{ "$schema": "http://json-schema.org/schema#", "$schemaVersion": "0.0.1", "$id": "https://smart-data-models.github.io/dataModels.CIMEnergyClasses/GovHydroWPID/schema.json", "title": " Smart Data Models - GovHydroWPID", "description": "Adapted from CIM data models. Woodward PID Hydro Governor.", "type": "object", "allOf": [ { "$ref": "https://smart-data-models.github.io/data-models/common-schema.json#/definitions/GSMA-Commons" }, { "$ref": "https://smart-data-models.github.io/data-models/common-schema.json#/definitions/Location-Commons" }, { "properties": { "type": { "type": "string", "enum": [ "GovHydroWPID" ], "description": "Property. NGSI type. It has to be GovHydroWPID" }, "d": { "description": "Property. Model:'https://schema.org/Number'. Turbine damping factor (D). Unit = delta P / delta speed. Default: 0.0", "type": "number" }, "gatmax": { "description": "Property. Model:'https://schema.org/Number'. Gate opening Limit Maximum (Gatmax). Default: 0.0", "type": "number" }, "gatmin": { "description": "Property. Model:'https://schema.org/Number'. Gate opening Limit Minimum (Gatmin). Default: 0.0", "type": "number" }, "gv1": { "description": "Property. Model:'https://schema.org/Number'. Gate position 1 (Gv1). Default: 0.0", "type": "number" }, "gv2": { "description": "Property. Model:'https://schema.org/Number'. Gate position 2 (Gv2). Default: 0.0", "type": "number" }, "gv3": { "description": "Property. Model:'https://schema.org/Number'. Gate position 3 (Gv3). Default: 0.0", "type": "number" }, "kd": { "description": "Property. Model:'https://schema.org/Number'. Derivative gain (Kd). Typical Value = 1.11. Default: 0.0", "type": "number" }, "ki": { "description": "Property. Model:'https://schema.org/Number'. Reset gain (Ki). Typical Value = 0.36. Default: 0.0", "type": "number" }, "kp": { "description": "Property. Model:'https://schema.org/Number'. Proportional gain (Kp). Typical Value = 0.1. Default: 0.0", "type": "number" }, "mwbase": { "description": "Property. Model:'https://schema.org/Number'. Base for power values (MWbase) (>0). Unit = MW. Default: 0.0", "type": "number" }, "pgv1": { "description": "Property. Model:'https://schema.org/Number'. Output at Gv1 PU of MWbase (Pgv1). Default: 0.0", "type": "number" }, "pgv2": { "description": "Property. Model:'https://schema.org/Number'. Output at Gv2 PU of MWbase (Pgv2). Default: 0.0", "type": "number" }, "pgv3": { "description": "Property. Model:'https://schema.org/Number'. Output at Gv3 PU of MWbase (Pgv3). Default: 0.0", "type": "number" }, "pmax": { "description": "Property. Model:'https://schema.org/Number'. Maximum Power Output (Pmax). Default: 0.0", "type": "number" }, "pmin": { "description": "Property. Model:'https://schema.org/Number'. Minimum Power Output (Pmin). Default: 0.0", "type": "number" }, "reg": { "description": "Property. Model:'https://schema.org/Number'. Permanent drop (Reg). Default: 0.0", "type": "number" }, "ta": { "description": "Property. Model:'https://schema.org/Number'. Controller time constant (Ta) (>0). Typical Value = 0. Default: 0", "type": "number" }, "tb": { "description": "Property. Model:'https://schema.org/Number'. Gate servo time constant (Tb) (>0). Typical Value = 0. Default: 0", "type": "number" }, "treg": { "description": "Property. Model:'https://schema.org/Number'. Speed detector time constant (Treg). Default: 0", "type": "number" }, "tw": { "description": "Property. Model:'https://schema.org/Number'. Water inertia time constant (Tw) (>0). Typical Value = 0. Default: 0", "type": "number" }, "velmax": { "description": "Property. Model:'https://schema.org/Number'. Maximum gate opening velocity (Velmax). Unit = PU/sec. Typical Value = 0. Default: 0.0", "type": "number" }, "velmin": { "description": "Property. Model:'https://schema.org/Number'. Maximum gate closing velocity (Velmin). Unit = PU/sec. Typical Value = 0. Default: 0.0", "type": "number" } } } ] }