{ "$schema": "http://json-schema.org/schema#", "$schemaVersion": "0.0.1", "$id": "https://smart-data-models.github.io/dataModels.CIMEnergyClasses/ACDCConverter/schema.json", "title": " Smart Data Models - ACDCConverter", "description": "Adapted from CIM data models. A unit with valves for three phases, together with unit control equipment, essential protective and switching devices, DC storage capacitors, phase reactors and auxiliaries, if any, used for conversion.", "type": "object", "allOf": [ { "$ref": "https://smart-data-models.github.io/data-models/common-schema.json#/definitions/GSMA-Commons" }, { "$ref": "https://smart-data-models.github.io/data-models/common-schema.json#/definitions/Location-Commons" }, { "properties": { "type": { "type": "string", "enum": [ "ACDCConverter" ], "description": "Property. NGSI type. It has to be ACDCConverter" }, "DCTerminals": { "description": "Property. Model:'https://schema.org/Number'. Default: 'list'", "type": "number" }, "PccTerminal": { "description": "Property. Model:'https://schema.org/Number'. All converters` DC sides linked to this point of common coupling terminal. Default: None", "type": "number" }, "baseS": { "description": "Property. Model:'https://schema.org/Number'. Base apparent power of the converter pole. Default: 0.0", "type": "number" }, "idc": { "description": "Property. Model:'https://schema.org/Number'. Converter DC current, also called Id. Converter state variable, result from power flow. Default: 0.0", "type": "number" }, "idleLoss": { "description": "Property. Model:'https://schema.org/Number'. Active power loss in pole at no power transfer. Converter configuration data used in power flow. Default: 0.0", "type": "number" }, "maxUdc": { "description": "Property. Model:'https://schema.org/Number'. The maximum voltage on the DC side at which the converter should operate. Converter configuration data used in power flow. Default: 0.0", "type": "number" }, "minUdc": { "description": "Property. Model:'https://schema.org/Number'. Min allowed converter DC voltage. Converter configuration data used in power flow. Default: 0.0", "type": "number" }, "numberOfValves": { "description": "Property. Model:'https://schema.org/Number'. Number of valves in the converter. Used in loss calculations. Default: 0", "type": "number" }, "p": { "description": "Property. Model:'https://schema.org/Number'. Active power at the point of common coupling. Load sign convention is used, i.e. positive sign means flow out from a node. Starting value for a steady state solution in the case a simplified power flow model is used. Default: 0.0", "type": "number" }, "poleLossP": { "description": "Property. Model:'https://schema.org/Number'. The active power loss at a DC Pole = idleLoss + switchingLoss*|Idc| + resitiveLoss*Idc^2 For lossless operation Pdc=Pac For rectifier operation with losses Pdc=Pac-lossP For inverter operation with losses Pdc=Pac+lossP Converter state variable used in power flow. Default: 0.0", "type": "number" }, "q": { "description": "Property. Model:'https://schema.org/Number'. Reactive power at the point of common coupling. Load sign convention is used, i.e. positive sign means flow out from a node. Starting value for a steady state solution in the case a simplified power flow model is used. Default: 0.0", "type": "number" }, "ratedUdc": { "description": "Property. Model:'https://schema.org/Number'. Rated converter DC voltage, also called UdN. Converter configuration data used in power flow. Default: 0.0", "type": "number" }, "resistiveLoss": { "description": "Property. Model:'https://schema.org/Number'. Converter configuration data used in power flow. Refer to poleLossP. Default: 0.0", "type": "number" }, "switchingLoss": { "description": "Property. Model:'https://schema.org/Number'. Switching losses, relative to the base apparent power `baseS`. Refer to poleLossP. Default: 0.0", "type": "number" }, "targetPpcc": { "description": "Property. Model:'https://schema.org/Number'. Real power injection target in AC grid, at point of common coupling. Default: 0.0", "type": "number" }, "targetUdc": { "description": "Property. Model:'https://schema.org/Number'. Target value for DC voltage magnitude. Default: 0.0", "type": "number" }, "uc": { "description": "Property. Model:'https://schema.org/Number'. Converter voltage, the voltage at the AC side of the bridge. Converter state variable, result from power flow. Default: 0.0", "type": "number" }, "udc": { "description": "Property. Model:'https://schema.org/Number'. Converter voltage at the DC side, also called Ud. Converter state variable, result from power flow. Default: 0.0", "type": "number" }, "valveU0": { "description": "Property. Model:'https://schema.org/Number'. Valve threshold voltage. Forward voltage drop when the valve is conducting. Used in loss calculations, i.e. the switchLoss depend on numberOfValves * valveU0. Default: 0.0", "type": "number" } } } ] }