-- -- RADWIN Management Information Base (MIB) -- Generated 11/09/22 15:20:39 Version: 11.0.78_b0047 -- RADWIN-MIB-WINLINK1000 DEFINITIONS ::= BEGIN IMPORTS enterprises, IpAddress, Counter, Gauge, TimeTicks FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212 DisplayString, ifIndex FROM RFC1213-MIB TRAP-TYPE FROM RFC-1215; radwin OBJECT IDENTIFIER ::= { enterprises 4458 } winlink1000 OBJECT IDENTIFIER ::= { radwin 1000 } -- ########################################################### -- ODU -- ########################################################### winlink1000Odu OBJECT IDENTIFIER ::= { winlink1000 1 } -- ########################################################### -- ODU Admin -- ########################################################### winlink1000OduAdmin OBJECT IDENTIFIER ::= { winlink1000Odu 1 } winlink1000OduAdmProductType OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "ODU configuration description." ::= { winlink1000OduAdmin 1 } winlink1000OduAdmHwRev OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "ODU Hardware Version." ::= { winlink1000OduAdmin 2 } winlink1000OduAdmSwRev OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "ODU Software Version." ::= { winlink1000OduAdmin 3 } winlink1000OduAdmLinkName OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Link Name. A change is effective immediately." ::= { winlink1000OduAdmin 4 } winlink1000OduAdmResetCmd OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Reset Command. A set command with a value of 3 will cause a device reset. The read value is always 0." ::= { winlink1000OduAdmin 5 } winlink1000OduAdmAddres OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "ODU IP address. A change is effective after reset. The parameter is kept for backward compatibility. Using the alternative parameter: winlink1000OduAdmIpParamsCnfg is recommended." ::= { winlink1000OduAdmin 6 } winlink1000OduAdmMask OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "ODU Subnet Mask. A change is effective after reset. The parameter is kept for backward compatibility. Using the alternative parameter: winlink1000OduAdmIpParamsCnfg is recommended." ::= { winlink1000OduAdmin 7 } winlink1000OduAdmGateway OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "ODU default gateway. A change is effective after reset. The parameter is kept for backward compatibility. Using the alternative parameter: winlink1000OduAdmIpParamsCnfg is recommended." ::= { winlink1000OduAdmin 8 } winlink1000OduAdmBroadcast OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "This parameter is reserved for the Manager application provided with the product." ::= { winlink1000OduAdmin 10 } winlink1000OduAdmHwModel OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Return the HW Model due to the HW Capabilities support" ::= { winlink1000OduAdmin 11 } -- ########################################################### -- ODU Admin Hosts Table -- ########################################################### winlink1000OduAdmHostsTable OBJECT-TYPE SYNTAX SEQUENCE OF Winlink1000OduAdmHostsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Trap destinations table. Each trap destination is defined by an IP address and a UDP port. Up to 10 addresses can be configured." ::= { winlink1000OduAdmin 12 } winlink1000OduAdmHostsEntry OBJECT-TYPE SYNTAX Winlink1000OduAdmHostsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Trap destinations table entry." INDEX { winlink1000OduAdmHostsIndex } ::= { winlink1000OduAdmHostsTable 1 } Winlink1000OduAdmHostsEntry ::= SEQUENCE { winlink1000OduAdmHostsIndex INTEGER, winlink1000OduAdmHostsIp IpAddress, winlink1000OduAdmHostsPort INTEGER, winlink1000OduAdmHostsSecurityModel INTEGER, winlink1000OduAdmHostsUserName DisplayString, winlink1000OduAdmHostsPassword DisplayString, winlink1000OduAdmHostsIPv6 DisplayString } winlink1000OduAdmHostsIndex OBJECT-TYPE SYNTAX INTEGER (0..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "Trap destinations table index." ::= { winlink1000OduAdmHostsEntry 1 } winlink1000OduAdmHostsIp OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "Trap destination IP address. A change is effective immediately." ::= { winlink1000OduAdmHostsEntry 2 } winlink1000OduAdmHostsPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "UDP port of the trap destination. A change is effective immediately." ::= { winlink1000OduAdmHostsEntry 3 } winlink1000OduAdmHostsSecurityModel OBJECT-TYPE SYNTAX INTEGER { snmpv1(1), snmpv3(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Security model used for this trap generation." ::= { winlink1000OduAdmHostsEntry 4 } winlink1000OduAdmHostsUserName OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "User name used to generate the snmpv3 trap." ::= { winlink1000OduAdmHostsEntry 5 } winlink1000OduAdmHostsPassword OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Password used to generate the snmpv3 trap." ::= { winlink1000OduAdmHostsEntry 6 } winlink1000OduAdmHostsIPv6 OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Trap destination IPv6 address. A change is effective immediately." ::= { winlink1000OduAdmHostsEntry 7 } winlink1000OduBuzzerAdminState OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "This parameter controls the activation of the buzzer while the unit is in install mode. A change is effective immediately. The valid values are: disabled (0), enabledAuto (1), enabledConstantly(2), advancedAuto (3)." ::= { winlink1000OduAdmin 13 } winlink1000OduProductId OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This parameter is reserved for the Manager application provided with the product." ::= { winlink1000OduAdmin 14 } winlink1000OduReadCommunity OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Read Community String. This parameter always returns ***** when retrieving its value. It is used by the Manager application to change the Read Community String. The SNMP agent accepts only encrypted values." ::= { winlink1000OduAdmin 15 } winlink1000OduReadWriteCommunity OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Read/Write Community String. This parameter always returns ***** when retrieving its value. It is used by the Manager application to change the Read/Write Community String. The SNMP agent accepts only encrypted values." ::= { winlink1000OduAdmin 16 } winlink1000OduTrapCommunity OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Trap Community String. This parameter is used by the Manager application to change the Trap Community String. The SNMP agent accepts only encrypted values." ::= { winlink1000OduAdmin 17 } winlink1000OduAdmSnmpAgentVersion OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Major version of the SNMP agent." ::= { winlink1000OduAdmin 18 } winlink1000OduAdmRemoteSiteName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Remote site name. Returns the same value as sysLocation parameter of the remote site." ::= { winlink1000OduAdmin 19 } winlink1000OduAdmSnmpAgentMinorVersion OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Minor version of the SNMP agent." ::= { winlink1000OduAdmin 20 } winlink1000OduAdmLinkPassword OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Link Password. This parameter always returns ***** when retrieving its value. It is used by the Manager application to change the Link Password. The SNMP agent accepts only encrypted values." ::= { winlink1000OduAdmin 21 } winlink1000OduAdmSiteLinkPassword OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Site Link Password. This parameter always returns ***** when retrieving its value. It is used by the Manager application to change the Link Password of the site. The SNMP agent accepts only encrypted values." ::= { winlink1000OduAdmin 22 } winlink1000OduAdmDefaultPassword OBJECT-TYPE SYNTAX INTEGER { default(1), nonDefault(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This parameter indicates if the current Link Password is the default password." ::= { winlink1000OduAdmin 23 } winlink1000OduAdmConnectionType OBJECT-TYPE SYNTAX INTEGER { directConnection(1), indirectConnection(2), unknown(3) } ACCESS read-only STATUS mandatory DESCRIPTION "This parameter indicates if the Manager application is connected to the local ODU or to the remote ODU over the air. A value of 'unknown' indicates community string mismatch." ::= { winlink1000OduAdmin 24 } winlink1000OduAdmBackToFactorySettingsCmd OBJECT-TYPE SYNTAX INTEGER { withIP(1), withoutIP(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Back to factory settings Command. A change is effective after reset. The read value is always 0." ::= { winlink1000OduAdmin 25 } winlink1000OduAdmIpParamsCnfg OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "ODU IP address Configuration. The format is: |||" ::= { winlink1000OduAdmin 26 } winlink1000OduAdmVlanID OBJECT-TYPE SYNTAX INTEGER (0..4094) ACCESS read-write STATUS mandatory DESCRIPTION "VLAN ID. Valid values are 1 to 4094. Initial value is 0 meaning VLAN unaware." ::= { winlink1000OduAdmin 27 } winlink1000OduAdmVlanPriority OBJECT-TYPE SYNTAX INTEGER (0..7) ACCESS read-write STATUS mandatory DESCRIPTION "VLAN Priority. 0 is lowest priority, 7 is highest priority." ::= { winlink1000OduAdmin 28 } winlink1000OduAdmSN OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "ODU Serial Number" ::= { winlink1000OduAdmin 29 } winlink1000OduAdmProductName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This is the product name as it exists at EC" ::= { winlink1000OduAdmin 30 } winlink1000OduAdmActivationKey OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Activates a general key." ::= { winlink1000OduAdmin 31 } winlink1000OduAdmRmtPermittedOduType OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Mobile Application: permitted partner OduType." ::= { winlink1000OduAdmin 32 } winlink1000OduAdmCpuID OBJECT-TYPE SYNTAX INTEGER (0..64) ACCESS read-only STATUS mandatory DESCRIPTION "CPU ID" ::= { winlink1000OduAdmin 33 } winlink1000OduAdmOvrdCmd OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Ability to perform special command in the ODU." ::= { winlink1000OduAdmin 34 } winlink1000OduAdmLinkMode OBJECT-TYPE SYNTAX INTEGER { pmpHbs (1), pmpHsu (2), pmpHsuHyb (3), pmpHbsHyb (4) } ACCESS read-write STATUS mandatory DESCRIPTION "Unit PMP operation mode." ::= { winlink1000OduAdmin 35 } winlink1000OduAdmActualConnectMode OBJECT-TYPE SYNTAX INTEGER { none (1), ptp (2), ptmp (3) } ACCESS read-only STATUS mandatory DESCRIPTION "Unit connected as part to ptp or ptmp." ::= { winlink1000OduAdmin 36 } winlink1000OduAdmAES256Support OBJECT-TYPE SYNTAX INTEGER { notSupported (1), supported (2) } ACCESS read-only STATUS mandatory DESCRIPTION "AES-256 security support indication." ::= { winlink1000OduAdmin 37 } winlink1000OduAdmAES256State OBJECT-TYPE SYNTAX INTEGER { disabled (1), enabled (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable/Disable AES-256 security mode over the air link." ::= { winlink1000OduAdmin 38 } winlink1000OduAdmAES256Status OBJECT-TYPE SYNTAX INTEGER { notOperating (1), partiallyOperating (2), operating (3) } ACCESS read-only STATUS mandatory DESCRIPTION "AES256 operating status" ::= { winlink1000OduAdmin 39 } winlink1000OduAdmBatterySavingShutdownTime OBJECT-TYPE SYNTAX INTEGER (0..1000) ACCESS read-write STATUS mandatory DESCRIPTION "Battery Saving Shutdown Time in minutes, 0 till battery run out, -1 if not supported." ::= { winlink1000OduAdmin 40 } winlink1000OduAdmWiFiPowerMode OBJECT-TYPE SYNTAX INTEGER { undefined-ReadOnly (1), powerON (2), powerOFF (3), alwaysON-ReadOnly (4), powerAUTO (5), limitedTime (6) } ACCESS read-write STATUS mandatory DESCRIPTION "WIFI unit power mode." ::= { winlink1000OduAdmin 41 } winlink1000OduAdmShutdownTimer OBJECT-TYPE SYNTAX INTEGER (0..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "Shutdown Timer in seconds." ::= { winlink1000OduAdmin 42 } winlink1000OduAdmGPSState OBJECT-TYPE SYNTAX INTEGER { undefined (1), notSynchronized (2), fixed (3), shortCircuit (4), faulty (5), synchronizedGPS (6), synchronizedGlonassGPS (7), sychnornizedBeidouGPS(8) } ACCESS read-only STATUS mandatory DESCRIPTION "GPS state" ::= { winlink1000OduAdmin 43 } winlink1000OduAdmTemperatureC OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The temperature (Celsius) inside the Board." ::= { winlink1000OduAdmin 44 } winlink1000OduAdmIPStackMode OBJECT-TYPE SYNTAX INTEGER { v4 (1), v6 (2), v4andv6 (3) } ACCESS read-write STATUS mandatory DESCRIPTION "The IP stack mode." ::= { winlink1000OduAdmin 45 } winlink1000OduAdmIPv6ParamsCnfg OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "ODU IPv6 address Configuration. The format is: |||" ::= { winlink1000OduAdmin 46 } winlink1000OduAdmIPv6Address OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "ODU IPv6 address." ::= { winlink1000OduAdmin 47 } winlink1000OduAdmIPv6Prefix OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "ODU IPv6 subnet mask." ::= { winlink1000OduAdmin 48 } winlink1000OduAdmIPv6DefaultGateWay OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "ODU IPv6 default gateway." ::= { winlink1000OduAdmin 49 } winlink1000OduAdmPowerConsumption OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Power Consumption (mWatt)" ::= { winlink1000OduAdmin 50 } -- ########################################################### -- ODU Wifi -- ########################################################### winlink1000OduAdmWifi OBJECT IDENTIFIER ::= { winlink1000OduAdmin 51 } winlink1000OduAdmWifiChannel OBJECT-TYPE SYNTAX INTEGER (1..11) ACCESS read-write STATUS mandatory DESCRIPTION "Wifi Channel" ::= { winlink1000OduAdmWifi 1 } winlink1000OduAdmWifiTxPower OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Wifi TX Power" ::= { winlink1000OduAdmWifi 2 } winlink1000OduAdmWifiSSID OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Wifi SSID" ::= { winlink1000OduAdmWifi 3 } winlink1000OduAdmWifiSecurityType OBJECT-TYPE SYNTAX INTEGER { open (1), wep (2), wpa2 (3) } ACCESS read-only STATUS mandatory DESCRIPTION "Wifi Security type" ::= { winlink1000OduAdmWifi 4 } winlink1000OduAdmWifiPassword OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Wifi Password" ::= { winlink1000OduAdmWifi 5 } winlink1000OduAdmWifiNetwork OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "Wifi Network" ::= { winlink1000OduAdmWifi 6 } winlink1000OduAdmWifiRssi OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Wifi RSSI" ::= { winlink1000OduAdmWifi 7 } winlink1000OduAdmWifiStationMAC OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Wifi Station MAC" ::= { winlink1000OduAdmWifi 8 } winlink1000OduAdmWifiRestart OBJECT-TYPE SYNTAX INTEGER (1) ACCESS read-write STATUS mandatory DESCRIPTION "A set command with a value of 1 will cause a Wifi restart. The read value is always 0." ::= { winlink1000OduAdmWifi 9 } winlink1000OduAdmWifiApStatus OBJECT-TYPE SYNTAX INTEGER { off (1), on (2), connected (3), limited (4) } ACCESS read-only STATUS mandatory DESCRIPTION "Wifi AP Status" ::= { winlink1000OduAdmWifi 10 } winlink1000OduAdmWifiMaxTxPower OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Wifi Max Tx Power" ::= { winlink1000OduAdmWifi 11 } -- ########################################################### -- Wifi Rssi Table -- ########################################################### winlink1000OduAdmWiFiRssiTable OBJECT-TYPE SYNTAX SEQUENCE OF Winlink1000OduAdmWiFiRssiAndMacEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of Wifi Rssi And Mac adress per connected user." ::= { winlink1000OduAdmWifi 12 } winlink1000OduAdmWiFiRssiAndMacEntry OBJECT-TYPE SYNTAX Winlink1000OduAdmWiFiRssiAndMacEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Wifi Rssi And Mac adress per connected user table entry." INDEX { winlink1000OduAdmWiFiRssiAndMacIndex } ::= { winlink1000OduAdmWiFiRssiTable 1 } Winlink1000OduAdmWiFiRssiAndMacEntry ::= SEQUENCE { winlink1000OduAdmWiFiRssiAndMacIndex INTEGER, winlink1000OduAdmWiFiRssiAndMac DisplayString } winlink1000OduAdmWiFiRssiAndMacIndex OBJECT-TYPE SYNTAX INTEGER (0..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "Wifi Rssi And Mac adress per connected user Index." ::= { winlink1000OduAdmWiFiRssiAndMacEntry 1 } winlink1000OduAdmWiFiRssiAndMac OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Wifi Rssi And Mac adress per connected user value." ::= { winlink1000OduAdmWiFiRssiAndMacEntry 2 } winlink1000OduAdmBsaOperationMode OBJECT-TYPE SYNTAX INTEGER { inactive (1), hbsTracking (2), hsuAlignment (3) } ACCESS read-only STATUS mandatory DESCRIPTION "BSA Operation Mode" ::= { winlink1000OduAdmin 52 } winlink1000OduAdmMngConnection OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Management Connection" ::= { winlink1000OduAdmin 53 } winlink1000OduAdm1588TCSupport OBJECT-TYPE SYNTAX INTEGER { notSupported (1), supported (2) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates that 1588TC license activated" ::= { winlink1000OduAdmin 54 } winlink1000OduAdmSyncESupport OBJECT-TYPE SYNTAX INTEGER { notSupported (1), supported (2) } ACCESS read-only STATUS mandatory DESCRIPTION "ndicates that SyncE license activated" ::= { winlink1000OduAdmin 55 } winlink1000OduAdmRadioRev OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Radio Revision" ::= { winlink1000OduAdmin 56 } winlink1000OduAdmProductRev OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Product Revision" ::= { winlink1000OduAdmin 57 } winlink1000OduAdmPMPSUSupport OBJECT-TYPE SYNTAX INTEGER { notSupported (1), supported (2) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates that PMP SU license is activated" ::= { winlink1000OduAdmin 58 } winlink1000OduAdmManagerDownloadURL OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "This is the URL from which management tool can be downloaded" ::= { winlink1000OduAdmin 59 } winlink1000OduAdmAntennaDescription OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The is a description of the antenna connected to the ODU" ::= { winlink1000OduAdmin 60 } winlink1000OduAdmSwCapabilities OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This is used to describe which Software Capabilities the current ODU supports" ::= { winlink1000OduAdmin 61 } -- ########################################################### -- ODU Software Change -- ########################################################### winlink1000OduAdmSwChange OBJECT IDENTIFIER ::= { winlink1000OduAdmin 62 } winlink1000OduAdmSwChangeCommand OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION " Software Change Commands (string): Validate: 1, Mode Start: 2, Mode Download: 3, Mode, URL Upload: 4, Mode, URL Clean: 5, [SizeInBytes] Backup: 6, [DateTime] Mode: SW Upgrade(1), Backup/Restore(2) " ::= { winlink1000OduAdmSwChange 1 } winlink1000OduAdmSwChangeMetadata OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Software Metadata String" ::= { winlink1000OduAdmSwChange 2 } winlink1000OduAdmSwChangeStatus OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Software Change Operation status: None (1), In Progress (2), Pending Reset (3), Error (4)" ::= { winlink1000OduAdmSwChange 3 } winlink1000OduAdmSwChangeError OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Software Change Operation Error String" ::= { winlink1000OduAdmSwChange 4 } winlink1000OduAdmRequesterSourceIp OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "Returns the SNMP request's source IP address" ::= { winlink1000OduAdmin 63 } winlink1000OduAdmSecurityMode OBJECT-TYPE SYNTAX INTEGER { standard (1), high (2), veryHigh (3) } ACCESS read-write STATUS mandatory DESCRIPTION " ODUs Security Mode : standard (1) high (2) veryHigh (3) " ::= { winlink1000OduAdmin 64 } winlink1000OduAdmTemporarilyDisableSecurityMode OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "shall allow the user to disable high/very high Security Mode for 10 minutes" ::= { winlink1000OduAdmin 65 } winlink1000OduAdmSyslogServerIp OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "Syslog server Ip address" ::= { winlink1000OduAdmin 66 } -- ########################################################### -- ODU Logger Tool Section -- ########################################################### -- winlink1000OduAdmin 67 - Hidden Folder - winlink1000OduAdmLogger -- winlink1000OduAdmin 67.1 - winlink1000OduAdmLogger 1 -Hidden mib winlink1000OduAdmLoggerCmd winlink1000OduAdmReportSwOperation OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Reports Syslog client on software operation: Configuration Restore Software Upgrade Restore Default Full Restore Backup" ::= { winlink1000OduAdmin 68 } -- ########################################################## winlink1000OduAdmBootVersion OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Card Boot version" ::= { winlink1000OduAdmin 69 } winlink1000OduAdmOneTimePassword OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "One Time Password" ::= { winlink1000OduAdmin 70 } winlink1000OduAdmSupportExtendedImage OBJECT-TYPE SYNTAX INTEGER { na (1), supportedLoaded (2), supportedNotLoaded (3), notSupported (4) } ACCESS read-only STATUS mandatory DESCRIPTION "ODU Support Extended Image N/A (1), Supported and Loaded (2), Supported and not Loaded (3), Not Supported (4) " ::= { winlink1000OduAdmin 71 } -- ########################################################### -- ODU FiM -- ########################################################### winlink1000OduAdmFiM OBJECT IDENTIFIER ::= { winlink1000OduAdmin 72 } -- ########################################################### -- BS -- ########################################################### winlink1000OduAdmFiMBS OBJECT IDENTIFIER ::= { winlink1000OduAdmFiM 1 } -- ########################################################### -- BS-Air -- ########################################################### winlink1000OduAdmFiMBSAir OBJECT IDENTIFIER ::= { winlink1000OduAdmFiMBS 1 } winlink1000OduAdminFiMBSAirRUF OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "For a limited spectrum case (when there are less then 5 channels), the number of available channels. A frequency can be reused for several TBS." ::= { winlink1000OduAdmFiMBSAir 1 } winlink1000OduAdminFiMBSAirITHOType OBJECT-TYPE SYNTAX INTEGER { enabled (1), disabled (2), notSupported (3) } ACCESS read-only STATUS mandatory DESCRIPTION "Seamless Intra Mobile Handover. Return values: 1 - Enabled 2 - Disabled 3 - Not supported" ::= { winlink1000OduAdmFiMBSAir 2 } winlink1000OduAdminFiMBSAirBIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "For limited spectrum availability, a frequency can be reused for several TBSs. To avoid interference TBSs with the same frrequency will tranmit the beacon with different offset." ::= { winlink1000OduAdmFiMBSAir 3 } winlink1000OduAdminFiMBSAirTSGIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Used for Interference Mitigation for Co-channel Neighbors. Returns which TBS group use which timeslots in a frame." ::= { winlink1000OduAdmFiMBSAir 4 } winlink1000OduAdminFiMBSAirITHOMode OBJECT-TYPE SYNTAX INTEGER { basedTput (1), basedRSS (2) } ACCESS read-only STATUS mandatory DESCRIPTION "ITHO decision based on: 1 - Tput 2 - RSS" ::= { winlink1000OduAdmFiMBSAir 5 } winlink1000OduAdminFiMBSAirHOTable OBJECT-TYPE SYNTAX SEQUENCE OF Winlink1000OduAdminFiMBSAirHOEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Details of geographic neighbor of a TBS. This data is required to enable HO." ::= { winlink1000OduAdmFiMBSAir 6 } winlink1000OduAdminFiMBSAirHOEntry OBJECT-TYPE SYNTAX Winlink1000OduAdminFiMBSAirHOEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Entry" INDEX {winlink1000OduAdminFiMBSAirHOIndex} ::= { winlink1000OduAdminFiMBSAirHOTable 1 } Winlink1000OduAdminFiMBSAirHOEntry ::= SEQUENCE { winlink1000OduAdminFiMBSAirHOIndex INTEGER, winlink1000OduAdminFiMBSAirHOFreq INTEGER, winlink1000OduAdminFiMBSAirHOIP IpAddress } winlink1000OduAdminFiMBSAirHOIndex OBJECT-TYPE SYNTAX INTEGER (0..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "index" ::= { winlink1000OduAdminFiMBSAirHOEntry 1 } winlink1000OduAdminFiMBSAirHOFreq OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The Frequncy (channel) of the neighboring TBS." ::= { winlink1000OduAdminFiMBSAirHOEntry 2 } winlink1000OduAdminFiMBSAirHOIP OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "The IP addresses of the neighboring TBS." ::= { winlink1000OduAdminFiMBSAirHOEntry 3 } winlink1000OduAdminFiMBSAirCoCHIPTable OBJECT-TYPE SYNTAX SEQUENCE OF Winlink1000OduAdminFiMBSAirCoCHIPEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Details of TBSs that use the same channel. This is required for interference mitigation." ::= { winlink1000OduAdmFiMBSAir 7 } winlink1000OduAdminFiMBSAirCoCHIPEntry OBJECT-TYPE SYNTAX Winlink1000OduAdminFiMBSAirCoCHIPEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Entry" INDEX {winlink1000OduAdminFiMBSAirCoCHIndex } ::= { winlink1000OduAdminFiMBSAirCoCHIPTable 1 } Winlink1000OduAdminFiMBSAirCoCHIPEntry ::= SEQUENCE { winlink1000OduAdminFiMBSAirCoCHIndex INTEGER, winlink1000OduAdminFiMBSAirCoCHIP IpAddress } winlink1000OduAdminFiMBSAirCoCHIndex OBJECT-TYPE SYNTAX INTEGER (0..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "index" ::= { winlink1000OduAdminFiMBSAirCoCHIPEntry 1 } winlink1000OduAdminFiMBSAirCoCHIP OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "The IP addresses of the co-channel TBS." ::= { winlink1000OduAdminFiMBSAirCoCHIPEntry 2 } winlink1000OduAdminFiMBSAirDepoTrackSegment OBJECT-TYPE SYNTAX INTEGER { track(1), depot(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This parameter indicates TBSs covering the depot using connectivity enhancements" ::= { winlink1000OduAdmFiMBSAir 8 } -- ########################################################### -- BS-Net -- ########################################################### winlink1000OduAdmFiMBSNet OBJECT IDENTIFIER ::= { winlink1000OduAdmFiMBS 2 } winlink1000OduAdminFiMBSNetType OBJECT-TYPE SYNTAX INTEGER { mdlEnabled (1), mdlDisabled (2), mdlNotSupported (3), l3 (4), workModeAmount (5) } ACCESS read-only STATUS mandatory DESCRIPTION "Mobility method. Depends on the track-side network architecture: Layer 2-Single MAC, Layer 2-Multi MAC or L3 Return values: 1 - MDL Enabled 2 - MDL disabled 3 - MDL not supported 4 - L3 5 - Work mode amount" ::= { winlink1000OduAdmFiMBSNet 1 } winlink1000OduAdminFiMBSNetCenterNetPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "CenterNet controller port. Returns an integer." ::= { winlink1000OduAdmFiMBSNet 2 } winlink1000OduAdminFiMBSNetCenterNetTable OBJECT-TYPE SYNTAX SEQUENCE OF Winlink1000OduAdminFiMBSNetCenterNetEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "CenterNet controlle, table of entries defined in next MIB item" ::= { winlink1000OduAdmFiMBSNet 3 } winlink1000OduAdminFiMBSNetCenterNetEntry OBJECT-TYPE SYNTAX Winlink1000OduAdminFiMBSNetCenterNetEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "CenterNet table entry type (Integer, IP address)" INDEX {winlink1000OduAdminFiMBSNetCenterNetIndex } ::= { winlink1000OduAdminFiMBSNetCenterNetTable 1 } Winlink1000OduAdminFiMBSNetCenterNetEntry ::= SEQUENCE { winlink1000OduAdminFiMBSNetCenterNetIndex INTEGER, winlink1000OduAdminFiMBSNetCenterNetIP IpAddress } winlink1000OduAdminFiMBSNetCenterNetIndex OBJECT-TYPE SYNTAX INTEGER (0..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "CenterNet table current entry index. Set it to select an entry." ::= { winlink1000OduAdminFiMBSNetCenterNetEntry 1 } winlink1000OduAdminFiMBSNetCenterNetIP OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "IP address" ::= { winlink1000OduAdminFiMBSNetCenterNetEntry 2 } -- ########################################################### -- BS-Sync -- ########################################################### winlink1000OduAdmFiMBSSync OBJECT IDENTIFIER ::= { winlink1000OduAdmFiMBS 3 } winlink1000OduAdminFiMBSSyncTC OBJECT-TYPE SYNTAX INTEGER { enabled (1), disabled (2) } ACCESS read-only STATUS mandatory DESCRIPTION "1588 Transparent Clock (TC) status. Return values: 1 - Enabled 2 - Disabled" ::= { winlink1000OduAdmFiMBSSync 1 } winlink1000OduAdminFiMBSSyncJitter OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Ethernet Hub Site Synchronization jitter mitigation: If there is a high level of wayside network jitter, use this to minimize the adverse affect of jitter on transmission synchronization. Returns an integer threshold value." ::= { winlink1000OduAdmFiMBSSync 2 } -- ########################################################### -- BS-EACS -- ########################################################### winlink1000OduAdmFiMBSEACS OBJECT IDENTIFIER ::= { winlink1000OduAdmFiMBS 4 } winlink1000OduAdminFiMEACSEN OBJECT-TYPE SYNTAX INTEGER { eacsDisabled (1), eacsEnabled (2) } ACCESS read-only STATUS mandatory DESCRIPTION "Enhanced automatic Channel Selection. When ON, enables to move to alternative channel if radar was detedcted for the current channel." ::= { winlink1000OduAdmFiMBSEACS 2 } winlink1000OduAdminFiMEACSCHPRIO OBJECT-TYPE SYNTAX INTEGER (0..15) ACCESS read-only STATUS mandatory DESCRIPTION "When EACS is activated, you can define alternative channels with priority." ::= { winlink1000OduAdmFiMBSEACS 3 } winlink1000OduAdminFiMEACSDFSTRIGGER OBJECT-TYPE SYNTAX INTEGER { regular (1), immediateReturn (2) } ACCESS read-only STATUS mandatory DESCRIPTION "Get the policy mode where an alternative channel with high priority was cleared: ignore or move back to it. Return values: 1 - Regular 2 - IR" ::= { winlink1000OduAdmFiMBSEACS 4 } winlink1000OduAdminFiMEACSPMAN OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "When EACS is in use: Each TBS needs to know its predecessor TBS. This requires that each TBS sends it successor a periodic update message notifying its existence. The PNAM interval sets the time interval between these messages." ::= { winlink1000OduAdmFiMBSEACS 5 } winlink1000OduAdminFiBEACSSELFHEALING OBJECT-TYPE SYNTAX INTEGER { selfHealSupportDisabled (1), selfHealSupportEnalbed (2) } ACCESS read-only STATUS mandatory DESCRIPTION "Enhanced automatic Channel Selection Self Healing functionality. When ON, enables Self Healing." ::= { winlink1000OduAdmFiMBSEACS 6 } winlink1000OduAdminFiBEacsSwitchStatus OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Eacs last switch reason and switching counter." ::= { winlink1000OduAdmFiMBSEACS 7 } -- ########################################################### -- MU -- ########################################################### winlink1000OduAdmFiMMU OBJECT IDENTIFIER ::= { winlink1000OduAdmFiM 2 } -- ########################################################### -- MU-Air -- ########################################################### winlink1000OduAdmFiMMUAir OBJECT IDENTIFIER ::= { winlink1000OduAdmFiMMU 1 } winlink1000OduAdminFiMMUAirServBS OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "Current BS the TMU actively linked to." ::= { winlink1000OduAdmFiMMUAir 1 } winlink1000OduAdminFiMMUAirRole OBJECT-TYPE SYNTAX INTEGER { active (1), passive (2) } ACCESS read-only STATUS mandatory DESCRIPTION "TMU may be active or passive. This indicates the currents state." ::= { winlink1000OduAdmFiMMUAir 2 } winlink1000OduAdminFiMMUAirHOMode OBJECT-TYPE SYNTAX INTEGER { upLink (1), aggregate (2), downLink (3) } ACCESS read-only STATUS mandatory DESCRIPTION "Applicability of the Intra Train Handover (ITHO) throughput ratio. Return values: 1 - Uplink 2 - Aggregate 3 - Downlink" ::= { winlink1000OduAdmFiMMUAir 3 } winlink1000OduAdminFiMMUAirIBHOType OBJECT-TYPE SYNTAX INTEGER { disabled (1), enabled (2) } ACCESS read-only STATUS mandatory DESCRIPTION "IBHO occurs when TMU moves from one TBS to the next. It is possible to force TMU to move to other TBS only when it is passive." ::= { winlink1000OduAdmFiMMUAir 4 } -- ########################################################### -- MU-Net -- ########################################################### winlink1000OduAdmFiMMUNet OBJECT IDENTIFIER ::= { winlink1000OduAdmFiMMU 2 } winlink1000OduAdminFiMMUNetR1IP OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "Car router IP for L2 configuration. Returns an IP address string." ::= { winlink1000OduAdmFiMMUNet 1 } winlink1000OduAdminFiMMUNetLANTable OBJECT-TYPE SYNTAX SEQUENCE OF Winlink1000OduAdminFiMMUNetLANEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "For L3 network types: A list of IP subnet prefixes and subnet masks for the train. No more than 5 can be entered." ::= { winlink1000OduAdmFiMMUNet 2 } winlink1000OduAdminFiMMUNetLANEntry OBJECT-TYPE SYNTAX Winlink1000OduAdminFiMMUNetLANEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Entry" INDEX {winlink1000OduAdminFiMMUNetLANIndex} ::= { winlink1000OduAdminFiMMUNetLANTable 1 } Winlink1000OduAdminFiMMUNetLANEntry ::= SEQUENCE { winlink1000OduAdminFiMMUNetLANIndex INTEGER, winlink1000OduAdminFiMMUNetLAN IpAddress, winlink1000OduAdminFiMMUNetMaskLAN IpAddress } winlink1000OduAdminFiMMUNetLANIndex OBJECT-TYPE SYNTAX INTEGER (0..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "Index" ::= { winlink1000OduAdminFiMMUNetLANEntry 1 } winlink1000OduAdminFiMMUNetLAN OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "LAN prefix" ::= { winlink1000OduAdminFiMMUNetLANEntry 2 } winlink1000OduAdminFiMMUNetMaskLAN OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "LAN mask" ::= { winlink1000OduAdminFiMMUNetLANEntry 3 } winlink1000OduAdminFiMMUNetL3VIP OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "For L3 network types: The TMUs on-board share a virtual IP that serves as the default gateway for the on-board router (the actual TMU accessed is the active TMU)." ::= { winlink1000OduAdmFiMMUNet 3 } winlink1000OduAdminFiMMUNetPeer OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "The IP of the peer TMU or TMUs in the same train." ::= { winlink1000OduAdmFiMMUNet 4 } winlink1000OduAdminFiMMUNetType OBJECT-TYPE SYNTAX INTEGER { mdlEnabled (1), mdlDisabled (2), mdlNotSupported (3), l3 (4), workModeAmount (5) } ACCESS read-only STATUS mandatory DESCRIPTION "Mobility method. Depends on the track-side network architecture: Layer 2-Single MAC, Layer 2-Multi MAC or L3 Return values: 1 - MDL Enabled 2 - MDL disabled 3 - MDL not supported 4 - L3 5 - Work mode amount" ::= { winlink1000OduAdmFiMMUNet 5 } winlink1000OduAdminFiMMUNetAddLearnVLANTable OBJECT-TYPE SYNTAX SEQUENCE OF Winlink1000OduAdminFiMMUNetAddLearnVLANEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "There is an option to send relearning frames between TMUs via VLAN - not in use, ask PS before using this option" ::= { winlink1000OduAdmFiMMUNet 6 } winlink1000OduAdminFiMMUIthoMuMode OBJECT-TYPE SYNTAX INTEGER { singleMode (1), dualMode (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Mobility : option to set Mu Itho mode of behaviour values: 1 - Single Mode - single Mu on train does not perform itho 2 - Dual Mode - Mu have a peer and performs Itho " ::= { winlink1000OduAdmFiMMUNet 7 } winlink1000OduAdminFiMMUNetAddLearnVLANEntry OBJECT-TYPE SYNTAX Winlink1000OduAdminFiMMUNetAddLearnVLANEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "entry" INDEX {winlink1000OduAdminFiMMUNetAddLearnVLANIndex} ::= { winlink1000OduAdminFiMMUNetAddLearnVLANTable 1 } Winlink1000OduAdminFiMMUNetAddLearnVLANEntry ::= SEQUENCE { winlink1000OduAdminFiMMUNetAddLearnVLANIndex INTEGER, winlink1000OduAdminFiMMUNetAddLearnVLAN INTEGER } winlink1000OduAdminFiMMUNetAddLearnVLANIndex OBJECT-TYPE SYNTAX INTEGER (0..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "Index" ::= { winlink1000OduAdminFiMMUNetAddLearnVLANEntry 1 } winlink1000OduAdminFiMMUNetAddLearnVLAN OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "VLAN" ::= { winlink1000OduAdminFiMMUNetAddLearnVLANEntry 2 } -- ########################################################### -- ODU TVWS -- ########################################################### winlink1000OduAdmDnsServerAddress OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Primary and Secondary DNS addresses: ||" ::= { winlink1000OduAdmin 73 } winlink1000OduAdmOwner OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Name of Individual/business that owns the device" ::= { winlink1000OduAdmin 74 } winlink1000OduAdmContactDetails OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Contact Details: ||||||" ::= { winlink1000OduAdmin 75 } winlink1000OduAdmSDRRevision OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "SDR (Software defined radio) revision" ::= { winlink1000OduAdmin 76 } winlink1000OduAdmDyingGaspStatus OBJECT-TYPE SYNTAX INTEGER{ notSupportedHW (1), supportedOnlyOnSu (2), notActiveCheckPoe (3), active (4), testing (5) } ACCESS read-only STATUS mandatory DESCRIPTION "Activity status of Dying Gasp: power fail detection. Return values: 1 - Not supported- no HW 2 - Not active- supported only on the SU end 3 - Not active- please check your PoE device 4 - Active 5 - Testing" ::= { winlink1000OduAdmin 77 } -- ########################################################### -- ODU Service -- ########################################################### winlink1000OduService OBJECT IDENTIFIER ::= { winlink1000Odu 2 } winlink1000OduSrvMode OBJECT-TYPE SYNTAX INTEGER { installMode (1), normalMode (2), slaveMode (3), tempInstallMode (4), inactiveMode (5) } ACCESS read-write STATUS mandatory DESCRIPTION "System mode. The only values that can be set are installMode and slaveMode; normalMode reserved to the Manager application provided with the product. A change is effective after link re-synchronization." ::= { winlink1000OduService 1 } winlink1000OduSrvBridging OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Bridging Mode. Valid values are: disabled (0), enabled (1)." ::= { winlink1000OduService 3 } -- ########################################################### -- ODU Ring Topology -- ########################################################### winlink1000OduServiceRingTopology OBJECT IDENTIFIER ::= { winlink1000OduService 4 } winlink1000OduSrvRingLinkMode OBJECT-TYPE SYNTAX INTEGER { independentLink (1), nonRpl (2), rpl (3) } ACCESS read-write STATUS mandatory DESCRIPTION "Mode of the link regarding ring topology." ::= { winlink1000OduServiceRingTopology 1 } winlink1000OduSrvRingTopologySupported OBJECT-TYPE SYNTAX INTEGER { notSupported (1), supported (2) } ACCESS read-only STATUS mandatory DESCRIPTION "Ring Topology, options are: supported, not supported" ::= { winlink1000OduServiceRingTopology 2 } winlink1000OduSrvRingVlanIdTable OBJECT-TYPE SYNTAX SEQUENCE OF Winlink1000OduSrvRingVlanIdEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Ring VLAN IDs table." ::= { winlink1000OduServiceRingTopology 3 } winlink1000OduSrvRingVlanIdEntry OBJECT-TYPE SYNTAX Winlink1000OduSrvRingVlanIdEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "VLAN ID of the internal ring messages. Valid values are 1 to 4094. Initial value is 0 meaning VLAN unaware." INDEX { winlink1000OduSrvRingVlanIdIndex } ::= { winlink1000OduSrvRingVlanIdTable 1 } Winlink1000OduSrvRingVlanIdEntry ::= SEQUENCE { winlink1000OduSrvRingVlanIdIndex INTEGER, winlink1000OduSrvRingVlanId INTEGER } winlink1000OduSrvRingVlanIdIndex OBJECT-TYPE SYNTAX INTEGER (0..3) ACCESS read-only STATUS mandatory DESCRIPTION "Index of VLAN ID of the internal ring messages." ::= { winlink1000OduSrvRingVlanIdEntry 1 } winlink1000OduSrvRingVlanId OBJECT-TYPE SYNTAX INTEGER (0..4094) ACCESS read-write STATUS mandatory DESCRIPTION "VLAN ID of the internal ring messages. Valid values are 1 to 4094. Initial value is 0 meaning VLAN unaware." ::= { winlink1000OduSrvRingVlanIdEntry 2 } winlink1000OduSrvRingEthStatus OBJECT-TYPE SYNTAX INTEGER { unblocked(1), blocked(2), notApplicable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Represents the Ethernet service blocking state of a Rings link" ::= { winlink1000OduServiceRingTopology 4 } winlink1000OduSrvRingMaxAllowedTimeFromLastRpm OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Defines the minimal time (in ms) required for determination of ring failure." ::= { winlink1000OduServiceRingTopology 5 } winlink1000OduSrvRingWTR OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Defines the minimal time (in ms) required for ring recovery." ::= { winlink1000OduServiceRingTopology 6 } -- ########################################################### -- ODU QoS -- ########################################################### winlink1000OduServiceQoS OBJECT IDENTIFIER ::= { winlink1000OduService 5 } winlink1000OduSrvQoSMode OBJECT-TYPE SYNTAX INTEGER { notSupported (1), notActive (2), classVlan (3), classDiffserv (4) } ACCESS read-write STATUS mandatory DESCRIPTION "Mode of QoS feature." ::= { winlink1000OduServiceQoS 1 } winlink1000OduSrvQoSConfTable OBJECT-TYPE SYNTAX SEQUENCE OF Winlink1000OduSrvQoSConfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "QoS configuration table." ::= { winlink1000OduServiceQoS 2 } winlink1000OduSrvQoSConfEntry OBJECT-TYPE SYNTAX Winlink1000OduSrvQoSConfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "QoS configuration table." INDEX { winlink1000OduSrvQoSConfIndex } ::= { winlink1000OduSrvQoSConfTable 1 } Winlink1000OduSrvQoSConfEntry ::= SEQUENCE { winlink1000OduSrvQoSConfIndex INTEGER, winlink1000OduSrvConfVlanQGroups INTEGER, winlink1000OduSrvConfDiffservQGroups INTEGER, winlink1000OduSrvConfQueMir INTEGER, winlink1000OduSrvConfQueWeight INTEGER } winlink1000OduSrvQoSConfIndex OBJECT-TYPE SYNTAX INTEGER (0..3) ACCESS read-only STATUS mandatory DESCRIPTION "Index of QoS Configuration." ::= { winlink1000OduSrvQoSConfEntry 1 } winlink1000OduSrvConfVlanQGroups OBJECT-TYPE SYNTAX INTEGER (0..7) ACCESS read-only STATUS mandatory DESCRIPTION "Frames classification according to VLAN Priority IDs." ::= { winlink1000OduSrvQoSConfEntry 2 } winlink1000OduSrvConfDiffservQGroups OBJECT-TYPE SYNTAX INTEGER (0..48) ACCESS read-only STATUS mandatory DESCRIPTION "Frames classification according to Diffserv." ::= { winlink1000OduSrvQoSConfEntry 3 } winlink1000OduSrvConfQueMir OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Desired Private MIR." ::= { winlink1000OduSrvQoSConfEntry 4 } winlink1000OduSrvConfQueWeight OBJECT-TYPE SYNTAX INTEGER (0..100) ACCESS read-write STATUS mandatory DESCRIPTION "QoS queueu's weights in percent." ::= { winlink1000OduSrvQoSConfEntry 5 } winlink1000OduSrvQoSVlanQGroupsSetStr OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Frames classification according to VLAN IDs string for set." ::= { winlink1000OduServiceQoS 3 } winlink1000OduSrvQoSDiffservQGroupsSetStr OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Frames classification according to Diffserv IDs string for set." ::= { winlink1000OduServiceQoS 4 } winlink1000OduSrvQoSMaxRTQuePercent OBJECT-TYPE SYNTAX INTEGER (0..100) ACCESS read-only STATUS mandatory DESCRIPTION "Maximal percent for RT & NRT queues." ::= { winlink1000OduServiceQoS 5 } -- ########################################################### -- ODU VLAN Configuration -- ########################################################### winlink1000OduServiceVlan OBJECT IDENTIFIER ::= { winlink1000OduService 6 } winlink1000OduSrvVlanSupport OBJECT-TYPE SYNTAX INTEGER { notSupported (1), supported(2), available(3) } ACCESS read-only STATUS mandatory DESCRIPTION "ODU Ethernet port VLAN support and configuration availability indication. 1 - ODU VLAN Functionality Not Supported 2 - ODU VLAN Functionality Supported 3 - ODU VLAN Functionality Supported and Available" ::= { winlink1000OduServiceVlan 1 } winlink1000OduSrvVlanIngressMode OBJECT-TYPE SYNTAX INTEGER { transparent (1), untagAll (2), filter (3) } ACCESS read-write STATUS mandatory DESCRIPTION "ODU Ethernet port ingress VLAN mode." ::= { winlink1000OduServiceVlan 2 } winlink1000OduSrvVlanEgressMode OBJECT-TYPE SYNTAX INTEGER { transparent (1), tag (2), provider (3) } ACCESS read-write STATUS mandatory DESCRIPTION "ODU Ethernet port egress VLAN mode." ::= { winlink1000OduServiceVlan 3 } winlink1000OduSrvEgressTag OBJECT-TYPE SYNTAX INTEGER (0..40947) ACCESS read-write STATUS mandatory DESCRIPTION "ODU ethernet port egress VLAN tag. Right most digit is Vlan priority (0-7), other digits compose Vlan Id (2-4094)" ::= { winlink1000OduServiceVlan 4 } winlink1000OduSrvEgressProviderTag OBJECT-TYPE SYNTAX INTEGER (0..40947) ACCESS read-write STATUS mandatory DESCRIPTION "ODU ethernet port egress Provider VLAN tag. Right most digit is Vlan priority (0-7), other digits compose Vlan Id (2-4094)" ::= { winlink1000OduServiceVlan 5 } winlink1000OduSrvVlanIngressAllowedVIDs OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "ODU ethernet port VLAN IDs that will not be filtered on ingress. w|w|w|w|w|w|w|w| ( where w = {0-4094} and w != 1 )" ::= { winlink1000OduServiceVlan 6 } winlink1000OduSrvVlanDisable OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Disable VLAN functionality. The following values can be set: 3 - Disable ODU & IDU VLAN Configurations." ::= { winlink1000OduServiceVlan 7 } winlink1000OduServiceVlanProviderListTPIDstr OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Holds the possible Provider TPIDs." ::= { winlink1000OduServiceVlan 8 } -- ########################################################### -- DHCP Relay Agent -- ########################################################### winlink1000OduDhcpRelayAgent OBJECT-TYPE SYNTAX INTEGER { disabled (1), enabled (2) } ACCESS read-write STATUS mandatory DESCRIPTION "DHCP Relay Agent Mode" ::= { winlink1000OduService 7 } -- ########################################################### -- ODU User Authentication -- ########################################################### winlink1000OduServiceUserAuthentication OBJECT IDENTIFIER ::= { winlink1000OduService 8 } winlink1000OduServiceUserAuthenticationMode OBJECT-TYPE SYNTAX INTEGER { disable (1), enable (2) } ACCESS read-write STATUS mandatory DESCRIPTION "RADIUS User Authentication Mode - Disable / Enable " ::= { winlink1000OduServiceUserAuthentication 1 } winlink1000OduServiceUserAuthenticationBypassTable OBJECT-TYPE SYNTAX SEQUENCE OF Winlink1000OduServiceUserAuthenticationBypassEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "RADIUS User Authentication Bypass Table" ::= { winlink1000OduServiceUserAuthentication 2 } winlink1000OduServiceUserAuthenticationBypassEntry OBJECT-TYPE SYNTAX Winlink1000OduServiceUserAuthenticationBypassEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "RADIUS User Authentication Table Bypass Entry" INDEX { winlink1000OduServiceUserAuthenticationBypassIndex } ::= { winlink1000OduServiceUserAuthenticationBypassTable 1 } Winlink1000OduServiceUserAuthenticationBypassEntry ::= SEQUENCE { winlink1000OduServiceUserAuthenticationBypassIndex INTEGER, winlink1000OduServiceUserAuthenticationBypassIp IpAddress, winlink1000OduServiceUserAuthenticationBypassNetMask IpAddress } winlink1000OduServiceUserAuthenticationBypassIndex OBJECT-TYPE SYNTAX INTEGER (0..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "RADIUS User Authentication Table Bypass Index" ::= { winlink1000OduServiceUserAuthenticationBypassEntry 1 } winlink1000OduServiceUserAuthenticationBypassIp OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "RADIUS User Authentication Bypass Ip Address" ::= { winlink1000OduServiceUserAuthenticationBypassEntry 2 } winlink1000OduServiceUserAuthenticationBypassNetMask OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "RADIUS User Authentication Bypass Netmask Address" ::= { winlink1000OduServiceUserAuthenticationBypassEntry 3 } winlink1000OduServiceUserAuthenticationRadiusServerTable OBJECT-TYPE SYNTAX SEQUENCE OF Winlink1000OduServiceUserAuthenticationRadiusServerEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Holds the Radius User Authentication Server configurations" ::= { winlink1000OduServiceUserAuthentication 3 } winlink1000OduServiceUserAuthenticationRadiusServerEntry OBJECT-TYPE SYNTAX Winlink1000OduServiceUserAuthenticationRadiusServerEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "HBS User Authentication Radius Server table entry." INDEX { winlink1000OduServiceUserAuthenticationRadiusServerIndex } ::= { winlink1000OduServiceUserAuthenticationRadiusServerTable 1 } Winlink1000OduServiceUserAuthenticationRadiusServerEntry ::= SEQUENCE { winlink1000OduServiceUserAuthenticationRadiusServerIndex INTEGER, winlink1000OduServiceUserAuthenticationRadiusServerIpAddr IpAddress, winlink1000OduServiceUserAuthenticationRadiusServerPort INTEGER, winlink1000OduServiceUserAuthenticationRadiusServerSecret DisplayString, winlink1000OduServiceUserAuthenticationRadiusServerConnectivity INTEGER, winlink1000OduServiceUserAuthenticationRadiusServerNumOfRetries INTEGER, winlink1000OduServiceUserAuthenticationRadiusServerTimeout INTEGER } winlink1000OduServiceUserAuthenticationRadiusServerIndex OBJECT-TYPE SYNTAX INTEGER (0..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "User Authentication Radius Server Table index." ::= { winlink1000OduServiceUserAuthenticationRadiusServerEntry 1 } winlink1000OduServiceUserAuthenticationRadiusServerIpAddr OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "User Authentication Radius Server IP" ::= { winlink1000OduServiceUserAuthenticationRadiusServerEntry 2 } winlink1000OduServiceUserAuthenticationRadiusServerPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "User Authentication Radius Server Port" ::= { winlink1000OduServiceUserAuthenticationRadiusServerEntry 3 } winlink1000OduServiceUserAuthenticationRadiusServerSecret OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "User Authentication Radius Server Secret" ::= { winlink1000OduServiceUserAuthenticationRadiusServerEntry 4 } winlink1000OduServiceUserAuthenticationRadiusServerConnectivity OBJECT-TYPE SYNTAX INTEGER { success (1), noServerResponse (2), noServer (3), testing (4), badSecret (5), timeout (6) } ACCESS read-write STATUS mandatory DESCRIPTION "User Authentication Radius Server connectivity status" ::= { winlink1000OduServiceUserAuthenticationRadiusServerEntry 5 } winlink1000OduServiceUserAuthenticationRadiusServerNumOfRetries OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "User Authentication Radius Server number of retries" ::= { winlink1000OduServiceUserAuthenticationRadiusServerEntry 6 } winlink1000OduServiceUserAuthenticationRadiusServerTimeout OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "User Authentication Radius Server timeout" ::= { winlink1000OduServiceUserAuthenticationRadiusServerEntry 7 } winlink1000OduServiceUserAuthenticationRadiusAccess OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "RADIUS User Authentication Radius Access" ::= { winlink1000OduServiceUserAuthentication 4 } winlink1000OduServiceUserAuthenticationToken OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "RADIUS User Authentication Token" ::= { winlink1000OduServiceUserAuthentication 5 } -- ########################################################### -- ODU ACL -- ########################################################### winlink1000OduServiceAcl OBJECT IDENTIFIER ::= { winlink1000OduService 9 } winlink1000OduServiceAclMode OBJECT-TYPE SYNTAX INTEGER { disable (1), enable (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Acl Mode - Disable / Enable " ::= { winlink1000OduServiceAcl 1 } winlink1000OduServiceAclTable OBJECT-TYPE SYNTAX SEQUENCE OF Winlink1000OduServiceAclEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Acl Table" ::= { winlink1000OduServiceAcl 2 } winlink1000OduServiceAclEntry OBJECT-TYPE SYNTAX Winlink1000OduServiceAclEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Acl Table Entry" INDEX { winlink1000OduServiceAclIndex } ::= { winlink1000OduServiceAclTable 1 } Winlink1000OduServiceAclEntry ::= SEQUENCE { winlink1000OduServiceAclIndex INTEGER, winlink1000OduServiceAclIp IpAddress, winlink1000OduServiceAclNetMask IpAddress } winlink1000OduServiceAclIndex OBJECT-TYPE SYNTAX INTEGER (0..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "Acl Table Index" ::= { winlink1000OduServiceAclEntry 1 } winlink1000OduServiceAclIp OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "Acl Ip Address" ::= { winlink1000OduServiceAclEntry 2 } winlink1000OduServiceAclNetMask OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "Acl Netmask Address" ::= { winlink1000OduServiceAclEntry 3 } -- ########################################################### -- DHCP Relay Agent Circuit ID Source -- ########################################################### winlink1000OduDhcpRelayAgentCircuitIdSource OBJECT-TYPE SYNTAX INTEGER { hbsMacAaddress (1), hbsName (2), hbsSerial (3) } ACCESS read-write STATUS mandatory DESCRIPTION "DHCP Relay Agent Circuit ID Source" ::= { winlink1000OduService 10 } -- ########################################################### -- DHCP Relay Agent Remote ID Source -- ########################################################### winlink1000OduDhcpRelayAgentRemoteIdSource OBJECT-TYPE SYNTAX INTEGER { hsuMacAddress (1), hsuName (2), hsuSerial (3) } ACCESS read-write STATUS mandatory DESCRIPTION "DHCP Relay Agent Remote ID Source" ::= { winlink1000OduService 11 } -- ########################################################### -- DHCP Relay Agent Concatenated Circuit Id Mode -- ########################################################### winlink1000OduDhcpRelayAgentConcatenatedCircuitIdMode OBJECT-TYPE SYNTAX INTEGER { disable (1), enable (2) } ACCESS read-write STATUS mandatory DESCRIPTION "DHCP Relay Agent Concatenated Circuit Id Mode" ::= { winlink1000OduService 12 } -- ########################################################### -- ODU Redundancy -- ########################################################### winlink1000OduServiceRedundancy OBJECT IDENTIFIER ::= { winlink1000OduService 13 } winlink1000OduSrvRedundancyRole OBJECT-TYPE SYNTAX INTEGER { primary (1), secondary (2), none (3) } ACCESS read-write STATUS mandatory DESCRIPTION "Mode of the link regarding Service Redundancy." ::= { winlink1000OduServiceRedundancy 1 } winlink1000OduSrvRedundancyPeerIP OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "Peer IP for 1 plus 1 service one bts is active the other is in standby state." ::= { winlink1000OduServiceRedundancy 2 } winlink1000OduSrvRedundancyCheckPointIP OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "Checkpoint Ip to test network connectivity" ::= { winlink1000OduServiceRedundancy 3 } winlink1000OduSrvRedundancyFailureReason OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "1 plus 1 feature display reason of failure" ::= { winlink1000OduServiceRedundancy 4 } winlink1000OduSrvRedundancyCpeWirelessConnectionTO OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "Wireless Connection Timeout (sec). Applicable at Primary CPE only" ::= { winlink1000OduServiceRedundancy 5 } -- ########################################################### -- ODU Ethernet -- ########################################################### winlink1000OduEthernet OBJECT IDENTIFIER ::= { winlink1000Odu 3 } winlink1000OduEthernetRemainingRate OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Current Ethernet bandwidth in bps." ::= { winlink1000OduEthernet 1 } -- ########################################################### -- ODU Ethernet Interface Table -- ########################################################### winlink1000OduEthernetIfTable OBJECT-TYPE SYNTAX SEQUENCE OF Winlink1000OduEthernetIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "ODU Ethernet Interface table." ::= { winlink1000OduEthernet 2 } winlink1000OduEthernetIfEntry OBJECT-TYPE SYNTAX Winlink1000OduEthernetIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "ODU Ethernet Interface table entry." INDEX { winlink1000OduEthernetIfIndex } ::= { winlink1000OduEthernetIfTable 1 } Winlink1000OduEthernetIfEntry ::= SEQUENCE { winlink1000OduEthernetIfIndex INTEGER, winlink1000OduEthernetIfAddress DisplayString, winlink1000OduEthernetIfAdminStatus INTEGER, winlink1000OduEthernetIfOperStatus INTEGER, winlink1000OduEthernetIfFailAction INTEGER, winlink1000OduEthernetIf1588v2PTPEventRXRate INTEGER, winlink1000OduEthernetIf1588v2PTPEventTXRate INTEGER } winlink1000OduEthernetIfIndex OBJECT-TYPE SYNTAX INTEGER (0..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "ODU Ethernet Interface Index." ::= { winlink1000OduEthernetIfEntry 1 } winlink1000OduEthernetIfAddress OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "ODU MAC address." ::= { winlink1000OduEthernetIfEntry 5 } winlink1000OduEthernetIfAdminStatus OBJECT-TYPE SYNTAX INTEGER { portAutoSense(1), portAutoSense100Mbps(5), forceHalfDuplex10Mbps(10), forceFullDuplex10Mbps(11), forceHalfDuplex100Mbps(15), forceFullDuplex100Mbps(16), forceFullDuplex1000Mbps(21), disablePoePort(254), disablePort(255) } ACCESS read-write STATUS mandatory DESCRIPTION "Required state of the interface." ::= { winlink1000OduEthernetIfEntry 6 } winlink1000OduEthernetIfOperStatus OBJECT-TYPE SYNTAX INTEGER { notConnected(1), connectedHalfDuplex10Mbps(10), connectedFullDuplex10Mbps(11), connectedHalfDuplex100Mbps(15), connectedFullDuplex100Mbps(16), connectedHalfDuplex1000Mbps(20), connectedFullDuplex1000Mbps(21), unknown(65535) } ACCESS read-only STATUS mandatory DESCRIPTION "Current operational state of the interface." ::= { winlink1000OduEthernetIfEntry 7 } winlink1000OduEthernetIfFailAction OBJECT-TYPE SYNTAX INTEGER { faNoAction(1), faForceHalfDuplex10Mbps(10), faForceFullDuplex10Mbps(11), faDisablePort(255) } ACCESS read-write STATUS mandatory DESCRIPTION "Failure action of the interface." ::= { winlink1000OduEthernetIfEntry 8 } winlink1000OduEthernetIf1588v2PTPEventRXRate OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "For debug use" ::= { winlink1000OduEthernetIfEntry 9 } winlink1000OduEthernetIf1588v2PTPEventTXRate OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "For debug use" ::= { winlink1000OduEthernetIfEntry 10 } winlink1000OduEthernetNumOfPorts OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of ODU network interfaces." ::= { winlink1000OduEthernet 3 } winlink1000OduEthernetGbeSupported OBJECT-TYPE SYNTAX INTEGER {notSupported(1), supported(2)} ACCESS read-only STATUS mandatory DESCRIPTION "Supported Giga bit Ethernet in ODU." ::= { winlink1000OduEthernet 4 } winlink1000OduEthernetSfpProperties OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Sfp port properties." ::= { winlink1000OduEthernet 5 } winlink1000OduEthernetMainTrafficPort OBJECT-TYPE SYNTAX INTEGER { lan1(1), lan2(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Ethernet Main Traffic Port." ::= { winlink1000OduEthernet 6 } winlink1000OduEthernetRestartCounter OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Ethernet Restart Counter" ::= { winlink1000OduEthernet 7 } winlink1000OduEthernetSmart100M OBJECT-TYPE SYNTAX INTEGER { disable(1), enable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Ethernet Smart 100M" ::= { winlink1000OduEthernet 8 } -- ########################################################### -- ODU Bridge -- ########################################################### winlink1000OduBridge OBJECT IDENTIFIER ::= { winlink1000Odu 4 } -- ########################################################### -- ODU Bridge Base -- ########################################################### winlink1000OduBridgeBase OBJECT IDENTIFIER ::= { winlink1000OduBridge 1 } -- ########################################################### -- ODU Bridge Ports Table -- ########################################################### winlink1000OduBridgeBasePortTable OBJECT-TYPE SYNTAX SEQUENCE OF Winlink1000OduBridgeBasePortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "ODU Bridge Ports table." ::= { winlink1000OduBridgeBase 4 } winlink1000OduBridgeBasePortEntry OBJECT-TYPE SYNTAX Winlink1000OduBridgeBasePortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "ODU Bridge Ports table entry." INDEX { winlink1000OduBridgeBasePortIndex } ::= { winlink1000OduBridgeBasePortTable 1 } Winlink1000OduBridgeBasePortEntry ::= SEQUENCE { winlink1000OduBridgeBasePortIndex INTEGER, winlink1000OduBridgeBaseIfIndex INTEGER } winlink1000OduBridgeBasePortIndex OBJECT-TYPE SYNTAX INTEGER (0..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "ODU Bridge Port Number." ::= { winlink1000OduBridgeBasePortEntry 1 } winlink1000OduBridgeBaseIfIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "IfIndex corresponding to ODU Bridge port." ::= { winlink1000OduBridgeBasePortEntry 2 } -- ########################################################### -- ODU Bridge Tp -- ########################################################### winlink1000OduBridgeTp OBJECT IDENTIFIER ::= { winlink1000OduBridge 4 } winlink1000OduBridgeTpMode OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "ODU bridge mode. A change is effective after reset. Valid values: hubMode (0), bridgeMode (1)." ::= { winlink1000OduBridgeTp 101 } -- ########################################################### -- ODU Transparent Bridge Ports Table -- ########################################################### winlink1000OduBridgeTpPortTable OBJECT-TYPE SYNTAX SEQUENCE OF Winlink1000OduBridgeTpPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "ODU Transparent Bridge Ports table." ::= { winlink1000OduBridgeTp 3 } winlink1000OduBridgeTpPortEntry OBJECT-TYPE SYNTAX Winlink1000OduBridgeTpPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "ODU Transparent Bridge Ports table entry." INDEX { winlink1000OduBridgeTpPortIndex } ::= { winlink1000OduBridgeTpPortTable 1 } Winlink1000OduBridgeTpPortEntry ::= SEQUENCE { winlink1000OduBridgeTpPortIndex INTEGER, winlink1000OduBridgeTpPortInFrames Counter, winlink1000OduBridgeTpPortOutFrames Counter, winlink1000OduBridgeTpPortInBytes Counter, winlink1000OduBridgeTpPortOutBytes Counter } winlink1000OduBridgeTpPortIndex OBJECT-TYPE SYNTAX INTEGER (0..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "ODU Transparent Bridge Port Number." ::= { winlink1000OduBridgeTpPortEntry 1 } winlink1000OduBridgeTpPortInFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of frames received by this port." ::= { winlink1000OduBridgeTpPortEntry 3 } winlink1000OduBridgeTpPortOutFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of frames transmitted by this port." ::= { winlink1000OduBridgeTpPortEntry 4 } winlink1000OduBridgeTpPortInBytes OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of bytes received by this port." ::= { winlink1000OduBridgeTpPortEntry 101 } winlink1000OduBridgeTpPortOutBytes OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of bytes transmitted by this port." ::= { winlink1000OduBridgeTpPortEntry 102 } winlink1000OduBridgeConfigMode OBJECT-TYPE SYNTAX INTEGER{ enable (1), disable (2) } ACCESS read-only STATUS mandatory DESCRIPTION "ODU bridge configuration mode" ::= { winlink1000OduBridgeTp 102 } -- ########################################################### -- ODU Air -- ########################################################### winlink1000OduAir OBJECT IDENTIFIER ::= { winlink1000Odu 5 } winlink1000OduAirFreq OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Installation Center Frequency. Valid values are product dependent. A change is effective after link re-synchronization." ::= { winlink1000OduAir 1 } winlink1000OduAirDesiredRate OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS deprecated DESCRIPTION "Deprecated parameter, actual behavior is read-only. Required Air Rate. For Channel Bandwidth of 20, 10, 5 MHz divide the value by 1, 2, 4 respectively." ::= { winlink1000OduAir 2 } winlink1000OduAirSSID OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Reserved for the Manager application provided with the product. The Sector ID in Point-To-Multi-Point systems." ::= { winlink1000OduAir 3 } winlink1000OduAirTxPower OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Required Transmit power in dBm . This is a nominal value while the actual transmit power includes additional attenuation. The min and max values are product specific. A change is effective immediately." ::= { winlink1000OduAir 4 } winlink1000OduAirSesState OBJECT-TYPE SYNTAX INTEGER { sessionDown (1), basicRate (2), active (3), installation (4), scanning (5), probing (6), transmitting (7), activeWithDefaultEncryptionKey (8), installationWithDefaultEncryptionKey (9), bitFailed (10), activeWithVersionsMismatch (11), installationWithVersionsMismatch (12), inactive (13), iduIncompatible (14), spectrumAnalysis (15) } ACCESS read-only STATUS mandatory DESCRIPTION "Current Link State. The value is active (3) during normal operation." ::= { winlink1000OduAir 5 } winlink1000OduAirMstrSlv OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This parameter indicates if the device was automatically selected into the radio link master or slave. The value is undefined if there is no link. The value is relevant only for point to point systems." ::= { winlink1000OduAir 6 } winlink1000OduAirResync OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Setting this parameter to 1 will cause the link to restart the synchronization process." ::= { winlink1000OduAir 8 } -- ########################################################### -- ODU Air Perf -- ########################################################### winlink1000OduAirPerf OBJECT IDENTIFIER ::= { winlink1000OduAir 9 } winlink1000OduAirRxPower OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Received Signal Strength in dBm. Relevant only for point to point systems." ::= { winlink1000OduAirPerf 1 } winlink1000OduAirTotalFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of radio frames." ::= { winlink1000OduAirPerf 2 } winlink1000OduAirBadFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of received radio frames with CRC error. The value is relevant only for point to point systems ." ::= { winlink1000OduAirPerf 3 } winlink1000OduAirCurrentRate OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS deprecated DESCRIPTION "Deprecated parameter. Actual rate of the air interface in Mbps. For Channel Bandwidth of 20, 10, 5 MHz divide the value by 1, 2, 4 respectively." ::= { winlink1000OduAirPerf 4 } winlink1000OduAirCurrentRateIdx OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Index of current air rate." ::= { winlink1000OduAirPerf 5 } winlink1000OduAirChainsRxPower OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Received Signal Strength of Cpe chains in dBm. Chain 1 RSS: (1 Byte) Chain 2 RSS: (1 Byte) Chain 3 RSS: (1 Byte)" ::= { winlink1000OduAirPerf 6 } winlink1000OduAirCurrentRateCBW OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "CBW of current air rate." ::= { winlink1000OduAirPerf 7 } winlink1000OduAirCurrentRateGI OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "GI of current air rate." ::= { winlink1000OduAirPerf 8 } winlink1000OduAirTxPower36 OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS deprecated DESCRIPTION "Deprecated parameter. Actual behavior is read-only." ::= { winlink1000OduAir 10 } winlink1000OduAirTxPower48 OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS deprecated DESCRIPTION "Deprecated parameter. Actual behavior is read-only." ::= { winlink1000OduAir 11 } winlink1000OduAirCurrentTxPower OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Current Transmit Power in dBm. This is a nominal value while the actual transmit power includes additional attenuation." ::= { winlink1000OduAir 12 } winlink1000OduAirMinFrequency OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Minimum center frequency in MHz." ::= { winlink1000OduAir 13 } winlink1000OduAirMaxFrequency OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Maximum center frequency in MHz." ::= { winlink1000OduAir 14 } winlink1000OduAirFreqResolution OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Center Frequency resolution. Measured in MHz if value < 100, otherwise in KHz." ::= { winlink1000OduAir 15 } winlink1000OduAirCurrentFreq OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Current Center Frequency. Measured in MHz if center frequency resolution value < 100, otherwise in KHz." ::= { winlink1000OduAir 16 } winlink1000OduAirNumberOfChannels OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of channels that can be used." ::= { winlink1000OduAir 17 } -- ########################################################### -- Channels Table -- ########################################################### winlink1000OduAirChannelsTable OBJECT-TYPE SYNTAX SEQUENCE OF Winlink1000OduAirChannelsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of channels used by automatic channels selection (ACS)." ::= { winlink1000OduAir 18 } winlink1000OduAirChannelsEntry OBJECT-TYPE SYNTAX Winlink1000OduAirChannelsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "ACS channels table entry." INDEX { winlink1000OduAirChannelsIndex } ::= { winlink1000OduAirChannelsTable 1 } Winlink1000OduAirChannelsEntry ::= SEQUENCE { winlink1000OduAirChannelsIndex INTEGER, winlink1000OduAirChannelsFrequency INTEGER, winlink1000OduAirChannelsOperState INTEGER, winlink1000OduAirChannelsAvail INTEGER, winlink1000OduAirChannelsDefaultFreq INTEGER } winlink1000OduAirChannelsIndex OBJECT-TYPE SYNTAX INTEGER (0..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "Channel Index." ::= { winlink1000OduAirChannelsEntry 1 } winlink1000OduAirChannelsFrequency OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Channel frequency in MHz." ::= { winlink1000OduAirChannelsEntry 2 } winlink1000OduAirChannelsOperState OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Channel state. Can be set by the user. Automatic Channel Selection uses channels that are AirChannelsOperState enabled and AirChannelsAvail enabled. A change is effective after link re-synchronization. Valid values: disabled (0), enabled (1). Rewriteable only in Point-To-Point products." ::= { winlink1000OduAirChannelsEntry 3 } winlink1000OduAirChannelsAvail OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Channel state. Product specific and cannot be changed by the user. Automatic Channel Selection uses channels that are AirChannelsOperState enabled and AirChannelsAvail enabled. Valid values: disabled (0), enabled (1)." ::= { winlink1000OduAirChannelsEntry 4 } winlink1000OduAirChannelsDefaultFreq OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Default channel's availability for all CBWs. The valid values are: forbidden (0), available (1)." ::= { winlink1000OduAirChannelsEntry 5 } winlink1000OduAirDfsState OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Radar detection state. Valid values: disabled (0), enabled (1)." ::= { winlink1000OduAir 19 } winlink1000OduAirAutoChannelSelectionState OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS deprecated DESCRIPTION "Deprecated parameter. Indicating Automatic Channel Selection availability at current channel bandwidth. Valid values: disabled (0), enabled (1)." ::= { winlink1000OduAir 20 } winlink1000OduAirEnableTxPower OBJECT-TYPE SYNTAX INTEGER { enabled (1), disabled (2) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicating Transmit power configuration enabled or disabled." ::= { winlink1000OduAir 21 } winlink1000OduAirMinTxPower OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Minimum Transmit power in dBm." ::= { winlink1000OduAir 22 } -- ########################################################### -- Max Tx Power Table -- ########################################################### winlink1000OduAirMaxTxPowerTable OBJECT-TYPE SYNTAX SEQUENCE OF Winlink1000OduAirMaxTxPowerEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of Maximum transmit power per air rate, in dBm." ::= { winlink1000OduAir 23 } winlink1000OduAirMaxTxPowerEntry OBJECT-TYPE SYNTAX Winlink1000OduAirMaxTxPowerEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Maximum Transmit power table entry." INDEX { winlink1000OduAirMaxTxPowerIndex } ::= { winlink1000OduAirMaxTxPowerTable 1 } Winlink1000OduAirMaxTxPowerEntry ::= SEQUENCE { winlink1000OduAirMaxTxPowerIndex INTEGER, winlink1000OduAirMaxTxPower INTEGER } winlink1000OduAirMaxTxPowerIndex OBJECT-TYPE SYNTAX INTEGER (0..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "Air interface rate index." ::= { winlink1000OduAirMaxTxPowerEntry 1 } winlink1000OduAirMaxTxPower OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Maximum Transmit power in dBm." ::= { winlink1000OduAirMaxTxPowerEntry 2 } winlink1000OduAirChannelBandwidth OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Channel bandwidth in KHz. A change is effective after reset." ::= { winlink1000OduAir 24 } -- ########################################################### -- Channel BW Table -- ########################################################### winlink1000OduAirChannelBWTable OBJECT-TYPE SYNTAX SEQUENCE OF Winlink1000OduAirChannelBWEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Channel Bandwidths table." ::= { winlink1000OduAir 25 } winlink1000OduAirChannelBWEntry OBJECT-TYPE SYNTAX Winlink1000OduAirChannelBWEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Channel Bandwidth table entry." INDEX { winlink1000OduAirChannelBWIndex } ::= { winlink1000OduAirChannelBWTable 1 } Winlink1000OduAirChannelBWEntry ::= SEQUENCE { winlink1000OduAirChannelBWIndex INTEGER, winlink1000OduAirChannelBWAvail INTEGER, winlink1000OduAirChannelsAdminState DisplayString, winlink1000OduAirChannelBWHSSATDDConflictPerCBW INTEGER, winlink1000OduAirChannelBWMinRatioForSupporting INTEGER, winlink1000OduAirChannelBWMaxRatioForSupporting INTEGER } winlink1000OduAirChannelBWIndex OBJECT-TYPE SYNTAX INTEGER { channelBW5MHz(1), channelBW10MHz(2), channelBW20MHz(3), channelBW40MHz(4), channelBW80MHz(5), channelBW7MHz(6), channelBW14MHz(7) } ACCESS read-only STATUS mandatory DESCRIPTION "Channel Bandwidth index." ::= { winlink1000OduAirChannelBWEntry 1 } winlink1000OduAirChannelBWAvail OBJECT-TYPE SYNTAX INTEGER { notSupported(1), supportedManual(2), supportedWithACS(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Channel Bandwidth availability, product specific. Options are: Not supported, supported with manual channel selection, supported with Automatic Channel Selection." ::= { winlink1000OduAirChannelBWEntry 2 } winlink1000OduAirChannelsAdminState OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Channels' availability per CBW." ::= { winlink1000OduAirChannelBWEntry 3 } winlink1000OduAirChannelBWHSSATDDConflictPerCBW OBJECT-TYPE SYNTAX INTEGER { noConflict(1), conflictSingle(2), conflictDual(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Indication for possible Link drop per CBW due to conflict between HSS and ATDD." ::= { winlink1000OduAirChannelBWEntry 4 } winlink1000OduAirChannelBWMinRatioForSupporting OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Minimal TX ratio that may be used by the HSM and still enable proper operation of the aforementioned CBW." ::= { winlink1000OduAirChannelBWEntry 5 } winlink1000OduAirChannelBWMaxRatioForSupporting OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Maximal TX ratio that may be used by the HSM and still enable proper operation of the aforementioned CBW." ::= { winlink1000OduAirChannelBWEntry 6 } winlink1000OduAirRFD OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Current radio frame duration in microseconds." ::= { winlink1000OduAir 26 } -- ########################################################### -- Available Rates Table -- ########################################################### winlink1000OduAirRatesTable OBJECT-TYPE SYNTAX SEQUENCE OF Winlink1000OduAirRatesEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Air Rate indexes table for current channel bandwidth." ::= { winlink1000OduAir 27 } winlink1000OduAirRatesEntry OBJECT-TYPE SYNTAX Winlink1000OduAirRatesEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Air Rate indexes table entry." INDEX { winlink1000OduAirRatesIndex } ::= { winlink1000OduAirRatesTable 1 } Winlink1000OduAirRatesEntry ::= SEQUENCE { winlink1000OduAirRatesIndex INTEGER, winlink1000OduAirRatesAvail INTEGER } winlink1000OduAirRatesIndex OBJECT-TYPE SYNTAX INTEGER (0..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "Air Rate index." ::= { winlink1000OduAirRatesEntry 1 } winlink1000OduAirRatesAvail OBJECT-TYPE SYNTAX INTEGER { rateNotAvailable(1), rateAvailable(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Air Rate availability, depending on air interface conditions." ::= { winlink1000OduAirRatesEntry 2 } winlink1000OduAirDesiredRateIdx OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Required Air Rate index. 0 reserved for Adaptive Rate. A change is effective immediately after Set operation to the master side while the link is up." ::= { winlink1000OduAir 28 } winlink1000OduAirLinkDistance OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Link distance in meters. A value of -1 indicates an illegal value and is also used when a link is not established." ::= { winlink1000OduAir 29 } winlink1000OduAirLinkWorkingMode OBJECT-TYPE SYNTAX INTEGER { unknown(1), normal(2), fullCompatibilityRemoteUpgradeAvailable(3), fullCompatibilityLocalUpgradeAvailable(4), restrictedCompatibilityRemoteUpgradeRecomended(5), restrictedCompatibilityLocalUpgradeRecomended(6), softwareUpgradeRemoteUpgradeRequired(7), softwareUpgradeLocalUpgradeRequired(8), versionsIncompatibilityRemoteUpgradeRequired(9), versionsIncompatibilityLocalUpgradeRequired(10) } ACCESS read-only STATUS mandatory DESCRIPTION "Link working mode as a result of comparing versions of both sides of the link. Possible modes are: Unknown - no link, Normal - versions on both sides are identical with full compatibility, with restricted compatibility, or versions on both sides are different with software upgrade or versions incompatibility." ::= { winlink1000OduAir 30 } winlink1000OduAirMajorLinkIfVersion OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Major link interface version" ::= { winlink1000OduAir 31 } winlink1000OduAirMinorLinkIfVersion OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Minor link interface version" ::= { winlink1000OduAir 32 } winlink1000OduAirHss OBJECT IDENTIFIER ::= { winlink1000OduAir 40 } winlink1000OduAirHssDesiredOpState OBJECT-TYPE SYNTAX INTEGER { notSupported(1), independentUnit(2), hubSyncMaster(3), hubSyncClientContinueTx(4), hubSyncClientDisableTx(5), gpsSync(6), independentSyncUnit-ISU(7) } ACCESS read-write STATUS mandatory DESCRIPTION "Required Hub Site Synchronization operating state. For HssSyncUnits : For hssISU :[2,7] ,For hssGSU :[2,6] For HBS: [2,3,4,5]" ::= { winlink1000OduAirHss 1 } winlink1000OduAirHssCurrentOpState OBJECT-TYPE SYNTAX INTEGER { notSupported(1), independentUnit(2), hubSyncMaster(3), hubSyncClientContinueTx(4), hubSyncClientDisableTx(5), gpsSync(6), independentSyncUnit-ISU(7) } ACCESS read-only STATUS mandatory DESCRIPTION "Current Hub Site Synchronization operating state." ::= { winlink1000OduAirHss 2 } winlink1000OduAirHssSyncStatus OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), notSynchronized(2), synchronized(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Hub Site Synchronization sync status." ::= { winlink1000OduAirHss 3 } winlink1000OduAirHssExtPulseStatus OBJECT-TYPE SYNTAX INTEGER { notDetected(1), generating(2), generatingAndDetected(3), generatingAndImproperDetected(4), detected(5), improperDetected(6), multipleSourcesDetected(7) } ACCESS read-only STATUS mandatory DESCRIPTION "Hub Site Synchronization external pulse detection status. In GSS mode: if generating then 1PSP is auto generated by the GSS Unit. if generatingAndDetecting then 1PSP is generated by GPS satellites signal." ::= { winlink1000OduAirHss 4 } winlink1000OduAirHssExtPulseType OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), typeA(2), typeB(3), typeC(4), typeD(5), typeE(6), typeF(7) } ACCESS read-only STATUS mandatory DESCRIPTION "Hub Site Synchronization external pulse type." ::= { winlink1000OduAirHss 5 } winlink1000OduAirHssDesiredExtPulseType OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), typeA(2), typeB(3), typeC(4), typeD(5), typeE(6), typeF(7) } ACCESS read-write STATUS mandatory DESCRIPTION "Hub Site Synchronization required external pulse type. Valid values for read write: {typeA(2),typeB(3),typeC(4),typeD(5),typeE(6),typeF(7)}. Valid value for read only: {notApplicable(1)}." ::= { winlink1000OduAirHss 6 } -- ########################################################### -- HSS Radio Frame Pattern Table -- ########################################################### winlink1000OduAirHssRfpTable OBJECT-TYPE SYNTAX SEQUENCE OF Winlink1000OduAirHssRfpEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "ODU Radio Frame Patterns (RFP) Table." ::= { winlink1000OduAirHss 7 } winlink1000OduAirHssRfpEntry OBJECT-TYPE SYNTAX Winlink1000OduAirHssRfpEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "ODU RFP Table entry." INDEX { winlink1000OduAirHssRfpIndex } ::= { winlink1000OduAirHssRfpTable 1 } Winlink1000OduAirHssRfpEntry ::= SEQUENCE { winlink1000OduAirHssRfpIndex INTEGER, winlink1000OduAirHssRfpEthChannelBW5MHz INTEGER, winlink1000OduAirHssRfpTdmChannelBW5MHz INTEGER, winlink1000OduAirHssRfpEthChannelBW10MHz INTEGER, winlink1000OduAirHssRfpTdmChannelBW10MHz INTEGER, winlink1000OduAirHssRfpEthChannelBW20MHz INTEGER, winlink1000OduAirHssRfpTdmChannelBW20MHz INTEGER, winlink1000OduAirHssRfpEthChannelBW40MHz INTEGER, winlink1000OduAirHssRfpTdmChannelBW40MHz INTEGER, winlink1000OduAirHssRfpEthChannelBW80MHz INTEGER, winlink1000OduAirHssRfpEthChannelBW7MHz INTEGER, winlink1000OduAirHssRfpEthChannelBW14MHz INTEGER } winlink1000OduAirHssRfpIndex OBJECT-TYPE SYNTAX INTEGER (2..7) ACCESS read-only STATUS mandatory DESCRIPTION "ODU RFP Table index. The index represent the Radio Frame Pattern: typeA(2), typeB(3), typeC(4), typeD(5),typeE(6),typeF(7)." ::= { winlink1000OduAirHssRfpEntry 1 } winlink1000OduAirHssRfpEthChannelBW5MHz OBJECT-TYPE SYNTAX INTEGER { bestFit(1), nonOptimal(2), notAvailable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Represents the compatibility of Ethernet service under Channel BW of 5MHz in the specific Radio Frame Pattern." ::= { winlink1000OduAirHssRfpEntry 2 } winlink1000OduAirHssRfpTdmChannelBW5MHz OBJECT-TYPE SYNTAX INTEGER { bestFit(1), nonOptimal(2), notAvailable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Represents the compatibility of TDM service under Channel BW of 5MHz in the specific Radio Frame Pattern." ::= { winlink1000OduAirHssRfpEntry 3 } winlink1000OduAirHssRfpEthChannelBW10MHz OBJECT-TYPE SYNTAX INTEGER { bestFit(1), nonOptimal(2), notAvailable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Represents the compatibility of Ethernet service under Channel BW of 10MHz in the specific Radio Frame Pattern." ::= { winlink1000OduAirHssRfpEntry 4 } winlink1000OduAirHssRfpTdmChannelBW10MHz OBJECT-TYPE SYNTAX INTEGER { bestFit(1), nonOptimal(2), notAvailable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Represents the compatibility of TDM service under Channel BW of 10MHz in the specific Radio Frame Pattern." ::= { winlink1000OduAirHssRfpEntry 5 } winlink1000OduAirHssRfpEthChannelBW20MHz OBJECT-TYPE SYNTAX INTEGER { bestFit(1), nonOptimal(2), notAvailable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Represents the compatibility of Ethernet service under Channel BW of 20MHz in the specific Radio Frame Pattern." ::= { winlink1000OduAirHssRfpEntry 6 } winlink1000OduAirHssRfpTdmChannelBW20MHz OBJECT-TYPE SYNTAX INTEGER { bestFit(1), nonOptimal(2), notAvailable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Represents the compatibility of TDM service under Channel BW of 20MHz in the specific Radio Frame Pattern." ::= { winlink1000OduAirHssRfpEntry 7 } winlink1000OduAirHssRfpEthChannelBW40MHz OBJECT-TYPE SYNTAX INTEGER { bestFit(1), nonOptimal(2), notAvailable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Represents the compatibility of Ethernet service under Channel BW of 40MHz in the specific Radio Frame Pattern." ::= { winlink1000OduAirHssRfpEntry 8 } winlink1000OduAirHssRfpTdmChannelBW40MHz OBJECT-TYPE SYNTAX INTEGER { bestFit(1), nonOptimal(2), notAvailable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Represents the compatibility of TDM service under Channel BW of 40MHz in the specific Radio Frame Pattern." ::= { winlink1000OduAirHssRfpEntry 9 } winlink1000OduAirHssRfpEthChannelBW80MHz OBJECT-TYPE SYNTAX INTEGER { bestFit(1), nonOptimal(2), notAvailable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Represents the compatibility of Ethernet service under Channel BW of 80MHz in the specific Radio Frame Pattern." ::= { winlink1000OduAirHssRfpEntry 10 } winlink1000OduAirHssRfpEthChannelBW7MHz OBJECT-TYPE SYNTAX INTEGER { bestFit(1), nonOptimal(2), notAvailable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Represents the compatibility of Ethernet service under Channel BW of 7MHz in the specific Radio Frame Pattern." ::= { winlink1000OduAirHssRfpEntry 11 } winlink1000OduAirHssRfpEthChannelBW14MHz OBJECT-TYPE SYNTAX INTEGER { bestFit(1), nonOptimal(2), notAvailable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Represents the compatibility of Ethernet service under Channel BW of 14MHz in the specific Radio Frame Pattern." ::= { winlink1000OduAirHssRfpEntry 12 } winlink1000OduAirHssRfpStr OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Hub Site Synchronization supported patterns" ::= { winlink1000OduAirHss 8 } winlink1000OduAirHssHsmID OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A unique ID which is common to the HSM and all its collocated ODUs" ::= { winlink1000OduAirHss 9 } winlink1000OduAirHssTime OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Hub Site Synchronization GPS time" ::= { winlink1000OduAirHss 10 } winlink1000OduAirHssLatitude OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Hub Site Synchronization GPS Latitude" ::= { winlink1000OduAirHss 11 } winlink1000OduAirHssNSIndicator OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Hub Site Synchronization GPS N/S Indicator" ::= { winlink1000OduAirHss 12 } winlink1000OduAirHssLongitude OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Hub Site Synchronization GPS Longitude" ::= { winlink1000OduAirHss 13 } winlink1000OduAirHssEWIndicator OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Hub Site Synchronization GPS E/W Indicator" ::= { winlink1000OduAirHss 14 } winlink1000OduAirHssNumSatellites OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Hub Site Synchronization GPS Number of satellites" ::= { winlink1000OduAirHss 15 } winlink1000OduAirHssAltitude OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Hub Site Synchronization GPS Altitude" ::= { winlink1000OduAirHss 16 } winlink1000OduAirHssRfpPhase OBJECT-TYPE SYNTAX INTEGER { rfpNormalPhase(1), rfpShiftedPhase(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Hub Site Synchronization GPS RFP phase" ::= { winlink1000OduAirHss 17 } winlink1000OduAirHssInterSiteSynchronizationMode OBJECT-TYPE SYNTAX INTEGER { independent(1), synchronized(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Inter-Site Synchronization Mode - independent / synchronized" ::= { winlink1000OduAirHss 18 } winlink1000OduAirHssInterSiteSynchronizationAvailability OBJECT-TYPE SYNTAX INTEGER { notAvailable(1), available(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Inter-Site Synchronization Availability" ::= { winlink1000OduAirHss 19 } winlink1000OduAirHssSatellitesSatSyncRequired OBJECT-TYPE SYNTAX INTEGER { notRequired(1), required(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Satellites Synchronization Is Required" ::= { winlink1000OduAirHss 20 } winlink1000OduAirHssDomainID OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "EHSS domain. Indentify set of CUs with same HSS synchronization" ::= { winlink1000OduAirHss 21 } winlink1000OduAirHssSupportedSynchronizationProtocol OBJECT-TYPE SYNTAX INTEGER { serialOnly(1), ethOnly(2), both(3), ghssAndEth(4), ghssEthSerial(5), ghssOnly(6) } ACCESS read-only STATUS mandatory DESCRIPTION "Supported Synchronization Protocols" ::= { winlink1000OduAirHss 22 } winlink1000OduAirHssDesiredSynchronizationProtocol OBJECT-TYPE SYNTAX INTEGER { serialOnly(1), ethOnly(2), both(3), ghssOnly(4) } ACCESS read-write STATUS mandatory DESCRIPTION "Desired Synchronization Protocols" ::= { winlink1000OduAirHss 23 } winlink1000OduAirHssDiscover OBJECT-TYPE SYNTAX INTEGER { startAll(1), startAllMstr(2), startMyDmn(3), startMyMstr(4) } ACCESS read-write STATUS mandatory DESCRIPTION "Initiate Discovery process of ODUs on the network." ::= { winlink1000OduAirHss 24 } winlink1000OduAirHssNumberOfDiscoveredODUs OBJECT-TYPE SYNTAX INTEGER (0..1000) ACCESS read-only STATUS mandatory DESCRIPTION "Number OF Discovered ODUs in network." ::= { winlink1000OduAirHss 25 } -- ########################################################### -- HSS Discover Table -- ########################################################### winlink1000OduAirHssDiscoverTable OBJECT-TYPE SYNTAX SEQUENCE OF Winlink1000OduAirHssDiscoverEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "HSS Discover Table." ::= { winlink1000OduAirHss 26 } winlink1000OduAirHssDiscoverEntry OBJECT-TYPE SYNTAX Winlink1000OduAirHssDiscoverEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "ODU Discover Table entry." INDEX { winlink1000OduAirHssDiscoverIndex } ::= { winlink1000OduAirHssDiscoverTable 1 } Winlink1000OduAirHssDiscoverEntry ::= SEQUENCE { winlink1000OduAirHssDiscoverIndex INTEGER, winlink1000OduAirHssDiscoverODUDescription DisplayString } winlink1000OduAirHssDiscoverIndex OBJECT-TYPE SYNTAX INTEGER (1..256) ACCESS read-only STATUS mandatory DESCRIPTION "HSS Discover Table Index." ::= { winlink1000OduAirHssDiscoverEntry 1 } winlink1000OduAirHssDiscoverODUDescription OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Hold ODU HSS status in compress format: Domain,IP,HSS Role,Hss support, Enabled HSS protocol,Sync Status, Location, IPv6." ::= { winlink1000OduAirHssDiscoverEntry 2 } -- ###################### End of Discover Table ################### winlink1000OduAirHssMasterSlaveCompatibility OBJECT-TYPE SYNTAX INTEGER { compatible(1), notCompatible(2) } ACCESS read-only STATUS mandatory DESCRIPTION "EHSM version compatibility. Relevant to Ethernet HSS Clients only." ::= { winlink1000OduAirHss 27 } winlink1000OduAirHssNumberOfAssociatedCU OBJECT-TYPE SYNTAX INTEGER (0..256) ACCESS read-only STATUS mandatory DESCRIPTION "Number of associated Ethernet HSS Clients. Relevant to Ethernet HSS Masters only" ::= { winlink1000OduAirHss 28 } -- ########################################################### -- HSS Associated CU Table -- ########################################################### winlink1000OduAirHssAssociatedCUTable OBJECT-TYPE SYNTAX SEQUENCE OF Winlink1000OduAirHssAssociatedCUTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Associated Ethernet HSS Clients Table. Releant for Ethernet HSS Masters only." ::= { winlink1000OduAirHss 29 } winlink1000OduAirHssAssociatedCUTableEntry OBJECT-TYPE SYNTAX Winlink1000OduAirHssAssociatedCUTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Associated Ethernet HSS Clients Table Entry. Releant for Ethernet HSS Masters only." INDEX { winlink1000OduAirHssAssociatedCUIndex } ::= { winlink1000OduAirHssAssociatedCUTable 1 } Winlink1000OduAirHssAssociatedCUTableEntry ::= SEQUENCE { winlink1000OduAirHssAssociatedCUIndex INTEGER, winlink1000OduAirHssAssociatedCUDescription DisplayString } winlink1000OduAirHssAssociatedCUIndex OBJECT-TYPE SYNTAX INTEGER (1..256) ACCESS read-only STATUS mandatory DESCRIPTION "Associated Ethernet HSS Clients Table Index. Releant for Ethernet HSS Masters only." ::= { winlink1000OduAirHssAssociatedCUTableEntry 1 } winlink1000OduAirHssAssociatedCUDescription OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Holds Associated Ethernet HSS Clients Description in compress format: IP,Delay,Compatibility,Ethernet Speed, Ethernet Rx rate, IPv6" ::= { winlink1000OduAirHssAssociatedCUTableEntry 2 } -- ###################### End of Associated CU Table ################### winlink1000OduAirHssSyncStatusEth OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), notSynchronized(2), goodSynchronizationLevel(3), mediumSynchronizationLevel(4), badSynchronizationLevel(5), startSynchronization(6) } ACCESS read-only STATUS mandatory DESCRIPTION "Ethernet HSS Client Synchronization Level" ::= { winlink1000OduAirHss 30 } winlink1000OduAirHssEthVLANTag OBJECT-TYPE SYNTAX INTEGER (1..40947) ACCESS read-write STATUS mandatory DESCRIPTION "Ethernet HSS VLan Tag: The least significate decimal digit is the VLan Priority(0-6) and the rest of the digits represents VLan ID (2-4094)" ::= { winlink1000OduAirHss 31 } winlink1000OduAirHssHSMIPAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "HSMs IP address. Relevant for HSC synchronized over Ethernet." ::= { winlink1000OduAirHss 32 } winlink1000OduAirHssDelayToHSM OBJECT-TYPE SYNTAX INTEGER (0..1000000) ACCESS read-only STATUS mandatory DESCRIPTION "Delay in microseconds to HSM. Relevant for HSC synchronized over Ethernet." ::= { winlink1000OduAirHss 33 } winlink1000OduAirHssSyncAcquisitionSeconds OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Accumulated quantity of seconds in clock acquisition while connected to current HSM" ::= { winlink1000OduAirHss 34 } winlink1000OduAirHssHSMIPv6Address OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "HSMs IPv6 address. Relevant for HSC synchronized over Ethernet." ::= { winlink1000OduAirHss 35 } winlink1000OduAirHssTcMode OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "TC Mode" ::= { winlink1000OduAirHss 36 } winlink1000OduAirHssGpsUncertainty OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "GPS Horizontal Location Uncertainty In Meters" ::= { winlink1000OduAirHss 37 } winlink1000OduAirHssDelayAdaptationEnable OBJECT-TYPE SYNTAX INTEGER{ enable(1), disable(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Delay Adaptation Enable" ::= { winlink1000OduAirHss 38 } -- ###################### End of HSS Section ################### winlink1000OduAirLockRemote OBJECT-TYPE SYNTAX INTEGER { unlock(1), lock(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This parameter enables locking the link with a specific ODU. The following values can be set: Unlock (default) - The ODU is not locked on a specific remote ODU. Unlock can only be performed when the link is not connected. Lock - The ODU is locked on a specific remote ODU. Lock can only be performed when the link is active." ::= { winlink1000OduAir 41 } winlink1000OduAirAntennaGain OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Current Antenna Gain in 0.1 dBi resolution. User defined value for external antenna. Legal range: MinAntennaGain100). If list is empty, no scan is done." ::= { winlink1000OduAir 77 } winlink1000OduAirInterfaceUtilizationSupport OBJECT-TYPE SYNTAX INTEGER { fullSupport(1), partialSupport(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Support Air Interface Utilization: BTS: 1 = Full Support - all the CPEs support Air Interface Utilization. 2 = Partial Support - some of the CPEs not support Air Interface Utilization. CPE: 1 = Support Air Interface Utilization. This MIB doesn't exist if the device not support Air Interface Utilization." ::= { winlink1000OduAir 78 } -- ########################################################### -- ODU Carrier Table -- ########################################################### winlink1000OduAirCarrierTable OBJECT-TYPE SYNTAX SEQUENCE OF Winlink1000OduAirCarrierEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Carrier-specific attributes that are not band-specific" ::= { winlink1000OduAir 79 } winlink1000OduAirCarrierEntry OBJECT-TYPE SYNTAX Winlink1000OduAirCarrierEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Carrier table entry." INDEX { winlink1000OduAirCarrierIndex } ::= { winlink1000OduAirCarrierTable 1 } Winlink1000OduAirCarrierEntry ::= SEQUENCE { winlink1000OduAirCarrierIndex INTEGER, winlink1000OduAirCarrierAntennaDescription DisplayString, winlink1000OduAirCarrierDesiredTxPower INTEGER, winlink1000OduAirCarrierResync INTEGER, winlink1000OduAirCarrierCurrentTxPower INTEGER, winlink1000OduAirCarrierCurrentFreq INTEGER, winlink1000OduAirCarrierChannelBandwidth INTEGER, winlink1000OduAirCarrierTotalTxPower INTEGER, winlink1000OduAirCarrierSubBand INTEGER, winlink1000OduAirCarrierComboSubBandTableIndex INTEGER, winlink1000OduAirCarrierAntennaGain INTEGER, winlink1000OduAirCarrierFeederLoss INTEGER, winlink1000OduAirCarrierMaxEirp INTEGER, winlink1000OduAirCarrierAllowableChannelsStr DisplayString, winlink1000OduAirCarrierUCBPSharingPercentage INTEGER, winlink1000OduAirCarrierUCBPMinCS INTEGER, winlink1000OduAirCarrierTvwsOccupiedTvChannels DisplayString, winlink1000OduAirCarrierFrequencyHoppingSequence INTEGER } winlink1000OduAirCarrierIndex OBJECT-TYPE SYNTAX INTEGER { carrier1(1), carrier2(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Carrier index." ::= { winlink1000OduAirCarrierEntry 1 } winlink1000OduAirCarrierAntennaDescription OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The is a description of the antenna connected to the ODU" ::= { winlink1000OduAirCarrierEntry 2 } winlink1000OduAirCarrierDesiredTxPower OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Required Transmit power in dBm . This is a nominal value while the actual transmit power includes additional attenuation. The min and max values are product specific. A change is effective immediately." ::= { winlink1000OduAirCarrierEntry 3 } winlink1000OduAirCarrierResync OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Setting this parameter to 1 will cause the link to restart the synchronization process." ::= { winlink1000OduAirCarrierEntry 4 } winlink1000OduAirCarrierCurrentTxPower OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Current Transmit Power in dBm. This is a nominal value while the actual transmit power includes additional attenuation." ::= { winlink1000OduAirCarrierEntry 5 } winlink1000OduAirCarrierCurrentFreq OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Current Center Frequency. Measured in MHz if center frequency resolution value < 100, otherwise in KHz." ::= { winlink1000OduAirCarrierEntry 6 } winlink1000OduAirCarrierChannelBandwidth OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Channel bandwidth in KHz. A change is effective after reset." ::= { winlink1000OduAirCarrierEntry 7 } winlink1000OduAirCarrierTotalTxPower OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Total Transmit Power in dBm. This is a nominal value While the actual transmit power includes additional attenuation." ::= { winlink1000OduAirCarrierEntry 8 } winlink1000OduAirCarrierSubBand OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Current Frequency Band Id Number." ::= { winlink1000OduAirCarrierEntry 9 } winlink1000OduAirCarrierComboSubBandTableIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Index to the Combo table entry currently used" ::= { winlink1000OduAirCarrierEntry 10 } winlink1000OduAirCarrierAntennaGain OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Current Antenna Gain in 0.1 dBi resolution. User defined value for external antenna. Legal range: MinAntennaGain||" ::= { winlink1000OduAirCarrierEntry 17 } winlink1000OduAirCarrierFrequencyHoppingSequence OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "This parameter is applicable only in frequency hopping mode The sequencee number can be any number between 1 and the number of selected frequencies" ::= { winlink1000OduAirCarrierEntry 18 } winlink1000OduAirAntennaHeight OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Antenna height above ground level in meter" ::= { winlink1000OduAir 80 } winlink1000OduAirAntennaHeightUncertainty OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Uncertainty in meters of antenna height" ::= { winlink1000OduAir 81 } winlink1000OduAirTvwsMinTvChannelIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The current regulation first TV Channel Index" ::= { winlink1000OduAir 82 } winlink1000OduAirTvwsOpTable OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "List of EIRP limit per TV channel from Database" ::= { winlink1000OduAir 83 } winlink1000OduAirTvwsRulesetParams OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Ruleset Parameters for TVWS Product" ::= { winlink1000OduAir 84 } winlink1000OduAirFrequrencyHoppingPassword OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "This parameter is applicable only in frequency hopping mode The password should x to y ascii characters Setting at the base station will apply to all connected subscriber units Setting to subscriber unit can be applied only when not connected." ::= { winlink1000OduAir 85 } -- ########################################################### -- ODU Perf Monitor -- ########################################################### winlink1000OduPerfMon OBJECT IDENTIFIER ::= { winlink1000Odu 6 } -- ########################################################### -- PM Current Table -- ########################################################### winlink1000OduPerfMonCurrTable OBJECT-TYPE SYNTAX SEQUENCE OF Winlink1000OduPerfMonCurrEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table defines/keeps the counters of the current 15 min interval." ::= { winlink1000OduPerfMon 1 } winlink1000OduPerfMonCurrEntry OBJECT-TYPE SYNTAX Winlink1000OduPerfMonCurrEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This is an entry in the Current Interval Table." INDEX {ifIndex } ::= { winlink1000OduPerfMonCurrTable 1 } Winlink1000OduPerfMonCurrEntry ::= SEQUENCE { winlink1000OduPerfMonCurrUAS Gauge, winlink1000OduPerfMonCurrES Gauge, winlink1000OduPerfMonCurrSES Gauge, winlink1000OduPerfMonCurrBBE Gauge, winlink1000OduPerfMonCurrIntegrity INTEGER, winlink1000OduPerfMonCurrCompressed OCTET STRING } winlink1000OduPerfMonCurrUAS OBJECT-TYPE SYNTAX Gauge (0..900) ACCESS read-only STATUS mandatory DESCRIPTION " The current number of Unavailable Seconds starting from the present 15 minutes period." ::= { winlink1000OduPerfMonCurrEntry 1 } winlink1000OduPerfMonCurrES OBJECT-TYPE SYNTAX Gauge (0..900) ACCESS read-only STATUS mandatory DESCRIPTION "Current number of Errored Seconds starting from the present 15 minutes period." ::= { winlink1000OduPerfMonCurrEntry 2 } winlink1000OduPerfMonCurrSES OBJECT-TYPE SYNTAX Gauge (0..900) ACCESS read-only STATUS mandatory DESCRIPTION "Current number of Severely Errored Seconds starting from the present 15 minutes period." ::= { winlink1000OduPerfMonCurrEntry 3 } winlink1000OduPerfMonCurrBBE OBJECT-TYPE SYNTAX Gauge (0..1800000) ACCESS read-only STATUS mandatory DESCRIPTION "Current number of Background Block Errors starting from the present 15 minutes period." ::= { winlink1000OduPerfMonCurrEntry 4 } winlink1000OduPerfMonCurrIntegrity OBJECT-TYPE SYNTAX INTEGER { true(1), false(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the integrity of the entry." ::= { winlink1000OduPerfMonCurrEntry 5 } winlink1000OduPerfMonCurrCompressed OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Holds a compressed string of all data per interface. Compressed Air Interface Structure (size in brackets): UAS (4), ES (4), SES (4), BBE (4), Integrity (1), MinRSL (1), MaxRSL (1), RSLThresh1Exceeded (4), RSLThresh2Exceeded (4), MinTSL (1), MaxTSL (1), TSLThresh1Exceed (4), BBERThresh1Exceed (4), RxMBytes (4) TxMBytes (4), EthCapacityThreshUnder (4), HighTrafficThreshExceed (4) Compressed Etherent ODU interface (size in brackets): UAS (4), ES (4), SES (4), BBE (4), Integrity (1), RxMBytes (4), TxMBytes (4), EthCapacityThreshUnder (4), HighTrafficThreshExceed (4), ActiveSeconds (4) " ::= { winlink1000OduPerfMonCurrEntry 6} -- ########################################################### -- PM Interval Table -- ########################################################### winlink1000OduPerfMonIntervalTable OBJECT-TYPE SYNTAX SEQUENCE OF Winlink1000OduPerfMonIntervalEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table defines/keeps the counters of the last day (in resolution of 15 min intervals)." ::= { winlink1000OduPerfMon 2 } winlink1000OduPerfMonIntervalEntry OBJECT-TYPE SYNTAX Winlink1000OduPerfMonIntervalEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This is an entry in the Interval Table." INDEX {ifIndex, winlink1000OduPerfMonIntervalIdx } ::= { winlink1000OduPerfMonIntervalTable 1 } Winlink1000OduPerfMonIntervalEntry ::= SEQUENCE { winlink1000OduPerfMonIntervalIdx INTEGER, winlink1000OduPerfMonIntervalUAS Gauge, winlink1000OduPerfMonIntervalES Gauge, winlink1000OduPerfMonIntervalSES Gauge, winlink1000OduPerfMonIntervalBBE Gauge, winlink1000OduPerfMonIntervalIntegrity INTEGER, winlink1000OduPerfMonIntervalCompressed OCTET STRING } winlink1000OduPerfMonIntervalIdx OBJECT-TYPE SYNTAX INTEGER (1..96) ACCESS read-only STATUS mandatory DESCRIPTION "This table is indexed per interval number. Each interval is of 15 minutes and the oldest is 96." ::= { winlink1000OduPerfMonIntervalEntry 1 } winlink1000OduPerfMonIntervalUAS OBJECT-TYPE SYNTAX Gauge (0..900) ACCESS read-only STATUS mandatory DESCRIPTION " The current number of Unavailable Seconds per interval." ::= { winlink1000OduPerfMonIntervalEntry 2 } winlink1000OduPerfMonIntervalES OBJECT-TYPE SYNTAX Gauge (0..900) ACCESS read-only STATUS mandatory DESCRIPTION "Current number of Errored Seconds per interval." ::= { winlink1000OduPerfMonIntervalEntry 3 } winlink1000OduPerfMonIntervalSES OBJECT-TYPE SYNTAX Gauge (0..900) ACCESS read-only STATUS mandatory DESCRIPTION "Current number of Severely Errored Seconds per interval." ::= { winlink1000OduPerfMonIntervalEntry 4 } winlink1000OduPerfMonIntervalBBE OBJECT-TYPE SYNTAX Gauge (0..1800000) ACCESS read-only STATUS mandatory DESCRIPTION "Current number of Background Block Errors per interval." ::= { winlink1000OduPerfMonIntervalEntry 5 } winlink1000OduPerfMonIntervalIntegrity OBJECT-TYPE SYNTAX INTEGER { true(1), false(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the integrity of the entry per interval." ::= { winlink1000OduPerfMonIntervalEntry 6 } winlink1000OduPerfMonIntervalCompressed OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Holds a compressed string of all data per interface. Compressed Air Interface Structure (size in brackets): UAS (4), ES (4), SES (4), BBE (4), Integrity (1), MinRSL (1), MaxRSL (1), RSLThresh1Exceeded (4), RSLThresh2Exceeded (4), MinTSL (1), MaxTSL (1), TSLThresh1Exceed (4), BBERThresh1Exceed (4), RxMBytes (4) TxMBytes (4), EthCapacityThreshUnder (4), HighTrafficThreshExceed (4) Compressed Etherent ODU interface (size in brackets): UAS (4), ES (4), SES (4), BBE (4), Integrity (1), RxMBytes (4), TxMBytes (4), EthCapacityThreshUnder (4), HighTrafficThreshExceed (4), ActiveSeconds (1) " ::= { winlink1000OduPerfMonIntervalEntry 7} -- ########################################################### -- PM Day Table -- ########################################################### winlink1000OduPerfMonDayTable OBJECT-TYPE SYNTAX SEQUENCE OF Winlink1000OduPerfMonDayEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table defines/keeps the counters of the last month (in resolution of days)." ::= { winlink1000OduPerfMon 3 } winlink1000OduPerfMonDayEntry OBJECT-TYPE SYNTAX Winlink1000OduPerfMonDayEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This is an entry in the Days Table." INDEX {ifIndex, winlink1000OduPerfMonDayIdx } ::= { winlink1000OduPerfMonDayTable 1 } Winlink1000OduPerfMonDayEntry ::= SEQUENCE { winlink1000OduPerfMonDayIdx INTEGER, winlink1000OduPerfMonDayUAS Gauge, winlink1000OduPerfMonDayES Gauge, winlink1000OduPerfMonDaySES Gauge, winlink1000OduPerfMonDayBBE Gauge, winlink1000OduPerfMonDayIntegrity INTEGER, winlink1000OduPerfMonDayCompressed OCTET STRING } winlink1000OduPerfMonDayIdx OBJECT-TYPE SYNTAX INTEGER (1..30) ACCESS read-only STATUS mandatory DESCRIPTION "This table is indexed per interval number. Each interval is of 24 hours and the oldest is 30." ::= { winlink1000OduPerfMonDayEntry 1 } winlink1000OduPerfMonDayUAS OBJECT-TYPE SYNTAX Gauge (0..86400) ACCESS read-only STATUS mandatory DESCRIPTION "The current number of Unavailable Seconds per interval of 24 hours." ::= { winlink1000OduPerfMonDayEntry 2 } winlink1000OduPerfMonDayES OBJECT-TYPE SYNTAX Gauge (0..86400) ACCESS read-only STATUS mandatory DESCRIPTION "Current number of Errored Seconds per interval of 24 hours." ::= { winlink1000OduPerfMonDayEntry 3 } winlink1000OduPerfMonDaySES OBJECT-TYPE SYNTAX Gauge (0..86400) ACCESS read-only STATUS mandatory DESCRIPTION "Current number of Severely Errored Seconds per interval of 24 hours." ::= { winlink1000OduPerfMonDayEntry 4 } winlink1000OduPerfMonDayBBE OBJECT-TYPE SYNTAX Gauge (0..172800000) ACCESS read-only STATUS mandatory DESCRIPTION "Current number of Background Block Errors per interval of 24 hours." ::= { winlink1000OduPerfMonDayEntry 5 } winlink1000OduPerfMonDayIntegrity OBJECT-TYPE SYNTAX INTEGER { true(1), false(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the integrity of the entry per interval of 24 hours." ::= { winlink1000OduPerfMonDayEntry 6 } winlink1000OduPerfMonDayCompressed OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Holds a compressed string of all data per interface. Compressed Air Interface Structure (size in brackets): UAS (4), ES (4), SES (4), BBE (4), Integrity (1), MinRSL (1), MaxRSL (1), RSLThresh1Exceeded (4), RSLThresh2Exceeded (4), MinTSL (1), MaxTSL (1), TSLThresh1Exceed (4), BBERThresh1Exceed (4), RxMBytes (4) TxMBytes (4), EthCapacityThreshUnder (4), HighTrafficThreshExceed (4) Compressed Etherent ODU interface (size in brackets): UAS (4), ES (4), SES (4), BBE (4), Integrity (1), RxMBytes (4), TxMBytes (4), EthCapacityThreshUnder (4), HighTrafficThreshExceed (4), ActiveSeconds (1) " ::= { winlink1000OduPerfMonDayEntry 7} -- ########################################################### -- PM Air Current Table -- ########################################################### winlink1000OduPerfMonAirCurrTable OBJECT-TYPE SYNTAX SEQUENCE OF Winlink1000OduPerfMonAirCurrEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table defines/keeps the air counters of the current 15 min interval." ::= { winlink1000OduPerfMon 4 } winlink1000OduPerfMonAirCurrEntry OBJECT-TYPE SYNTAX Winlink1000OduPerfMonAirCurrEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This is an entry in the Current Interval Table." INDEX {ifIndex } ::= { winlink1000OduPerfMonAirCurrTable 1 } Winlink1000OduPerfMonAirCurrEntry ::= SEQUENCE { winlink1000OduPerfMonAirCurrMinRSL INTEGER, winlink1000OduPerfMonAirCurrMaxRSL INTEGER, winlink1000OduPerfMonAirCurrRSLThresh1Exceed Gauge, winlink1000OduPerfMonAirCurrRSLThresh2Exceed Gauge, winlink1000OduPerfMonAirCurrMinTSL INTEGER, winlink1000OduPerfMonAirCurrMaxTSL INTEGER, winlink1000OduPerfMonAirCurrTSLThresh1Exceed Gauge, winlink1000OduPerfMonAirCurrBBERThresh1Exceed Gauge } winlink1000OduPerfMonAirCurrMinRSL OBJECT-TYPE SYNTAX INTEGER (-100..0) ACCESS read-only STATUS mandatory DESCRIPTION "Current Min Received Level Reference starting from the present 15 minutes period." ::= { winlink1000OduPerfMonAirCurrEntry 1 } winlink1000OduPerfMonAirCurrMaxRSL OBJECT-TYPE SYNTAX INTEGER (-100..0) ACCESS read-only STATUS mandatory DESCRIPTION "Current Max Received Level Reference starting from the present 15 minutes period." ::= { winlink1000OduPerfMonAirCurrEntry 2 } winlink1000OduPerfMonAirCurrRSLThresh1Exceed OBJECT-TYPE SYNTAX Gauge (0..900) ACCESS read-only STATUS mandatory DESCRIPTION "Number of seconds Receive Signal Level exceeded the RSL1 threshold in the last 15 minutes." ::= { winlink1000OduPerfMonAirCurrEntry 3 } winlink1000OduPerfMonAirCurrRSLThresh2Exceed OBJECT-TYPE SYNTAX Gauge (0..900) ACCESS read-only STATUS mandatory DESCRIPTION "Number of seconds Receive Signal Level exceeded the RSL2 threshold in the last 15 minutes." ::= { winlink1000OduPerfMonAirCurrEntry 4 } winlink1000OduPerfMonAirCurrMinTSL OBJECT-TYPE SYNTAX INTEGER (-10..25) ACCESS read-only STATUS mandatory DESCRIPTION "Current Min Transmit Signal Level starting from the present 15 minutes period." ::= { winlink1000OduPerfMonAirCurrEntry 5 } winlink1000OduPerfMonAirCurrMaxTSL OBJECT-TYPE SYNTAX INTEGER (-10..25) ACCESS read-only STATUS mandatory DESCRIPTION "Current Max Transmit Signal Level starting from the present 15 minutes period." ::= { winlink1000OduPerfMonAirCurrEntry 6 } winlink1000OduPerfMonAirCurrTSLThresh1Exceed OBJECT-TYPE SYNTAX Gauge (0..900) ACCESS read-only STATUS mandatory DESCRIPTION "Number of seconds Transmit Signal Level exceeded the TSL1 threshold in the last 15 minutes." ::= { winlink1000OduPerfMonAirCurrEntry 7 } winlink1000OduPerfMonAirCurrBBERThresh1Exceed OBJECT-TYPE SYNTAX Gauge (0..900) ACCESS read-only STATUS mandatory DESCRIPTION "Number of seconds Background Block Error Ratio exceeded the BBER1 threshold in the last 15 minutes." ::= { winlink1000OduPerfMonAirCurrEntry 8 } -- ########################################################### -- PM Air Interval Table -- ########################################################### winlink1000OduPerfMonAirIntervalTable OBJECT-TYPE SYNTAX SEQUENCE OF Winlink1000OduPerfMonAirIntervalEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table defines/keeps the air counters of the last day (in resolution of 15 min intervals)." ::= { winlink1000OduPerfMon 5 } winlink1000OduPerfMonAirIntervalEntry OBJECT-TYPE SYNTAX Winlink1000OduPerfMonAirIntervalEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This is an entry in the Interval Table." INDEX {ifIndex, winlink1000OduPerfMonAirIntervalIdx } ::= { winlink1000OduPerfMonAirIntervalTable 1 } Winlink1000OduPerfMonAirIntervalEntry ::= SEQUENCE { winlink1000OduPerfMonAirIntervalIdx INTEGER, winlink1000OduPerfMonAirIntervalMinRSL INTEGER, winlink1000OduPerfMonAirIntervalMaxRSL INTEGER, winlink1000OduPerfMonAirIntervalRSLThresh1Exceed Gauge, winlink1000OduPerfMonAirIntervalRSLThresh2Exceed Gauge, winlink1000OduPerfMonAirIntervalMinTSL INTEGER, winlink1000OduPerfMonAirIntervalMaxTSL INTEGER, winlink1000OduPerfMonAirIntervalTSLThresh1Exceed Gauge, winlink1000OduPerfMonAirIntervalBBERThresh1Exceed Gauge } winlink1000OduPerfMonAirIntervalIdx OBJECT-TYPE SYNTAX INTEGER (1..96) ACCESS read-only STATUS mandatory DESCRIPTION "This table is indexed per interval number. Each interval is of 15 minutes and the oldest is 96." ::= { winlink1000OduPerfMonAirIntervalEntry 1 } winlink1000OduPerfMonAirIntervalMinRSL OBJECT-TYPE SYNTAX INTEGER (-100..0) ACCESS read-only STATUS mandatory DESCRIPTION "Current Min Received Level Reference per interval." ::= { winlink1000OduPerfMonAirIntervalEntry 2 } winlink1000OduPerfMonAirIntervalMaxRSL OBJECT-TYPE SYNTAX INTEGER (-100..0) ACCESS read-only STATUS mandatory DESCRIPTION "Current Max Received Level Reference per interval." ::= { winlink1000OduPerfMonAirIntervalEntry 3 } winlink1000OduPerfMonAirIntervalRSLThresh1Exceed OBJECT-TYPE SYNTAX Gauge (0..900) ACCESS read-only STATUS mandatory DESCRIPTION "Number of seconds Receive Signal Level exceeded the RSL1 threshold per interval." ::= { winlink1000OduPerfMonAirIntervalEntry 4 } winlink1000OduPerfMonAirIntervalRSLThresh2Exceed OBJECT-TYPE SYNTAX Gauge (0..900) ACCESS read-only STATUS mandatory DESCRIPTION "Number of seconds Receive Signal Level exceeded the RSL2 threshold ACCESS read-only per interval." ::= { winlink1000OduPerfMonAirIntervalEntry 5 } winlink1000OduPerfMonAirIntervalMinTSL OBJECT-TYPE SYNTAX INTEGER (-10..25) ACCESS read-only STATUS mandatory DESCRIPTION "Current Min Transmit Signal Level per interval." ::= { winlink1000OduPerfMonAirIntervalEntry 6 } winlink1000OduPerfMonAirIntervalMaxTSL OBJECT-TYPE SYNTAX INTEGER (-10..25) ACCESS read-only STATUS mandatory DESCRIPTION "Current Max Transmit Signal Level per interval." ::= { winlink1000OduPerfMonAirIntervalEntry 7 } winlink1000OduPerfMonAirIntervalTSLThresh1Exceed OBJECT-TYPE SYNTAX Gauge (0..900) ACCESS read-only STATUS mandatory DESCRIPTION "Number of seconds Transmit Signal Level exceeded the TSL1 threshold per interval." ::= { winlink1000OduPerfMonAirIntervalEntry 8 } winlink1000OduPerfMonAirIntervalBBERThresh1Exceed OBJECT-TYPE SYNTAX Gauge (0..900) ACCESS read-only STATUS mandatory DESCRIPTION "Number of seconds Background Block Error Ratio exceeded the BBER1 threshold per interval." ::= { winlink1000OduPerfMonAirIntervalEntry 9 } -- ########################################################### -- PM Air Day Table -- ########################################################### winlink1000OduPerfMonAirDayTable OBJECT-TYPE SYNTAX SEQUENCE OF Winlink1000OduPerfMonAirDayEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table defines/keeps the air counters of the last month (in resolution of days)." ::= { winlink1000OduPerfMon 6 } winlink1000OduPerfMonAirDayEntry OBJECT-TYPE SYNTAX Winlink1000OduPerfMonAirDayEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This is an entry in the Days Table." INDEX {ifIndex, winlink1000OduPerfMonAirDayIdx } ::= { winlink1000OduPerfMonAirDayTable 1 } Winlink1000OduPerfMonAirDayEntry ::= SEQUENCE { winlink1000OduPerfMonAirDayIdx INTEGER, winlink1000OduPerfMonAirDayMinRSL INTEGER, winlink1000OduPerfMonAirDayMaxRSL INTEGER, winlink1000OduPerfMonAirDayRSLThresh1Exceed Gauge, winlink1000OduPerfMonAirDayRSLThresh2Exceed Gauge, winlink1000OduPerfMonAirDayMinTSL INTEGER, winlink1000OduPerfMonAirDayMaxTSL INTEGER, winlink1000OduPerfMonAirDayTSLThresh1Exceed Gauge, winlink1000OduPerfMonAirDayBBERThresh1Exceed Gauge } winlink1000OduPerfMonAirDayIdx OBJECT-TYPE SYNTAX INTEGER (1..96) ACCESS read-only STATUS mandatory DESCRIPTION "This table is indexed per Day number. Each Day is of 15 minutes and the oldest is 96." ::= { winlink1000OduPerfMonAirDayEntry 1 } winlink1000OduPerfMonAirDayMinRSL OBJECT-TYPE SYNTAX INTEGER (-100..0) ACCESS read-only STATUS mandatory DESCRIPTION "Current Min Received Level Reference per Day." ::= { winlink1000OduPerfMonAirDayEntry 2 } winlink1000OduPerfMonAirDayMaxRSL OBJECT-TYPE SYNTAX INTEGER (-100..0) ACCESS read-only STATUS mandatory DESCRIPTION "Current Max Received Level Reference per Day." ::= { winlink1000OduPerfMonAirDayEntry 3 } winlink1000OduPerfMonAirDayRSLThresh1Exceed OBJECT-TYPE SYNTAX Gauge (0..86400) ACCESS read-only STATUS mandatory DESCRIPTION "Number of seconds Receive Signal Level exceeded the RSL1 threshold per Day." ::= { winlink1000OduPerfMonAirDayEntry 4 } winlink1000OduPerfMonAirDayRSLThresh2Exceed OBJECT-TYPE SYNTAX Gauge (0..86400) ACCESS read-only STATUS mandatory DESCRIPTION "Number of seconds Receive Signal Level exceeded the RSL2 threshold per Day." ::= { winlink1000OduPerfMonAirDayEntry 5 } winlink1000OduPerfMonAirDayMinTSL OBJECT-TYPE SYNTAX INTEGER (-10..25) ACCESS read-only STATUS mandatory DESCRIPTION "Current Min Transmit Signal Level per Day." ::= { winlink1000OduPerfMonAirDayEntry 6 } winlink1000OduPerfMonAirDayMaxTSL OBJECT-TYPE SYNTAX INTEGER (-10..25) ACCESS read-only STATUS mandatory DESCRIPTION "Current Max Transmit Signal Level per Day." ::= { winlink1000OduPerfMonAirDayEntry 7 } winlink1000OduPerfMonAirDayTSLThresh1Exceed OBJECT-TYPE SYNTAX Gauge (0..86400) ACCESS read-only STATUS mandatory DESCRIPTION "Number of seconds Transmit Signal Level exceeded the TSL1 threshold per Day." ::= { winlink1000OduPerfMonAirDayEntry 8 } winlink1000OduPerfMonAirDayBBERThresh1Exceed OBJECT-TYPE SYNTAX Gauge (0..86400) ACCESS read-only STATUS mandatory DESCRIPTION "Number of seconds Background Block Error Ratio exceeded the BBER1 threshold per Day." ::= { winlink1000OduPerfMonAirDayEntry 9 } -- ########################################################### -- PM Eth Current Table -- ########################################################### winlink1000OduPerfMonEthCurrTable OBJECT-TYPE SYNTAX SEQUENCE OF Winlink1000OduPerfMonEthCurrEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table defines/keeps the ethernet counters of the current 15 min interval." ::= { winlink1000OduPerfMon 7 } winlink1000OduPerfMonEthCurrEntry OBJECT-TYPE SYNTAX Winlink1000OduPerfMonEthCurrEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This is an entry in the Current Interval Table." INDEX {ifIndex } ::= { winlink1000OduPerfMonEthCurrTable 1 } Winlink1000OduPerfMonEthCurrEntry ::= SEQUENCE { winlink1000OduPerfMonEthCurrRxMBytes Gauge, winlink1000OduPerfMonEthCurrTxMBytes Gauge, winlink1000OduPerfMonEthCurrEthCapacityThreshUnder Gauge, winlink1000OduPerfMonEthCurrHighTrafficThreshExceed Gauge, winlink1000OduPerfMonEthCurrActiveSeconds Gauge } winlink1000OduPerfMonEthCurrRxMBytes OBJECT-TYPE SYNTAX Gauge (0..11250) ACCESS read-only STATUS mandatory DESCRIPTION "Current RX Mega Bytes starting from the present 15 minutes period." ::= { winlink1000OduPerfMonEthCurrEntry 1 } winlink1000OduPerfMonEthCurrTxMBytes OBJECT-TYPE SYNTAX Gauge (0..11250) ACCESS read-only STATUS mandatory DESCRIPTION "Current Transmit Mega Bytes starting from the present 15 minutes period." ::= { winlink1000OduPerfMonEthCurrEntry 2 } winlink1000OduPerfMonEthCurrEthCapacityThreshUnder OBJECT-TYPE SYNTAX Gauge (0..900) ACCESS read-only STATUS mandatory DESCRIPTION "The number of times throughput was below threshold in the present 15 minutes period. Relevant for point to point systems." ::= { winlink1000OduPerfMonEthCurrEntry 3 } winlink1000OduPerfMonEthCurrHighTrafficThreshExceed OBJECT-TYPE SYNTAX Gauge (0..900) ACCESS read-only STATUS mandatory DESCRIPTION "The number of times actual traffic was above threshold in the present 15 minutes period." ::= { winlink1000OduPerfMonEthCurrEntry 4 } winlink1000OduPerfMonEthCurrActiveSeconds OBJECT-TYPE SYNTAX Gauge (0..900) ACCESS read-only STATUS mandatory DESCRIPTION "The number of seconds in which RPL Ethernet swervice was not blocked in the present 15 minutes period." ::= { winlink1000OduPerfMonEthCurrEntry 5 } -- ########################################################### -- PM Eth Interval Table -- ########################################################### winlink1000OduPerfMonEthIntervalTable OBJECT-TYPE SYNTAX SEQUENCE OF Winlink1000OduPerfMonEthIntervalEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table defines/keeps the ethernet counters of the last day (in resolution of 15 min intervals)." ::= { winlink1000OduPerfMon 8 } winlink1000OduPerfMonEthIntervalEntry OBJECT-TYPE SYNTAX Winlink1000OduPerfMonEthIntervalEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This is an entry in the Interval Table." INDEX {ifIndex, winlink1000OduPerfMonEthIntervalIdx } ::= { winlink1000OduPerfMonEthIntervalTable 1 } Winlink1000OduPerfMonEthIntervalEntry ::= SEQUENCE { winlink1000OduPerfMonEthIntervalIdx INTEGER, winlink1000OduPerfMonEthIntervalRxMBytes Gauge, winlink1000OduPerfMonEthIntervalTxMBytes Gauge, winlink1000OduPerfMonEthIntervalEthCapacityThreshUnder Gauge, winlink1000OduPerfMonEthIntervalHighTrafficThreshExceed Gauge, winlink1000OduPerfMonEthIntervalActiveSeconds Gauge } winlink1000OduPerfMonEthIntervalIdx OBJECT-TYPE SYNTAX INTEGER (1..96) ACCESS read-only STATUS mandatory DESCRIPTION "This table is indexed per interval number. Each interval is of 15 minutes and the oldest is 96." ::= { winlink1000OduPerfMonEthIntervalEntry 1 } winlink1000OduPerfMonEthIntervalRxMBytes OBJECT-TYPE SYNTAX Gauge (0..11250) ACCESS read-only STATUS mandatory DESCRIPTION "Current RX Mega Bytes per interval." ::= { winlink1000OduPerfMonEthIntervalEntry 2 } winlink1000OduPerfMonEthIntervalTxMBytes OBJECT-TYPE SYNTAX Gauge (0..11250) ACCESS read-only STATUS mandatory DESCRIPTION "Current Transmit Mega Bytes per interval." ::= { winlink1000OduPerfMonEthIntervalEntry 3 } winlink1000OduPerfMonEthIntervalEthCapacityThreshUnder OBJECT-TYPE SYNTAX Gauge (0..900) ACCESS read-only STATUS mandatory DESCRIPTION "The number of times throughput was below threshold in the each interval. Relevant for point to point systems." ::= { winlink1000OduPerfMonEthIntervalEntry 4 } winlink1000OduPerfMonEthIntervalHighTrafficThreshExceed OBJECT-TYPE SYNTAX Gauge (0..900) ACCESS read-only STATUS mandatory DESCRIPTION "The number of times actual traffic was above threshold in the each interval." ::= { winlink1000OduPerfMonEthIntervalEntry 5 } winlink1000OduPerfMonEthIntervalActiveSeconds OBJECT-TYPE SYNTAX Gauge (0..900) ACCESS read-only STATUS mandatory DESCRIPTION "The number of seconds in which RPL Ethernet service was not blocked in the each interval." ::= { winlink1000OduPerfMonEthIntervalEntry 6 } -- ########################################################### -- PM Eth Day Table -- ########################################################### winlink1000OduPerfMonEthDayTable OBJECT-TYPE SYNTAX SEQUENCE OF Winlink1000OduPerfMonEthDayEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table defines/keeps the ethernet counters of the last month (in resolution of days)." ::= { winlink1000OduPerfMon 9 } winlink1000OduPerfMonEthDayEntry OBJECT-TYPE SYNTAX Winlink1000OduPerfMonEthDayEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This is an entry in the Days Table." INDEX {ifIndex, winlink1000OduPerfMonEthDayIdx } ::= { winlink1000OduPerfMonEthDayTable 1 } Winlink1000OduPerfMonEthDayEntry ::= SEQUENCE { winlink1000OduPerfMonEthDayIdx INTEGER, winlink1000OduPerfMonEthDayRxMBytes Gauge, winlink1000OduPerfMonEthDayTxMBytes Gauge, winlink1000OduPerfMonEthDayEthCapacityThreshUnder Gauge, winlink1000OduPerfMonEthDayHighTrafficThreshExceed Gauge, winlink1000OduPerfMonEthDayActiveSeconds Gauge } winlink1000OduPerfMonEthDayIdx OBJECT-TYPE SYNTAX INTEGER (1..96) ACCESS read-only STATUS mandatory DESCRIPTION "This table is indexed per Day number. Each interval is of 15 minutes and the oldest is 96." ::= { winlink1000OduPerfMonEthDayEntry 1 } winlink1000OduPerfMonEthDayRxMBytes OBJECT-TYPE SYNTAX Gauge (0..1080000) ACCESS read-only STATUS mandatory DESCRIPTION "Current RX Mega Bytes per day." ::= { winlink1000OduPerfMonEthDayEntry 2 } winlink1000OduPerfMonEthDayTxMBytes OBJECT-TYPE SYNTAX Gauge (0..1080000) ACCESS read-only STATUS mandatory DESCRIPTION "Current Transmit Mega Bytes per day." ::= { winlink1000OduPerfMonEthDayEntry 3 } winlink1000OduPerfMonEthDayEthCapacityThreshUnder OBJECT-TYPE SYNTAX Gauge (0..86400) ACCESS read-only STATUS mandatory DESCRIPTION "The number of times throughput was below threshold each day. Relevant for point to point systems." ::= { winlink1000OduPerfMonEthDayEntry 4 } winlink1000OduPerfMonEthDayHighTrafficThreshExceed OBJECT-TYPE SYNTAX Gauge (0..86400) ACCESS read-only STATUS mandatory DESCRIPTION "The number of times actual traffic was above threshold each day." ::= { winlink1000OduPerfMonEthDayEntry 5 } winlink1000OduPerfMonEthDayActiveSeconds OBJECT-TYPE SYNTAX Gauge (0..86400) ACCESS read-only STATUS mandatory DESCRIPTION "The number of seconds in which RPL Ethernet service was not blocked each day." ::= { winlink1000OduPerfMonEthDayEntry 6 } -- ########################################################### -- PM Tdm Current Table -- ########################################################### winlink1000OduPerfMonTdmCurrTable OBJECT-TYPE SYNTAX SEQUENCE OF Winlink1000OduPerfMonTdmCurrEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table defines/keeps the TDM counters of the current 15 min interval." ::= { winlink1000OduPerfMon 10 } winlink1000OduPerfMonTdmCurrEntry OBJECT-TYPE SYNTAX Winlink1000OduPerfMonTdmCurrEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This is an entry in the Current Interval Table." INDEX {ifIndex } ::= { winlink1000OduPerfMonTdmCurrTable 1 } Winlink1000OduPerfMonTdmCurrEntry ::= SEQUENCE { winlink1000OduPerfMonTdmCurrActiveSeconds Gauge } winlink1000OduPerfMonTdmCurrActiveSeconds OBJECT-TYPE SYNTAX Gauge (0..900) ACCESS read-only STATUS mandatory DESCRIPTION "Parameter indicating whether the TDM service was active. Under TDM backup link, the parameter indicates whether the backup link was active." ::= { winlink1000OduPerfMonTdmCurrEntry 1 } -- ########################################################### -- PM Tdm Interval Table -- ########################################################### winlink1000OduPerfMonTdmIntervalTable OBJECT-TYPE SYNTAX SEQUENCE OF Winlink1000OduPerfMonTdmIntervalEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table defines/keeps the TDM counters of the last day (in resolution of 15 min intervals)." ::= { winlink1000OduPerfMon 11 } winlink1000OduPerfMonTdmIntervalEntry OBJECT-TYPE SYNTAX Winlink1000OduPerfMonTdmIntervalEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This is an entry in the Interval Table." INDEX {ifIndex, winlink1000OduPerfMonTdmIntervalIdx } ::= { winlink1000OduPerfMonTdmIntervalTable 1 } Winlink1000OduPerfMonTdmIntervalEntry ::= SEQUENCE { winlink1000OduPerfMonTdmIntervalIdx INTEGER, winlink1000OduPerfMonTdmIntervalActiveSeconds Gauge } winlink1000OduPerfMonTdmIntervalIdx OBJECT-TYPE SYNTAX INTEGER (1..96) ACCESS read-only STATUS mandatory DESCRIPTION "This table is indexed per interval number. Each interval is of 15 minutes and the oldest is 96." ::= { winlink1000OduPerfMonTdmIntervalEntry 1 } winlink1000OduPerfMonTdmIntervalActiveSeconds OBJECT-TYPE SYNTAX Gauge (0..900) ACCESS read-only STATUS mandatory DESCRIPTION "Parameter indicating whether the TDM service was active. Under TDM backup link, the parameter indicates whether the backup link was active." ::= { winlink1000OduPerfMonTdmIntervalEntry 2 } -- ########################################################### -- PM Tdm Day Table -- ########################################################### winlink1000OduPerfMonTdmDayTable OBJECT-TYPE SYNTAX SEQUENCE OF Winlink1000OduPerfMonTdmDayEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table defines/keeps the TDM counters of the last month (in resolution of days)." ::= { winlink1000OduPerfMon 12 } winlink1000OduPerfMonTdmDayEntry OBJECT-TYPE SYNTAX Winlink1000OduPerfMonTdmDayEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This is an entry in the Days Table." INDEX {ifIndex, winlink1000OduPerfMonTdmDayIdx } ::= { winlink1000OduPerfMonTdmDayTable 1 } Winlink1000OduPerfMonTdmDayEntry ::= SEQUENCE { winlink1000OduPerfMonTdmDayIdx INTEGER, winlink1000OduPerfMonTdmDayActiveSeconds Gauge } winlink1000OduPerfMonTdmDayIdx OBJECT-TYPE SYNTAX INTEGER (1..96) ACCESS read-only STATUS mandatory DESCRIPTION "This table is indexed per Day number. Each interval is of 15 minutes and the oldest is 96." ::= { winlink1000OduPerfMonTdmDayEntry 1 } winlink1000OduPerfMonTdmDayActiveSeconds OBJECT-TYPE SYNTAX Gauge (0..86400) ACCESS read-only STATUS mandatory DESCRIPTION "Parameter indicating whether the TDM service was active. Under TDM backup link, the parameter indicates whether the backup link was active." ::= { winlink1000OduPerfMonTdmDayEntry 2 } -- ########################################################### -- PM Configuration thresholds -- ########################################################### winlink1000OduPerfMonTxThresh1 OBJECT-TYPE SYNTAX INTEGER (-10..25) ACCESS read-write STATUS mandatory DESCRIPTION "When the Transmit power exceeds this threshold, a performance monitoring TSL1 counter is incremented." ::= { winlink1000OduPerfMon 20 } winlink1000OduPerfMonRxThresh1 OBJECT-TYPE SYNTAX INTEGER (-100..0) ACCESS read-write STATUS mandatory DESCRIPTION "When the RX power exceeds this threshold, a performance monitoring RSL1 counter is incremented." ::= { winlink1000OduPerfMon 21 } winlink1000OduPerfMonRxThresh2 OBJECT-TYPE SYNTAX INTEGER (-100..0) ACCESS read-write STATUS mandatory DESCRIPTION "When the RX power exceeds this threshold, a performance monitoring RSL2 counter is incremented." ::= { winlink1000OduPerfMon 22 } winlink1000OduPerfMonBBERThresh1 OBJECT-TYPE SYNTAX INTEGER (0..500) ACCESS read-write STATUS mandatory DESCRIPTION "When the BBER exceeds this threshold, a performance monitoring BBER counter is incremented. The units are 1/10 of a percent." ::= { winlink1000OduPerfMon 23 } winlink1000OduPerfMonEthCapacityThreshKbps OBJECT-TYPE SYNTAX INTEGER (0..100000) ACCESS read-write STATUS mandatory DESCRIPTION "When the current throughput is below this threshold, the corresponding counter is incremented" ::= { winlink1000OduPerfMon 24 } winlink1000OduPerfMonHighTrafficThreshKbps OBJECT-TYPE SYNTAX INTEGER (0..100000) ACCESS read-write STATUS mandatory DESCRIPTION "When the current traffic is above this threshold, then corresponding counter is incremented." ::= { winlink1000OduPerfMon 25 } -- ########################################################### -- ODU SNMP Agent -- ########################################################### winlink1000OduAgent OBJECT IDENTIFIER ::= { winlink1000Odu 7 } winlink1000OduAgnGeneral OBJECT IDENTIFIER ::= { winlink1000OduAgent 1 } winlink1000OduAgnGenAddTrapExt OBJECT-TYPE SYNTAX INTEGER { no(1), yes(2) } ACCESS read-write STATUS mandatory DESCRIPTION "If 'yes' is chosen, the ifIndex, Unit, Severity, Time_T and Alarm Id from the winlink1000OduAgnCurrAlarmTable will be bind to the end of each private trap." ::= { winlink1000OduAgnGeneral 1 } winlink1000OduAgnGenSetMode OBJECT-TYPE SYNTAX INTEGER{ enabled(1), disabledSWU(2), disabledSpectrumAnalysis(3), disabledBeforeResetAfterSWU(4), disabledUpdateConfigurationFiles(5), disabledSWK(6) } ACCESS read-write STATUS mandatory DESCRIPTION "This parameter is reserved to the element manager provided with the product." ::= { winlink1000OduAgnGeneral 2 } winlink1000OduAgnGenLocalConnectionMode OBJECT-TYPE SYNTAX INTEGER{ readWrite(1), readOnly(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Local Connection (Broadcast) Configuration Mode. Options are: 1 - SNMP Read-Write, 2 - SNMP Read-Only." ::= { winlink1000OduAgnGeneral 3 } winlink1000OduAgnNTPCfg OBJECT IDENTIFIER ::= { winlink1000OduAgent 2 } winlink1000OduAgnNTPCfgTimeServerIP OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the server from which the current time is loaded." ::= { winlink1000OduAgnNTPCfg 1 } winlink1000OduAgnNTPCfgTimeOffsetFromUTC OBJECT-TYPE SYNTAX INTEGER (-1440..1440) ACCESS read-write STATUS mandatory DESCRIPTION "Offset from Coordinated Universal Time (minutes). Possible values: -1440..1440." ::= { winlink1000OduAgnNTPCfg 2 } winlink1000OduAgnRealTimeAndDate OBJECT-TYPE SYNTAX OCTET STRING(SIZE(8)) ACCESS read-write STATUS mandatory DESCRIPTION "This parameter specifies the real time and date Format 'YYYY-MM-DD,HH:MM:SS' (Hexadecimal). A date-time specification: field octets contents range ----- ------ -------- ----- 1 1-2 year 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 07 c8 05 1a 0d 1e 0f 00 ( 1992 -5 -26,13:30:15 )" ::= { winlink1000OduAgnNTPCfg 3 } winlink1000OduAdmNTPCfgTimeServerIPv6 OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "IPv6 address of the server from which the current time is loaded." ::= { winlink1000OduAgnNTPCfg 4 } winlink1000OduAgnCurrAlarm OBJECT IDENTIFIER ::= { winlink1000OduAgent 3 } winlink1000OduAgnCurrAlarmLastChange OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This counter is initialized to 0 after a device reset and is incremented upon each change in the winlink1000OduAgnCurrAlarmTable (either an addition or removal of an entry)." ::= { winlink1000OduAgnCurrAlarm 1 } -- ########################################################### -- Active Alarm Table -- ########################################################### winlink1000OduAgnCurrAlarmTable OBJECT-TYPE SYNTAX SEQUENCE OF Winlink1000OduAgnCurrAlarmEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table includes the currently active alarms. When a RAISED trap is sent, an alarm entry is added to the table. When a CLEAR trap is sent, the entry is removed." ::= { winlink1000OduAgnCurrAlarm 2 } winlink1000OduAgnCurrAlarmEntry OBJECT-TYPE SYNTAX Winlink1000OduAgnCurrAlarmEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Entry containing the details of a currently RAISED trap." INDEX { winlink1000OduAgnCurrAlarmCounter } ::= { winlink1000OduAgnCurrAlarmTable 1 } Winlink1000OduAgnCurrAlarmEntry ::= SEQUENCE { winlink1000OduAgnCurrAlarmCounter INTEGER, winlink1000OduAgnCurrAlarmSeverity INTEGER, winlink1000OduAgnCurrAlarmId INTEGER, winlink1000OduAgnCurrAlarmIfIndex INTEGER, winlink1000OduAgnCurrAlarmUnit INTEGER, winlink1000OduAgnCurrAlarmTrapID INTEGER, winlink1000OduAgnCurrAlarmTimeT INTEGER, winlink1000OduAgnCurrAlarmText DisplayString } winlink1000OduAgnCurrAlarmCounter OBJECT-TYPE SYNTAX INTEGER (0..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "A running counter of active alarms. The counter is incremented for every new RAISED trap. It is cleared after a device reset." ::= { winlink1000OduAgnCurrAlarmEntry 1 } winlink1000OduAgnCurrAlarmSeverity OBJECT-TYPE SYNTAX INTEGER { event (1), normal (2), warning (4), minor (8), major (16), critical (32) } ACCESS read-only STATUS mandatory DESCRIPTION "Current Alarm severity." ::= { winlink1000OduAgnCurrAlarmEntry 2 } winlink1000OduAgnCurrAlarmId OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Unique Alarm Identifier (combines alarm type and interface). The same AlarmId is used for RAISED and CLEARED alarms." ::= { winlink1000OduAgnCurrAlarmEntry 3 } winlink1000OduAgnCurrAlarmIfIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Interface Index where the alarm occurred. Alarms that are not associated with a specific interface will have the following value: 65535." ::= { winlink1000OduAgnCurrAlarmEntry 4 } winlink1000OduAgnCurrAlarmUnit OBJECT-TYPE SYNTAX INTEGER { idu(1), odu(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Unit associated with the alarm." ::= { winlink1000OduAgnCurrAlarmEntry 5 } winlink1000OduAgnCurrAlarmTrapID OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "ID of the raised trap that was sent when this alarm was raised." ::= { winlink1000OduAgnCurrAlarmEntry 6 } winlink1000OduAgnCurrAlarmTimeT OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Timestamp of this alarm. This number is in seconds from Midnight January 1st, 1970." ::= { winlink1000OduAgnCurrAlarmEntry 7 } winlink1000OduAgnCurrAlarmText OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Alarm display text (same as the text in the sent trap)." ::= { winlink1000OduAgnCurrAlarmEntry 8 } winlink1000OduAgnLastEvents OBJECT IDENTIFIER ::= { winlink1000OduAgent 4 } winlink1000OduAgnLastEventsNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This counter indicates the size of the winlink1000OduAgnLastEventsTable" ::= { winlink1000OduAgnLastEvents 1 } -- ########################################################### -- Last Events Table -- ########################################################### winlink1000OduAgnLastEventsTable OBJECT-TYPE SYNTAX SEQUENCE OF Winlink1000OduAgnLastEventsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table includes the last events. When a trap is sent, an event entry is added to the table." ::= { winlink1000OduAgnLastEvents 2 } winlink1000OduAgnLastEventsEntry OBJECT-TYPE SYNTAX Winlink1000OduAgnLastEventsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Entry containing the details of last traps." INDEX { winlink1000OduAgnLastEventsIndex } ::= { winlink1000OduAgnLastEventsTable 1 } Winlink1000OduAgnLastEventsEntry ::= SEQUENCE { winlink1000OduAgnLastEventsIndex INTEGER, winlink1000OduAgnLastEventsSeverity INTEGER, winlink1000OduAgnLastEventsIfIndex INTEGER, winlink1000OduAgnLastEventsTimeT INTEGER, winlink1000OduAgnLastEventsText DisplayString, winlink1000OduAgnLastEventsUnit INTEGER } winlink1000OduAgnLastEventsIndex OBJECT-TYPE SYNTAX INTEGER (0..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "The index of the table" ::= { winlink1000OduAgnLastEventsEntry 1 } winlink1000OduAgnLastEventsSeverity OBJECT-TYPE SYNTAX INTEGER { event (1), normal (2), warning (4), minor (8), major (16), critical (32) } ACCESS read-only STATUS mandatory DESCRIPTION "Current Trap severity." ::= { winlink1000OduAgnLastEventsEntry 2 } winlink1000OduAgnLastEventsIfIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Interface Index where the event occurred. Traps that are not associated with a specific interface will have the following value: 65535." ::= { winlink1000OduAgnLastEventsEntry 3 } winlink1000OduAgnLastEventsTimeT OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Timestamp of this trap. This number is in seconds from Midnight January 1st, 1970." ::= { winlink1000OduAgnLastEventsEntry 4 } winlink1000OduAgnLastEventsText OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Trap display text (same as the text in the sent trap)." ::= { winlink1000OduAgnLastEventsEntry 5 } winlink1000OduAgnLastEventsUnit OBJECT-TYPE SYNTAX INTEGER { idu (1), odu (2), carrier1 (3), carrier2 (4), undefined (65535) } ACCESS read-only STATUS mandatory DESCRIPTION "Unit associated with the Trap" ::= { winlink1000OduAgnLastEventsEntry 6 } -- ########################################################### -- ODU Agent Users Table -- ########################################################### winlink1000OduAgnUsersTable OBJECT-TYPE SYNTAX SEQUENCE OF Winlink1000OduAgnUsersEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "SNMP users table. Each user is defined by name, password and profile." ::= { winlink1000OduAgent 5 } winlink1000OduAgnUsersEntry OBJECT-TYPE SYNTAX Winlink1000OduAgnUsersEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "SNMP users table entry." INDEX { winlink1000OduAgnUsersIndex } ::= { winlink1000OduAgnUsersTable 1 } Winlink1000OduAgnUsersEntry ::= SEQUENCE { winlink1000OduAgnUsersIndex INTEGER, winlink1000OduAgnUsersUserName DisplayString, winlink1000OduAgnUsersPassword DisplayString, winlink1000OduAgnUsersProfile INTEGER, winlink1000OduAgnUsersLastAccessTime INTEGER } winlink1000OduAgnUsersIndex OBJECT-TYPE SYNTAX INTEGER (0..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "SNMP users table index." ::= { winlink1000OduAgnUsersEntry 1 } winlink1000OduAgnUsersUserName OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "SNMP users user names." ::= { winlink1000OduAgnUsersEntry 2 } winlink1000OduAgnUsersPassword OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "SNMP users passwords." ::= { winlink1000OduAgnUsersEntry 3 } winlink1000OduAgnUsersProfile OBJECT-TYPE SYNTAX INTEGER { disabled(1), observer(2), admin(3), installer(4), operator(5) } ACCESS read-write STATUS mandatory DESCRIPTION "SNMP users profile (1=Disabled, 2=Observer, 3=Admin, 4=Installer, 5=Operator). " ::= { winlink1000OduAgnUsersEntry 4 } winlink1000OduAgnUsersLastAccessTime OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "SNMP users last access time." ::= { winlink1000OduAgnUsersEntry 5 } winlink1000OduAgnSNMPV3AuthenticationMode OBJECT-TYPE SYNTAX INTEGER { md5(1), sha1(2) } ACCESS read-write STATUS mandatory DESCRIPTION "SNMP V3 Authentication mode: 1-MD5(default), 2-SHA1." ::= { winlink1000OduAgent 6 } -- ########################################################### -- IDU -- ########################################################### winlink1000Idu OBJECT IDENTIFIER ::= { winlink1000 2 } -- ########################################################### -- IDU Admin -- ########################################################### winlink1000IduAdmin OBJECT IDENTIFIER ::= { winlink1000Idu 1 } winlink1000IduAdmProductType OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "IDU configuration description." ::= { winlink1000IduAdmin 1 } winlink1000IduAdmHwRev OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "IDU Hardware Revision." ::= { winlink1000IduAdmin 2 } winlink1000IduAdmSwRev OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "IDU Software Revision." ::= { winlink1000IduAdmin 3 } winlink1000OduAdmNumOfExternalAlarmIn OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the number of currently available External Alarm Inputs." ::= { winlink1000IduAdmin 4 } winlink1000OduAdmExternAlarmInTable OBJECT-TYPE SYNTAX SEQUENCE OF Winlink1000OduAdmExternAlarmInEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This is the External Alarm Inputs table." ::= { winlink1000IduAdmin 5 } winlink1000OduAdmExternAlarmInEntry OBJECT-TYPE SYNTAX Winlink1000OduAdmExternAlarmInEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Entry containing the elements of a single External Alarm Input." INDEX { winlink1000OduAdmExternAlarmInIndex} ::= { winlink1000OduAdmExternAlarmInTable 1 } Winlink1000OduAdmExternAlarmInEntry ::= SEQUENCE { winlink1000OduAdmExternAlarmInIndex INTEGER, winlink1000OduAdmExternAlarmInText DisplayString, winlink1000OduAdmExternAlarmInAdminState INTEGER, winlink1000OduAdmExternAlarmInStatus INTEGER } winlink1000OduAdmExternAlarmInIndex OBJECT-TYPE SYNTAX INTEGER(1..2) ACCESS read-only STATUS mandatory DESCRIPTION "This value indicates the index of the External Alarm Input entry." ::= { winlink1000OduAdmExternAlarmInEntry 1 } winlink1000OduAdmExternAlarmInText OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "This field describes the External Alarm Input. It is an optional string of no more than 64 characters, which will be used in the event being sent as a result of a change in the status of the External Alarm Input." DEFVAL {"Alarm Description"} ::= { winlink1000OduAdmExternAlarmInEntry 2 } winlink1000OduAdmExternAlarmInAdminState OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This value indicates if this External Alarm Input is enabled or disabled." ::= { winlink1000OduAdmExternAlarmInEntry 3 } winlink1000OduAdmExternAlarmInStatus OBJECT-TYPE SYNTAX INTEGER { clear(1), alarm(2), unknown(3) } ACCESS read-only STATUS mandatory DESCRIPTION "This value indicates the current status of the External Alarm Input." ::= { winlink1000OduAdmExternAlarmInEntry 4 } winlink1000IduAdmSN OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "IDU Serial Number" ::= { winlink1000IduAdmin 6 } winlink1000IduAdmIduDetectionMode OBJECT-TYPE SYNTAX INTEGER { mandatoryDisabled(1), mandatoryEnabled(2), userDisabled(3), userEnabled(4) } ACCESS read-write STATUS mandatory DESCRIPTION "The parameter defines whether to send Ethernet frames to detect an IDU. The valid writable values are: userDisabled (3), userEnabled (4). A change requires a reset and is effective after reset." ::= { winlink1000IduAdmin 7 } winlink1000IduAdmMountedTrunks OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of mounted trunks in the IDU " ::= { winlink1000IduAdmin 8 } winlink1000IduAdmLicensedTrunks OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of Licensed Trunks in the IDU " ::= { winlink1000IduAdmin 9 } winlink1000IduAdmVlanSupported OBJECT-TYPE SYNTAX INTEGER { notSupported(1), supported(2), supportedLimited(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Identifies if the local IDU supports VLAN tag/untag" ::= { winlink1000IduAdmin 10 } winlink1000IduAdmVlanEgressMode OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "VLAN tag/untag egress values" ::= { winlink1000IduAdmin 11 } winlink1000IduAdmVlanIngressMode OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "VLAN tag/untag ingress values" ::= { winlink1000IduAdmin 12 } winlink1000IduAdmVlanDefaultPortVIDs OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "VLAN tag/untag default VLAN ids for each port - Right most digit is Vlan priority (0-6), other digits compose Vlan Id (1-4094)" ::= { winlink1000IduAdmin 13 } winlink1000IduAdmVlanLan1UntaggedVIDs OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "VLAN untagged VIDs for LAN1 port" ::= { winlink1000IduAdmin 14 } winlink1000IduAdmVlanLan2UntaggedVIDs OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "VLAN untagged VIDs for LAN2 port" ::= { winlink1000IduAdmin 15 } winlink1000IduAdmVlanSfpUntaggedVIDs OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "VLAN untagged VIDs for Sfp port" ::= { winlink1000IduAdmin 16 } winlink1000IduAdmVlanLan1FilteredVIDs OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "VLAN filtered VIDs for LAN1 port" ::= { winlink1000IduAdmin 17 } winlink1000IduAdmVlanLan2FilteredVIDs OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "VLAN filtered VIDs for LAN2 port" ::= { winlink1000IduAdmin 18 } winlink1000IduAdmVlanSfpFilteredVIDs OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "VLAN filtered VIDs for Sfp port" ::= { winlink1000IduAdmin 19 } winlink1000IduAdmPortsConnection OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "IDU ports connection bitmap. bit 0 - LAN1-LAN2 bit 1 - SFP-LAN1 bit 2 - SFP-LAN2 bit values: 0 - ports are disconnected. 1 - ports are connected." ::= { winlink1000IduAdmin 20 } winlink1000IduAdmVlanMode OBJECT-TYPE SYNTAX INTEGER { normal(1), membership(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Local IDU Vlan Mode." ::= { winlink1000IduAdmin 21 } winlink1000IduAdmVlanMembershipVIDs OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "VLAN Membership VLAN IDs list." ::= { winlink1000IduAdmin 22 } winlink1000IduAdmVlanMembershipPortsCode OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "VLAN Membership ports code. Each value represent the relation (bitmap) Between the suitable VID to the IDU ports. bit 0 - LAN1 bit 1 - LAN2 bit 2 - SFP bit value 0 - not member of appropriate VID bit value 1 - member of appropriate VID" ::= { winlink1000IduAdmin 23 } winlink1000IduAdmVlanMembershipUntaggedHandle OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "VLAN Membership Untagged frames handling. The 3 values representing LAN1, LAN2 and SFP accordingly. For each port, the optional values are: 1 - Discard 2 - Tag 3 - Leave Unmodified" ::= { winlink1000IduAdmin 24 } winlink1000IduAdmVlanMembershipTagUntagged OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "VLAN Membership Untagged frames tagging. The 3 values representing LAN1, LAN2 and SFP accordingly. The value on each port entry represent the tagging value which is built of: VLAN ID & VLAN Priority." ::= { winlink1000IduAdmin 25 } -- ########################################################### -- IDU Service -- ########################################################### winlink1000IduService OBJECT IDENTIFIER ::= { winlink1000Idu 2 } winlink1000IduSrvDesiredTrunks OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Required trunks bitmap. Note that the number of possible trunks that can be configured may vary, based on the IDU hardware configuration, the selected air interface rate and the range of the installation. The provided Manager application enables the user to select only available configurations. A change is effective immediately if applied to a master unit and the link is in service mode." ::= { winlink1000IduService 2 } winlink1000IduSrvServices OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "This parameter is reserved to the Manager application provided with the product." ::= { winlink1000IduService 4 } winlink1000IduSrvActiveTrunks OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A bitmap describing the currently open TDM trunks." ::= { winlink1000IduService 6 } winlink1000IduSrvAvailableTrunks OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A bitmap describing the number of TDM trunks that can be opened in the current configuration. The values take into account the IDU hardware configuration, the air rate and the installation range." ::= { winlink1000IduService 8 } -- ########################################################### -- IDU Possible Services Table (old) -- ########################################################### winlink1000IduSrvPossibleServicesTable OBJECT-TYPE SYNTAX SEQUENCE OF Winlink1000IduSrvPossibleServicesEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "IDU Possible Services table." ::= { winlink1000IduService 10 } winlink1000IduSrvPossibleServicesEntry OBJECT-TYPE SYNTAX Winlink1000IduSrvPossibleServicesEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "IDU Services table entry." INDEX { winlink1000IduSrvPossibleServicesIndex } ::= { winlink1000IduSrvPossibleServicesTable 1 } Winlink1000IduSrvPossibleServicesEntry ::= SEQUENCE { winlink1000IduSrvPossibleServicesIndex INTEGER, winlink1000IduSrvPossibleTdmServices INTEGER, winlink1000IduSrvPossibleEthServices INTEGER, winlink1000IduSrvRemainingRate INTEGER, winlink1000IduSrvTrunkCost INTEGER } winlink1000IduSrvPossibleServicesIndex OBJECT-TYPE SYNTAX INTEGER (0..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "Table index, Rate index of the air interface." ::= { winlink1000IduSrvPossibleServicesEntry 1 } winlink1000IduSrvPossibleTdmServices OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS deprecated DESCRIPTION "Deprecated parameter. A bitmap describing the TDM trunks that can be opened in the corresponding Air Rate." ::= { winlink1000IduSrvPossibleServicesEntry 2 } winlink1000IduSrvPossibleEthServices OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS deprecated DESCRIPTION "Deprecated parameter. This parameter describes if the Ethernet Service can be opened in the corresponding Air Rate. The valid values are: disabled (0), enabled (1)." ::= { winlink1000IduSrvPossibleServicesEntry 3 } winlink1000IduSrvRemainingRate OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Current Ethernet bandwidth in bps per air rate." ::= { winlink1000IduSrvPossibleServicesEntry 4 } winlink1000IduSrvTrunkCost OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Cost of the TDM Service in bps." ::= { winlink1000IduSrvPossibleServicesEntry 5 } -- ########################################################### -- IDU Possible Services Table (new) -- ########################################################### winlink1000IduSrvAvailServicesTable OBJECT-TYPE SYNTAX SEQUENCE OF Winlink1000IduSrvAvailServicesEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "ODU Possible TDM Services table." ::= { winlink1000IduService 11 } winlink1000IduSrvAvailServicesEntry OBJECT-TYPE SYNTAX Winlink1000IduSrvAvailServicesEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "ODU TDM Services table entry." INDEX { winlink1000IduSrvAvailServicesIndex } ::= { winlink1000IduSrvAvailServicesTable 1 } Winlink1000IduSrvAvailServicesEntry ::= SEQUENCE { winlink1000IduSrvAvailServicesIndex INTEGER, winlink1000IduSrvAvailServicesState INTEGER, winlink1000IduSrvAvailServicesMinRateIdx INTEGER, winlink1000IduSrvAvailServicesMaxRateIdx INTEGER, winlink1000IduSrvAvailServicesReason INTEGER } winlink1000IduSrvAvailServicesIndex OBJECT-TYPE SYNTAX INTEGER (0..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "Table index. The index is the bit mask of the TDM service." ::= { winlink1000IduSrvAvailServicesEntry 1 } winlink1000IduSrvAvailServicesState OBJECT-TYPE SYNTAX INTEGER { unavailable(1), available(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Represents the TDM service availability." ::= { winlink1000IduSrvAvailServicesEntry 2 } winlink1000IduSrvAvailServicesMinRateIdx OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Minimum rate index of the air interface which make the service possible." ::= { winlink1000IduSrvAvailServicesEntry 3 } winlink1000IduSrvAvailServicesMaxRateIdx OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Maximum rate index of the air interface which make the service possible." ::= { winlink1000IduSrvAvailServicesEntry 4 } winlink1000IduSrvAvailServicesReason OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), insufficientThroughput(2), notSupportedIDUHw(3), inconsistentLinkParams(4), improperExtPulseType(5), incompatibleSWVersion(6), asymmetricTDD(7) } ACCESS read-only STATUS mandatory DESCRIPTION "Information about the TDM Service availability. - Not Applicable if the service is available. The reasons for TDM Service unavailability: - The available throughput isn't sufficient for Service demands; - The IDU HW doesn't support the service; - A Link Password mismatch was detected; - The external pulse type detected is improper for TDM services; - A Software versions mismatch was detected. - A-Symetric TDD Mode Is Obligated." ::= { winlink1000IduSrvAvailServicesEntry 5 } winlink1000IduSrvEthActive OBJECT-TYPE SYNTAX INTEGER { inactive(1), active(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Represents the Ethernet service activation state." ::= { winlink1000IduService 12 } winlink1000IduSrvEthAvailable OBJECT-TYPE SYNTAX INTEGER { unavailable(1), available(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Represents the Ethernet service availability state." ::= { winlink1000IduService 13 } winlink1000IduSrvEthThroughput OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "Current available Ethernet service throughput in bps." ::= { winlink1000IduService 14 } winlink1000IduSrvEthMaxInfoRate OBJECT-TYPE SYNTAX INTEGER (0..122880) ACCESS read-write STATUS mandatory DESCRIPTION "Holds the maximum bandwidth (kbps) to be allocated for Ethernet service. Value of zero means that Ethernet service works as best effort. The maximum value is product specific. Refer to the user manual." ::= { winlink1000IduService 15 } winlink1000IduSrvAvailableTrunksT1 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A bitmap describing the TDM trunks that can be opened under T1 configuration. The values take into account the IDU hardware configuration, the air rate and the installation range." ::= { winlink1000IduService 16 } -- ########################################################### -- IDU Ethernet -- ########################################################### winlink1000IduEthernet OBJECT IDENTIFIER ::= { winlink1000Idu 3 } -- ########################################################### -- IDU Ethernet Interface Table -- ########################################################### winlink1000IduEthernetIfTable OBJECT-TYPE SYNTAX SEQUENCE OF Winlink1000IduEthernetIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "IDU Ethernet Interface table." ::= { winlink1000IduEthernet 1 } winlink1000IduEthernetIfEntry OBJECT-TYPE SYNTAX Winlink1000IduEthernetIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "IDU Ethernet Interface table entry." INDEX { winlink1000IduEthernetIfIndex } ::= { winlink1000IduEthernetIfTable 1 } Winlink1000IduEthernetIfEntry ::= SEQUENCE { winlink1000IduEthernetIfIndex INTEGER, winlink1000IduEthernetIfAddress DisplayString } winlink1000IduEthernetIfIndex OBJECT-TYPE SYNTAX INTEGER (0..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "If Index corresponding to this Interface." ::= { winlink1000IduEthernetIfEntry 1 } winlink1000IduEthernetIfAddress OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "IDU MAC address." ::= { winlink1000IduEthernetIfEntry 5 } winlink1000IduEthernetNumOfLanPorts OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of LAN interfaces in the IDU." ::= { winlink1000IduEthernet 3 } winlink1000IduEthernetNumOfSfpPorts OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of SFP interfaces in the IDU." ::= { winlink1000IduEthernet 4 } winlink1000IduEthernetSfpProperties OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "SFP venfor properties : Vendor Name, PN and Revision." ::= { winlink1000IduEthernet 5 } winlink1000IduEthernetGbeSupported OBJECT-TYPE SYNTAX INTEGER {notSupported(1), supported(2)} ACCESS read-only STATUS mandatory DESCRIPTION "Supported Giga bit Ethernet in IDU." ::= { winlink1000IduEthernet 6 } winlink1000IduEthernetOduInErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of inbound packets that contained errors preventing them from being deliverable to a higher-layer protocol." ::= { winlink1000IduEthernet 7 } -- ########################################################### -- IDU Bridge -- ########################################################### winlink1000IduBridge OBJECT IDENTIFIER ::= { winlink1000Idu 4 } -- ########################################################### -- IDU Bridge Tp -- ########################################################### winlink1000IduBridgeTp OBJECT IDENTIFIER ::= { winlink1000IduBridge 4 } winlink1000IduBridgeTpAging OBJECT-TYPE SYNTAX INTEGER (1..1048575) ACCESS read-write STATUS mandatory DESCRIPTION "Timeout in seconds for aging. Note that for this parameter to be effective, the ODU must be configured to HUB mode. A change is effective immediately." ::= { winlink1000IduBridgeTp 2 } -- ########################################################### -- IDU TDM -- ########################################################### winlink1000IduTdm OBJECT IDENTIFIER ::= { winlink1000Idu 6 } winlink1000IduTdmTxClock OBJECT IDENTIFIER ::= { winlink1000IduTdm 1 } winlink1000IduTdmTxClockAvailStates OBJECT-TYPE SYNTAX INTEGER (0..62) ACCESS read-only STATUS mandatory DESCRIPTION "Available states of the TDM Transmit Clock Control, each input status is represented by a bit. When the state is available, the bit value is 1. When the state is unavailable, the bit value is 0. The available states are: bit 2 = Transparent bit 3 = Local Loop Timed bit 4 = Remote Loop Timed bit 5 = Local Internal bit 6 = Remote Internal" ::= { winlink1000IduTdmTxClock 1 } winlink1000IduTdmTxClockDesiredState OBJECT-TYPE SYNTAX INTEGER { transparent(2), localLT(4), remoteLT(8), localInternal(16), remoteInternal(32), multipleClock(64) } ACCESS read-write STATUS mandatory DESCRIPTION "Required state of the TDM Transmit Clock Control. A change is effective after re-activation of the TDM service." ::= { winlink1000IduTdmTxClock 2 } winlink1000IduTdmTxClockActualState OBJECT-TYPE SYNTAX INTEGER { notAvailable(1), transparent(2), localLT(4), remoteLT(8), localInternal(16), remoteInternal(32), multipleClock(64) } ACCESS read-only STATUS mandatory DESCRIPTION "Actual state of the TDM Transmit Clock Control." ::= { winlink1000IduTdmTxClock 3 } winlink1000IduTdmMasterClock OBJECT IDENTIFIER ::= { winlink1000IduTdm 2 } winlink1000IduTdmMasterClockAvailOptions OBJECT-TYPE SYNTAX INTEGER (0..62) ACCESS read-only STATUS mandatory DESCRIPTION "Available options of the TDM Master Clock Control, each input status is represented by a bit. When the option is available, the bit value is 1. When the option is unavailable, the bit value is 0. The available options are: bit 2 = Automatic bit 3 = Trunk #1 bit 4 = Trunk #2 bit 5 = Trunk #3 bit 6 = Trunk #4 When no options are available the returned value is: 1" ::= { winlink1000IduTdmMasterClock 1 } winlink1000IduTdmMasterClockDesired OBJECT-TYPE SYNTAX INTEGER { automatic(2), trunk1(4), trunk2(8), trunk3(16), trunk4(32), multipleClocks(64) } ACCESS read-write STATUS mandatory DESCRIPTION "Required TDM Master Clock. A change is effective after re-activation of the TDM service." ::= { winlink1000IduTdmMasterClock 2 } winlink1000IduTdmMasterClockActual OBJECT-TYPE SYNTAX INTEGER { notAvailable(1), trunk1(4), trunk2(8), trunk3(16), trunk4(32), multipleClocks(64) } ACCESS read-only STATUS mandatory DESCRIPTION "Actual Trunk used for TDM Master Clock." ::= { winlink1000IduTdmMasterClock 3 } -- ########################################################### -- IDU TDM Links Configuration Table -- ########################################################### winlink1000IduTdmConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF Winlink1000IduTdmConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "IDU TDM Links Configuration table." ::= { winlink1000IduTdm 6 } winlink1000IduTdmConfigEntry OBJECT-TYPE SYNTAX Winlink1000IduTdmConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "IDU TDM Links Configuration table entry." INDEX { winlink1000IduTdmConfigIndex } ::= { winlink1000IduTdmConfigTable 1 } Winlink1000IduTdmConfigEntry ::= SEQUENCE { winlink1000IduTdmConfigIndex INTEGER, winlink1000IduTdmIfIndex INTEGER, winlink1000IduTdmLineCoding INTEGER, winlink1000IduTdmLoopbackConfig INTEGER, winlink1000IduTdmLineStatus INTEGER } winlink1000IduTdmConfigIndex OBJECT-TYPE SYNTAX INTEGER (0..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "Table index." ::= { winlink1000IduTdmConfigEntry 1 } winlink1000IduTdmIfIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Link index in the interface table." ::= { winlink1000IduTdmConfigEntry 2 } winlink1000IduTdmLineCoding OBJECT-TYPE SYNTAX INTEGER { b8zs (2), ami (5) } ACCESS read-write STATUS mandatory DESCRIPTION "This parameter applies to T1 trunks only. The parameter controls the line coding. Setting the value to each of the indices applies to all. A change is effective after the next open of the TDM service." ::= { winlink1000IduTdmConfigEntry 6 } winlink1000IduTdmLoopbackConfig OBJECT-TYPE SYNTAX INTEGER { normal (1), lineLoopBack (3), revereseLineLoopBack (4) } ACCESS read-write STATUS mandatory DESCRIPTION "Loop back configuration table. Each of the trunks can be set Normal, Line loop back or Reverse line loop back. A change is effective immediately." ::= { winlink1000IduTdmConfigEntry 9 } winlink1000IduTdmLineStatus OBJECT-TYPE SYNTAX INTEGER { normal (1), ais (8), los (64), loopback (128) } ACCESS read-only STATUS mandatory DESCRIPTION "Line status." ::= { winlink1000IduTdmConfigEntry 10 } -- ########################################################### -- IDU TDM Links Statistics Table -- ########################################################### winlink1000IduTdmCurrentTable OBJECT-TYPE SYNTAX SEQUENCE OF Winlink1000IduTdmCurrentEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "IDU TDM Links Statistics table." ::= { winlink1000IduTdm 7 } winlink1000IduTdmCurrentEntry OBJECT-TYPE SYNTAX Winlink1000IduTdmCurrentEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "IDU TDM Links Statistics table entry." INDEX { winlink1000IduTdmCurrentIndex } ::= { winlink1000IduTdmCurrentTable 1 } Winlink1000IduTdmCurrentEntry ::= SEQUENCE { winlink1000IduTdmCurrentIndex INTEGER, winlink1000IduTdmCurrentBlocks Counter, winlink1000IduTdmCurrentDrops Counter, winlink1000IduTdmCurrentTxClock INTEGER, winlink1000IduTdmCurrentBlocksHigh Counter } winlink1000IduTdmCurrentIndex OBJECT-TYPE SYNTAX INTEGER (0..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "Table index (Same as winlink1000IduTdmLineIndex)." ::= { winlink1000IduTdmCurrentEntry 1 } winlink1000IduTdmCurrentBlocks OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of correct blocks transmitted to the line." ::= { winlink1000IduTdmCurrentEntry 101 } winlink1000IduTdmCurrentDrops OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of error blocks transmitted to the line." ::= { winlink1000IduTdmCurrentEntry 102 } winlink1000IduTdmCurrentTxClock OBJECT-TYPE SYNTAX INTEGER { transparent(2), localLT(4), remoteLT(8), localInternal(16), remoteInternal(32) } ACCESS read-write STATUS mandatory DESCRIPTION "TDM Transmit Clock. A change is effective after re-activation of the TDM service." ::= { winlink1000IduTdmCurrentEntry 103 } winlink1000IduTdmCurrentBlocksHigh OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "High part of the 64 bits counter Current Blocks" ::= { winlink1000IduTdmCurrentEntry 104 } winlink1000IduTdmRemoteQual OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Estimated average interval between error second events. The valid values are 1-2^31 where a value of -1 is used to indicate an undefined state." ::= { winlink1000IduTdm 8 } winlink1000IduTdmRemoteQualEval OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Estimated average interval between error second events during evaluation process. The valid values are 1-2^31 where a value of -1 is used to indicate an undefined state." ::= { winlink1000IduTdm 9 } winlink1000IduTdmSrvEval OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Evaluated TDM service bit mask. Setting this parameter to value that is bigger than the activated TDM service bit mask will execute the evaluation process for 30 seconds. Setting this parameter to 0 will stop the evaluation process immediately." ::= { winlink1000IduTdm 10 } winlink1000IduTdmBackupAvailableLinks OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of TDM backup trunks." ::= { winlink1000IduTdm 11 } -- ########################################################### -- IDU TDM Backup Links Table -- ########################################################### winlink1000IduTdmBackupTable OBJECT-TYPE SYNTAX SEQUENCE OF Winlink1000IduTdmBackupEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "IDU TDM Links Statistics table." ::= { winlink1000IduTdm 12 } winlink1000IduTdmBackupEntry OBJECT-TYPE SYNTAX Winlink1000IduTdmBackupEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "IDU TDM Links Statistics table entry." INDEX { winlink1000IduTdmBackupIndex } ::= { winlink1000IduTdmBackupTable 1 } Winlink1000IduTdmBackupEntry ::= SEQUENCE { winlink1000IduTdmBackupIndex INTEGER, winlink1000IduTdmBackupMode INTEGER, winlink1000IduTdmBackupCurrentActiveLink INTEGER } winlink1000IduTdmBackupIndex OBJECT-TYPE SYNTAX INTEGER (1..16) ACCESS read-only STATUS mandatory DESCRIPTION "Table index." ::= { winlink1000IduTdmBackupEntry 1 } winlink1000IduTdmBackupMode OBJECT-TYPE SYNTAX INTEGER { enableUseAirLinkAsBackupLink(1), enableUseExternalLinkAsBackupLink(2), disableUseExternalLinkAsMainLink(3), disableUseAirLinkAsMainLink(4) } ACCESS read-write STATUS mandatory DESCRIPTION "TDM backup mode: Enable or Disable, where the main link is the air link or the external link. Changes will be effective immediatly." ::= { winlink1000IduTdmBackupEntry 2 } winlink1000IduTdmBackupCurrentActiveLink OBJECT-TYPE SYNTAX INTEGER { notAvailable(1), airLinkIsActive(2), externalLinkIsActive(3), noLinkIsActive(4) } ACCESS read-only STATUS mandatory DESCRIPTION "TDM backup current active link: N/A, air link is active or external link is active." ::= { winlink1000IduTdmBackupEntry 3 } winlink1000IduTdmJitterBufferSize OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "TDM Jitter Buffer Size. The value must be between the minimum and the maximum TDM Jitter Buffer Size. The units are 0.1 x millisecond." ::= { winlink1000IduTdm 13 } winlink1000IduTdmJitterBufferDefaultSize OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "TDM Jitter Buffer Default Size. The units are 0.1 x millisecond." ::= { winlink1000IduTdm 14 } winlink1000IduTdmJitterBufferMinSize OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "TDM Jitter Buffer Minimum Size. The units are 0.1 x millisecond." ::= { winlink1000IduTdm 15 } winlink1000IduTdmJitterBufferMaxSize OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "TDM Jitter Buffer Maximum Size. The units are 0.1 x millisecond." ::= { winlink1000IduTdm 16 } winlink1000IduTdmJitterBufferSizeEval OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "TDM Jitter Buffer Size for evaluation. The value must be between the minimum and the maximum TDM Jitter Buffer Size. The units are 0.1 x millisecond." ::= { winlink1000IduTdm 17 } winlink1000IduTdmType OBJECT-TYPE SYNTAX INTEGER{ unDefined(1), e1(2), t1(3) } ACCESS read-write STATUS mandatory DESCRIPTION "TDM Type (The value undefined is read-only)." ::= { winlink1000IduTdm 18 } winlink1000IduTdmTypeEval OBJECT-TYPE SYNTAX INTEGER{ unDefined(1), e1(2), t1(3) } ACCESS read-write STATUS mandatory DESCRIPTION "TDM Type for evaluation." ::= { winlink1000IduTdm 19 } winlink1000IduTdmLineStatusStr OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Line status." ::= { winlink1000IduTdm 20 } winlink1000IduTdmHotStandbySupport OBJECT-TYPE SYNTAX INTEGER{ supported(1), notSupported(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates if Hot Standby is supported." ::= { winlink1000IduTdm 21 } winlink1000IduTdmDesiredHotStandbyMode OBJECT-TYPE SYNTAX INTEGER{ primary(1), secondary(2), disabled(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Desired Hot Standby Mode." ::= { winlink1000IduTdm 22 } winlink1000IduTdmHotStandbyOperationStatus OBJECT-TYPE SYNTAX INTEGER{ active(1), notActive(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The Link Actual Status." ::= { winlink1000IduTdm 23 } winlink1000IduTdmBackupLinkConfiguration OBJECT-TYPE SYNTAX INTEGER{ independent(1), repeaterEnd(2), lineEnd(3) } ACCESS read-write STATUS mandatory DESCRIPTION "The current configuration of the backup link." ::= { winlink1000IduTdm 24 } winlink1000IduTdmLineInterfaceConfiguration OBJECT-TYPE SYNTAX INTEGER{ balanced(1), unBalanced(2) } ACCESS read-write STATUS mandatory DESCRIPTION "TDM Line interface configuration." ::= { winlink1000IduTdm 25 } winlink1000IduTdmLineImpedanceConfiguration OBJECT-TYPE SYNTAX INTEGER{ standardT1(1), nonStandardT1(2) } ACCESS read-write STATUS mandatory DESCRIPTION "TDM line impedance configuration (standardT1 - 100Ohm, nonStandardT1 - 110Ohm) Applicable only for T1 TDM type." ::= { winlink1000IduTdm 26 } -- ########################################################### -- HBS -- ########################################################### winlink1000Hbs OBJECT IDENTIFIER ::= { winlink1000 3 } -- ########################################################### -- HBS Air -- ########################################################### winlink1000HbsAir OBJECT IDENTIFIER ::= { winlink1000Hbs 1 } winlink1000HbsAirState OBJECT-TYPE SYNTAX INTEGER { init (1), bitFailed (2), inactive (3), spectrumMeasurement (4), scanning (5), cac (6), transceiving (7), standBy (8), rawAlignment (9), deviceNotReachable (10), tvwsDbDisabled (11), unauthorized (12), fail (13) } ACCESS read-only STATUS mandatory DESCRIPTION "Holds the state of the HBS." ::= { winlink1000HbsAir 1 } winlink1000HbsAirOpMode OBJECT-TYPE SYNTAX INTEGER { inactive (1), active (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Holds the operation mode of the HBS." ::= { winlink1000HbsAir 2 } winlink1000HbsAirAvailTimeSlots OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This parameter holds the number of available time slots (not in use) in the air interface." ::= { winlink1000HbsAir 3 } winlink1000HbsAirSectorCbwSupportedStr OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Represents the channel bandwidth which is supported by the HBS and all connected HSUs." ::= { winlink1000HbsAir 4 } winlink1000HbsAirCompressedMon OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Holds HBS monitor data in compressed format: HBS Traffic Monitor In Bytes(4) Out Bytes(4) In Frames(4) Out Frames(4) HBS State (1) HBS Freq (4) Number of Links (2) EC Change Counter (4) Current Ratio (2) Total Air Frames (4) HBS Rx Rate in Kbps (4) HBS Tx Rate in Kbps (4) HBS Rx Rate in Fps (4) HBS Tx Rate in Fps (4) HBS Set Mode (1) HBS LAN 1 Rx Rate in Kbps (4) HBS LAN 1 Tx Rate in Kbps (4) HBS LAN 1 Rx Rate in Fps (4) HBS LAN 1 Tx Rate in Fps (4) HBS LAN 2 Rx Rate in Kbps (4) HBS LAN 2 Tx Rate in Kbps (4) HBS LAN 2 Rx Rate in Fps (4) HBS LAN 2 Tx Rate in Fps (4) SyncE Performance (1) Max Available BE HSUs (1)." ::= { winlink1000HbsAir 5 } winlink1000HbsAirConf OBJECT IDENTIFIER ::= { winlink1000HbsAir 6 } winlink1000HbsAirConfChanges OBJECT-TYPE SYNTAX OCTET STRING(SIZE(16)) ACCESS read-only STATUS mandatory DESCRIPTION "16 characters that represent 16 HSUs. Each time a configuration is been changed, increment the relevant character." ::= { winlink1000HbsAirConf 1 } -- ########################################################### -- HSUs Configuration Table -- ########################################################### winlink1000HbsAirConfTable OBJECT-TYPE SYNTAX SEQUENCE OF Winlink1000HbsAirConfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Holds the table for all registered HSUs in the sector (31 entries)." ::= { winlink1000HbsAirConf 2 } winlink1000HbsAirConfEntry OBJECT-TYPE SYNTAX Winlink1000HbsAirConfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "HSUs configuration table entry." INDEX { winlink1000HbsAirConfIndex } ::= { winlink1000HbsAirConfTable 1 } Winlink1000HbsAirConfEntry ::= SEQUENCE { winlink1000HbsAirConfIndex INTEGER, winlink1000HbsAirConfUpMir INTEGER, winlink1000HbsAirConfDownMir INTEGER, winlink1000HbsAirConfHsuName DisplayString, winlink1000HbsAirConfHsuLocation DisplayString, winlink1000HbsAirConfDualAntTxMode INTEGER, winlink1000HbsAirConfNumOfTs INTEGER, winlink1000HbsAirConfGeoLocation DisplayString, winlink1000HbsAirConfHsuType INTEGER, winlink1000HbsAirConfHsuLevel INTEGER, winlink1000HbsAirConfDesiredRateIndex INTEGER, winlink1000HbsAirConfMacAddress DisplayString, winlink1000HbsAirConfNumOfTsUp INTEGER, winlink1000HbsAirConfLanPortsConnection INTEGER, winlink1000HbsAirConfServiceCategory INTEGER, winlink1000HbsAirConfAutoRealignmentConfiguration DisplayString, winlink1000HbsAirConfBeaconRssSyncLossThreshold INTEGER, winlink1000HbsAirConfNumOfResourcesDL INTEGER, winlink1000HbsAirConfNumOfResourcesUL INTEGER, winlink1000HbsAirConfResourceType INTEGER, winlink1000HbsAirConfDelaySensitivity INTEGER, winlink1000HbsAirConfLQDActivation INTEGER, winlink1000HbsAirConfLQDBaselineDl INTEGER, winlink1000HbsAirConfLQDBaselineUl INTEGER, winlink1000HbsAirConfLQDCurrentQualityDl INTEGER, winlink1000HbsAirConfLQDCurrentQualityUl INTEGER, winlink1000HbsAirConfLQDAlarmThresholdDl INTEGER, winlink1000HbsAirConfLQDAlarmThresholdUl INTEGER, winlink1000HbsAirConfLQDAlarmClearThresholdDl INTEGER, winlink1000HbsAirConfLQDAlarmClearThresholdUl INTEGER, winlink1000HbsAirConfIpAddress DisplayString, winlink1000HbsAirConfCarrierId INTEGER } winlink1000HbsAirConfIndex OBJECT-TYPE SYNTAX INTEGER (0..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "HSUs configuration table index." ::= { winlink1000HbsAirConfEntry 1 } winlink1000HbsAirConfUpMir OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Uplink MIR towards specific HSU in units of kbps." ::= { winlink1000HbsAirConfEntry 2 } winlink1000HbsAirConfDownMir OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Downlink MIR towards specific HSU in units of kbps." ::= { winlink1000HbsAirConfEntry 3 } winlink1000HbsAirConfHsuName OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "HSU name." ::= { winlink1000HbsAirConfEntry 4 } winlink1000HbsAirConfHsuLocation OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "HSU location." ::= { winlink1000HbsAirConfEntry 5 } winlink1000HbsAirConfDualAntTxMode OBJECT-TYPE SYNTAX INTEGER { mimo (1), diversity (2), autoSelection (3) } ACCESS read-write STATUS mandatory DESCRIPTION "Transmission type when using Dual Antenna on both link's sides. spatial Multiplexing, Diversity (using a single spatial stream), and Auto Selection (OMS control)." ::= { winlink1000HbsAirConfEntry 6 } winlink1000HbsAirConfNumOfTs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Number of time slot which are allocated to specific HSU." ::= { winlink1000HbsAirConfEntry 7 } winlink1000HbsAirConfGeoLocation OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Geographic device location in format: latitude,longitude." ::= { winlink1000HbsAirConfEntry 8 } winlink1000HbsAirConfHsuType OBJECT-TYPE SYNTAX INTEGER { fixed (1), stationary (2), mobile (3), transport (4), mobileCoChannel (5), residential (6), nFixed (7), nResidential (8) } ACCESS read-only STATUS mandatory DESCRIPTION "HSU type (1 = Fixed, 2 = Stationary, 3 = Mobile, 4 = Transport, 5 = Mobile_co_channel, 6 = Residential, 7 = N_Fixed, 8 = N_Residential)" ::= { winlink1000HbsAirConfEntry 9 } winlink1000HbsAirConfHsuLevel OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "HSU level (1 .. 4)" ::= { winlink1000HbsAirConfEntry 10 } winlink1000HbsAirConfDesiredRateIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The rate index of both sides of the link to this HSU." ::= { winlink1000HbsAirConfEntry 11 } winlink1000HbsAirConfMacAddress OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "HSU MAC Address." ::= { winlink1000HbsAirConfEntry 12 } winlink1000HbsAirConfNumOfTsUp OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Number of UL time slot which are allocated to specific HSU." ::= { winlink1000HbsAirConfEntry 13 } winlink1000HbsAirConfLanPortsConnection OBJECT-TYPE SYNTAX INTEGER { enabled (1), disabled (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Indicates if the connection between LAN 1 and LAN 2 is enabled. 1- Enabled , 2- Disabled." ::= { winlink1000HbsAirConfEntry 14 } winlink1000HbsAirConfServiceCategory OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicates Service Category received from Radius server,values can be from 1 to 8 , 0 - undefined" ::= { winlink1000HbsAirConfEntry 15 } winlink1000HbsAirConfAutoRealignmentConfiguration OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Configuration Parameters For Auto Realignment." ::= { winlink1000HbsAirConfEntry 16 } winlink1000HbsAirConfBeaconRssSyncLossThreshold OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "RSS Threshold For Syncloss In Mobile Units" ::= { winlink1000HbsAirConfEntry 17 } winlink1000HbsAirConfNumOfResourcesDL OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Number of DownLink Resources which are allocated to specific HSU." ::= { winlink1000HbsAirConfEntry 18 } winlink1000HbsAirConfNumOfResourcesUL OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Number of UpLink Resources which are allocated to specific HSU." ::= { winlink1000HbsAirConfEntry 19 } winlink1000HbsAirConfResourceType OBJECT-TYPE SYNTAX INTEGER { assuredAllocation (1), bestEffort (2), undefined (3) } ACCESS read-write STATUS mandatory DESCRIPTION "Resources Allocation Type (AA or BE) to specific HSU." ::= { winlink1000HbsAirConfEntry 20 } winlink1000HbsAirConfDelaySensitivity OBJECT-TYPE SYNTAX INTEGER { sensitive (1), insensitive (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Delay Sensitivity to specific HSU." ::= { winlink1000HbsAirConfEntry 21 } winlink1000HbsAirConfLQDActivation OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabled (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Link quality detection activation status" ::= { winlink1000HbsAirConfEntry 22 } winlink1000HbsAirConfLQDBaselineDl OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Link quality detection downlink baseline" ::= { winlink1000HbsAirConfEntry 23 } winlink1000HbsAirConfLQDBaselineUl OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Link quality detection uplink baseline" ::= { winlink1000HbsAirConfEntry 24 } winlink1000HbsAirConfLQDCurrentQualityDl OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Link quality detection current downlink quality in kbps." ::= { winlink1000HbsAirConfEntry 25 } winlink1000HbsAirConfLQDCurrentQualityUl OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Link quality detection current uplink quality in kbps." ::= { winlink1000HbsAirConfEntry 26 } winlink1000HbsAirConfLQDAlarmThresholdDl OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Link quality detection downlink alarm threshold in kbps." ::= { winlink1000HbsAirConfEntry 27 } winlink1000HbsAirConfLQDAlarmThresholdUl OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Link quality detection uplink alarm threshold in kbps." ::= { winlink1000HbsAirConfEntry 28 } winlink1000HbsAirConfLQDAlarmClearThresholdDl OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Link quality detection downlink alarm clear threshold in kbps." ::= { winlink1000HbsAirConfEntry 29 } winlink1000HbsAirConfLQDAlarmClearThresholdUl OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Link quality detection uplink alarm clear threshold in kbps." ::= { winlink1000HbsAirConfEntry 30 } winlink1000HbsAirConfIpAddress OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "HSU IP Address. Writable access only for manager" ::= { winlink1000HbsAirConfEntry 31 } winlink1000HbsAirConfCarrierId OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Carrier Id" ::= { winlink1000HbsAirConfEntry 32 } -- ########################################################### -- Beacon Rss SyncLoss Threshold Table -- ########################################################### winlink1000HbsAirConfBeaconRssSyncLossInterval OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Interval over which the RSS value is below the threshold." ::= { winlink1000HbsAirConf 3 } winlink1000HbsAirConfBEPercentage OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "BE allocation percentage from the total resources (DownLink|UpLink|)." ::= { winlink1000HbsAirConf 4 } -- ########################################################### -- Sector Links Table -- ########################################################### winlink1000HbsAirLink OBJECT IDENTIFIER ::= { winlink1000HbsAir 7 } winlink1000HbsAirLinkNumOfLinks OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of links in the links table." ::= { winlink1000HbsAirLink 1 } winlink1000HbsAirLinkTable OBJECT-TYPE SYNTAX SEQUENCE OF Winlink1000HbsAirLinkEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Holds the table for all links in the sector." ::= { winlink1000HbsAirLink 2 } winlink1000HbsAirLinkEntry OBJECT-TYPE SYNTAX Winlink1000HbsAirLinkEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Link table entry." INDEX { winlink1000HbsAirLinkIndex } ::= { winlink1000HbsAirLinkTable 1 } Winlink1000HbsAirLinkEntry ::= SEQUENCE { winlink1000HbsAirLinkIndex INTEGER, winlink1000HbsAirLinkHsuId INTEGER, winlink1000HbsAirLinkState INTEGER, winlink1000HbsAirLinkWorkingMode INTEGER, winlink1000HbsAirLinkSessionId INTEGER, winlink1000HbsAirLinkHbsEstTput INTEGER, winlink1000HbsAirLinkHsuEstTput INTEGER, winlink1000HbsAirLinkRange INTEGER, winlink1000HbsAirLinkHbsRss INTEGER, winlink1000HbsAirLinkHbsRssBal INTEGER, winlink1000HbsAirLinkHsuRss INTEGER, winlink1000HbsAirLinkHsuRssBal INTEGER, winlink1000HbsAirLinkHsuSerial DisplayString, winlink1000HbsAirLinkTxOperMode INTEGER, winlink1000HbsAirHsuInBytes INTEGER, winlink1000HbsAirHsuOutBytes INTEGER, winlink1000HbsAirHsuInFrames INTEGER, winlink1000HbsAirHsuOutFrames INTEGER, winlink1000HbsAirHsuMacAddress DisplayString, winlink1000HbsAirMaxTputDown INTEGER, winlink1000HbsAirMaxTputUp INTEGER, winlink1000HbsAirLinkCompressedMon OCTET STRING, winlink1000HbsAirLinkCompressedStatic DisplayString, winlink1000HbsAirCpeCapacityLimit INTEGER, winlink1000HbsAirLinkAntennaType INTEGER, winlink1000HbsAirHsuRxRateInKbps INTEGER, winlink1000HbsAirHsuTxRateInKbps INTEGER, winlink1000HbsAirHsuRxRateInFps INTEGER, winlink1000HbsAirHsuTxRateInFps INTEGER, winlink1000HbsAirLinkPeakTputDown INTEGER, winlink1000HbsAirLinkPeakTputUp INTEGER, winlink1000HbsAirLinkUtilDownSecRelMill INTEGER, winlink1000HbsAirLinkUtilUpSecRelMill INTEGER, winlink1000HbsAirLinkUtilDownAllocRelMill INTEGER, winlink1000HbsAirLinkUtilUpAllocRelMill INTEGER, winlink1000HbsAirLinkUtilDownTrafficKbps INTEGER, winlink1000HbsAirLinkUtilUpTrafficKbps INTEGER, winlink1000HbsAirLinkUtilCompressedMon OCTET STRING, winlink1000HbsAirLinkBsaAzimuth INTEGER, winlink1000HbsAirLink1588TCPerformance INTEGER, winlink1000HbsAirLinkSyncEPerformance INTEGER, winlink1000HbsAirHsuTxBytes Counter, winlink1000HbsAirHsuRxBytes Counter } winlink1000HbsAirLinkIndex OBJECT-TYPE SYNTAX INTEGER (0..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "HSUs configuration table index." ::= { winlink1000HbsAirLinkEntry 1 } winlink1000HbsAirLinkHsuId OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "HSU ID of specific link (if registered). Unregistered links have -1." ::= { winlink1000HbsAirLinkEntry 2 } winlink1000HbsAirLinkState OBJECT-TYPE SYNTAX INTEGER { noSync (1), violated (2), syncUnregistered (3), syncRegistered (4), authenticationError (5), swUpgradeRequired (6), syncRegisteredPassive (7), syncRegisteredALP (8) } ACCESS read-only STATUS mandatory DESCRIPTION "Holds the state of specific link." ::= { winlink1000HbsAirLinkEntry 3 } winlink1000HbsAirLinkWorkingMode OBJECT-TYPE SYNTAX INTEGER { unknown(1), normal(2), fullCompatibilityRemoteUpgradeAvailable(3), fullCompatibilityLocalUpgradeAvailable(4), restrictedCompatibilityRemoteUpgradeRecomended(5), restrictedCompatibilityLocalUpgradeRecomended(6), softwareUpgradeRemoteUpgradeRequired(7), softwareUpgradeLocalUpgradeRequired(8), versionsIncompatibilityRemoteUpgradeRequired(9), versionsIncompatibilityLocalUpgradeRequired(10) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the sub-state within the version compatibility." ::= { winlink1000HbsAirLinkEntry 4 } winlink1000HbsAirLinkSessionId OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Holds the Session ID of the link." ::= { winlink1000HbsAirLinkEntry 5 } winlink1000HbsAirLinkHbsEstTput OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Holds the Estimated throughput from the HBS to the HSU." ::= { winlink1000HbsAirLinkEntry 6 } winlink1000HbsAirLinkHsuEstTput OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Holds the Estimated throughput from the HSU to the HBS." ::= { winlink1000HbsAirLinkEntry 7 } winlink1000HbsAirLinkRange OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Holds the range of specific link." ::= { winlink1000HbsAirLinkEntry 8 } winlink1000HbsAirLinkHbsRss OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Holds the RSS of specific link (HBS side)." ::= { winlink1000HbsAirLinkEntry 9 } winlink1000HbsAirLinkHbsRssBal OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Holds the RSS Balance of specific link (HBS side). -2 : Radio 2 RSS is much stronger than Radio 1 RSS. -1 : Radio 2 RSS is stronger than Radio 1 RSS. -0 : Radio 2 RSS is equal to Radio 1 RSS. 1 : Radio 1 RSS is stronger than Radio 2 RSS. 2 : Radio 1 RSS is much stronger than Radio 2 RSS." ::= { winlink1000HbsAirLinkEntry 10 } winlink1000HbsAirLinkHsuRss OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Holds the RSS of specific link (HSU side)." ::= { winlink1000HbsAirLinkEntry 11 } winlink1000HbsAirLinkHsuRssBal OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Holds the RSS Balance of specific link (HSU side). -2 : Radio 2 RSS is much stronger than Radio 1 RSS. -1 : Radio 2 RSS is stronger than Radio 1 RSS. -0 : Radio 2 RSS is equal to Radio 1 RSS. 1 : Radio 1 RSS is stronger than Radio 2 RSS. 2 : Radio 1 RSS is much stronger than Radio 2 RSS." ::= { winlink1000HbsAirLinkEntry 12 } winlink1000HbsAirLinkHsuSerial OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Holds the serial number for specific HSU." ::= { winlink1000HbsAirLinkEntry 13 } winlink1000HbsAirLinkTxOperMode OBJECT-TYPE SYNTAX INTEGER { regularMode (1), measurementMode (2) } ACCESS read-only STATUS mandatory DESCRIPTION "Holds the TX operation mode." ::= { winlink1000HbsAirLinkEntry 14 } winlink1000HbsAirHsuInBytes OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of frames received in the HSU Lan port." ::= { winlink1000HbsAirLinkEntry 15 } winlink1000HbsAirHsuOutBytes OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of frames transmitted from the HSU Lan port." ::= { winlink1000HbsAirLinkEntry 16 } winlink1000HbsAirHsuInFrames OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of bytes received in the HSU Lan port." ::= { winlink1000HbsAirLinkEntry 17 } winlink1000HbsAirHsuOutFrames OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of bytes transmitted from the HSU Lan port." ::= { winlink1000HbsAirLinkEntry 18 } winlink1000HbsAirHsuMacAddress OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "HSU MAC Address." ::= { winlink1000HbsAirLinkEntry 19 } winlink1000HbsAirMaxTputDown OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Max Throughput Downlink." ::= { winlink1000HbsAirLinkEntry 20 } winlink1000HbsAirMaxTputUp OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Max Throughput Uplink." ::= { winlink1000HbsAirLinkEntry 21 } winlink1000HbsAirLinkCompressedMon OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Holds all the link information in compressed binary (Bytes/octets). Fields included (size in bytes): Link State(1) Link Working Mode(1) Session Id(4) HBS Est. Tput(4) HSU Est. Tput(4) HBS Rss(1) HBS Rss Balance(1) HSU Rss(1) HSU Rss Balance(1) Tx Operation Mode(1) HSU In Bytes(4) HSU Out Bytes(4) HSU In Frames(4) HSU Out Frames(4) HSU ID (1 bytes) HSU Rx Rate In Kbps (4) HSU Tx Rate In Kbps (4) HSU Rx Rate In Fps (4) HSU Tx Rate In Fps (4) Peak throughput in the DL direction (4) Peak throughput in the UL direction (4) Number of local changes at HSU(1) Alignment Status(1) HBS Chain 1 Rss(1) HBS Chain 2 Rss(1) HBS Chain 3 Rss(1) HSU Chain 1 Rss(1) HSU Chain 2 Rss(1) HSU Chain 3 Rss(1) HSU Current Rate Index (2 bytes) HSU Current Rate CBW (1 bytes) HSU Current Rate GI (1 bytes) HBS Current Rate Index (2 bytes) HBS Current Rate CBW (1 bytes) HBS Current Rate GI (1 bytes) Bsa Azimuth(2) HSU LAN 1 Rx Rate In Kbps (4) HSU LAN 1 Tx Rate In Kbps (4) HSU LAN 1 Rx Rate In Fps (4) HSU LAN 1 Tx Rate In Fps (4) HSU LAN 2 Rx Rate In Kbps (4) HSU LAN 2 Tx Rate In Kbps (4) HSU LAN 2 Rx Rate In Fps (4) HSU LAN 2 Tx Rate In Fps (4) 1588TC Performance(1) SyncE Performance(1) ATPC status (1) HBS Speed(4) HSU Speed(4) Link Quality DL (4) Link Quality UL (4) IGMP MG Per CPE(2) " ::= { winlink1000HbsAirLinkEntry 22 } winlink1000HbsAirLinkCompressedStatic OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Holds all the configuration data of this link in compressed format. Helps the NMS to get info regarding new Unregistered links. Fields Included: SessionID (4 bytes) HSU IP address (4 bytes) HSU Name (32 bytes) HSU Location (32 bytes) HSU Serial number (16 bytes) HSU MAC Address (12 bytes) Air Link Range Max Throughput Down (4 bytes) Max Throughput Up. (4 bytes) Cpacity Limit (4 bytes) HSU Antenna type (1 byte) Aggregate Capacity (4 bytes) 1588TC supported (1 byte) SyncE supported (1 byte) Carrier ID" ::= { winlink1000HbsAirLinkEntry 23 } winlink1000HbsAirCpeCapacityLimit OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Capacity Limit in Kilo bit per second." ::= { winlink1000HbsAirLinkEntry 24 } winlink1000HbsAirLinkAntennaType OBJECT-TYPE SYNTAX INTEGER { single(1), dual(2), undefined(3), triple(4) } ACCESS read-only STATUS mandatory DESCRIPTION "HSU External Antenna Type: Monopolar or Bipolar." ::= { winlink1000HbsAirLinkEntry 25 } winlink1000HbsAirHsuRxRateInKbps OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "HSU Rx Rate in Kbps." ::= { winlink1000HbsAirLinkEntry 26 } winlink1000HbsAirHsuTxRateInKbps OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "HSU Tx Rate in Kbps." ::= { winlink1000HbsAirLinkEntry 27 } winlink1000HbsAirHsuRxRateInFps OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "HSU Tx Rate in Fps." ::= { winlink1000HbsAirLinkEntry 28 } winlink1000HbsAirHsuTxRateInFps OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "HSU Tx Rate in Fps." ::= { winlink1000HbsAirLinkEntry 29 } winlink1000HbsAirLinkPeakTputDown OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Peak throughput in the DL direction (kbps)." ::= { winlink1000HbsAirLinkEntry 30 } winlink1000HbsAirLinkPeakTputUp OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Peak throughput in the UL direction (kbps)." ::= { winlink1000HbsAirLinkEntry 31 } winlink1000HbsAirLinkUtilDownSecRelMill OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The average time percentage (in thousandths), out of the BTS DL capability, that was used for transmitting data to the SU." ::= { winlink1000HbsAirLinkEntry 32 } winlink1000HbsAirLinkUtilUpSecRelMill OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The average time percentage (in thousandths), out of the BTS UL capability, that was used for receiving data from the SU." ::= { winlink1000HbsAirLinkEntry 33 } winlink1000HbsAirLinkUtilDownAllocRelMill OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The time percentage (in thousandths), relative to the SU DL allocation, that was used for transmitting data to the SU." ::= { winlink1000HbsAirLinkEntry 34 } winlink1000HbsAirLinkUtilUpAllocRelMill OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The time percentage (in thousandths), relative to the SU UL allocation, that was used for receiving data from the SU." ::= { winlink1000HbsAirLinkEntry 35 } winlink1000HbsAirLinkUtilDownTrafficKbps OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Average data throughput (Exported in Kbps) transmitted in the DL towards the SU during the last second." ::= { winlink1000HbsAirLinkEntry 36 } winlink1000HbsAirLinkUtilUpTrafficKbps OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Average data throughput (Exported in Kbps) received in the UL from the SU during the last second." ::= { winlink1000HbsAirLinkEntry 37 } winlink1000HbsAirLinkUtilCompressedMon OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "One string that holds the 6 Utilization per link values: DownSecRel (2 bytes) UpSecRel (2 bytes) DownAllocRel (4 bytes) UpAllocRel (4 bytes) DownTraffic (4 bytes) UpTraffic (4 bytes)." ::= { winlink1000HbsAirLinkEntry 38 } winlink1000HbsAirLinkBsaAzimuth OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Absolute (geographical) azimuth of the HSU (looking from HBS site)." ::= { winlink1000HbsAirLinkEntry 39 } winlink1000HbsAirLink1588TCPerformance OBJECT-TYPE SYNTAX INTEGER { high (1), low (2), notApplicable (3) } ACCESS read-only STATUS mandatory DESCRIPTION "TC performance." ::= { winlink1000HbsAirLinkEntry 40 } winlink1000HbsAirLinkSyncEPerformance OBJECT-TYPE SYNTAX INTEGER { high (1), low (2), holdover (3), syncEFailure (4), notApplicable (5), refClk (6) } ACCESS read-only STATUS mandatory DESCRIPTION "SyncE performance." ::= { winlink1000HbsAirLinkEntry 41 } winlink1000HbsAirHsuTxBytes OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Accumulated Tx Bytes per link." ::= { winlink1000HbsAirLinkEntry 42 } winlink1000HbsAirHsuRxBytes OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Accumulated Rx Bytes per link." ::= { winlink1000HbsAirLinkEntry 43 } winlink1000HbsAirComboSwitchSectorFreqBandId OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Switch Frequency band for the whole sector." ::= { winlink1000HbsAir 8 } winlink1000HbsAirGeoAzimuth OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Geographic sector azimuth in degrees * 10." ::= { winlink1000HbsAir 9 } winlink1000HbsAirGeoBeamwidth OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Geographic sector beamwidth in degrees * 10." ::= { winlink1000HbsAir 10 } winlink1000HbsAirMaxDistanceMetersMobility OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Maximum distance in meters. Used by Mobility links only." ::= { winlink1000HbsAir 11 } winlink1000HbsAirComboSwitchSectorFreqBandIdStr OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Switch Frequency band for the whole sector, overriding some of the Combo parameters." ::= { winlink1000HbsAir 12 } winlink1000HbsAirTimeSlotAllocationBitmap OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Time Slots Allocation Bitmap for the entire sector (Hex Value)." ::= { winlink1000HbsAir 13 } winlink1000HbsAirAvailTimeSlotsUp OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This parameter holds the number of available UL time slots (not in use) in the air interface." ::= { winlink1000HbsAir 14 } winlink1000HbsAirDownUtilMill OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Sector Air Interface utilization in the Downlink direction (thousandths). Average time percentage, out of the entire BTS DL capability, that was used for transmitting data to all the SUs." ::= { winlink1000HbsAir 15 } winlink1000HbsAirUpUtilMill OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Sector Air Interface utilization in the Uplink direction (thousandths). The average number of timeslots that were used in the UL (by all the links) out of the entire number of timeslots." ::= { winlink1000HbsAir 16 } winlink1000HbsAirDownTrafficKbps OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Average data throughput (expressed in Kbps) transmitted in the DL towards all the SUs during the last second." ::= { winlink1000HbsAir 17 } winlink1000HbsAirUpTrafficKbps OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Average data throughput (expressed in Kbps) received in the UL from all the SUs during the last second." ::= { winlink1000HbsAir 18 } winlink1000HbsAirCompressedMonSec OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "One string that holds the 4 Utilization per Sector values: DownUtil (2 bytes), UpUtil (2 bytes), DownTraffic (4 bytes), UpTraffic (4 bytes)." ::= { winlink1000HbsAir 19 } winlink1000HbsAirDelayVsTputOpt OBJECT-TYPE SYNTAX INTEGER { delaySensitivity(1), throughputOptimized(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Delay vs. Throughput optimization type: 1 = Delay sensitivity 2 = Throughput optimized" ::= { winlink1000HbsAir 20 } winlink1000HbsAirUCBP OBJECT IDENTIFIER ::= { winlink1000HbsAir 21 } -- ########################################################### -- UCBP section -- ########################################################### winlink1000HbsAirUCBPMinCS OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Minimal contention slot length used for UCBP algorithm (in ms.) between 5-20ms." ::= { winlink1000HbsAirUCBP 1 } winlink1000HbsAirUCBPSharingPercentage OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Sharing percentage used by UCBP algorithm (15-75)" ::= { winlink1000HbsAirUCBP 2 } winlink1000HbsAirSingleHsuMode OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), singleHsu(2), multipleHsus(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Single HSU mode: 1 = Not Applicable 2 = Single HSU 3 = Multiple HSUs" ::= { winlink1000HbsAir 22 } winlink1000HbsAirMobilityAzTrack OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Azimuth tracking for mobility status: 1 = Not applicable 2 = Active 3 = Impossible" ::= { winlink1000HbsAir 23 } winlink1000HbsAirSyncEPerformance OBJECT-TYPE SYNTAX INTEGER { high (1), low (2), holdover (3), syncEFailure (4), notApplicable (5), refClk (6) } ACCESS read-only STATUS mandatory DESCRIPTION "SyncE performance when HBS is not reference clock" ::= { winlink1000HbsAir 24 } winlink1000HbsAirAtpcEnable OBJECT-TYPE SYNTAX INTEGER { off (1), static (2), dynamic (3), notSupported (4) } ACCESS read-write STATUS mandatory DESCRIPTION "ATPC mode (off, static or dynamic) status" ::= { winlink1000HbsAir 25 } winlink1000HbsAirAtpcTargetMCS OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "targetRate for ATPC operation (100-309)" ::= { winlink1000HbsAir 26 } winlink1000HbsAirAtpcMaxAllowedRate OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Max allowed rate (will be 207 for N products and 209 for AC products)" ::= { winlink1000HbsAir 27 } -- ########################################################### -- ATPC target Rss Per Rate -- ########################################################### winlink1000HbsAirAtpcTargetRSSPerRateTable OBJECT-TYPE SYNTAX SEQUENCE OF Winlink1000HbsAirAtpcMaxAllowedRateEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of Atpc Target Rss Per Rate." ::= { winlink1000HbsAir 28 } winlink1000HbsAirAtpcMaxAllowedRateEntry OBJECT-TYPE SYNTAX Winlink1000HbsAirAtpcMaxAllowedRateEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Atpc Target Rss Per Rate table entry." INDEX { winlink1000HbsAirAtpcTargetRSSPerRateIndex } ::= { winlink1000HbsAirAtpcTargetRSSPerRateTable 1 } Winlink1000HbsAirAtpcMaxAllowedRateEntry ::= SEQUENCE { winlink1000HbsAirAtpcTargetRSSPerRateIndex INTEGER, winlink1000HbsAirAtpcTargetRSSPerRate INTEGER } winlink1000HbsAirAtpcTargetRSSPerRateIndex OBJECT-TYPE SYNTAX INTEGER (0..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "Atpc Target Rss Per Rate Index." ::= { winlink1000HbsAirAtpcMaxAllowedRateEntry 1 } winlink1000HbsAirAtpcTargetRSSPerRate OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Atpc Target Rss Per Rate value." ::= { winlink1000HbsAirAtpcMaxAllowedRateEntry 2 } winlink1000HbsAirMinimalTimeBetweenAutoRealignment OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Minimal time in seconds between two Automatic Realignment Processes" ::= { winlink1000HbsAir 29 } winlink1000HbsAirAvailResourcesDL OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This parameter holds the number of available DL Resources (not in use) in the air interface." ::= { winlink1000HbsAir 30 } winlink1000HbsAirAvailResourcesUL OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This parameter holds the number of available UL Resources (not in use) in the air interface." ::= { winlink1000HbsAir 31 } winlink1000HbsAirHbsType OBJECT-TYPE SYNTAX INTEGER { carrier (1), residential (2) } ACCESS read-only STATUS mandatory DESCRIPTION "HBSs Service Type Category " ::= { winlink1000HbsAir 32 } winlink1000HbsAirLinkQuality OBJECT IDENTIFIER ::= { winlink1000HbsAir 33 } -- ########################################################### -- Link Quality section -- ########################################################### winlink1000HbsAirLinkQualitySupport OBJECT-TYPE SYNTAX INTEGER { notSupported (1), supported (2) } ACCESS read-only STATUS mandatory DESCRIPTION "Link quality detection support." ::= { winlink1000HbsAirLinkQuality 1 } winlink1000HbsAirLinkQualityActivationStatus OBJECT-TYPE SYNTAX INTEGER { disabled (1), enabled (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Link quality detection sector activation status." ::= { winlink1000HbsAirLinkQuality 2 } winlink1000HbsAirLinkQualityDetectionTime OBJECT-TYPE SYNTAX INTEGER (60..900) ACCESS read-write STATUS mandatory DESCRIPTION "Link quality detection time in seconds." ::= { winlink1000HbsAirLinkQuality 3 } winlink1000HbsAirLinkQualityDetectionThreshold OBJECT-TYPE SYNTAX INTEGER (5..100) ACCESS read-write STATUS mandatory DESCRIPTION "Link quality detection threshold in percentage." ::= { winlink1000HbsAirLinkQuality 4 } winlink1000HbsAirAggregatedDownlinkUtil OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Aggregated Downlink Utilization per sector" ::= { winlink1000HbsAir 34 } winlink1000HbsAirAggregatedUplinkUtil OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Aggregated Uplink Utilization per sector" ::= { winlink1000HbsAir 35 } winlink1000HbsAirAggregatedReferenceCounter OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Aggregated Down link Reference counter per sector (units are symbols)" ::= { winlink1000HbsAir 36 } winlink1000HbsAirRegisteredCpeTable OBJECT-TYPE SYNTAX SEQUENCE OF Winlink1000HbsAirRegisteredCpeTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Holds the table for all CPEs in the sector." ::= { winlink1000HbsAir 37 } winlink1000HbsAirRegisteredCpeTableEntry OBJECT-TYPE SYNTAX Winlink1000HbsAirRegisteredCpeTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Link table entry." INDEX { winlink1000HbsAirRegisteredCpeTableIndex } ::= { winlink1000HbsAirRegisteredCpeTable 1 } Winlink1000HbsAirRegisteredCpeTableEntry ::= SEQUENCE { winlink1000HbsAirRegisteredCpeTableIndex INTEGER, winlink1000HbsAirRegisteredCpeLinkId INTEGER, winlink1000HbsAirRegisteredCpeState INTEGER, winlink1000HbsAirRegisteredCpeWorkingMode INTEGER, winlink1000HbsAirRegisteredCpeSessionId INTEGER, winlink1000HbsAirRegisteredCpeHbsEstTput INTEGER, winlink1000HbsAirRegisteredCpeHsuEstTput INTEGER, winlink1000HbsAirRegisteredCpeRange INTEGER, winlink1000HbsAirRegisteredCpeHbsRss INTEGER, winlink1000HbsAirRegisteredCpeHbsRssBal INTEGER, winlink1000HbsAirRegisteredCpeHsuRss INTEGER, winlink1000HbsAirRegisteredCpeHsuRssBal INTEGER, winlink1000HbsAirRegisteredCpeHsuSerial DisplayString, winlink1000HbsAirRegisteredCpeTxOperMode INTEGER, winlink1000HbsAirRegisteredCpeHsuInBytes INTEGER, winlink1000HbsAirRegisteredCpeHsuOutBytes INTEGER, winlink1000HbsAirRegisteredCpeHsuInFrames INTEGER, winlink1000HbsAirRegisteredCpeHsuOutFrames INTEGER, winlink1000HbsAirRegisteredCpeHsuMacAddress DisplayString, winlink1000HbsAirRegisteredCpeMaxTputDown INTEGER, winlink1000HbsAirRegisteredCpeMaxTputUp INTEGER, winlink1000HbsAirRegisteredCpeCompressedMon OCTET STRING, winlink1000HbsAirRegisteredCpeCompressedStatic DisplayString, winlink1000HbsAirRegisteredCpeCpeCapacityLimit INTEGER, winlink1000HbsAirRegisteredCpeAntennaType INTEGER, winlink1000HbsAirRegisteredCpeHsuRxRateInKbps INTEGER, winlink1000HbsAirRegisteredCpeHsuTxRateInKbps INTEGER, winlink1000HbsAirRegisteredCpeHsuRxRateInFps INTEGER, winlink1000HbsAirRegisteredCpeHsuTxRateInFps INTEGER, winlink1000HbsAirRegisteredCpePeakTputDown INTEGER, winlink1000HbsAirRegisteredCpePeakTputUp INTEGER, winlink1000HbsAirRegisteredCpeUtilDownSecRelMill INTEGER, winlink1000HbsAirRegisteredCpeUtilUpSecRelMill INTEGER, winlink1000HbsAirRegisteredCpeUtilDownAllocRelMill INTEGER, winlink1000HbsAirRegisteredCpeUtilUpAllocRelMill INTEGER, winlink1000HbsAirRegisteredCpeUtilDownTrafficKbps INTEGER, winlink1000HbsAirRegisteredCpeUtilUpTrafficKbps INTEGER, winlink1000HbsAirRegisteredCpeUtilCompressedMon OCTET STRING, winlink1000HbsAirRegisteredCpeBsaAzimuth INTEGER, winlink1000HbsAirRegisteredCpe1588TCPerformance INTEGER, winlink1000HbsAirRegisteredCpeSyncEPerformance INTEGER, winlink1000HbsAirRegisteredCpeProductName DisplayString, winlink1000HbsAirRegisteredCpeIpAddress DisplayString, winlink1000HbsAirRegisteredCpeIpAddressV6 DisplayString, winlink1000HbsAirRegisteredCpeCarrierId INTEGER } winlink1000HbsAirRegisteredCpeTableIndex OBJECT-TYPE SYNTAX INTEGER (0..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "HSUs configuration table index." ::= { winlink1000HbsAirRegisteredCpeTableEntry 1 } winlink1000HbsAirRegisteredCpeLinkId OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Link ID of specific HSU (if active link). inactive links have 255." ::= { winlink1000HbsAirRegisteredCpeTableEntry 2 } winlink1000HbsAirRegisteredCpeState OBJECT-TYPE SYNTAX INTEGER { noSync (1), violated (2), syncUnregistered (3), syncRegistered (4), authenticationError (5), swUpgradeRequired (6), syncRegisteredPassive (7), syncRegisteredALP (8) } ACCESS read-only STATUS mandatory DESCRIPTION "Holds the state of specific link." ::= { winlink1000HbsAirRegisteredCpeTableEntry 3 } winlink1000HbsAirRegisteredCpeWorkingMode OBJECT-TYPE SYNTAX INTEGER { unknown(1), normal(2), fullCompatibilityRemoteUpgradeAvailable(3), fullCompatibilityLocalUpgradeAvailable(4), restrictedCompatibilityRemoteUpgradeRecomended(5), restrictedCompatibilityLocalUpgradeRecomended(6), softwareUpgradeRemoteUpgradeRequired(7), softwareUpgradeLocalUpgradeRequired(8), versionsIncompatibilityRemoteUpgradeRequired(9), versionsIncompatibilityLocalUpgradeRequired(10) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the sub-state within the version compatibility." ::= { winlink1000HbsAirRegisteredCpeTableEntry 4 } winlink1000HbsAirRegisteredCpeSessionId OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Holds the Session ID of the link." ::= { winlink1000HbsAirRegisteredCpeTableEntry 5 } winlink1000HbsAirRegisteredCpeHbsEstTput OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Holds the Estimated throughput from the HBS to the HSU." ::= { winlink1000HbsAirRegisteredCpeTableEntry 6 } winlink1000HbsAirRegisteredCpeHsuEstTput OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Holds the Estimated throughput from the HSU to the HBS." ::= { winlink1000HbsAirRegisteredCpeTableEntry 7 } winlink1000HbsAirRegisteredCpeRange OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Holds the range of specific link." ::= { winlink1000HbsAirRegisteredCpeTableEntry 8 } winlink1000HbsAirRegisteredCpeHbsRss OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Holds the RSS of specific link (HBS side)." ::= { winlink1000HbsAirRegisteredCpeTableEntry 9 } winlink1000HbsAirRegisteredCpeHbsRssBal OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Holds the RSS Balance of specific link (HBS side). -2 : Radio 2 RSS is much stronger than Radio 1 RSS. -1 : Radio 2 RSS is stronger than Radio 1 RSS. -0 : Radio 2 RSS is equal to Radio 1 RSS. 1 : Radio 1 RSS is stronger than Radio 2 RSS. 2 : Radio 1 RSS is much stronger than Radio 2 RSS." ::= { winlink1000HbsAirRegisteredCpeTableEntry 10 } winlink1000HbsAirRegisteredCpeHsuRss OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Holds the RSS of specific link (HSU side)." ::= { winlink1000HbsAirRegisteredCpeTableEntry 11 } winlink1000HbsAirRegisteredCpeHsuRssBal OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Holds the RSS Balance of specific link (HSU side). -2 : Radio 2 RSS is much stronger than Radio 1 RSS. -1 : Radio 2 RSS is stronger than Radio 1 RSS. -0 : Radio 2 RSS is equal to Radio 1 RSS. 1 : Radio 1 RSS is stronger than Radio 2 RSS. 2 : Radio 1 RSS is much stronger than Radio 2 RSS." ::= { winlink1000HbsAirRegisteredCpeTableEntry 12 } winlink1000HbsAirRegisteredCpeHsuSerial OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Holds the serial number for specific HSU." ::= { winlink1000HbsAirRegisteredCpeTableEntry 13 } winlink1000HbsAirRegisteredCpeTxOperMode OBJECT-TYPE SYNTAX INTEGER { regularMode (1), measurementMode (2) } ACCESS read-only STATUS mandatory DESCRIPTION "Holds the TX operation mode." ::= { winlink1000HbsAirRegisteredCpeTableEntry 14 } winlink1000HbsAirRegisteredCpeHsuInBytes OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of frames received in the HSU Lan port." ::= { winlink1000HbsAirRegisteredCpeTableEntry 15 } winlink1000HbsAirRegisteredCpeHsuOutBytes OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of frames transmitted from the HSU Lan port." ::= { winlink1000HbsAirRegisteredCpeTableEntry 16 } winlink1000HbsAirRegisteredCpeHsuInFrames OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of bytes received in the HSU Lan port." ::= { winlink1000HbsAirRegisteredCpeTableEntry 17 } winlink1000HbsAirRegisteredCpeHsuOutFrames OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of bytes transmitted from the HSU Lan port." ::= { winlink1000HbsAirRegisteredCpeTableEntry 18 } winlink1000HbsAirRegisteredCpeHsuMacAddress OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "HSU MAC Address." ::= { winlink1000HbsAirRegisteredCpeTableEntry 19 } winlink1000HbsAirRegisteredCpeMaxTputDown OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Max Throughput Downlink." ::= { winlink1000HbsAirRegisteredCpeTableEntry 20 } winlink1000HbsAirRegisteredCpeMaxTputUp OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Max Throughput Uplink." ::= { winlink1000HbsAirRegisteredCpeTableEntry 21 } winlink1000HbsAirRegisteredCpeCompressedMon OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Holds all the link information in compressed binary (Bytes/octets). Fields included (size in bytes): Link State(1) Link Working Mode(1) Session Id(4) HBS Est. Tput(4) HSU Est. Tput(4) HBS Rss(1) HBS Rss Balance(1) HSU Rss(1) HSU Rss Balance(1) Tx Operation Mode(1) HSU In Bytes(4) HSU Out Bytes(4) HSU In Frames(4) HSU Out Frames(4) HSU ID (1 bytes) HSU Rx Rate In Kbps (4) HSU Tx Rate In Kbps (4) HSU Rx Rate In Fps (4) HSU Tx Rate In Fps (4) Peak throughput in the DL direction (4) Peak throughput in the UL direction (4) Number of local changes at HSU(1) Alignment Status(1) HBS Chain 1 Rss(1) HBS Chain 2 Rss(1) HBS Chain 3 Rss(1) HSU Chain 1 Rss(1) HSU Chain 2 Rss(1) HSU Chain 3 Rss(1) HSU Current Rate Index (2 bytes) HSU Current Rate CBW (1 bytes) HSU Current Rate GI (1 bytes) HBS Current Rate Index (2 bytes) HBS Current Rate CBW (1 bytes) HBS Current Rate GI (1 bytes) Bsa Azimuth(2) HSU LAN 1 Rx Rate In Kbps (4) HSU LAN 1 Tx Rate In Kbps (4) HSU LAN 1 Rx Rate In Fps (4) HSU LAN 1 Tx Rate In Fps (4) HSU LAN 2 Rx Rate In Kbps (4) HSU LAN 2 Tx Rate In Kbps (4) HSU LAN 2 Rx Rate In Fps (4) HSU LAN 2 Tx Rate In Fps (4) 1588TC Performance(1) SyncE Performance(1) ATPC status (1) HBS Speed(4) HSU Speed(4) IGMP MG Per CPE(2) Reserved(1) " ::= { winlink1000HbsAirRegisteredCpeTableEntry 22 } winlink1000HbsAirRegisteredCpeCompressedStatic OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Holds all the configuration data of this link in compressed format. Helps the NMS to get info regarding new Unregistered links. Fields Included: SessionID (4 bytes) HSU IP address (4 bytes) HSU Name (32 bytes) HSU Location (32 bytes) HSU Serial number (16 bytes) HSU MAC Address (12 bytes) Air Link Range Max Throughput Down (4 bytes) Max Throughput Up. (4 bytes) Cpacity Limit (4 bytes) HSU Antenna type (1 byte) Aggregate Capacity (4 bytes) 1588TC supported (1 byte) SyncE supported (1 byte) Carrier ID (4 byte) SW version (10 byte) HW version (40 byte)" ::= { winlink1000HbsAirRegisteredCpeTableEntry 23 } winlink1000HbsAirRegisteredCpeCpeCapacityLimit OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Capacity Limit in Kilo bit per second." ::= { winlink1000HbsAirRegisteredCpeTableEntry 24 } winlink1000HbsAirRegisteredCpeAntennaType OBJECT-TYPE SYNTAX INTEGER { single(1), dual(2), undefined(3), triple(4) } ACCESS read-only STATUS mandatory DESCRIPTION "HSU External Antenna Type: Monopolar or Bipolar." ::= { winlink1000HbsAirRegisteredCpeTableEntry 25 } winlink1000HbsAirRegisteredCpeHsuRxRateInKbps OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "HSU Rx Rate in Kbps." ::= { winlink1000HbsAirRegisteredCpeTableEntry 26 } winlink1000HbsAirRegisteredCpeHsuTxRateInKbps OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "HSU Tx Rate in Kbps." ::= { winlink1000HbsAirRegisteredCpeTableEntry 27 } winlink1000HbsAirRegisteredCpeHsuRxRateInFps OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "HSU Tx Rate in Fps." ::= { winlink1000HbsAirRegisteredCpeTableEntry 28 } winlink1000HbsAirRegisteredCpeHsuTxRateInFps OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "HSU Tx Rate in Fps." ::= { winlink1000HbsAirRegisteredCpeTableEntry 29 } winlink1000HbsAirRegisteredCpePeakTputDown OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Peak throughput in the DL direction (kbps)." ::= { winlink1000HbsAirRegisteredCpeTableEntry 30 } winlink1000HbsAirRegisteredCpePeakTputUp OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Peak throughput in the UL direction (kbps)." ::= { winlink1000HbsAirRegisteredCpeTableEntry 31 } winlink1000HbsAirRegisteredCpeUtilDownSecRelMill OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The average time percentage (in thousandths), out of the BTS DL capability, that was used for transmitting data to the SU." ::= { winlink1000HbsAirRegisteredCpeTableEntry 32 } winlink1000HbsAirRegisteredCpeUtilUpSecRelMill OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The average time percentage (in thousandths), out of the BTS UL capability, that was used for receiving data from the SU." ::= { winlink1000HbsAirRegisteredCpeTableEntry 33 } winlink1000HbsAirRegisteredCpeUtilDownAllocRelMill OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The time percentage (in thousandths), relative to the SU DL allocation, that was used for transmitting data to the SU." ::= { winlink1000HbsAirRegisteredCpeTableEntry 34 } winlink1000HbsAirRegisteredCpeUtilUpAllocRelMill OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The time percentage (in thousandths), relative to the SU UL allocation, that was used for receiving data from the SU." ::= { winlink1000HbsAirRegisteredCpeTableEntry 35 } winlink1000HbsAirRegisteredCpeUtilDownTrafficKbps OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Average data throughput (Exported in Kbps) transmitted in the DL towards the SU during the last second." ::= { winlink1000HbsAirRegisteredCpeTableEntry 36 } winlink1000HbsAirRegisteredCpeUtilUpTrafficKbps OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Average data throughput (Exported in Kbps) received in the UL from the SU during the last second." ::= { winlink1000HbsAirRegisteredCpeTableEntry 37 } winlink1000HbsAirRegisteredCpeUtilCompressedMon OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "One string that holds the 6 Utilization per link values: DownSecRel (2 bytes) UpSecRel (2 bytes) DownAllocRel (4 bytes) UpAllocRel (4 bytes) DownTraffic (4 bytes) UpTraffic (4 bytes)." ::= { winlink1000HbsAirRegisteredCpeTableEntry 38 } winlink1000HbsAirRegisteredCpeBsaAzimuth OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Absolute (geographical) azimuth of the HSU (looking from HBS site)." ::= { winlink1000HbsAirRegisteredCpeTableEntry 39 } winlink1000HbsAirRegisteredCpe1588TCPerformance OBJECT-TYPE SYNTAX INTEGER { high (1), low (2), notApplicable (3) } ACCESS read-only STATUS mandatory DESCRIPTION "TC performance." ::= { winlink1000HbsAirRegisteredCpeTableEntry 40 } winlink1000HbsAirRegisteredCpeSyncEPerformance OBJECT-TYPE SYNTAX INTEGER { high (1), low (2), holdover (3), syncEFailure (4), notApplicable (5), refClk (6) } ACCESS read-only STATUS mandatory DESCRIPTION "SyncE performance." ::= { winlink1000HbsAirRegisteredCpeTableEntry 41 } winlink1000HbsAirRegisteredCpeProductName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "HSU Product Name" ::= { winlink1000HbsAirRegisteredCpeTableEntry 42 } winlink1000HbsAirRegisteredCpeIpAddress OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "HSU IP Address" ::= { winlink1000HbsAirRegisteredCpeTableEntry 43 } winlink1000HbsAirRegisteredCpeIpAddressV6 OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "HSU IP Address V6" ::= { winlink1000HbsAirRegisteredCpeTableEntry 44 } winlink1000HbsAirRegisteredCpeCarrierId OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Carrier Id" ::= { winlink1000HbsAirRegisteredCpeTableEntry 45 } winlink1000HbsAirNumberOfRegisteredCpes OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of registered HSUs." ::= { winlink1000HbsAir 38 } winlink1000HbsAirNumberOfRegisteredActiveCpes OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of registered active HSUs." ::= { winlink1000HbsAir 39 } -- ########################################################### -- Hbs Carrier Table -- ########################################################### winlink1000HbsAirCarrierTable OBJECT-TYPE SYNTAX SEQUENCE OF Winlink1000HbsAirCarrierEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Carrier-specific attributes that are not band-specific" ::= { winlink1000HbsAir 40 } winlink1000HbsAirCarrierEntry OBJECT-TYPE SYNTAX Winlink1000HbsAirCarrierEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Carrier table entry." INDEX { winlink1000HbsAirCarrierIndex } ::= { winlink1000HbsAirCarrierTable 1 } Winlink1000HbsAirCarrierEntry ::= SEQUENCE { winlink1000HbsAirCarrierIndex INTEGER, winlink1000HbsAirCarrierState INTEGER, winlink1000HbsAirCarrierOpMode INTEGER, winlink1000HbsAirCarrierSectorCbwSupportedStr DisplayString, winlink1000HbsAirCarrierComboSwitchSectorFreqBandIdStr DisplayString, winlink1000HbsAirCarrierDelayVsTputOpt INTEGER, winlink1000HbsAirCarrierAtpcEnable INTEGER, winlink1000HbsAirCarrierAtpcTargetMCS INTEGER, winlink1000HbsAirCarrierAtpcMaxAllowedRate INTEGER, winlink1000HbsAirCarrierAvailResourcesDL INTEGER, winlink1000HbsAirCarrierAvailResourcesUL INTEGER, winlink1000HbsAirCarrierBEPercentage DisplayString, winlink1000HbsAirCarrierMaxNumOfBeHsus INTEGER } winlink1000HbsAirCarrierIndex OBJECT-TYPE SYNTAX INTEGER { carrier1(1), carrier2(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Carrier index." ::= { winlink1000HbsAirCarrierEntry 1 } winlink1000HbsAirCarrierState OBJECT-TYPE SYNTAX INTEGER { init (1), bitFailed (2), inactive (3), spectrumMeasurement (4), scanning (5), cac (6), transceiving (7), standBy (8), rawAlignment (9) } ACCESS read-only STATUS mandatory DESCRIPTION "Holds the state of the HBS." ::= { winlink1000HbsAirCarrierEntry 2 } winlink1000HbsAirCarrierOpMode OBJECT-TYPE SYNTAX INTEGER { inactive (1), active (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Holds the operation mode of the HBS." ::= { winlink1000HbsAirCarrierEntry 3 } winlink1000HbsAirCarrierSectorCbwSupportedStr OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Represents the channel bandwidth which is supported by the HBS and all connected HSUs." ::= { winlink1000HbsAirCarrierEntry 4 } winlink1000HbsAirCarrierComboSwitchSectorFreqBandIdStr OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Switch Frequency band for the whole sector, overriding some of the Combo parameters." ::= { winlink1000HbsAirCarrierEntry 5 } winlink1000HbsAirCarrierDelayVsTputOpt OBJECT-TYPE SYNTAX INTEGER { delaySensitivity(1), throughputOptimized(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Delay vs. Throughput optimization type: 1 = Delay sensitivity 2 = Throughput optimized" ::= { winlink1000HbsAirCarrierEntry 6 } winlink1000HbsAirCarrierAtpcEnable OBJECT-TYPE SYNTAX INTEGER { off (1), static (2), dynamic (3), notSupported (4) } ACCESS read-write STATUS mandatory DESCRIPTION "ATPC mode (off, static or dynamic) status" ::= { winlink1000HbsAirCarrierEntry 7 } winlink1000HbsAirCarrierAtpcTargetMCS OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "targetRate for ATPC operation (100-309)" ::= { winlink1000HbsAirCarrierEntry 8 } winlink1000HbsAirCarrierAtpcMaxAllowedRate OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Max allowed rate (will be 207 for N products and 209 for AC products)" ::= { winlink1000HbsAirCarrierEntry 9 } winlink1000HbsAirCarrierAvailResourcesDL OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This parameter holds the number of available DL Resources (not in use) in the air interface." ::= { winlink1000HbsAirCarrierEntry 10 } winlink1000HbsAirCarrierAvailResourcesUL OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This parameter holds the number of available UL Resources (not in use) in the air interface." ::= { winlink1000HbsAirCarrierEntry 11 } winlink1000HbsAirCarrierBEPercentage OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "BE allocation percentage from the total resources (DownLink|UpLink|)." ::= { winlink1000HbsAirCarrierEntry 12 } winlink1000HbsAirCarrierMaxNumOfBeHsus OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This parameter holds the maximum number of Best Effort Hsus." ::= { winlink1000HbsAirCarrierEntry 13 } winlink1000HbsAirAggregatedReferenceCounterUplink OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Aggregated Up link Reference counter per sector (units are symbols)" ::= { winlink1000HbsAir 41 } -- ########################################################### -- Hbs Carrier Information Table -- ########################################################### winlink1000HbsAirCarrierInformationTable OBJECT-TYPE SYNTAX SEQUENCE OF Winlink1000HbsAirCarrierInformationEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Carrier-specific attributes that are not band-specific" ::= { winlink1000HbsAir 42 } winlink1000HbsAirCarrierInformationEntry OBJECT-TYPE SYNTAX Winlink1000HbsAirCarrierInformationEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Carrier table entry." INDEX { winlink1000HbsAirCarrierInformationIndex } ::= { winlink1000HbsAirCarrierInformationTable 1 } Winlink1000HbsAirCarrierInformationEntry ::= SEQUENCE { winlink1000HbsAirCarrierInformationIndex INTEGER, winlink1000HbsAirCarrierInformationSubBandDescription DisplayString, winlink1000HbsAirCarrierInformationState INTEGER, winlink1000HbsAirCarrierInformationFrequency INTEGER, winlink1000HbsAirCarrierInformationTxPower INTEGER, winlink1000HbsAirCarrierInformationTotalTxPower INTEGER, winlink1000HbsAirCarrierInformationChannelBandwidth INTEGER, winlink1000HbsAirCarrierInformationAntennaGain INTEGER, winlink1000HbsAirCarrierInformationFeederLoss INTEGER, winlink1000HbsAirCarrierInformationMaxEirp INTEGER, winlink1000HbsAirCarrierInformationDfsState INTEGER, winlink1000HbsAirCarrierInformationAtpcEnable INTEGER, winlink1000HbsAirCarrierInformationDelayVsTputOpt INTEGER, winlink1000HbsAirCarrierInformationAvailResourcesDL INTEGER, winlink1000HbsAirCarrierInformationAvailResourcesUL INTEGER, winlink1000HbsAirCarrierInformationBEPercentage DisplayString } winlink1000HbsAirCarrierInformationIndex OBJECT-TYPE SYNTAX INTEGER { carrier1(1), carrier2(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Carrier index." ::= { winlink1000HbsAirCarrierInformationEntry 1 } winlink1000HbsAirCarrierInformationSubBandDescription OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Carrier Current Sub Band description." ::= { winlink1000HbsAirCarrierInformationEntry 2 } winlink1000HbsAirCarrierInformationState OBJECT-TYPE SYNTAX INTEGER { init (1), bitFailed (2), inactive (3), spectrumMeasurement (4), scanning (5), cac (6), transceiving (7), standBy (8), rawAlignment (9) } ACCESS read-only STATUS mandatory DESCRIPTION "Holds the state of the HBS." ::= { winlink1000HbsAirCarrierInformationEntry 3 } winlink1000HbsAirCarrierInformationFrequency OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Current Center Frequency. Measured in MHz if center frequency resolution value < 100, otherwise in KHz." ::= { winlink1000HbsAirCarrierInformationEntry 4 } winlink1000HbsAirCarrierInformationTxPower OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Current Transmit Power in dBm. This is a nominal value while the actual transmit power includes additional attenuation." ::= { winlink1000HbsAirCarrierInformationEntry 5 } winlink1000HbsAirCarrierInformationTotalTxPower OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Total Transmit Power in dBm. This is a nominal value While the actual transmit power includes additional attenuation." ::= { winlink1000HbsAirCarrierInformationEntry 6 } winlink1000HbsAirCarrierInformationChannelBandwidth OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Channel bandwidth in KHz. A change is effective after reset." ::= { winlink1000HbsAirCarrierInformationEntry 7 } winlink1000HbsAirCarrierInformationAntennaGain OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Current Antenna Gain in 0.1 dBi resolution. User defined value for external antenna. Legal range: MinAntennaGain port will reset)." ::= { winlink1000SNConfigDataPortEntry 14 } -- ########################################################### -- General -- ########################################################### winlink1000General OBJECT IDENTIFIER ::= { winlink1000 100 } winlink1000GeneralTrapDescription OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Trap's Description. Used for Trap parameters." ::= { winlink1000General 1 } winlink1000GeneralTrapSeverity OBJECT-TYPE SYNTAX INTEGER { event (1), normal (2), warning (4), minor (8), major (16), critical (32) } ACCESS read-only STATUS mandatory DESCRIPTION "Trap's Severity. Used for Trap parameters." ::= { winlink1000General 2 } winlink1000GeneralCookie OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Reserved for the Manager application provided with the product, used for saving user preferences affecting ODU operation." ::= { winlink1000General 3 } winlink1000GeneralEcChangesCounter OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This counter is initialized to 0 after a device reset and is incremented upon each element constant write operation via SNMP or Telnet." ::= { winlink1000General 4 } winlink1000GeneralTelnetSupport OBJECT-TYPE SYNTAX INTEGER { enable (1), disable (2), mandatoryDisabled(3), mandatoryEnabled(4) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable/Disable Telnet protocol. Mandatory Disabled - No option to enable the feature. Mandatory Enabled - No option to disable the feature." ::= { winlink1000General 5 } winlink1000GeneralWISupport OBJECT-TYPE SYNTAX INTEGER { mandatoryDisabled(1), mandatoryEnabled(2), disabled(3), enabled(4), securedOnlyEnabled(5), securedDisabled(6), securedAllModesEnabled(7), securedAllModesDisabled (8) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable/Disable Web Interface protocol. Mandatory Disabled - No option to enable the feature. Mandatory Enabled - No option to disable the feature. Secured Only Enabled - enable select HTTPS only. Secured Disabled - disable HTTPS. Secured all Enabled - enable select HTTP and HTTPS." ::= { winlink1000General 6 } winlink1000GeneralSNMPSupport OBJECT-TYPE SYNTAX INTEGER { v1Andv3(1), snmpv1Only(2), snmpv3Only(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Configuration of SNMP version " ::= { winlink1000General 7 } winlink1000GeneralSSHSupport OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2), unsupported(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable/Disable SSH protocols" ::= { winlink1000General 8 } winlink1000GeneralStrictHTTPS OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Strict HTTPS Mode" ::= { winlink1000General 9 } winlink1000GeneralIPForwarding OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable/Disable IP forwarding" ::= { winlink1000General 10 } -- ########################################################### -- Traps Section -- ########################################################### -- -- The ifIndex, Unit, Time_T and Alarm Id will be bind to the Trap only if -- winlink1000OduAgnGenAddTrapExt = 'yes'. -- trunkStateChanged TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000IduTdmIfIndex, winlink1000IduTdmLineStatus, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&MESG "$'1" DESCRIPTION " Indicates a change in the state of one of the TDM trunks. Raised by both sides of the link. Contains 3 parameters: 1 - Description: TDM Interface %n - %x 2 - %n: Is the trunk number 3 - %x: Is the alarm type and can be one of the following: Normal, AIS, LOS, Loopback " ::= 1 linkUp TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&CLEARS { 3 } --&MESG "$'1" DESCRIPTION " Indicates that the radio link is up. Contains a single parameter, which is its description: 1 - Description: Radio Link - Sync on channel %n GHz. %n Is the channel frequency in GHz. " ::= 2 linkDown TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { critical } --&MESG "$'1" DESCRIPTION " Indicates that the radio link is down. Contains a single parameter, which is its description: 1 - Description: Radio Link - Out of Sync. The reason is: %s. %s Is the reason. " ::= 3 detectIDU TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&CLEARS { 5 } --&MESG "$'1" DESCRIPTION " Indicates that the IDU was detected. Raised by both sides of the link. Contains a single parameter, which is its description: 1 - Description: IDU of Type %s was Detected. %s Is the type of the IDU. " ::= 4 disconnectIDU TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { major } --&MESG "$'1" DESCRIPTION " Indicates that the IDU was disconnected. Raised by both sides of the link. Contains a single parameter, which is its description: 1 - Description: IDU Disconnected. " ::= 5 mismatchIDU TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { major } --&MESG "$'1" DESCRIPTION " Indicates a mismatch between the IDUs. Raised by the master only. Contains a single parameter, which is its description: 1 - Description: IDUs Mismatch: One Side is %s and the Other is %s. %s Is the type of the IDU. " ::= 6 openedServices TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000IduSrvDesiredTrunks, winlink1000IduSrvActiveTrunks, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&MESG "$'1" DESCRIPTION " Indicates that services were opened. Raised by the master only. Contains 3 parameters: 1 - Description: %n2 out of %n1 Requested TDM Trunks have been Opened 2 - %n1: Is the requested number of TDM truncks 3 - %n2: Is the actual number of TDM trunks that were opened " ::= 7 closedServices TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&CLEARS { 100 } --&MESG "$'1" DESCRIPTION " Indicates that services were closed. Raised by the master only. Contains a single parameter, which is its description: 1 - Description: TDM Service has been closed. The reason is: %s. %s Is the reason. " ::= 8 incompatibleODUs TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { critical } --&MESG "$'1" DESCRIPTION " Indicates that the ODUs are incompatible. Contains a single parameter, which is its description: 1 - Description: Incompatible ODUs. " ::= 9 incompatibleIDUs TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { major } --&MESG "$'1" DESCRIPTION " Indicates that the IDUs are incompatible. Contains a single parameter, which is its description: 1 - Description: Incompatible IDUs. " ::= 10 incompatibleOduIdu TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { major } --&MESG "$'1" DESCRIPTION " Indicates that the ODU and IDU are incompatible. Contains a single parameter, which is its description: 1 - Description: The IDU could not be loaded. The reason is: %s. %s Is the incompatibility type. " ::= 11 probingChannel TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&MESG "$'1" DESCRIPTION " Indicates that the ODU is monitoring radar activity. Contains a single parameter, which is its description: 1 - Description: Monitoring for radar activity on channel %n GHz. %n is the channel frequency in GHz. " ::= 12 radarDetected TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&MESG "$'1" DESCRIPTION " Indicates that radar activity was detected. Contains a single parameter, which is its description: 1 - Description: Radar activity was detected in %s, on channel %n GHz. %s Is the site name. %n Is the channel frequency in GHz. " ::= 13 transmittingOnChannel TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&MESG "$'1" DESCRIPTION " Indicates that the ODU is transmitting on channel. Contains a single parameter, which is its description: 1 - Description: Transmitting on channel %n GHz. %n Is the channel frequency in GHz. " ::= 14 scanningChannels TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&MESG "$'1" DESCRIPTION " Indicates that the ODU is scanning channels. Contains a single parameter, which is its description: 1 - Description: Channel scanning in progress. " ::= 15 incompatiblePartner TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { critical } --&MESG "$'1" DESCRIPTION " Indicates that configuration problem was detected and that link installation is required in order to fix it. Contains a single parameter, which is its description: 1 - Description: Configuration problem detected. Link installation required. " ::= 16 timeClockSet TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&MESG "$'1" DESCRIPTION " Indicates that the ODU time clock was set. Contains a single parameter, which is its description: 1 - Description: The time was set to: %p. %p Is the date and time. " ::= 17 configurationChanged TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&MESG "$'1" DESCRIPTION " Indicates that the ODU recovered from an error, but there are configuration changes. Contains two parameters: 1 - Description: Configuration changed. Error code is: %n. 2 - %n number. " ::= 18 hssOpStateChangedToINU TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&CLEARS { 119 } --&MESG "$'1" DESCRIPTION " Indicates that the HSS operating state was changed to INU type. Contains a single parameter, which is its description: 1 - Description: HSS operating state was changed to: INU. " ::= 19 hssOpStateChangedToHSM TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&CLEARS { 119 } --&MESG "$'1" DESCRIPTION " Indicates that the HSS operating state was changed to HSM type. Contains a single parameter, which is its description: 1 - Description: HSS operating state was changed to: HSM. " ::= 20 hssOpStateChangedToHSC TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&CLEARS { 120 } --&MESG "$'1" DESCRIPTION " Indicates that the HSS operating state was changed to HSC type. Contains a single parameter, which is its description: 1 - Description: HSS operating state was changed to: HSC_DT/HSC_CT. " ::= 21 vlanModeActive TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&MESG "$'1" DESCRIPTION " Indicates to non-VLAN PC that after 2 minutes the system will support only VLAN tag on management interface. Contains a single parameter, which is its description: 1 - Description: VLAN Mode is active. Non-VLAN traffic will be blocked in 2 minutes. " ::= 22 spectrumAnalysis TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&MESG "$'1" DESCRIPTION " Indicates that the ODU is in Spectrum Analysis mode. Contains a single parameter, which is its description: 1 - Description: Spectrum analysis in progress. " ::= 23 hbsHsuDeregisteredOffline TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&MESG "$'1" DESCRIPTION " Indicates that a HSU was deregistered offline (out of link) " ::= 24 hbsHsuDeregisteredSuccessfully TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&MESG "$'1" DESCRIPTION " Indicates that a HSU was deregistered successfully " ::= 25 hbsHsuRegisteredSuccessfully TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&MESG "$'1" DESCRIPTION " Indicates that a HSU was registered successfully " ::= 26 hbsHsuRegistrationFailed TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&MESG "$'1" DESCRIPTION " Indicates that registration has failed " ::= 27 hbsHsuViolatedState TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&MESG "$'1" DESCRIPTION " Indicates (on the HBS side) that a HSU is violated state " ::= 28 hsuViolatedState TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { major } --&MESG "$'1" DESCRIPTION " Indicates (on the HSU side) that the HSU is violated state " ::= 29 hbsUnregisteredSynchronizedHsu TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&MESG "$'1" DESCRIPTION " Indicates an unregistered HSU has been synchronized. " ::= 30 hbsUnregisteredUnsynchronizedHsu TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&MESG "$'1" DESCRIPTION " Indicates an unregistered HSU lost synchronization. " ::= 31 cableQuality TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&MESG "$'1" DESCRIPTION " 1Gbps rate is not supported due to bad line quality. " ::= 32 httpAuthentication TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&MESG "$'1" DESCRIPTION " HTTP Authentication Failure. " ::= 33 telnetAuthentication TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&MESG "$'1" DESCRIPTION " Telnet Authentication Failure. " ::= 34 tdmServiceAlarm TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { major } --&MESG "$'1" DESCRIPTION " Indicates that TDM Service is in alarm state. Contains a single parameter, which is its description: 1 - Description: TDM Service - Alarm. " ::= 100 ethServiceClosed TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { major } --&MESG "$'1" DESCRIPTION " Indicates that Ethernet Service is closed. Contains a single parameter, which is its description: 1 - Description: Ethernet Service is closed. " ::= 101 ethServiceNotPermitted TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { major } --&MESG "$'1" DESCRIPTION " Indicates that Ethernet Service is not permitted. Contains a single parameter, which is its description: 1 - Description: A valid IDU could not be detected at %s. Please check your configuration. %s - Is the Local Site name or Remote Site name or both sides of the Link. " ::= 102 encryptionAlarm TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { major } --&MESG "$'1" DESCRIPTION " Indicates an encryption key mismatch. Contains a single parameter, which is its description: 1 - Description: Encryption Status - Failed. No Services are available. " ::= 103 changeLinkPasswordAlarm TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { major } --&MESG "$'1" DESCRIPTION " Indicates that a failure has occurred while attempting to change the Link Password. Contains a single parameter, which is its description: 1 - Description: Failed to change the Link Password at/on: %s. %s - Is the Local Site name or Remote Site name or both sides of the Link. " ::= 104 externalAlarmInPort1Alarm TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { major } --&MESG "$'1" DESCRIPTION " The trap is sent every time an alarm occurs in the External Alarm Input of port #1. Contains a single parameter, which is its description: 1 - Description: External Alarm 1 - - Alarm. " ::= 105 externalAlarmInPort2Alarm TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { major } --&MESG "$'1" DESCRIPTION " The trap is sent every time an alarm occurs in the External Alarm Input of port #2. Contains a single parameter, which is its description: 1 - Description: External Alarm 2 - - Alarm. " ::= 106 bitFailedAlarm TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { critical } --&MESG "$'1" DESCRIPTION " The trap is sent if there is no way to recover from the situation. Contains two parameters: 1 - Description: ODU power up built in test failed. Error code is: %n 2 - %n number " ::= 107 wrongConfigurationLoadedAlarm TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { major } --&MESG "$'1" DESCRIPTION " The trap is sent if there is a way to recover from the situation. Contains two parameters: 1 - Description: Wrong configuration loaded. Error code is: %n 2 - %n number " ::= 108 lanPort1DisconnectedAlarm TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { major } --&MESG "$'1" DESCRIPTION " Indicates the LAN port 1 status changed to disconnected. Contains a single parameter, which is its description: 1 - Description: LAN port 1 status changed to disconnected. " ::= 109 lanPort2DisconnectedAlarm TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { major } --&MESG "$'1" DESCRIPTION " Indicates the LAN port 2 status changed to disconnected. Contains a single parameter, which is its description: 1 - Description: LAN port 2 status changed to disconnected. " ::= 110 mngPortDisconnectedAlarm TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { major } --&MESG "$'1" DESCRIPTION " Indicates the LAN1 port status changed to disconnected. Contains a single parameter, which is its description: 1 - Description: LAN1 port status changed to disconnected. " ::= 111 externalAlarmInPort3Alarm TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { major } --&MESG "$'1" DESCRIPTION " The trap is sent every time an alarm occurs in the External Alarm Input of port #3. Contains a single parameter, which is its description: 1 - Description: External Alarm 3 - - Alarm. " ::= 112 externalAlarmInPort4Alarm TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { major } --&MESG "$'1" DESCRIPTION " The trap is sent every time an alarm occurs in the External Alarm Input of port #4. Contains a single parameter, which is its description: 1 - Description: External Alarm 4 - - Alarm. " ::= 113 swVersionsMismatchFullCompatibilityAlarm TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { warning } --&MESG "$'1" DESCRIPTION " The trap is sent if SW versions mismatch with full link functionality. Contains a single parameter, which is its description: 1 - Description: Software versions mismatch - full link functionality " ::= 114 swVersionsMismatchRestrictedCompatibilityAlarm TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { minor } --&MESG "$'1" DESCRIPTION " The trap is sent if SW versions mismatch with restricted link functionality. Contains a single parameter, which is its description: 1 - Description: Software versions mismatch - restricted link functionality " ::= 115 swVersionsMismatchSoftwareUpgradeRequired TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { major } --&MESG "$'1" DESCRIPTION " The trap is sent if SW versions mismatch and SW upgrade is required. Contains a single parameter, which is its description: 1 - Description: Software versions mismatch - Software upgrade required " ::= 116 swVersionsIncompatible TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { critical } --&MESG "$'1" DESCRIPTION " The trap is sent if SW versions are incompatible. Contains a single parameter, which is its description: 1 - Description: SW Versions incompatible " ::= 117 hssMultipleSourcesDetectedAlarm TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { major } --&MESG "$'1" DESCRIPTION " Indicates that multiple sync pulse sources were detected. Contains a single parameter, which is its description: 1 - Description: HSS multiple sync sources were detected. " ::= 118 hssSyncToProperSourceStoppedAlarm TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { major } --&MESG "$'1" DESCRIPTION " Indicates that synchronization to a proper sync pulse source was stopped. Contains a single parameter, which is its description: 1 - Description: HSS sync pulse - Down. The reason is: %s. %s - Is the reason for the sync down. " ::= 119 hssSyncPulseDetectedAlarm TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { major } --&MESG "$'1" DESCRIPTION " Indicates that HSS additional sync pulse was detected. Contains a single parameter, which is its description: 1 - Description: HSS additional sync pulse was detected. " ::= 120 tdmBackupAlarm TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { major } --&MESG "$'1" DESCRIPTION " Indicates that the TDM backup link was activated. Contains a single parameter, which is its description: 1 - Description: TDM backup alarm - backup link was activated. " ::= 121 linkLockUnauthorizedRemoteODU TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { major } --&MESG "$'1" DESCRIPTION " Indicates that the remote ODU is unauthorized. Contains a single parameter, which is its description: 1 - Description: Unauthorized remote ODU connection rejected. " ::= 122 linkLockUnauthorizedODU TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { major } --&MESG "$'1" DESCRIPTION " Indicates that the ODU is unauthorized. Contains a single parameter, which is its description: 1 - Description: Unauthorized ODU connection rejected. " ::= 123 hotStandbyAlarm TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { major } --&MESG "$'1" DESCRIPTION " Indicates that the hot standby secondary link was activated. Contains a single parameter, which is its description: 1 - Description: Secondary Link Is Active. " ::= 124 sfpInsertion TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&MESG "$'1" DESCRIPTION " Indicates that a device was inserted to SFP Port " ::= 126 sfpPort1DisconnectedAlarm TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { major } --&MESG "$'1" DESCRIPTION " Indicates the SFP port 1 status changed to disconnected. Contains a single parameter which is its description: 1 - Description: SFP port 1 status changed to disconnected. " ::= 127 ringRplStateActiveAlarm TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { major } --&MESG "$'1" DESCRIPTION " RPL state changed to Active. " ::= 128 desiredRatioCanNotBeAppliedAlarm TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { minor } --&MESG "$'1" DESCRIPTION " Indicates Desired UL/DL RAtio Can Not Be Applied. " ::= 129 cbwMismatch TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { major } --&MESG "$'1" DESCRIPTION " Indicates that a Channel Bandwidth mismatch was detected. Contains two parameters: 1 - Description: Channel Bandwidth Mismatch: one side is %n0 MHz and the other is %n1 MHz. %n0 is the local Channel Bandwidth value in MHz. %n1 is the remote Channel Bandwidth value in MHz." ::= 130 gpsNotSynchronized TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { major } --&MESG "$'1" DESCRIPTION " Indicates that the GPS is not synchronized with satellites. Pulses are self generated. " ::= 131 pdTooHighDueCbwLimitations TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { major } --&MESG "$'1" DESCRIPTION " Indicates that link cannot be established because link range is too large for channel bandwidth. " ::= 132 hbsEncryptionAlarm TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { major } --&MESG "$'1" DESCRIPTION " Indicates an encryption key mismatch. Contains a single parameter, which is its description, including the HSU's name " ::= 133 hbsEhServiceClosedToHsu TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { major } --&MESG "$'1" DESCRIPTION " Indicates an encryption key mismatch. Contains a single parameter, which is its description, including the HSU's name " ::= 134 hbsUnsynchronizedHsuAlarm TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { critical } --&MESG "$'1" DESCRIPTION " Indicates a registered HSU lost synchronization. " ::= 135 hbsInactiveHbsAlarm TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { major } --&MESG "$'1" DESCRIPTION " Indicates HBS is InActive. " ::= 136 incompatibleHsu TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { critical } --&MESG "$'1" DESCRIPTION " Indicates that the HSU is not compatible to HBS. Contains a single parameter, which is its description: 1 - Description: Incompatible HSU. " ::= 137 hsuUnsupportedBeacon TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { warning } --&MESG "$'1" DESCRIPTION " Indicates an unsupported beacon has arrived at HSU " ::= 138 lanPortDisconnectedAlarm TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { major } --&MESG "$'1" DESCRIPTION " Indicates the LAN port status changed to disconnected. Contains a single parameter, which is its description: 1 - Description: LAN port status changed to disconnected. " ::= 139 poePortDisconnectedAlarm TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { major } --&MESG "$'1" DESCRIPTION " Indicates the LAN2 port status changed to disconnected. Contains a single parameter, which is its description: 1 - Description: LAN2 port status changed to disconnected. " ::= 140 poePowerConsumptionAlarm TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { major } --&MESG "$'1" DESCRIPTION " Indicates the POE Power Consumption is above allowed maximum. Contains a single parameter, which is its description: 1 - Description: POE consumption above allowed maximum. port closed. " ::= 141 hobupFaultyStateAlarm TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { major } --&MESG "$'1" DESCRIPTION " This Alarm will indicate that the Hot Backup module is in faulty state. 1 - Description: Hot Backup fault detected: %s unit. %s - Primary Or Secondary Unit " ::= 149 gpsOverCurrentAlarm TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { major } --&MESG "$'1" DESCRIPTION " Indicates the GPS Antenna current consumption is above allowed maximum. Contains a single parameter, which is its description: 1 - Description: GPS Antenna current consumption above allowed maximum. GPS closed. " ::= 150 gpsCommunicationFailiureAlarm TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { major } --&MESG "$'1" DESCRIPTION " Indicates the GPS data isn't received. Contains a single parameter, which is its description: 1 - Description: GPS Communication failiure. " ::= 151 temperatureThresholdAlarm TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { major } --&MESG "$'1" DESCRIPTION " Indicates the board temperature is above allowed maximum. Contains a single parameter, which is its description: 1 - Description: Indicates the board temperature exceed the threshold. " ::= 152 localRouterDiscoveryStatus TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { major } --&MESG "$'1" DESCRIPTION " This Alarm will indicate that we have no connection with local train router. 1 - Description: MacLearningUpdate detected disconnection with local train router %s %s - local train IP " ::= 153 trackRouterDiscoveryStatus TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { major } --&MESG "$'1" DESCRIPTION " This Alarm will indicate that we have no connection with Track side router. 1 - Description: MacLearningUpdate detected disconnection with Track side router %s %s - Default gateway IP " ::= 154 lastUserSnmpAccessOverHourAgo TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&MESG "$'1" DESCRIPTION " This trap will indicate that the last access of the accessing user was more than an hour ago. 1 - Description: User %s performed SNMP access after more than an hour. %s - user name " ::= 155 btsTargetUnreachable TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { major } --&MESG "$'1" DESCRIPTION " This Alarm will indicate that we have no connection with Bts desired target. 1 - Description: TNC detected disconnection with the BTS target %s %s - Default gateway IP " ::= 156 hbsLinkQualityDegredationDlAlarm TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { major } --&MESG "$'1" DESCRIPTION " Indicates a link downlink quality degredation. " ::= 158 hbsLinkQualityDegredationUlAlarm TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { major } --&MESG "$'1" DESCRIPTION " Indicates a link uplink quality degredation. " ::= 159 tdmServiceClear TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&CLEARS { 100 } --&MESG "$'1" DESCRIPTION " Indicates that TDM Service fault is cleared. Contains a single parameter, which is its description: 1 - Description: TDM Service - Normal. " ::= 200 ethServiceOpened TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&CLEARS { 101 } --&MESG "$'1" DESCRIPTION " Indicates that Ethernet Service has been opened. Contains a single parameter, which is its description: 1 - Description: Ethernet Service has been opened. " ::= 201 encryptionClear TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&CLEARS { 103 } --&MESG "$'1" DESCRIPTION " Indicates that encryption is OK. Contains a single parameter, which is its description: 1 - Description: Encryption Status - Normal. " ::= 203 changeLinkPasswordClear TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&CLEARS { 104 } --&MESG "$'1" DESCRIPTION " Indicates that the Link Password was changed successfully. Contains a single parameter, which is its description: 1 - Description: Link Password has been changed at/on: %s. %s - Is the Local Site name or Remote Site name or both sides of the Link. " ::= 204 externalAlarmInPort1Clear TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&CLEARS { 105 } --&MESG "$'1" DESCRIPTION " This Trap is sent every time an External Alarm Input fault of port # 1 is cleared. Contains a single parameter, which is its description: 1 - Description: External Alarm 1 - - Alarm Cleared. " ::= 205 externalAlarmInPort2Clear TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&CLEARS { 106 } --&MESG "$'1" DESCRIPTION " This Trap is sent every time an External Alarm Input fault of port # 2 is cleared. Contains a single parameter, which is its description: 1 - Description: External Alarm 2 - - Alarm Cleared. " ::= 206 lanPort1Clear TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&CLEARS { 109 } --&MESG "$'1" DESCRIPTION " Indicates the LAN port 1 status changed to connected. Contains two parameters: 1 - Description: LAN port 1 status changed to connected - %s 2 - %s Is the Eth. mode (speed & duplex) " ::= 209 lanPort2Clear TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&CLEARS { 110 } --&MESG "$'1" DESCRIPTION " Indicates the LAN port 2 status changed to connected. Contains two parameters: 1 - Description: LAN port 2 status changed to connected - %s. 2 - %s Is the Eth. mode (speed & duplex). " ::= 210 mngPortClear TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&CLEARS { 111 } --&MESG "$'1" DESCRIPTION " Indicates the LAN1 port status changed to connected. Contains two parameters: 1 - Description: LAN1 port status changed to connected - %s 2 - %s Is the Eth. mode (speed & duplex) " ::= 211 externalAlarmInPort3Clear TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&CLEARS { 112 } --&MESG "$'1" DESCRIPTION " This Trap is sent every time an External Alarm Input fault of port # 3 is cleared. Contains a single parameter, which is its description: 1 - Description: External Alarm 3 - - Alarm Cleared. " ::= 212 externalAlarmInPort4Clear TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&CLEARS { 113 } --&MESG "$'1" DESCRIPTION " This Trap is sent every time an External Alarm Input fault of port # 4 is cleared. Contains a single parameter, which is its description: 1 - Description: External Alarm 4 - - Alarm Cleared. " ::= 213 swVersionsMatchFullCompatibilityClear TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&CLEARS { 114 } --&MESG "$'1" DESCRIPTION " The trap is sent if SW versions match. Contains a single parameter, which is its description: 1 - Description: Software Versions compatible " ::= 214 swVersionsMatchRestrictedCompatibilityClear TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&CLEARS { 115 } --&MESG "$'1" DESCRIPTION " The trap is sent if SW versions match and link functionality is not restricted. Contains a single parameter, which is its description: 1 - Description: Software Versions compatible " ::= 215 swVersionsMatchSoftwareUpgradeRequiredClear TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&CLEARS { 116 } --&MESG "$'1" DESCRIPTION " The trap is sent if SW versions match and SW upgrade is successful. Contains a single parameter, which is its description: 1 - Description: Software Versions compatible " ::= 216 swVersionsCompatibleClear TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&CLEARS { 117 } --&MESG "$'1" DESCRIPTION " The trap is sent if SW versions compatible Contains a single parameter, which is its description: 1 - Description: Software Versions compatible " ::= 217 hssMultipleSourcesDisappearedClear TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&CLEARS { 118 } --&MESG "$'1" DESCRIPTION " Indicates that multiple sync pulse sources disappeared. Contains a single parameter, which is its description: 1 - Description: HSS multiple sync pulse sources disappeared. " ::= 218 hssSyncToProperSourceAchievedClear TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&CLEARS { 119 } --&MESG "$'1" DESCRIPTION " Indicates that synchronization to a proper Sync source was achieved. Contains a single parameter, which is its description: 1 - Description: HSS sync pulse - Up. " ::= 219 hssSyncPulseDisappearedClear TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&CLEARS { 120 } --&MESG "$'1" DESCRIPTION " Indicates that HSS additional sync pulse disappeared. Contains a single parameter, which is its description: 1 - Description: HSS additional sync pulse was disappeared. " ::= 220 tdmBackupClear TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&CLEARS { 121 } --&MESG "$'1" DESCRIPTION " Indicates that the TDM main link was activated. Contains a single parameter, which is its description: 1 - Description: TDM main link was activated. " ::= 221 linkLockAuthorizedRemoteODU TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&CLEARS { 122 } --&MESG "$'1" DESCRIPTION " Indicates that the remote ODU is authorized. Contains a single parameter, which is its description: 1 - Description: Authorized remote ODU connection accepted. " ::= 222 linkLockAuthorizedODU TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&CLEARS { 123 } --&MESG "$'1" DESCRIPTION " Indicates that the ODU is authorized. Contains a single parameter, which is its description: 1 - Description: Authorized ODU connection permitted. " ::= 223 linkAuthenticationDisabled TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&CLEARS { 122 } --&MESG "$'1" DESCRIPTION " Indicates that the Link Lock is disabled. Contains a single parameter, which is its description: 1 - Description: Link Authentication has been disabled. " ::= 224 hotStandbyClear TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&CLEARS { 124 } --&MESG "$'1" DESCRIPTION " Indicates that the Primary Link Was Activated. Contains a single parameter, which is its description: 1 - Description: Primary Link Is Active. " ::= 225 sfpExtraction TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&MESG "$'1" DESCRIPTION " Indicates that a device was extracted from SFP Port " ::= 226 sfpPort1Clear TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&CLEARS { 127 } --&MESG "$'1" DESCRIPTION " Indicates the SFP port 1 status changed to connected. Contains two parameters: 1 - Description: SFP port 1 status changed to connected - %s 2 - %s Is the Eth. mode (speed & duplex) " ::= 227 compatibleIdus TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&CLEARS { 10 } --&MESG "$'1" DESCRIPTION " Indicates that the ODU has identified compatible Idus on both sides of the link. " ::= 228 desiredRatioCanNotBeAppliedClear TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&CLEARS { 129 } --&MESG "$'1" DESCRIPTION " Indicates Current UL/DL Ratio Is Equal To Desired Ratio. " ::= 229 cbwMatch TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&CLEARS { 130 } --&MESG "$'1" DESCRIPTION " Indicates that a Channel Bandwidth match was detected. Contains a single parameter, which is its description: 1 - Channel Bandwidth value in MHz. " ::= 230 switchCbwAndChannel TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&MESG "$'1" DESCRIPTION " Indicates that the system is switching Channel Bandwidth and channel frequency. Contains two parameters: 1 - Switching to Channel Bandwidth %n0 MHz. 2 - Switching to Channel Frequency %n1 GHz. " ::= 231 ringRplStateIdle TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&CLEARS { 128 } --&MESG "$'1" DESCRIPTION " RPL state changed to Idle. " ::= 232 ringEthServiceStatus TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&MESG "$'1" DESCRIPTION " Indicates Ethernet service's state - blocked \ unblocked. Contains a single parameter: 1 - Description: Ethernet's state (blocked \ unblocked) " ::= 233 ringFirstRpmReceived TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&MESG "$'1" DESCRIPTION " Ring application: in non-RPL link indicates first from a specific RPL was received. Contains a single parameter: 1 - Description: RPM's VLAN ID " ::= 234 ringEthernetSrviceUnblockedTO TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&MESG "$'1" DESCRIPTION " Ring application: in non-RPL link Ethernet service is unblocked due to RPM timeout. " ::= 235 gpsSynchronized TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&CLEARS { 131 } --&MESG "$'1" DESCRIPTION " Indicates that the GPS is synchronized with satellites. " ::= 236 hbsEncryptionClear TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&CLEARS { 133 } --&MESG "$'1" DESCRIPTION " Indicates that encryption is OK. Contains a single parameter, which is its description, including the HSU's name " ::= 237 hbsEhServiceOpenedToHsu TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&CLEARS { 134 } --&MESG "$'1" DESCRIPTION " Indicates that encryption is OK. Contains a single parameter, which is its description, including the HSU's name " ::= 238 hbsSynchronizedHsuAlarm TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&CLEARS { 135 } --&MESG "$'1" DESCRIPTION " Indicates a registered HSU is synchronized. " ::= 239 hbsActiveHbs TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&CLEARS { 136 } --&MESG "$'1" DESCRIPTION " Indicates when HBS has been activated. " ::= 240 switchCBW TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&MESG "$'1" DESCRIPTION " Switching Channel Bandwidth. " ::= 241 changeRatio TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&MESG "$'1" DESCRIPTION " HBS Tx ratio has changed. " ::= 242 lanPortClear TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&CLEARS { 139 } --&MESG "$'1" DESCRIPTION " Indicates the LAN port status changed to connected. Contains two parameters: 1 - Description: LAN port status changed to connected - %s 2 - %s Is the Eth. mode (speed & duplex) " ::= 243 poePortClear TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&CLEARS { 140 } --&MESG "$'1" DESCRIPTION " Indicates the LAN2 port status changed to connected. Contains two parameters: 1 - Description: LAN2 port status changed to connected - %s 2 - %s Is the Eth. mode (speed & duplex) " ::= 244 poePowerConsumptionClear TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&CLEARS { 141 } --&MESG "$'1" DESCRIPTION " Indicates the POE power consumption is valid. Contains two parameters: 1 - Description: POE consumption within limits. port is opened. 2 - %s Is the Eth. mode (speed & duplex) " ::= 245 incompatibleHbsHsu TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&MESG "$'1" DESCRIPTION " Incompatible HBS/HSU software versions - no service. " ::= 246 mobilityLinkOff TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&MESG "$'1" DESCRIPTION " Mobility - Link cannot be established due to: 1 - The HBS does not support Mobility 2 - Lack of resources in the HBS for HSU level " ::= 247 enterLocalConnection TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&MESG "$'1" DESCRIPTION " Entering Local Connection (Broadcast) Mode. " ::= 248 hobupActiveStateFaultyClear TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&CLEARS { 149 } --&MESG "$'1" DESCRIPTION " this clear alarm will indicate that the Hot Backup unit is in active state. Contains a single parameter, which is its description: 1 - Description: Hot Backup %s unit activated. %s - Primary Or Secondary Unit " ::= 249 hobupStandbyState TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&MESG "$'1" DESCRIPTION " This info fault will indicate that the Hot backup module has entered standby/peer_detection state Contains a single parameter, which is its description: 1 - Description: Hot Backup in Standby state: %s unit. %s - Primary Or Secondary Unit " ::= 250 gpsOverCurrentClear TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&CLEARS { 150 } --&MESG "$'1" DESCRIPTION " Indicates the GPS Antenna current consumption is valid. " ::= 251 temperatureThresholdClear TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&CLEARS { 152 } --&MESG "$'1" DESCRIPTION " Indicates the board temperature is valid. " ::= 252 localRouterDiscoverySucceed TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&CLEARS { 153 } --&MESG "$'1" DESCRIPTION " Indicates that we succeeded to discover train router in ip %s MAC address %s %s Train IP %s Train MAC Address " ::= 253 trackRouterDiscoverySucceed TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&CLEARS { 154 } --&MESG "$'1" DESCRIPTION " Indicates that we succeeded to discover track router in ip %s MAC address %s %s Train IP %s Train MAC Address " ::= 254 qosVersion2StrictMismatch TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&MESG "$'1" DESCRIPTION " CPE doesn't support strict QOS configuration. " ::= 255 qosVersion2TtlMismatch TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&MESG "$'1" DESCRIPTION " CPE doesn't support TTL configuration. " ::= 256 btsTargetIsReachable TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&CLEARS { 156 } --&MESG "$'1" DESCRIPTION " Indicated the we succeeded to establish connection with the Bts desired target (%s) %s Target IP " ::= 257 tcNotSupportedByHSU TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&MESG "$'1" DESCRIPTION " CPE doesn't support TC functionality. " ::= 258 syncEPortHOStateChange TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&MESG "$'1" DESCRIPTION " Enter/leave HO state of SyncE port. " ::= 259 syncEPortFailureStateChange TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&MESG "$'1" DESCRIPTION " Enter/leave Failure state of SyncE port. " ::= 260 btsCpeUpdateServiceFailed TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&MESG "$'1" DESCRIPTION " Update service Failed " ::= 261 btsCpeUpdateServiceSucceed TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&MESG "$'1" DESCRIPTION " Update service Succeed " ::= 262 radiusServerNoREsponse TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { major } --&MESG "$'1" DESCRIPTION " No response from radius server " ::= 263 noRadiusServerRespond TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { major } --&MESG "$'1" DESCRIPTION " No response from radius server " ::= 264 radiusServerRespondedSuccessfully TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&CLEARS { 264 } --&MESG "$'1" DESCRIPTION " indicates that Radius server responded successfully. " ::= 265 bsaAlignmentStarted TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&MESG "$'1" DESCRIPTION " Indicate the beginning of Alignment Process " ::= 266 bsaAlignmentFinished TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&MESG "$'1" DESCRIPTION " Indicate the completion of Alignment Process " ::= 267 bsaAlignmentTriggered TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&MESG "$'1" DESCRIPTION " Indicate the triggering of Alignment Process due to exceeding thresholds " ::= 268 hbsLinkQualityImprovedDlClear TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&CLEARS { 158 } --&MESG "$'1" DESCRIPTION " Indicates that downlink link quality improved. Contains a single parameter, which is its description, including the HSU's name " ::= 269 hbsLinkQualityImprovedUlClear TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&CLEARS { 159 } --&MESG "$'1" DESCRIPTION " Indicates that uplink link quality improved. Contains a single parameter, which is its description, including the HSU's name " ::= 270 hsuResourceTypeMismatch TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&MESG "$'1" DESCRIPTION " Indicate mismatch between HSU type and resource allocation " ::= 271 externalAntennaAttached TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&MESG "$'1" DESCRIPTION " Indicates that the External Antenna is attached " ::= 272 externalAntennaDetached TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&MESG "$'1" DESCRIPTION " Indicates that the External Antenna is detached " ::= 273 wifiEnabled TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&MESG "$'1" DESCRIPTION " Indicates that the Wifi is enabled " ::= 274 wifiDisabled TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&MESG "$'1" DESCRIPTION " Indicates that the wifi is disabled " ::= 275 wifiUserConnected TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&MESG "$'1" DESCRIPTION " Indicates that the Wifi is connected by some user " ::= 276 authenticationMgrUserAutheticationDoneLocally TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&MESG "$'1" DESCRIPTION " Authentication Mgr User Authentication is done locally and not against radius server. " ::= 277 authenticationMgrRadiusrequestResult TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&MESG "$'1" DESCRIPTION " Authentication Mgr : Request result returned from Radius Authentication Server . " ::= 278 authenticationMgrRemovedEntryFromTable TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&MESG "$'1" DESCRIPTION " Authentication Mgr : Removed User Or Ip from table. " ::= 279 hsuAuthenticationErrorState TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&MESG "$'1" DESCRIPTION " Indicates (on the HSU side) that the HSU is in authentication error state " ::= 280 hbsHsuAuthenticationErrorState TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&MESG "$'1" DESCRIPTION " Indicates (on the HSU side) that the HSU is in authentication error state " ::= 281 hsuExitingViolatedState TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&CLEARS { 29 } --&MESG "$'1" DESCRIPTION " Indicates (on the HSU side) that the HSU exited from violated state " ::= 282 batteryCapacityBelowThreshold TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { major } --&MESG "$'1" DESCRIPTION " Indicates that battery capacity is below the threshold. " ::= 283 batteryTemperatureOutOfRange TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { major } --&MESG "$'1" DESCRIPTION " Indicates that battery temperature is out of range. " ::= 284 batteryVoltageOutOfRange TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { major } --&MESG "$'1" DESCRIPTION " Indicates that battery voltage is out of range. " ::= 285 batteryCurrentOutOfRange TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { major } --&MESG "$'1" DESCRIPTION " Indicates that battery current is out of range. " ::= 286 portPowerFailure TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { major } --&MESG "$'1" DESCRIPTION " Indicates port power failure. " ::= 287 portPowerOn TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&MESG "$'1" DESCRIPTION " Indicates port power is on. " ::= 288 portPowerOff TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { major } --&MESG "$'1" DESCRIPTION " Indicates port power is off. " ::= 289 portPingLossToDevice TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { major } --&MESG "$'1" DESCRIPTION " Indicates port keepalive lost ping to configured device ip. " ::= 290 ambientTemperatureNormal TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { major } --&MESG "$'1" DESCRIPTION " Indicates that the ambient temprature is normal. " ::= 291 ambientTemperatureOutOfRange TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { major } --&MESG "$'1" DESCRIPTION " Indicates that the ambient temprature is out of range. " ::= 292 mainPowerSupplyFailure TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { critical } --&MESG "$'1" DESCRIPTION " Indicates of main power supply failure " ::= 293 mainPowerSupplyResume TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { critical } --&MESG "$'1" DESCRIPTION " Indicates that main power supply resume. " ::= 294 inputAlarm1Off TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { major } --&MESG "$'1" DESCRIPTION " Indicates Input Alarm #1 changed to off. " ::= 295 inputAlarm1On TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { major } --&MESG "$'1" DESCRIPTION " Indicates Input Alarm #1 changed to on. " ::= 296 inputAlarm2Off TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { major } --&MESG "$'1" DESCRIPTION " Indicates Input Alarm #2 changed to off. " ::= 297 inputAlarm2On TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { major } --&MESG "$'1" DESCRIPTION " Indicates Input Alarm #2 changed to on. " ::= 298 tamperCoverClosed TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { major } --&MESG "$'1" DESCRIPTION " Indicates that the smartnode cover was closed. " ::= 299 tamperCoverOpened TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { major } --&MESG "$'1" DESCRIPTION " Indicates that the smartnode cover was opened. " ::= 300 port8021xEnabledChangedState TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&MESG "$'1" DESCRIPTION " Indicates that 802.1x Enabled Port has changed its state for supplicant " ::= 301 ethMissionServerEthernetPortRestarted TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&MESG "$'1" DESCRIPTION " EthMissionServer : Ethernet port was restarted " ::= 302 virtualIPMismatch TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&MESG "$'1" DESCRIPTION " Signal that the peer Mus have different Virtual IP " ::= 303 sshAuthenticationFailure TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&MESG "$'1" DESCRIPTION " Signal that SSH Authentication failure " ::= 304 sshAuthenticationSuccess TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&MESG "$'1" DESCRIPTION " Signal that SSH Authentication success " ::= 305 hssSwHscPartiallySupported TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { minor } --&MESG "$'1" DESCRIPTION " incompatible HSS Configuration - please upgrade HSM " ::= 306 hssFwUpgradeFailure TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { critical } --&MESG "$'1" DESCRIPTION " Failed to update GPS firmware - please reboot device " ::= 307 tvwsUriChangedByTvws TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&MESG "$'1" DESCRIPTION " A trap indicating TVWSDB URI change, indicated in a response during INIT message. 1 - Description: TVWSDB URI change " ::= 312 tvwsPawsErrorAlarm TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { critical } --&MESG "$'1" DESCRIPTION " A trap indicating an error in PAWS message 1 - Description: error in PAWS message " ::= 313 tvwsdbConnectivityErrorAlarm TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { critical } --&MESG "$'1" DESCRIPTION " A trap indicating a connectivity error with the TVWSDB. 1 - Description: connectivity error with the TVWSDB " ::= 311 tvwsdbEtsiWeblistingConnectivityError TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&MESG "$'1" DESCRIPTION " A trap indicating a connectivity error with ETSI TVWSDB weblisting. 1 - Description: connectivity error with ETSI TVWSDB weblisting. " ::= 315 tvwsdbConnectedClear TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&CLEARS { 313 } --&MESG "$'1" DESCRIPTION " A trap indicating successful connectivity with the TVWSDB. 1 - Description: successful connectivity with the TVWSDB. " ::= 314 tvwsMopClear TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&CLEARS { 312 } --&MESG "$'1" DESCRIPTION " A trap indicating the selected Master operational parameters following channel selection algorithm. 1 - Description: selected Master operational parameters following channel selection algorithm. " ::= 316 tvwsNoAvailableChannelForHbsAlarm TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { critical } --&MESG "$'1" DESCRIPTION " A trap indicating that the channel selection algorithm found no available channel for the HBS 1 - Description: channel selection algorithm found no available channel for the HBS " ::= 317 tvwsGop TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&MESG "$'1" DESCRIPTION " A trap indicating the Generic Slave operational parameters following channel selection algorithm 1 - Description: Generic Slave operational parameters following channel selection algorithm " ::= 318 tvwsSopClear TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&CLEARS { 322 } --&MESG "$'1" DESCRIPTION " A trap indicating the selected Slave operational parameters following carrier selection algorithm for HSU 1 - Description: selected Slave operational parameters following carrier selection algorithm for HSU " ::= 319 tvwsSpectrumUseRespError TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&MESG "$'1" DESCRIPTION " A trap indicating error in SPECTRUM_USE_RESP message 1 - Description: error in SPECTRUM_USE_RESP message " ::= 320 tvwsSpectrumUseRespCriticalErrorAlarm TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { critical } --&MESG "$'1" DESCRIPTION " A trap indicating error in SPECTRUM_USE_RESP message 1 - Description: error in SPECTRUM_USE_RESP message " ::= 321 tvwsNoCarrierAvailableForRegisteredHsuAlarm TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { major } --&MESG "$'1" DESCRIPTION " A trap indicating that the carrier selection algorithm found no available channel for a registered HSU. 1 - Description: carrier selection algorithm found no available channel for a registered HSU. " ::= 322 tvwsNoCarrierAvailableForUnregisteredHsu TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&MESG "$'1" DESCRIPTION " A trap indicating that the carrier selection algorithm found no available channel for an unregistered HSU. 1 - Description: carrier selection algorithm found no available channel for an unregistered HSU. " ::= 323 gpsNotSynchronizedAlarm TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { major } --&MESG "$'1" DESCRIPTION " A trap indicating that the GPS is not synchronized 1 - Description: GPS is not synchronized " ::= 324 gpsSynchronizedClear TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { major } --&CLEARS { 324 } --&MESG "$'1" DESCRIPTION " A trap indicating that the GPS is synchronized 1 - Description: GPS is synchronized " ::= 325 gpsLocationChange TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { major } --&MESG "$'1" DESCRIPTION " A trap indicating that the GPS coordinates changed by a distance > max location change defined by the TVWSDB 1 - Description: GPS coordinates changed by a distance > max location change defined by the TVWSDB " ::= 326 tvwsHardwareFailure TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { major } --&MESG "$'1" DESCRIPTION " A trap indicating that the TVWS hardware encountered critical failure " ::= 327 changeStateOdu TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&MESG "$'1" DESCRIPTION " Indicated on state change of the unit due to redundancy feature. " ::= 328 radiusAuthenErrClear TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&CLEARS { 330 } --&MESG "$'1" DESCRIPTION " Radius Authentication Error clear " ::= 329 radiusCommunicationErr TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { major } --&MESG "$'1" DESCRIPTION " Radius Communication Error - Server Authentication Failed " ::= 330 duplicateMacDetected TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { major } --&MESG "$'1" DESCRIPTION " Indicates that duplicated MAC is detected and corresponding SU is blocked. " ::= 331 radiusAuthorizationFailure TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&MESG "$'1" DESCRIPTION " Authorization reject from Radius Server. " ::= 332 radiusAuthorizationSuccess TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&MESG "$'1" DESCRIPTION " Authorization Accept from Radius Server. " ::= 333 duplicateMacCleared TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&CLEARS { 331 } --&MESG "$'1" DESCRIPTION " Indicates that duplicated MAC is cleared for specific SU and corresponding SU is unblocked. " ::= 334 changeStateMuteMU TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&MESG "$'1" DESCRIPTION " Indicates MU state change in case of more than 2 MUs per train, MU can be muted (disable TX) or unmuted. " ::= 335 illegalNumOfTrainIDs TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&MESG "$'1" DESCRIPTION " Indicates Illegal Amount Of Train IDs in case of 2 Trains Merge feature. " ::= 336 pawsDBNotActive TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&MESG "$'1" DESCRIPTION " selected paws DB is not active alarm " ::= 337 pawsDBNameMismatch TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&MESG "$'1" DESCRIPTION " selected paws DB name is not found in the weblist alarm " ::= 338 pawsDBNotActiveCleared TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&CLEARS { 337 } --&MESG "$'1" DESCRIPTION " selected paws DB is not active alarm cleared " ::= 339 pawsDBNameMismatchCleared TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&CLEARS { 338 } --&MESG "$'1" DESCRIPTION " selected paws DB name is not found in the weblist alarm Cleared " ::= 340 linkPasswordChange TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&MESG "$'1" DESCRIPTION " Link password changed " ::= 341 hbsDisconnectionMuIbhoAlarm TRAP-TYPE ENTERPRISE winlink1000 VARIABLES { winlink1000GeneralTrapDescription, winlink1000OduAgnCurrAlarmSeverity, winlink1000OduAgnCurrAlarmIfIndex, winlink1000OduAgnCurrAlarmUnit, winlink1000OduAgnCurrAlarmTimeT, winlink1000OduAgnCurrAlarmId } --&ACTIONS { normal } --&MESG "$'1" DESCRIPTION " Indicates a registered MU disconnection due to Ibho . " ::= 342 -- ########################################################### -- Products Section -- ########################################################### radwinProducts OBJECT IDENTIFIER ::= { radwin 20 } winlink1000Family OBJECT IDENTIFIER ::= { radwinProducts 2 } radwin2000Family OBJECT IDENTIFIER ::= { radwinProducts 3 } gpsSynchronizerFamily OBJECT IDENTIFIER ::= { radwinProducts 4 } radwin5000HBSFamily OBJECT IDENTIFIER ::= { radwinProducts 5 } radwin5000HSUFamily OBJECT IDENTIFIER ::= { radwinProducts 6 } radwin6000Family OBJECT IDENTIFIER ::= { radwinProducts 10 } radwinWiFiAPFamily OBJECT IDENTIFIER ::= { radwinProducts 20 } radwinSmartNodeFamily OBJECT IDENTIFIER ::= { radwinProducts 30 } radwinNetworkingFamiliy OBJECT IDENTIFIER ::= { radwinProducts 40 } -- -- the following identifiers are assigned to ODU Products -- odu OBJECT IDENTIFIER ::= { winlink1000Family 1 } oduIntegratedAntenna OBJECT IDENTIFIER ::= { odu 1 } oduExternalAntenna OBJECT IDENTIFIER ::= { odu 2 } -- -- Suffix 3,4,5,6,7,8,9,10,11,12,13,14,15,16 in the products section -- are reserved for backward compatibility. -- odu2000 OBJECT IDENTIFIER ::= { radwin2000Family 1 } odu2KIntegratedAntenna OBJECT IDENTIFIER ::= { odu2000 1 } odu2KExternalAntenna OBJECT IDENTIFIER ::= { odu2000 2 } oduGSU OBJECT IDENTIFIER ::= { gpsSynchronizerFamily 1 } oduGSUExternalAntenna OBJECT IDENTIFIER ::= { oduGSU 2 } hssSyncUnits OBJECT IDENTIFIER ::= { gpsSynchronizerFamily 2 } hssISU OBJECT IDENTIFIER ::= { hssSyncUnits 1 } hssGSU OBJECT IDENTIFIER ::= { hssSyncUnits 2 } oduHBS OBJECT IDENTIFIER ::= { radwin5000HBSFamily 1 } oduHBSIntegratedAntenna OBJECT IDENTIFIER ::= { oduHBS 1 } oduHBSExternalAntenna OBJECT IDENTIFIER ::= { oduHBS 2 } oduHBSEmbeddedAntenna OBJECT IDENTIFIER ::= { oduHBS 3 } oduHSU OBJECT IDENTIFIER ::= { radwin5000HSUFamily 1 } oduHSUIntegratedAntenna OBJECT IDENTIFIER ::= { oduHSU 1 } oduHSUExternalAntenna OBJECT IDENTIFIER ::= { oduHSU 2 } oduHSUEmbeddedAntenna OBJECT IDENTIFIER ::= { oduHSU 3 } odu6000 OBJECT IDENTIFIER ::= { radwin6000Family 1 } odu6K OBJECT IDENTIFIER ::= { odu6000 1 } gateway6000 OBJECT IDENTIFIER ::= { radwin6000Family 2 } gateway6K OBJECT IDENTIFIER ::= { gateway6000 1 } odu600 OBJECT IDENTIFIER ::= { radwinWiFiAPFamily 1 } oduWiFiAP OBJECT IDENTIFIER ::= { odu600 1 } smartNode OBJECT IDENTIFIER ::= { radwinSmartNodeFamily 1 } iduS OBJECT IDENTIFIER ::= { radwinNetworkingFamiliy 1} oduS OBJECT IDENTIFIER ::= { radwinNetworkingFamiliy 2} END