-- -- All Rights Reserved, Copyright (c) 2013, 2020, ALAXALA Networks Corp. -- -- AX-DEVICE-MIB.my axDevice group MIB file. -- AX-DEVICE-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, Integer32,IpAddress FROM SNMPv2-SMI MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP FROM SNMPv2-CONF DisplayString FROM SNMPv2-TC axMib FROM AX-SMI-MIB ; axDevice MODULE-IDENTITY LAST-UPDATED "202009240000Z" ORGANIZATION "ALAXALA Networks Corp." CONTACT-INFO "ALAXALA Networks Corp." DESCRIPTION "The MIB module for chassis information." REVISION "202009240000Z" DESCRIPTION "+Added axPhysLineLaneTable +Modified axBcuOperModeStatus (added faultRestrained) +Modified axPhysLineConnectorType (added type100GBASE-CWDM4, type100GBASE-4WDM-40)" REVISION "201903110000Z" DESCRIPTION "+Modified axPhysLineConnectorType (added type100GBASE-SR4) +Modified axPhysLineTransceiverStatus (added qsfp28-mounted, qsfp28-unmounted, unsupported-qsfp28-mounted, qsfp28-fault)" REVISION "201802130000Z" DESCRIPTION "+Modified axChassisType (added ax8304S)" REVISION "201607190000Z" DESCRIPTION "+Modified axPowerSupplyInputVoltage (added dc380V)" REVISION "201606130000Z" DESCRIPTION "+Modified axPhysLineConnectorType (added type40GBASE-SR4, type40GBASE-LR4) +Modified axPhysLineTransceiverStatus (added qsfpp-mounted, qsfpp-unmounted, unsupported-qsfpp-mounted, qsfpp-fault)" REVISION "201602030000Z" DESCRIPTION "+Modified axPhysLineConnectorType (added type10GBASE-ZR)" REVISION "201512250000Z" DESCRIPTION "+Modified axChassisType (added ax8308S)" REVISION "201410020000Z" DESCRIPTION "+Added axNifReadyLedStatus +Added axSmcTable +Added axSmcBoardTraps" REVISION "201402280000Z" DESCRIPTION "+Added axPsuBoardTable +Added axPsuBoardTraps +Modified axChassisType" REVISION "201308020000Z" DESCRIPTION "Initial release." ::= { axMib 1002 } ------------------------------------------------------------------------------- -- Object Identifiers ------------------------------------------------------------------------------- axChassis OBJECT IDENTIFIER ::= { axDevice 1 } axBcuBoard OBJECT IDENTIFIER ::= { axDevice 2 } axSfuBoard OBJECT IDENTIFIER ::= { axDevice 3 } axPruBoard OBJECT IDENTIFIER ::= { axDevice 4 } axPsuBoard OBJECT IDENTIFIER ::= { axDevice 5 } axNifBoard OBJECT IDENTIFIER ::= { axDevice 6 } axPhysLine OBJECT IDENTIFIER ::= { axDevice 7 } axInterface OBJECT IDENTIFIER ::= { axDevice 8 } axSfuBoardTraps OBJECT IDENTIFIER ::= { axSfuBoard 2 } axPruBoardTraps OBJECT IDENTIFIER ::= { axPruBoard 2 } axPsuBoardTraps OBJECT IDENTIFIER ::= { axPsuBoard 2 } axNifBoardTraps OBJECT IDENTIFIER ::= { axNifBoard 2 } axSmcBoardTraps OBJECT IDENTIFIER ::= { axNifBoard 4 } ------------------------------------------------------------------------------- -- Object Type definitions ------------------------------------------------------------------------------- -- -- axChassis -- axChassisMaxNumber OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Max number of chassis that can connect to this system." ::= {axChassis 1} axChassisTable OBJECT-TYPE SYNTAX SEQUENCE OF AxChassisEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table containing chassis information." ::= {axChassis 2} axChassisEntry OBJECT-TYPE SYNTAX AxChassisEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing specific chassis." INDEX { axChassisIndex } ::= {axChassisTable 1} AxChassisEntry ::= SEQUENCE { axChassisIndex Integer32, axChassisName DisplayString, axChassisAbbreviation DisplayString, axChassisType INTEGER, axPowerUnitNumber Integer32, axFanNumber Integer32, axBcuBoardNumber Integer32, axSfuBoardNumber Integer32, axPruBoardNumber Integer32, axPsuBoardNumber Integer32, axNifBoardNumber Integer32, axChassisSerialInformation DisplayString } axChassisIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "A Index of number to specify chassis." ::= {axChassisEntry 1} axChassisName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The product name of chassis." ::= {axChassisEntry 2} axChassisAbbreviation OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The abbreviated name of chassis." ::= {axChassisEntry 3} axChassisType OBJECT-TYPE SYNTAX INTEGER { other(1), ax8608R(3000), ax8616R(3001), ax8632R(3002), ax8608S(4000), ax8616S(4001), ax8632S(4002), ax8308S(4100), ax8304S(4103) } MAX-ACCESS read-only STATUS current DESCRIPTION "The type of chassis." ::= {axChassisEntry 4} axPowerUnitNumber OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of maximum power switches that this chassis can connect its." ::= {axChassisEntry 5} axFanNumber OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum number of fans that can connect to this chassis." ::= {axChassisEntry 6} axBcuBoardNumber OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum number of BCU that can connect to this chassis." ::= {axChassisEntry 7} axSfuBoardNumber OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum number of SFU that can connect to this chassis." ::= {axChassisEntry 8} axPruBoardNumber OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum number of PRU that can connect to this chassis." ::= {axChassisEntry 9} axPsuBoardNumber OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum number of PSU that can connect to this chassis." ::= {axChassisEntry 10} axNifBoardNumber OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum number of NIF that can connect to this chassis." ::= {axChassisEntry 11} axChassisSerialInformation OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Management information (SerialInformation) of chassis." ::= {axChassisEntry 13} -- -- axChassisSystemTable -- axChassisSystemTable OBJECT-TYPE SYNTAX SEQUENCE OF AxChassisSystemEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table containing chassis system information." ::= {axChassis 3} axChassisSystemEntry OBJECT-TYPE SYNTAX AxChassisSystemEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing specific chassis system." INDEX { axChassisIndex } ::= {axChassisSystemTable 1} AxChassisSystemEntry ::= SEQUENCE { axChassisStatus INTEGER, axPowerSupplyUnitRedundancyMode INTEGER, axFanMode INTEGER, axBcuBoardRedundancyStatus INTEGER, axTotalPowerSupplyCapacity Integer32, axPowerSupplyCapacitySourceA Integer32, axPowerSupplyCapacitySourceB Integer32, axTotalPowerAllocated Integer32, axTotalPowerAvailable Integer32, axRedundantPowerAvailable Integer32, axPowerAvailableSourceA Integer32, axPowerAvailableSourceB Integer32 } axChassisStatus OBJECT-TYPE SYNTAX INTEGER { up(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The current status of this chassis." ::= {axChassisSystemEntry 1} axPowerSupplyUnitRedundancyMode OBJECT-TYPE SYNTAX INTEGER { powerSupply(1), powerSupplyAndInputSource(2), notConfigured(99) } MAX-ACCESS read-only STATUS current DESCRIPTION "The redundancy mode of the power supply unit connected to this chassis." ::= {axChassisSystemEntry 2} axFanMode OBJECT-TYPE SYNTAX INTEGER { normal(1), cool(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The operation mode of fan unit connected to this chassis." ::= {axChassisSystemEntry 3} axBcuBoardRedundancyStatus OBJECT-TYPE SYNTAX INTEGER { simplex(1), duplex(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The BCU redundancy status." ::= {axChassisSystemEntry 4} axTotalPowerSupplyCapacity OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total power supply capacity on this chassis." ::= {axChassisSystemEntry 10} axPowerSupplyCapacitySourceA OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The power supply capacity on power source A." ::= {axChassisSystemEntry 11} axPowerSupplyCapacitySourceB OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The power supply capacity on power source B." ::= {axChassisSystemEntry 12} axTotalPowerAllocated OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The allocated total power supply on this chassis." ::= {axChassisSystemEntry 13} axTotalPowerAvailable OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total power available for additional boards on this chassis." ::= {axChassisSystemEntry 14} axRedundantPowerAvailable OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The power available in the power supply unit redundant case on this chassis." ::= {axChassisSystemEntry 15} axPowerAvailableSourceA OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The power available on power source A" ::= {axChassisSystemEntry 16} axPowerAvailableSourceB OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The power available on power source B" ::= {axChassisSystemEntry 17} -------------------------------------------------- -- Notification Type definitions -------------------------------------------------- axChassisSystemTraps OBJECT IDENTIFIER ::= { axChassisSystemTable 2 } axChassisSystemTrapsPrefix OBJECT IDENTIFIER ::= { axChassisSystemTraps 0 } axPowerRedundancyFailureTrap NOTIFICATION-TYPE OBJECTS { axChassisIndex } STATUS current DESCRIPTION "This trap indicates that the power supply unit are not redundantly mounted." ::= { axChassisSystemTrapsPrefix 1 } axPowerRedundancyRecoveryTrap NOTIFICATION-TYPE OBJECTS { axChassisIndex } STATUS current DESCRIPTION "This trap indicates that the power supply unit are redundantly mounted." ::= { axChassisSystemTrapsPrefix 2 } axPowerSupplyInsufficientTrap NOTIFICATION-TYPE OBJECTS { axChassisIndex } STATUS current DESCRIPTION "This trap indicates that the supply of power is insufficient." ::= { axChassisSystemTrapsPrefix 3 } axPowerSupplyInsufficientRecoveryTrap NOTIFICATION-TYPE OBJECTS { axChassisIndex } STATUS current DESCRIPTION "This trap indicates that the supply of power is sufficient now." ::= { axChassisSystemTrapsPrefix 4 } -- -- axPowerSupplyUnitTable -- axPowerSupplyUnitTable OBJECT-TYPE SYNTAX SEQUENCE OF AxPowerSupplyUnitEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table containing power unit information." ::= {axChassis 4} axPowerSupplyUnitEntry OBJECT-TYPE SYNTAX AxPowerSupplyUnitEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing power unit information." INDEX { axChassisIndex, axPowerSupplyUnitIndex } ::= {axPowerSupplyUnitTable 1} AxPowerSupplyUnitEntry ::= SEQUENCE { axPowerSupplyUnitIndex Integer32, axPowerSupplyName DisplayString, axPowerSupplyAbbreviation DisplayString, axPowerSupplySerialInformation DisplayString, axPowerSupplyInputVoltage INTEGER, axPowerSupplyConnectStatus INTEGER, axPowerSupplyStatus INTEGER, axPowerSupplyTotalAccumRunTime Integer32, axPowerSupplyCautionAccumRunTime Integer32, axPowerSupplyCriticalAccumRunTime Integer32, axPowerSupplyElapsedTime Integer32 } axPowerSupplyUnitIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "An Index of position number of power supply unit." ::= {axPowerSupplyUnitEntry 1} axPowerSupplyName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The product name of power supply unit." ::= {axPowerSupplyUnitEntry 2} axPowerSupplyAbbreviation OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The abbreviated name of power supply unit." ::= {axPowerSupplyUnitEntry 3} axPowerSupplySerialInformation OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The serial information of power supply unit." ::= {axPowerSupplyUnitEntry 4} axPowerSupplyInputVoltage OBJECT-TYPE SYNTAX INTEGER { ac100V120V(1), ac200V240V(2), dc48V(3), dc380V(4), unknown(99) } MAX-ACCESS read-only STATUS current DESCRIPTION "The input voltage of power supply unit." ::= {axPowerSupplyUnitEntry 5} axPowerSupplyConnectStatus OBJECT-TYPE SYNTAX INTEGER { connect(1), notconnect(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The current connection status of the power supply unit." ::= {axPowerSupplyUnitEntry 6} axPowerSupplyStatus OBJECT-TYPE SYNTAX INTEGER { active(1), fault(2), connect(3), notconnect(4), notsupport(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "The status of power supply unit." ::= {axPowerSupplyUnitEntry 7} axPowerSupplyTotalAccumRunTime OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Total operation time after operation of device begins." ::= {axPowerSupplyUnitEntry 8} axPowerSupplyCautionAccumRunTime OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Operating time of the power supply unit while the status of the inlet temperature of the device is caution or critical." ::= {axPowerSupplyUnitEntry 9} axPowerSupplyCriticalAccumRunTime OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Operating time of the power supply unit while the status of the inlet temperature of the device is critical." ::= {axPowerSupplyUnitEntry 10} axPowerSupplyElapsedTime OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Operating time after operation of device begins." ::= {axPowerSupplyUnitEntry 11} -------------------------------------------------- -- Notification Type definitions -------------------------------------------------- axPowerSupplyUnitTraps OBJECT IDENTIFIER ::= { axPowerSupplyUnitTable 2 } axPowerSupplyUnitTrapsPrefix OBJECT IDENTIFIER ::= { axPowerSupplyUnitTraps 0 } axPowerSupplyFailureTrap NOTIFICATION-TYPE OBJECTS { axChassisIndex, axPowerSupplyUnitIndex } STATUS current DESCRIPTION "This trap indicates that a fatal error was detected on the power supply unit." ::= { axPowerSupplyUnitTrapsPrefix 1 } axPowerSupplyRecoveryTrap NOTIFICATION-TYPE OBJECTS { axChassisIndex, axPowerSupplyUnitIndex } STATUS current DESCRIPTION "This trap indicates that the power supply unit becomes normal again." ::= { axPowerSupplyUnitTrapsPrefix 2 } axPowerSupplyStatusChangeTrap NOTIFICATION-TYPE OBJECTS { axChassisIndex, axPowerSupplyUnitIndex } STATUS current DESCRIPTION "This trap indicates that the status of power supply unit changed." ::= { axPowerSupplyUnitTrapsPrefix 3 } -- -- axFanUnitTable -- axFanUnitTable OBJECT-TYPE SYNTAX SEQUENCE OF AxFanUnitEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table containing fan unit information." ::= {axChassis 5} axFanUnitEntry OBJECT-TYPE SYNTAX AxFanUnitEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing fan unit information." INDEX { axChassisIndex, axFanUnitIndex } ::= {axFanUnitTable 1} AxFanUnitEntry ::= SEQUENCE { axFanUnitIndex Integer32, axFanUnitName DisplayString, axFanUnitAbbreviation DisplayString, axFanUnitSerialInformation DisplayString, axFanUnitStatus INTEGER, axFanUnitSpeed Integer32, axFanUnitTotalAccumRunTime Integer32, axFanUnitCautionAccumRunTime Integer32, axFanUnitCriticalAccumRunTime Integer32, axFanUnitElapsedTime Integer32, axFanUnitLedStatus Integer32 } axFanUnitIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "An Index of position number of fan." ::= {axFanUnitEntry 1} axFanUnitName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The product name of fan unit." ::= {axFanUnitEntry 2} axFanUnitAbbreviation OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The abbreviated name of fan unit." ::= {axFanUnitEntry 3} axFanUnitSerialInformation OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The serial information of fan unit." ::= {axFanUnitEntry 4} axFanUnitStatus OBJECT-TYPE SYNTAX INTEGER { active(1), fault(2), notconnect(3), notsupport(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "The status of fan unit." ::= {axFanUnitEntry 5} axFanUnitSpeed OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The current speed of fan unit." ::= {axFanUnitEntry 6} axFanUnitTotalAccumRunTime OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Total operation time after operation of device begins." ::= {axFanUnitEntry 8} axFanUnitCautionAccumRunTime OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Operating time of the fan unit while the status of the inlet temperature of the device is caution or critical." ::= {axFanUnitEntry 9} axFanUnitCriticalAccumRunTime OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Operating time of the fan unit while the status of the inlet temperature of the device is critical." ::= {axFanUnitEntry 10} axFanUnitElapsedTime OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Operating time after operation of device begins." ::= {axFanUnitEntry 11} axFanUnitLedStatus OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The state of STATUS LED of the fan unit." ::= {axFanUnitEntry 12} -------------------------------------------------- -- Notification Type definitions -------------------------------------------------- axAirFanUnitTraps OBJECT IDENTIFIER ::= { axFanUnitTable 2 } axAirFanUnitTrapsPrefix OBJECT IDENTIFIER ::= { axAirFanUnitTraps 0 } axAirFanUnitStopTrap NOTIFICATION-TYPE OBJECTS { axChassisIndex, axFanUnitIndex } STATUS current DESCRIPTION "This trap indicate that a fan stopped." ::= { axAirFanUnitTrapsPrefix 1 } axAirFanUnitRecoveryTrap NOTIFICATION-TYPE OBJECTS { axChassisIndex, axFanUnitIndex } STATUS current DESCRIPTION "This trap indicates that the fan unit becomes to normal." ::= { axAirFanUnitTrapsPrefix 2 } -- -- axBcuBoardTable -- axBcuBoardTable OBJECT-TYPE SYNTAX SEQUENCE OF AxBcuBoardEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The BCU information table." ::= {axBcuBoard 1} axBcuBoardEntry OBJECT-TYPE SYNTAX AxBcuBoardEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The BCU information entry." INDEX { axChassisIndex, axBcuBoardIndex } ::= {axBcuBoardTable 1} AxBcuBoardEntry ::= SEQUENCE { axBcuBoardIndex Integer32, axBcuOperLedStatus BITS, axBcuOperModeStatus BITS, axBcuActiveLedStatus BITS, axBcuSystem1LedStatus BITS, axBcuSystem2LedStatus BITS, axBcuBoardName DisplayString, axBcuBoardAbbreviation DisplayString, axBcuSoftwareVersion DisplayString, axBcuFlashTotalSize Integer32, axBcuFlashUsedSize Integer32, axBcuFlashFreeSize Integer32, axBcuTemperatureStatusNumber Integer32, axBcuSerialInformation DisplayString, axBcuTotalAccumRunTime Integer32, axBcuCautionAccumRunTime Integer32, axBcuCriticalAccumRunTime Integer32, axBcuElapsedTime Integer32 } axBcuBoardIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "The index of BCU information table." ::= {axBcuBoardEntry 1} axBcuOperLedStatus OBJECT-TYPE SYNTAX BITS { unknown(0), notconnect(1), lightOff(2), green(3), greenBlink(4), red(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "The state of BCU STATUS LED of the device." ::= {axBcuBoardEntry 2} axBcuOperModeStatus OBJECT-TYPE SYNTAX BITS { unknown(0), initialize(1), active(2), standby(3), standbyConfigrationDiscord(4), standbySoftwareVersionDiscord(5), fault(7), inactive(8), notconnect(9), notsupport(10), faultRestrained(11) } MAX-ACCESS read-only STATUS current DESCRIPTION "The state of operation status of the device." ::= {axBcuBoardEntry 3} axBcuActiveLedStatus OBJECT-TYPE SYNTAX BITS { unknown(0), notconnect(1), lightOff(2), green(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "The state of ACTIVE LED status of the device." ::= {axBcuBoardEntry 4} axBcuSystem1LedStatus OBJECT-TYPE SYNTAX BITS { unknown(0), notconnect(1), lightOff(2), green(3), greenBlink(4), red(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "The state of SYSTEM LED status of the device." ::= {axBcuBoardEntry 5} axBcuSystem2LedStatus OBJECT-TYPE SYNTAX BITS { unknown(0), notconnect(1), lightOff(2), green(3), greenBlink(4), red(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "The state of SYSTEM2 LED status of the device." ::= {axBcuBoardEntry 6} axBcuBoardName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The product name of BCU Board. If BCU Board disconnected, return 0 length DisplayString." ::= {axBcuBoardEntry 7} axBcuBoardAbbreviation OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The abbreviated name of BCU Board. If BCU Board disconnected, return 0 length DisplayString." ::= {axBcuBoardEntry 8} axBcuSoftwareVersion OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The software version of device." ::= {axBcuBoardEntry 9} axBcuFlashTotalSize OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total of filesystem use capacity and unused capacity in a built-in memory is shown." ::= {axBcuBoardEntry 20} axBcuFlashUsedSize OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The use capacity of the filesystem in a built-in memory is shown." ::= {axBcuBoardEntry 21} axBcuFlashFreeSize OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The unused capacity of the filesystem in a built-in memory is shown." ::= {axBcuBoardEntry 22} axBcuTemperatureStatusNumber OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum number of axTemperatureStatus in this chassis." ::= {axBcuBoardEntry 23} axBcuSerialInformation OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Management information (SerialInformation) of BCU board . It is set to DisplayString of length zero " ::= {axBcuBoardEntry 24} axBcuTotalAccumRunTime OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Total operation time after operation of device begins." ::= {axBcuBoardEntry 25} axBcuCautionAccumRunTime OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Operating time while the status of the inlet temperature of the device is caution or critical." ::= {axBcuBoardEntry 26} axBcuCriticalAccumRunTime OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Operating time while the status of the inlet temperature of the device is critical." ::= {axBcuBoardEntry 27} axBcuElapsedTime OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Operating time after operation of device begins.." ::= {axBcuBoardEntry 28} -------------------------------------------------- -- Notification Type definitions -------------------------------------------------- axBcuBoardTraps OBJECT IDENTIFIER ::= { axBcuBoardTable 2 } axBcuBoardTrapsPrefix OBJECT IDENTIFIER ::= { axBcuBoardTraps 0 } axStandbyUpSimplexToDuplexTrap NOTIFICATION-TYPE OBJECTS { axChassisIndex, axBcuBoardIndex } STATUS current DESCRIPTION "System status changed from simplex to duplex." ::= { axBcuBoardTrapsPrefix 1 } axStandbyDownDuplexToSimplexTrap NOTIFICATION-TYPE OBJECTS { axChassisIndex, axBcuBoardIndex } STATUS current DESCRIPTION "System status changed from duplex to simplex." ::= { axBcuBoardTrapsPrefix 2 } axBcuMemoryUsageAlarmTrap NOTIFICATION-TYPE OBJECTS { axChassisIndex, axBcuBoardIndex } STATUS current DESCRIPTION "This trap indicates available memory is fewer than lower limit." ::= { axBcuBoardTrapsPrefix 3 } axBcuMemoryUsageRecoveryTrap NOTIFICATION-TYPE OBJECTS { axChassisIndex, axBcuBoardIndex } STATUS current DESCRIPTION "This trap indicates available memory become normal." ::= { axBcuBoardTrapsPrefix 4 } -- -- axBcuTemperatureStatusTable -- axBcuTemperatureStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF AxBcuTemperatureStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The table of temperature status maintained by the environmental monitor." ::= {axBcuBoard 2} axBcuTemperatureStatusEntry OBJECT-TYPE SYNTAX AxBcuTemperatureStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing the temperature information." INDEX { axChassisIndex, axBcuBoardIndex, axBcuTemperatureStatusIndex } ::= {axBcuTemperatureStatusTable 1} AxBcuTemperatureStatusEntry ::= SEQUENCE { axBcuTemperatureStatusIndex Integer32, axBcuTemperatureStatusDescr DisplayString, axBcuTemperatureStatusValue Integer32, axBcuTemperatureThreshold Integer32, axBcuTemperatureState Integer32, axBcuTemperatureWarning Integer32, axBcuTemperatureWarningAverage Integer32, axBcuTemperatureWarningAveragePeriod Integer32 } axBcuTemperatureStatusIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "Unique index for the testpoint being instrumented. This index is for SNMP purposes only, and has no intrinsic meaning." ::= {axBcuTemperatureStatusEntry 1} axBcuTemperatureStatusDescr OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Textual description of the testpoint being instrumented. This description is a short textual label, suitable as a human-sensible identification for the rest of the information in the entry." ::= {axBcuTemperatureStatusEntry 2} axBcuTemperatureStatusValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The current measurement of the testpoint being instrumented." ::= {axBcuTemperatureStatusEntry 3} axBcuTemperatureThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The highest value that the associated instance of the object axBcuTemperatureStatusValue may obtain before an emergency shutdown of the managed device is initiated." ::= {axBcuTemperatureStatusEntry 4} axBcuTemperatureState OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The current state of the testpoint being instrumented." ::= {axBcuTemperatureStatusEntry 5} axBcuTemperatureWarning OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The temperature value to display warning message that configured by user." ::= {axBcuTemperatureStatusEntry 6} axBcuTemperatureWarningAverage OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The average temperature value to display warning message that configured by user." ::= {axBcuTemperatureStatusEntry 7} axBcuTemperatureWarningAveragePeriod OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The period for average temperature value to display warning message that configured by user." ::= {axBcuTemperatureStatusEntry 8} -------------------------------------------------- -- Notification Type definitions -------------------------------------------------- axBcuTemperatureTraps OBJECT IDENTIFIER ::= { axBcuTemperatureStatusTable 2 } axBcuTemperatureTrapsPrefix OBJECT IDENTIFIER ::= { axBcuTemperatureTraps 0 } axBcuTemperatureTrap NOTIFICATION-TYPE OBJECTS { axChassisIndex, axBcuBoardIndex, axBcuTemperatureStatusIndex, axBcuTemperatureState } STATUS current DESCRIPTION "This trap indicates a change of the temperature maintained by the environmental monitor of BCU." ::= { axBcuTemperatureTrapsPrefix 1 } -- -- axMemoryCardTable -- axMemoryCardTable OBJECT-TYPE SYNTAX SEQUENCE OF AxMemoryCardEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table containing the memory card information." ::= {axBcuBoard 3} axMemoryCardEntry OBJECT-TYPE SYNTAX AxMemoryCardEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing a memory card information." INDEX { axChassisIndex, axBcuBoardIndex, axMemoryCardIndex } ::= {axMemoryCardTable 1} AxMemoryCardEntry ::= SEQUENCE { axMemoryCardIndex Integer32, axMemoryCardConnection INTEGER, axMemoryCardID OCTET STRING, axMemoryCardTotalSize Integer32, axMemoryCardUsedSize Integer32, axMemoryCardFreeSize Integer32 } axMemoryCardIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "An Index of position number of the memory card slot." ::= {axMemoryCardEntry 1} axMemoryCardConnection OBJECT-TYPE SYNTAX INTEGER { connect(1), notconnect(2), unknown(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "The current connection status of the memory card." ::= {axMemoryCardEntry 2} axMemoryCardID OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The card identification number of the memory card." ::= {axMemoryCardEntry 3} axMemoryCardTotalSize OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total capacity of the memory card. -1 is returned if the memory card is not connected." ::= {axMemoryCardEntry 4} axMemoryCardUsedSize OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The Used capacity of the memory card. -1 is returned if the memory card is not connected." ::= {axMemoryCardEntry 5} axMemoryCardFreeSize OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The usable capacity of the memory card. -1 is returned if the memory card is not connected." ::= {axMemoryCardEntry 6} -- -- axBcuCpuTable -- axBcuCpuTable OBJECT-TYPE SYNTAX SEQUENCE OF AxBcuCpuEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table containing information of CPU equipped with BCU." ::= {axBcuBoard 4} axBcuCpuEntry OBJECT-TYPE SYNTAX AxBcuCpuEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing information of CPU equipped with BCU." INDEX { axChassisIndex, axBcuBoardIndex, axBcuCpuIndex } ::= {axBcuCpuTable 1} AxBcuCpuEntry ::= SEQUENCE { axBcuCpuIndex INTEGER, axBcuCpuStatus BITS, axBcuCpuUpTime DisplayString, axBcuCpuClock Integer32, axBcuCpuLoad1m Integer32, axBcuMemoryTotalSize Integer32, axBcuMemoryUsedSize Integer32, axBcuMemoryFreeSize Integer32, axBcuFatalErrorRestartNum Integer32 } axBcuCpuIndex OBJECT-TYPE SYNTAX INTEGER { bcucpu(1), pa(2) } MAX-ACCESS not-accessible STATUS current DESCRIPTION "An Index of type of CPU equipped with BCU." ::= {axBcuCpuEntry 1} axBcuCpuStatus OBJECT-TYPE SYNTAX BITS { unknown(0), initialize(1), active(2), fault(3), notconnect(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "The status of CPU equipped with BCU." ::= {axBcuCpuEntry 2} axBcuCpuUpTime OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Up time of BCU CPU. Format : YYYY/MM/DD hh:mm:ss zone It is set to DisplayString of length zero when BCU is disconnected." ::= {axBcuCpuEntry 3} axBcuCpuClock OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The clock speed of CPU equipped with BCU." ::= {axBcuCpuEntry 4} axBcuCpuLoad1m OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "CPU utilization equipped with BCU." ::= {axBcuCpuEntry 5} axBcuMemoryTotalSize OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The installing memory size is shown by the numerical value. If BCU Board disconnected, return -1." ::= {axBcuCpuEntry 6} axBcuMemoryUsedSize OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The used memory size is shown by the numerical value. If BCU Board disconnected, return -1." ::= {axBcuCpuEntry 7} axBcuMemoryFreeSize OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The unused memory size is shown by the numerical value. If BCU Board disconnected, return -1." ::= {axBcuCpuEntry 8} axBcuFatalErrorRestartNum OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of times the BCU has restarted automatically because of fatal error." ::= {axBcuCpuEntry 9} -- -- axLineIfTable -- axLineIfTable OBJECT-TYPE SYNTAX SEQUENCE OF AxLineIfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table containing physical port correspond to ifIndex." ::= {axInterface 1} axLineIfEntry OBJECT-TYPE SYNTAX AxLineIfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing ifIndex is assigned to physical port." INDEX { axChassisIndex, axNifBoardIndex, axPhysLineIndex, axLineIfIndex } ::= {axLineIfTable 1} AxLineIfEntry ::= SEQUENCE { axLineIfIndex Integer32, axIfIndex Integer32, axIfIpAddress IpAddress, axIfIpv6Address OCTET STRING } axLineIfIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "The value of ifIndex to distinguish entry of this table." ::= {axLineIfEntry 1} axIfIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of ifIndex which is assigned to this physical port. The value is 0 when ifIndex is not assigned to this physical port." ::= {axLineIfEntry 2} axIfIpAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "The IP address correspond to ifIndex which is assigned to this physical port. If IP address is not assigned, it is '0.0.0.0'." ::= {axLineIfEntry 3} axIfIpv6Address OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The IPv6 address correspond to ifIndex which is assigned to this physical port. If IPv6 address is not assigned,it is '00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00'." ::= {axLineIfEntry 4} ------------------------------------------------------------------------------- -- axSfuBoard ------------------------------------------------------------------------------- axSfuBoardTable OBJECT-TYPE SYNTAX SEQUENCE OF AxSfuBoardEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table containing SFU information about specific chassis." ::= {axSfuBoard 1} axSfuBoardEntry OBJECT-TYPE SYNTAX AxSfuBoardEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing SFU about specific chassis." INDEX {axChassisIndex, axSfuBoardIndex} ::= {axSfuBoardTable 1} AxSfuBoardEntry ::= SEQUENCE { axSfuBoardIndex Integer32, axSfuBoardType Integer32, axSfuOperLedStatus INTEGER, axSfuActiveLedStatus INTEGER, axSfuOperModeStatus INTEGER, axSfuUpdateStatus INTEGER, axSfuErrorRestartNum Integer32, axSfuBoardName DisplayString, axSfuBoardAbbreviation DisplayString, axSfuSerialInformation DisplayString, axSfuTemperatureState INTEGER, axSfuTotalAccumRunTime Integer32, axSfuCautionAccumRunTime Integer32, axSfuCriticalAccumRunTime Integer32, axSfuElapsedTime Integer32 } axSfuBoardIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "Position information of the SFU slots. The value is from 1 to axSfuBoardNumber." ::= {axSfuBoardEntry 1} axSfuBoardType OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "SFU ID. The value is -1 when SFU is disconnected." ::= {axSfuBoardEntry 2} axSfuOperLedStatus OBJECT-TYPE SYNTAX INTEGER { unknown(1), green(2), greenblink(3), red(4), extinction(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "The state of STATUS LED of SFU." ::= {axSfuBoardEntry 3} axSfuActiveLedStatus OBJECT-TYPE SYNTAX INTEGER { unknown(1), green(2), extinction(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "The state of ACTIVE LED of SFU." ::= {axSfuBoardEntry 4} axSfuOperModeStatus OBJECT-TYPE SYNTAX INTEGER { notconnect(1), notsupport(2), active(3), initialize(4), fault(5), inactive(6), disable(7), unknown(99) } MAX-ACCESS read-only STATUS current DESCRIPTION "Operate status on SFU. The value is 1 when SFU is disconnected." ::= {axSfuBoardEntry 5} axSfuUpdateStatus OBJECT-TYPE SYNTAX INTEGER { none(1), executing(2), restartrequired(3), failed(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "The state of an update process on SFU." ::= {axSfuBoardEntry 6} axSfuErrorRestartNum OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of times the SFU has restarted automatically because of error." ::= {axSfuBoardEntry 7} axSfuBoardName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "SFU name. It is set to DisplayString of length zero when SFU is disconnected or not supported." ::= {axSfuBoardEntry 8} axSfuBoardAbbreviation OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The abbreviation name of SFU. It is set to DisplayString of length zero when SFU is disconnected or not supported." ::= {axSfuBoardEntry 9} axSfuSerialInformation OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Management information (SerialInformation) of SFU. It is set to DisplayString of length zero when SFU is disconnected." ::= {axSfuBoardEntry 10} axSfuTemperatureState OBJECT-TYPE SYNTAX INTEGER { unknown(1), normal(2), critical(3), fault(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "The current temperature status of SFU." ::= {axSfuBoardEntry 11} axSfuTotalAccumRunTime OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Total operation time after operation of device begins." ::= {axSfuBoardEntry 12} axSfuCautionAccumRunTime OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Operating time while the status of the inlet temperature of the device is caution or critical." ::= {axSfuBoardEntry 13} axSfuCriticalAccumRunTime OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Operating time while the status of the inlet temperature of the device is critical." ::= {axSfuBoardEntry 14} axSfuElapsedTime OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Operating time after operation of the SFU begins." ::= {axSfuBoardEntry 15} -------------------------------------------------- -- Notification Type definitions -------------------------------------------------- axSfuStateChangeTrapPrefix OBJECT IDENTIFIER ::= { axSfuBoardTraps 0 } axSfuStateChangeTrap NOTIFICATION-TYPE OBJECTS { axChassisIndex, axSfuBoardIndex, axSfuOperModeStatus } STATUS current DESCRIPTION "SFU state change." ::= { axSfuStateChangeTrapPrefix 1 } ------------------------------------------------------------------------------- -- axPruBoard ------------------------------------------------------------------------------- axPruBoardTable OBJECT-TYPE SYNTAX SEQUENCE OF AxPruBoardEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table containing PRU information about specific chassis." ::= {axPruBoard 1} axPruBoardEntry OBJECT-TYPE SYNTAX AxPruBoardEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing PRU about specific chassis." INDEX {axChassisIndex, axPruBoardIndex} ::= {axPruBoardTable 1} AxPruBoardEntry ::= SEQUENCE { axPruBoardIndex Integer32, axPruBoardType Integer32, axPruOperLedStatus INTEGER, axPruOperModeStatus INTEGER, axPruUpdateStatus INTEGER, axPruErrorRestartNum Integer32, axPruBoardName DisplayString, axPruBoardAbbreviation DisplayString, axPruSerialInformation DisplayString, axPruCpuUpTime DisplayString, axPruCpuClock Integer32, axPruCpuLoad1m Integer32, axPruMemoryTotalSize Integer32, axPruMemoryUsedSize Integer32, axPruMemoryFreeSize Integer32, axPruTemperatureState INTEGER, axPruTotalAccumRunTime Integer32, axPruCautionAccumRunTime Integer32, axPruCriticalAccumRunTime Integer32, axPruElapsedTime Integer32 } axPruBoardIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "Position information of the PRU slots. The value is from 1 to axPruBoardNumber." ::= {axPruBoardEntry 1} axPruBoardType OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "PRU ID. The value is -1 when PRU is disconnected." ::= {axPruBoardEntry 2} axPruOperLedStatus OBJECT-TYPE SYNTAX INTEGER { unknown(1), green(2), greenblink(3), red(4), extinction(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "The state of STATUS LED of PRU." ::= {axPruBoardEntry 3} axPruOperModeStatus OBJECT-TYPE SYNTAX INTEGER { notconnect(1), notsupport(2), active(3), initialize(4), fault(5), inactive(6), disable(7), powershortage(8), unknown(99) } MAX-ACCESS read-only STATUS current DESCRIPTION "Operate status on PRU. The value is 1 when PRU is disconnected." ::= {axPruBoardEntry 4} axPruUpdateStatus OBJECT-TYPE SYNTAX INTEGER { none(1), executing(2), restartrequired(3), failed(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "The state of an update process on PRU." ::= {axPruBoardEntry 5} axPruErrorRestartNum OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of times the PRU has restarted automatically because of error." ::= {axPruBoardEntry 6} axPruBoardName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "PRU name. It is set to DisplayString of length zero when PRU is disconnected or not supported." ::= {axPruBoardEntry 7} axPruBoardAbbreviation OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The abbreviation name of PRU. It is set to DisplayString of length zero when PRU is disconnected or not supported." ::= {axPruBoardEntry 8} axPruSerialInformation OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Management information (SerialInformation) of PRU. It is set to DisplayString of length zero when PRU is disconnected." ::= {axPruBoardEntry 9} axPruCpuUpTime OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Up time of PRU CPU. Format : YYYY/MM/DD hh:mm:ss XXXXXXX(time zone) Time zone format : JST : JST GMT+09 : GMT + 09 hours GMT+10 : GMT + 10 hours It is set to DisplayString of length zero when PRU is disconnected or inactivated." ::= {axPruBoardEntry 10} axPruCpuClock OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "CPU clock is shown by the numerical value. If PRU disconnected, return -1." ::= {axPruBoardEntry 11} axPruCpuLoad1m OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "PRU CPU utilization of one minute is shown by the numerical value. If PRU disconnected, return -1." ::= {axPruBoardEntry 12} axPruMemoryTotalSize OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The installing memory size is shown by the numerical value. If PRU disconnected, return -1." ::= {axPruBoardEntry 13} axPruMemoryUsedSize OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The use memory size is shown by the numerical value. If PRU disconnected, return -1." ::= {axPruBoardEntry 14} axPruMemoryFreeSize OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The unused memory size is shown by the numerical value. If PRU disconnected, return -1." ::= {axPruBoardEntry 15} axPruTemperatureState OBJECT-TYPE SYNTAX INTEGER { unknown(1), normal(2), critical(3), fault(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "The current temperature status of PRU." ::= {axPruBoardEntry 16} axPruTotalAccumRunTime OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Total operation time after operation of device begins." ::= {axPruBoardEntry 17} axPruCautionAccumRunTime OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Operating time while the status of the inlet temperature of the device is caution or critical." ::= {axPruBoardEntry 18} axPruCriticalAccumRunTime OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Operating time while the status of the inlet temperature of the device is critical." ::= {axPruBoardEntry 19} axPruElapsedTime OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Operating time after operation of the PRU begins." ::= {axPruBoardEntry 20} -------------------------------------------------- -- Notification Type definitions -------------------------------------------------- axPruStateChangeTrapPrefix OBJECT IDENTIFIER ::= { axPruBoardTraps 0 } axPruStateChangeTrap NOTIFICATION-TYPE OBJECTS { axChassisIndex, axPruBoardIndex, axPruOperModeStatus } STATUS current DESCRIPTION "PRU state change." ::= { axPruStateChangeTrapPrefix 1 } ------------------------------------------------------------------------------- -- axPsuBoard ------------------------------------------------------------------------------- axPsuBoardTable OBJECT-TYPE SYNTAX SEQUENCE OF AxPsuBoardEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table containing PSU information about specific chassis." ::= {axPsuBoard 1} axPsuBoardEntry OBJECT-TYPE SYNTAX AxPsuBoardEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing PSU about specific chassis." INDEX {axChassisIndex, axPsuBoardIndex} ::= {axPsuBoardTable 1} AxPsuBoardEntry ::= SEQUENCE { axPsuBoardIndex Integer32, axPsuBoardType Integer32, axPsuOperLedStatus INTEGER, axPsuOperModeStatus INTEGER, axPsuUpdateStatus INTEGER, axPsuErrorRestartNum Integer32, axPsuBoardName DisplayString, axPsuBoardAbbreviation DisplayString, axPsuSerialInformation DisplayString, axPsuCpuUpTime DisplayString, axPsuCpuClock Integer32, axPsuCpuLoad1m Integer32, axPsuMemoryTotalSize Integer32, axPsuMemoryUsedSize Integer32, axPsuMemoryFreeSize Integer32, axPsuTemperatureState INTEGER, axPsuTotalAccumRunTime Integer32, axPsuCautionAccumRunTime Integer32, axPsuCriticalAccumRunTime Integer32, axPsuElapsedTime Integer32 } axPsuBoardIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "Position information of the PSU slots. The value is from 1 to axPsuBoardNumber." ::= {axPsuBoardEntry 1} axPsuBoardType OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "PSU ID. The value is -1 when PSU is disconnected." ::= {axPsuBoardEntry 2} axPsuOperLedStatus OBJECT-TYPE SYNTAX INTEGER { unknown(1), green(2), greenblink(3), red(4), extinction(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "The state of STATUS LED of PSU." ::= {axPsuBoardEntry 3} axPsuOperModeStatus OBJECT-TYPE SYNTAX INTEGER { notconnect(1), notsupport(2), active(3), initialize(4), fault(5), inactive(6), disable(7), powershortage(8), unknown(99) } MAX-ACCESS read-only STATUS current DESCRIPTION "Operate status on PSU. The value is 1 when PSU is disconnected." ::= {axPsuBoardEntry 4} axPsuUpdateStatus OBJECT-TYPE SYNTAX INTEGER { none(1), executing(2), restartrequired(3), failed(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "The state of an update process on PSU." ::= {axPsuBoardEntry 5} axPsuErrorRestartNum OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of times the PSU has restarted automatically because of error." ::= {axPsuBoardEntry 6} axPsuBoardName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "PSU name. It is set to DisplayString of length zero when PSU is disconnected or not supported." ::= {axPsuBoardEntry 7} axPsuBoardAbbreviation OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The abbreviation name of PSU. It is set to DisplayString of length zero when PSU is disconnected or not supported." ::= {axPsuBoardEntry 8} axPsuSerialInformation OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Management information (SerialInformation) of PSU. It is set to DisplayString of length zero when PSU is disconnected." ::= {axPsuBoardEntry 9} axPsuCpuUpTime OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Up time of PSU CPU. Format : YYYY/MM/DD hh:mm:ss XXXXXXX(time zone) Time zone format : JST : JST GMT+09 : GMT + 09 hours GMT+10 : GMT + 10 hours It is set to DisplayString of length zero when PSU is disconnected or inactivated." ::= {axPsuBoardEntry 10} axPsuCpuClock OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "CPU clock is shown by the numerical value. If PSU disconnected, return -1." ::= {axPsuBoardEntry 11} axPsuCpuLoad1m OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "PSU CPU utilization of one minute is shown by the numerical value. If PSU disconnected, return -1." ::= {axPsuBoardEntry 12} axPsuMemoryTotalSize OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The installing memory size is shown by the numerical value. If PSU disconnected, return -1." ::= {axPsuBoardEntry 13} axPsuMemoryUsedSize OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The use memory size is shown by the numerical value. If PSU disconnected, return -1." ::= {axPsuBoardEntry 14} axPsuMemoryFreeSize OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The unused memory size is shown by the numerical value. If PSU disconnected, return -1." ::= {axPsuBoardEntry 15} axPsuTemperatureState OBJECT-TYPE SYNTAX INTEGER { unknown(1), normal(2), critical(3), fault(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "The current temperature status of PSU." ::= {axPsuBoardEntry 16} axPsuTotalAccumRunTime OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Total operation time after operation of device begins." ::= {axPsuBoardEntry 17} axPsuCautionAccumRunTime OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Operating time while the status of the inlet temperature of the device is caution or critical." ::= {axPsuBoardEntry 18} axPsuCriticalAccumRunTime OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Operating time while the status of the inlet temperature of the device is critical." ::= {axPsuBoardEntry 19} axPsuElapsedTime OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Operating time after operation of the PSU begins." ::= {axPsuBoardEntry 20} -------------------------------------------------- -- Notification Type definitions -------------------------------------------------- axPsuStateChangeTrapPrefix OBJECT IDENTIFIER ::= { axPsuBoardTraps 0 } axPsuStateChangeTrap NOTIFICATION-TYPE OBJECTS { axChassisIndex, axPsuBoardIndex, axPsuOperModeStatus } STATUS current DESCRIPTION "PSU state change." ::= { axPsuStateChangeTrapPrefix 1 } ------------------------------------------------------------------------------- -- axNifBoard ------------------------------------------------------------------------------- axNifBoardTable OBJECT-TYPE SYNTAX SEQUENCE OF AxNifBoardEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table containing Network Interface cards (NIF) information that slot is loaded." ::= {axNifBoard 1} axNifBoardEntry OBJECT-TYPE SYNTAX AxNifBoardEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing NIF information about specific chassis." INDEX {axChassisIndex, axNifBoardIndex} ::= {axNifBoardTable 1} AxNifBoardEntry ::= SEQUENCE { axNifBoardIndex Integer32, axNifBoardType Integer32, axNifOperLedStatus INTEGER, axNifOperModeStatus INTEGER, axNifUpdateStatus INTEGER, axNifErrorRestartNum Integer32, axNifBoardName DisplayString, axNifBoardAbbreviation DisplayString, axNifPhysLineNumber Integer32, axNifSerialInformation DisplayString, axNifTemperatureState INTEGER, axNifTotalAccumRunTime Integer32, axNifCautionAccumRunTime Integer32, axNifCriticalAccumRunTime Integer32, axNifElapsedTime Integer32, axNifReadyLedStatus INTEGER } axNifBoardIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "Position information of NIF loading slot. The value is from 1 to axNifBoardNumber." ::= {axNifBoardEntry 1} axNifBoardType OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Type of connecting package.The value is register value of NIF package. The value is -1 when the NIF is disconnected,inactivated or disabled." ::= {axNifBoardEntry 2} axNifOperLedStatus OBJECT-TYPE SYNTAX INTEGER { unknown(1), green(2), greenblink(3), red(4), extinction(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "The state of STATUS LED of NIF." ::= {axNifBoardEntry 3} axNifOperModeStatus OBJECT-TYPE SYNTAX INTEGER { notconnect(1), notsupport(2), active(3), initialize(4), fault(5), inactive(6), disable(7), powershortage(8), unknown(99) } MAX-ACCESS read-only STATUS current DESCRIPTION "Operate status on NIF. The value is 1 when NIF is disconnected." ::= {axNifBoardEntry 4} axNifUpdateStatus OBJECT-TYPE SYNTAX INTEGER { none(1), executing(2), restartrequired(3), failed(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "The state of an update process on NIF." ::= {axNifBoardEntry 5} axNifErrorRestartNum OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of times the NIF has restarted automatically because of error." ::= {axNifBoardEntry 6} axNifBoardName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "NIF name. It is set to DisplayString of length zero when NIF is disconnected or not supported." ::= {axNifBoardEntry 7} axNifBoardAbbreviation OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The abbreviation name of NIF. It is set to DisplayString of length zero when NIF is disconnected or not supported." ::= {axNifBoardEntry 8} axNifPhysLineNumber OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of NIF's physical port.The max is 24. The value is -1 when value of axNifBoardType is -1." ::= {axNifBoardEntry 9} axNifSerialInformation OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Management information (SerialInformation) of NIF. It is set to DisplayString of length zero when NIF is disconnected." ::= {axNifBoardEntry 10} axNifTemperatureState OBJECT-TYPE SYNTAX INTEGER { unknown(1), normal(2), critical(3), fault(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "The current temperature status of NIF." ::= {axNifBoardEntry 11} axNifTotalAccumRunTime OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Total operation time after operation of device begins." ::= {axNifBoardEntry 12} axNifCautionAccumRunTime OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Operating time while the status of the inlet temperature of the device is caution or critical." ::= {axNifBoardEntry 13} axNifCriticalAccumRunTime OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Operating time while the status of the inlet temperature of the device is critical." ::= {axNifBoardEntry 14} axNifElapsedTime OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Operating time after operation of the NIF begins." ::= {axNifBoardEntry 15} axNifReadyLedStatus OBJECT-TYPE SYNTAX INTEGER { unknown(1), green(2), greenblink(3), extinction(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "The state of READY LED of NIF." ::= {axNifBoardEntry 16} axSmcTable OBJECT-TYPE SYNTAX SEQUENCE OF AxSmcEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table containing SMC information." ::= {axNifBoard 3} axSmcEntry OBJECT-TYPE SYNTAX AxSmcEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing SMC information about specific chassis." INDEX {axChassisIndex, axNifBoardIndex} ::= {axSmcTable 1} AxSmcEntry ::= SEQUENCE { axSmcCpuClock Integer32, axSmcCpuLoad1m Integer32, axSmcMemoryTotalSize Integer32, axSmcMemoryUsedSize Integer32, axSmcMemoryFreeSize Integer32 } axSmcCpuClock OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The clock speed of CPU equipped with SMC." ::= {axSmcEntry 1} axSmcCpuLoad1m OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "CPU utilization equipped with SMC." ::= {axSmcEntry 2} axSmcMemoryTotalSize OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The installing memory size is shown by the numerical value. If axNifBoardType is not SMC , return -1." ::= {axSmcEntry 3} axSmcMemoryUsedSize OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The used memory size is shown by the numerical value. If axNifBoardType is not SMC , return -1." ::= {axSmcEntry 4} axSmcMemoryFreeSize OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The unused memory size is shown by the numerical value. If axNifBoardType is not SMC , return -1." ::= {axSmcEntry 5} -------------------------------------------------- -- Notification Type definitions -------------------------------------------------- axNifStateChangeTrapPrefix OBJECT IDENTIFIER ::= { axNifBoardTraps 0 } axNifStateChangeTrap NOTIFICATION-TYPE OBJECTS { axChassisIndex, axNifBoardIndex, axNifOperModeStatus } STATUS current DESCRIPTION "NIF state change." ::= { axNifStateChangeTrapPrefix 1 } -------------------------------------------------- -- Notification Type definitions -------------------------------------------------- axSmcBoardTrapsPrefix OBJECT IDENTIFIER ::= { axSmcBoardTraps 0 } axSmcMemoryUsageAlarmTrap NOTIFICATION-TYPE OBJECTS { axChassisIndex, axNifBoardIndex } STATUS current DESCRIPTION "This trap indicates available memory is fewer than lower limit." ::= { axSmcBoardTrapsPrefix 1 } axSmcMemoryUsageRecoveryTrap NOTIFICATION-TYPE OBJECTS { axChassisIndex, axNifBoardIndex } STATUS current DESCRIPTION "This trap indicates available memory become normal." ::= { axSmcBoardTrapsPrefix 2 } ------------------------------------------------------------------------------- -- axPhysLine ------------------------------------------------------------------------------- axPhysLineTable OBJECT-TYPE SYNTAX SEQUENCE OF AxPhysLineEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table containing physical port." ::= {axPhysLine 1} axPhysLineEntry OBJECT-TYPE SYNTAX AxPhysLineEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing physical port." INDEX {axChassisIndex, axNifBoardIndex, axPhysLineIndex} ::= {axPhysLineTable 1} AxPhysLineEntry ::= SEQUENCE { axPhysLineIndex Integer32, axPhysLineConnectorType INTEGER, axPhysLineOperStatus INTEGER, axPhysLineIfIndexNumber Integer32, axPhysLineTransceiverStatus INTEGER } axPhysLineIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "Physical port number. The value is from 1 to axNifPhysLineNumber." ::= {axPhysLineEntry 1} axPhysLineConnectorType OBJECT-TYPE SYNTAX INTEGER { other(1), type1000BASE-LX(301), type1000BASE-SX(302), type1000BASE-LH(303), type1000BASE-BX10-D(304), type1000BASE-BX10-U(305), type1000BASE-BX40-D(306), type1000BASE-BX40-U(307), type1000BASE-SX2(308), type1000BASE-UTP(309), type10GBASE-SR(401), type10GBASE-LR(402), type10GBASE-ER(403), type10GBASE-ZR(404), type40GBASE-SR4(501), type40GBASE-LR4(502), type100GBASE-LR4(601), type100GBASE-SR4(602), type100GBASE-CWDM4(603), type100GBASE-4WDM-40(604) } MAX-ACCESS read-only STATUS current DESCRIPTION "Connector type is connected physical port. The value is 1(other) when connector is disconnected or connector type is unknown." ::= {axPhysLineEntry 2} axPhysLineOperStatus OBJECT-TYPE SYNTAX INTEGER { other(1), active(2), initialization(3), down(4), lock(6), close(7), line-fault(8), test(9), standby(10), suspend(11), unused(12), mismatch(13) } MAX-ACCESS read-only STATUS current DESCRIPTION "Status of physical port." ::= {axPhysLineEntry 3} axPhysLineIfIndexNumber OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of ifIndex which is included in physical port." ::= {axPhysLineEntry 4} axPhysLineTransceiverStatus OBJECT-TYPE SYNTAX INTEGER { unchangeable-transceiver(1), sfp-mounted(20), sfp-unmounted(21), unsupported-sfp-mounted(22), sfp-fault(24), sfpp-mounted(40), sfpp-unmounted(41), unsupported-sfpp-mounted(42), sfpp-fault(44), qsfpp-mounted(50), qsfpp-unmounted(51), unsupported-qsfpp-mounted(52), qsfpp-fault(54), cfp-mounted(60), cfp-unmounted(61), unsupported-cfp-mounted(62), cfp-fault(64), qsfp28-mounted(70), qsfp28-unmounted(71), unsupported-qsfp28-mounted(72), qsfp28-fault(74) } MAX-ACCESS read-only STATUS current DESCRIPTION "Type and status of replaceable transceiver." ::= {axPhysLineEntry 5} ------------------------------------------------------------------------------- -- axPhysLineLane ------------------------------------------------------------------------------- axPhysLineLaneTable OBJECT-TYPE SYNTAX SEQUENCE OF AxPhysLineLaneEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table containing lane information." ::= {axPhysLine 2} axPhysLineLaneEntry OBJECT-TYPE SYNTAX AxPhysLineLaneEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing lane information." INDEX {axChassisIndex, axNifBoardIndex, axPhysLineIndex, axPhysLineLaneIndex} ::= {axPhysLineLaneTable 1} AxPhysLineLaneEntry ::= SEQUENCE { axPhysLineLaneIndex Integer32, axPhysLineLaneTransceiverTxPower Integer32, axPhysLineLaneTransceiverRxPower Integer32 } axPhysLineLaneIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "Lane number. The value is from 1 to 4." ::= {axPhysLineLaneEntry 1} axPhysLineLaneTransceiverTxPower OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A value obtained by multiplying the transmitted optical power (dBm) by 10. The value is from -400 to 82 or 300." ::= {axPhysLineLaneEntry 2} axPhysLineLaneTransceiverRxPower OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A value obtained by multiplying the received optical power (dBm) by 10. The value is from -400 to 82 or 300." ::= {axPhysLineLaneEntry 3} -------------------------------------------------- -- Conformance Statements -------------------------------------------------- -- -- Conformance identifier -- axDeviceConformance OBJECT IDENTIFIER ::= { axDevice 1000 } axDeviceCompliances OBJECT IDENTIFIER ::= { axDeviceConformance 1 } axDeviceGroups OBJECT IDENTIFIER ::= { axDeviceConformance 2 } -- -- Compliance -- axDeviceCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "axDevice" MODULE -- this module MANDATORY-GROUPS{ axDeviceGroup, axDeviceTrapGroup } ::= { axDeviceCompliances 1 } -- -- Object Group -- axDeviceGroup OBJECT-GROUP OBJECTS { axChassisMaxNumber, axChassisName, axChassisAbbreviation, axChassisType, axPowerUnitNumber, axFanNumber, axBcuBoardNumber, axSfuBoardNumber, axPruBoardNumber, axPsuBoardNumber, axNifBoardNumber, axChassisSerialInformation, axChassisStatus, axPowerSupplyUnitRedundancyMode, axFanMode, axBcuBoardRedundancyStatus, axTotalPowerSupplyCapacity, axPowerSupplyCapacitySourceA, axPowerSupplyCapacitySourceB, axTotalPowerAllocated, axTotalPowerAvailable, axRedundantPowerAvailable, axPowerAvailableSourceA, axPowerAvailableSourceB, axPowerSupplyName, axPowerSupplyAbbreviation, axPowerSupplySerialInformation, axPowerSupplyInputVoltage, axPowerSupplyConnectStatus, axPowerSupplyStatus, axPowerSupplyTotalAccumRunTime, axPowerSupplyCautionAccumRunTime, axPowerSupplyCriticalAccumRunTime, axPowerSupplyElapsedTime, axFanUnitName, axFanUnitAbbreviation, axFanUnitSerialInformation, axFanUnitStatus, axFanUnitSpeed, axFanUnitTotalAccumRunTime, axFanUnitCautionAccumRunTime, axFanUnitCriticalAccumRunTime, axFanUnitElapsedTime, axFanUnitLedStatus, axBcuOperLedStatus, axBcuOperModeStatus, axBcuActiveLedStatus, axBcuSystem1LedStatus, axBcuSystem2LedStatus, axBcuBoardName, axBcuBoardAbbreviation, axBcuSoftwareVersion, axBcuFlashTotalSize, axBcuFlashUsedSize, axBcuFlashFreeSize, axBcuTemperatureStatusNumber, axBcuSerialInformation, axBcuTotalAccumRunTime, axBcuCautionAccumRunTime, axBcuCriticalAccumRunTime, axBcuElapsedTime, axBcuTemperatureStatusDescr, axBcuTemperatureStatusValue, axBcuTemperatureThreshold, axBcuTemperatureState, axBcuTemperatureWarning, axBcuTemperatureWarningAverage, axBcuTemperatureWarningAveragePeriod, axMemoryCardConnection, axMemoryCardID, axMemoryCardTotalSize, axMemoryCardUsedSize, axMemoryCardFreeSize, axBcuCpuStatus, axBcuCpuUpTime, axBcuCpuClock, axBcuCpuLoad1m, axBcuMemoryTotalSize, axBcuMemoryUsedSize, axBcuMemoryFreeSize, axBcuFatalErrorRestartNum, axIfIndex, axIfIpAddress, axIfIpv6Address, axSfuBoardType, axSfuOperLedStatus, axSfuActiveLedStatus, axSfuOperModeStatus, axSfuUpdateStatus, axSfuErrorRestartNum, axSfuBoardName, axSfuBoardAbbreviation, axSfuSerialInformation, axSfuTemperatureState, axSfuTotalAccumRunTime, axSfuCautionAccumRunTime, axSfuCriticalAccumRunTime, axSfuElapsedTime, axPruBoardType, axPruOperLedStatus, axPruOperModeStatus, axPruUpdateStatus, axPruErrorRestartNum, axPruBoardName, axPruBoardAbbreviation, axPruSerialInformation, axPruCpuUpTime, axPruCpuClock, axPruCpuLoad1m, axPruMemoryTotalSize, axPruMemoryUsedSize, axPruMemoryFreeSize, axPruTemperatureState, axPruTotalAccumRunTime, axPruCautionAccumRunTime, axPruCriticalAccumRunTime, axPruElapsedTime, axPsuBoardType, axPsuOperLedStatus, axPsuOperModeStatus, axPsuUpdateStatus, axPsuErrorRestartNum, axPsuBoardName, axPsuBoardAbbreviation, axPsuSerialInformation, axPsuCpuUpTime, axPsuCpuClock, axPsuCpuLoad1m, axPsuMemoryTotalSize, axPsuMemoryUsedSize, axPsuMemoryFreeSize, axPsuTemperatureState, axPsuTotalAccumRunTime, axPsuCautionAccumRunTime, axPsuCriticalAccumRunTime, axPsuElapsedTime, axNifBoardType, axNifOperLedStatus, axNifOperModeStatus, axNifUpdateStatus, axNifErrorRestartNum, axNifBoardName, axNifBoardAbbreviation, axNifPhysLineNumber, axNifSerialInformation, axNifTemperatureState, axNifTotalAccumRunTime, axNifCautionAccumRunTime, axNifCriticalAccumRunTime, axNifElapsedTime, axNifReadyLedStatus, axSmcCpuClock, axSmcCpuLoad1m, axSmcMemoryTotalSize, axSmcMemoryUsedSize, axSmcMemoryFreeSize, axPhysLineConnectorType, axPhysLineOperStatus, axPhysLineIfIndexNumber, axPhysLineTransceiverStatus, axPhysLineLaneTransceiverTxPower, axPhysLineLaneTransceiverRxPower } STATUS current DESCRIPTION "The collection of objects Device." ::= { axDeviceGroups 1 } -- -- Notification Group -- axDeviceTrapGroup NOTIFICATION-GROUP NOTIFICATIONS { axPowerRedundancyFailureTrap, axPowerRedundancyRecoveryTrap, axPowerSupplyInsufficientTrap, axPowerSupplyInsufficientRecoveryTrap, axPowerSupplyFailureTrap, axPowerSupplyRecoveryTrap, axPowerSupplyStatusChangeTrap, axAirFanUnitStopTrap, axAirFanUnitRecoveryTrap, axStandbyUpSimplexToDuplexTrap, axStandbyDownDuplexToSimplexTrap, axBcuMemoryUsageAlarmTrap, axBcuMemoryUsageRecoveryTrap, axBcuTemperatureTrap, axSfuStateChangeTrap, axPruStateChangeTrap, axPsuStateChangeTrap, axNifStateChangeTrap, axSmcMemoryUsageAlarmTrap, axSmcMemoryUsageRecoveryTrap } STATUS current DESCRIPTION "The collection of notifications of Device." ::= { axDeviceGroups 10 } END