PACKETFLUX-SENSORS-MIB DEFINITIONS ::= BEGIN IMPORTS packetfluxFeatureSpecific FROM PACKETFLUX-SMI Fixed2DecimalDigits, Fixed6DecimalDigits FROM PACKETFLUX-TC OBJECT-GROUP FROM SNMPv2-CONF MODULE-IDENTITY, OBJECT-IDENTITY, OBJECT-TYPE, Unsigned32 FROM SNMPv2-SMI DisplayString, TEXTUAL-CONVENTION FROM SNMPv2-TC ; packetfluxSensors MODULE-IDENTITY LAST-UPDATED "202004120559Z" -- April 12, 2020 ORGANIZATION "PacketFlux Technologies" CONTACT-INFO "custsvc@packetflux.com http://www.packetflux.com" DESCRIPTION "MIB for generic sensor types found throughout a system" REVISION "202004120559Z" -- April 12, 2020 DESCRIPTION "Added additional functions implemented initially in the SiteMonitor Base 3, including a separate Sensor Function column on each Sensor Type, and addition of the resistanceSensor sensor type" REVISION "201807081126Z" -- July 08, 2018 DESCRIPTION "Initial version of the mib" ::= { packetfluxFeatureSpecific 2 } voltageSensorTable OBJECT-TYPE SYNTAX SEQUENCE OF VoltageSensorEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Sensors which read voltage with units of 'volts'." ::= { packetfluxSensors 1 } voltageSensorEntry OBJECT-TYPE SYNTAX VoltageSensorEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A single entry of the voltageSensor table." INDEX { voltageSensorSlot, voltageSensorIndex } ::= { voltageSensorTable 1 } VoltageSensorEntry ::= SEQUENCE { voltageSensorSlot Unsigned32, voltageSensorIndex Unsigned32, voltageSensorDescription DisplayString, voltageSensorValue Fixed6DecimalDigits, voltageSensorFunction DisplayString } voltageSensorSlot OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "The slot which contains the sensor." ::= { voltageSensorEntry 1 } voltageSensorIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "The number of the sensor within the slot. This field distinguishes between multiple sensors of the same type in the same slot, and is used as an index for this table." ::= { voltageSensorEntry 2 } voltageSensorDescription OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Contains a brief description for this sensor. This description may be able to be changed by the user." ::= { voltageSensorEntry 3 } voltageSensorValue OBJECT-TYPE SYNTAX Fixed6DecimalDigits UNITS "V" MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the sensor in volts. Note that this is reported from the controller with 6 fixed decimal digits which is enough to correctly represent mV and uV ranges. Some SNMP tools will automatically put the decimal in the right spot. If not, you will need to divide this value by 1,000,000 to get the value in Volts." ::= { voltageSensorEntry 4 } voltageSensorFunction OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "A human readable description of the function of this sensor." ::= { voltageSensorEntry 5 } currentSensorTable OBJECT-TYPE SYNTAX SEQUENCE OF CurrentSensorEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Sensors which read current with units of 'amps'." ::= { packetfluxSensors 2 } currentSensorEntry OBJECT-TYPE SYNTAX CurrentSensorEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A single entry of the currentSensor table." INDEX { currentSensorSlot, currentSensorIndex } ::= { currentSensorTable 1 } CurrentSensorEntry ::= SEQUENCE { currentSensorSlot Unsigned32, currentSensorIndex Unsigned32, currentSensorDescription DisplayString, currentSensorValue Fixed6DecimalDigits, currentSensorFunction DisplayString } currentSensorSlot OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "The slot which contains the sensor." ::= { currentSensorEntry 1 } currentSensorIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "The number of the sensor within the slot. This field distinguishes between multiple sensors of the same type in the same slot, and is used as an index for this table." ::= { currentSensorEntry 2 } currentSensorDescription OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Contains a brief description for this sensor. This may be able to be set by the user." ::= { currentSensorEntry 3 } currentSensorValue OBJECT-TYPE SYNTAX Fixed6DecimalDigits UNITS "A" MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the sensor in anps. Note that this is reported from the controller with 6 fixed decimal digits which is enough to correctly represent mA and uA ranges. Some SNMP tools will automatically put the decimal in the right spot. If not, you will need to divide this value by 1,000,000 to get the value in Amps." ::= { currentSensorEntry 4 } currentSensorFunction OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "A human readable description of the function of this sensor." ::= { currentSensorEntry 5 } temperatureSensorTable OBJECT-TYPE SYNTAX SEQUENCE OF TemperatureSensorEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Sensors which read temperature with units of degrees Celsius." ::= { packetfluxSensors 3 } temperatureSensorEntry OBJECT-TYPE SYNTAX TemperatureSensorEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A single entry of the temperatureSensor table." INDEX { temperatureSensorSlot, temperatureSensorIndex } ::= { temperatureSensorTable 1 } TemperatureSensorEntry ::= SEQUENCE { temperatureSensorSlot Unsigned32, temperatureSensorIndex Unsigned32, temperatureSensorDescription DisplayString, temperatureSensorValue Fixed2DecimalDigits, temperatureSensorFunction DisplayString } temperatureSensorSlot OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "The slot which contains the sensor." ::= { temperatureSensorEntry 1 } temperatureSensorIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "The number of the sensor within the slot. This field distinguishes between multiple sensors of the same type in the same slot, and is used as an index for this table." ::= { temperatureSensorEntry 2 } temperatureSensorDescription OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Contains a brief description for this sensor. This may be able to be set by the user." ::= { temperatureSensorEntry 3 } temperatureSensorValue OBJECT-TYPE SYNTAX Fixed2DecimalDigits UNITS "C" MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the sensor in degrees Celsius. Note that this is reported from the controller with 2 decimal digits. Some SNMP tools will automatically put the decimal in the right spot. If not, you will need to divide this value by 100 to get the value in Degrees. If you're needing Fahrenheit, multiply this value by 1.8 then add 32 - or alternatively multiply by 9, divide by 5, then add 32 to the result." ::= { temperatureSensorEntry 4 } temperatureSensorFunction OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "A human readable description of the function of this sensor." ::= { temperatureSensorEntry 5 } resistanceSensorTable OBJECT-TYPE SYNTAX SEQUENCE OF ResistanceSensorEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Sensors which read resistance with units of ohms" ::= { packetfluxSensors 4 } resistanceSensorEntry OBJECT-TYPE SYNTAX ResistanceSensorEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A single entry of the resistanceSensor table." INDEX { resistanceSensorSlot, resistanceSensorIndex } ::= { resistanceSensorTable 1 } ResistanceSensorEntry ::= SEQUENCE { resistanceSensorSlot Unsigned32, resistanceSensorIndex Unsigned32, resistanceSensorDescription DisplayString, resistanceSensorValue Fixed2DecimalDigits, resistanceSensorFunction DisplayString } resistanceSensorSlot OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "The slot which contains the sensor." ::= { resistanceSensorEntry 1 } resistanceSensorIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "The number of the sensor within the slot. This field distinguishes between multiple sensors of the same type in the same slot, and is used as an index for this table." ::= { resistanceSensorEntry 2 } resistanceSensorDescription OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Contains a brief description for this sensor. This may be able to be set by the user." ::= { resistanceSensorEntry 3 } resistanceSensorValue OBJECT-TYPE SYNTAX Fixed2DecimalDigits UNITS "C" MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the sensor in ohms. Note that this is reported from the controller with 2 decimal digits. Some SNMP tools will automatically put the decimal in the right spot. If not, you will need to divide this value by 100 to get the correct value." ::= { resistanceSensorEntry 4 } resistanceSensorFunction OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "A human readable description of the function of this sensor." ::= { resistanceSensorEntry 5 } packetfluxSensorsConformance OBJECT IDENTIFIER ::= { packetfluxSensors 128 } packetfluxSensorsGroups OBJECT IDENTIFIER ::= { packetfluxSensorsConformance 1 } packetfluxSensorsMibAllObjects OBJECT-GROUP OBJECTS { currentSensorDescription, currentSensorFunction, currentSensorValue, temperatureSensorDescription, temperatureSensorFunction, temperatureSensorValue, resistanceSensorDescription, resistanceSensorFunction, resistanceSensorValue, voltageSensorDescription, voltageSensorFunction, voltageSensorValue } STATUS current DESCRIPTION "This automatically created object group contains all those objects that do not belong to any other OBJECT-GROUP" ::= { packetfluxSensorsGroups 1 } END