{ "$schema": "http://json-schema.org/schema#", "$schemaVersion": "0.0.1", "$id": "https://smart-data-models.github.io/dataModels.CIMEnergyClasses/TurbLCFB1/schema.json", "title": " Smart Data Models - TurbLCFB1", "description": "Adapted from CIM data models. Turbine Load Controller model developed in the WECC. This model represents a supervisory turbine load controller that acts to maintain turbine power at a set value by continuous adjustment of the turbine governor speed-load reference. This model is intended to represent slow reset 'outer loop' controllers managing the action of the turbine governor.", "type": "object", "allOf": [ { "$ref": "https://smart-data-models.github.io/data-models/common-schema.json#/definitions/GSMA-Commons" }, { "$ref": "https://smart-data-models.github.io/data-models/common-schema.json#/definitions/Location-Commons" }, { "properties": { "type": { "type": "string", "enum": [ "TurbLCFB1" ], "description": "Property. NGSI type. It has to be TurbLCFB1" }, "db": { "description": "Property. Model:'https://schema.org/Number'. Controller dead band (db). Typical Value = 0. Default: 0.0", "type": "number" }, "emax": { "description": "Property. Model:'https://schema.org/Number'. Maximum control error (Emax) (note 4). Typical Value = 0.02. Default: 0.0", "type": "number" }, "fb": { "description": "Property. Model:'https://schema.org/Number'. Frequency bias gain (Fb). Typical Value = 0. Default: 0.0", "type": "number" }, "fbf": { "description": "Property. Model:'https://schema.org/Number'. Frequency bias flag (Fbf). true = enable frequency bias false = disable frequency bias. Typical Value = false. Default: False", "type": "number" }, "irmax": { "description": "Property. Model:'https://schema.org/Number'. Maximum turbine speed/load reference bias (Irmax) (note 3). Typical Value = 0. Default: 0.0", "type": "number" }, "ki": { "description": "Property. Model:'https://schema.org/Number'. Integral gain (Ki). Typical Value = 0. Default: 0.0", "type": "number" }, "kp": { "description": "Property. Model:'https://schema.org/Number'. Proportional gain (Kp). Typical Value = 0. Default: 0.0", "type": "number" }, "mwbase": { "description": "Property. Model:'https://schema.org/Number'. Base for power values (MWbase) (>0). Unit = MW. Default: 0.0", "type": "number" }, "pbf": { "description": "Property. Model:'https://schema.org/Number'. Power controller flag (Pbf). true = enable load controller false = disable load controller. Typical Value = false. Default: False", "type": "number" }, "pmwset": { "description": "Property. Model:'https://schema.org/Number'. Power controller setpoint (Pmwset) (note 1). Unit = MW. Typical Value = 0. Default: 0.0", "type": "number" }, "speedReferenceGovernor": { "description": "Property. Model:'https://schema.org/Number'. Type of turbine governor reference (Type). true = speed reference governor false = load reference governor. Typical Value = true. Default: False", "type": "number" }, "tpelec": { "description": "Property. Model:'https://schema.org/Number'. Power transducer time constant (Tpelec). Typical Value = 0. Default: 0", "type": "number" } } } ] }