{ "$schema": "http://json-schema.org/schema#", "$schemaVersion": "0.0.1", "$id": "https://smart-data-models.github.io/dataModels.CIMEnergyClasses/UnderexcLimIEEE2/schema.json", "title": " Smart Data Models - UnderexcLimIEEE2", "description": "Adapted from CIM data models. The class represents the Type UEL2 which has either a straight-line or multi-segment characteristic when plotted in terms of machine reactive power output vs. real power output. Reference: IEEE UEL2 421.5-2005 Section 10.2. (Limit characteristic lookup table shown in Figure 10.4 (p 32) of the standard).", "type": "object", "allOf": [ { "$ref": "https://smart-data-models.github.io/data-models/common-schema.json#/definitions/GSMA-Commons" }, { "$ref": "https://smart-data-models.github.io/data-models/common-schema.json#/definitions/Location-Commons" }, { "properties": { "type": { "type": "string", "enum": [ "UnderexcLimIEEE2" ], "description": "Property. NGSI type. It has to be UnderexcLimIEEE2" }, "k1": { "description": "Property. Model:'https://schema.org/Number'. UEL terminal voltage exponent applied to real power input to UEL limit look-up table (k1). Typical Value = 2. Default: 0.0", "type": "number" }, "k2": { "description": "Property. Model:'https://schema.org/Number'. UEL terminal voltage exponent applied to reactive power output from UEL limit look-up table (k2). Typical Value = 2. Default: 0.0", "type": "number" }, "kfb": { "description": "Property. Model:'https://schema.org/Number'. Gain associated with optional integrator feedback input signal to UEL (K). Typical Value = 0. Default: 0.0", "type": "number" }, "kuf": { "description": "Property. Model:'https://schema.org/Number'. UEL excitation system stabilizer gain (K). Typical Value = 0. Default: 0.0", "type": "number" }, "kui": { "description": "Property. Model:'https://schema.org/Number'. UEL integral gain (K). Typical Value = 0.5. Default: 0.0", "type": "number" }, "kul": { "description": "Property. Model:'https://schema.org/Number'. UEL proportional gain (K). Typical Value = 0.8. Default: 0.0", "type": "number" }, "p0": { "description": "Property. Model:'https://schema.org/Number'. Real power values for endpoints (P). Typical Value = 0. Default: 0.0", "type": "number" }, "p1": { "description": "Property. Model:'https://schema.org/Number'. Real power values for endpoints (P). Typical Value = 0.3. Default: 0.0", "type": "number" }, "p10": { "description": "Property. Model:'https://schema.org/Number'. Real power values for endpoints (P). Default: 0.0", "type": "number" }, "p2": { "description": "Property. Model:'https://schema.org/Number'. Real power values for endpoints (P). Typical Value = 0.6. Default: 0.0", "type": "number" }, "p3": { "description": "Property. Model:'https://schema.org/Number'. Real power values for endpoints (P). Typical Value = 0.9. Default: 0.0", "type": "number" }, "p4": { "description": "Property. Model:'https://schema.org/Number'. Real power values for endpoints (P). Typical Value = 1.02. Default: 0.0", "type": "number" }, "p5": { "description": "Property. Model:'https://schema.org/Number'. Real power values for endpoints (P). Default: 0.0", "type": "number" }, "p6": { "description": "Property. Model:'https://schema.org/Number'. Real power values for endpoints (P). Default: 0.0", "type": "number" }, "p7": { "description": "Property. Model:'https://schema.org/Number'. Real power values for endpoints (P). Default: 0.0", "type": "number" }, "p8": { "description": "Property. Model:'https://schema.org/Number'. Real power values for endpoints (P). Default: 0.0", "type": "number" }, "p9": { "description": "Property. Model:'https://schema.org/Number'. Real power values for endpoints (P). Default: 0.0", "type": "number" }, "q0": { "description": "Property. Model:'https://schema.org/Number'. Reactive power values for endpoints (Q). Typical Value = -0.31. Default: 0.0", "type": "number" }, "q1": { "description": "Property. Model:'https://schema.org/Number'. Reactive power values for endpoints (Q). Typical Value = -0.31. Default: 0.0", "type": "number" }, "q10": { "description": "Property. Model:'https://schema.org/Number'. Reactive power values for endpoints (Q). Default: 0.0", "type": "number" }, "q2": { "description": "Property. Model:'https://schema.org/Number'. Reactive power values for endpoints (Q). Typical Value = -0.28. Default: 0.0", "type": "number" }, "q3": { "description": "Property. Model:'https://schema.org/Number'. Reactive power values for endpoints (Q). Typical Value = -0.21. Default: 0.0", "type": "number" }, "q4": { "description": "Property. Model:'https://schema.org/Number'. Reactive power values for endpoints (Q). Typical Value = 0. Default: 0.0", "type": "number" }, "q5": { "description": "Property. Model:'https://schema.org/Number'. Reactive power values for endpoints (Q). Default: 0.0", "type": "number" }, "q6": { "description": "Property. Model:'https://schema.org/Number'. Reactive power values for endpoints (Q). Default: 0.0", "type": "number" }, "q7": { "description": "Property. Model:'https://schema.org/Number'. Reactive power values for endpoints (Q). Default: 0.0", "type": "number" }, "q8": { "description": "Property. Model:'https://schema.org/Number'. Reactive power values for endpoints (Q). Default: 0.0", "type": "number" }, "q9": { "description": "Property. Model:'https://schema.org/Number'. Reactive power values for endpoints (Q). Default: 0.0", "type": "number" }, "tu1": { "description": "Property. Model:'https://schema.org/Number'. UEL lead time constant (T). Typical Value = 0. Default: 0", "type": "number" }, "tu2": { "description": "Property. Model:'https://schema.org/Number'. UEL lag time constant (T). Typical Value = 0. Default: 0", "type": "number" }, "tu3": { "description": "Property. Model:'https://schema.org/Number'. UEL lead time constant (T). Typical Value = 0. Default: 0", "type": "number" }, "tu4": { "description": "Property. Model:'https://schema.org/Number'. UEL lag time constant (T). Typical Value = 0. Default: 0", "type": "number" }, "tul": { "description": "Property. Model:'https://schema.org/Number'. Time constant associated with optional integrator feedback input signal to UEL (T). Typical Value = 0. Default: 0", "type": "number" }, "tup": { "description": "Property. Model:'https://schema.org/Number'. Real power filter time constant (T). Typical Value = 5. Default: 0", "type": "number" }, "tuq": { "description": "Property. Model:'https://schema.org/Number'. Reactive power filter time constant (T). Typical Value = 0. Default: 0", "type": "number" }, "tuv": { "description": "Property. Model:'https://schema.org/Number'. Voltage filter time constant (T). Typical Value = 5. Default: 0", "type": "number" }, "vuimax": { "description": "Property. Model:'https://schema.org/Number'. UEL integrator output maximum limit (V). Typical Value = 0.25. Default: 0.0", "type": "number" }, "vuimin": { "description": "Property. Model:'https://schema.org/Number'. UEL integrator output minimum limit (V). Typical Value = 0. Default: 0.0", "type": "number" }, "vulmax": { "description": "Property. Model:'https://schema.org/Number'. UEL output maximum limit (V). Typical Value = 0.25. Default: 0.0", "type": "number" }, "vulmin": { "description": "Property. Model:'https://schema.org/Number'. UEL output minimum limit (V). Typical Value = 0. Default: 0.0", "type": "number" } } } ] }