{ "$schema": "http://json-schema.org/schema#", "$schemaVersion": "0.0.1", "$id": "https://smart-data-models.github.io/dataModels.CIMEnergyClasses/GovHydroIEEE2/schema.json", "title": " Smart Data Models - GovHydroIEEE2", "description": "Adapted from CIM data models. IEEE hydro turbine governor model represents plants with straightforward penstock configurations and hydraulic-dashpot governors. Ref", "type": "object", "allOf": [ { "$ref": "https://smart-data-models.github.io/data-models/common-schema.json#/definitions/GSMA-Commons" }, { "$ref": "https://smart-data-models.github.io/data-models/common-schema.json#/definitions/Location-Commons" }, { "properties": { "type": { "type": "string", "enum": [ "GovHydroIEEE2" ], "description": "Property. NGSI type. It has to be GovHydroIEEE2" }, "aturb": { "description": "Property. Model:'https://schema.org/Number'. Turbine numerator multiplier (Aturb). Typical Value = -1. Default: 0.0", "type": "number" }, "bturb": { "description": "Property. Model:'https://schema.org/Number'. Turbine denominator multiplier (Bturb). Typical Value = 0.5. Default: 0.0", "type": "number" }, "gv1": { "description": "Property. Model:'https://schema.org/Number'. Nonlinear gain point 1, PU gv (Gv1). Typical Value = 0. Default: 0.0", "type": "number" }, "gv2": { "description": "Property. Model:'https://schema.org/Number'. Nonlinear gain point 2, PU gv (Gv2). Typical Value = 0. Default: 0.0", "type": "number" }, "gv3": { "description": "Property. Model:'https://schema.org/Number'. Nonlinear gain point 3, PU gv (Gv3). Typical Value = 0. Default: 0.0", "type": "number" }, "gv4": { "description": "Property. Model:'https://schema.org/Number'. Nonlinear gain point 4, PU gv (Gv4). Typical Value = 0. Default: 0.0", "type": "number" }, "gv5": { "description": "Property. Model:'https://schema.org/Number'. Nonlinear gain point 5, PU gv (Gv5). Typical Value = 0. Default: 0.0", "type": "number" }, "gv6": { "description": "Property. Model:'https://schema.org/Number'. Nonlinear gain point 6, PU gv (Gv6). Typical Value = 0. Default: 0.0", "type": "number" }, "kturb": { "description": "Property. Model:'https://schema.org/Number'. Turbine gain (Kturb). Typical Value = 1. Default: 0.0", "type": "number" }, "mwbase": { "description": "Property. Model:'https://schema.org/Number'. Base for power values (MWbase) (> 0). Unit = MW. Default: 0.0", "type": "number" }, "pgv1": { "description": "Property. Model:'https://schema.org/Number'. Nonlinear gain point 1, PU power (Pgv1). Typical Value = 0. Default: 0.0", "type": "number" }, "pgv2": { "description": "Property. Model:'https://schema.org/Number'. Nonlinear gain point 2, PU power (Pgv2). Typical Value = 0. Default: 0.0", "type": "number" }, "pgv3": { "description": "Property. Model:'https://schema.org/Number'. Nonlinear gain point 3, PU power (Pgv3). Typical Value = 0. Default: 0.0", "type": "number" }, "pgv4": { "description": "Property. Model:'https://schema.org/Number'. Nonlinear gain point 4, PU power (Pgv4). Typical Value = 0. Default: 0.0", "type": "number" }, "pgv5": { "description": "Property. Model:'https://schema.org/Number'. Nonlinear gain point 5, PU power (Pgv5). Typical Value = 0. Default: 0.0", "type": "number" }, "pgv6": { "description": "Property. Model:'https://schema.org/Number'. Nonlinear gain point 6, PU power (Pgv6). Typical Value = 0. Default: 0.0", "type": "number" }, "pmax": { "description": "Property. Model:'https://schema.org/Number'. Maximum gate opening (Pmax). Typical Value = 1. Default: 0.0", "type": "number" }, "pmin": { "description": "Property. Model:'https://schema.org/Number'. Minimum gate opening (Pmin). Typical Value = 0. Default: 0.0", "type": "number" }, "rperm": { "description": "Property. Model:'https://schema.org/Number'. Permanent droop (Rperm). Typical Value = 0.05. Default: 0.0", "type": "number" }, "rtemp": { "description": "Property. Model:'https://schema.org/Number'. Temporary droop (Rtemp). Typical Value = 0.5. Default: 0.0", "type": "number" }, "tg": { "description": "Property. Model:'https://schema.org/Number'. Gate servo time constant (Tg). Typical Value = 0.5. Default: 0", "type": "number" }, "tp": { "description": "Property. Model:'https://schema.org/Number'. Pilot servo valve time constant (Tp). Typical Value = 0.03. Default: 0", "type": "number" }, "tr": { "description": "Property. Model:'https://schema.org/Number'. Dashpot time constant (Tr). Typical Value = 12. Default: 0", "type": "number" }, "tw": { "description": "Property. Model:'https://schema.org/Number'. Water inertia time constant (Tw). Typical Value = 2. Default: 0", "type": "number" }, "uc": { "description": "Property. Model:'https://schema.org/Number'. Maximum gate closing velocity (Uc) (<0). Typical Value = -0.1. Default: 0.0", "type": "number" }, "uo": { "description": "Property. Model:'https://schema.org/Number'. Maximum gate opening velocity (Uo). Unit = PU/sec. Typical Value = 0.1. Default: 0.0", "type": "number" } } } ] }