Overview

The ID Lock Z-wave module is a security enabled Z-wave Plus product that is able to use encrypted Z-wave Plus messages in order to communicate to other Z-wave Plus products enabled security.

The module is proprietary for the ID Lock 150 and also backwards compatible with the ID Lock 101. The ID Lock Z-wave module must be used in conjunction with a Security Enabled Z-wave Controller in order to fully utilize their full capability.

The ID Lock Z-wave module can be included and operated in any Z-wave network containing certified other Z-wave products regardless of manufacturer. The ID Lock Z-wave module does not support the Basic Set Command Class.


Inclusion Information

  1. Bring the controller as close as possible to the lock unit
  2. Set the controller to inclusion mode
  3. Push and hold KEY button on the inside panel on the lock until all keys on the outside light up and a audible signal is given.
  4. Release the KEY button on the inside panel
  5. Enter your Master PIN and press * 
  6. Click 2 and then *
  7. Click 5, don't press *
  8. The LED flashes blue when inclusion is in progress
  9. The inclusion may take some time as security is required

Exclusion Information

  1. Set the controller to Exclusion mode
  2. Push and hold KEY button on the inside panel on the lock until all keys on the outside light up and a audible signal is given.
  3. Release the KEY button on the inside panel
  4. Enter your Master PIN and press * 
  5. Click 2 and then *
  6. Click 5, don't press *
  7. The LED flashes blue when exclusion is in progress
]]>
Lock COMMAND_CLASS_DOOR_LOCK COMMAND_CLASS_ALARM;type=ACCESS_CONTROL COMMAND_CLASS_ALARM;type=EMERGENCY COMMAND_CLASS_ALARM;type=BURGLAR COMMAND_CLASS_ALARM COMMAND_CLASS_BATTERY ID Lock AS ID-150 0373 0003:0001 887 1 setup link

Overview

Auto lock Mode, Manual lock mode, Activate Away Mode, Deactivate Away Mode.

If value is 0x02 (Enable Away, Manual lock) and the door is unlocked value will be set to 0x00.

If value is 0x03 (Enable Away, Auto lock) and the door is unlocked value will be set to 0x01.

 Default Value: 1 (Disable Away/Auto Lock Mode)

]]>
1
Tell the lock which side your hinges are on 0 Set the Audio Volume Level of the Lock 5

Overview

With this configuration ID Lock can automatically relock the door if an already locked door gets unlocked, but remains unopened. This is avoided by deactivating relocking.

]]>
1

Overview

A configuration get command on this parameter returns the latest set parameter value (set by Z-wave).

This is a set only value, if changed locally on keypad these values are not changed on Z-wave module. Value 5, 6 and 7 are for future use on door lock.

]]>
0

Overview

This configuration is only accepted by configuration get command

It is a read only parameter. Default value depends on the door lock model type.

101 = ID Lock 101

150 = ID Lock 150

]]>
0

Overview

Notification Reports are sent out unsolicated to device included in the association group.

]]>
5
true