--- name: Controlplan description: Generate AIAG-format Control Plans linked to PFMEAs with proper inspection methods, frequencies, and reaction plans. Supports Prototype/Pre-launch/Production phases. USE WHEN user says 'control plan', 'CP', 'inspection plan', 'process control', 'sampling frequency', 'reaction plan', or 'special characteristics'. Integrates with PFMEA, AutomotiveManufacturing, and MSA skills. --- # Control Plan ## When to Activate This Skill - "Create a control plan for [part/process]" - "What inspection frequency for [characteristic]?" - "Define control methods for [operation]" - "Link PFMEA to control plan" - "What's the reaction plan for [out-of-spec condition]?" - "Develop prototype/pre-launch/production control plan" ## Control Plan Phases ### Prototype Control Plan - **Purpose**: Control during prototype build - **Focus**: Dimensional measurements, material tests, performance - **Frequency**: Often 100% on critical dimensions - **Duration**: Until prototype approval ### Pre-Launch Control Plan - **Purpose**: Control during PPAP/validation runs - **Focus**: Enhanced inspection, process validation - **Frequency**: Increased sampling, SPC establishment - **Duration**: Until production approval (PSW) ### Production Control Plan - **Purpose**: Ongoing production control - **Focus**: Standardized controls, sustained quality - **Frequency**: Based on process capability - **Duration**: Life of production ## AIAG Control Plan Format ### Required Columns | Column | Description | Source | |--------|-------------|--------| | Part/Process Number | Operation step number | Process Flow | | Process Name/Description | Operation description | Process Flow | | Machine/Device/Jig/Tool | Equipment used | Process documentation | | Characteristic Number | Unique ID for characteristic | Sequential | | Product Characteristic | Part feature being controlled | Drawing, spec | | Process Characteristic | Process parameter affecting product | PFMEA | | Special Char Class | CC, SC, or blank | PFMEA/Drawing | | Product/Process Spec | Tolerance or requirement | Drawing, spec | | Evaluation/Measurement | Gage/method used | MSA | | Sample Size | Quantity inspected | Based on risk | | Sample Frequency | How often inspection occurs | Based on risk | | Control Method | How results are recorded/used | SPC, checklist, etc. | | Reaction Plan | Action when out of spec | Defined response | ## Special Characteristics ### Critical Characteristics (CC) - **Symbol**: Shield, (CC), or inverted delta - **Criteria**: Safety or regulatory compliance - **Requirements**: - Documented in Control Plan - Enhanced inspection (often 100%) - SPC required (Cpk ≥1.67) - Traceable records - Identified on drawing ### Significant Characteristics (SC) - **Symbol**: Diamond, (SC) - **Criteria**: Fit, function, appearance significant to customer - **Requirements**: - Documented in Control Plan - Appropriate inspection frequency - SPC recommended (Cpk ≥1.33) - Records maintained ### Standard Characteristics - **Symbol**: None - **Criteria**: All other characteristics - **Requirements**: - Documented in Control Plan - Sampling based on risk - Records as required ## Sample Size and Frequency Guidelines ### Based on Severity (from PFMEA) | Severity | Sample Size | Frequency | Rationale | |----------|-------------|-----------|-----------| | 9-10 (Safety) | 100% | Every piece | Safety critical - no escape | | 7-8 (High) | 100% or n≥5 | Per hour or per lot | High customer impact | | 5-6 (Moderate) | n≥3 | Per shift or per setup | Moderate risk | | 1-4 (Low) | n≥1 | Per lot or periodic | Low risk | ### Based on Process Capability | Cpk Range | Typical Frequency | Notes | |-----------|-------------------|-------| | <1.00 | 100% or very frequent | Process not capable | | 1.00-1.33 | Every hour or more | Marginal capability | | 1.33-1.67 | Per shift or setup | Capable | | >1.67 | Per setup, daily, or lot | Highly capable | ### Standard Frequency Terms | Term | Meaning | When to Use | |------|---------|-------------| | Continuous | 100% inspection | Safety, high risk | | Per piece | Every part | Critical characteristics | | Per hour | n pieces every hour | SPC, high-risk | | Per shift | Start and end of shift | Setup-sensitive | | Per setup | At setup only | Stable characteristics | | Per lot | One sample per production lot | Low-risk, stable | | Daily | Once per day | Periodic verification | | Weekly | Once per week | Very stable | ## Control Methods ### Inspection Methods | Method | Description | Typical Use | |--------|-------------|-------------| | Visual | Operator observation | Surface defects, presence | | Go/No-Go Gage | Attribute check | Hole size, thread, profile | | Caliper/Micrometer | Variable measurement | Dimensions | | CMM | Coordinate measurement | Complex features | | Height Gage | Surface plate measurement | Flatness, position | | Profilometer | Surface finish | Ra, Rz | | Hardness Tester | Material property | HRC, HRB | | Torque Wrench | Fastener torque | Assembly | | Leak Test | Seal integrity | Fluid systems | | Functional Test | Performance verification | End-of-line | ### Recording Methods | Method | Description | When to Use | |--------|-------------|-------------| | Check Sheet | Attribute recording | Visual checks, presence | | Data Log | Variable data recording | Measurements | | SPC Chart | Statistical control chart | Critical/significant | | Traveler | Part-specific record | Traceability | | Electronic | MES/database entry | High volume | | None (process control) | Poka-yoke, automated | Error-proofed | ## Reaction Plans ### Standard Reaction Plan Format ``` IF [out-of-spec condition] THEN: 1. STOP - Halt production/segregate suspect 2. CONTAIN - Quarantine affected parts 3. NOTIFY - Alert supervisor/quality 4. EVALUATE - Determine root cause and extent 5. CORRECT - Implement fix before restart 6. VERIFY - Confirm correction effective ``` ### Reaction Plan Examples **Dimension Out of Spec:** 1. Stop production 2. Segregate last good part to current 3. Notify Quality/Supervisor 4. Check tool condition, offset, fixture 5. Adjust/replace as needed 6. Run first piece, verify to spec 7. Inspect segregated parts 100% **Visual Defect:** 1. Reject defective part 2. Assess severity (isolated vs trend) 3. If trend: notify supervisor, review process 4. Identify root cause (tool, material, handling) 5. Implement correction 6. Resume with enhanced attention **SPC Out of Control:** 1. Mark control chart 2. Continue production if within spec 3. Investigate pattern (rule violated) 4. Identify assignable cause 5. Implement correction 6. Document on chart ## PFMEA to Control Plan Linkage ### Required Flow ``` PFMEA Item → Control Plan Entry ───────────────── ─────────────────── Process Step → Part/Process Number Function → Characteristic Failure Mode → What we're preventing Detection Control → Control Method S/O/D Ratings → Sample Size/Frequency Special Char → Special Char Class ``` ### Linkage Verification For each Control Plan line, verify: - [ ] PFMEA has corresponding failure mode - [ ] Special characteristics match - [ ] Control method addresses PFMEA detection - [ ] Frequency appropriate for risk level - [ ] Reaction plan defined ## Output Format When generating Control Plan content: ```markdown # Control Plan **Part Number**: [P/N] **Part Name**: [Description] **Customer**: [Customer Name] **Control Plan Number**: CP-[DEPT]-[SEQ] **Phase**: [ ] Prototype [ ] Pre-Launch [X] Production **Revision**: [Rev] | **Date**: [YYYY-MM-DD] **PFMEA Reference**: PFMEA-[XXX] ## Operation: [Number] - [Name] ### Characteristic 1: [Description] | Field | Value | |-------|-------| | **Char No.** | [Unique ID] | | **Product/Process** | Product / Process | | **Class** | CC / SC / - | | **Specification** | [Nominal ± Tolerance] | | **Evaluation Method** | [Gage/Equipment] | | **Sample Size** | [n] | | **Sample Frequency** | [When] | | **Control Method** | [Recording method] | | **Reaction Plan** | [Reference or inline] | ``` ## Integration with Related Skills ### PFMEA Control Plan is direct output of PFMEA: - Every PFMEA detection control → Control Plan method - PFMEA severity drives inspection frequency - PFMEA updates trigger Control Plan review **Load:** `read ~/.claude/skills/Pfmea/SKILL.md` ### MSA All gages in Control Plan require MSA: - Gage R&R for variable gages - Attribute agreement for attribute gages - MSA acceptance before production approval **Load:** `read ~/.claude/skills/Msa/SKILL.md` ### AutomotiveManufacturing Work instructions must reflect Control Plan: - Inspection steps in work instructions - Operator-level control methods - Quality checkpoints documented **Load:** `read ~/.claude/skills/Automotivemanufacturing/SKILL.md` ## Supplementary Resources For detailed guidance: `read ~/.claude/skills/Controlplan/CLAUDE.md` For templates: `read ~/.claude/skills/Controlplan/templates/control-plan-template.md` For control method selection: `read ~/.claude/skills/Controlplan/reference/control-methods.md` For sampling guidelines: `read ~/.claude/skills/Controlplan/reference/sample-frequencies.md`