{ "$schema": "http://json-schema.org/schema#", "$schemaVersion": "0.0.1", "$id": "https://smart-data-models.github.io/dataModels.CIMEnergyClasses/GovHydroWEH/schema.json", "title": " Smart Data Models - GovHydroWEH", "description": "Adapted from CIM data models. Woodward Electric Hydro Governor Model.", "type": "object", "allOf": [ { "$ref": "https://smart-data-models.github.io/data-models/common-schema.json#/definitions/GSMA-Commons" }, { "$ref": "https://smart-data-models.github.io/data-models/common-schema.json#/definitions/Location-Commons" }, { "properties": { "type": { "type": "string", "enum": [ "GovHydroWEH" ], "description": "Property. NGSI type. It has to be GovHydroWEH" }, "db": { "description": "Property. Model:'https://schema.org/Number'. Speed Dead Band (db). Default: 0.0", "type": "number" }, "dicn": { "description": "Property. Model:'https://schema.org/Number'. Value to allow the integral controller to advance beyond the gate limits (Dicn). Default: 0.0", "type": "number" }, "dpv": { "description": "Property. Model:'https://schema.org/Number'. Value to allow the Pilot valve controller to advance beyond the gate limits (Dpv). Default: 0.0", "type": "number" }, "dturb": { "description": "Property. Model:'https://schema.org/Number'. Turbine damping factor (Dturb). Unit = delta P (PU of MWbase) / delta speed (PU). Default: 0.0", "type": "number" }, "feedbackSignal": { "description": "Property. Model:'https://schema.org/Number'. Feedback signal selection (Sw). true = PID Output (if R-Perm-Gate=droop and R-Perm-Pe=0) false = Electrical Power (if R-Perm-Gate=0 and R-Perm-Pe=droop) or false = Gate Position (if R-Perm-Gate=droop and R-Perm-Pe=0). Default: False", "type": "number" }, "fl1": { "description": "Property. Model:'https://schema.org/Number'. Flow Gate 1 (Fl1). Flow value for gate position point 1 for lookup table representing water flow through the turbine as a function of gate position to produce steady state flow. Default: 0.0", "type": "number" }, "fl2": { "description": "Property. Model:'https://schema.org/Number'. Flow Gate 2 (Fl2). Flow value for gate position point 2 for lookup table representing water flow through the turbine as a function of gate position to produce steady state flow. Default: 0.0", "type": "number" }, "fl3": { "description": "Property. Model:'https://schema.org/Number'. Flow Gate 3 (Fl3). Flow value for gate position point 3 for lookup table representing water flow through the turbine as a function of gate position to produce steady state flow. Default: 0.0", "type": "number" }, "fl4": { "description": "Property. Model:'https://schema.org/Number'. Flow Gate 4 (Fl4). Flow value for gate position point 4 for lookup table representing water flow through the turbine as a function of gate position to produce steady state flow. Default: 0.0", "type": "number" }, "fl5": { "description": "Property. Model:'https://schema.org/Number'. Flow Gate 5 (Fl5). Flow value for gate position point 5 for lookup table representing water flow through the turbine as a function of gate position to produce steady state flow. Default: 0.0", "type": "number" }, "fp1": { "description": "Property. Model:'https://schema.org/Number'. Flow P1 (Fp1). Turbine Flow value for point 1 for lookup table representing per unit mechanical power on machine MVA rating as a function of turbine flow. Default: 0.0", "type": "number" }, "fp10": { "description": "Property. Model:'https://schema.org/Number'. Flow P10 (Fp10). Turbine Flow value for point 10 for lookup table representing per unit mechanical power on machine MVA rating as a function of turbine flow. Default: 0.0", "type": "number" }, "fp2": { "description": "Property. Model:'https://schema.org/Number'. Flow P2 (Fp2). Turbine Flow value for point 2 for lookup table representing per unit mechanical power on machine MVA rating as a function of turbine flow. Default: 0.0", "type": "number" }, "fp3": { "description": "Property. Model:'https://schema.org/Number'. Flow P3 (Fp3). Turbine Flow value for point 3 for lookup table representing per unit mechanical power on machine MVA rating as a function of turbine flow. Default: 0.0", "type": "number" }, "fp4": { "description": "Property. Model:'https://schema.org/Number'. Flow P4 (Fp4). Turbine Flow value for point 4 for lookup table representing per unit mechanical power on machine MVA rating as a function of turbine flow. Default: 0.0", "type": "number" }, "fp5": { "description": "Property. Model:'https://schema.org/Number'. Flow P5 (Fp5). Turbine Flow value for point 5 for lookup table representing per unit mechanical power on machine MVA rating as a function of turbine flow. Default: 0.0", "type": "number" }, "fp6": { "description": "Property. Model:'https://schema.org/Number'. Flow P6 (Fp6). Turbine Flow value for point 6 for lookup table representing per unit mechanical power on machine MVA rating as a function of turbine flow. Default: 0.0", "type": "number" }, "fp7": { "description": "Property. Model:'https://schema.org/Number'. Flow P7 (Fp7). Turbine Flow value for point 7 for lookup table representing per unit mechanical power on machine MVA rating as a function of turbine flow. Default: 0.0", "type": "number" }, "fp8": { "description": "Property. Model:'https://schema.org/Number'. Flow P8 (Fp8). Turbine Flow value for point 8 for lookup table representing per unit mechanical power on machine MVA rating as a function of turbine flow. Default: 0.0", "type": "number" }, "fp9": { "description": "Property. Model:'https://schema.org/Number'. Flow P9 (Fp9). Turbine Flow value for point 9 for lookup table representing per unit mechanical power on machine MVA rating as a function of turbine flow. Default: 0.0", "type": "number" }, "gmax": { "description": "Property. Model:'https://schema.org/Number'. Maximum Gate Position (Gmax). Default: 0.0", "type": "number" }, "gmin": { "description": "Property. Model:'https://schema.org/Number'. Minimum Gate Position (Gmin). Default: 0.0", "type": "number" }, "gtmxcl": { "description": "Property. Model:'https://schema.org/Number'. Maximum gate closing rate (Gtmxcl). Default: 0.0", "type": "number" }, "gtmxop": { "description": "Property. Model:'https://schema.org/Number'. Maximum gate opening rate (Gtmxop). Default: 0.0", "type": "number" }, "gv1": { "description": "Property. Model:'https://schema.org/Number'. Gate 1 (Gv1). Gate Position value for point 1 for lookup table representing water flow through the turbine as a function of gate position to produce steady state flow. Default: 0.0", "type": "number" }, "gv2": { "description": "Property. Model:'https://schema.org/Number'. Gate 2 (Gv2). Gate Position value for point 2 for lookup table representing water flow through the turbine as a function of gate position to produce steady state flow. Default: 0.0", "type": "number" }, "gv3": { "description": "Property. Model:'https://schema.org/Number'. Gate 3 (Gv3). Gate Position value for point 3 for lookup table representing water flow through the turbine as a function of gate position to produce steady state flow. Default: 0.0", "type": "number" }, "gv4": { "description": "Property. Model:'https://schema.org/Number'. Gate 4 (Gv4). Gate Position value for point 4 for lookup table representing water flow through the turbine as a function of gate position to produce steady state flow. Default: 0.0", "type": "number" }, "gv5": { "description": "Property. Model:'https://schema.org/Number'. Gate 5 (Gv5). Gate Position value for point 5 for lookup table representing water flow through the turbine as a function of gate position to produce steady state flow. Default: 0.0", "type": "number" }, "kd": { "description": "Property. Model:'https://schema.org/Number'. Derivative controller derivative gain (Kd). Default: 0.0", "type": "number" }, "ki": { "description": "Property. Model:'https://schema.org/Number'. Derivative controller Integral gain (Ki). Default: 0.0", "type": "number" }, "kp": { "description": "Property. Model:'https://schema.org/Number'. Derivative control gain (Kp). Default: 0.0", "type": "number" }, "mwbase": { "description": "Property. Model:'https://schema.org/Number'. Base for power values (MWbase) (>0). Unit = MW. Default: 0.0", "type": "number" }, "pmss1": { "description": "Property. Model:'https://schema.org/Number'. Pmss Flow P1 (Pmss1). Mechanical Power output Pmss for Turbine Flow point 1 for lookup table representing per unit mechanical power on machine MVA rating as a function of turbine flow. Default: 0.0", "type": "number" }, "pmss10": { "description": "Property. Model:'https://schema.org/Number'. Pmss Flow P10 (Pmss10). Mechanical Power output Pmss for Turbine Flow point 10 for lookup table representing per unit mechanical power on machine MVA rating as a function of turbine flow. Default: 0.0", "type": "number" }, "pmss2": { "description": "Property. Model:'https://schema.org/Number'. Pmss Flow P2 (Pmss2). Mechanical Power output Pmss for Turbine Flow point 2 for lookup table representing per unit mechanical power on machine MVA rating as a function of turbine flow. Default: 0.0", "type": "number" }, "pmss3": { "description": "Property. Model:'https://schema.org/Number'. Pmss Flow P3 (Pmss3). Mechanical Power output Pmss for Turbine Flow point 3 for lookup table representing per unit mechanical power on machine MVA rating as a function of turbine flow. Default: 0.0", "type": "number" }, "pmss4": { "description": "Property. Model:'https://schema.org/Number'. Pmss Flow P4 (Pmss4). Mechanical Power output Pmss for Turbine Flow point 4 for lookup table representing per unit mechanical power on machine MVA rating as a function of turbine flow. Default: 0.0", "type": "number" }, "pmss5": { "description": "Property. Model:'https://schema.org/Number'. Pmss Flow P5 (Pmss5). Mechanical Power output Pmss for Turbine Flow point 5 for lookup table representing per unit mechanical power on machine MVA rating as a function of turbine flow. Default: 0.0", "type": "number" }, "pmss6": { "description": "Property. Model:'https://schema.org/Number'. Pmss Flow P6 (Pmss6). Mechanical Power output Pmss for Turbine Flow point 6 for lookup table representing per unit mechanical power on machine MVA rating as a function of turbine flow. Default: 0.0", "type": "number" }, "pmss7": { "description": "Property. Model:'https://schema.org/Number'. Pmss Flow P7 (Pmss7). Mechanical Power output Pmss for Turbine Flow point 7 for lookup table representing per unit mechanical power on machine MVA rating as a function of turbine flow. Default: 0.0", "type": "number" }, "pmss8": { "description": "Property. Model:'https://schema.org/Number'. Pmss Flow P8 (Pmss8). Mechanical Power output Pmss for Turbine Flow point 8 for lookup table representing per unit mechanical power on machine MVA rating as a function of turbine flow. Default: 0.0", "type": "number" }, "pmss9": { "description": "Property. Model:'https://schema.org/Number'. Pmss Flow P9 (Pmss9). Mechanical Power output Pmss for Turbine Flow point 9 for lookup table representing per unit mechanical power on machine MVA rating as a function of turbine flow. Default: 0.0", "type": "number" }, "rpg": { "description": "Property. Model:'https://schema.org/Number'. Permanent droop for governor output feedback (R-Perm-Gate). Default: 0.0", "type": "number" }, "rpp": { "description": "Property. Model:'https://schema.org/Number'. Permanent droop for electrical power feedback (R-Perm-Pe). Default: 0.0", "type": "number" }, "td": { "description": "Property. Model:'https://schema.org/Number'. Derivative controller time constant to limit the derivative characteristic beyond a breakdown frequency to avoid amplification of high-frequency noise (Td). Default: 0", "type": "number" }, "tdv": { "description": "Property. Model:'https://schema.org/Number'. Distributive Valve time lag time constant (Tdv). Default: 0", "type": "number" }, "tg": { "description": "Property. Model:'https://schema.org/Number'. Value to allow the Distribution valve controller to advance beyond the gate movement rate limit (Tg). Default: 0", "type": "number" }, "tp": { "description": "Property. Model:'https://schema.org/Number'. Pilot Valve time lag time constant (Tp). Default: 0", "type": "number" }, "tpe": { "description": "Property. Model:'https://schema.org/Number'. Electrical power droop time constant (Tpe). Default: 0", "type": "number" }, "tw": { "description": "Property. Model:'https://schema.org/Number'. Water inertia time constant (Tw) (>0). Default: 0", "type": "number" } } } ] }