{ "$schema": "http://json-schema.org/schema#", "$schemaVersion": "0.0.1", "$id": "https://smart-data-models.github.io/dataModels.CIMEnergyClasses/WindContPType3IEC/schema.json", "title": " Smart Data Models - WindContPType3IEC", "description": "Adapted from CIM data models. P control model Type 3. Reference: IEC Standard 61400-27-1 Section 6.6.5.3.", "type": "object", "allOf": [ { "$ref": "https://smart-data-models.github.io/data-models/common-schema.json#/definitions/GSMA-Commons" }, { "$ref": "https://smart-data-models.github.io/data-models/common-schema.json#/definitions/Location-Commons" }, { "properties": { "type": { "type": "string", "enum": [ "WindContPType3IEC" ], "description": "Property. NGSI type. It has to be WindContPType3IEC" }, "WindDynamicsLookupTable": { "description": "Property. Model:'https://schema.org/Number'. The P control type 3 model with which this wind dynamics lookup table is associated. Default: 'list'", "type": "number" }, "WindGenTurbineType3IEC": { "description": "Property. Model:'https://schema.org/Number'. Wind turbine type 3 model with which this Wind control P type 3 model is associated. Default: None", "type": "number" }, "dpmax": { "description": "Property. Model:'https://schema.org/Number'. Maximum wind turbine power ramp rate (). It is project dependent parameter. Default: 0.0", "type": "number" }, "dtrisemaxlvrt": { "description": "Property. Model:'https://schema.org/Number'. Limitation of torque rise rate during LVRT for S (d). It is project dependent parameter. Default: 0.0", "type": "number" }, "kdtd": { "description": "Property. Model:'https://schema.org/Number'. Gain for active drive train damping (). It is type dependent parameter. Default: 0.0", "type": "number" }, "kip": { "description": "Property. Model:'https://schema.org/Number'. PI controller integration parameter (). It is type dependent parameter. Default: 0.0", "type": "number" }, "kpp": { "description": "Property. Model:'https://schema.org/Number'. PI controller proportional gain (). It is type dependent parameter. Default: 0.0", "type": "number" }, "mplvrt": { "description": "Property. Model:'https://schema.org/Number'. Enable LVRT power control mode (M true = 1: voltage control false = 0: reactive power control. It is project dependent parameter. Default: False", "type": "number" }, "omegaoffset": { "description": "Property. Model:'https://schema.org/Number'. Offset to reference value that limits controller action during rotor speed changes (omega). It is case dependent parameter. Default: 0.0", "type": "number" }, "pdtdmax": { "description": "Property. Model:'https://schema.org/Number'. Maximum active drive train damping power (). It is type dependent parameter. Default: 0.0", "type": "number" }, "rramp": { "description": "Property. Model:'https://schema.org/Number'. Ramp limitation of torque, required in some grid codes (). It is project dependent parameter. Default: 0.0", "type": "number" }, "tdvs": { "description": "Property. Model:'https://schema.org/Number'. Timedelay after deep voltage sags (T). It is project dependent parameter. Default: 0", "type": "number" }, "temin": { "description": "Property. Model:'https://schema.org/Number'. Minimum electrical generator torque (). It is type dependent parameter. Default: 0.0", "type": "number" }, "tomegafilt": { "description": "Property. Model:'https://schema.org/Number'. Filter time constant for generator speed measurement (). It is type dependent parameter. Default: 0", "type": "number" }, "tpfilt": { "description": "Property. Model:'https://schema.org/Number'. Filter time constant for power measurement (). It is type dependent parameter. Default: 0", "type": "number" }, "tpord": { "description": "Property. Model:'https://schema.org/Number'. Time constant in power order lag (). It is type dependent parameter. Default: 0.0", "type": "number" }, "tufilt": { "description": "Property. Model:'https://schema.org/Number'. Filter time constant for voltage measurement (). It is type dependent parameter. Default: 0", "type": "number" }, "tuscale": { "description": "Property. Model:'https://schema.org/Number'. Voltage scaling factor of reset-torque (T). It is project dependent parameter. Default: 0.0", "type": "number" }, "twref": { "description": "Property. Model:'https://schema.org/Number'. Time constant in speed reference filter (). It is type dependent parameter. Default: 0", "type": "number" }, "udvs": { "description": "Property. Model:'https://schema.org/Number'. Voltage limit for hold LVRT status after deep voltage sags (). It is project dependent parameter. Default: 0.0", "type": "number" }, "updip": { "description": "Property. Model:'https://schema.org/Number'. Voltage dip threshold for P-control (). Part of turbine control, often different (e.g 0.8) from converter thresholds. It is project dependent parameter. Default: 0.0", "type": "number" }, "wdtd": { "description": "Property. Model:'https://schema.org/Number'. Active drive train damping frequency (omega). It can be calculated from two mass model parameters. It is type dependent parameter. Default: 0.0", "type": "number" }, "zeta": { "description": "Property. Model:'https://schema.org/Number'. Coefficient for active drive train damping (zeta). It is type dependent parameter. Default: 0.0", "type": "number" } } } ] }