manufacturer:'SONOFF', deviceJoinName: 'Sonoff Temperature and Humidity Sensor SNZB-02'
fingerprint profileId:'0104', endpointId:'01', inClusters:'0000,0001,0003,0020,0402,0405,FC57,FC11', outClusters:'0019', model:'SNZB-02D', manufacturer:'SONOFF', deviceJoinName: 'Sonoff Temperature and Humidity Sensor SNZB-02D'
fingerprint profileId:'0104', endpointId:'01', inClusters:'0000,0001,0003,0020,0402,0405,FC57,FC11', outClusters:'0019', model:'SNZB-02D', manufacturer:'eWeLink', deviceJoinName: 'Sonoff Temperature and Humidity Sensor SNZB-02D'
fingerprint profileId:'0104', endpointId:'01', inClusters:'0001,0020,0000,0003,0402', outClusters:'0003', model:'THS317-ET', manufacturer:'OWON', deviceJoinName: 'OWON Temperature sensor' // https://community.hubitat.com/t/newbie-help-with-owon-ths317-et-multi-sensor/122671/5?u=kkossev
fingerprint profileId:'0104', endpointId:'01', inClusters:'0000,0001,0003,0020,0402,0405,FC57,FC11', outClusters:'0019', model:'SNZB-02P', manufacturer:'eWeLink', deviceJoinName: 'Sonoff Temperature and Humidity Sensor SNZB-02P' // https://community.hubitat.com/t/release-tuya-temperature-humidity-illuminance-lcd-display-with-a-clock-w-healthstatus/88093/435?u=kkossev
fingerprint profileId:'0104', endpointId:'01', inClusters:'0000,0001,0003,0020,0402,0405,FC57,FC11', outClusters:'0019', model:'SNZB-02P', manufacturer:'SONOFF', deviceJoinName: 'Sonoff Temperature and Humidity Sensor SNZB-02P'
//
fingerprint profileId:'0104', endpointId:'01', inClusters:'0000,0001,0003,0400,0402,0405,0B05,FCC0', outClusters:'0019', model:'TS0222', manufacturer:'_TYZB01_fi5yftwv', deviceJoinName: 'Konke THI Sensor KK-ES-J01W'
fingerprint profileId:'0104', endpointId:'01', inClusters:'0004,0005,EF00,0000', outClusters:'0019,000A', model:'TS0601', manufacturer:'_TZE200_vvmbj46n', deviceJoinName: 'Tuya Zigbee Temperature Humidity Sensor With Backlight' // TODO - configuration options! +onEventSetTime // https://github.com/Koenkk/zigbee2mqtt/issues/19731
fingerprint profileId:'0104', endpointId:'01', inClusters:'0000,0001,0003,0020,0402,0405', outClusters:'0019', model:'3RTHS0224Z', manufacturer:'Third Reality', controllerType: 'ZGB', deviceJoinName: 'ThidReality Temperature Humidity Sensor'
fingerprint profileId:'0104', endpointId:'01', inClusters:'0000,0001,0402,0405', outClusters:'0019', model:'3RTHS24BZ', manufacturer:'Third Reality, Inc', controllerType: 'ZGB', deviceJoinName: 'ThidReality Temperature Humidity Sensor'
fingerprint profileId:'0104', endpointId:'01', inClusters:'0000,0003,0004,0005,0006,E001,E000,EF00', outClusters:'000A,0019', model:'TS000F', manufacturer:'_TZ3218_7fiyo3kv', deviceJoinName: 'MHCOZY switch with temp sensor' // https://community.hubitat.com/t/mycozy-switch-with-temp-sensor-driver/139715?u=kkossev
}
preferences {
input(name: 'txtEnable', type: 'bool', title: 'Description text logging', description: 'Display measured values in HE log page.
The recommended setting is enabled.', defaultValue: true)
input(name: 'logEnable', type: 'bool', title: 'Debug logging', description: 'Debug information, useful for troubleshooting.
The recommended value is disabled.', defaultValue: true)
input(name: 'modelGroupPreference', type: 'enum', title: 'Model Group', description:'The recommended setting is Auto detect.', defaultValue: 0, options:
['Auto detect':'Auto detect', 'TS0601_Tuya':'TS0601_Tuya', 'TS0601_Tuya_2':'TS0601_Tuya_2', 'TS0601_Haozee':'TS0601_Haozee', 'TS0601_AUBESS':'TS0601_AUBESS', 'TS0201':'TS0201', 'TS0222':'TS0222', 'TS0201_LCZ030': 'TS0201_LCZ030',
'TS0222_2':'TS0222_2', 'TS0201_TH':'TS0201_TH', 'TS0601_Soil':'TS0601_Soil', , 'TS0601_Soil_II':'TS0601_Soil_II', 'Zigbee NON-Tuya':'Zigbee NON-Tuya', 'OWON':'OWON', 'DS18B20':'DS18B20'])
input(name: 'advancedOptions', type: 'bool', title: 'Advanced options', description: 'May not be supported by all devices!', defaultValue: false)
if (advancedOptions == true) {
if (isConfigurableSleepyDevice()) {
input(title: 'To configure a sleepy device, try any of the methods below :', description: ' * Rapidly change the temperature or the humidity
* Remove the battery for at least 1 minute
* Pair the device again to HE', type: 'paragraph', element: 'paragraph')
}
configParams.each {
if (it.value.input.limit == null || 'ALL' in it.value.input.limit || getModelGroup() in it.value.input.limit) {
input it.value.input
}
}
}
}
}
@Field static Map configParams = [
0: [input: [name: 'temperatureOffset', type: 'decimal', title: 'Temperature offset', description: 'Select how many degrees to adjust the temperature.', defaultValue: 0.0, range: '-100.0..100.0',
limit:['ALL']]],
1: [input: [name: 'humidityOffset', type: 'decimal', title: 'Humidity offset', description: 'Enter a percentage to adjust the humidity.', defaultValue: 0.0, range: '-100.0..100.0',
limit:['ALL']]],
2: [input: [name: 'temperatureSensitivity', type: 'decimal', title: 'Temperature Sensitivity', description: 'Temperature change for reporting, ' + '\u00B0' + 'C', defaultValue: 0.5, range: '0.1..5.0',
limit:['TS0601_Tuya', 'TS0601_Haozee', 'TS0201_TH', 'Zigbee NON-Tuya', 'TS0601_Tuya_2']]],
3: [input: [name: 'humiditySensitivity', type: 'number', title: 'Humidity Sensitivity', description: 'Humidity change for reporting, %', defaultValue: 5, range: '1..10',
limit:['TS0601_Tuya', 'TS0601_Haozee', 'TS0201_TH', 'Zigbee NON-Tuya', 'TS0601_Tuya_2']]],
4: [input: [name: 'illuminanceSensitivity', type: 'number', title: 'Illuminance Sensitivity', description: 'Illuminance change for reporting, %', defaultValue: 12, range: '10..100', // TS0222 "MOES ZSS-ZK-THL"
limit:['TS0222']]],
5: [input: [name: 'minTempAlarmPar', type: 'decimal', title: 'Minimum Temperature Alarm', description: 'Minimum Temperature Alarm, C', defaultValue: 0.0, range: '-20.0..60.0',
limit:['TS0601_Tuya', /*'TS0601_Haozee',*/ 'TS0201_LCZ030']]],
6: [input: [name: 'maxTempAlarmPar', type: 'decimal', title: 'Maximum Temperature Alarm', description: 'Maximum Temperature Alarm, C', defaultValue: 39.0, range: '-20.0..60.0',
limit:['TS0601_Tuya', /*'TS0601_Haozee',*/ 'TS0201_LCZ030']]],
7: [input: [name: 'minHumidityAlarmPar', type: 'number', title: 'Minimal Humidity Alarm', description: 'Minimum Humidity Alarm, %', defaultValue: 20, range: '0..100', // 'TS0601_Haozee' only!
limit:[/*'TS0601_Haozee',*/ /*'TS0201_LCZ030'*/]]],
8: [input: [name: 'maxHumidityAlarmPar', type: 'number', title: 'Maximum Humidity Alarm', description: 'Maximum Humidity Alarm, %', defaultValue: 60, range: '0..100', // 'TS0601_Haozee' only!
limit:[/*'TS0601_Haozee',*/ /*'TS0201_LCZ030'*/]]],
9: [input: [name: 'minReportingTimeTemp', type: 'number', title: 'Minimum time between temperature reports', description: 'Minimum time between temperature reporting, seconds.', defaultValue: 10, range: '1..3600',
limit:['ALL']]],
10: [input: [name: 'maxReportingTimeTemp', type: 'number', title: 'Maximum time between temperature reports', description: 'Maximum time between temperature reporting, seconds.', defaultValue: 3600, range: '10..43200',
limit:['TS0601_Haozee', 'TS0201_TH', 'Zigbee NON-Tuya']]],
11: [input: [name: 'minReportingTimeHumidity', type: 'number', title: 'Minimum time between humidity reports', description: 'Minimum time between humidity reporting, seconds.', defaultValue: 10, range: '1..3600',
limit:['ALL']]],
12: [input: [name: 'maxReportingTimeHumidity', type: 'number', title: 'Maximum time between humidity reports', description: 'Maximum time between humidity reporting, seconds.', defaultValue: 3600, range: '10..43200',
limit:['TS0601_Haozee', 'TS0201_TH', 'Zigbee NON-Tuya']]],
13: [input: [name: 'alarmTempPar', type: 'enum', title: 'Temperature Alarm', description:'Temperature Alarm', defaultValue: 0, options: [0:'Below min temp', 1:'Over max temp', 2:'off'],
limit:[/*'TS0201_LCZ030'*/]]],
14: [input: [name: 'alarmHumidityPar', type: 'enum', title: 'Humidity Alarm', description:'Temperature Alarm', defaultValue: 0, options: [0:'Below min hum.', 1:'Over max hum', 2:'off'],
limit:[/*'TS0201_LCZ030'*/]]]
]
@Field static final Map Models = [
'_TZE200_lve3dvpy' : 'TS0601_Tuya', // Tuya Temperature Humidity LCD Display with a Clock
'_TZE200_c7emyjom' : 'TS0601_Tuya', // Tuya Temperature Humidity LCD Display with a Clock
'_TZE200_whkgqxse' : 'TS0601_Tuya', // Tuya Zigbee Temperature Humidity Sensor With Backlight https://www.aliexpress.com/item/1005003980647546.html
'_TZE200_a8sdabtg' : 'TS0601_Tuya', // Tuya Zigbee Temperature Humidity Sensor - no display! https://www.amazon.de/gp/product/B09NKCDXT9 - TODO !
'_TZE200_qoy0ekbd' : 'TS0601_Tuya', // https://www.aliexpress.com/item/1005004896603070.html - TODO !
'_TZE200_znbl8dj5' : 'TS0601_Tuya', // https://www.aliexpress.com/item/1005004116638127.html - TODO !
'_TZE200_zl1kmjqx' : 'TS0601_Tuya', // https://www.aliexpress.com/item/1005002836127648.html
'_TZE200_qyflbnbj' : 'TS0601_Tuya', // not tested
'_TZE204_qyflbnbj' : 'TS0601_Tuya', // https://community.hubitat.com/t/release-tuya-temperature-humidity-illuminance-lcd-display-with-a-clock-w-healthstatus/88093/522?u=kkossev
'_TZE200_nnrfa68v' : 'TS0601_Tuya', // NOUS E6 https://community.hubitat.com/t/nous-humidity-and-temp-sensor/137764/7?u=kkossev
'_TZE200_cirvgep4' : 'TS0601_Tuya_2', // https://www.aliexpress.com/item/1005005198387789.html
'_TZE200_yjjdcqsq' : 'TS0601_Tuya_2', // https://community.hubitat.com/t/release-tuya-temperature-humidity-illuminance-lcd-display-with-a-clock-w-healthstatus/88093/446?u=kkossev
'_TZE204_yjjdcqsq' : 'TS0601_Tuya_2', // https://community.hubitat.com/t/newbie-help-with-owon-ths317-et-multi-sensor/122671/18?u=kkossev
'_TZE200_9yapgbuv' : 'TS0601_Tuya_2', // not tested
'_TZE204_9yapgbuv' : 'TS0601_Tuya_2', // not tested
'_TZE200_upagmta9' : 'TS0601_Tuya_2', // not tested
'_TZE204_upagmta9' : 'TS0601_Tuya_2', // not tested // https://github.com/zigpy/zha-device-handlers/issues/2694
'_TZE200_vvmbj46n' : 'TS0601_Tuya_2', // https://community.hubitat.com/t/looking-for-a-zigbee-temperature-humidity-illumination-sensor-with-display/130896/14?u=kkossev
'_TZE204_vvmbj46n' : 'TS0601_Tuya_2', //
'_TZE200_locansqn' : 'TS0601_Haozee', // Haozee Temperature Humidity Illuminance LCD Display with a Clock
'_TZE200_bq5c8xfe' : 'TS0601_Haozee', //
'_TZE200_pisltm67' : 'TS0601_AUBESS', // illuminance only sensor
'_TZ2000_a476raq2' : 'TS0201', // KK
'_TZ3000_lfa05ajd' : 'TS0201', // Zemismart ZXZTH
'_TZ2000_xogb73am' : 'TS0201',
'_TZ2000_avdnvykf' : 'TS0201',
'_TYZB01_a476raq2' : 'TS0201',
'_TYZB01_hjsgdkfl' : 'TS0201',
'_TZ2000_hjsgdkfl' : 'TS0201', // "AVATTO S-H02"
'_TZ3000_bguser20' : 'TS0201', // Model WSD500A
'_TZ3000_xr3htd96' : 'TS0201', // Model WSD500A
'_TZ3000_fllyghyj' : 'TS0201',
'_TZ3000_yd2e749y' : 'TS0201',
'_TZ3000_6uzkisv2' : 'TS0201',
'_TZ3000_dowj6gyi' : 'TS0201', // https://community.hubitat.com/t/release-tuya-temperature-humidity-illuminance-lcd-display-with-a-clock-w-healthstatus/88093/512?u=kkossev
'_TZ3000_8ybe88nf' : 'TS0201',
'_TZ3000_rdhukkmi' : 'TS0201',
'_TZ3000_utwgoauk' : 'TS0201',
'TUYATEC-gqhxixyk' : 'TS0201', // model RH3052
'_TZ3000_qaaysllp' : 'TS0201_LCZ030', // NAS-TH02B / NEO Coolcam ? - T/H/I - testing! // https://github.com/Datakg/tuya/blob/53e33ae7767aedbb5d2138f2a31798badffd80d2/zhaquirks/tuya/ts0201_neo.py
'_TYZB01_kvwjujy9' : 'TS0222', // "MOES ZSS-ZK-THL" e-Ink display
'_TYZB01_ftdkanlj' : 'TS0222', // https://community.hubitat.com/t/release-tuya-temperature-humidity-illuminance-lcd-display-with-a-clock-w-healthstatus/88093/419?u=kkossev
'_TYZB01_fi5yftwv' : 'TS0222', // https://community.hubitat.com/t/konke-bond-series-enviroment-sensor/126445?u=kkossev
'_TYZB01_4mdqxxnn' : 'TS0222_2', // illuminance only sensor
'_TZE200_pay2byax' : 'TS0601_Contact', // Contact and illuminance sensor
'_TZ3000_itnrsufe' : 'TS0201_TH', // Temperature and humidity sensor; // reports both battery voltage and perceintage; cluster 0xE002, attr 0xE00B: 0-Celsius, 1: Fahrenheit ( 0x30 ENUM)
'_TZ3000_ywagc4rj' : 'TS0201_TH', // https://community.hubitat.com/t/release-tuya-temperature-humidity-illuminance-lcd-display-with-a-clock/88093/210?u=kkossev
'_TZ3210_ncw88jfq' : 'TS0201_TH', // https://community.hubitat.com/t/release-tuya-temperature-humidity-illuminance-lcd-display-with-a-clock-w-healthstatus/88093/436?u=kkossev
'_TZE200_myd45weu' : 'TS0601_Soil', // Soil monitoring sensor
'_TZE204_myd45weu' : 'TS0601_Soil', // https://community.hubitat.com/t/release-tuya-temperature-humidity-illuminance-lcd-display-with-a-clock-w-healthstatus/88093/519?u=kkossev
'_TZE200_ga1maeof' : 'TS0601_Soil', // Soil monitoring sensor
'_TZE284_aao3yzhs' : 'TS0601_Soil_II', // Soil monitoring sensor II
'eWeLink' : 'Zigbee NON-Tuya', // Sonoff Temperature and Humidity Sensor SNZB-02, SNZB-02D, SNZB-02P
'SONOFF' : 'Zigbee NON-Tuya', // Sonoff Temperature and Humidity Sensor SNZB-02, SNZB-02D, SNZB-02P
'ShinaSystem' : 'Zigbee NON-Tuya', // USM-300Z
'Third Reality' : 'Zigbee NON-Tuya', //
'Third Reality, Inc': 'Zigbee NON-Tuya', //
'OWON' : 'OWON', // model:"THS317-ET", manufacturer:"OWON"
'_TZ3218_7fiyo3kv' : 'DS18B20', // MHCOZY switch with temp sensor
'' : 'UNKNOWN',
'ALL' : 'ALL',
'TEST' : 'TEST'
]
@Field static final Map deviceProfilesV3 = [
'SONOFF_TEMP_HUMI' : [
models : ['TH01', 'SNZB-02D', 'SNZB-02P'],
manufacturers : ['eWeLink', 'SONOFF'],
fingerprints : [
[profileId:'0104', endpointId:'01', inClusters:'0000,0003,0402,0405,0001', outClusters:'0003', model:'TH01', manufacturer:'eWeLink', deviceJoinName: 'Sonoff Temperature and Humidity Sensor SNZB-02'],
[profileId:'0104', endpointId:'01', inClusters:'0000,0003,0402,0405,0001', outClusters:'0003', model:'TH01', manufacturer:'SONOFF', deviceJoinName: 'Sonoff Temperature and Humidity Sensor SNZB-02'],
[profileId:'0104', endpointId:'01', inClusters:'0000,0001,0003,0020,0402,0405,FC57,FC11', outClusters:'0019', model:'SNZB-02D', manufacturer:'eWeLink', deviceJoinName: 'Sonoff Temperature and Humidity Sensor SNZB-02D'],
[profileId:'0104', endpointId:'01', inClusters:'0000,0001,0003,0020,0402,0405,FC57,FC11', outClusters:'0019', model:'SNZB-02D', manufacturer:'SONOFF', deviceJoinName: 'Sonoff Temperature and Humidity Sensor SNZB-02D'],
[profileId:'0104', endpointId:'01', inClusters:'0000,0001,0003,0020,0402,0405,FC57,FC11', outClusters:'0019', model:'SNZB-02P', manufacturer:'eWeLink', deviceJoinName: 'Sonoff Temperature and Humidity Sensor SNZB-02P'],
[profileId:'0104', endpointId:'01', inClusters:'0000,0001,0003,0020,0402,0405,FC57,FC11', outClusters:'0019', model:'SNZB-02P', manufacturer:'SONOFF', deviceJoinName: 'Sonoff Temperature and Humidity Sensor SNZB-02P']
],
deviceJoinName: 'Sonoff Temperature and Humidity Sensor',
capabilities : ['battery': true],
attributes : ['healthStatus': 'unknown', 'powerSource': 'battery'],
configuration : ['battery': false],
preferences : [
'powerOnBehaviour' : [ name: 'powerOnBehaviour', type: 'enum', title: 'Power-On Behaviour', description:'Select Power-On Behaviour', defaultValue: '2', options: ['0': 'closed', '1': 'open', '2': 'last state']] //,
]
]
]
def isConfigurableSleepyDevice() { getModelGroup() in ['Zigbee NON-Tuya', 'TS0201_TH'] }
@Field static final Integer MaxRetries = 3
@Field static final Integer ConfigTimer = 15
@Field static final Integer presenceCountTreshold = 4
@Field static final Integer defaultMinReportingTime = 10
@Field static final Integer REFRESH_TIMER = 3000
@Field static final Integer COMMAND_TIMEOUT = 10
@Field static final Integer MAX_PING_MILISECONDS = 10000 // rtt more than 10 seconds will be ignored
@Field static String UNKNOWN = 'UNKNOWN'
private getCLUSTER_TUYA() { 0xEF00 }
private getSETDATA() { 0x00 }
private getSETTIME() { 0x24 }
// Tuya Commands
private getTUYA_REQUEST() { 0x00 }
private getTUYA_REPORTING() { 0x01 }
private getTUYA_QUERY() { 0x02 }
private getTUYA_STATUS_SEARCH() { 0x06 }
private getTUYA_TIME_SYNCHRONISATION() { 0x24 }
// tuya DP type
private getDP_TYPE_RAW() { '01' } // [ bytes ]
private getDP_TYPE_BOOL() { '01' } // [ 0/1 ]
private getDP_TYPE_VALUE() { '02' } // [ 4 byte value ]
private getDP_TYPE_STRING() { '03' } // [ N byte string ]
private getDP_TYPE_ENUM() { '04' } // [ 0-255 ]
private getDP_TYPE_BITMAP() { '05' } // [ 1,2,4 bytes ] as bits
// Parse incoming device messages to generate events
def parse(String description) {
checkDriverVersion()
setPresent()
Map statsMap = stringToJsonMap(state.stats); try { statsMap['rxCtr']++ } catch (e) { statsMap['rxCtr'] = 1 }; state.stats = mapToJsonString(statsMap)
if (settings?.logEnable) { log.debug "${device.displayName} parse() descMap =${zigbee.parseDescriptionAsMap(description)} description = ${description}" }
if (description?.startsWith('catchall:') || description?.startsWith('read attr -')) {
Map descMap = zigbee.parseDescriptionAsMap(description)
if (descMap.clusterInt == 0x0001 && descMap.commandInt != 0x07 && descMap?.value) {
if (descMap.attrInt == 0x0021) {
getBatteryPercentageResult(Integer.parseInt(descMap.value, 16))
} else if (descMap.attrInt == 0x0020) {
//log.trace "descMap.attrInt == 0x0020"
getBatteryVoltageResult(Integer.parseInt(descMap.value, 16))
}
else {
log.warn "unparesed attrint $descMap.attrInt"
}
}
else if (descMap.cluster == '0400' && descMap.attrId == '0000') {
def rawLux = Integer.parseInt(descMap.value, 16)
if (device.getDataValue('manufacturer') in ['ShinaSystem']) {
illuminanceEventLux( rawLux )
}
else {
illuminanceEvent( rawLux )
}
if (getModelGroup() == 'TS0222') {
pollTS0222()
}
}
else if (descMap.cluster == '0400' && descMap.attrId == 'F001') { //MOES ZSS-ZK-THL, also TS0201 Neo Coolcam!
def raw = Integer.parseInt(descMap.value, 16)
if (settings?.txtEnable) { log.info "${device.displayName} illuminance sensitivity is ${raw} Lux" }
device.updateSetting('illuminanceSensitivity', [value:raw, type:'number'])
}
else if (descMap.cluster == '0402' && descMap.attrId == '0000') {
if (getModelGroup() != 'TS0222_2') {
def raw = Integer.parseInt(descMap.value, 16)
if (raw > 32767) {
//Here we deal with negative values
raw = raw - 65536
}
temperatureEvent( raw / 100.0 )
}
else {
if (settings?.logEnable) { log.warn "${device.displayName} Ignoring ${getModelGroup()} temperature event" }
}
}
else if (descMap.cluster == '0405' && descMap.attrId == '0000') {
def raw = Integer.parseInt(descMap.value, 16)
if (getModelGroup() != 'TS0201_TH') {
humidityEvent( raw / 100.0 )
}
else {
humidityEvent( raw / 10.0 ) // also _TZE200_bjawzodf, _TZE200_zl1kmjqx ?
}
}
else if (descMap.cluster == '0406' && descMap.attrId == '0000') { // OWON, SiHAS
def raw = Integer.parseInt(descMap.value, 16)
motionEvent( raw & 0x01 )
}
else if (descMap.cluster == '0000' && descMap.attrId == '0001') { // ping
// descMap = [raw:0D310100000A01002004, dni:0D31, endpoint:01, cluster:0000, size:0A, attrId:0001, encoding:20, command:01, value:04, clusterInt:0, attrInt:1]
logDebug "Tuya check-in message (attribute ${descMap.attrId} reported: ${descMap?.value})"
def now = new Date().getTime()
Map lastTxMap = stringToJsonMap(state.lastTx)
def timeRunning = now.toInteger() - (lastTxMap.pingTime ?: '0').toInteger()
if (timeRunning < MAX_PING_MILISECONDS && timeRunning > 0) {
sendRttEvent()
}
unschedule('deviceCommandTimeout')
}
else if (descMap?.clusterInt == CLUSTER_TUYA) {
processTuyaCluster( descMap )
}
else if (descMap?.clusterId == '0013') { // device announcement, profileId:0000
logInfo 'device announcement'
try { statsMap['rejoins']++ } catch (e) { statsMap['rejoins'] = 1 }; state.stats = mapToJsonString(statsMap)
if (getModelGroup() == 'TS0222') {
configure()
}
}
else if (descMap.isClusterSpecific == false && descMap.command == '01' ) { //global commands read attribute response
def status = descMap.data[2]
if (status == '86') {
if (settings?.logEnable) { log.warn "${device.displayName} Cluster ${descMap.clusterId} read attribute - NOT SUPPORTED!\r ${descMap}" }
}
else {
if (settings?.logEnable) { log.warn "${device.displayName} UNPROCESSED Global Command : ${descMap}" }
}
}
else if (descMap.profileId == '0000') { //zdo
parseZDOcommand(descMap)
}
else if (descMap.clusterId != null && descMap.profileId == '0104') { // ZHA global command
parseZHAcommand(descMap)
}
else {
if (settings?.logEnable) { log.debug "${device.displayName} NOT PARSED : ${descMap}" }
}
} // if 'catchall:' or 'read attr -'
else {
if (settings?.logEnable) { log.debug "${device.displayName} UNPROCESSED parse() descMap = ${zigbee.parseDescriptionAsMap(description)}" }
}
//
if (isPendingConfig()) {
ConfigurationStateMachine()
}
}
def parseZHAcommand( Map descMap) {
Map lastRxMap = stringToJsonMap(state.lastRx)
Map lastTxMap = stringToJsonMap(state.lastTx)
switch (descMap.command) {
case '01' : //read attribute response. If there was no error, the successful attribute reading would be processed in the main parse() method.
def status = descMap.data[2]
def attrId = descMap.data[1] + descMap.data[0]
if (status == '86') {
if (logEnable) { log.warn "${device.displayName} Read attribute response: unsupported Attributte ${attrId} cluster ${clusterId}" }
}
else {
if (logEnable) { log.debug "${device.displayName} Read attribute response: status code ${status} Attributte ${attrId} cluster ${descMap.clusterId}" }
}
break
case '04' : //write attribute response
if (logEnable) { log.info "${device.displayName} Received Write Attribute Response for cluster:${descMap.clusterId} , data=${descMap.data} (Status: ${descMap.data[0] == '00' ? 'Success' : 'Failure'})" }
break
case '07' : // Configure Reporting Response
if (logEnable) { log.info "${device.displayName} Received Configure Reporting Response for cluster:${descMap.clusterId} , data=${descMap.data} (Status: ${descMap.data[0] == '00' ? 'Success' : 'Failure'})" }
// Status: Unreportable Attribute (0x8c)
break
case '09' : // Command: Read Reporting Configuration Response (0x09)
def status = zigbee.convertHexToInt(descMap.data[0]) // Status: Success (0x00)
//def attr = zigbee.convertHexToInt(descMap.data[3]) * 256 + zigbee.convertHexToInt(descMap.data[2]) // Attribute: OnOff (0x0000)
if (status == 0) {
//def dataType = zigbee.convertHexToInt(descMap.data[4]) // Data Type: Boolean (0x10)
def min = zigbee.convertHexToInt(descMap.data[6]) * 256 + zigbee.convertHexToInt(descMap.data[5])
def max = zigbee.convertHexToInt(descMap.data[8] + descMap.data[7])
def delta = 0
if (descMap.data.size() == 11) {
delta = zigbee.convertHexToInt(descMap.data[10] + descMap.data[9])
}
else if (descMap.data.size() == 10) {
delta = zigbee.convertHexToInt(descMap.data[9])
}
else {
if (logEnable) { log.debug "${device.displayName} descMap.data.size = ${descMap.data.size()}" }
}
logDebug "Received Read Reporting Configuration response (0x09) for cluster:${descMap.clusterId} attribite:${descMap.data[3] + descMap.data[2]}, data=${descMap.data} (Status: ${descMap.data[0] == '00' ? 'Success' : 'Failure'}) min=${min} max=${max} delta=${delta}"
String attributeName
if (descMap.clusterId == '0405') {
attributeName = 'humidity'
lastRxMap.humiCfg = min.toString() + ',' + max.toString() + ',' + delta.toString()
if (lastRxMap.humiCfg == lastTxMap.humiCfg) {
lastTxMap.humiCfgOK = true
}
}
else if (descMap.clusterId == '0402') {
attributeName = 'temperature'
lastRxMap.tempCfg = min.toString() + ',' + max.toString() + ',' + delta.toString()
if (lastRxMap.tempCfg == lastTxMap.tempCfg) {
lastTxMap.tempCfgOK = true
}
}
else if (descMap.clusterId == '0001') {
attributeName = 'battery %'
}
else {
attributeName = descMap.clusterId
}
if (lastTxMap.humiCfgOK == true && lastTxMap.tempCfgOK == true) {
logDebug 'both T&H configured!'
lastTxMap.cfgFailure = false
}
if (txtEnable == true) {
log.info "${device.displayName} Reporting Configuration Response for ${attributeName} (status: ${descMap.data[0] == '00' ? 'Success' : 'Failure'}) is: min=${min} max=${max} delta=${delta}"
}
}
else { // failure
if (logEnable) { log.info "${device.displayName} Not Found (0x8b) Read Reporting Configuration Response for cluster:${descMap.clusterId} attribite:${descMap.data[3] + descMap.data[2]}, data=${descMap.data} (Status: ${descMap.data[0] == '00' ? 'Success' : 'Failure'})" }
}
break
case '0B' : // ZCL Default Response
def status = descMap.data[1]
if (status != '00') {
if (logEnable) { log.info "${device.displayName} Received ZCL Default Response to Command ${descMap.data[0]} for cluster:${descMap.clusterId} , data=${descMap.data} (Status: ${descMap.data[1] == '00' ? 'Success' : 'Failure'})" }
}
break
default :
if (logEnable) { log.warn "${device.displayName} Unprocessed global command: cluster=${descMap.clusterId} command=${descMap.command} attrId=${descMap.attrId} value=${descMap.value} data=${descMap.data}" }
break
}
state.lastRx = mapToJsonString(lastRxMap)
state.lastTx = mapToJsonString(lastTxMap)
}
def parseZDOcommand( Map descMap ) {
switch (descMap.clusterId) {
case '0006' :
if (logEnable) { log.info "${device.displayName} Received match descriptor request, data=${descMap.data} (Sequence Number:${descMap.data[0]}, Input cluster count:${descMap.data[5]} Input cluster: 0x${descMap.data[7] + descMap.data[6]})" }
break
case '0013' : // device announcement
if (logEnable) { log.info "${device.displayName} Received device announcement, data=${descMap.data} (Sequence Number:${descMap.data[0]}, Device network ID: ${descMap.data[2] + descMap.data[1]}, Capability Information: ${descMap.data[11]})" }
break
case '8004' : // simple descriptor response
if (logEnable) { log.info "${device.displayName} Received simple descriptor response, data=${descMap.data} (Sequence Number:${descMap.data[0]}, status:${descMap.data[1]}, lenght:${hubitat.helper.HexUtils.hexStringToInt(descMap.data[4])}" }
parseSimpleDescriptorResponse( descMap )
break
case '8005' : // endpoint response
if (logEnable) { log.info "${device.displayName} Received endpoint response: cluster: ${descMap.clusterId} (endpoint response) endpointCount = ${ descMap.data[4]} endpointList = ${descMap.data[5]}" }
break
case '8021' : // bind response
if (logEnable) { log.info "${device.displayName} Received bind response, data=${descMap.data} (Sequence Number:${descMap.data[0]}, Status: ${descMap.data[1] == '00' ? 'Success' : 'Failure'})" }
break
case '8022' : // unbind response
if (logEnable) { log.info "${device.displayName} Received unbind response, data=${descMap.data} (Sequence Number:${descMap.data[0]}, Status: ${descMap.data[1] == '00' ? 'Success' : 'Failure'})" }
break
case '8034' : // leave response
if (logEnable) { log.info "${device.displayName} Received leave response, data=${descMap.data}" }
break
case '8038' : // Management Network Update Notify
if (logEnable) { log.info "${device.displayName} Received Management Network Update Notify, data=${descMap.data}" }
break
default :
if (logEnable) { log.warn "${device.displayName} Unprocessed ZDO command: cluster=${descMap.clusterId} command=${descMap.command} attrId=${descMap.attrId} value=${descMap.value} data=${descMap.data}" }
break // 2022/09/16
}
}
def processTuyaCluster( descMap ) {
if (descMap?.clusterInt == CLUSTER_TUYA && descMap?.command == '24') { //getSETTIME
if (settings?.logEnable) { log.debug "${device.displayName} time synchronization request from device, descMap = ${descMap}" }
def offset = 0
try {
offset = location.getTimeZone().getOffset(new Date().getTime())
//if (settings?.logEnable) { log.debug "${device.displayName} timezone offset of current location is ${offset}" }
}
catch (e) {
if (settings?.logEnable) { log.error "${device.displayName} cannot resolve current location. please set location in Hubitat location setting. Setting timezone offset to zero" }
}
def cmds = zigbee.command(CLUSTER_TUYA, SETTIME, '0008' + zigbee.convertToHexString((int)(now() / 1000), 8) + zigbee.convertToHexString((int)((now() + offset) / 1000), 8))
// TODO : send raw command without 'need confirmation' frame control !
//if (settings?.logEnable) { log.trace "${device.displayName} now is: ${now()}" } // KK TODO - convert to Date/Time string!
if (settings?.logEnable) { log.debug "${device.displayName} sending time data : ${cmds}" }
cmds.each { sendHubCommand(new hubitat.device.HubAction(it, hubitat.device.Protocol.ZIGBEE)) }
//if (state.txCounter != null) state.txCounter = state.txCounter + 1
}
else if (descMap?.clusterInt == CLUSTER_TUYA && descMap?.command == '0B') { // ZCL Command Default Response
String clusterCmd = descMap?.data[0]
def status = descMap?.data[1]
logDebug "Tuya cluster confirmation for command 0x${clusterCmd} response 0x${status} data = ${descMap?.data}"
if (status != '00') {
if (settings?.logEnable) { log.warn "${device.displayName} ATTENTION! manufacturer = ${device.getDataValue('manufacturer')} group = ${getModelGroup()} unsupported Tuya cluster ZCL command 0x${clusterCmd} response 0x${status} data = ${descMap?.data} !!!" }
}
}
else if ((descMap?.clusterInt == CLUSTER_TUYA) && (descMap?.command == '01' || descMap?.command == '02' || descMap?.command == '06')) { // added command 06 - 06/26/2024
def dataLen = descMap?.data.size()
//log.warn "dataLen=${dataLen}"
//def transid = zigbee.convertHexToInt(descMap?.data[1]) // "transid" is just a "counter", a response will have the same transid as the command
for (int i = 0; i < (dataLen - 4); ) {
def dp = zigbee.convertHexToInt(descMap?.data[2 + i]) // "dp" field describes the action/message of a command frame
def dp_id = zigbee.convertHexToInt(descMap?.data[3 + i]) // "dp_identifier" is device dependant
def fncmd_len = zigbee.convertHexToInt(descMap?.data[5 + i])
def fncmd = getTuyaAttributeValue(descMap?.data, i) //
if (settings?.logEnable) { log.trace "${device.displayName} dp_id=${dp_id} dp=${dp} fncmd=${fncmd} fncmd_len=${fncmd_len} (index=${i})" }
processTuyaDP( descMap, dp, dp_id, fncmd)
i = i + fncmd_len + 4
//log.warn "next index is : ${i}"
}
//log.warn "##### end of parsing ####"
} // if (descMap?.command == "01" || descMap?.command == "02")
else {
if (settings?.logEnable) { log.warn "${device.displayName} Unprocessed Tuya cluster command: cluster=${descMap.clusterId} command=${descMap.command} attrId=${descMap.attrId} value=${descMap.value} data=${descMap.data}" }
}
}
def processTuyaDP( descMap, dp, dp_id, fncmdPar) {
def fncmd = fncmdPar
switch (dp) {
case 0x01 : // temperature in C for most models
if (getModelGroup() == 'TS0601_Contact') {
def value = fncmd == 0 ? 'closed' : 'open' // inverted!
sendEvent('name': 'contact', 'value': value)
if (settings?.txtEnable) { log.info "${device.displayName} Contact is ${value}" }
}
else if (getModelGroup() == 'DS18B20') {
logInfo "DS18B20 Switch is ${fncmd}"
}
else if (getModelGroup() != 'TS0601_AUBESS') { // temperature in C, including 'TS0601_Tuya_2'
if (fncmd > 32767) {
//Here we deal with negative values
fncmd = fncmd - 65536
}
temperatureEvent( fncmd / 10.0 )
}
else {
def lomihi = fncmd == 0 ? 'low' : fncmd == 1 ? 'medium' : fncmd == 2 ? 'high' : 'unknown'
if (settings?.logEnable) { log.debug "${device.displayName} Tuya illuminance status is: ${lomihi} (dp_id=${dp_id} dp=${dp} fncmd=${fncmd})" }
}
break
case 0x02 : // humidity % for most of the models; 'TS0601_Contact'illuminance; 'TS0601_Contact'0 battery %
if (getModelGroup() == 'TS0601_AUBESS') {
illuminanceEventLux( safeToInt( fncmd ) )
}
else if (getModelGroup() == 'TS0601_Contact') {
getBatteryPercentageResult(fncmd * 2)
}
else {
if (device.getDataValue('manufacturer') in ['_TZE200_bjawzodf', '_TZE200_zl1kmjqx']) {
humidityEvent( (fncmd / 10.0) as int )
}
else {
humidityEvent( fncmd ) // including 'TS0601_Tuya_2'
}
}
break
case 0x03 : // humidity or illuminance or battery state
if (getModelGroup() in ['TS0601_Soil', 'TS0601_Soil_II']) {
logDebug "Soil Sensor humidity raw = ${fncmd}"
humidityEvent( fncmd )
}
else if (getModelGroup() in ['TS0601_Tuya_2']) {
logDebug "battery_state (0x03) is ${fncmd}" // ['low', 'medium', 'high']
def rawValue = 0
/* groovylint-disable-next-line CouldBeSwitchStatement */
if (fncmd == 2) { rawValue = 100 } // Battery High
else if (fncmd == 1) { rawValue = 66 } // Battery Medium
else if (fncmd == 0) { rawValue = 33 } // Battery Low
getBatteryPercentageResult(rawValue * 2)
}
else { // _TZE200_zl1kmjqx link quality?
illuminanceEvent(fncmd)
}
break
case 0x04 : // battery
getBatteryPercentageResult(fncmd * 2)
if (settings?.txtEnable) { log.info "${device.displayName} battery is $fncmd %" }
break
case 0x05 : // Soil Monitor
if (fncmd > 32767) {
// not good for the plants ...
fncmd = fncmd - 65536
}
if (getModelGroup() in ['TS0601_Soil']) {
temperatureEvent( fncmd )
}
else if (getModelGroup() in ['TS0601_Soil', 'TS0601_Soil_II']) {
temperatureEvent( fncmd / 10.0 )
}
else {
if (settings?.logEnable) { log.warn "${device.displayName} Soil Monitor reported value ${fncmd}" }
}
break
case 0x09 : // temp. scale 1=Fahrenheit 0=Celsius (TS0601 Tuya and Haoze) TS0601_Tuya does not change the symbol on the LCD ! // including 'TS0601_Tuya_2'
if (settings?.logEnable) { log.info "${device.displayName} Temperature scale reported by device is: ${fncmd == 1 ? 'Fahrenheit' : 'Celsius' }" } // {'celsius' : new Enum(0), 'fahrenheit' : new Enum(1)}
break
case 0x0A : // (10) Max. Temp Alarm, Value / 10 (both TS0601_Tuya and TS0601_Haozee) // including 'TS0601_Tuya_2'
if (((safeToDouble(settings?.maxTempAlarmPar) * 10.0 as int) == (fncmd as int)) || (getModelGroup() in ['TS0601_Haozee'])) {
if (settings?.logEnable) { log.info "${device.displayName} reported temperature alarm upper limit ${fncmd / 10.0 as double} C" }
}
else {
if (settings?.logEnable) { log.warn "${device.displayName} warning: temperature alarm upper limit reported by the device (${fncmd / 10.0 as double} C) differs from the preference setting (${settings?.maxTempAlarmPar} C)" }
}
break
case 0x0B : // (11) Min. Temp Alarm, Value / 10 (both TS0601_Tuya and TS0601_Haozee) // including 'TS0601_Tuya_2'
if (((safeToDouble(settings?.minTempAlarmPar) * 10.0 as int) == (fncmd as int)) || (getModelGroup() in ['TS0601_Haozee'])) {
if (settings?.logEnable) { log.info "${device.displayName} reported temperature alarm lower limit ${fncmd / 10.0 as double} C" }
}
else {
if (settings?.logEnable) { log.warn "${device.displayName} warning: temperature alarm lower limit reported by the device (${fncmd / 10.0 as double} C) differs from the preference setting (${settings?.minTempAlarmPar} C)" }
}
break
case 0x0C : // (12) Max?. Humidity Alarm (Haozee only?)
if (settings?.logEnable) { log.info "${device.displayName} humidity alarm upper limit is ${fncmd} " }
break
case 0x0D : // (13) Min?. Humidity Alarm (Haozee only?)
if (settings?.logEnable) { log.info "${device.displayName} humidity alarm lower limit is ${fncmd} " }
//device.updateSetting("minHumidityAlarmPar", [value:fncmd, type:"number"])
break
case 0x0E : // (14) Temperature Alarm 0 = low alarm? 1 = high alarm? 2 = alarm cleared
if (getModelGroup() in ['TS0601_Soil', 'TS0601_Soil_II']) {
if (settings?.txtEnable) { log.info "${device.displayName} battery_state (0x0E) is ${fncmd}" }
}
else if (getModelGroup() in ['DS18B20']) {
logDebug "DS18B20 Restart Status is ${fncmd}"
}
else {
if (fncmd == 1) {
if (settings?.txtEnable) { log.info "${device.displayName} Minimal Temperature Alarm (0x0E=${fncmd}) is active" }
}
else if (fncmd == 0) { // TS0601_Haozee only?
if (settings?.txtEnable) { log.info "${device.displayName} Maximal Temperature Alarm (0x0E=${fncmd}) is active" }
}
else if (fncmd == 2 ) {
if (getModelGroup() in ['TS0601_Haozee']) {
if (settings?.txtEnable) { log.info "${device.displayName} Maximal Temperature Alarm (0x0E=${fncmd}) is inactive" }
}
else {
if (settings?.txtEnable) { log.info "${device.displayName} Minimal Temperature Alarm (0x0E=${fncmd}) is inactive" }
}
}
else {
if (settings?.txtEnable) { log.warn "${device.displayName} Temperature Alarm (0x0E) UNKNOWN value ${fncmd}" } // 1 if alarm (lower alarm) ? 2 if lower alam is cleared
}
}
break
case 0x0F : // (15) humidity Alarm 0 = low alarm? 1 = high alarm? 2 = alarm cleared (Haozee only?)
if (getModelGroup() in ['TS0601_Soil', 'TS0601_Soil_II']) {
getBatteryPercentageResult(fncmd * 2)
}
else {
if (fncmd == 1) { if (settings?.txtEnable) { log.info "${device.displayName} Minimal Humidity Alarm (0x0F=${fncmd}) is active" } }
else if (fncmd == 0) { if (settings?.txtEnable) { log.info "${device.displayName} Maximal Humidity Alarm (0x0F=${fncmd}) is active" } }
else if (fncmd == 2 ) { if (settings?.txtEnable) { log.info "${device.displayName} Humidity Alarm (0x0F=${fncmd}) is inactive" } }
else { if (settings?.logEnable) { log.warn "${device.displayName} Temperature Alarm (0x0E) UNKNOWN value ${fncmd}" } }// 1 if alarm (lower alarm) ? 2 if lower alam is cleared
}
break
case 0x10 : // (16) Current Luminance _TZ3000_qaaysllp
illuminanceEvent(fncmd)
break
case 0x11 : // (17) temperature max reporting interval, default 120 min (Haozee only) // maxReportingTimeTemp
if (settings?.maxReportingTimeTemp == ((fncmd * 60 / 2.5) as int)) {
if (settings?.logEnable) { log.info "${device.displayName} reported temperature max reporting interval ${((fncmd * 60 / 2.5) as int)} seconds" }
}
else {
if (settings?.logEnable) { log.warn "${device.displayName} warning: temperature max reporting interval reported by the device (${((fncmd * 60 / 2.5) as int)}s) differs from the preference setting (${settings?.maxReportingTimeTemp}s)" }
}
break
case 0x12 : // (18) humidity max reporting interval, default 120 min (Haozee only)
if (settings?.maxReportingTimeHumidity == ((fncmd * 60 / 2.5) as int)) {
if (settings?.logEnable) { log.info "${device.displayName} reported humidity max reporting interval ${((fncmd * 60 / 2.5) as int)} seconds" }
}
else {
if (settings?.logEnable) { log.warn "${device.displayName} warning: humidity max reporting interval reported by the device (${((fncmd * 60 / 2.5) as int)}s) differs from the preference setting (${settings?.maxReportingTimeHumidity}s)" }
}
break
case 0x13 : // (19) temperature sensitivity(value/2/10) default 0.3C ( divide / 2 for Haozee only) // including 'TS0601_Tuya_2'
if (getModelGroup() in ['DS18B20']) {
logDebug "DS18B20 Delay-off Schedule is ${fncmd}"
}
else {
def divider = getModelGroup() in ['TS0601_Haozee'] ? 20.0 : 10.0
if ((safeToDouble(settings?.temperatureSensitivity) * divider as int) == (fncmd as int)) {
if (settings?.logEnable) { log.info "${device.displayName} reported temperature sensitivity ${(fncmd / divider)} C" }
}
else {
if (settings?.logEnable) { log.warn "${device.displayName} warning: temperature sensitivity reported by the device (${fncmd / divider}) differs from the preference setting (${settings?.temperatureSensitivity})" }
}
}
break
case 0x14 : // (20) humidity sensitivity default 3% (Haozee only)
if (settings?.humiditySensitivity == fncmd) {
if (settings?.logEnable) { log.info "${device.displayName} reported humidity sensitivity ${fncmd} %" }
}
else {
if (settings?.logEnable) { log.warn "${device.displayName} warning: humidity sensitivity reported by the device (${fncmd}%) differs from the preference setting (${settings?.humiditySensitivity}%)" }
}
break
case 0x15 : // (21) buzer switch
if (settings?.logEnable) { log.info "${device.displayName} _TZ3000_qaaysllp buzer switch is ${fncmd} " }
break
case 0x65 : // (101)
if (getModelGroup() in ['DS18B20']) {
logDebug "DS18B20 Work Mode is ${fncmd}"
}
else {
if (settings?.logEnable) { log.warn "${device.displayName} NOT PROCESSED Tuya cmd: dp=${dp} value=${fncmd} descMap.data = ${descMap?.data}" }
}
illuminanceEventLux( safeToInt( fncmd ) ) // _TZE200_pay2byax
break
case 0x66 : // (102)
if (getModelGroup() in ['DS18B20']) {
if (fncmd > 32767) {
fncmd = fncmd - 65536
}
temperatureEvent( fncmd / 10.0 )
}
else {
logDebug "NOT PROCESSED Tuya cmd: dp=${dp} value=${fncmd} descMap.data = ${descMap?.data}"
}
break
default :
if (settings?.logEnable) { log.warn "${device.displayName} NOT PROCESSED Tuya cmd: dp=${dp} value=${fncmd} descMap.data = ${descMap?.data}" }
break
}
}
private int getTuyaAttributeValue(ArrayList _data, index) {
int retValue = 0
if (_data.size() >= 6) {
int dataLength = _data[5 + index] as Integer
int power = 1
for (i in dataLength..1) {
retValue = retValue + power * zigbee.convertHexToInt(_data[index + i + 5])
power = power * 256
}
}
return retValue
}
def getModelGroup() {
def manufacturer = device.getDataValue('manufacturer')
def modelGroup = 'UNKNOWN'
if (modelGroupPreference == null) {
device.updateSetting('modelGroupPreference', [value:'Auto detect', type:'enum'])
}
if (modelGroupPreference == 'Auto detect') {
if (manufacturer in Models) {
modelGroup = Models[manufacturer]
}
else {
modelGroup = 'UNKNOWN'
}
}
else {
modelGroup = modelGroupPreference
}
// if (settings?.logEnable) { log.trace "${device.displayName} manufacturer ${manufacturer} group is ${modelGroup}" }
return modelGroup
}
def temperatureEvent( temperaturePar, isDigital=false ) {
def temperature = temperaturePar
def map = [:]
Map statsMap = stringToJsonMap(state.stats); try { statsMap['tempCtr']++ } catch (e) { statsMap['tempCtr'] = 1 }; state.stats = mapToJsonString(statsMap)
map.name = 'temperature'
def Scale = location.temperatureScale
if (Scale == 'F') {
temperature = (temperature * 1.8) + 32
map.unit = '\u00B0' + 'F'
}
else {
map.unit = '\u00B0' + 'C'
}
def tempCorrected = temperature + safeToDouble(settings?.temperatureOffset)
map.value = Math.round((tempCorrected - 0.05) * 10) / 10
map.type = isDigital == true ? 'digital' : 'physical'
map.isStateChange = true
map.descriptionText = "${map.name} is ${tempCorrected} ${map.unit}"
Map lastRxMap = stringToJsonMap(state.lastRx)
def timeElapsed = Math.round((now() - lastRxMap['tempTime']) / 1000)
Integer timeRamaining = (minReportingTimeTemp - timeElapsed) as Integer
if (timeElapsed >= minReportingTimeTemp) {
if (settings?.txtEnable) { log.info "${device.displayName } ${map.descriptionText }" }
unschedule('sendDelayedEventTemp') //get rid of stale queued reports
lastRxMap['tempTime'] = now()
sendEvent(map)
}
else { // queue the event
map.type = 'delayed'
if (settings?.logEnable) { log.debug "${device.displayName} DELAYING ${timeRamaining} seconds event : ${map}" }
runIn(timeRamaining, 'sendDelayedEventTemp', [overwrite: true, data: map])
}
state.lastRx = mapToJsonString(lastRxMap)
}
private void sendDelayedEventTemp(Map map) {
if (settings?.txtEnable) { log.info "${device.displayName } ${map.descriptionText } (${map.type })" }
Map lastRxMap = stringToJsonMap(state.lastRx); try { lastRxMap['tempTime'] = now() } catch (e) { lastRxMap['tempTime'] = now() - (minReportingTimeTemp * 2000) }; state.lastRx = mapToJsonString(lastRxMap)
sendEvent(map)
}
def humidityEvent( humidity, isDigital=false ) {
def map = [:]
Map statsMap = stringToJsonMap(state.stats); try { statsMap['humiCtr']++ } catch (e) { statsMap['humiCtr'] = 1 }; state.stats = mapToJsonString(statsMap)
double humidityAsDouble = safeToDouble(humidity) + safeToDouble(settings?.humidityOffset)
if (humidityAsDouble <= 0.0 || humidityAsDouble > 100.0) {
logWarn "ignored invalid humidity ${humidity} (${humidityAsDouble})"
return
}
map.value = Math.round(humidityAsDouble)
map.name = 'humidity'
map.unit = '% RH'
map.type = isDigital == true ? 'digital' : 'physical'
map.isStateChange = true
map.descriptionText = "${map.name} is ${humidityAsDouble.round(1)} ${map.unit}"
Map lastRxMap = stringToJsonMap(state.lastRx)
def timeElapsed = Math.round((now() - lastRxMap['humiTime']) / 1000)
Integer timeRamaining = (minReportingTimeHumidity - timeElapsed) as Integer
if (timeElapsed >= minReportingTimeHumidity) {
if (settings?.txtEnable) { log.info "${device.displayName } ${map.descriptionText }" }
unschedule('sendDelayedEventHumi')
lastRxMap['humiTime'] = now()
sendEvent(map)
}
else { // queue the event
map.type = 'delayed'
if (settings?.logEnable) { log.debug "${device.displayName} DELAYING ${timeRamaining} seconds event : ${map}" }
runIn(timeRamaining, 'sendDelayedEventHumi', [overwrite: true, data: map])
}
state.lastRx = mapToJsonString(lastRxMap)
}
private void sendDelayedEventHumi(Map map) {
if (settings?.txtEnable) { log.info "${device.displayName} ${map.descriptionText} (${map.type})" }
//state.lastHumi = now()
Map lastRxMap = stringToJsonMap(state.lastRx); try { lastRxMap['humiTime'] = now() } catch (e) { lastRxMap['humiTime'] = now() - (minReportingTimeHumidity * 2000) }; state.lastRx = mapToJsonString(lastRxMap)
sendEvent(map)
}
def switchEvent( value ) {
def map = [:]
map.name = 'switch'
map.value = value
map.descriptionText = "${device.displayName} switch is ${value}"
if (settings?.txtEnable) { log.info "${map.descriptionText }" }
sendEvent(map)
}
def motionEvent( value ) {
def map = [:]
map.name = 'motion'
map.value = value ? 'active' : 'inactive'
map.descriptionText = "${device.displayName} motion is ${map.value}"
if (settings?.txtEnable) { log.info "${map.descriptionText }" }
sendEvent(map)
}
def illuminanceEvent( illuminance, isDigital=false ) {
Map statsMap = stringToJsonMap(state.stats); try { statsMap['illumCtr']++ } catch (e) { statsMap['illumCtr'] = 1 }; state.stats = mapToJsonString(statsMap)
def lux = illuminance > 0 ? Math.round(Math.pow(10, (illuminance / 10000))) : 0
sendEvent('name' : 'illuminance', 'value' : lux, 'type' : isDigital == true ? 'digital' : 'physical', 'unit' : 'lx')
if (settings?.txtEnable) { log.info "$device.displayName illuminance is ${lux} Lux" }
}
def illuminanceEventLux( Integer lux, isDigital=false ) {
Map statsMap = stringToJsonMap(state.stats); try { statsMap['illumCtr']++ } catch (e) { statsMap['illumCtr'] = 1 }; state.stats = mapToJsonString(statsMap)
sendEvent('name' : 'illuminance', 'value' : lux, 'type' : isDigital == true ? 'digital' : 'physical', 'unit' : 'lx')
if (settings?.txtEnable) { log.info "$device.displayName illuminance is ${lux} Lux" }
}
// called from initialize() and when installed as a new device
def installed() {
sendEvent(name: '_info', value: 'installed', isStateChange: true)
if (settings?.txtEnable) { log.info "${device.displayName} installed()..." }
unschedule()
initializeVars(fullInit = true )
}
//
def updated() {
ArrayList cmds = []
Map lastRxMap = stringToJsonMap(state.lastRx)
Map lastTxMap = stringToJsonMap(state.lastTx)
state.modelGroup = getModelGroup()
logInfo "Updating ${device.getLabel()} (${device.getName()}) model ${device.getDataValue('model')} manufacturer ${device.getDataValue('manufacturer')} modelGroupPreference = ${modelGroupPreference} (${getModelGroup()})"
logInfo "Debug logging is ${logEnable}; Description text logging is ${txtEnable}"
if (logEnable) {
runIn(86400, 'logsOff', [overwrite: true, misfire: 'ignore']) // turn off debug logging after 30 minutes
logInfo 'Debug logging will be turned off after 24 hours'
}
else {
unschedule('logsOff')
}
Integer fncmd
if (getModelGroup() in ['TS0601_Tuya', 'TS0601_Haozee', 'TS0601_Tuya_2']) {
def divider = getModelGroup() in ['TS0601_Haozee'] ? 20.0 : 10.0
Integer intValue = ((safeToDouble(settings?.temperatureSensitivity )) * divider) as int
if (settings?.logEnable) { log.trace "${device.displayName} setting temperatureSensitivity to ${(intValue as Double) / divider} C" }
cmds += sendTuyaCommand('13', DP_TYPE_VALUE, zigbee.convertToHexString(intValue as int, 8))
}
if (getModelGroup() in ['TS0601_Tuya', 'TS0601_Haozee', 'TS0201_LCZ030', 'TS0601_Tuya_2']) {
if (location.temperatureScale == 'C') { // Celsius
cmds += sendTuyaCommand('09', DP_TYPE_ENUM, '00')
if (settings?.logEnable) { log.trace "${device.displayName} setting temperature scale to Celsius: ${cmds}" }
}
else if (location.temperatureScale == 'F') { // Fahrenheit
cmds += sendTuyaCommand('09', DP_TYPE_ENUM, '01')
if (settings?.logEnable) { log.trace "${device.displayName} setting temperature scale to Fahrenheit: ${cmds}" }
}
else {
if (settings?.logEnable) { log.warn "${device.displayName} temperatureScaleParameter does NOT MATCH! (${location.temperatureScale})" }
}
}
if (getModelGroup() in ['TS0601_Tuya', 'TS0201_LCZ030']) {
fncmd = (safeToDouble( maxTempAlarmPar ) * 10) as int
if (settings?.logEnable) { log.trace "${device.displayName} setting maxTempAlarm to ${fncmd / 10.0 as double} C" }
cmds += sendTuyaCommand('0A', DP_TYPE_VALUE, zigbee.convertToHexString(fncmd as int, 8))
fncmd = (safeToDouble( minTempAlarmPar ) * 10) as int
if (settings?.logEnable) { log.trace "${device.displayName} setting minTempAlarm to ${fncmd / 10.0 as double} C" }
cmds += sendTuyaCommand('0B', DP_TYPE_VALUE, zigbee.convertToHexString(fncmd as int, 8))
}
if (getModelGroup() in ['TS0601_Haozee']) {
Integer intValue = settings?.humiditySensitivity as int
if (settings?.logEnable) { log.trace "${device.displayName} setting humiditySensitivity to ${intValue} %" }
cmds += sendTuyaCommand('14', DP_TYPE_VALUE, zigbee.convertToHexString(intValue as int, 8))
//
intValue = ((settings?.maxReportingTimeTemp * 2.5) as int) / 60
if (settings?.logEnable) { log.trace "${device.displayName} setting Temperature Max reporting time to ${(intValue / 2.5) as int} minutes" }
cmds += sendTuyaCommand('11', DP_TYPE_VALUE, zigbee.convertToHexString(intValue as int, 8))
//
intValue = ((settings?.maxReportingTimeHumidity * 2.5) as int) / 60
if (settings?.logEnable) { log.trace "${device.displayName} setting Humidity Max reporting time to ${(intValue / 2.5) as int} minutes" }
cmds += sendTuyaCommand('12', DP_TYPE_VALUE, zigbee.convertToHexString(intValue as int, 8))
/*
fncmd = safeToInt( maxHumidityAlarmPar )
if (settings?.logEnable) { log.trace "${device.displayName} changing maxHumidityAlarm to= ${fncmd}" }
cmds += sendTuyaCommand("0C", DP_TYPE_VALUE, zigbee.convertToHexString(fncmd as int, 8))
fncmd = safeToInt( minHumidityAlarmPar )
if (settings?.logEnable) { log.trace "${device.displayName} changing minHumidityAlarm to= ${fncmd}" }
cmds += sendTuyaCommand("0D", DP_TYPE_VALUE, zigbee.convertToHexString(fncmd as int, 8))
*/
}
/* groovylint-disable-next-line EmptyIfStatement */
if (getModelGroup() in ['TS0601_Haozee']) {
// TODO - write attribute 0xF001, cluster 0x400
}
if (getModelGroup() in ['OWON']) {
cmds += initializeDevice()
}
if (isConfigurableSleepyDevice()) { // ["Zigbee NON-Tuya", "TS0201_TH"]
lastTxMap.tempCfg = (settings?.minReportingTimeTemp as int).toString() + ',' + (settings?.maxReportingTimeTemp as int).toString() + ',' + ((settings?.temperatureSensitivity * 100) as int).toString()
lastTxMap.humiCfg = (settings?.minReportingTimeHumidity as int).toString() + ',' + (settings?.maxReportingTimeHumidity as int).toString() + ',' + ((settings?.humiditySensitivity * 100) as int).toString()
if (lastTxMap.tempCfg != lastRxMap.tempCfg) {
cmds += zigbee.configureReporting(0x0402, 0x0000, DataType.INT16, settings?.minReportingTimeTemp as int, settings?.maxReportingTimeTemp as int, (settings?.temperatureSensitivity * 100) as int, [:], 200)
log.info "configure temperature reporting (${lastTxMap.tempCfg}) pending ..."
lastTxMap.tempCfgOK = false
}
else {
logDebug "Temperature reporting already configured (${lastTxMap.tempCfg}), skipping ..."
lastTxMap.tempCfgOK = true
}
if (lastTxMap.humiCfg != lastRxMap.humiCfg) {
cmds += zigbee.configureReporting(0x0405, 0x0000, DataType.UINT16, settings?.minReportingTimeHumidity as int, settings?.maxReportingTimeHumidity as int, (settings?.humiditySensitivity * 100) as int, [:], 200)
log.info "configure humidity reporting (${lastTxMap.humiCfg}) pending ..."
lastTxMap.humiCfgOK = false
}
else {
logDebug "Humidity reporting already configured (${lastTxMap.humiCfg}), skipping ..."
lastTxMap.humiCfgOK = true
}
cmds += zigbee.configureReporting(0x0001, 0x0021, DataType.UINT8, 10, 14400, 0x01, [:], 200)
cmds += zigbee.reportingConfiguration(0x0402, 0x0000, [:], 250)
cmds += zigbee.reportingConfiguration(0x0405, 0x0000, [:], 250)
cmds += zigbee.reportingConfiguration(0x0001, 0x0021, [:], 250)
}
def pendingConfig = lastTxMap.tempCfgOK == true ? 0 : 1
pendingConfig += lastTxMap.humiCfgOK == true ? 0 : 1
if (isConfigurableSleepyDevice()) { // ['Zigbee NON-Tuya', 'TS0201_TH']
if (pendingConfig != 0 ) {
logInfo "pending ${pendingConfig} reporting configurations"
updateInfo("Pending ${pendingConfig} configuration(s). Wake up the device!")
lastTxMap.cfgFailure = false
}
else {
logInfo 'no changed configuration parameters to be sent to the device.'
}
// try reading the reporting configuration anyway ...
}
state.lastTx = mapToJsonString(lastTxMap)
sendZigbeeCommands( cmds )
}
def isPendingConfig() {
Map lastTxMap = stringToJsonMap(state.lastTx)
def isConfigComplete = lastTxMap.cfgFailure || (lastTxMap.tempCfgOK && lastTxMap.humiCfgOK)
return isConfigComplete ? false : true
}
// called from parse() when any packet is received from the awaken device ...
/* groovylint-disable-next-line MethodName */
def ConfigurationStateMachine() {
if (!isConfigurableSleepyDevice()) {
return
}
Map lastTxMap = stringToJsonMap(state.lastTx)
if (lastTxMap.cfgFailure == true ) {
updateInfo('configuration failure')
unschedule('configTimer')
return
}
def configState = state.configState
logDebug "ConfigurationStateMachine configState = ${configState}"
switch (configState) {
case 0 : // idle
if (isPendingConfig()) {
logDebug 'configuration pending ...'
updateInfo('sending the reporting configuration...')
lastTxMap.cfgTimer = ConfigTimer
updated()
runIn(1, 'configTimer' , [overwrite: true, misfire: 'ignore'])
configState = 1
}
else {
logWarn 'ConfigurationStateMachine called without isPendingConfig?'
unschedule('configTimer')
}
break
case 1 : // waiting 10 seconds for acknowledge from the device // TODO - process config ERRORS !!!
if (!isPendingConfig()) {
updateInfo('configured')
lastTxMap.cfgTimer = 0
configState = 0
unschedule('configTimer')
}
else if (lastTxMap.cfgTimer == null || lastTxMap.cfgTimer == 0) { // timeout
logDebug 'Timeout!'
updateInfo('Timeout!')
lastTxMap.cfgTimer = 0
unschedule('configTimer')
configState = 0 // try again next time a packet is received from the device..
}
else {
logDebug "config confirmation still pending ... lastTxMap.cfgTimer is ${lastTxMap.cfgTimer}"
}
break
default :
logWarn "ConfigurationStateMachine() unknown state ${configState}"
unschedule('configTimer')
configState = 0
break
}
state.configState = configState
state.lastTx = mapToJsonString(lastTxMap)
}
// scheduled from ConfigurationStateMachine
def configTimer() {
Map lastTxMap = stringToJsonMap(state.lastTx)
logDebug 'configTimer() callled'
if (lastTxMap.cfgTimer != null) {
/* groovylint-disable-next-line InvertedIfElse */
if (!isPendingConfig()) {
logDebug 'configuration is successful! '
ConfigurationStateMachine()
}
else {
lastTxMap.cfgTimer = lastTxMap.cfgTimer - 1
if (lastTxMap.cfgTimer >= 0 ) {
state.lastTx = mapToJsonString(lastTxMap) // flush the timer!
ConfigurationStateMachine()
runIn(1, 'configTimer' /*, [overwrite: true, misfire: "ignore"]*/)
logDebug "scheduling again configTimer = ${lastTxMap.cfgTimer}"
}
else {
logDebug 'configTimer expired! Do not restart it.'
lastTxMap.cfgFailure = true
}
}
}
else {
lastTxMap.cfgTimer = 0
}
state.lastTx = mapToJsonString(lastTxMap)
}
def pollTS0222() {
List cmds = []
cmds += zigbee.readAttribute(0x0001, 0x0021, [:], delay = 200) // Battery Percent
cmds += "he rattr 0x${device.deviceNetworkId} 0x02 0x0402 0x0000 {}" //, "delay 200",
cmds += "he rattr 0x${device.deviceNetworkId} 0x02 0x0405 0x0000 {}" //, "delay 200",
sendZigbeeCommands(cmds)
}
def refresh() {
checkDriverVersion()
if (getModelGroup() == 'TS0222') {
pollTS0222()
}
/* groovylint-disable-next-line ConstantIfExpression */
else if (true /*getModelGroup() in ['TS0201_TH']*/) {
List cmds = []
cmds += zigbee.readAttribute(0x0001, 0x0021, [:], delay = 200)
cmds += zigbee.readAttribute(0x0402, 0x0000, [:], delay = 200)
cmds += zigbee.readAttribute(0x0405, 0x0000, [:], delay = 200)
sendZigbeeCommands( cmds )
}
else {
logInfo 'refresh() is not implemented for this sleepy Zigbee device'
}
}
def ping() {
logInfo 'ping...'
scheduleCommandTimeoutCheck()
Map lastTxMap = stringToJsonMap(state.lastTx)
lastTxMap.pingTime = new Date().getTime()
state.lastTx = mapToJsonString(lastTxMap)
sendZigbeeCommands( zigbee.readAttribute(zigbee.BASIC_CLUSTER, 0x01, [:], 0) )
}
def sendRttEvent() {
def now = new Date().getTime()
Map lastTxMap = stringToJsonMap(state.lastTx)
def timeRunning = now.toInteger() - (lastTxMap.pingTime ?: '0').toInteger()
def descriptionText = "Round-trip time is ${timeRunning} (ms)"
logInfo "${descriptionText}"
sendEvent(name: 'rtt', value: timeRunning, descriptionText: descriptionText, unit: 'ms', isDigital: true)
}
private void scheduleCommandTimeoutCheck(int delay = COMMAND_TIMEOUT) {
runIn(delay, 'deviceCommandTimeout')
}
void deviceCommandTimeout() {
logWarn 'no response received (sleepy device or offline?)'
sendEvent(name: 'rtt', value: 'timeout', descriptionText: 'no response received', unit: '', isDigital: true)
}
def driverVersionAndTimeStamp() { VERSION + ' ' + TIME_STAMP }
def checkDriverVersion() {
if (state.driverVersion == null || driverVersionAndTimeStamp() != state.driverVersion) {
logInfo "updating the settings from the current driver version ${state.driverVersion} to the new version ${driverVersionAndTimeStamp()}"
scheduleDeviceHealthCheck() // version 1.4.0
initializeVars( fullInit = false )
//
if (state.rxCounter != null) { state.remove('rxCounter') }
if (state.txCounter != null) { state.remove('txCounter') }
if (state.packetID != null) { state.remove('packetID') }
if (state.lastRx == null || state.stats == null || state.lastTx == null) {
resetStats()
}
//
state.driverVersion = driverVersionAndTimeStamp()
}
}
void scheduleDeviceHealthCheck() {
Random rnd = new Random()
//schedule("1 * * * * ? *", 'deviceHealthCheck') // for quick test
schedule("${rnd.nextInt(59)} ${rnd.nextInt(59)} 1/3 * * ? *", 'deviceHealthCheck')
}
def resetStats() {
Map stats = [
date : new Date().format('yyyy-MM-dd', location.timeZone),
rxCtr : 0,
txCtr : 0,
rejoins: 0
]
Map lastRx = [
tempTime : now() - defaultMinReportingTime * 1000,
humiTime : now() - defaultMinReportingTime * 1000,
tempCfg : '-1,-1,-1',
humiCfg : '-1,-1,-1'
]
Map lastTx = [
tempCfg : '-1,-1,-1',
humiCfg : '-1,-1,-1',
tempCfgOK : false,
humiCfgOK : false,
cfgFailure : false,
cfgTimer : 0
]
state.stats = mapToJsonString( stats )
state.lastRx = mapToJsonString( lastRx )
state.lastTx = mapToJsonString( lastTx )
if (txtEnable == true) { log.info "${device.displayName} Statistics were reset. Press F5 to refresh the device page" }
}
def logInitializeRezults() {
if (settings?.txtEnable) { log.info "${device.displayName} manufacturer = ${device.getDataValue('manufacturer')} ModelGroup = ${getModelGroup()}" }
if (settings?.txtEnable) { log.info "${device.displayName} Initialization finished\r version=${VERSION} (Timestamp: ${TIME_STAMP})" }
}
// delete all Preferences
void deleteAllSettings() {
String preferencesDeleted = ''
settings.each { it ->
preferencesDeleted += "${it.key} (${it.value}), "
device.removeSetting("${it.key}")
}
logDebug "Deleted settings: ${preferencesDeleted}"
logInfo 'All settings (preferences) DELETED'
}
// delete all attributes
void deleteAllCurrentStates() {
String attributesDeleted = ''
device.properties.supportedAttributes.each { it -> attributesDeleted += "${it}, " ; device.deleteCurrentState("$it") }
logDebug "Deleted attributes: ${attributesDeleted}" ; logInfo 'All current states (attributes) DELETED'
}
// delete all State Variables
void deleteAllStates() {
String stateDeleted = ''
state.each { it -> stateDeleted += "${it.key}, " }
state.clear()
logDebug "Deleted states: ${stateDeleted}" ; logInfo 'All States DELETED'
}
void deleteAllScheduledJobs() {
unschedule() ; logInfo 'All scheduled jobs DELETED'
}
void deleteAllChildDevices() {
getChildDevices().each { child ->
log.info "${device.displayName} Deleting ${child.deviceNetworkId}"
deleteChildDevice(child.deviceNetworkId)
}
logDebug 'All child devices DELETED'
}
void loadAllDefaults() {
deleteAllSettings()
deleteAllCurrentStates()
deleteAllScheduledJobs()
deleteAllStates()
deleteAllChildDevices()
logWarn ('All Defaults Loaded! F5 to refresh')
}
// called by initialize() button
void initializeVars(boolean fullInit = true ) {
log.info "${device.displayName} InitializeVars()... fullInit = ${fullInit}"
if (fullInit == true ) {
loadAllDefaults()
resetStats()
state.driverVersion = driverVersionAndTimeStamp()
}
state.configState = 0 // reset the configuration state machine
if (fullInit == true || settings?.modelGroupPreference == null) { device.updateSetting('modelGroupPreference', [value:'Auto detect', type:'enum']) }
if (fullInit == true || settings?.logEnable == null) { device.updateSetting('logEnable', true) }
if (fullInit == true || settings?.txtEnable == null) { device.updateSetting('txtEnable', true) }
if (fullInit == true || settings?.temperatureOffset == null) { device.updateSetting('temperatureOffset', [value:0.0, type:'decimal']) }
if (fullInit == true || settings?.humidityOffset == null) { device.updateSetting('humidityOffset', [value:0.0, type:'decimal']) }
if (fullInit == true || settings?.advancedOptions == null) { device.updateSetting('advancedOptions', false) }
if (fullInit == true || settings?.temperatureSensitivity == null) { device.updateSetting('temperatureSensitivity', [value:0.5, type:'decimal']) }
if (fullInit == true || settings?.humiditySensitivity == null) { device.updateSetting('humiditySensitivity', [value:5, type:'number']) }
if (fullInit == true || settings?.illuminanceSensitivity == null) { device.updateSetting('illuminanceSensitivity', [value:12, type:'number']) }
if (fullInit == true || settings?.minTempAlarmPar == null) { device.updateSetting('minTempAlarmPar', [value:0.0, type:'decimal']) }
if (fullInit == true || settings?.maxTempAlarmPar == null) { device.updateSetting('maxTempAlarmPar', [value:39.0, type:'decimal']) }
if (fullInit == true || settings?.minHumidityAlarmPar == null) { device.updateSetting('minHumidityAlarmPar', [value:20, type:'number']) }
if (fullInit == true || settings?.maxHumidityAlarmPar == null) { device.updateSetting('maxHumidityAlarmPar', [value:60, type:'number']) }
if (fullInit == true || settings?.minReportingTimeTemp == null) { device.updateSetting('minReportingTimeTemp', [value:10, type:'number']) }
if (fullInit == true || settings?.maxReportingTimeTemp == null) { device.updateSetting('maxReportingTimeTemp', [value:3600, type:'number']) }
if (fullInit == true || settings?.minReportingTimeHumidity == null) { device.updateSetting('minReportingTimeHumidity', [value:10, type:'number']) }
if (fullInit == true || settings?.maxReportingTimeHumidity == null) { device.updateSetting('maxReportingTimeHumidity', [value:3600, type:'number']) }
if (fullInit == true || state.notPresentCounter == null) { state.notPresentCounter = 0 }
//
if (fullInit == true || state.modelGroup == null) { state.modelGroup = getModelGroup() }
//if (fullInit == true || state.lastTemp == null) state.lastTemp = now() - defaultMinReportingTime * 1000
//if (fullInit == true || state.lastHumi == null) state.lastHumi = now() - defaultMinReportingTime * 1000
sendHealthStatusEvent('unknown')
}
/**
* initializes the device
* Invoked from configure()
* @return zigbee commands
*/
def initializeDevice() {
ArrayList cmds = []
logInfo 'initializeDevice...'
if (getModelGroup() == 'OWON') { // https://github.com/Koenkk/zigbee-herdsman-converters/blob/e8750f6f2a34a3a6ae87f61e989a00964fb1107f/devices/owon.js
// It seem this device have 2 version, one using the endpoint 0x01 and one other using the endpoint 0x03
// https://github.com/dresden-elektronik/deconz-rest-plugin/issues/5738#issuecomment-1579521543
// there is a firmware bug in the OWON THS317-ET which leads to a reported temperature of 327.67?C if the real sensor temperature is near -20?C e.g. in a fridge.
cmds += ["zdo bind 0x${device.deviceNetworkId} 0x01 0x01 0x0001 {${device.zigbeeId}} {}", 'delay 200',]
cmds += ["zdo bind 0x${device.deviceNetworkId} 0x01 0x01 0x0402 {${device.zigbeeId}} {}", 'delay 200',]
cmds += ["zdo bind 0x${device.deviceNetworkId} 0x03 0x01 0x0001 {${device.zigbeeId}} {}", 'delay 200',]
cmds += ["zdo bind 0x${device.deviceNetworkId} 0x03 0x01 0x0402 {${device.zigbeeId}} {}", 'delay 200',]
cmds += zigbee.configureReporting(0x0001, 0x0021, DataType.UINT8, 60, 3600, 0x01, [:], 200)
cmds += zigbee.configureReporting(0x0402, 0x0000, DataType.INT16, 60, 300, 0x32, [:], 200) // or delta = 0x14
cmds += zigbee.reportingConfiguration(0x0001, 0x0021, [:], 250)
cmds += zigbee.reportingConfiguration(0x0402, 0x0000, [:], 250)
}
//
if (cmds == []) {
cmds = ['delay 299',]
}
return cmds
}
def tuyaBlackMagic() {
List cmds = []
cmds += zigbee.readAttribute(0x0000, [0x0004, 0x000, 0x0001, 0x0005, 0x0007, 0xfffe], [:], delay = 200) // Cluster: Basic, attributes: Man.name, ZLC ver, App ver, Model Id, Power Source, attributeReportingStatus
cmds += zigbee.writeAttribute(0x0000, 0xffde, 0x20, 0x13, [:], delay = 200) // was commented out ver 1.0.10 2022/11/10; returned back ver 1.20 01/15/2023
return cmds
}
def configure() {
if (settings?.txtEnable) { log.info "${device.displayName} configure().." }
List cmds = []
cmds += tuyaBlackMagic()
cmds += initializeDevice()
sendZigbeeCommands(cmds)
scheduleDeviceHealthCheck()
runIn(1, updated) // send the default or previously configured preference parameters during the Zigbee pairing process..
}
// NOT called when the driver is initialized as a new device, because the Initialize capability is NOT declared!
def initialize() {
log.info "${device.displayName} Initialize()..."
unschedule()
initializeVars(fullInit = true)
installed()
configure()
runIn( 3, logInitializeRezults)
}
private sendTuyaCommand(dp, dp_type, fncmd) {
ArrayList cmds = []
cmds += zigbee.command(CLUSTER_TUYA, SETDATA, [:], delay = 200, PACKET_ID + dp + dp_type + zigbee.convertToHexString((int)(fncmd.length() / 2), 4) + fncmd )
if (settings?.logEnable) { log.trace "${device.displayName} sendTuyaCommand = ${cmds}" }
return cmds
}
void sendZigbeeCommands(ArrayList cmd) {
if (settings?.logEnable) { log.trace "${device.displayName } sendZigbeeCommands(cmd=$cmd)" }
hubitat.device.HubMultiAction allActions = new hubitat.device.HubMultiAction()
cmd.each {
allActions.add(new hubitat.device.HubAction(it, hubitat.device.Protocol.ZIGBEE))
//if (state.txCounter != null) state.txCounter = state.txCounter + 1
}
Map statsMap = stringToJsonMap(state.stats); try { statsMap['txCtr']++ } catch (e) { statsMap['txCtr'] = 1 }; state.stats = mapToJsonString(statsMap)
sendHubCommand(allActions)
}
private getPACKET_ID() {
return zigbee.convertToHexString(new Random().nextInt(65536), 4)
}
private getDescriptionText(msg) {
def descriptionText = "${device.displayName} ${msg}"
if (settings?.txtEnable) { log.info "${descriptionText}" }
return descriptionText
}
def logsOff() {
log.warn "${device.displayName} debug logging disabled..."
device.updateSetting('logEnable', [value:'false', type:'bool'])
}
def getBatteryPercentageResult(rawValuePar) {
def rawValue = rawValuePar as int
logDebug "getBatteryPercentageResult: rawValue = ${rawValue} -> ${rawValue / 2}%"
def result = [:]
Map statsMap = stringToJsonMap(state.stats); try { statsMap['battCtr']++ } catch (e) { statsMap['battCtr'] = 1 }; state.stats = mapToJsonString(statsMap)
if (rawValue < 0) { rawValue = 0; logWarn "batteryPercentage rawValue corrected to ${rawValue}" }
if (rawValue > 200 ) { rawValue = 200; logWarn "batteryPercentage rawValue corrected to ${rawValue}" }
result.name = 'battery'
result.translatable = true
result.value = Math.round(rawValue / 2)
result.descriptionText = "${device.displayName} battery is ${result.value}%"
result.isStateChange = true
result.unit = '%'
result.type = 'physical'
sendEvent(result)
}
private Map getBatteryVoltageResult(rawValue) {
logDebug "getBatteryVoltageResult: volts = ${(double)rawValue / 10.0}"
Map statsMap = stringToJsonMap(state.stats); try { statsMap['battCtr']++ } catch (e) { statsMap['battCtr'] = 1 }; state.stats = mapToJsonString(statsMap)
def linkText = getLinkText(device)
def result = [:]
def volts = rawValue / 10
if (rawValue != 0 && rawValue != 255) {
def minVolts = 2.1
def maxVolts = 3.0
def pct = (volts - minVolts) / (maxVolts - minVolts)
def roundedPct = Math.round(pct * 100)
if (roundedPct <= 0) {
roundedPct = 1
}
result.value = Math.min(100, roundedPct)
result.descriptionText = "${linkText} battery is ${result.value}%"
result.name = 'battery'
result.isStateChange = true
result.type = 'physical'
result.unit = '%'
sendEvent(result)
}
else {
if (settings?.logEnable) { log.warn "${device.displayName} ignoring BatteryResult(${rawValue})" }
}
}
// called when any event was received from the Zigbee device in parse() method..
def setPresent() {
if ((device.currentValue('healthStatus') ?: 'unknown') != 'online') {
sendHealthStatusEvent('online')
logInfo 'is present'
}
state.notPresentCounter = 0
}
def deviceHealthCheck() {
state.notPresentCounter = (state.notPresentCounter ?: 0) + 1
if (state.notPresentCounter > presenceCountTreshold) {
if ((device.currentValue('healthStatus', true) ?: 'unknown') != 'offline' ) {
sendHealthStatusEvent('offline')
if (settings?.txtEnable) { log.warn "${device.displayName} is not present!" }
}
}
else {
if (logEnable) { log.debug "${device.displayName} deviceHealthCheck - online (notPresentCounter=${state.notPresentCounter})" }
}
}
def sendHealthStatusEvent(value) {
sendEvent(name: 'healthStatus', value: value, descriptionText: "${device.displayName} healthStatus set to $value")
}
String mapToJsonString( Map map) {
if (map == null || map == [:]) { return '' }
String str = JsonOutput.toJson(map)
return str
}
Map stringToJsonMap( String str) {
if (str == null) { return [:] }
def jsonSlurper = new JsonSlurper()
def map = jsonSlurper.parseText( str )
return map
}
Integer safeToInt(val, Integer defaultVal=0) {
return "${val}"?.isInteger() ? "${val}".toInteger() : defaultVal
}
Double safeToDouble(val, Double defaultVal=0.0) {
return "${val}"?.isDouble() ? "${val}".toDouble() : defaultVal
}
def logDebug(msg) {
if (settings?.logEnable) {
log.debug "${device.displayName} " + msg
}
}
def logInfo(msg) {
if (settings?.txtEnable) {
log.info "${device.displayName} " + msg
}
}
def logWarn(msg) {
if (settings?.logEnable) {
log.warn "${device.displayName} " + msg
}
}
def updateInfo(msg= ' ') {
sendEvent(name: '_info' , value: msg, isStateChange: false)
}
def zTest( dpCommand, dpValue, dpTypeString ) {
//ArrayList cmds = []
def dpType = dpTypeString == 'DP_TYPE_VALUE' ? DP_TYPE_VALUE : dpTypeString == 'DP_TYPE_BOOL' ? DP_TYPE_BOOL : dpTypeString == 'DP_TYPE_ENUM' ? DP_TYPE_ENUM : null
def dpValHex = dpTypeString == 'DP_TYPE_VALUE' ? zigbee.convertToHexString(dpValue as int, 8) : dpValue
if (settings?.logEnable) { log.warn "${device.displayName} sending TEST command=${dpCommand} value=${dpValue} ($dpValHex) type=${dpType}" }
sendZigbeeCommands( sendTuyaCommand(dpCommand, dpType, dpValHex) )
}
def test( String description) {
log.warn "parising : ${description}"
// "profileId:0104, clusterId:EF00, clusterInt:61184, sourceEndpoint:01, destinationEndpoint:01, options:0040, messageType:00, dni:B2BA, isClusterSpecific:true, isManufacturerSpecific:false, manufacturerId:0000, command:06, direction:01, data:[06, 2D, 66, 02, 00, 04, 00, 00, 01, 5A]"
parse( description)
}
// https://github.com/dresden-elektronik/deconz-rest-plugin/issues/5483