{ "$schema": "http://json-schema.org/schema#", "$schemaVersion": "0.0.1", "$id": "https://smart-data-models.github.io/dataModels.CIMEnergyClasses/GovHydroFrancis/schema.json", "title": " Smart Data Models - GovHydroFrancis", "description": "Adapted from CIM data models. Detailed hydro unit - Francis model. This model can be used to represent three types of governors. A schematic of the hydraulic system of detailed hydro unit models, like Francis and Pelton, is provided in the DetailedHydroModelHydraulicSystem diagram.", "type": "object", "allOf": [ { "$ref": "https://smart-data-models.github.io/data-models/common-schema.json#/definitions/GSMA-Commons" }, { "$ref": "https://smart-data-models.github.io/data-models/common-schema.json#/definitions/Location-Commons" }, { "properties": { "type": { "type": "string", "enum": [ "GovHydroFrancis" ], "description": "Property. NGSI type. It has to be GovHydroFrancis" }, "am": { "description": "Property. Model:'https://schema.org/Number'. Opening section S at the maximum efficiency (Am). Typical Value = 0.7. Default: 0.0", "type": "number" }, "av0": { "description": "Property. Model:'https://schema.org/Number'. Area of the surge tank (A). Unit = m. Typical Value = 30. Default: 0.0", "type": "number" }, "av1": { "description": "Property. Model:'https://schema.org/Number'. Area of the compensation tank (A). Unit = m. Typical Value = 700. Default: 0.0", "type": "number" }, "bp": { "description": "Property. Model:'https://schema.org/Number'. Droop (Bp). Typical Value = 0.05. Default: 0.0", "type": "number" }, "db1": { "description": "Property. Model:'https://schema.org/Number'. Intentional dead-band width (DB1). Unit = Hz. Typical Value = 0. Default: 0.0", "type": "number" }, "etamax": { "description": "Property. Model:'https://schema.org/Number'. Maximum efficiency (EtaMax). Typical Value = 1.05. Default: 0.0", "type": "number" }, "governorControl": { "description": "Property. Model:'https://schema.org/Number'. Governor control flag (Cflag). Typical Value = mechanicHydrolicTachoAccelerator. Default: None", "type": "number" }, "h1": { "description": "Property. Model:'https://schema.org/Number'. Head of compensation chamber water level with respect to the level of penstock (H). Unit = m. Typical Value = 4. Default: 0.0", "type": "number" }, "h2": { "description": "Property. Model:'https://schema.org/Number'. Head of surge tank water level with respect to the level of penstock (H). Unit = m. Typical Value = 40. Default: 0.0", "type": "number" }, "hn": { "description": "Property. Model:'https://schema.org/Number'. Rated hydraulic head (H). Unit = m. Typical Value = 250. Default: 0.0", "type": "number" }, "kc": { "description": "Property. Model:'https://schema.org/Number'. Penstock loss coefficient (due to friction) (Kc). Typical Value = 0.025. Default: 0.0", "type": "number" }, "kg": { "description": "Property. Model:'https://schema.org/Number'. Water tunnel and surge chamber loss coefficient (due to friction) (Kg). Typical Value = 0.025. Default: 0.0", "type": "number" }, "kt": { "description": "Property. Model:'https://schema.org/Number'. Washout gain (Kt). Typical Value = 0.25. Default: 0.0", "type": "number" }, "qc0": { "description": "Property. Model:'https://schema.org/Number'. No-load turbine flow at nominal head (Qc0). Typical Value = 0.21. Default: 0.0", "type": "number" }, "qn": { "description": "Property. Model:'https://schema.org/Number'. Rated flow (Q). Unit = m/s. Typical Value = 40. Default: 0.0", "type": "number" }, "ta": { "description": "Property. Model:'https://schema.org/Number'. Derivative gain (Ta). Typical Value = 3. Default: 0", "type": "number" }, "td": { "description": "Property. Model:'https://schema.org/Number'. Washout time constant (Td). Typical Value = 3. Default: 0", "type": "number" }, "ts": { "description": "Property. Model:'https://schema.org/Number'. Gate servo time constant (Ts). Typical Value = 0.5. Default: 0", "type": "number" }, "twnc": { "description": "Property. Model:'https://schema.org/Number'. Water inertia time constant (Twnc). Typical Value = 1. Default: 0", "type": "number" }, "twng": { "description": "Property. Model:'https://schema.org/Number'. Water tunnel and surge chamber inertia time constant (Twng). Typical Value = 3. Default: 0", "type": "number" }, "tx": { "description": "Property. Model:'https://schema.org/Number'. Derivative feedback gain (Tx). Typical Value = 1. Default: 0", "type": "number" }, "va": { "description": "Property. Model:'https://schema.org/Number'. Maximum gate opening velocity (Va). Unit = PU/sec. Typical Value = 0.011. Default: 0.0", "type": "number" }, "valvmax": { "description": "Property. Model:'https://schema.org/Number'. Maximum gate opening (ValvMax). Typical Value = 1. Default: 0.0", "type": "number" }, "valvmin": { "description": "Property. Model:'https://schema.org/Number'. Minimum gate opening (ValvMin). Typical Value = 0. Default: 0.0", "type": "number" }, "vc": { "description": "Property. Model:'https://schema.org/Number'. Maximum gate closing velocity (Vc). Unit = PU/sec. Typical Value = -0.011. Default: 0.0", "type": "number" }, "waterTunnelSurgeChamberSimulation": { "description": "Property. Model:'https://schema.org/Number'. Water tunnel and surge chamber simulation (Tflag). true = enable of water tunnel and surge chamber simulation false = inhibit of water tunnel and surge chamber simulation. Typical Value = false. Default: False", "type": "number" }, "zsfc": { "description": "Property. Model:'https://schema.org/Number'. Head of upper water level with respect to the level of penstock (Zsfc). Unit = m. Typical Value = 25. Default: 0.0", "type": "number" } } } ] }