{ "$schema": "http://json-schema.org/schema#", "$schemaVersion": "0.0.1", "$id": "https://smart-data-models.github.io/dataModels.CIMEnergyClasses/ExcST6B/schema.json", "title": " Smart Data Models - ExcST6B", "description": "Adapted from CIM data models. Modified IEEE ST6B static excitation system with PID controller and optional inner feedbacks loop.", "type": "object", "allOf": [ { "$ref": "https://smart-data-models.github.io/data-models/common-schema.json#/definitions/GSMA-Commons" }, { "$ref": "https://smart-data-models.github.io/data-models/common-schema.json#/definitions/Location-Commons" }, { "properties": { "type": { "type": "string", "enum": [ "ExcST6B" ], "description": "Property. NGSI type. It has to be ExcST6B" }, "ilr": { "description": "Property. Model:'https://schema.org/Number'. Exciter output current limit reference (Ilr). Typical Value = 4.164. Default: 0.0", "type": "number" }, "k1": { "description": "Property. Model:'https://schema.org/Number'. Selector (K1). true = feedback is from Ifd false = feedback is not from Ifd. Typical Value = true. Default: False", "type": "number" }, "kcl": { "description": "Property. Model:'https://schema.org/Number'. Exciter output current limit adjustment (Kcl). Typical Value = 1.0577. Default: 0.0", "type": "number" }, "kff": { "description": "Property. Model:'https://schema.org/Number'. Pre-control gain constant of the inner loop field regulator (Kff). Typical Value = 1. Default: 0.0", "type": "number" }, "kg": { "description": "Property. Model:'https://schema.org/Number'. Feedback gain constant of the inner loop field regulator (Kg). Typical Value = 1. Default: 0.0", "type": "number" }, "kia": { "description": "Property. Model:'https://schema.org/Number'. Voltage regulator integral gain (Kia). Typical Value = 45.094. Default: 0.0", "type": "number" }, "klr": { "description": "Property. Model:'https://schema.org/Number'. Exciter output current limit adjustment (Kcl). Typical Value = 17.33. Default: 0.0", "type": "number" }, "km": { "description": "Property. Model:'https://schema.org/Number'. Forward gain constant of the inner loop field regulator (Km). Typical Value = 1. Default: 0.0", "type": "number" }, "kpa": { "description": "Property. Model:'https://schema.org/Number'. Voltage regulator proportional gain (Kpa). Typical Value = 18.038. Default: 0.0", "type": "number" }, "kvd": { "description": "Property. Model:'https://schema.org/Number'. Voltage regulator derivative gain (Kvd). Typical Value = 0. Default: 0.0", "type": "number" }, "oelin": { "description": "Property. Model:'https://schema.org/Number'. OEL input selector (OELin). Typical Value = noOELinput. Default: None", "type": "number" }, "tg": { "description": "Property. Model:'https://schema.org/Number'. Feedback time constant of inner loop field voltage regulator (Tg). Typical Value = 0.02. Default: 0", "type": "number" }, "ts": { "description": "Property. Model:'https://schema.org/Number'. Rectifier firing time constant (Ts). Typical Value = 0. Default: 0", "type": "number" }, "tvd": { "description": "Property. Model:'https://schema.org/Number'. Voltage regulator derivative gain (Tvd). Typical Value = 0. Default: 0", "type": "number" }, "vamax": { "description": "Property. Model:'https://schema.org/Number'. Maximum voltage regulator output (Vamax). Typical Value = 4.81. Default: 0.0", "type": "number" }, "vamin": { "description": "Property. Model:'https://schema.org/Number'. Minimum voltage regulator output (Vamin). Typical Value = -3.85. Default: 0.0", "type": "number" }, "vilim": { "description": "Property. Model:'https://schema.org/Number'. Selector (Vilim). true = Vimin-Vimax limiter is active false = Vimin-Vimax limiter is not active. Typical Value = true. Default: False", "type": "number" }, "vimax": { "description": "Property. Model:'https://schema.org/Number'. Maximum voltage regulator input limit (Vimax). Typical Value = 10. Default: 0.0", "type": "number" }, "vimin": { "description": "Property. Model:'https://schema.org/Number'. Minimum voltage regulator input limit (Vimin). Typical Value = -10. Default: 0.0", "type": "number" }, "vmult": { "description": "Property. Model:'https://schema.org/Number'. Selector (Vmult). true = multiply regulator output by terminal voltage false = do not multiply regulator output by terminal voltage. Typical Value = true. Default: False", "type": "number" }, "vrmax": { "description": "Property. Model:'https://schema.org/Number'. Maximum voltage regulator output (Vrmax). Typical Value = 4.81. Default: 0.0", "type": "number" }, "vrmin": { "description": "Property. Model:'https://schema.org/Number'. Minimum voltage regulator output (Vrmin). Typical Value = -3.85. Default: 0.0", "type": "number" }, "xc": { "description": "Property. Model:'https://schema.org/Number'. Excitation source reactance (Xc). Typical Value = 0.05. Default: 0.0", "type": "number" } } } ] }