# Metrics SDK **Status**: [Mixed](../document-status.md)
Table of Contents - [MeterProvider](#meterprovider) * [MeterProvider Creation](#meterprovider-creation) * [Meter Creation](#meter-creation) * [Configuration](#configuration) + [MeterConfigurator](#meterconfigurator) * [Shutdown](#shutdown) * [ForceFlush](#forceflush) * [View](#view) + [Instrument selection criteria](#instrument-selection-criteria) + [Stream configuration](#stream-configuration) + [Measurement processing](#measurement-processing) + [View examples](#view-examples) * [Aggregation](#aggregation) + [Drop Aggregation](#drop-aggregation) + [Default Aggregation](#default-aggregation) + [Sum Aggregation](#sum-aggregation) + [Last Value Aggregation](#last-value-aggregation) + [Histogram Aggregations](#histogram-aggregations) - [Explicit Bucket Histogram Aggregation](#explicit-bucket-histogram-aggregation) - [Base2 Exponential Bucket Histogram Aggregation](#base2-exponential-bucket-histogram-aggregation) * [Handle all normal values](#handle-all-normal-values) * [Support a minimum and maximum scale](#support-a-minimum-and-maximum-scale) * [Use the maximum scale for single measurements](#use-the-maximum-scale-for-single-measurements) * [Maintain the ideal scale](#maintain-the-ideal-scale) * [Observations inside asynchronous callbacks](#observations-inside-asynchronous-callbacks) * [Cardinality limits](#cardinality-limits) + [Configuration](#configuration-1) + [Overflow attribute](#overflow-attribute) + [Synchronous instrument cardinality limits](#synchronous-instrument-cardinality-limits) + [Asynchronous instrument cardinality limits](#asynchronous-instrument-cardinality-limits) - [Meter](#meter) * [MeterConfig](#meterconfig) * [Duplicate instrument registration](#duplicate-instrument-registration) + [Name conflict](#name-conflict) * [Instrument name](#instrument-name) * [Instrument unit](#instrument-unit) * [Instrument description](#instrument-description) * [Instrument advisory parameters](#instrument-advisory-parameters) + [Instrument advisory parameter: `ExplicitBucketBoundaries`](#instrument-advisory-parameter-explicitbucketboundaries) + [Instrument advisory parameter: `Attributes`](#instrument-advisory-parameter-attributes) * [Instrument enabled](#instrument-enabled) - [Attribute limits](#attribute-limits) - [Exemplar](#exemplar) * [ExemplarFilter](#exemplarfilter) + [AlwaysOn](#alwayson) + [AlwaysOff](#alwaysoff) + [TraceBased](#tracebased) * [ExemplarReservoir](#exemplarreservoir) * [Exemplar defaults](#exemplar-defaults) + [SimpleFixedSizeExemplarReservoir](#simplefixedsizeexemplarreservoir) + [AlignedHistogramBucketExemplarReservoir](#alignedhistogrambucketexemplarreservoir) * [Custom ExemplarReservoir](#custom-exemplarreservoir) - [MetricReader](#metricreader) * [MetricReader operations](#metricreader-operations) + [Collect](#collect) + [Shutdown](#shutdown-1) * [Periodic exporting MetricReader](#periodic-exporting-metricreader) + [ForceFlush](#forceflush-1) - [MetricExporter](#metricexporter) * [Push Metric Exporter](#push-metric-exporter) + [Interface Definition](#interface-definition) - [Export(batch)](#exportbatch) - [ForceFlush](#forceflush-2) - [Shutdown](#shutdown-2) * [Pull Metric Exporter](#pull-metric-exporter) - [MetricProducer](#metricproducer) * [Interface Definition](#interface-definition-1) + [Produce batch](#produce-batch) - [MetricFilter](#metricfilter) * [Interface Definition](#interface-definition-2) + [TestMetric](#testmetric) + [TestAttributes](#testattributes) - [Defaults and configuration](#defaults-and-configuration) - [Numerical limits handling](#numerical-limits-handling) - [Compatibility requirements](#compatibility-requirements) - [Concurrency requirements](#concurrency-requirements) - [References](#references)
Users of OpenTelemetry need a way for instrumentation interactions with the OpenTelemetry API to actually produce telemetry. The OpenTelemetry SDK (henceforth referred to as the SDK) is an implementation of the OpenTelemetry API that provides users with this functionally. All language implementations of OpenTelemetry MUST provide an SDK. ## MeterProvider **Status**: [Stable](../document-status.md) A `MeterProvider` MUST provide a way to allow a [Resource](../resource/sdk.md) to be specified. If a `Resource` is specified, it SHOULD be associated with all the metrics produced by any `Meter` from the `MeterProvider`. The [tracing SDK specification](../trace/sdk.md#additional-span-interfaces) has provided some suggestions regarding how to implement this efficiently. ### MeterProvider Creation The SDK SHOULD allow the creation of multiple independent `MeterProvider`s. ### Meter Creation It SHOULD only be possible to create `Meter` instances through a `MeterProvider` (see [API](./api.md#meterprovider)). The `MeterProvider` MUST implement the [Get a Meter API](api.md#get-a-meter). The input provided by the user MUST be used to create an [`InstrumentationScope`](../glossary.md#instrumentation-scope) instance which is stored on the created `Meter`. In the case where an invalid `name` (null or empty string) is specified, a working Meter MUST be returned as a fallback rather than returning null or throwing an exception, its `name` SHOULD keep the original invalid value, and a message reporting that the specified value is invalid SHOULD be logged. **Status**: [Development](../document-status.md) - The `MeterProvider` MUST compute the relevant [MeterConfig](#meterconfig) using the configured [MeterConfigurator](#meterconfigurator), and create a `Meter` whose behavior conforms to that `MeterConfig`. ### Configuration Configuration ( i.e. [MetricExporters](#metricexporter), [MetricReaders](#metricreader), [Views](#view), and (**Development**) [MeterConfigurator](#meterconfigurator)) MUST be owned by the `MeterProvider`. The configuration MAY be applied at the time of `MeterProvider` creation if appropriate. The `MeterProvider` MAY provide methods to update the configuration. If configuration is updated (e.g., adding a `MetricReader`), the updated configuration MUST also apply to all already returned `Meters` (i.e. it MUST NOT matter whether a `Meter` was obtained from the `MeterProvider` before or after the configuration change). Note: Implementation-wise, this could mean that `Meter` instances have a reference to their `MeterProvider` and access configuration only via this reference. #### MeterConfigurator **Status**: [Development](../document-status.md) A `MeterConfigurator` is a function which computes the [MeterConfig](#meterconfig) for a [Meter](#meter). The function MUST accept the following parameter: * `meter_scope`: The [`InstrumentationScope`](../glossary.md#instrumentation-scope) of the `Meter`. The function MUST return the relevant `MeterConfig`, or some signal indicating that the [default MeterConfig](#meterconfig) should be used. This signal MAY be nil, null, empty, or an instance of the default `MeterConfig` depending on what is idiomatic in the language. This function is called when a `Meter` is first created, and for each outstanding `Meter` when a `MeterProvider`'s `MeterConfigurator` is updated (if updating is supported). Therefore, it is important that it returns quickly. `MeterConfigurator` is modeled as a function to maximize flexibility. However, implementations MAY provide shorthand or helper functions to accommodate common use cases: * Select one or more Meters by name, with exact match or pattern matching. * Disable one or more specific Meters. * Disable all Meters, and selectively enable one or more specific Meters. ### Shutdown This method provides a way for provider to do any cleanup required. `Shutdown` MUST be called only once for each `MeterProvider` instance. After the call to `Shutdown`, subsequent attempts to get a `Meter` are not allowed. SDKs SHOULD return a valid no-op Meter for these calls, if possible. `Shutdown` SHOULD provide a way to let the caller know whether it succeeded, failed or timed out. `Shutdown` SHOULD complete or abort within some timeout. `Shutdown` MAY be implemented as a blocking API or an asynchronous API which notifies the caller via a callback or an event. [OpenTelemetry SDK](../overview.md#sdk) authors MAY decide if they want to make the shutdown timeout configurable. `Shutdown` MUST be implemented at least by invoking `Shutdown` on all registered [MetricReader](#metricreader) and [MetricExporter](#metricexporter) instances. ### ForceFlush This method provides a way for provider to notify the registered [MetricReader](#metricreader) instances that have an associated [Push Metric Exporter](#push-metric-exporter), so they can do as much as they could to collect and send the metrics. Note: [Pull Metric Exporter](#pull-metric-exporter) can only send the data when it is being asked by the scraper, so `ForceFlush` would not make much sense. `ForceFlush` MUST invoke `ForceFlush` on all registered [MetricReader](#metricreader) instances that implement `ForceFlush`. `ForceFlush` SHOULD provide a way to let the caller know whether it succeeded, failed or timed out. `ForceFlush` SHOULD return some **ERROR** status if there is an error condition; and if there is no error condition, it should return some **NO ERROR** status, language implementations MAY decide how to model **ERROR** and **NO ERROR**. `ForceFlush` SHOULD complete or abort within some timeout. `ForceFlush` MAY be implemented as a blocking API or an asynchronous API which notifies the caller via a callback or an event. [OpenTelemetry SDK](../overview.md#sdk) authors MAY decide if they want to make the flush timeout configurable. ### View A `View` provides SDK users with the flexibility to customize the metrics that are output by the SDK. Here are some examples when a `View` might be needed: * Customize which [Instruments](./api.md#instrument) are to be processed/ignored. For example, an [instrumented library](../glossary.md#instrumented-library) can provide both temperature and humidity, but the application developer might only want temperature. * Customize the aggregation - if the default aggregation associated with the Instrument does not meet the needs of the user. For example, an HTTP client library might expose HTTP client request duration as [Histogram](./api.md#histogram) by default, but the application developer might only want the total count of outgoing requests. * Customize which attribute(s) are to be reported on metrics. For example, an HTTP server library might expose HTTP verb (e.g. GET, POST) and HTTP status code (e.g. 200, 301, 404). The application developer might only care about HTTP status code (e.g. reporting the total count of HTTP requests for each HTTP status code). There could also be extreme scenarios in which the application developer does not need any attributes (e.g. just get the total count of all incoming requests). The SDK MUST provide functionality for a user to create Views for a `MeterProvider`. This functionality MUST accept as inputs the [Instrument selection criteria](#instrument-selection-criteria) and the resulting [stream configuration](#stream-configuration). The SDK MUST provide the means to register Views with a `MeterProvider`. #### Instrument selection criteria Instrument selection criteria are the predicates that determine if a View will be applied to an Instrument or not. Criteria SHOULD be treated as additive. This means an Instrument has to match _all_ the provided criteria for the View to be applied. For example, if the criteria are _instrument name == "Foobar"_ and _instrument type is Histogram_, it will be treated as _(instrument name == "Foobar") AND (instrument type is Histogram)_. The SDK MUST accept the following criteria: * `name`: The name of the Instrument(s) to match. This `name` is evaluated to match an Instrument in the following manner. 1. If the value of `name` is `*`, the criterion matches all Instruments. 2. If the value of `name` is exactly the same as an Instrument, then the criterion matches that instrument. Additionally, the SDK MAY support wildcard pattern matching for the `name` criterion using the following characters. * A question mark (`?`): matches any single character * An asterisk (`*`): matches any number of any characters including none If wildcard pattern matching is supported, the `name` criterion will match if the wildcard pattern is evaluated to match the Instrument name. If the SDK does not support wildcards in general, it MUST still recognize the special single asterisk (`*`) character as matching all Instruments. Users can provide a `name`, but it is up to their discretion. Therefore, the instrument selection criteria parameter needs to be structured to accept a `name`, but MUST NOT obligate a user to provide one. * `type`: The type of Instruments to match. If the value of `type` is the same as an Instrument's type, then the criterion matches that Instrument. Users can provide a `type`, but it is up to their discretion. Therefore, the instrument selection criteria parameter needs to be structured to accept a `type`, but MUST NOT obligate a user to provide one. * `unit`: If the value of `unit` is the same as an Instrument's unit, then the criterion matches that Instrument. Users can provide a `unit`, but it is up to their discretion. Therefore, the instrument selection criteria parameter needs to be structured to accept a `unit`, but MUST NOT obligate a user to provide one. * `meter_name`: If the value of `meter_name` is the same as the Meter that created an Instrument, then the criterion matches that Instrument. Users can provide a `meter_name`, but it is up to their discretion. Therefore, the instrument selection criteria parameter needs to be structured to accept a `meter_name`, but MUST NOT obligate a user to provide one. * `meter_version`: If the value of `meter_version` is the same version as the Meter that created an Instrument, then the criterion matches that Instrument. Users can provide a `meter_version`, but it is up to their discretion. Therefore, the instrument selection criteria parameter needs to be structured to accept a `meter_version`, but MUST NOT obligate a user to provide one. * `meter_schema_url`: If the value of `meter_schema_url` is the same schema URL as the Meter that created an Instrument, then the criterion matches that Instrument. Users can provide a `meter_schema_url`, but it is up to their discretion. Therefore, the instrument selection criteria parameter needs to be structured to accept a `meter_schema_url`, but MUST NOT obligate a user to provide one. The SDK MAY accept additional criteria. For example, a strongly typed language may support point type criterion (e.g. allow the users to select Instruments based on whether the underlying number is integral or rational). Users can provide these additional criteria the SDK accepts, but it is up to their discretion. Therefore, the instrument selection criteria can be structured to accept the criteria, but MUST NOT obligate a user to provide them. #### Stream configuration Stream configuration are the parameters that define the [metric stream](./data-model.md#events--data-stream--timeseries) a `MeterProvider` will use to define telemetry pipelines. The SDK MUST accept the following stream configuration parameters: * `name`: The metric stream name that SHOULD be used. In order to avoid conflicts, if a `name` is provided the View SHOULD have an instrument selector that selects at most one instrument. If the Instrument selection criteria for a View with a stream configuration `name` parameter can select more than one instrument (i.e. wildcards) the SDK MAY fail fast in accordance with initialization [error handling principles](../error-handling.md#basic-error-handling-principles). Users can provide a `name`, but it is up to their discretion. Therefore, the stream configuration parameter needs to be structured to accept a `name`, but MUST NOT obligate a user to provide one. If the user does not provide a `name` value, name from the Instrument the View matches MUST be used by default. * `description`: The metric stream description that SHOULD be used. Users can provide a `description`, but it is up to their discretion. Therefore, the stream configuration parameter needs to be structured to accept a `description`, but MUST NOT obligate a user to provide one. If the user does not provide a `description` value, the description from the Instrument a View matches MUST be used by default. * `attribute_keys`: This is, at a minimum, an allow-list of attribute keys for measurements captured in the metric stream. The allow-list contains attribute keys that identify the attributes that MUST be kept, and all other attributes MUST be ignored. Implementations MAY accept additional attribute filtering functionality for this parameter. Users can provide `attribute_keys`, but it is up to their discretion. Therefore, the stream configuration parameter needs to be structured to accept `attribute_keys`, but MUST NOT obligate a user to provide them. If the user does not provide any value, the SDK SHOULD use the [`Attributes`](./api.md#instrument-advisory-parameters) advisory parameter configured on the instrument instead. If the `Attributes` advisory parameter is absent, all attributes MUST be kept. Additionally, implementations SHOULD support configuring an exclude-list of attribute keys. The exclude-list contains attribute keys that identify the attributes that MUST be excluded, all other attributes MUST be kept. If an attribute key is both included and excluded, the SDK MAY fail fast in accordance with initialization [error handling principles](../error-handling.md#basic-error-handling-principles). * `aggregation`: The name of an [aggregation](#aggregation) function to use in aggregating the metric stream data. Users can provide an `aggregation`, but it is up to their discretion. Therefore, the stream configuration parameter needs to be structured to accept an `aggregation`, but MUST NOT obligate a user to provide one. If the user does not provide an `aggregation` value, the `MeterProvider` MUST apply a [default aggregation](#default-aggregation) configurable on the basis of instrument type according to the [MetricReader](#metricreader) instance. * `exemplar_reservoir`: A functional type that generates an exemplar reservoir a `MeterProvider` will use when storing exemplars. This functional type needs to be a factory or callback similar to aggregation selection functionality which allows different reservoirs to be chosen by the aggregation. Users can provide an `exemplar_reservoir`, but it is up to their discretion. Therefore, the stream configuration parameter needs to be structured to accept an `exemplar_reservoir`, but MUST NOT obligate a user to provide one. If the user does not provide an `exemplar_reservoir` value, the `MeterProvider` MUST apply a [default exemplar reservoir](#exemplar-defaults). * `aggregation_cardinality_limit`: A positive integer value defining the maximum number of data points allowed to be emitted in a collection cycle by a single instrument. See [cardinality limits](#cardinality-limits), below. Users can provide an `aggregation_cardinality_limit`, but it is up to their discretion. Therefore, the stream configuration parameter needs to be structured to accept an `aggregation_cardinality_limit`, but MUST NOT obligate a user to provide one. If the user does not provide an `aggregation_cardinality_limit` value, the `MeterProvider` MUST apply the [default aggregation cardinality limit](#metricreader) the `MetricReader` is configured with. #### Measurement processing The SDK SHOULD use the following logic to determine how to process Measurements made with an Instrument: * Determine the `MeterProvider` which "owns" the Instrument. * If the `MeterProvider` has no `View` registered, take the Instrument and apply the default Aggregation on the basis of instrument kind according to the [MetricReader](#metricreader) instance's `aggregation` property. [Instrument advisory parameters](#instrument-advisory-parameters), if any, MUST be honored. * If the `MeterProvider` has one or more `View`(s) registered: * If the Instrument could match the instrument selection criteria, for each View: * Try to apply the View's stream configuration independently of any other Views registered for the same matching Instrument (i.e. Views are not merged). This may result in [conflicting metric identities](./data-model.md#opentelemetry-protocol-data-model-producer-recommendations) even if stream configurations specify non-overlapping properties (e.g. one View setting `aggregation` and another View setting `attribute_keys`, both leaving the stream `name` as the default configured by the Instrument). If applying the View results in conflicting metric identities the implementation SHOULD apply the View and emit a warning. If it is not possible to apply the View without producing semantic errors (e.g. the View sets an asynchronous instrument to use the [Explicit bucket histogram aggregation](#explicit-bucket-histogram-aggregation)) the implementation SHOULD emit a warning and proceed as if the View did not If both a View and [Instrument advisory parameters](#instrument-advisory-parameters) specify the same aspect of the [Stream configuration](#stream-configuration), the setting defined by the View MUST take precedence over the advisory parameters. * If the Instrument could not match with any of the registered `View`(s), the SDK SHOULD enable the instrument using the default aggregation and temporality. Users can configure match-all Views using [Drop aggregation](#drop-aggregation) to disable instruments by default. #### View examples The following are examples of an SDK's functionality to create Views for a `MeterProvider`. ```python # Python ''' +------------------+ | MeterProvider | | Meter A | | Counter X | | Histogram Y | | Meter B | | Gauge Z | +------------------+ ''' # metrics from X and Y (reported as Foo and Bar) will be exported meter_provider .add_view("X") .add_view("Foo", instrument_name="Y") .add_view( "Bar", instrument_name="Y", aggregation=HistogramAggregation(buckets=[5.0, 10.0, 25.0, 50.0, 100.0])) .add_metric_reader(PeriodicExportingMetricReader(ConsoleExporter())) ``` ```python # all the metrics will be exported using the default configuration meter_provider.add_metric_reader(PeriodicExportingMetricReader(ConsoleExporter())) ``` ```python # all the metrics will be exported using the default configuration meter_provider .add_view("*") # a wildcard view that matches everything .add_metric_reader(PeriodicExportingMetricReader(ConsoleExporter())) ``` ```python # Counter X will be exported as cumulative sum meter_provider .add_view("X", aggregation=SumAggregation()) .add_metric_reader(PeriodicExportingMetricReader(ConsoleExporter())) ``` ```python # Counter X will be exported as a delta sum and the default attributes # Counter X, Histogram Y, and Gauge Z will be exported with 2 attributes (a and b) # A warning will be emitted for conflicting metric identities on Counter X (as two Views matching that Instrument # are configured with the same default name X) and streams from both views will be exported meter_provider .add_view("X", aggregation=SumAggregation()) .add_view("*", attribute_keys=["a", "b"]) # wildcard view matches everything, including X .add_metric_reader(PeriodicExportingMetricReader(ConsoleExporter()), temporality=lambda kind: Delta if kind in [Counter, AsyncCounter, Histogram] else Cumulative) ``` ```python # Only Counter X will be exported, with the default configuration (match-all drop aggregation does not result in # conflicting metric identities) meter_provider .add_view("X") .add_view("*", aggregation=DropAggregation()) # a wildcard view to disable all instruments .add_metric_reader(PeriodicExportingMetricReader(ConsoleExporter())) ``` ### Aggregation An `Aggregation`, as configured via the [View](./sdk.md#view), informs the SDK on the ways and means to compute [Aggregated Metrics](./data-model.md#opentelemetry-protocol-data-model) from incoming Instrument [Measurements](./api.md#measurement). Note: the term _aggregation_ is used instead of _aggregator_. It is RECOMMENDED that implementors reserve the "aggregator" term for the future when the SDK allows custom aggregation implementations. An `Aggregation` specifies an operation (i.e. [decomposable aggregate function](https://en.wikipedia.org/wiki/Aggregate_function#Decomposable_aggregate_functions) like Sum, Histogram, Min, Max, Count) and optional configuration parameter overrides. The operation's default configuration parameter values will be used unless overridden by optional configuration parameter overrides. Note: Implementors MAY choose the best idiomatic practice for their language to represent the semantic of an Aggregation and optional configuration parameters. e.g. The View specifies an Aggregation by string name (i.e. "ExplicitBucketHistogram"). ```python # Use Histogram with custom boundaries meter_provider .add_view( "X", aggregation="ExplicitBucketHistogram", aggregation_params={"Boundaries": [0, 10, 100]} ) ``` e.g. The View specifies an Aggregation by class/type instance. ```c# // Use Histogram with custom boundaries meterProviderBuilder .AddView( instrumentName: "X", aggregation: new ExplicitBucketHistogramAggregation( boundaries: new double[] { 0.0, 10.0, 100.0 } ) ); ``` The SDK MUST provide the following `Aggregation` to support the [Metric Points](./data-model.md#metric-points) in the [Metrics Data Model](./data-model.md). - [Drop](./sdk.md#drop-aggregation) - [Default](./sdk.md#default-aggregation) - [Sum](./sdk.md#sum-aggregation) - [Last Value](./sdk.md#last-value-aggregation) - [Explicit Bucket Histogram](./sdk.md#explicit-bucket-histogram-aggregation) The SDK SHOULD provide the following `Aggregation`: - [Base2 Exponential Bucket Histogram](./sdk.md#base2-exponential-bucket-histogram-aggregation) #### Drop Aggregation The Drop Aggregation informs the SDK to ignore/drop all Instrument Measurements for this Aggregation. This Aggregation does not have any configuration parameters. #### Default Aggregation The Default Aggregation informs the SDK to use the Instrument `kind` to select an aggregation and `advisory` parameters to influence aggregation configuration parameters (as noted in the "Selected Aggregation" column). | Instrument Kind | Selected Aggregation | |-------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | [Counter](./api.md#counter) | [Sum Aggregation](./sdk.md#sum-aggregation) | | [Asynchronous Counter](./api.md#asynchronous-counter) | [Sum Aggregation](./sdk.md#sum-aggregation) | | [UpDownCounter](./api.md#updowncounter) | [Sum Aggregation](./sdk.md#sum-aggregation) | | [Asynchronous UpDownCounter](./api.md#asynchronous-updowncounter) | [Sum Aggregation](./sdk.md#sum-aggregation) | | [Gauge](./api.md#gauge) | [Last Value Aggregation](./sdk.md#last-value-aggregation) | | [Asynchronous Gauge](./api.md#asynchronous-gauge) | [Last Value Aggregation](./sdk.md#last-value-aggregation) | | [Histogram](./api.md#histogram) | [Explicit Bucket Histogram Aggregation](./sdk.md#explicit-bucket-histogram-aggregation), with the `ExplicitBucketBoundaries` [advisory parameter](./api.md#instrument-advisory-parameters) if provided | This Aggregation does not have any configuration parameters. #### Sum Aggregation The Sum Aggregation informs the SDK to collect data for the [Sum Metric Point](./data-model.md#sums). The monotonicity of the aggregation is determined by the instrument type: | Instrument Kind | `SumType` | |-------------------------------------------------------------------|---------------| | [Counter](./api.md#counter) | Monotonic | | [UpDownCounter](./api.md#updowncounter) | Non-Monotonic | | [Histogram](./api.md#histogram) | Monotonic | | [Gauge](./api.md#gauge) | Non-Monotonic | | [Asynchronous Gauge](./api.md#asynchronous-gauge) | Non-Monotonic | | [Asynchronous Counter](./api.md#asynchronous-counter) | Monotonic | | [Asynchronous UpDownCounter](./api.md#asynchronous-updowncounter) | Non-Monotonic | This Aggregation does not have any configuration parameters. This Aggregation informs the SDK to collect: - The arithmetic sum of `Measurement` values. #### Last Value Aggregation The Last Value Aggregation informs the SDK to collect data for the [Gauge Metric Point](./data-model.md#gauge). This Aggregation does not have any configuration parameters. This Aggregation informs the SDK to collect: - The last `Measurement`. - The timestamp of the last `Measurement`. #### Histogram Aggregations All histogram Aggregations inform the SDK to collect: - Count of `Measurement` values in population. - Arithmetic sum of `Measurement` values in population. This SHOULD NOT be collected when used with instruments that record negative measurements (e.g. `UpDownCounter` or `ObservableGauge`). - Min (optional) `Measurement` value in population. - Max (optional) `Measurement` value in population. ##### Explicit Bucket Histogram Aggregation The Explicit Bucket Histogram Aggregation informs the SDK to collect data for the [Histogram Metric Point](./data-model.md#histogram) using a set of explicit boundary values for histogram bucketing. This Aggregation honors the following configuration parameters: | Key | Value | Default Value | Description | | --- | --- | --- | --- | | Boundaries | double\[\] | [ 0, 5, 10, 25, 50, 75, 100, 250, 500, 750, 1000, 2500, 5000, 7500, 10000 ] | Array of increasing values representing explicit bucket boundary values.

The Default Value represents the following buckets (heavily influenced by the default buckets of Prometheus clients, e.g. [Java](https://github.com/prometheus/client_java/blob/6730f3e32199d6bf0e963b306ff69ef08ac5b178/simpleclient/src/main/java/io/prometheus/client/Histogram.java#L88) and [Go](https://github.com/prometheus/client_golang/blob/83d56b1144a0c2eb10d399e7abbae3333bebc463/prometheus/histogram.go#L68)):
(-∞, 0], (0, 5.0], (5.0, 10.0], (10.0, 25.0], (25.0, 50.0], (50.0, 75.0], (75.0, 100.0], (100.0, 250.0], (250.0, 500.0], (500.0, 750.0], (750.0, 1000.0], (1000.0, 2500.0], (2500.0, 5000.0], (5000.0, 7500.0], (7500.0, 10000.0], (10000.0, +∞). SDKs SHOULD use the default value when boundaries are not explicitly provided, unless they have good reasons to use something different (e.g. for backward compatibility reasons in a stable SDK release). | | RecordMinMax | true, false | true | Whether to record min and max. | Explicit buckets are stated in terms of their upper boundary. Buckets are exclusive of their lower boundary and inclusive of their upper bound (except at positive infinity). A measurement is defined to fall into the greatest-numbered bucket with boundary that is greater than or equal to the measurement. ##### Base2 Exponential Bucket Histogram Aggregation The Base2 Exponential Histogram Aggregation informs the SDK to collect data for the [Exponential Histogram Metric Point](./data-model.md#exponentialhistogram), which uses a base-2 exponential formula to determine bucket boundaries and an integer `scale` parameter to control resolution. Implementations adjust scale as necessary given the data. This Aggregation honors the following configuration parameters: | Key | Value | Default Value | Description | |--------------|-------------|---------------|--------------------------------------------------------------------------------------------------------------| | MaxSize | integer | 160 | Maximum number of buckets in each of the positive and negative ranges, not counting the special zero bucket. | | MaxScale | integer | 20 | Maximum `scale` factor. | | RecordMinMax | true, false | true | Whether to record min and max. | The default of 160 buckets is selected to establish default support for a high-resolution histogram able to cover a long-tail latency distribution from 1ms to 100s with less than 5% relative error. Because 160 can be factored into `10 * 2**K`, maximum contrast is relatively simple to derive for scale `K`: | Scale | Maximum data contrast at 10 * 2**K buckets | |-------|--------------------------------------------| | K+2 | 5.657 (2**(10/4)) | | K+1 | 32 (2**(10/2)) | | K | 1024 (2**10) | | K-1 | 1048576 (2**20) | The following table shows how the ideal scale for 160 buckets is calculated as a function of the input range: | Input range | Contrast | Ideal Scale | Base | Relative error | |-------------|----------|-------------|----------|----------------| | 1ms - 4ms | 4 | 6 | 1.010889 | 0.542% | | 1ms - 20ms | 20 | 5 | 1.021897 | 1.083% | | 1ms - 1s | 10**3 | 4 | 1.044274 | 2.166% | | 1ms - 100s | 10**5 | 3 | 1.090508 | 4.329% | | 1μs - 10s | 10**7 | 2 | 1.189207 | 8.643% | Note that relative error is calculated as half of the bucket width divided by the bucket midpoint, which is the same in every bucket. Using the bucket from [1, base), we have `(bucketWidth / 2) / bucketMidpoint = ((base - 1) / 2) / ((base + 1) / 2) = (base - 1) / (base + 1)`. This Aggregation uses the notion of "ideal" scale. The ideal scale is either: 1. The `MaxScale` (see configuration parameters), generally used for single-value histogram Aggregations where scale is not otherwise constrained. 2. The largest value of scale such that no more than the maximum number of buckets are needed to represent the full range of input data in either of the positive or negative ranges. ###### Handle all normal values Implementations are REQUIRED to accept the entire normal range of IEEE floating point values (i.e., all values except for +Inf, -Inf and NaN values). Implementations SHOULD NOT incorporate non-normal values (i.e., +Inf, -Inf, and NaNs) into the `sum`, `min`, and `max` fields, because these values do not map into a valid bucket. Implementations MAY round subnormal values away from zero to the nearest normal value. ###### Support a minimum and maximum scale The implementation MUST maintain reasonable minimum and maximum scale parameters that the automatic scale parameter will not exceed. The maximum scale is defined by the `MaxScale` configuration parameter. ###### Use the maximum scale for single measurements When the histogram contains not more than one value in either of the positive or negative ranges, the implementation SHOULD use the maximum scale. ###### Maintain the ideal scale Implementations SHOULD adjust the histogram scale as necessary to maintain the best resolution possible, within the constraint of maximum size (max number of buckets). Best resolution (highest scale) is achieved when the number of positive or negative range buckets exceeds half the maximum size, such that increasing scale by one would not be possible given the size constraint. ### Observations inside asynchronous callbacks Callback functions MUST be invoked for the specific `MetricReader` performing collection, such that observations made or produced by executing callbacks only apply to the intended `MetricReader` during collection. The implementation SHOULD disregard the use of asynchronous instrument APIs outside of registered callbacks. The implementation SHOULD use a timeout to prevent indefinite callback execution. The implementation MUST complete the execution of all callbacks for a given instrument before starting a subsequent round of collection. The implementation SHOULD NOT produce aggregated metric data for a previously-observed attribute set which is not observed during a successful callback. See [MetricReader](#metricreader) for more details on the persistence of metrics across successive collections. ### Cardinality limits **Status**: [Stable](../document-status.md) SDKs SHOULD support being configured with a cardinality limit. The number of unique combinations of attributes is called cardinality. For a given metric, the cardinality limit is a hard limit on the number of [Metric Points](./data-model.md#metric-points) that can be collected during a collection cycle. Cardinality limit enforcement SHOULD occur _after_ attribute filtering, if any. This ensures users can filter undesired attributes using [views](#view) and prevent reaching the cardinality limit. #### Configuration The cardinality limit for an aggregation is defined in one of three ways: 1. A [view](#view) with criteria matching the instrument an aggregation is created for has an `aggregation_cardinality_limit` value defined for the stream, that value SHOULD be used. 2. If there is no matching view, but the `MetricReader` defines a default cardinality limit value based on the instrument an aggregation is created for, that value SHOULD be used. 3. If none of the previous values are defined, the default value of 2000 SHOULD be used. #### Overflow attribute An overflow attribute set is defined, containing a single attribute `otel.metric.overflow` having (boolean) value `true`, which is used to report a synthetic aggregation of the [Measurements](./api.md#measurement) that could not be independently aggregated because of the limit. The SDK MUST create an Aggregator with the overflow attribute set prior to reaching the cardinality limit and use it to aggregate [Measurements](./api.md#measurement) for which the correct Aggregator could not be created. The SDK MUST provide the guarantee that overflow would not happen if the maximum number of distinct, non-overflow attribute sets is less than or equal to the limit. #### Synchronous instrument cardinality limits Aggregators for synchronous instruments with cumulative temporality MUST continue to export all attribute sets that were observed prior to the beginning of overflow. [Measurements](./api.md#measurement) corresponding with attribute sets that were not observed prior to the overflow will be reflected in a single data point described by (only) the overflow attribute. Aggregators of synchronous instruments with delta aggregation temporality MAY choose an arbitrary subset of attribute sets to output to maintain the stated cardinality limit. Regardless of aggregation temporality, the SDK MUST ensure that every [Measurement](./api.md#measurement) is reflected in exactly one Aggregator, which is either an Aggregator associated with the correct attribute set or an aggregator associated with the overflow attribute set. [Measurements](./api.md#measurement) MUST NOT be double-counted or dropped during an overflow. #### Asynchronous instrument cardinality limits Aggregators of asynchronous instruments SHOULD prefer the first-observed attributes in the callback when limiting cardinality, regardless of temporality. ## Meter Distinct meters MUST be treated as separate namespaces for the purposes of detecting [duplicate instrument registrations](#duplicate-instrument-registration). **Status**: [Development](../document-status.md) - `Meter` MUST behave according to the [MeterConfig](#meterconfig) computed during [Meter creation](#meter-creation). If the `MeterProvider` supports updating the [MeterConfigurator](#meterconfigurator), then upon update the `Meter` MUST be updated to behave according to the new `MeterConfig`. ### MeterConfig **Status**: [Development](../document-status.md) A `MeterConfig` defines various configurable aspects of a `Meter`'s behavior. It consists of the following parameters: * `disabled`: A boolean indication of whether the Meter is enabled. If not explicitly set, the `disabled` parameter SHOULD default to `false` ( i.e. `Meter`s are enabled by default). If a `Meter` is disabled, it MUST behave equivalently to [No-op Meter](./noop.md#meter). The value of `disabled` MUST be used to resolve whether an instrument is [Enabled](./api.md#enabled). See [Instrument Enabled](#instrument-enabled) for details. ### Duplicate instrument registration A _duplicate instrument registration_ occurs when more than one Instrument of the same [`name`](./api.md#instrument-name-syntax) is created for identical Meters from the same MeterProvider but they have different [identifying fields](./api.md#instrument). Whenever this occurs, users still need to be able to make measurements with the duplicate instrument. This means that the Meter MUST return a functional instrument that can be expected to export data even if this will cause [semantic error in the data model](data-model.md#opentelemetry-protocol-data-model-producer-recommendations). Additionally, users need to be informed about this error. Therefore, when a duplicate instrument registration occurs, and it is not corrected with a View, a warning SHOULD be emitted. The emitted warning SHOULD include information for the user on how to resolve the conflict, if possible. 1. If the potential conflict involves multiple `description` properties, setting the `description` through a configured View SHOULD avoid the warning. 2. If the potential conflict involves instruments that can be distinguished by a supported View selector (e.g. name, instrument kind) a renaming View recipe SHOULD be included in the warning. 3. Otherwise (e.g., use of multiple units), the SDK SHOULD pass through the data by reporting both `Metric` objects and emit a generic warning describing the duplicate instrument registration. It is unspecified whether or under which conditions the same or different Instrument instance will be returned as a result of duplicate instrument registration. The term _identical_ applied to Instruments describes instances where all [identifying fields](./api.md#instrument) are equal. The term _distinct_ applied to Instruments describes instances where at least one field value is different. To accommodate [the recommendations from the data model](data-model.md#opentelemetry-protocol-data-model-producer-recommendations), the SDK MUST aggregate data from [identical Instruments](api.md#instrument) together in its export pipeline. #### Name conflict The [`name`](./api.md#instrument-name-syntax) of an Instrument is defined to be case-insensitive. If an SDK uses a case-sensitive encoding to represent this `name`, a duplicate instrument registration will occur when a user passes multiple casings of the same `name`. When this happens, the Meter MUST return an instrument using the first-seen instrument name and log an appropriate error as described above. For example, if a user creates an instrument with the name `requestCount` and then makes another request to the same `Meter` to create an instrument with the name `RequestCount`, in both cases an instrument with the name `requestCount` needs to be returned to the user and a log message needs to be emitted for the second request. ### Instrument name When a Meter creates an instrument, it SHOULD validate the instrument name conforms to the [instrument name syntax](./api.md#instrument-name-syntax) If the instrument name does not conform to this syntax, the Meter SHOULD emit an error notifying the user about the invalid name. It is left unspecified if a valid instrument is also returned. ### Instrument unit When a Meter creates an instrument, it SHOULD NOT validate the instrument unit. If a unit is not provided or the unit is null, the Meter MUST treat it the same as an empty unit string. ### Instrument description When a Meter creates an instrument, it SHOULD NOT validate the instrument description. If a description is not provided or the description is null, the Meter MUST treat it the same as an empty description string. ### Instrument advisory parameters **Status**: [Stable](../document-status.md), except where otherwise specified When a Meter creates an instrument, it SHOULD validate the instrument advisory parameters. If an advisory parameter is not valid, the Meter SHOULD emit an error notifying the user and proceed as if the parameter was not provided. If multiple [identical Instruments](api.md#instrument) are created with different advisory parameters, the Meter MUST return an instrument using the first-seen advisory parameters and log an appropriate error as described in [duplicate instrument registrations](#duplicate-instrument-registration). If both a [View](#view) and advisory parameters specify the same aspect of the [Stream configuration](#stream-configuration), the setting defined by the View MUST take precedence over the advisory parameters. #### Instrument advisory parameter: `ExplicitBucketBoundaries` This advisory parameter applies when the [Explicit Bucket Histogram](#explicit-bucket-histogram-aggregation) aggregation is used. If a matching View specifies Explicit Bucket Histogram aggregation (with or without bucket boundaries), the `ExplicitBucketBoundaries` advisory parameter is ignored. If no View matches, or if a matching View selects the [default aggregation](#default-aggregation), the `ExplicitBucketBoundaries` advisory parameter MUST be used. If neither is provided, the default bucket boundaries apply. #### Instrument advisory parameter: `Attributes` **Status**: [Development](../document-status.md) This advisory parameter applies to all aggregations. `Attributes` (a list of [attribute keys](../common/README.md#attribute)) specifies the recommended set of attribute keys for measurements aggregated to produce a metric stream. If the user has provided attribute keys via View(s), those keys take precedence. If no View is configured, or if a matching view does not specify attribute keys, the advisory parameter should be used. If neither is provided, all attributes must be retained. ### Instrument enabled **Status**: [Development](../document-status.md) The instrument [Enabled](./api.md#enabled) operation MUST return `false` if any of the following conditions are true, and `true` otherwise: * The [MeterConfig](#meterconfig) of the `Meter` used to create the instrument has parameter `disabled=true`. * All [resolved views](#measurement-processing) for the instrument are configured with the [Drop Aggregation](#drop-aggregation). Note: If a user makes no configuration changes, `Enabled` returns `true` since by default `MeterConfig.disabled=false` and instruments use the default aggregation when no matching views match the instrument. It is not necessary for implementations to ensure that changes to `MeterConfig.disabled` are immediately visible to callers of `Enabled`. ## Attribute limits **Status**: [Stable](../document-status.md) Attributes which belong to Metrics are exempt from the [common rules of attribute limits](../common/README.md#attribute-limits) at this time. Attribute truncation or deletion could affect identity of metric time series and the topic requires further analysis. ## Exemplar **Status**: [Stable](../document-status.md) Exemplars are example data points for aggregated data. They provide specific context to otherwise general aggregations. Exemplars allow correlation between aggregated metric data and the original API calls where measurements are recorded. Exemplars work for trace-metric correlation across any metric, not just those that can also be derived from `Span`s. An [Exemplar](./data-model.md#exemplars) is a recorded [Measurement](./api.md#measurement) that exposes the following pieces of information: - The `value` of the `Measurement` that was recorded by the API call. - The `time` the API call was made to record a `Measurement`. - The set of [Attributes](../common/README.md#attribute) associated with the `Measurement` not already included in a metric data point. - The associated [trace id and span id](../trace/api.md#retrieving-the-traceid-and-spanid) of the active [Span within Context](../trace/api.md#determining-the-parent-span-from-a-context) of the `Measurement` at API call time. For example, if a user has configured a `View` to preserve the attributes: `X` and `Y`, but the user records a measurement as follows: ```javascript const span = tracer.startSpan('makeRequest'); api.context.with(api.trace.setSpan(api.context.active(), span), () => { // Record a measurement. cache_miss_counter.add(1, {"X": "x-value", "Y": "y-value", "Z": "z-value"}); ... span.end(); }) ``` Then an exemplar output in OTLP would consist of: - The `value` of 1. - The `time` when the `add` method was called. - The `Attributes` of `{"Z": "z-value"}`, as these are not preserved in the resulting metric point. - The trace/span id for the `makeRequest` span. While the metric data point for the counter would carry the attributes `X` and `Y`. A Metric SDK MUST provide a mechanism to sample `Exemplar`s from measurements via the `ExemplarFilter` and `ExemplarReservoir` hooks. `Exemplar` sampling SHOULD be turned on by default. If `Exemplar` sampling is off, the SDK MUST NOT have overhead related to exemplar sampling. A Metric SDK MUST allow exemplar sampling to leverage the configuration of metric aggregation. For example, Exemplar sampling of histograms should be able to leverage bucket boundaries. A Metric SDK SHOULD provide configuration for Exemplar sampling, specifically: - `ExemplarFilter`: filter which measurements can become exemplars. - `ExemplarReservoir`: storage and sampling of exemplars. ### ExemplarFilter The `ExemplarFilter` configuration MUST allow users to select between one of the built-in ExemplarFilters. While `ExemplarFilter` determines which measurements are _eligible_ for becoming an `Exemplar`, the `ExemplarReservoir` makes the final decision if a measurement becomes an exemplar and is stored. The ExemplarFilter SHOULD be a configuration parameter of a `MeterProvider` for an SDK. The default value SHOULD be `TraceBased`. The filter configuration SHOULD follow the [environment variable specification](../configuration/sdk-environment-variables.md#exemplar). An OpenTelemetry SDK MUST support the following filters: - [AlwaysOn](#alwayson) - [AlwaysOff](#alwaysoff) - [TraceBased](#tracebased) #### AlwaysOn An ExemplarFilter which makes all measurements eligible for being an Exemplar. #### AlwaysOff An ExemplarFilter which makes no measurements eligible for being an Exemplar. Using this ExemplarFilter is as good as disabling the Exemplar feature. #### TraceBased An ExemplarFilter which makes those measurements eligible for being an Exemplar, which are recorded in the context of a sampled parent span. ### ExemplarReservoir The `ExemplarReservoir` interface MUST provide a method to offer measurements to the reservoir and another to collect accumulated Exemplars. A new `ExemplarReservoir` MUST be created for every known timeseries data point, as determined by aggregation and view configuration. This data point, and its set of defining attributes, are referred to as the associated timeseries point. The "offer" method SHOULD accept measurements, including: - The `value` of the measurement. - The complete set of `Attributes` of the measurement. - The [Context](../context/README.md) of the measurement, which covers the [Baggage](../baggage/api.md) and the current active [Span](../trace/api.md#span). - A `timestamp` that best represents when the measurement was taken. The "offer" method SHOULD have the ability to pull associated trace and span information without needing to record full context. In other words, current span context and baggage can be inspected at this point. The "offer" method does not need to store all measurements it is given and MAY further sample beyond the `ExemplarFilter`. The "offer" method MAY accept a filtered subset of `Attributes` which diverge from the timeseries the reservoir is associated with. This MUST be clearly documented in the API and the reservoir MUST be given the `Attributes` associated with its timeseries point either at construction so that additional sampling performed by the reservoir has access to all attributes from a measurement in the "offer" method. SDK authors are encouraged to benchmark whether this option works best for their implementation. The "collect" method MUST return accumulated `Exemplar`s. Exemplars are expected to abide by the `AggregationTemporality` of any metric point they are recorded with. In other words, Exemplars reported against a metric data point SHOULD have occurred within the start/stop timestamps of that point. SDKs are free to decide whether "collect" should also reset internal storage for delta temporal aggregation collection, or use a more optimal implementation. `Exemplar`s MUST retain any attributes available in the measurement that are not preserved by aggregation or view configuration for the associated timeseries. Joining together attributes on an `Exemplar` with those available on its associated metric data point should result in the full set of attributes from the original sample measurement. The `ExemplarReservoir` SHOULD avoid allocations when sampling exemplars. ### Exemplar defaults The SDK MUST include two types of built-in exemplar reservoirs: 1. `SimpleFixedSizeExemplarReservoir` 2. `AlignedHistogramBucketExemplarReservoir` By default: - Explicit bucket histogram aggregation with more than 1 bucket SHOULD use `AlignedHistogramBucketExemplarReservoir`. - Base2 Exponential Histogram Aggregation SHOULD use a `SimpleFixedSizeExemplarReservoir` with a reservoir equal to the smaller of the maximum number of buckets configured on the aggregation or twenty (e.g. `min(20, max_buckets)`). - All other aggregations SHOULD use `SimpleFixedSizeExemplarReservoir`. Exemplar default reservoirs MAY change in a [minor version bump](./../versioning-and-stability.md#minor-version-bump). No guarantees are made on the shape or statistical properties of returned exemplars. #### SimpleFixedSizeExemplarReservoir This reservoir MUST use a uniformly-weighted sampling algorithm based on the number of samples the reservoir has seen so far to determine if the offered measurements should be sampled. For example, the [simple reservoir sampling algorithm](https://en.wikipedia.org/wiki/Reservoir_sampling) can be used: ``` if num_measurements_seen < num_buckets then bucket = num_measurements_seen else bucket = random_integer(0, num_measurements_seen) end if bucket < num_buckets then reservoir[bucket] = measurement end ``` Any stateful portion of sampling computation SHOULD be reset every collection cycle. For the above example, that would mean that the `num_measurements_seen` count is reset every time the reservoir is collected. This Exemplar reservoir MAY take a configuration parameter for the size of the reservoir. If no size configuration is provided, the default size MAY be the number of possible concurrent threads (e.g., number of CPUs) to help reduce contention. Otherwise, a default size of `1` SHOULD be used. #### AlignedHistogramBucketExemplarReservoir This Exemplar reservoir MUST take a configuration parameter that is the configuration of a Histogram. This implementation MUST keep the last seen measurement that falls within a histogram bucket. The reservoir will accept measurements using the equivalent of the following naive algorithm: ``` bucket = find_histogram_bucket(measurement) if bucket < num_buckets then reservoir[bucket] = measurement end def find_histogram_bucket(measurement): for boundary, idx in bucket_boundaries do if value <= boundary then return idx end end return boundaries.length ``` This Exemplar reservoir MAY take a configuration parameter for the bucket boundaries used by the reservoir. The size of the reservoir is always the number of bucket boundaries plus one. This configuration parameter SHOULD have the same format as specifying bucket boundaries to [Explicit Bucket Histogram Aggregation](./sdk.md#explicit-bucket-histogram-aggregation). ### Custom ExemplarReservoir The SDK MUST provide a mechanism for SDK users to provide their own ExemplarReservoir implementation. This extension MUST be configurable on a metric [View](#view), although individual reservoirs MUST still be instantiated per metric-timeseries (see [Exemplar Reservoir - Paragraph 2](#exemplarreservoir)). ## MetricReader **Status**: [Stable](../document-status.md) `MetricReader` is an SDK implementation object that provides the common configurable aspects of the OpenTelemetry Metrics SDK and determines the following capabilities: * Collecting metrics from the SDK and any registered [MetricProducers](#metricproducer) on demand. * Handling the [ForceFlush](#forceflush) and [Shutdown](#shutdown) signals from the SDK. To construct a `MetricReader` when setting up an SDK, at least the following SHOULD be provided: * The `exporter` to use, which is a `MetricExporter` instance. * The default output `aggregation` (optional), a function of instrument kind. This function SHOULD be obtained from the `exporter`. If not configured, the [default aggregation](#default-aggregation) SHOULD be used. * The output `temporality` (optional), a function of instrument kind. This function SHOULD be obtained from the `exporter`. If not configured, the Cumulative temporality SHOULD be used. * The default aggregation [cardinality limit](#cardinality-limits) (optional) to use, a function of instrument kind. If not configured, a default value of 2000 SHOULD be used. * **Status**: [Development](../document-status.md) - The [MetricFilter](#metricfilter) to apply to metrics and attributes during `MetricReader#Collect`. * Zero of more [MetricProducer](#metricproducer)s (optional) to collect metrics from in addition to metrics from the SDK. **Status**: [Development](../document-status.md) - A `MetricReader` SHOULD provide the [MetricFilter](#metricfilter) to the SDK or registered [MetricProducer](#metricproducer)(s) when calling the `Produce` operation. The [MetricReader.Collect](#collect) method allows general-purpose `MetricExporter` instances to explicitly initiate collection, commonly used with pull-based metrics collection. A common implementation of `MetricReader`, the [periodic exporting `MetricReader`](#periodic-exporting-metricreader) SHOULD be provided to be used typically with push-based metrics collection. The `MetricReader` MUST ensure that data points from OpenTelemetry [instruments](./api.md#instrument) are output in the configured aggregation temporality for each instrument kind. For synchronous instruments with Cumulative aggregation temporality, this means converting [Delta to Cumulative](supplementary-guidelines.md#synchronous-example-cumulative-aggregation-temporality) aggregation temporality. For asynchronous instruments with Delta temporality, this means converting [Cumulative to Delta](supplementary-guidelines.md#asynchronous-example-delta-temporality) aggregation temporality. The `MetricReader` is not required to ensure data points from a non-SDK [MetricProducer](#metricproducer) are output in the configured aggregation temporality, as these data points are not collected using OpenTelemetry instruments. The `MetricReader` selection of `temporality` as a function of instrument kind influences the persistence of metric data points across collections. For synchronous instruments with Cumulative aggregation temporality, [MetricReader.Collect](#collect) MUST receive data points exposed in previous collections regardless of whether new measurements have been recorded. For synchronous instruments with Delta aggregation temporality, [MetricReader.Collect](#collect) MUST only receive data points with measurements recorded since the previous collection. For asynchronous instruments with Delta or Cumulative aggregation temporality, [MetricReader.Collect](#collect) MUST only receive data points with measurements recorded since the previous collection. These rules apply to all metrics, not just those whose [point kinds](./data-model.md#point-kinds) includes an aggregation temporality field. The `MetricReader` selection of `temporality` as a function of instrument kind influences the starting timestamp (i.e. `StartTimeUnixNano`) of metrics data points received by [MetricReader.Collect](#collect). For instruments with Cumulative aggregation temporality, successive data points received by successive calls to [MetricReader.Collect](#collect) MUST repeat the same starting timestamps (e.g. `(T0, T1], (T0, T2], (T0, T3]`). For instruments with Delta aggregation temporality, successive data points received by successive calls to [MetricReader.Collect](#collect) MUST advance the starting timestamp ( e.g. `(T0, T1], (T1, T2], (T2, T3]`). The ending timestamp (i.e. `TimeUnixNano`) MUST always be equal to time the metric data point took effect, which is equal to when [MetricReader.Collect](#collect) was invoked. These rules apply to all metrics, not just those whose [point kinds](./data-model.md#point-kinds) includes an aggregation temporality field. See [data model temporality](./data-model.md#temporality) for more details. The SDK MUST support multiple `MetricReader` instances to be registered on the same `MeterProvider`, and the [MetricReader.Collect](#collect) invocation on one `MetricReader` instance SHOULD NOT introduce side-effects to other `MetricReader` instances. For example, if a `MetricReader` instance is receiving metric data points that have [delta temporality](./data-model.md#temporality), it is expected that SDK will update the time range - e.g. from (Tn, Tn+1] to (Tn+1, Tn+2] - **ONLY** for this particular `MetricReader` instance. The SDK MUST NOT allow a `MetricReader` instance to be registered on more than one `MeterProvider` instance. ```text +-----------------+ +--------------+ | | Metrics... | | | In-memory state +------------> MetricReader | | | | | +-----------------+ +--------------+ +-----------------+ +--------------+ | | Metrics... | | | In-memory state +------------> MetricReader | | | | | +-----------------+ +--------------+ ``` The SDK SHOULD provide a way to allow `MetricReader` to respond to [MeterProvider.ForceFlush](#forceflush) and [MeterProvider.Shutdown](#shutdown). [OpenTelemetry SDK](../overview.md#sdk) authors MAY decide the language idiomatic approach, for example, as `OnForceFlush` and `OnShutdown` callback functions. ### MetricReader operations #### Collect Collects the metrics from the SDK and any registered [MetricProducers](#metricproducer). If there are [asynchronous SDK Instruments](./api.md#asynchronous-instrument-api) involved, their callback functions will be triggered. `Collect` SHOULD provide a way to let the caller know whether it succeeded, failed or timed out. When the `Collect` operation fails or times out on some of the instruments, the SDK MAY return successfully collected results and a failed reasons list to the caller. `Collect` does not have any required parameters, however, [OpenTelemetry SDK](../overview.md#sdk) authors MAY choose to add parameters (e.g. callback, filter, timeout). [OpenTelemetry SDK](../overview.md#sdk) authors MAY choose the return value type, or do not return anything. `Collect` SHOULD invoke [Produce](#produce-batch) on registered [MetricProducers](#metricproducer). If the batch of metric points from `Produce` includes [Resource](../resource/sdk.md) information, `Collect` MAY replace the `Resource` from the MetricProducer with the `Resource` provided when constructing the MeterProvider instead. Note: it is expected that the `MetricReader.Collect` implementations will be provided by the SDK, so it is RECOMMENDED to prevent the user from accidentally overriding it, if possible (e.g. `final` in C++ and Java, `sealed` in C#). #### Shutdown This method provides a way for the `MetricReader` to do any cleanup required. `Shutdown` MUST be called only once for each `MetricReader` instance. After the call to `Shutdown`, subsequent invocations to `Collect` are not allowed. SDKs SHOULD return some failure for these calls, if possible. `Shutdown` SHOULD provide a way to let the caller know whether it succeeded, failed or timed out. `Shutdown` SHOULD complete or abort within some timeout. `Shutdown` MAY be implemented as a blocking API or an asynchronous API which notifies the caller via a callback or an event. [OpenTelemetry SDK](../overview.md#sdk) authors MAY decide if they want to make the shutdown timeout configurable. ### Periodic exporting MetricReader This is an implementation of the `MetricReader` which collects metrics based on a user-configurable time interval, and passes the metrics to the configured [Push Metric Exporter](#push-metric-exporter). Configurable parameters: * `exportIntervalMillis` - the time interval in milliseconds between two consecutive exports. The default value is 60000 (milliseconds). * `exportTimeoutMillis` - how long the export can run before it is cancelled. The default value is 30000 (milliseconds). The reader MUST synchronize calls to `MetricExporter`'s `Export` to make sure that they are not invoked concurrently. One possible implementation of periodic exporting MetricReader is to inherit from `MetricReader` and start a background task which calls the inherited `Collect()` method at the requested `exportIntervalMillis`. The reader's `Collect()` method may still be invoked by other callers. For example, * A user configures periodic exporting MetricReader with a push exporter and a 30 second interval. * At the first 30 second interval, the background task calls `Collect()` which passes metrics to the push exporter. * After 15 seconds, the user decides to flush metrics for just this reader. They call `Collect()` which passes metrics to the push exporter. * After another 15 seconds (at the end of the second 30 second interval), the background task calls `Collect()` which passes metrics to the push exporter. #### ForceFlush This method provides a way for the periodic exporting MetricReader so it can do as much as it could to collect and send the metrics. `ForceFlush` SHOULD collect metrics, call [`Export(batch)`](#exportbatch) and [`ForceFlush()`](#forceflush-2) on the configured [Push Metric Exporter](#push-metric-exporter). `ForceFlush` SHOULD provide a way to let the caller know whether it succeeded, failed or timed out. `ForceFlush` SHOULD return some **ERROR** status if there is an error condition; and if there is no error condition, it should return some **NO ERROR** status, language implementations MAY decide how to model **ERROR** and **NO ERROR**. `ForceFlush` SHOULD complete or abort within some timeout. `ForceFlush` MAY be implemented as a blocking API or an asynchronous API which notifies the caller via a callback or an event. ## MetricExporter **Status**: [Stable](../document-status.md) `MetricExporter` defines the interface that protocol-specific exporters MUST implement so that they can be plugged into OpenTelemetry SDK and support sending of telemetry data. Metric Exporters always have an _associated_ MetricReader. The `aggregation` and `temporality` properties used by the OpenTelemetry Metric SDK are determined when registering Metric Exporters through their associated MetricReader. OpenTelemetry language implementations MAY support automatically configuring the [MetricReader](#metricreader) to use for an Exporter. The goal of the interface is to minimize the burden of implementation for protocol-dependent telemetry exporters. The protocol exporter is expected to be primarily a simple telemetry data encoder and transmitter. Metric Exporter has access to the [aggregated metrics data](./data-model.md#timeseries-model). Metric Exporters SHOULD report an error condition for data output by the `MetricReader` with unsupported Aggregation or Aggregation Temporality, as this condition can be corrected by a change of `MetricReader` configuration. There could be multiple [Push Metric Exporters](#push-metric-exporter) or [Pull Metric Exporters](#pull-metric-exporter) or even a mixture of both configured at the same time on a given `MeterProvider` using one `MetricReader` for each exporter. Different exporters can run at different schedule, for example: * Exporter A is a push exporter which sends data every 1 minute. * Exporter B is a push exporter which sends data every 5 seconds. * Exporter C is a pull exporter which reacts to a scraper over HTTP. * Exporter D is a pull exporter which reacts to another scraper over a named pipe. ### Push Metric Exporter Push Metric Exporter sends metric data it receives from a paired [MetricReader](#metricreader). Here are some examples: * Sends the data based on a user configured schedule, e.g. every 1 minute. This MAY be accomplished by pairing the exporter with a [periodic exporting MetricReader](#periodic-exporting-metricreader). * Sends the data when there is a severe error. The following diagram shows `Push Metric Exporter`'s relationship to other components in the SDK: ```text +-----------------+ +---------------------------------+ | | Metrics... | | | In-memory state +------------> Periodic exporting MetricReader | | | | | +-----------------+ | +-----------------------+ | | | | | | | MetricExporter (push) +-------> Another process | | | | | +-----------------------+ | | | +---------------------------------+ ``` #### Interface Definition A Push Metric Exporter MUST support the following functions: ##### Export(batch) Exports a batch of [Metric Points](./data-model.md#metric-points). Protocol exporters that will implement this function are typically expected to serialize and transmit the data to the destination. The SDK MUST provide a way for the exporter to get the [Meter](./api.md#meter) information (e.g. name, version, etc.) associated with each `Metric Point`. `Export` should never be called concurrently with other `Export` calls for the same exporter instance. `Export` MUST NOT block indefinitely, there MUST be a reasonable upper limit after which the call must time out with an error result (Failure). Any retry logic that is required by the exporter is the responsibility of the exporter. The default SDK SHOULD NOT implement retry logic, as the required logic is likely to depend heavily on the specific protocol and backend the metrics are being sent to. **Parameters:** `batch` - a batch of [Metric Points](./data-model.md#metric-points). The exact data type of the batch is language specific, typically it is some kind of list. The exact type of `Metric Point` is language specific, and is typically optimized for high performance. Here are some examples: ```text +--------+ +--------+ +--------+ Batch: | Metric | | Metric | ... | Metric | +---+----+ +--------+ +--------+ | +--> name, unit, description, meter information, ... | | +-------------+ +-------------+ +-------------+ +--> MetricPoints: | MetricPoint | | MetricPoint | ... | MetricPoint | +-----+-------+ +-------------+ +-------------+ | +--> timestamps, attributes, value (or buckets), exemplars, ... ``` Refer to the [Metric Points](./data-model.md#metric-points) section from the Metrics Data Model specification for more details. Note: it is highly recommended that implementors design the `Metric` data type _based on_ the [Data Model](./data-model.md), rather than directly use the data types generated from the [proto files](https://github.com/open-telemetry/opentelemetry-proto/blob/main/opentelemetry/proto/metrics/v1/metrics.proto) (because the types generated from proto files are not guaranteed to be backward compatible). Returns: `ExportResult` `ExportResult` is one of: * `Success` - The batch has been successfully exported. For protocol exporters this typically means that the data is sent over the wire and delivered to the destination server. * `Failure` - exporting failed. The batch must be dropped. For example, this can happen when the batch contains bad data and cannot be serialized. Note: this result may be returned via an async mechanism or a callback, if that is idiomatic for the language implementation. ##### ForceFlush This is a hint to ensure that the export of any `Metrics` the exporter has received prior to the call to `ForceFlush` SHOULD be completed as soon as possible, preferably before returning from this method. `ForceFlush` SHOULD provide a way to let the caller know whether it succeeded, failed or timed out. `ForceFlush` SHOULD only be called in cases where it is absolutely necessary, such as when using some FaaS providers that may suspend the process after an invocation, but before the exporter exports the completed metrics. `ForceFlush` SHOULD complete or abort within some timeout. `ForceFlush` can be implemented as a blocking API or an asynchronous API which notifies the caller via a callback or an event. [OpenTelemetry SDK](../overview.md#sdk) authors MAY decide if they want to make the flush timeout configurable. ##### Shutdown Shuts down the exporter. Called when SDK is shut down. This is an opportunity for exporter to do any cleanup required. Shutdown SHOULD be called only once for each `MetricExporter` instance. After the call to `Shutdown` subsequent calls to `Export` are not allowed and should return a Failure result. `Shutdown` SHOULD NOT block indefinitely (e.g. if it attempts to flush the data and the destination is unavailable). [OpenTelemetry SDK](../overview.md#sdk) authors MAY decide if they want to make the shutdown timeout configurable. ### Pull Metric Exporter Pull Metric Exporter reacts to the metrics scrapers and reports the data passively. This pattern has been widely adopted by [Prometheus](https://prometheus.io/). Unlike [Push Metric Exporter](#push-metric-exporter) which can send data on its own schedule, pull exporter can only send the data when it is being asked by the scraper, and `ForceFlush` would not make sense. Implementors MAY choose the best idiomatic design for their language. For example, they could generalize the [Push Metric Exporter interface](#push-metric-exporter) design and use that for consistency, they could model the pull exporter as [MetricReader](#metricreader), or they could design a completely different pull exporter interface. If the pull exporter is modeled as MetricReader, implementors MAY name the MetricExporter interface as PushMetricExporter to prevent naming confusion. The following diagram gives some examples on how `Pull Metric Exporter` can be modeled to interact with other components in the SDK: * Model the pull exporter as MetricReader ```text +-----------------+ +-----------------------------+ | | Metrics... | | | In-memory state +------------> PrometheusExporter (pull) +---> Another process (scraper) | | | (modeled as a MetricReader) | +-----------------+ | | +-----------------------------+ ``` * Use the same MetricExporter design for both push and pull exporters ```text +-----------------+ +-----------------------------+ | | Metrics... | | | In-memory state +------------> Exporting MetricReader | | | | | +-----------------+ | +-----------------------+ | | | | | | | MetricExporter (pull) +------> Another process (scraper) | | | | | +-----------------------+ | | | +-----------------------------+ ``` ## MetricProducer **Status**: [Stable](../document-status.md) except where otherwise specified `MetricProducer` defines the interface which bridges to third-party metric sources MUST implement, so they can be plugged into an OpenTelemetry [MetricReader](#metricreader) as a source of aggregated metric data. The SDK's in-memory state MAY implement the `MetricProducer` interface for convenience. `MetricProducer` implementations SHOULD accept configuration for the `AggregationTemporality` of produced metrics. SDK authors MAY provide utility libraries to facilitate conversion between delta and cumulative temporalities. ```text +-----------------+ +--------------+ | | Metrics... | | | In-memory state +------------> MetricReader | | | | | +-----------------+ | | | | +-----------------+ | | | | Metrics... | | | MetricProducer +------------> | | | | | +-----------------+ +--------------+ ``` When new OpenTelemetry integrations are added, the API is the preferred integration point. The `MetricProducer` is only meant for integrations that bridge pre-processed data. ### Interface Definition A `MetricProducer` MUST support the following functions: #### Produce batch `Produce` provides metrics from the MetricProducer to the caller. `Produce` MUST return a batch of [Metric Points](./data-model.md#metric-points), filtered by the optional `metricFilter` parameter. Implementation SHOULD use the filter as early as possible to gain as much performance gain possible (memory allocation, internal metric fetching, etc). If the batch of [Metric Points](./data-model.md#metric-points) includes resource information, `Produce` SHOULD require a resource as a parameter. `Produce` does not have any other required parameters, however, [OpenTelemetry SDK](../overview.md#sdk) authors MAY choose to add required or optional parameters (e.g. timeout). `Produce` SHOULD provide a way to let the caller know whether it succeeded, failed or timed out. When the `Produce` operation fails, the `MetricProducer` MAY return successfully collected results and a failed reasons list to the caller. If a batch of [Metric Points](./data-model.md#metric-points) can include [`InstrumentationScope`](../glossary.md#instrumentation-scope) information, `Produce` SHOULD include a single InstrumentationScope which identifies the `MetricProducer`. **Parameters:** **Status**: [Development](../document-status.md) `metricFilter`: An optional [MetricFilter](#metricfilter). ## MetricFilter **Status**: [Development](../document-status.md) `MetricFilter` defines the interface which enables the [MetricReader](#metricreader)'s registered [MetricProducers](#metricproducer) or the SDK's [MetricProducer](#metricproducer) to filter aggregated data points ([Metric Points](./data-model.md#metric-points)) inside its `Produce` operation. The filtering is done at the [MetricProducer](#metricproducer) for performance reasons. The `MetricFilter` allows filtering an entire metric stream - dropping or allowing all its attribute sets - by its `TestMetric` operation, which accepts the metric stream information (scope, name, kind and unit) and returns an enumeration: `Accept`, `Drop` or `Accept_Partial`. If the latter returned, the `TestAttributes` operation is to be called per attribute set of that metric stream, returning an enumeration determining if the data point for that (metric stream, attributes) pair is to be allowed in the result of the [MetricProducer](#metricproducer) `Produce` operation. ### Interface Definition A `MetricFilter` MUST support the following functions: #### TestMetric This operation is called once for every metric stream, in each [MetricProducer](#metricproducer) `Produce` operation. **Parameters:** - `instrumentationScope`: the metric stream instrumentation scope - `name`: the name of the metric stream - `kind`: the metric stream [kind](./data-model.md#point-kinds) - `unit`: the metric stream unit Returns: `MetricFilterResult` `MetricFilterResult` is one of: * `Accept` - All attributes of the given metric stream are allowed (not to be filtered). This provides a "short-circuit" as there is no need to call `TestAttributes` operation for each attribute set. * `Drop` - All attributes of the given metric stream are NOT allowed (filtered out - dropped). This provides a "short-circuit" as there is no need to call `TestAttributes` operation for each attribute set, and no need to collect those data points be it synchronous or asynchronous: e.g. the callback for this given instrument does not need to be invoked. * `Accept_Partial` - Some attributes are allowed and some aren't, hence `TestAttributes` operation must be called for each attribute set of that instrument. #### TestAttributes An operation which determines for a given metric stream and attribute set if it should be allowed or filtered out. This operation should only be called if `TestMetric` operation returned `Accept_Partial` for the given metric stream arguments (`instrumentationScope`, `name`, `kind`, `unit`). **Parameters:** - `instrumentationScope`: the metric stream instrumentation scope - `name`: the name of the metric stream - `kind`: the metric stream kind - `unit`: the metric stream unit - `attributes`: the attributes Returns: `AttributesFilterResult` `AttributesFilterResult` is one of: * `Accept` - This given `attributes` are allowed (not to be filtered). * `Drop` - This given `attributes` are NOT allowed (filtered out - dropped). ## Defaults and configuration The SDK MUST provide configuration according to the [SDK environment variables](../configuration/sdk-environment-variables.md) specification. ## Numerical limits handling The SDK MUST handle numerical limits in a graceful way according to [Error handling in OpenTelemetry](../error-handling.md). If the SDK receives float/double values from [Instruments](./api.md#instrument), it MUST handle all the possible values. For example, if the language runtime supports [IEEE 754](https://en.wikipedia.org/wiki/IEEE_754), the SDK needs to handle NaNs and Infinites. It is unspecified _how_ the SDK should handle the input limits. The SDK authors MAY leverage/follow the language runtime behavior for better performance, rather than perform a check on each value coming from the API. It is unspecified _how_ the SDK should handle the output limits (e.g. integer overflow). The SDK authors MAY rely on the language runtime behavior as long as errors/exceptions are taken care of. ## Compatibility requirements **Status**: [Stable](../document-status.md) All the metrics components SHOULD allow new methods to be added to existing components without introducing breaking changes. All the metrics SDK methods SHOULD allow optional parameter(s) to be added to existing methods without introducing breaking changes, if possible. ## Concurrency requirements **Status**: [Stable](../document-status.md) For languages which support concurrent execution the Metrics SDKs provide specific guarantees and safeties. **MeterProvider** - Meter creation, `ForceFlush` and `Shutdown` are safe to be called concurrently. **ExemplarReservoir** - all methods are safe to be called concurrently. **MetricReader** - `Collect`, `ForceFlush` (for periodic exporting MetricReader) and `Shutdown` are safe to be called concurrently. **MetricExporter** - `ForceFlush` and `Shutdown` are safe to be called concurrently. ## References - [OTEP0113 Integrate Exemplars with Metrics](../../oteps/metrics/0113-exemplars.md) - [OTEP0126 A Proposal For SDK Support for Configurable Batching and Aggregations (Basic Views)](../../oteps/metrics/0126-Configurable-Metric-Aggregations.md) - [OTEP0146 Scenarios for Metrics API/SDK Prototyping](../../oteps/metrics/0146-metrics-prototype-scenarios.md)