# Logarex LK11 Drehstromzähler, LK13 Wechselstromzähler UART configuration: 9600 Baud, 7E1 This device has an optical D0 interface at the front. To enable the output of complete data records (full resolution and all available values), the ```INF``` parameter has to be set to ```on```. ## Example ```yaml external_components: - source: github://mampfes/esphome_obis_d0 uart: id: my_uart rx_pin: GPIO16 baud_rate: 9600 data_bits: 7 parity: EVEN stop_bits: 1 obis_d0: id: my_sm uart_id: my_uart sensor: - !include common/sensor/wifi.yaml - !include common/sensor/uptime.yaml - platform: obis_d0 name: "Consumed Energy" obis_d0_id: my_sm obis_code: "1-0:1.8.0*255" unit_of_measurement: kWh accuracy_decimals: 4 state_class: total_increasing device_class: energy value_regex: "\\d{6}\\.\\d{4}\\*kWh" # - platform: obis_d0 # name: "Consumed Energy Tariff 1" # obis_d0_id: my_sm # obis_code: "1-0:1.8.1*255" # unit_of_measurement: kWh # accuracy_decimals: 4 # state_class: total_increasing # device_class: energy # value_regex: "\\d{6}\\.\\d{4}\\*kWh" # - platform: obis_d0 # name: "Consumed Energy Tariff 2" # obis_d0_id: my_sm # obis_code: "1-0:1.8.2*255" # unit_of_measurement: kWh # accuracy_decimals: 4 # state_class: total_increasing # device_class: energy # value_regex: "\\d{6}\\.\\d{4}\\*kWh" - platform: obis_d0 name: "Provided Energy" obis_d0_id: my_sm obis_code: "1-0:2.8.0*255" unit_of_measurement: kWh accuracy_decimals: 4 state_class: total_increasing device_class: energy value_regex: "\\d{6}\\.\\d{4}\\*kWh" - platform: obis_d0 name: "Power" obis_d0_id: my_sm obis_code: "1-0:16.7.0*255" unit_of_measurement: W accuracy_decimals: 0 state_class: measurement device_class: power value_regex: "-?\\d{6}\\*W" - platform: obis_d0 name: "Voltage L1" obis_d0_id: my_sm obis_code: "1-0:32.7.0*255" unit_of_measurement: V accuracy_decimals: 1 state_class: measurement device_class: voltage value_regex: "\\d{3}\\.\\d{1}\\*V" - platform: obis_d0 name: "Voltage L2" obis_d0_id: my_sm obis_code: "1-0:52.7.0*255" unit_of_measurement: V accuracy_decimals: 1 state_class: measurement device_class: voltage value_regex: "\\d{3}\\.\\d{1}\\*V" - platform: obis_d0 name: "Voltage L3" obis_d0_id: my_sm obis_code: "1-0:72.7.0*255" unit_of_measurement: V accuracy_decimals: 1 state_class: measurement device_class: voltage value_regex: "\\d{3}\\.\\d{1}\\*V" - platform: obis_d0 name: "Current L1" obis_d0_id: my_sm obis_code: "1-0:31.7.0*255" unit_of_measurement: A accuracy_decimals: 2 state_class: measurement device_class: current value_regex: "-?\\d{3}\\.\\d{2}\\*A" - platform: obis_d0 name: "Current L2" obis_d0_id: my_sm obis_code: "1-0:51.7.0*255" unit_of_measurement: A accuracy_decimals: 2 state_class: measurement device_class: current value_regex: "-?\\d{3}\\.\\d{2}\\*A" - platform: obis_d0 name: "Current L3" obis_d0_id: my_sm obis_code: "1-0:71.7.0*255" unit_of_measurement: A accuracy_decimals: 2 state_class: measurement device_class: current value_regex: "-?\\d{3}\\.\\d{2}\\*A" - platform: obis_d0 name: "Phase Angle UL2-UL1" obis_d0_id: my_sm obis_code: "1-0:81.7.1*255" unit_of_measurement: ° accuracy_decimals: 0 state_class: measurement value_regex: "\\d{3}\\*deg" - platform: obis_d0 name: "Phase Angle UL3-UL1" obis_d0_id: my_sm obis_code: "1-0:81.7.2*255" unit_of_measurement: ° accuracy_decimals: 0 state_class: measurement value_regex: "\\d{3}\\*deg" - platform: obis_d0 name: "Phase Angle IL1-UL1" obis_d0_id: my_sm obis_code: "1-0:81.7.4*255" unit_of_measurement: ° accuracy_decimals: 0 state_class: measurement value_regex: "\\d{3}\\*deg" - platform: obis_d0 name: "Phase Angle IL2-UL2" obis_d0_id: my_sm obis_code: "1-0:81.7.15*255" unit_of_measurement: ° accuracy_decimals: 0 state_class: measurement value_regex: "\\d{3}\\*deg" - platform: obis_d0 name: "Phase Angle IL3-UL3" obis_d0_id: my_sm obis_code: "1-0:81.7.26*255" unit_of_measurement: ° accuracy_decimals: 0 state_class: measurement value_regex: "\\d{3}\\*deg" - platform: obis_d0 name: "Power Frequency" obis_d0_id: my_sm obis_code: "1-0:14.7.0*255" unit_of_measurement: Hz accuracy_decimals: 1 state_class: measurement device_class: frequency value_regex: "\\d{2}\\.\\d{1}\\*Hz" - platform: obis_d0 name: "Consumed Power last 1d" obis_d0_id: my_sm obis_code: "1-0:1.8.0*96" unit_of_measurement: kWh accuracy_decimals: 1 state_class: measurement device_class: energy value_regex: "\\d{5}\\.\\d{1}\\*kWh" - platform: obis_d0 name: "Consumed Power last 7d" obis_d0_id: my_sm obis_code: "1-0:1.8.0*97" unit_of_measurement: kWh accuracy_decimals: 1 state_class: measurement device_class: energy value_regex: "\\d{5}\\.\\d{1}\\*kWh" - platform: obis_d0 name: "Consumed Power last 30d" obis_d0_id: my_sm obis_code: "1-0:1.8.0*98" unit_of_measurement: kWh accuracy_decimals: 1 state_class: measurement device_class: energy value_regex: "\\d{5}\\.\\d{1}\\*kWh" - platform: obis_d0 name: "Consumed Power last 365d" obis_d0_id: my_sm obis_code: "1-0:1.8.0*99" unit_of_measurement: kWh accuracy_decimals: 1 state_class: measurement device_class: energy value_regex: "\\d{5}\\.\\d{1}\\*kWh" - platform: obis_d0 name: "Consumed Power last reset" obis_d0_id: my_sm obis_code: "1-0:1.8.0*100" unit_of_measurement: kWh accuracy_decimals: 1 state_class: measurement device_class: energy value_regex: "\\d{5}\\.\\d{1}\\*kWh" - platform: obis_d0 name: "CRC" obis_d0_id: my_sm obis_code: "1-0:96.90.2*255" value_regex: "[0-9a-fA-F]{4}" format: hex - platform: obis_d0 name: "Status" obis_d0_id: my_sm obis_code: "1-0:97.97.0*255" value_regex: "[0-9a-fA-F]{8}" format: hex text_sensor: - platform: obis_d0 name: "Firmware Version" obis_d0_id: my_sm obis_code: "1-0:0.2.0*255" entity_category: diagnostic value_regex: "[0-9a-fA-F.,]{20}" - platform: obis_d0 name: "Device Identification" obis_d0_id: my_sm obis_code: "1-0:96.1.0*255" entity_category: diagnostic value_regex: "\\w{16}" ```