myst:
html_meta:
description: "The Instrument, Measurement, and Command building blocks"
---
# Library
{.lead}
The `Instrument`, `Measurement`, and `Command` building blocks
This page gives a conceptual overview of how `instro` is structured.
## Instrument
{py:obj}`Instrument ` is the base class for [all instrument types](/instruments.md). Its responsibilities include:
* Creates and holds the communication interface for the instrument.
* Publishing `Measurements and Commands` to any attached `Publishers`.
* Handling background daemons for synchronous instrument communication.
```py
from instro.lib import Instrument
Instrument(
name: str,
publishers: list[Publisher] | None = None,
background_config: BackgroundDaemonConfig | None = None,
legacy_naming: bool = False,
**kwargs,
)
```
User defined [custom instruments](/library/custom-instruments.md) should subclass {py:obj}`Instrument `
## Measurements and Commands
When controlling an {py:obj}`Instrument ` gets and sets return {py:obj}`Measurement ` and {py:obj}`Command ` objects.
* A {py:obj}`Measurement ` is created when **reading data** from an instrument.
```py
from instro.lib import Measurement
Measurement(
channel_data: dict[str, list[float] | list[str]],
timestamps: list[int],
tags: dict[str, str] | None = None,
)
```
* A {py:obj}`Command ` is created when **writing commands** to an instrument.
```py
from instro.lib import Command
Command(
channel_data: dict[str, float | str],
timestamp: int,
tags: dict[str, str] | None = None,
)
```
Unlike {py:obj}`Measurement `, a {py:obj}`Command ` carries a single datapoint per channel (`float | str`, not `list[float]`) and a single `timestamp`. The `str` option covers categorical commands whose value is not numeric: mode names and relay states such as `OPEN` / `CLOSED`. A categorical *read* (a mode name or state reported back from the instrument) is a string-valued {py:obj}`Measurement `, not a {py:obj}`Command `: writes are always {py:obj}`Command ` and always publish to a `.cmd` channel; reads are always {py:obj}`Measurement `, whatever the value's type, and never publish to a `.cmd` channel.
### Parameters
- **`channel_data: dict[str, list[float] | list[str]]`**
This dictionary maps {abbr}`channel (A named signal for a series of measurements or computed values, example: voltage, pressure, system state.)` names (or numbers, as strings) to lists of numeric or categorical measurements. A given channel's list is always one type or the other, never mixed. For example, if your instrument has channels `"my_thermocouple1"` and `"my_thermocouple2"`, and you collected 10 samples from each, `channel_data` might look like:
```python
{
"my_thermocouple1": [0.123, 0.124, ...],
"my_thermocouple2": [0.223, 0.224, ...],
}
```
- **`timestamps: list[int]`**
A list of timestamps in integer nanoseconds since the Unix epoch, one per measurement sample, aligned with the values in `channel_data`. The length of `timestamps` should match the length of each list in `channel_data`.
- **`tags: dict[str, str] | None`**
Optional metadata associated with this measurement acquisition. Common tags include test IDs, operator name, or environmental qualifiers. Useful for search, provenance, and analysis.
## High Level Architecture
1. **Instrument Types / HALs**: Distinct classes for each type of instrument (e.g., DAQ, PSU, ELoad, I2C), each providing an opinionated and unified usage model. This design exposes a tailored interface that reflects typical usage patterns, making common workflows consistent across different vendors and models.
2. **Drivers**: Vendor- or model-specific drivers that handle low-level communication intricacies. HALs rely on these drivers to implement vendor- or model-specific details within the context of their higher level usage model.
3. **Publishers**: Components responsible for recording or transmitting instrument data and commands. For example, streaming measurement data to a dataset. Instruments own attached publishers and close them during teardown.

## Backwards-compatible channel naming (`legacy_naming`)
Every category instrument accepts a `legacy_naming: bool = False` keyword at construction. When set to `True`, the instrument publishes channels under their pre-v1.0 names.
```python
# Default (v1.0): publishes main.ch1.voltage, main.ch1.voltage.cmd, ...
psu_new = InstroPSU(name="main", driver=BK9115(...), num_channels=1)
# Legacy: publishes main.ch1_v, main.ch1_v.cmd, ...
psu_legacy = InstroPSU(name="main", driver=BK9115(...), num_channels=1, legacy_naming=True)
```
**When to use it:**
- **Backwards compatibility.** If your dashboards or recorded datasets were keyed on the pre-v1.0 channel names, flip the flag on each instrument as a single-line stopgap while you update downstream consumers.
**Scope:**
- Categories with a v1.0 rename (PSU, ELoad, I2C, DAQ digital channels, and `InstroScope`) honor the flag.
- Categories with no v1.0 rename (DMM, Modbus, DAQ analog/relay) ignore the flag (the published names are unchanged either way).
**Limitations:**
- All-or-nothing per instrument. There is no way to use new names for some channels and legacy for others on the same instance.
- `legacy_naming` is scheduled for **removal in v2.0**. Plan to migrate downstream consumers within that window.