{ "$schema": "http://json-schema.org/schema#", "$schemaVersion": "0.0.1", "$id": "https://smart-data-models.github.io/dataModels.CIMEnergyClasses/ExcHU/schema.json", "title": " Smart Data Models - ExcHU", "description": "Adapted from CIM data models. Hungarian Excitation System Model, with built-in voltage transducer.", "type": "object", "allOf": [ { "$ref": "https://smart-data-models.github.io/data-models/common-schema.json#/definitions/GSMA-Commons" }, { "$ref": "https://smart-data-models.github.io/data-models/common-schema.json#/definitions/Location-Commons" }, { "properties": { "type": { "type": "string", "enum": [ "ExcHU" ], "description": "Property. NGSI type. It has to be ExcHU" }, "ae": { "description": "Property. Model:'https://schema.org/Number'. Major loop PI tag gain factor (Ae). Typical Value = 3. Default: 0.0", "type": "number" }, "ai": { "description": "Property. Model:'https://schema.org/Number'. Minor loop PI tag gain factor (Ai). Typical Value = 22. Default: 0.0", "type": "number" }, "atr": { "description": "Property. Model:'https://schema.org/Number'. AVR constant (Atr). Typical Value = 2.19. Default: 0.0", "type": "number" }, "emax": { "description": "Property. Model:'https://schema.org/Number'. Field voltage control signal upper limit on AVR base (Emax). Typical Value = 0.996. Default: 0.0", "type": "number" }, "emin": { "description": "Property. Model:'https://schema.org/Number'. Field voltage control signal lower limit on AVR base (Emin). Typical Value = -0.866. Default: 0.0", "type": "number" }, "imax": { "description": "Property. Model:'https://schema.org/Number'. Major loop PI tag output signal upper limit (Imax). Typical Value = 2.19. Default: 0.0", "type": "number" }, "imin": { "description": "Property. Model:'https://schema.org/Number'. Major loop PI tag output signal lower limit (Imin). Typical Value = 0.1. Default: 0.0", "type": "number" }, "ke": { "description": "Property. Model:'https://schema.org/Number'. Voltage base conversion constant (Ke). Typical Value = 4.666. Default: 0.0", "type": "number" }, "ki": { "description": "Property. Model:'https://schema.org/Number'. Current base conversion constant (Ki). Typical Value = 0.21428. Default: 0.0", "type": "number" }, "te": { "description": "Property. Model:'https://schema.org/Number'. Major loop PI tag integration time constant (Te). Typical Value = 0.154. Default: 0", "type": "number" }, "ti": { "description": "Property. Model:'https://schema.org/Number'. Minor loop PI control tag integration time constant (Ti). Typical Value = 0.01333. Default: 0", "type": "number" }, "tr": { "description": "Property. Model:'https://schema.org/Number'. Filter time constant (Tr). If a voltage compensator is used in conjunction with this excitation system model, Tr should be set to 0. Typical Value = 0.01. Default: 0", "type": "number" } } } ] }