{ "$schema": "http://json-schema.org/schema#", "$schemaVersion": "0.0.1", "$id": "https://smart-data-models.github.io/dataModels.CIMEnergyClasses/ExcSK/schema.json", "title": " Smart Data Models - ExcSK", "description": "Adapted from CIM data models. Slovakian Excitation System Model. UEL and secondary voltage control are included in this model. When this model is used, there cannot be a separate underexcitation limiter or VAr controller model.", "type": "object", "allOf": [ { "$ref": "https://smart-data-models.github.io/data-models/common-schema.json#/definitions/GSMA-Commons" }, { "$ref": "https://smart-data-models.github.io/data-models/common-schema.json#/definitions/Location-Commons" }, { "properties": { "type": { "type": "string", "enum": [ "ExcSK" ], "description": "Property. NGSI type. It has to be ExcSK" }, "efdmax": { "description": "Property. Model:'https://schema.org/Number'. Field voltage clipping limit (Efdmax). Default: 0.0", "type": "number" }, "efdmin": { "description": "Property. Model:'https://schema.org/Number'. Field voltage clipping limit (Efdmin). Default: 0.0", "type": "number" }, "emax": { "description": "Property. Model:'https://schema.org/Number'. Maximum field voltage output (Emax). Typical Value = 20. Default: 0.0", "type": "number" }, "emin": { "description": "Property. Model:'https://schema.org/Number'. Minimum field voltage output (Emin). Typical Value = -20. Default: 0.0", "type": "number" }, "k": { "description": "Property. Model:'https://schema.org/Number'. Gain (K). Typical Value = 1. Default: 0.0", "type": "number" }, "k1": { "description": "Property. Model:'https://schema.org/Number'. Parameter of underexcitation limit (K1). Typical Value = 0.1364. Default: 0.0", "type": "number" }, "k2": { "description": "Property. Model:'https://schema.org/Number'. Parameter of underexcitation limit (K2). Typical Value = -0.3861. Default: 0.0", "type": "number" }, "kc": { "description": "Property. Model:'https://schema.org/Number'. PI controller gain (Kc). Typical Value = 70. Default: 0.0", "type": "number" }, "kce": { "description": "Property. Model:'https://schema.org/Number'. Rectifier regulation factor (Kce). Typical Value = 0. Default: 0.0", "type": "number" }, "kd": { "description": "Property. Model:'https://schema.org/Number'. Exciter internal reactance (Kd). Typical Value = 0. Default: 0.0", "type": "number" }, "kgob": { "description": "Property. Model:'https://schema.org/Number'. P controller gain (Kgob). Typical Value = 10. Default: 0.0", "type": "number" }, "kp": { "description": "Property. Model:'https://schema.org/Number'. PI controller gain (Kp). Typical Value = 1. Default: 0.0", "type": "number" }, "kqi": { "description": "Property. Model:'https://schema.org/Number'. PI controller gain of integral component (Kqi). Typical Value = 0. Default: 0.0", "type": "number" }, "kqob": { "description": "Property. Model:'https://schema.org/Number'. Rate of rise of the reactive power (Kqob). Default: 0.0", "type": "number" }, "kqp": { "description": "Property. Model:'https://schema.org/Number'. PI controller gain (Kqp). Typical Value = 0. Default: 0.0", "type": "number" }, "nq": { "description": "Property. Model:'https://schema.org/Number'. Dead band of reactive power (nq). Determines the range of sensitivity. Typical Value = 0.001. Default: 0.0", "type": "number" }, "qconoff": { "description": "Property. Model:'https://schema.org/Number'. Secondary voltage control state (Qc_on_off). true = secondary voltage control is ON false = secondary voltage control is OFF. Typical Value = false. Default: False", "type": "number" }, "qz": { "description": "Property. Model:'https://schema.org/Number'. Desired value (setpoint) of reactive power, manual setting (Qz). Default: 0.0", "type": "number" }, "remote": { "description": "Property. Model:'https://schema.org/Number'. Selector to apply automatic calculation in secondary controller model. true = automatic calculation is activated false = manual set is active; the use of desired value of reactive power (Qz) is required. Typical Value = true. Default: False", "type": "number" }, "sbase": { "description": "Property. Model:'https://schema.org/Number'. Apparent power of the unit (Sbase). Unit = MVA. Typical Value = 259. Default: 0.0", "type": "number" }, "tc": { "description": "Property. Model:'https://schema.org/Number'. PI controller phase lead time constant (Tc). Typical Value = 8. Default: 0", "type": "number" }, "te": { "description": "Property. Model:'https://schema.org/Number'. Time constant of gain block (Te). Typical Value = 0.1. Default: 0", "type": "number" }, "ti": { "description": "Property. Model:'https://schema.org/Number'. PI controller phase lead time constant (Ti). Typical Value = 2. Default: 0", "type": "number" }, "tp": { "description": "Property. Model:'https://schema.org/Number'. Time constant (Tp). Typical Value = 0.1. Default: 0", "type": "number" }, "tr": { "description": "Property. Model:'https://schema.org/Number'. Voltage transducer time constant (Tr). Typical Value = 0.01. Default: 0", "type": "number" }, "uimax": { "description": "Property. Model:'https://schema.org/Number'. Maximum error (Uimax). Typical Value = 10. Default: 0.0", "type": "number" }, "uimin": { "description": "Property. Model:'https://schema.org/Number'. Minimum error (UImin). Typical Value = -10. Default: 0.0", "type": "number" }, "urmax": { "description": "Property. Model:'https://schema.org/Number'. Maximum controller output (URmax). Typical Value = 10. Default: 0.0", "type": "number" }, "urmin": { "description": "Property. Model:'https://schema.org/Number'. Minimum controller output (URmin). Typical Value = -10. Default: 0.0", "type": "number" }, "vtmax": { "description": "Property. Model:'https://schema.org/Number'. Maximum terminal voltage input (Vtmax). Determines the range of voltage dead band. Typical Value = 1.05. Default: 0.0", "type": "number" }, "vtmin": { "description": "Property. Model:'https://schema.org/Number'. Minimum terminal voltage input (Vtmin). Determines the range of voltage dead band. Typical Value = 0.95. Default: 0.0", "type": "number" }, "yp": { "description": "Property. Model:'https://schema.org/Number'. Maximum output (Yp). Minimum output = 0. Typical Value = 1. Default: 0.0", "type": "number" } } } ] }