{ "$schema": "http://json-schema.org/schema#", "$schemaVersion": "0.0.1", "$id": "https://smart-data-models.github.io/dataModels.CIMEnergyClasses/GovHydroDD/schema.json", "title": " Smart Data Models - GovHydroDD", "description": "Adapted from CIM data models. Double derivative hydro governor and turbine.", "type": "object", "allOf": [ { "$ref": "https://smart-data-models.github.io/data-models/common-schema.json#/definitions/GSMA-Commons" }, { "$ref": "https://smart-data-models.github.io/data-models/common-schema.json#/definitions/Location-Commons" }, { "properties": { "type": { "type": "string", "enum": [ "GovHydroDD" ], "description": "Property. NGSI type. It has to be GovHydroDD" }, "aturb": { "description": "Property. Model:'https://schema.org/Number'. Turbine numerator multiplier (Aturb) (note 3). Typical Value = -1. Default: 0.0", "type": "number" }, "bturb": { "description": "Property. Model:'https://schema.org/Number'. Turbine denominator multiplier (Bturb) (note 3). Typical Value = 0.5. Default: 0.0", "type": "number" }, "db1": { "description": "Property. Model:'https://schema.org/Number'. Intentional dead-band width (db1). Unit = Hz. Typical Value = 0. Default: 0.0", "type": "number" }, "db2": { "description": "Property. Model:'https://schema.org/Number'. Unintentional dead-band (db2). Unit = MW. Typical Value = 0. Default: 0.0", "type": "number" }, "eps": { "description": "Property. Model:'https://schema.org/Number'. Intentional db hysteresis (eps). Unit = Hz. Typical Value = 0. Default: 0.0", "type": "number" }, "gmax": { "description": "Property. Model:'https://schema.org/Number'. Maximum gate opening (Gmax). Typical Value = 0. Default: 0.0", "type": "number" }, "gmin": { "description": "Property. Model:'https://schema.org/Number'. Minimum gate opening (Gmin). Typical Value = 0. Default: 0.0", "type": "number" }, "gv1": { "description": "Property. Model:'https://schema.org/Number'. Nonlinear gain point 1, PU gv (Gv1). Typical Value = 0. Default: 0.0", "type": "number" }, "gv2": { "description": "Property. Model:'https://schema.org/Number'. Nonlinear gain point 2, PU gv (Gv2). Typical Value = 0. Default: 0.0", "type": "number" }, "gv3": { "description": "Property. Model:'https://schema.org/Number'. Nonlinear gain point 3, PU gv (Gv3). Typical Value = 0. Default: 0.0", "type": "number" }, "gv4": { "description": "Property. Model:'https://schema.org/Number'. Nonlinear gain point 4, PU gv (Gv4). Typical Value = 0. Default: 0.0", "type": "number" }, "gv5": { "description": "Property. Model:'https://schema.org/Number'. Nonlinear gain point 5, PU gv (Gv5). Typical Value = 0. Default: 0.0", "type": "number" }, "gv6": { "description": "Property. Model:'https://schema.org/Number'. Nonlinear gain point 6, PU gv (Gv6). Typical Value = 0. Default: 0.0", "type": "number" }, "inputSignal": { "description": "Property. Model:'https://schema.org/Number'. Input signal switch (Flag). true = Pe input is used false = feedback is received from CV. Flag is normally dependent on Tt. If Tf is zero, Flag is set to false. If Tf is not zero, Flag is set to true. Typical Value = true. Default: False", "type": "number" }, "k1": { "description": "Property. Model:'https://schema.org/Number'. Single derivative gain (K1). Typical Value = 3.6. Default: 0.0", "type": "number" }, "k2": { "description": "Property. Model:'https://schema.org/Number'. Double derivative gain (K2). Typical Value = 0.2. Default: 0.0", "type": "number" }, "kg": { "description": "Property. Model:'https://schema.org/Number'. Gate servo gain (Kg). Typical Value = 3. Default: 0.0", "type": "number" }, "ki": { "description": "Property. Model:'https://schema.org/Number'. Integral gain (Ki). Typical Value = 1. Default: 0.0", "type": "number" }, "mwbase": { "description": "Property. Model:'https://schema.org/Number'. Base for power values (MWbase) (>0). Unit = MW. Default: 0.0", "type": "number" }, "pgv1": { "description": "Property. Model:'https://schema.org/Number'. Nonlinear gain point 1, PU power (Pgv1). Typical Value = 0. Default: 0.0", "type": "number" }, "pgv2": { "description": "Property. Model:'https://schema.org/Number'. Nonlinear gain point 2, PU power (Pgv2). Typical Value = 0. Default: 0.0", "type": "number" }, "pgv3": { "description": "Property. Model:'https://schema.org/Number'. Nonlinear gain point 3, PU power (Pgv3). Typical Value = 0. Default: 0.0", "type": "number" }, "pgv4": { "description": "Property. Model:'https://schema.org/Number'. Nonlinear gain point 4, PU power (Pgv4). Typical Value = 0. Default: 0.0", "type": "number" }, "pgv5": { "description": "Property. Model:'https://schema.org/Number'. Nonlinear gain point 5, PU power (Pgv5). Typical Value = 0. Default: 0.0", "type": "number" }, "pgv6": { "description": "Property. Model:'https://schema.org/Number'. Nonlinear gain point 6, PU power (Pgv6). Typical Value = 0. Default: 0.0", "type": "number" }, "pmax": { "description": "Property. Model:'https://schema.org/Number'. Maximum gate opening, PU of MWbase (Pmax). Typical Value = 1. Default: 0.0", "type": "number" }, "pmin": { "description": "Property. Model:'https://schema.org/Number'. Minimum gate opening, PU of MWbase (Pmin). Typical Value = 0. Default: 0.0", "type": "number" }, "r": { "description": "Property. Model:'https://schema.org/Number'. Steady state droop (R). Typical Value = 0.05. Default: 0.0", "type": "number" }, "td": { "description": "Property. Model:'https://schema.org/Number'. Input filter time constant (Td). Typical Value = 0. Default: 0", "type": "number" }, "tf": { "description": "Property. Model:'https://schema.org/Number'. Washout time constant (Tf). Typical Value = 0.1. Default: 0", "type": "number" }, "tp": { "description": "Property. Model:'https://schema.org/Number'. Gate servo time constant (Tp). Typical Value = 0.35. Default: 0", "type": "number" }, "tt": { "description": "Property. Model:'https://schema.org/Number'. Power feedback time constant (Tt). Typical Value = 0.02. Default: 0", "type": "number" }, "tturb": { "description": "Property. Model:'https://schema.org/Number'. Turbine time constant (Tturb) (note 3). Typical Value = 0.8. Default: 0", "type": "number" }, "velcl": { "description": "Property. Model:'https://schema.org/Number'. Maximum gate closing velocity (Velcl). Unit = PU/sec. Typical Value = -0.14. Default: 0.0", "type": "number" }, "velop": { "description": "Property. Model:'https://schema.org/Number'. Maximum gate opening velocity (Velop). Unit = PU/sec. Typical Value = 0.09. Default: 0.0", "type": "number" } } } ] }