B COMPLETE BUILDINGS/ STRUCTURES/ UNITS B06 ENGINEERING SERVICES GENERAL DESCRIPTION B B06/110 EXISTING SITE AND SERVICES B06 B06/120 BUILDING WORKS B06 B06/130 DISPOSAL SYSTEMS B06 B06/140 WATER SUPPLY SYSTEMS B06 B06/150 MEDICAL GAS SUPPLY SYSTEMS B06 B06/160 GAS SUPPLY SYSTEMS B06 B06/170 LIQUID FUEL SUPPLY SYSTEMS B06 B06/180 STEAM SUPPLY SYSTEMS B06 B06/190 FIRE FIGHTING SYSTEMS B06 B06/200 HEATING SYSTEMS B06 B06/210 COOLING SYSTEMS B06 B06/220 VENTILATION SYSTEMS B06 B06/230 AIR CONDITIONING SYSTEMS B06 B06/240 HIGH VOLTAGE SYSTEMS B06 B06/250 LOW VOLTAGE SYSTEMS B06 B06/260 GENERAL AND EMERGENCY LIGHTING SYSTEMS B06 B06/270 COMMUNICATION SYSTEMS B06 B06/280 TELECOMMUNICATION AND DATA SYSTEMS B06 B06/290 SECURITY SYSTEMS B06 B06/300 DETECTION AND ALARM SYSTEMS B06 B06/310 PROTECTION SYSTEMS B06 B06/315 DISPLAY AND INFORMATION SYSTEMS B06 B06/320 TRANSPORT SYSTEMS B06 B06/330 CONTROL SYSTEMS B06 B11 PREFABRICATED BUILDING UNITS B B11/10 INFORMATION TO BE PROVIDED WITH TENDER B11 B11/110 PREFABRICATED B11 B11/205 CONTRACTOR'S DESIGN B11 B11/207 STRUCTURAL DESIGN PROVIDED B11 B11/210 SURROUNDING STRUCTURE/ FABRIC - PERFORMANCE VALUES B11 B11/215 SURROUNDING STRUCTURE/ FABRIC - PERFORMANCE ASSESSMENT B11 B11/225 ACOUSTIC PERFORMANCE B11 B11/240 THERMAL INSULATION B11 B11/245 DURABILITY B11 B11/255 INTERSTITIAL CONDENSATION B11 B11/261 SURFACE CONDENSATION B11 B11/265 IMPACT RESISTANCE OF NON-LOADBEARING VERTICAL SURFACES B11 B11/510 INFORMATION FROM MANUFACTURER B11 B11/700 PROTOTYPES B11 B11/710 TRANSPORTATION B11 B11/740 SUPPORTING STRUCTURE B11 B11/750 INSTALLATION B11 B11/760 ASSEMBLY B11 B11/910 DOCUMENTATION B11 B13 MODULAR BUILDINGS B B13/10 INFORMATION TO BE PROVIDED WITH TENDER B13 B13/110 MODULAR B13 B13/210 CONTRACTOR'S DESIGN B13 B13/212 STRUCTURAL DESIGN PROVIDED B13 B13/225 ACOUSTIC PERFORMANCE OF DWELLINGS B13 B13/231 ACOUSTIC PERFORMANCE OF SCHOOLS B13 B13/235 ACOUSTIC PERFORMANCE B13 B13/241 THERMAL INSULATION B13 B13/245 DURABILITY B13 B13/251 WATER PENETRATION B13 B13/255 INTERSTITIAL CONDENSATION B13 B13/257 INTERSTITIAL CONDENSATION B13 B13/261 SURFACE CONDENSATION B13 B13/263 IMPACT RESISTANCE OF NON-LOADBEARING VERTICAL SURFACES B13 B13/265 ADDITIONAL SECURITY B13 B13/267 ACCESSIBLE DESIGN B13 B13/270 BREEAM B13 B13/280 CODE FOR SUSTAINABLE HOMES B13 B13/510 INFORMATION FROM MANUFACTURER B13 B13/700 PROTOTYPE B13 B13/710 TRANSPORTATION B13 B13/740 SUPPORTING STRUCTURE B13 B13/750 ERECTION B13 B13/760 ASSEMBLY B13 B13/770 ACCURACY OF ERECTION B13 B13/910 DOCUMENTATION B13 B14 PREFABRICATED PANELLED CONSTRUCTIONS B B14/10 INFORMATION TO BE PROVIDED WITH TENDER B14 B14/110 PREFABRICATED PANELLED B14 B14/210 CONTRACTOR'S DESIGN B14 B14/212 STRUCTURAL DESIGN PROVIDED B14 B14/225 ACOUSTIC PERFORMANCE – DWELLINGS B14 B14/230 ACOUSTIC PERFORMANCE – SCHOOLS B14 B14/235 ACOUSTIC PERFORMANCE B14 B14/240 THERMAL INSULATION B14 B14/245 DURABILITY B14 B14/250 WATER PENETRATION B14 B14/255 INTERSTITIAL CONDENSATION B14 B14/260 SURFACE CONDENSATION B14 B14/262 IMPACT RESISTANCE OF NON-LOADBEARING VERTICAL SURFACES B14 B14/265 ADDITIONAL SECURITY B14 B14/270 BREEAM B14 B14/280 CODE FOR SUSTAINABLE HOMES B14 B14/510 INFORMATION FROM MANUFACTURER B14 B14/710 GENERAL B14 B14/715 SAMPLE PANELS B14 B14/720 SUPPORTING STRUCTURE B14 B14/730 ERECTION B14 B14/740 ACCURACY OF ERECTION B14 B14/910 DOCUMENTATION B14 B15 PREFABRICATED FRAMED CONSTRUCTIONS B B15/10 INFORMATION TO BE PROVIDED WITH TENDER B15 B15/110 TIMBER FRAMED B15 B15/120 TIMBER FRAMED B15 B15/130 LIGHT GAUGE STEEL FRAME B15 B15/140 PRECAST CONCRETE FRAME B15 B15/210 CONTRACTOR'S DESIGN B15 B15/212 STRUCTURAL DESIGN PROVIDED B15 B15/225 ACOUSTIC PERFORMANCE – DWELLINGS B15 B15/230 ACOUSTIC PERFORMANCE – SCHOOLS B15 B15/235 ACOUSTIC PERFORMANCE B15 B15/240 THERMAL INSULATION B15 B15/245 DURABILITY B15 B15/250 WATER PENETRATION B15 B15/255 INTERSTITIAL CONDENSATION B15 B15/260 SURFACE CONDENSATION B15 B15/262 IMPACT RESISTANCE OF NON-LOADBEARING VERTICAL SURFACES B15 B15/265 ADDITIONAL SECURITY B15 B15/270 BREEAM B15 B15/280 CODE FOR SUSTAINABLE HOMES B15 B15/510 INFORMATION FROM MANUFACTURER B15 B15/710 TRANSPORTATION B15 B15/720 DELIVERY B15 B15/730 STORAGE B15 B15/740 SUPPORTING STRUCTURE B15 B15/750 ERECTION B15 B15/760 ASSEMBLY B15 B15/770 ACCURACY OF ERECTION B15 B15/910 DOCUMENTATION B15 B50 GENERAL STRUCTURAL REQUIREMENTS B B50/10 INFORMATION TO BE PROVIDED WITH TENDER B50 B50/110 EUROCODES B50 B50/120 STRUCTURAL WORK B50 B50/130 CONTRACTOR'S DESIGN B50 B50/140 CONTRACTOR'S DESIGN - ADDITIONAL REQUIREMENTS FOR GEOTECHNICAL WORK B50 B50/15 INFORMATION TO BE PROVIDED AT TIME OF TENDER B50 B50/150 GROUND INVESTIGATION REPORT B50 B50/160 GEOTECHNICAL DESIGN REPORT B50 B50/210 CONSEQUENCE FOR LOCALIZED FAILURE FROM AN UNSPECIFIED CAUSE B50 B50/220 EXPOSURE TO FIRE B50 B50/230 PERFORMANCE CRITERIA FOR STRUCTURE TO BE SUPPORTED B50 B50/240 PERFORMANCE CRITERIA FOR RETAINING STRUCTURES B50 B50/250 LIMITS ON MOVEMENT GENERATED BY CONSTRUCTION B50 B50/260 LATERAL MOVEMENT OF EMBEDDED RETAINING WALLS DURING EXCAVATION AND CONSTRUCTION B50 B50/270 LIMITS ON GROUND MOVEMENT B50 B50/280 SETTLEMENT OF EXISTING STRUCTURES B50 B50/290 LATERAL DISPLACEMENT OF EXISTING STRUCTURES B50 B50/300 VIBRATION OF EXISTING STRUCTURES B50 B50/310 DAMAGE TO EXISTING STRUCTURES AND SERVICES B50 B50/320 LOADS/ ACTIONS B50 B50/330 DESIGN LOADS B50 B50/340 PERMANENT AND IMPOSED LOADS B50 B50/350 DEAD AND IMPOSED LOADS B50 B50/360 LOADING FOR MECHANICAL AND ELECTRICAL SERVICES B50 B50/370 LOADING FOR RELOCATABLE PARTITIONS B50 B50/380 LOADS IN ROOF AND CEILING VOIDS B50 B50/390 IMPOSED LOADS ON PARAPETS AND BARRIERS B50 B50/400 ACTIONS ON NON-LOADBEARING B50 B50/410 DATA FOR CLIMATIC LOADS/ ACTIONS B50 B50/420 SNOW LOADS B50 B50/430 SNOW LOADS - CONTRACTOR DETERMINED B50 B50/440 ICE LOADS/ ACTIONS B50 B50/450 WIND PRESSURES B50 B50/460 WIND LOADS/ ACTIONS B50 B50/470 WIND LOADS/ ACTIONS - CONTRACTOR DETERMINED B50 B50/480 WIND LOADS/ ACTIONS - ADDITIONAL REQUIREMENTS FOR FAÇADE RETENTION B50 B50/490 THERMAL ACTIONS B50 B50/500 IMPACT FORCES B50 B50/504 IMPACT RESISTANCE OF VERTICAL CLADDING B50 B50/506 IMPACT RESISTANCE OF VERTICAL B50 B50/510 ACCIDENTAL LOADING OF FAÇADE/ FAÇADE RETENTION STRUCTURE B50 B50/520 FOUNDATION - LOADS B50 B50/530 EARTH RETAINING LOADS B50 B50/540 EARTH RETAINING LOADS - CONTRACTOR DETERMINED B50 B50/550 VEHICLE SURCHARGE LOADS B50 B50/560 DIAPHRAGM ACTION B50 B50/700 EXECUTION GENERALLY B50 B50/705 CONNECTIONS AND ANCHORAGES B50 B50/710 GEOTECHNICAL WORK B50 B50/720 STABILITY DURING EXECUTION B50 B50/730 RESTRICTIONS ON USE OF GROUND SURFACE BEHIND EARTH RETAINING STRUCTURES B50 B50/740 CONDITION SURVEY OF EXISTING BUILDINGS AND STRUCTURES B50 B50/750 MONITORING OF GROUND CONDITIONS DURING CONSTRUCTION B50 B50/760 MONITORING OF EXISTING BUILDINGS/ STRUCTURES B50 B50/770 MOVEMENT MONITORING B50 B50/780 CRACK MONITORING OF EXISTING BUILDINGS/ STRUCTURES B50 B50/790 FREQUENCY OF MONITORING B50 B50/900 GEOTECHNICAL RECORDS B50 B51 GENERAL STRUCTURAL REQUIREMENTS - LANDSCAPE B B51/110 EUROCODES B51 B51/120 STRUCTURAL WORK B51 B51/130 CONTRACTOR'S DESIGN B51 B51/140 CONTRACTOR'S DESIGN - ADDITIONAL REQUIREMENTS FOR GEOTECHNICAL WORK B51 B51/15 INFORMATION TO BE PROVIDED AT TIME OF TENDER B51 B51/150 GROUND INVESTIGATION REPORT B51 B51/160 GEOTECHNICAL DESIGN REPORT B51 B51/220 EXPOSURE TO FIRE B51 B51/230 PERFORMANCE CRITERIA FOR STRUCTURE TO BE SUPPORTED B51 B51/250 LIMITS ON MOVEMENT GENERATED BY CONSTRUCTION B51 B51/280 SETTLEMENT OF EXISTING STRUCTURES B51 B51/320 LOADS/ ACTIONS B51 B51/330 DESIGN LOADS B51 B51/410 DATA FOR CLIMATIC LOADS/ ACTIONS B51 B51/430 SNOW LOADS - CONTRACTOR DETERMINED B51 B51/470 WIND LOADS/ ACTIONS - CONTRACTOR DETERMINED B51 B51/500 IMPACT FORCES B51 B51/520 FOUNDATION - LOADS B51 B51/540 EARTH RETAINING LOADS - CONTRACTOR DETERMINED B51 B51/700 EXECUTION GENERALLY B51 B51/705 CONNECTIONS AND ANCHORAGES B51 B51/710 GEOTECHNICAL WORK B51 B51/730 RESTRICTIONS ON USE OF GROUND SURFACE BEHIND EARTH RETAINING STRUCTURES B51 B51/740 CONDITION SURVEY AND MONITORING OF EXISTING BUILDINGS AND STRUCTURES B51 B51/750 MONITORING OF GROUND CONDITIONS DURING CONSTRUCTION B51 B51/900 GEOTECHNICAL RECORDS B51 B91 BUILDINGS IN THE LANDSCAPE B B91/105 PROPRIETARY SMALL BUILDINGS/ STRUCTURES B91 B91/110 DESIGNED/ BESPOKE SMALL BUILDINGS/ STRUCTURES B91 B91/215 CONTRACTOR'S DESIGN B91 B91/217 STRUCTURAL DESIGN PROVIDED B91 B91/220 DURABILITY B91 B91/230 IMPACT RESISTANCE OF NON-LOADBEARING VERTICAL SURFACES B91 B91/240 WATER PENETRATION B91 B91/310 BANDSTAND B91 B91/315 BIRD HIDE B91 B91/320 BUS SHELTER B91 B91/325 CAGE B91 B91/330 CANOPY B91 B91/335 COVERED WALKWAY B91 B91/340 CYCLE SHELTER B91 B91/345 GREENHOUSE/ GLASSHOUSE B91 B91/350 KIOSK B91 B91/355 MOTORCYCLE SHELTER B91 B91/360 OUTDOOR CLASSROOM B91 B91/365 PAVILION/ GAZEBO B91 B91/370 PERGOLA/ ARBOUR B91 B91/375 POLYTUNNEL B91 B91/380 SHED B91 B91/385 SHELTER B91 B91/390 SMOKING SHELTER B91 B91/395 STORAGE UNIT B91 B91/400 SUMMER HOUSE B91 B91/405 TELEPHONE BOOTH B91 B91/410 TOILET UNIT B91 B91/415 TROLLEY SHELTER B91 B91/420 WAITING SHELTER B91 B91/425 YOUTH SHELTER B91 B91/430 ALUMINIUM B91 B91/435 CAST IRON B91 B91/440 WROUGHT IRON B91 B91/445 METAL PROFILE B91 B91/450 STAINLESS STEEL B91 B91/455 PLYWOOD B91 B91/460 TIMBER CLADDING B91 B91/465 WOOD COMPOSITES B91 B91/470 PLASTICS AND COMPOSITE MATERIALS B91 B91/475 GLASS B91 B91/480 GLAZING PLASTICS B91 B91/485 TENSILE FABRIC PERFORMANCE B91 B91/486 TENSILE FABRIC B91 B91/490 CLAY TILE B91 B91/491 CONCRETE TILE B91 B91/492 FIBRE CEMENT SLATE B91 B91/493 NATURAL SLATE B91 B91/494 WOOD SHINGLE B91 B91/600 ERECTION/ INSTALLATION GENERALLY B91 B91/605 JOINTING/ FIXING GENERALLY B91 B91/610 CONCRETE FOUNDATIONS GENERALLY B91 B91/615 SETTING COMPONENTS IN EARTH B91 B91/620 BUILDING IN TO MASONRY WALLS B91 B91/625 ELECTRICAL AND DATA SERVICES B91 B91/630 ERECTION OF PREFABRICATED BUILDINGS/ STRUCTURES B91 B91/635 INSTALLATION OF TIMBER FLOORING/SURFACING B91 B91/637 ERECTION OF TENSILE FABRIC ROOFS B91 B91/640 SITE PAINTING AND STAINING B91 B91/645 MAKING GOOD GALVANIZED SURFACES B91 B91/650 MAKING GOOD TREATED TIMBER B91 B91/930 DOCUMENTATION B91 C DEMOLITION/ ALTERATION/ RENOVATION C10 SITE SURVEY C C10/115 PRELIMINARY SURVEY C10 C10/125 SITE SURVEY - C10 C10/135 ASSESSMENT SURVEY C10 C10/145 ECOLOGICAL SURVEY C10 C10/155 ARBORICULTURAL SURVEY C10 C10/165 INVASIVE SPECIES SURVEY C10 C10/210 DESK STUDY C10 C10/215 SITE RECONNAISSANCE C10 C10/225 DIRECT MEASUREMENT SURVEYING C10 C10/235 ELECTRICAL RESISTIVITY MEASUREMENT C10 C10/245 GLOBAL POSITIONING SYSTEM (GPS) C10 C10/255 GROUND PENETRATING RADAR (GPR) C10 C10/265 LIGHT DETECTION AND RANGING (LIDAR) C10 C10/275 MAGNETOMETRY C10 C10/280 PHOTOGRAMMETRY C10 C10/410 BENCH MARKS C10 C10/420 UNFORESEEN HAZARDS C10 C10/430 SURVEY INSTRUMENTS C10 C10/440 PROTECTION C10 C10/910 DOCUMENTATION – PAPER C10 C10/915 DOCUMENTATION – ELECTRONIC C10 C10/920 PRESENTATION TO ACCOMPANY SURVEY REPORT C10 C10/925 PRELIMINARY SURVEY REPORT C10 C10/935 SITE SURVEY REPORT C10 C10/945 ASSESSMENT SURVEY REPORT C10 C10/955 ECOLOGICAL SURVEY REPORT C10 C10/965 ARBORICULTURAL SURVEY REPORT C10 C10/975 INVASIVE SPECIES SURVEY REPORT C10 C11 SITE INVESTIGATION C C11/110 EXTENT OF INVESTIGATION C11 C11/112 MONITORING OF GROUND CONDITIONS DURING CONSTRUCTION C11 C11/115 GEOTECHNICAL ADVISER C11 C11/120 PRELIMINARY WORK BY OTHERS C11 C11/125 GEOLOGY AND GROUND CONDITIONS C11 C11/130 BACKGROUND INFORMATION SOURCES C11 C11/140 ACCESS TO THE SITE C11 C11/150 PUBLIC SAFETY C11 C11/160 SITE SAFETY C11 C11/170 SURVEY INSTRUMENTS C11 C11/180 COMPETENCE C11 C11/190 PROTECTION C11 C11/205 PRESENTATION OF DATA AND INFORMATION C11 C11/210 DESK STUDY C11 C11/220 SITE RECONNAISSANCE C11 C11/230 DETAILED EXAMINATION/ SPECIAL STUDY C11 C11/240 GROUND INVESTIGATION C11 C11/242 CONTRACTOR DESIGNED GROUND INVESTIGATION C11 C11/246 TOLERANCE ON POSITION OF EXPLORATORY HOLES C11 C11/248 QUALITY OF GROUND INVESTIGATION C11 C11/250 TRIAL PITS AND TRENCHES C11 C11/260 OBSERVATION PITS AND TRENCHES C11 C11/265 SUBSTRUCTURE INSPECTION PITS C11 C11/270 BOREHOLES C11 C11/271 COMPLETION OF BOREHOLES C11 C11/272 ROTARY DRILLING C11 C11/275 INFORMATION C11 C11/280 IN SITU SOIL TESTS C11 C11/290 PERMEABILITY TESTS C11 C11/300 GEOPHYSICAL TESTS C11 C11/310 SPECIAL TESTS C11 C11/314 TELEVISION SURVEY OF BOREHOLES C11 C11/320 SOIL AND GROUNDWATER SAMPLING C11 C11/322 SPECIAL SAMPLING AND SPT TESTING IN BOREHOLES C11 C11/324 SPECIAL SAMPLING IN PITS AND TRENCHES C11 C11/325 BLOCK SAMPLING C11 C11/327 SAMPLING FOR CONTAMINATION TESTING C11 C11/329 GAS SAMPLING C11 C11/330 FIELD REPORTS AND BOREHOLE LOGS C11 C11/340 GROUNDWATER MONITORING C11 C11/344 GAS MONITORING C11 C11/350 LABORATORY TESTS FOR MECHANICAL PROPERTIES OF SOILS C11 C11/355 LABORATORY TESTS FOR MECHANICAL PROPERTIES OF ROCK C11 C11/360 LABORATORY TESTS FOR CHEMICAL PROPERTIES OF SOILS AND WATER C11 C11/370 INTERPRETATIVE REPORT C11 C11/380 FACTUAL REPORT C11 C12 UNDERGROUND SERVICES SURVEY C C12/110 EXTENT OF SURVEY C12 C12/120 PRELIMINARY WORK BY OTHERS C12 C12/140 BACKGROUND INFORMATION SOURCES C12 C12/150 ACCESS TO THE SITE C12 C12/160 UNFORESEEN HAZARDS C12 C12/170 SURVEY INSTRUMENTS C12 C12/180 WORKMANSHIP C12 C12/190 SAFETY OF THIRD PARTIES C12 C12/200 DATA COLLECTION C12 C12/610 DESK STUDY C12 C12/620 UNDERGROUND SERVICES SURVEY C12 C12/630 ANCILLARY WORK TO SURVEY C12 C12/640 PROTECTION C12 C12/810 SURVEY REPORT C12 C14 ENGINEERING SERVICES SURVEY C C14/110 EXTENT OF SURVEY C14 C14/120 PRELIMINARY WORK BY OTHERS C14 C14/130 BACKGROUND INFORMATION C14 C14/140 ACCESS TO THE SITE C14 C14/150 ACCESS TO PARTICULAR PLANT AREAS C14 C14/160 SITE RESTRICTIONS AND CONSTRAINTS C14 C14/170 UNFORESEEN HAZARDS C14 C14/175 SAFETY OF THIRD PARTIES C14 C14/180 TEST INSTRUMENTS C14 C14/185 SURVEYORS C14 C14/190 DATA COLLECTION C14 C14/195 PICTORIAL RECORD C14 C14/210 DESK STUDY C14 C14/215 PILOT SURVEY C14 C14/220 SYSTEM SURVEYS GENERALLY C14 C14/225 INCOMING WATER SUPPLY CONNECTION SURVEY C14 C14/230 HOT AND COLD WATER SUPPLY SYSTEMS SURVEY C14 C14/235 FOUNTAINS AND WATER FEATURES SURVEY C14 C14/240 GREY WATER RECLAMATION SYSTEMS SURVEY C14 C14/245 RAINWATER RECLAMATION SYSTEMS SURVEY C14 C14/250 SWIMMING POOL WATER TREATMENT SYSTEMS SURVEY C14 C14/255 MEDICAL GAS SUPPLY SYSTEMS SURVEY C14 C14/260 MEDICAL VACUUM SYSTEMS SURVEY C14 C14/265 MEDICAL ANAESTHETIC GAS SCAVENGING SYSTEMS SURVEY C14 C14/270 COMPRESSED AIR SUPPLY SYSTEMS SURVEY C14 C14/275 INSTRUMENT AIR SUPPLY SYSTEMS SURVEY C14 C14/280 NATURAL GAS SUPPLY CONNECTION SURVEY C14 C14/285 LIQUEFIED PETROLEUM GAS SUPPLY SYSTEMS SURVEY C14 C14/290 LABORATORY GAS SUPPLY SYSTEMS SURVEY C14 C14/295 BIOGAS SUPPLY SYSTEMS SURVEY C14 C14/300 PETROL AND DIESEL SUPPLY SYSTEMS SURVEY C14 C14/305 FUEL OIL SUPPLY SYSTEMS SURVEY C14 C14/310 LIQUID BIOFUEL SUPPLY SYSTEMS SURVEY C14 C14/315 STEAM AND CONDENSATE SYSTEMS SURVEY C14 C14/320 FIRE HOSE REEL SYSTEMS SURVEY C14 C14/325 DRY RISER SYSTEMS SURVEY C14 C14/330 WET RISER SYSTEMS SURVEY C14 C14/335 SPRINKLER SYSTEMS SURVEY C14 C14/340 DELUGE SYSTEMS SURVEY C14 C14/345 FIRE HYDRANT SYSTEMS SURVEY C14 C14/350 WATER MIST SYSTEMS SURVEY C14 C14/355 GASEOUS FIRE-EXTINGUISHING SYSTEMS SURVEY C14 C14/360 FOAM FIRE-FIGHTING SYSTEMS SURVEY C14 C14/365 HEATING SYSTEMS SURVEY C14 C14/370 COMBINED HEAT AND POWER SYSTEMS SURVEY C14 C14/375 HEAT PUMP SYSTEMS SURVEY C14 C14/380 COOLING SYSTEMS SURVEY C14 C14/385 COLD ROOM SYSTEMS SURVEY C14 C14/390 GENERAL MECHANICAL VENTILATION SYSTEMS SURVEY C14 C14/395 KITCHEN EXTRACT SYSTEMS SURVEY C14 C14/400 CAR PARK VENTILATION SYSTEMS SURVEY C14 C14/405 SMOKE AND HEAT CONTROL SYSTEMS SURVEY C14 C14/410 SAFETY CABINET AND FUME CUPBOARD EXTRACT SYSTEMS SURVEY C14 C14/415 INDUSTRIAL FUME EXTRACT SYSTEMS SURVEY C14 C14/420 HIGH VOLTAGE CONNECTION SURVEY C14 C14/425 HIGH VOLTAGE DISTRIBUTION SYSTEMS SURVEY C14 C14/430 LOW VOLTAGE CONNECTION SURVEY C14 C14/435 GENERATOR SYSTEMS SURVEY C14 C14/440 LOW VOLTAGE DISTRIBUTION SYSTEMS SURVEY C14 C14/445 SMALL POWER SYSTEMS SURVEY C14 C14/450 EARTHING AND BONDING SYSTEMS SURVEY C14 C14/455 GENERAL LIGHTING SYSTEMS SURVEY C14 C14/460 EMERGENCY LIGHTING SYSTEMS SURVEY C14 C14/463 EXTERNAL LIGHTING SYSTEMS SURVEY C14 C14/465 PUBLIC ADDRESS SYSTEMS SURVEY C14 C14/470 INDUCTION LOOP SYSTEMS SURVEY C14 C14/475 INFRARED LISTENING SYSTEMS SURVEY C14 C14/480 INCOMING TELECOMMUNICATIONS CONNECTION SURVEY C14 C14/483 TELECOMMUNICATIONS SYSTEM SURVEY C14 C14/485 DATA DISTRIBUTION SYSTEMS SURVEY C14 C14/487 TELEVISION AND RADIO DISTRIBUTION SYSTEMS SURVEY C14 C14/490 ACCESS CONTROL SYSTEMS SURVEY C14 C14/493 INTRUDER DETECTION AND ALARM SYSTEMS SURVEY C14 C14/495 CLOSED CIRCUIT TELEVISION SYSTEMS SURVEY C14 C14/500 FIRE DETECTION AND ALARM SYSTEM SURVEY C14 C14/503 VOICE ALARM SYSTEMS SURVEY C14 C14/505 ASSISTANCE CALL SYSTEMS SURVEY C14 C14/510 PATIENT CALL SYSTEMS SURVEY C14 C14/515 GAS DETECTION AND ALARM SYSTEMS SURVEY C14 C14/520 WATER LEAK DETECTION AND ALARM SYSTEMS SURVEY C14 C14/525 LIGHTNING PROTECTION SYSTEM SURVEY C14 C14/530 LIFTS SURVEY C14 C14/535 ESCALATORS AND MOVING WALK SYSTEMS SURVEY C14 C14/540 PLANT SPACE SURVEYS C14 C14/810 SURVEY REPORT C14 C20 DEMOLITION C C20/110 DESK STUDY/ SURVEY C20 C20/120 EXTENT OF DECONSTRUCTION/ DEMOLITION C20 C20/130 GROUNDWORKS C20 C20/140 BENCH MARKS C20 C20/150 FEATURES TO BE RETAINED C20 C20/210 SERVICES REGULATIONS C20 C20/220 LOCATION OF SERVICES C20 C20/230 SERVICES DISCONNECTION ARRANGED BY CONTRACTOR C20 C20/231 SERVICES DISCONNECTION ARRANGED BY EMPLOYER C20 C20/232 SERVICES DISCONNECTION ARRANGED BY EMPLOYER AND CONTRACTOR C20 C20/240 DISCONNECTION OF DRAINS C20 C20/250 LIVE FOUL AND SURFACE WATER DRAINS C20 C20/260 SERVICE BYPASS CONNECTIONS C20 C20/270 SERVICES TO BE RETAINED C20 C20/310 WORKMANSHIP C20 C20/320 GAS OR VAPOUR RISKS C20 C20/330 DUST CONTROL C20 C20/340 HEALTH HAZARDS C20 C20/350 ADJOINING PROPERTY C20 C20/360 STRUCTURES TO BE RETAINED C20 C20/370 PARTLY DEMOLISHED STRUCTURES C20 C20/380 DANGEROUS OPENINGS C20 C20/390 ASBESTOS-CONTAINING MATERIALS – KNOWN OCCURENCES C20 C20/391 ASBESTOS-CONTAINING MATERIALS – KNOWN OCCUREANCES C20 C20/410 UNFORSEEN HAZARDS C20 C20/420 OPEN BASEMENTS, ETC C20 C20/430 FILLING OF BASEMENTS, ETC C20 C20/442 SITE SURFACE AT COMPLETION C20 C20/450 SITE CONDITION AT COMPLETION C20 C20/510 CONTRACTOR’S PROPERTY C20 C20/511 EMPLOYER’S PROPERTY C20 C20/520 RECYCLED MATERIALS C20 C30 SHORING/ FACADE RETENTION C C30/110 TERMS USED IN FAÇADE RETENTION C30 C30/120 RETENTION STRUCTURE GENERALLY C30 C30/130 RAKING SHORES C30 C30/140 FLYING SHORES C30 C30/150 RETENTION STRUCTURE C30 C30/160 STRUCTURAL STEEL SPECIFICATION STANDARD C30 C30/170 CONCRETE C30 C30/180 TEMPORARY WORKS CO-ORDINATOR C30 C30/210 RETENTION STRUCTURE - CONTRACTOR DESIGNED C30 C30/215 RETENTION STRUCTURE - DESIGN PROVIDED C30 C30/220 RESPONSIBILITY - ADVANCE WORKS CONTRACT C30 C30/240 ADVANCE WORKS RETENTION STRUCTURE - ADOPTION C30 C30/250 RETENTION STRUCTURE - USE OF PERMANENT STRUCTURE C30 C30/260 ACCESS TO FAÇADE C30 C30/270 FOUNDATIONS FOR RETENTION STRUCTURE C30 C30/280 CONNECTIONS BETWEEN FAÇADE AND SUPPORT STRUCTURE C30 C30/360 THERMAL RANGE AND PREDICTED FAÇADE MOVEMENTS C30 C30/370 PREDICTED FAÇADE FOUNDATION MOVEMENTS C30 C30/380 STABILITY LOADS C30 C30/385 LOADS ON CONNECTIONS C30 C30/410 STRUCTURAL STEEL C30 C30/420 STRUCTURAL TIMBER C30 C30/430 SCAFFOLDING AND ACCESSORIES C30 C30/435 TIMBER SCAFFOLD BOARDS C30 C30/460 BONDED ANCHORS C30 C30/470 THREADED STEEL STUDDING C30 C30/480 LOADBEARING TIMBER WEDGES/ PACKS C30 C30/600 WORKMANSHIP C30 C30/640 ENABLING WORK C30 C30/650 FOUNDATIONS C30 C30/655 RETAINING WALLS C30 C30/660 ERECTING RETENTION STRUCTURE C30 C30/670 UNFORESEEN HAZARDS C30 C30/680 BONDED ANCHORS C30 C30/690 PLANNED MODIFICATIONS TO RETENTION STRUCTURE C30 C30/710 RETENTION STRUCTURE MAINTENANCE C30 C30/720 FAÇADE MAINTENANCE C30 C30/770 MAINTENANCE CERTIFICATES C30 C30/910 DISMANTLING RETENTION STRUCTURE C30 C30/920 REMOVAL OF TEMPORARY FOUNDATIONS C30 C30/930 COMPLETION CONDITION SURVEY C30 C30/940 REPAIRS TO FAÇADE C30 C30/950 COMPLETION C30 C40 CLEANING MASONRY/ CONCRETE C C40/110 SCOPE OF WORK C40 C40/120 RELATED REPAIR AND REMEDIAL WORKS C40 C40/142 REMOVAL OF FITTINGS C40 C40/160 PROTECTION C40 C40/175 CONTROL AND DISPOSAL OF WASH WATER AND DETRITUS C40 C40/180 COLD WEATHER C40 C40/190 CLEANING GENERALLY C40 C40/215 RECORD OF CLEANING WORKS C40 C40/230 TRIAL SAMPLES C40 C40/300 COMPATIBILITY OF CHEMICAL PRODUCTS C40 C40/312 SURFACE BIOCIDES C40 C40/322 ABRASIVE CLEANING EQUIPMENT C40 C40/332 WATER SPRAY (MOUNTED NOZZLES) C40 C40/342 PRESSURIZED WATER CLEANING EQUIPMENT C40 C40/352 STEAM CLEANING EQUIPMENT C40 C40/362 CHEMICAL AGENTS C40 C40/372 PLAIN POULTICES C40 C40/412 REMOVAL OF LOOSELY ADHERED DEPOSITS C40 C40/422 BIOCIDE APPLICATION C40 C40/432 TOOLING C40 C40/442 ABRASIVE BLOCKS C40 C40/452 ABRASIVES CLEANING C40 C40/462 WATER SPRAY CLEANING (MOUNTED NOZZLES) C40 C40/472 PRESSURIZED WATER CLEANING C40 C40/482 STEAM CLEANING C40 C40/495 TESTING PH VALUES FOR CHEMICAL CLEANING C40 C40/500 CHEMICAL CLEANING C40 C40/515 PLAIN POULTICING C40 C41 REPAIRING/ RENOVATING/ CONSERVING MASONRY C C41/110 SCOPE OF WORK C41 C41/120 SITE INSPECTION C41 C41/125 REMOVAL OF FITTINGS/ FIXTURES C41 C41/130 REMOVAL OF PLANT GROWTHS FROM MASONRY C41 C41/140 RECORD OF WORK C41 C41/150 POWER TOOLS C41 C41/155 PUTLOG SCAFFOLDING C41 C41/160 PROTECTION OF MASONRY UNITS AND MASONRY C41 C41/165 STRUCTURAL STABILITY C41 C41/170 DISTURBANCE TO RETAINED MASONRY C41 C41/180 WORKMANSHIP C41 C41/185 ADVERSE WEATHER C41 C41/190 CONTROL SAMPLES C41 C41/210 ADVANCE REGISTRATION C41 C41/215 MATERIAL SAMPLES C41 C41/220 RECORDING PROFILES C41 C41/230 INSPECTION OF DRAWINGS, TEMPLATES, CASTS, ETC C41 C41/240 STONE C41 C41/245 REPLACEMENT STONE UNITS C41 C41/250 STONE ORIENTATION C41 C41/255 ASHLAR BLOCKS/ DRESSINGS C41 C41/258 EXISTING TEMPLATES C41 C41/260 BRICKS C41 C41/265 SALVAGED AND SECOND HAND BRICKS C41 C41/275 REPLACEMENT TERRACOTTA UNITS C41 C41/280 PROPRIETARY FIXINGS C41 C41/281 FIXINGS C41 C41/285 BED JOINT REINFORCEMENT TO MASONRY C41 C41/310 DISMANTLING MASONRY FOR REUSE C41 C41/320 REBUILDING C41 C41/330 PREPARATION FOR REPLACEMENT MASONRY C41 C41/340 REPLACEMENT OF STONE C41 C41/350 STONE INSERTS C41 C41/355 STONE INSERTS C41 C41/360 TILE REPLACEMENT OF C41 C41/365 REPLACEMENT OF BRICKS C41 C41/375 REPLACEMENT OF TERRACOTTA C41 C41/385 LAYING REPLACEMENT MASONRY UNITS C41 C41/390 GROUTING JOINTS C41 C41/395 INSTALLING STONE INSERTS C41 C41/400 FILLING TERRACOTTA BLOCKS C41 C41/405 BONDED DOWELS C41 C41/410 CORRODED METAL FIXINGS C41 C41/415 STONE PINNINGS FOR RUBBLE STONEWORK C41 C41/420 TEMPORARY DISTANCE PIECES FOR JOINTS IN ASHLAR STONEWORK C41 C41/450 WEATHERING LEDGES AT JOINTS C41 C41/455 DESCALING STONE C41 C41/458 REDRESSING STONE C41 C41/510 PREPARATION FOR MORTAR REPAIRS C41 C41/515 REINFORCEMENT FOR MORTAR REPAIRS C41 C41/520 MORTAR REPAIRS C41 C41/530 PROPRIETARY MORTAR REPAIRS C41 C41/540 APPLYING MORTAR C41 C41/550 SCRAPED FINISH TO MORTAR REPAIRS C41 C41/555 FLOAT FINISH TO MORTAR REPAIRS C41 C41/610 MORTAR REPAIR OF CRACKS C41 C41/620 RESIN INJECTION REPAIR OF CRACKS C41 C41/630 TIES C41 C41/640 PINNING C41 C41/650 LATERAL RESTRAINT TIES C41 C41/655 SITE TESTING OF LATERAL RESTRAINT TIES C41 C41/665 LATERAL RESTRAINT STRAPS C41 C41/675 JOINT REINFORCEMENT C41 C41/690 MAKING GOOD TO INJECTION AND INSERTION HOLES C41 C41/692 MAKING GOOD TO TIE AND DOWEL INSERTION HOLES USING CORE DRILLED PLUGS C41 C41/710 PREPARATION FOR GROUTING C41 C41/712 FLUSHING OUT C41 C41/720 HAND GROUTING C41 C41/730 GRAVITY INJECTION GROUTING C41 C41/735 PUMPED INJECTION GROUTING C41 C41/740 APPLICATION OF GROUTING C41 C41/810 PREPARATION FOR REPOINTING C41 C41/820 POINTING C41 C41/830 INJECTION MORTAR POINTING C41 C41/840 POINTING WITH TOOLS/ IRONS C41 C41/850 POINTING WITH INJECTION MORTAR C41 C41/860 BRUSHED FINISH TO JOINTS C41 C42 REPAIRING/ RENOVATING/ CONSERVING CONCRETE C C42/105 INFORMATION REQUIRED WITH TENDER C42 C42/110 SURVEY REPORT C42 C42/123 CONTRACTOR'S DESIGN C42 C42/125 INVESTIGATIONS BY CONTRACTOR C42 C42/130 INVESTIGATIONS BY EMPLOYER'S CONSULTANT C42 C42/135 TEST RECORDS C42 C42/140 COORDINATION OF TEMPORARY WORKS C42 C42/150 CONCRETE REPLACEMENT REPAIRS C42 C42/155 CRACK REPAIRS C42 C42/160 MORTAR/ CONCRETE OVERLAYS C42 C42/165 PROTECTIVE COATINGS C42 C42/180 CONTRACTOR DESIGNED REPAIRS C42 C42/305 PROPRIETARY REPAIR SYSTEMS C42 C42/310 REPAIR MORTAR C42 C42/315 PROTECTIVE COATING TO REINFORCEMENT C42 C42/320 LEVELLING/ SMOOTHING COATS C42 C42/325 PROPRIETARY SPRAYED MORTAR/ CONCRETE C42 C42/330 PROPRIETARY SELF-COMPACTING CONCRETE FOR RECASTING C42 C42/335 PROPRIETARY CONCRETE FOR SMALL AREA REPAIRS C42 C42/340 CRACK/ VOID SEALING GROUTS C42 C42/345 PROTECTIVE COATINGS FOR CONCRETE C42 C42/350 IMPREGNATIONS FOR PROTECTING CONCRETE C42 C42/355 CORROSION INHIBITOR IMPREGNATIONS C42 C42/360 REINFORCEMENT GENERALLY C42 C42/365 REINFORCEMENT COUPLERS C42 C42/605 EXECUTION GENERALLY C42 C42/610 QUALITY CONTROL DURING APPLICATION OF REPAIR SYSTEM C42 C42/615 QUALITY CONTROL ON COMPLETED HARDENED REPAIR SYSTEM C42 C42/620 TRIAL SAMPLES C42 C42/625 REMOVAL OF FITTINGS/ ATTACHMENTS C42 C42/630 CLEANING CONCRETE SURFACES C42 C42/635 TEMPORARY SUPPORTS/ PROPPING C42 C42/640 EXTENT OF CONCRETE REMOVAL FOR REINFORCEMENT TREATMENT/ REPLACEMENT C42 C42/645 CLEANING REINFORCEMENT C42 C42/650 ADDING/ REPLACING REINFORCEMENT GENERALLY C42 C42/652 LAPPING REPLACEMENT/ ADDITIONAL REINFORCEMENT WITH EXISTING C42 C42/655 WELDING NEW REINFORCEMENT TO EXISTING C42 C42/660 PREPARATION OF CONCRETE SUBSTRATES C42 C42/665 FORMWORK FOR RECASTING C42 C42/670 GROUTING CRACKS/ VOIDS C42 C42/675 CURING CONCRETE/ MORTAR C42 C42/710 RECORD OF LOCATION/ EXTENT OF REPAIRS C42 C45 DAMP PROOF COURSE RENEWAL/ INSERTION C C45/110 PRECONTRACT SURVEY C45 C45/115 SURVEY AND REPORT C45 C45/135 ASSOCIATED WORK C45 C45/140 BEFORE DPC INSTALLATION C45 C45/150 REMOVAL OF EXTERNAL RENDER C45 C45/165 REPOINTING OF WALLS C45 C45/210 CHEMICAL INJECTION DPC SYSTEM C45 C45/220 CHEMICAL INJECTION DPC SYSTEM C45 C45/230 PHYSICAL INSERTION DPC SYSTEM C45 C45/250 MAKING GOOD TO EXPOSED INJECTION HOLES C45 C45/251 MAKING GOOD TO EXPOSED INJECTION HOLES C45 C45/260 GUARANTEE C45 C46 CAVITY WALL TIE RENEWAL/ INSERTION C C46/100 PRECONTRACT SURVEY OF EXISTING CAVITY WALLS C46 C46/105 SURVEY OF EXISTING CAVITY WALLS C46 C46/110 INSERTING CAVITY WALL TIES C46 C46/220 SAMPLES FOR REPAIRS TO EXTERNAL LEAF C46 C46/310 INITIAL SITE TESTING OF PROOF LOADS FOR WALL TIES C46 C46/315 PROOF LOAD TESTING OF WALL TIES DURING INSTALLATION C46 C46/330 INSTALLATION OF WALL TIES GENERALLY C46 C46/340 POSITIONING OF WALL TIES C46 C46/345 POSITIONING OF WALL TIES FOR MASONRY CLADDING TO TIMBER FRAME C46 C46/350 REMOVING MASONRY UNITS FOR REUSE C46 C46/355 REMOVING MASONRY UNITS C46 C46/360 CORE DRILLING MASONRY WITH RENDERED FINISH C46 C46/365 REMOVAL OF EXISTING WALL TIES FROM INTERNAL LEAF C46 C46/368 REMOVAL OF EXISTING WALL TIES FROM EXTERNAL LEAF C46 C46/370 MAKING GOOD OF CAVITY WALL INSULATION C46 C46/380 REPLACING MASONRY UNITS C46 C46/390 ISOLATING WALL TIES IN EXTERNAL LEAF C46 C46/400 MAKING GOOD OF INSERTION/ INSPECTION HOLES IN EXTERNAL LEAF C46 C46/410 MAKING GOOD OF EXTERNAL RENDER C46 C46/420 RETOUCHING DECORATIVE FINISHES TO EXTERNAL LEAF C46 C46/430 REPOINTING CRACKED JOINTS C46 C46/440 DOCUMENTATION C46 C51 REPAIRING/ RENOVATING/ CONSERVING TIMBER C C51/110 INSPECTION C51 C51/130 OPENING UP C51 C51/150 TIMBER PROCUREMENT C51 C51/160 TIMBER SUPPLIER C51 C51/210 TIMBER SECTION STRENGTHENING - INTERNAL REINFORCEMENT C51 C51/220 TIMBER SECTION REPAIR - INTERNAL REINFORCEMENT C51 C51/230 MEMBER STRENGTHENING - EXTERNAL REINFORCEMENT C51 C51/240 END REPAIRS - LAP C51 C51/250 TIMBER SECTION REPAIRS - EXTERNAL SPLICE C51 C51/260 JOINT STRENGTHENING - PLANAR INTERSECTIONS C51 C51/270 JOINT STRENGTHENING - RECTANGULAR INTERSECTIONS C51 C51/310 STRUCTURAL SOFTWOOD (GRADED DIRECT TO STRENGTH CLASS) C51 C51/320 STRUCTURAL SOFTWOOD (STRENGTH CLASS NOT SPECIFIED): C51 C51/330 STRUCTURAL HARDWOOD (GRADED DIRECT TO STRENGTH CLASS) C51 C51/340 STRUCTURAL HARDWOOD (STRENGTH CLASS NOT SPECIFIED) C51 C51/350 UNGRADED SOFTWOOD C51 C51/360 SOFTWOOD FOR JOINERY REPAIRS C51 C51/370 HARDWOOD FOR JOINERY REPAIRS C51 C51/380 STRUCTURAL PLYWOOD C51 C51/410 CARBON STEEL SECTIONS AND PLATES C51 C51/420 STAINLESS STEEL SECTIONS AND PLATES C51 C51/430 PROPRIETARY FRAMING ANCHORS AND CLEATS C51 C51/440 CARBON STEEL BOLT ASSEMBLIES C51 C51/450 STAINLESS STEEL BOLT ASSEMBLIES C51 C51/460 CONNECTOR ASSEMBLIES C51 C51/470 NAILS C51 C51/480 SCREWS C51 C51/490 COACH SCREWS C51 C51/510 CARBON STEEL DOWELS C51 C51/520 STAINLESS STEEL DOWELS C51 C51/530 NON FERROUS DOWELS C51 C51/540 RESIN GROUT/ ADHESIVE C51 C51/600 WORKMANSHIP C51 C51/610 TEMPORARY SUPPORTS/ PROPPING C51 C51/620 PROTECTION OF TIMBER AND WOOD COMPONENTS BEFORE AND DURING INSTALLATION C51 C51/630 MATERIAL SAMPLES C51 C51/640 PROTOTYPES C51 C51/650 DIMENSIONS GENERALLY C51 C51/660 CROSS SECTION DIMENSIONS OF STRUCTURAL SOFTWOOD AND HARDWOOD C51 C51/670 CROSS SECTION DIMENSIONS OF NONSTRUCTURAL SOFTWOOD AND HARDWOOD C51 C51/680 WARPING OF TIMBER C51 C51/690 PROCESSING TREATED TIMBER C51 C51/700 WOOD COMPONENTS - AS DELIVERED FINISH C51 C51/710 REUSE OF TIMBER SECTIONS/ WOOD COMPONENTS C51 C51/720 TEMPORARY REMOVAL AND REINSTATEMENT OF FITTINGS/ FIXTURES C51 C51/730 PARTIAL REMOVAL OF EXISTING DECORATIVE/ PROTECTIVE FINISH C51 C51/740 REMOVAL OF EXISTING DECORATIVE/ PROTECTIVE FINISH C51 C51/750 CLEANING DIRTY OR STAINED WOOD C51 C51/760 REPAIR OF MEMBERS - CUTTING OUT MEMBERS C51 C51/770 REPAIR OF COMPRESSION MEMBERS - PIECING IN C51 C51/780 REPAIR OF DISTORTED TIMBER MEMBERS C51 C51/790 PEGS FOR MORTISE AND TENON JOINTS IN STRUCTURAL TIMBER C51 C51/800 CONDITION OF DOWELS TO BE BONDED INTO TIMBER C51 C51/810 USE OF TOOTHED PLATE CONNECTORS C51 C51/820 MAKING CONNECTORED JOINTS C51 C51/830 CRITICAL DIMENSIONS FOR FASTENERS C51 C51/840 FIXING FRAMING ANCHORS AND CLEATS C51 C51/850 ADHESIVE JOINTS C51 C51/860 MOISTURE CONTENT CHECKING C51 C51/870 MOISTURE CONTENT TESTING C51 C51/910 MECHANICALLY FASTENED JOINTS C51 C51/920 DATING TIMBERS USED IN STRUCTURAL REPAIRS C51 C52 FUNGUS/ BEETLE ERADICATION C C52/105 PRECONTRACT SURVEY C52 C52/115 SURVEY AND REPORT C52 C52/120 ASSOCIATED WORK C52 C52/140 OPENING UP/ CUTTING OUT/ REMOVAL OF BUILDING FABRIC C52 C52/150 DRYING OUT OF BUILDING FABRIC C52 C52/162 PREPARATION GENERALLY FOR PRESERVATIVE/ FUNGICIDE TREATMENTS TO TIMBERS/ MASONRY C52 C52/210 DRY ROT C52 C52/220 WET ROT C52 C52/230 BEETLE INFESTATION C52 C52/240 SALVAGED MATERIALS C52 C52/310 TIMBER PRESERVATIVES/ MASONRY FUNGICIDES GENERALLY C52 C52/318 TIMBER PRESERVATIVE TREATMENT C52 C52/323 TIMBER PRESERVATIVE TREATMENT C52 C52/338 MASONRY FUNGICIDE TREATMENT C52 C52/343 MASONRY FUNGICIDE TREATMENT C52 C52/355 DRILLING TIMBER FOR INJECTION OF PRESERVATIVES C52 C52/390 GUARANTEE C52 C90 ALTERATIONS - SPOT ITEMS C C90/110 DESCRIPTIONS C90 C90/120 EMPLOYER'S PROPERTY C90 C90/130 RECYCLED MATERIALS C90 D GROUNDWORK D20 EXCAVATING AND FILLING D D20/110 SITE INVESTIGATION D20 D20/112 SITE INVESTIGATION REPORT D20 D20/145 VARIATIONS IN GROUND WATER LEVEL D20 D20/150 EXISTING SERVICES, FEATURES AND STRUCTURES D20 D20/164 TREE ROOTS D20 D20/166 TREE ROOT BARRIERS D20 D20/168 SITE CLEARANCE D20 D20/170 REMOVING SMALL TREES, SHRUBS, HEDGES AND ROOTS D20 D20/175 FELLING LARGE TREES D20 D20/180 CHIPPING AND SHREDDING D20 D20/220 STRIPPING TOPSOIL D20 D20/221 TREATING TOPSOIL D20 D20/225 HANDLING TOPSOIL D20 D20/240 ADJACENT EXCAVATIONS D20 D20/242 EXCAVATIONS ADJACENT TO EXISTING BACKFILLED TRENCHES D20 D20/244 EXCAVATIONS ADJACENT TO EXISTING FOUNDATIONS D20 D20/245 EXCAVATIONS ADJACENT TO EXISTING FOUNDATIONS - CONTRACTOR'S DESIGN D20 D20/246 EXCAVATIONS ADJACENT TO PILE SUPPORTED STRUCTURES D20 D20/248 BACKFILL TO EXCAVATIONS LOWER THAN FOUNDATION FORMATION LEVEL D20 D20/250 PERMISSIBLE DEVIATIONS FROM FORMATION LEVELS D20 D20/255 ACCURACY - LINEAR DIMENSIONS D20 D20/260 INSPECTING FORMATIONS D20 D20/265 INSPECTING FORMATIONS IN SAND AND GRAVEL D20 D20/267 INSPECTION OF FORMATIONS IN SHRINKABLE SOILS D20 D20/270 FOUNDATIONS GENERALLY D20 D20/275 FOUNDATION BEARING D20 D20/280 TRENCH FILL FOUNDATIONS D20 D20/283 FORMATIONS FOR PILE SUPPORTED STRUCTURES D20 D20/285 STEPS IN FOUNDATION FORMATIONS D20 D20/290 FOUNDATIONS IN MADE UP GROUND D20 D20/310 UNSTABLE GROUND D20 D20/320 RECORDED FEATURES D20 D20/330 UNRECORDED FEATURES D20 D20/335 NEW FOUNDATIONS CROSSING OLD FOUNDATIONS OR WALLS D20 D20/337 OLD FOUNDATIONS OR WALLS BENEATH NEW GROUND SUPPORTED SLAB D20 D20/350 EXISTING WATERCOURSES D20 D20/360 EXCESS EXCAVATION D20 D20/370 UNDERGROUND STRUCTURES IN LANDSCAPE AREAS D20 D20/410 EXCAVATED TOPSOIL STORAGE D20 D20/415 EXCAVATED TOPSOIL REMOVAL D20 D20/420 TOPSOIL STORAGE HEAPS D20 D20/421 TOPSOIL STORAGE HEAP TREATMENT D20 D20/441 SURPLUS SUBSOIL D20 D20/450 WATER D20 D20/454 GROUND WATER LEVEL, SPRING OR RUNNING WATER D20 D20/457 PUMPING D20 D20/460 PERMANENT DRAINAGE SYSTEM D20 D20/500 PROPOSED FILL MATERIALS D20 D20/510 HAZARDOUS, AGGRESSIVE OR UNSTABLE MATERIALS D20 D20/512 LIMITATION OF SULFATE CONTENT IN FILL MATERIALS D20 D20/520 FROST SUSCEPTIBILITY D20 D20/525 TESTING OF SUITABILITY OF FILL MATERIALS BEFORE START OF FILLING D20 D20/530 PLACING FILL D20 D20/535 COMPACTION GENERALLY D20 D20/540 BENCHING IN FILL D20 D20/550 GEOTEXTILE SHEET D20 D20/555 GEOGRIDS D20 D20/560 GEONETS D20 D20/571 GEOCELLS D20 D20/575 BURIED EROSION CONTROL GEOMATS D20 D20/580 BURIED EROSION CONTROL BIODEGRADABLE MESH D20 D20/585 EROSION CONTROL MATTRESSES D20 D20/590 ROCK ROLLS D20 D20/600 COIR D20 D20/610 COMPACTED FILLING FOR LANDSCAPE AREAS D20 D20/615 LOOSE TIP FILLING FOR LANDSCAPE AREAS D20 D20/617 HIGHWAYS AGENCY TYPE 1 UNBOUND MIXTURE D20 D20/618 HIGHWAYS AGENCY TYPE 2 UNBOUND MIXTURE D20 D20/620 SUBGRADE IMPROVEMENT LAYER (CAPPING) D20 D20/626 COMPACTED GENERAL FILL D20 D20/640 STARTER LAYER OF COMPACTED FILLING D20 D20/650 PROTECTION OF COMPACTED FILLING D20 D20/700 BACKFILLING AROUND FOUNDATIONS D20 D20/710 HARDCORE FILLING D20 D20/715 VENTING HARDCORE LAYER D20 D20/730 BLINDING D20 D20/750 COMPACTED CLAY LINING D20 D20/755 INSTALLATION OF COMPACTED CLAY LINING D20 D20/770 GEOCOMPOSITE GAS VENTING LAYER D20 D20/810 EXCAVATED SOIL TREATMENT D20 D20/820 IN SITU SOIL TREATMENT D20 D20/830 SOIL VAPOUR EXTRACTION D20 D20/840 PUMP AND TREAT SYSTEM D20 D20/850 COMPACTED GENERAL FILLING/ EARTHWORKS D20 D20/900 APPENDIX 6/1 - REQUIREMENTS FOR ACCEPTABILITY AND TESTING, ETC. OF EARTHWORKS MATERIALS D20 D20/905 APPENDIX 6/2 - REQUIREMENTS FOR DEALING WITH CLASS U1B AND U2 UNACCEPTABLE MATERIAL D20 D20/910 APPENDIX 6/3 - REQUIREMENTS FOR EXCAVATION, DEPOSITION, COMPACTION (OTHER THAN DYNAMIC COMPACTION) D20 D20/915 APPENDIX 6/4 - REQUIREMENTS FOR CLASS 3 MATERIAL D20 D20/920 APPENDIX 6/5 - GEOTEXTILES USED TO SEPARATE EARTHWORKS MATERIALS D20 D20/925 APPENDIX 6/6 - FILL TO STRUCTURES AND FILL ABOVE STRUCTURAL FOUNDATIONS D20 D20/930 APPENDIX 6/7- SUB-FORMATION AND CAPPING AND PREPARATION AND SURFACE TREATMENT OF FORMATION D20 D20/935 APPENDIX 6/8 - TOPSOILING D20 D20/940 APPENDIX 6/9 - EARTHWORK ENVIRONMENTAL BUNDS, LANDSCAPE AREAS, STRENGTHENED EMBANKMENTS D20 D20/945 APPENDIX 6/10 - GROUND ANCHORAGES, CRIB WALLING AND GABIONS D20 D20/950 APPENDIX 6/11 - SWALLOW HOLES AND OTHER NATURALLY OCCURRING CAVITIES AND DISUSED MINE WORKINGS D20 D20/955 APPENDIX 6/12 - INSTRUMENTATION AND MONITORING D20 D20/960 APPENDIX 6/13 - GROUND IMPROVEMENT D20 D20/965 APPENDIX 6/14 - LIMITING VALUES FOR POLLUTION OF CONTROLLED WATERS D20 D20/970 APPENDIX 6/15 - LIMITING VALUES FOR HARM TO HUMAN HEALTH AND THE ENVIRONMENT D20 D30 PILING D D30/110 PILING SPECIFICATION D30 D30/130 PILES D30 D30/140 PRECAST CONCRETE PILES D30 D30/150 STEEL BEARING PILES D30 D30/160 DRIVEN CAST-IN-PLACE PILES WITH PERMANENT CASING D30 D30/165 DRIVEN CAST-IN-PLACE PILES WITH TEMPORARY CASING D30 D30/170 BORED CAST-IN-PLACE PILES D30 D30/180 AUGURED CAST-IN-PLACE PILES D30 D30/185 SPECIAL CONSTRUCTION FOR TEST PILES D30 D30/190 REDUCTION OF PILE FRICTION D30 D30/195 PROTECTION AGAINST AGGRESSIVE GROUND/ GROUND WATER D30 D30/210 CONTRACTOR DESIGN D30 D30/220 DESIGN AND CONSTRUCTION D30 D30/222 EUROCODES D30 D30/230 GROUND INVESTIGATION D30 D30/240 ADDITIONAL GROUND INVESTIGATION D30 D30/250 PERFORMANCE CRITERIA FOR STRUCTURE TO BE SUPPORTED ON THE PILES D30 D30/260 SPECIFIED WORKING LOADS FOR PILES D30 D30/270 FOUNDATION WORKING LOADS D30 D30/280 PERFORMANCE SPECIFICATION CRITERIA FOR PILES D30 D30/285 DAMAGE TO ADJACENT STRUCTURES AND SERVICES D30 D30/290 BASIS FOR SETTING OUT D30 D30/300 COMMENCING SURFACE D30 D30/310 PILE LENGTH – PENETRATION D30 D30/320 PILE LENGTH – TOE LEVEL D30 D30/330 DRIVING RESISTANCE, DYNAMIC EVALUATION AND SET D30 D30/340 INSTALLATION TOLERANCES FOR PILES D30 D30/345 INSTALLATION TOLERANCES FOR PLUNGED COLUMNS D30 D30/410 HEAD PREPARATION D30 D30/420 PILE SHOES OR TOE REINFORCEMENT D30 D30/430 ADDITIONAL MARKING OF PILES D30 D30/440 PERMANENT CASING D30 D30/445 SLEEVES D30 D30/450 COATING D30 D30/460 PROPRIETARY COATING D30 D30/470 CONCRETE GENERALLY D30 D30/480 DESIGNED CONCRETE D30 D30/490 PRESCRIBED CONCRETE D30 D30/495 PROPRIETARY STEEL FIBRES D30 D30/500 MORTAR OR CEMENT GROUT WITH FILLER D30 D30/510 CEMENT GROUT D30 D30/530 REINFORCEMENT GENERALLY D30 D30/540 COVER TO REINFORCEMENT D30 D30/550 LAPS IN REINFORCEMENT D30 D30/560 PRESTRESSING TENDONS D30 D30/570 SONIC LOGGING DUCTS D30 D30/580 PLUNGE COLUMNS D30 D30/610 METHOD STATEMENT D30 D30/615 RECORDS AND SUBMISSION OF INFORMATION DURING THE WORKS D30 D30/617 ADDITIONAL SAMPLING AND TESTING OF MATERIALS D30 D30/620 WELDING PROCEDURE D30 D30/625 NON-DESTRUCTIVE TESTING OF WELDS D30 D30/630 PRELIMINARY PILES D30 D30/635 TRIAL DRIVES D30 D30/640 TRIAL BORES D30 D30/645 UPLIFT AND LATERAL DISPLACEMENT TRIALS D30 D30/650 PERFORMANCE OF WORKING PILES D30 D30/655 TESTING EXCAVATED MATERIAL D30 D30/660 EASING OF PILE DRIVABILITY D30 D30/665 PREBORING FOR PILES D30 D30/670 JETTING FOR PILES D30 D30/675 SUPPORT FLUID D30 D30/680 PROHIBITION OF SUPPORT FLUID D30 D30/685 EXCAVATED MATERIAL D30 D30/690 DISPOSAL OF PILE HEADS D30 D30/696 METHOD OF PLACING PILE FILLING D30 D30/700 PLACING FILLING IN DRY BORINGS AND CASINGS D30 D30/702 INSTALLATION OF PLUNGE COLUMNS D30 D30/705 MONITORING CONSTRUCTION OF AUGURED PILES D30 D30/710 INSTRUMENT FAILURE WHEN AUGURING PILES D30 D30/715 PRESSURE GROUTING D30 D30/720 PREPARATORY PREBORING FOR LOW FRICTION SLEEVING OR SURROUND D30 D30/725 SUPPORT TO PREBORED HOLE FOR LOW FRICTION SLEEVING OR SURROUND D30 D30/730 TRIAL OF FRICTION REDUCING METHOD D30 D30/745 TESTING MORTAR AND CEMENT GROUT D30 D30/750 TESTING SUPPORT FLUID D30 D30/755 PREPARATION OF PILE HEADS FOR INTEGRITY TESTING D30 D30/760 PILE INTEGRITY TESTING - GENERAL D30 D30/765 SONIC LOGGING D30 D30/770 DYNAMIC/ RAPID TESTING OF PILES D30 D30/780 AXIAL MAINTAINED LOAD TESTING OF PRELIMINARY PILES D30 D30/785 AXIAL MAINTAINED LOAD PROOF TESTING OF WORKING PILES D30 D30/787 PILE CONSTANT RATE OF PENETRATION (CRP) TEST D30 D30/795 PILE PRELIMINARY LATERAL LOADING TEST D30 D30/810 TIMING OF PILE TESTING D30 D30/815 REMOVAL OF TEMPORARY WORKS USED FOR TESTING D30 D30/825 WORK TO PILE HEADS AFTER TESTING D30 D30/830 INSTRUMENTATION FOR PILES D30 D30/840 INSTRUMENTATION MONITORING D30 D30/850 SURVEYING OF PILES CONTAINING INSTRUMENTATION D30 D30/910 HEALTH AND SAFETY FILE D30 D30/920 PILING GUARANTEE D30 D40 EMBEDDED RETAINING WALLS D D40/110 EMBEDDED RETAINING WALL SPECIFICATION D40 D40/115 GENERAL REQUIREMENTS FOR PILES D40 D40/130 EMBEDDED RETAINING WALL D40 D40/135 DIAPHRAGM WALLS D40 D40/145 SECANT WALLS D40 D40/175 CONTIGUOUS BORED PILE WALLS D40 D40/185 KING POST WALLS - BORED D40 D40/187 KING POST WALLS - DRIVEN D40 D40/195 STEEL SHEET PILE WALL D40 D40/210 CONTRACTOR DESIGN D40 D40/220 DESIGN PROVIDED D40 D40/222 EUROCODES D40 D40/230 GROUND INVESTIGATION D40 D40/240 ADDITIONAL GROUND INVESTIGATION D40 D40/250 PERFORMANCE CRITERIA FOR STRUCTURE TO BE SUPPORTED ON WALLS D40 D40/263 LOADS ON WALLS D40 D40/265 LOADS ON WALLS AND EXCAVATION DEPTHS D40 D40/266 LIMITS ON GROUND MOVEMENT DURING WALL INSTALLATION D40 D40/267 LIMITS ON GROUND MOVEMENTS DURING CONSTRUCTION D40 D40/268 LATERAL WALL MOVEMENT DURING EXCAVATION AND CONSTRUCTION D40 D40/275 PERFORMANCE CRITERIA FOR MOVEMENT UNDER VERTICAL LOAD D40 D40/283 PRELIMINARY TEST PILES D40 D40/285 DAMAGE TO ADJACENT STRUCTURES AND SERVICES D40 D40/290 BASIS FOR SETTING OUT D40 D40/300 COMMENCING SURFACE D40 D40/310 WALL PENETRATION D40 D40/320 WALL TOE LEVEL D40 D40/330 DRIVING RESISTANCE, DYNAMIC EVALUATION AND SET D40 D40/335 PRACTICAL REFUSAL D40 D40/340 INSTALLATION TOLERANCES FOR WALLS D40 D40/345 INSTALLATION TOLERANCES FOR PLUNGED KING POSTS D40 D40/350 WATER RESTRICTING CONSTRUCTION D40 D40/351 PERMANENT WATER EXCLUDING CONSTRUCTION D40 D40/352 WATER RESISTING STEEL PILE CONSTRUCTION D40 D40/353 WATER RESISTING JOINT AT TOP OF WALL D40 D40/355 WATER RESTRICTING CONTIGUOUS PILE CONSTRUCTION D40 D40/410 PILE HEAD PREPARATION D40 D40/420 PILE SHOES OR TOE REINFORCEMENT D40 D40/423 PROPRIETARY PRECAST CONCRETE D40 D40/425 PRECAST CONCRETE D40 D40/427 TIMBER LAGGING D40 D40/433 CAST IN PLACE PILES D40 D40/435 SECTION PROPERTIES OF STEEL KING POSTS D40 D40/437 SECTION PROPERTIES OF SHEET PILES D40 D40/438 SPECIAL SHEET PILES D40 D40/450 COATING D40 D40/460 PROPRIETARY COATING D40 D40/470 CONCRETE GENERALLY D40 D40/480 DESIGNED CONCRETE D40 D40/490 PRESCRIBED CONCRETE D40 D40/495 PROPRIETARY STEEL FIBRES D40 D40/500 CEMENT GROUT WITH FILLER D40 D40/510 CEMENT GROUT D40 D40/525 SELF HARDENING SLURRY MIX D40 D40/530 REINFORCEMENT GENERALLY D40 D40/540 COVER TO REINFORCEMENT D40 D40/550 LAPS IN REINFORCEMENT D40 D40/555 PROPRIETARY PREFORMED STOP ENDS D40 D40/565 PROPRIETARY WATERSTOPS D40 D40/570 SONIC LOGGING DUCTS D40 D40/575 BLIND ACCESS DUCTS D40 D40/610 METHOD STATEMENT D40 D40/612 CONTRACTOR DETAILING OF REINFORCEMENT D40 D40/615 RECORDS AND SUBMISSION OF INFORMATION DURING THE WORKS D40 D40/617 ADDITIONAL SAMPLING AND TESTING OF MATERIALS D40 D40/620 WELDING PROCEDURE D40 D40/625 NON-DESTRUCTIVE TESTING OF WELDS D40 D40/630 PRELIMINARY PILES/ BARRETTES D40 D40/635 TRIAL DRIVES D40 D40/640 TRIAL BORES D40 D40/655 TESTING EXCAVATED MATERIAL D40 D40/660 EASING OF DRIVABILITY D40 D40/665 PREBORING FOR KING POSTS D40 D40/670 JETTING D40 D40/675 SUPPORT FLUID D40 D40/680 PROHIBITION OF SUPPORT FLUID D40 D40/681 PLACING KING POST MEMEBERS D40 D40/683 INSTALLATION OF LAGGING UNITS D40 D40/685 EXCAVATED MATERIAL D40 D40/690 DISPOSAL OF PILE HEADS D40 D40/696 METHOD OF PLACING PILE FILLING D40 D40/700 PLACING FILLING IN DRY BORINGS AND CASINGS D40 D40/702 INSTALLATION OF PLUNGE KING POSTS D40 D40/704 MONITORING GENERALLY D40 D40/705 MONITORING CONSTRUCTION OF AUGERED PILES D40 D40/710 INSTRUMENT FAILURE WHEN AUGURING PILES D40 D40/715 PRESSURE GROUTING D40 D40/745 TESTING MORTAR AND CEMENT GROUT D40 D40/747 TESTING SELF HARDENING SLURRY MIX D40 D40/750 TESTING SUPPORT FLUID D40 D40/755 PREPARATION OF PILE HEADS FOR INTEGRITY TESTING D40 D40/760 INTEGRITY TESTING D40 D40/765 SONIC LOGGING D40 D40/830 INSTRUMENTATION D40 D40/840 INSTRUMENT MONITORING D40 D40/850 SURVEYING PILES/ WALLS CONTAINING INSTRUMENTATION D40 D40/860 TEMPORARY BACKFILL MATERIAL D40 D40/910 HEALTH AND SAFETY FILE D40 D40/920 PILING GUARANTEE D40 D41 CRIB WALLS/ GABIONS/ DRYSTACK MASONRY D D41/105 DESIGN AND CONSTRUCTION OF EARTH RETAINING STRUCTURE D41 D41/107 CONSTRUCTION OF EARTH RETAINING STRUCTURE D41 D41/109 EUROCODES D41 D41/110 TIMBER CRIB WALLS D41 D41/120 PRECAST REINFORCED CONCRETE CRIB WALLS D41 D41/130 ERECTING CRIB WALLS D41 D41/210 GABIONS D41 D41/215 TRAPIONS D41 D41/220 MATTRESSES D41 D41/230 BASTIONS D41 D41/240 GEOTEXTILE D41 D41/250 ASSEMBLING AND INSTALLING D41 D41/260 ASSEMBLING AND INSTALLING BASTIONS D41 D41/310 DRYSTACK INTERLOCKING MASONRY D41 D41/320 LAYING DRYSTACK INTERLOCKING MASONRY D41 D41/330 GEOGRID REINFORCEMENT D41 D41/410 PRECAST REINFORCED CONCRETE STEM WALLS D41 D41/420 PLACING PRECAST REINFORCED CONCRETE STEM WALLS D41 D41/510 TIMBER RETAINING WALL SYSTEMS D41 D41/520 TIMBER RETAINING WALLS D41 D41/550 ERECTING TIMBER RETAINING WALLS D41 D41/560 HARD LANDSCAPING MATERIALS SPECIFICATION D41 D45 SOIL NAILING D D45/10 INFORMATION TO BE PROVIDED WITH TENDER D45 D45/105 EUROCODES D45 D45/110 SOIL NAILING - CONTRACTOR DESIGN D45 D45/115 SOIL NAILING DESIGN D45 D45/117 METHOD STATEMENT D45 D45/118 SOIL NAIL TESTS - GENERAL D45 D45/120 PERFORMANCE CRITERIA - PULL OUT TEST OF SOIL NAILS D45 D45/122 PERFORMANCE CRITERIA - PROOF TEST OF SOIL NAILS FOR SUITABILITY D45 D45/123 PERFORMANCE CRITERIA - PROOF TEST OF SOIL NAILS FOR ACCEPTANCE D45 D45/125 PERFORMANCE OF PRODUCTION SOIL NAILS D45 D45/130 TOLERANCES FOR SOIL NAILS D45 D45/135 TOLERANCES FOR FACES OF NEW RETAINING WALLS D45 D45/137 TOLERANCE FOR EXCAVATED SURFACES D45 D45/145 GROUND INVESTIGATION D45 D45/150 ADDITIONAL GROUND INVESTIGATION D45 D45/2 TO BE READ WITH PRELIMINARIES/GENERAL CONDITIONS. D45 D45/210 METAL SOIL NAILS D45 D45/212 NON METALLIC SOIL NAILS D45 D45/215 MECHANICAL JOINTS IN SOLID STEEL BAR SOIL NAILS D45 D45/220 SOIL NAIL ANCHORAGE D45 D45/222 CORRUGATED PLASTICS DUCTS D45 D45/224 CENTRALIZERS D45 D45/225 BOREHOLES WITHOUT PERMANENT CASINGS FOR GROUTED SOIL NAILS D45 D45/230 DRIVEN PERMANENT STEEL CASINGS FOR GROUTED SOIL NAILS D45 D45/235 DRIVEN OR ROTATED SOIL NAILS D45 D45/237 SELF-DRILLED SOIL NAILS D45 D45/240 FLEXIBLE STRUCTURAL FACING D45 D45/242 SOFT FACING D45 D45/245 SPRAYED CONCRETE FACING D45 D45/247 CAST CONCRETE FACING D45 D45/250 PROPRIETARY PRECAST CONCRETE FACING D45 D45/255 PRECAST CONCRETE FACING D45 D45/260 JOINTS IN CONCRETE FACING D45 D45/310 FACING DRAINAGE D45 D45/312 WEEP HOLES D45 D45/315 DEEP DRAINAGE D45 D45/320 THICKNESS MEASURING PINS FOR SPRAYED CONCRETE FINISH D45 D45/330 CEMENT GROUT D45 D45/610 EXCAVATION AND SOIL FACE PREPARATION D45 D45/612 BOREHOLE SUPPORT FLUID D45 D45/615 PRE INSTALLATION OF NAILS IN PLASTIC DUCT ENCAPSULATION D45 D45/620 INSTALLATION OF SOIL NAILS GROUTED INTO BOREHOLES D45 D45/622 INSTALLATION OF SIMULTANEOUSLY GROUTED SOIL NAILS AND DUCTS INTO BOREHOLES D45 D45/625 INSTALLATION OF SOIL NAILS GROUTED INTO DRIVEN CASINGS D45 D45/627 INSTALLATION OF SELF DRILLING, GROUTED NAILS D45 D45/630 INSTALLATION OF DRIVEN SOIL NAILS D45 D45/710 SOIL FACE STABILITY TEST D45 D45/715 TESTING CEMENT GROUT D45 D45/719 TESTING BOREHOLE SUPPORT FLUID D45 D45/732 PREPARATION OF TEST SOIL NAILS D45 D45/735 PROCEDURE FOR TESTING SOIL NAILS D45 D45/740 PULL OUT TESTS FOR SOIL NAILS D45 D45/745 ACCEPTANCE TESTS FOR SOIL NAILS D45 D45/910 RECORDS OF SOIL NAILS D45 D45/915 RECORDS OF BOREHOLES D45 D50 UNDERPINNING D D50/10 INFORMATION TO BE PROVIDED WITH TENDER D50 D50/110 UNDERPINNING - CONTRACTOR DESIGN D50 D50/115 UNDERPINNING DESIGN AND CONSTRUCTION D50 D50/117 EUROCODES D50 D50/120 PILING SPECIFICATION D50 D50/125 PILE PERFORMANCE TESTS D50 D50/130 PERFORMANCE SPECIFICATION CRITERIA FOR PILES D50 D50/135 PILE WORKING PERFORMANCE D50 D50/137 PILE COMMENCING SURFACE D50 D50/140 PILE LENGTH - PENETRATION D50 D50/145 PILE LENGTH - TOE LEVEL D50 D50/150 PILE DRIVING RESISTANCE, DYNAMIC EVALUATION AND SET D50 D50/155 GROUND INVESTIGATION D50 D50/160 ADDITIONAL GROUND INVESTIGATION D50 D50/165 EXPLORATORY HOLES D50 D50/170 DISCONNECTION OF SERVICES IN WORKING AREAS D50 D50/210 CONTINUOUS MASS CONCRETE UNDERPINNING D50 D50/215 INTERMITTENT MASS CONCRETE UNDERPINNING D50 D50/220 BEAM AND MASS CONCRETE PIER UNDERPINNING D50 D50/225 RAKING PILE SUPPORT DIRECT TO EXISTING STRUCTURE D50 D50/230 JACKED PILE SUPPORT DIRECT TO EXISTING STRUCTURE D50 D50/235 PILE SUPPORT DIRECT TO EXISTING STRUCTURE WITH CANTILEVERED KNUCKLE D50 D50/240 PILE UNDERPINNING WITH REINFORCED CONCRETE SUPPORTING STRUCTURE D50 D50/245 UNDERPINNING WITH JET GROUTING D50 D50/250 UNDERPINNING WITH GROUT D50 D50/310 PILES D50 D50/315 PRECAST CONCRETE DISPLACEMENT PILES D50 D50/320 STEEL DISPLACEMENT PILES D50 D50/325 CAST-IN-PLACE CASED DISPLACEMENT PILES D50 D50/330 CAST-IN-PLACE CONCRETE SHELL DISPLACEMENT PILES D50 D50/335 JACKING PILES D50 D50/340 BORED CAST-IN-PLACE REPLACEMENT PILES D50 D50/345 AUGERED CAST-IN-PLACE REPLACEMENT PILES D50 D50/350 ADDITIONAL MARKING OF PREFORMED PILES AND PILE SEGMENTS D50 D50/355 SUPPORT FLUID D50 D50/357 PROHIBITION OF SUPPORT FLUID D50 D50/360 PERMANENT CASINGS D50 D50/365 FRICTION REDUCING SLEEVE TO UPPER LENGTH OF PILES D50 D50/370 PLACING FILLING IN DRY BORINGS AND CASINGS D50 D50/375 COVER TO PILE REINFORCEMENT D50 D50/410 PRECAST CONCRETE BEAMS D50 D50/415 STEEL BEAMS/ NEEDLES D50 D50/417 COATING FOR STEEL D50 D50/418 PROPRIETARY COATING FOR STEEL D50 D50/420 IN SITU CONCRETE WALL BEAMS D50 D50/425 STEEL STOOLS D50 D50/430 HEAVE PROTECTION D50 D50/435 IN SITU CONCRETE D50 D50/440 MAKING CONCRETE GENERALLY D50 D50/445 DESIGNATED CONCRETE D50 D50/450 DESIGNED CONCRETE FOR PILE FILLING D50 D50/455 PRESCRIBED CONCRETE FOR PILE FILLING D50 D50/460 MORTAR OR CEMENT GROUT WITH FILLER D50 D50/465 CEMENT GROUT D50 D50/470 UNDERPINNING GROUT D50 D50/472 PROPRIETARY STEEL FIBRES D50 D50/475 STEEL REINFORCEMENT GENERALLY D50 D50/480 PREFABRICATED REINFORCEMENT D50 D50/610 REPAIR OF MASONRY D50 D50/615 CONSTRUCTION OF MASS CONCRETE UNDERPINNING D50 D50/620 CONSTRUCTION OF INTERMITTENT MASS CONCRETE UNDERPINNING/ UNDERPINNING PIERS D50 D50/625 INSTALLATION OF RAKING PILES THROUGH WALL/ FOUNDATION D50 D50/630 INSTALLATION OF JACKED PILES BENEATH EXISTING FOUNDATION D50 D50/635 INSTALLATION OF PILES JACKED D50 D50/640 INSTALLATION OF PILES WITH CANTILEVERED KNUCKLE D50 D50/645 EASING PILE DRIVING D50 D50/650 PREBORING FOR PILES D50 D50/655 JETTING FOR PILES D50 D50/660 INSTALLATION OF PILE PERMANENT CASING/ FRICTION REDUCERS D50 D50/665 INSTALLATION OF PILE FRICTION REDUCERS - DISPLACEMENT PILES D50 D50/670 INSTALLATION OF PILE FRICTION REDUCERS - REPLACEMENT PILES WITHOUT TEMPORARY CASING D50 D50/675 INSTALLATION OF PILE FRICTION REDUCERS - REPLACEMENT PILES WITH TEMPORARY CASING D50 D50/680 INSTALLATION OF PRECAST CONCRETE WALL BEAMS D50 D50/685 INSTALLATION OF STEEL BEAMS D50 D50/690 UNDERPINNING WITH GROUT D50 D50/710 TESTING MORTAR/ CEMENT GROUT D50 D50/715 TESTING SUSPENSION/ CHEMICAL GROUT D50 D50/717 TESTING SUPPORT FLUID D50 D50/720 SUBSOIL INVESTIGATION FOR GROUT UNDERPINNING D50 D50/725 IN SITU TESTING OF UNTREATED/ TREATED SOIL D50 D50/730 LABORATORY TESTING OF UNTREATED/ TREATED SOIL D50 D50/735 PREPARATION OF PILE HEADS FOR TESTING D50 D50/740 INTEGRITY TESTING OF PILES D50 D50/745 AXIAL MAINTAINED LOAD TESTING OF PRELIMINARY PILES D50 D50/747 AXIAL MAINTAINED LOAD PROOF TESTING OF WORKING PILES D50 D50/750 WORK TO HEADS OF WORKING PILES AFTER TESTING D50 D50/760 MATERIALS TESTING LABORATORY D50 D50/910 HEALTH AND SAFETY FILE - MASS CONCRETE UNDERPINNING D50 D50/915 HEALTH AND SAFETY FILE - PILING D50 D50/920 HEALTH AND SAFETY FILE - GROUTING D50 D50/925 PILING GUARANTEE D50 E IN SITU CONCRETE/LARGE PRECAST CONCRETE E05 IN SITU CONCRETE CONSTRUCTION GENERALLY E E05/210 CONTRACTOR'S STRUCTURAL DESIGN E05 E05/215 CONTRACTOR'S STRUCTURAL DETAILING OF REINFORCEMENT E05 E05/220 STRUCTURAL DESIGN PROVIDED E05 E05/223 STRUCTURAL DRAWINGS AND SCHEDULES E05 E05/225 TEMPERATURE RECORDS E05 E05/235 OPENINGS, INSERTS AND FIXINGS E05 E05/250 STRUCTURAL TESTING E05 E05/290 ACCURACY OF CONSTRUCTION E05 E05/300 LEVELS OF STRUCTURAL CONCRETE FLOORS E05 E05/310 SURFACE REGULARITY OF CONCRETE FLOORS TO BS 8204 - GENERAL E05 E05/315 SURFACE REGULARITY OF CONCRETE FLOORS TO BS 8204 - TOLERANCE CLASS E05 E05/318 SURFACE REGULARITY OF CONCRETE FLOORS TO TR 34 - GENERAL AND TOLERANCE E05 E05/320 TOLERANCES AND SURFACE REGULARITY OF SPRAYED CONCRETE E05 E05/410 IN SITU CONCRETE CONSTRUCTION - SUPERVISION/ CHECKING E05 E05/420 WATER RESISTANT CONCRETE CONSTRUCTION E05 E05/430 SURFACE CRACKING E05 E05/450 INSPECTION OF WATER EXCLUDING STRUCTURES E05 E05/460 TESTING OF WATER RETAINING STRUCTURES E05 E05/470 TESTING OF ELEVATED WATER RETAINING STRUCTURES E05 E05/610 SPECIALLY CONSTRUCTED SAMPLE E05 E10 MIXING/CASTING/CURING IN SITU CONCRETE E E10/101 SPECIFICATION E10 E10/105 DESIGNATED CONCRETE E10 E10/110 BASIC DESIGNATED CONCRETE E10 E10/125 SUBSTITUTION OF STANDARDIZED PRESCRIBED CONCRETE FOR DESIGNATED CONCRETE E10 E10/132 DESIGNED CONCRETE E10 E10/150 PRESCRIBED CONCRETE E10 E10/160 STANDARDIZED PRESCRIBED CONCRETE E10 E10/170 PROPRIETARY SELF COMPACTING CONCRETE E10 E10/181 PROPRIETARY HIGH STRENGTH CONCRETE E10 E10/185 PRE-BLENDED CONCRETE E10 E10/190 FOAMED CONCRETE E10 E10/193 FOAMED CONCRETE - PERFORMANCE E10 E10/215 READY-MIXED CONCRETE E10 E10/218 SITE MIXED CONCRETE E10 E10/221 INFORMATION ABOUT PROPOSED CONCRETES E10 E10/225 CHANGES TO SPECIFICATION E10 E10/230 INTERRUPTION OF SUPPLY DURING CONCRETING E10 E10/310 RECYCLED AGGREGATE E10 E10/312 PROPRIETARY AGGREGATE E10 E10/315 AGGREGATES FOR EXPOSED VISUAL CONCRETE E10 E10/325 MATERIALS FOR EXPOSED VISUAL CONCRETE E10 E10/415 ADMIXTURES E10 E10/418 PROPRIETARY ADMIXTURE E10 E10/425 PROPRIETARY STEEL FIBRES E10 E10/427 STEEL FIBRES E10 E10/429 POLYMER FIBRES E10 E10/430 PIGMENTS FOR COLOURED CONCRETE E10 E10/490 PROPERTIES OF FRESH CONCRETE E10 E10/505 PROJECT TESTING OF CONCRETE - GENERAL E10 E10/507 INITIAL PROJECT TESTING OF CONCRETE E10 E10/508 REGULAR PROJECT TESTING OF CONCRETE E10 E10/520 TESTING LABORATORY E10 E10/530 TESTS RESULTS E10 E10/550 BROKEN CUBES FROM FAILED STRENGTH TESTS E10 E10/610 CONSTRUCTION/ SEQUENCE/ TIMING REQUIREMENTS E10 E10/620 TEMPERATURE OF CONCRETE E10 E10/630 PREMATURE WATER LOSS E10 E10/635 CONSTRUCTION JOINTS NOT PERMITTED E10 E10/640 CONSTRUCTION JOINTS E10 E10/645 SPACING OF CONSTRUCTION JOINTS E10 E10/648 ADVERSE TEMPERATURE CONDITIONS E10 E10/650 SURFACES TO RECEIVE CONCRETE E10 E10/660 INSPECTION OF SURFACES E10 E10/670 TRANSPORTING E10 E10/680 PLACING E10 E10/690 COMPACTING E10 E10/700 LIGHTWEIGHT AGGREGATE CONCRETE E10 E10/720 VIBRATORS E10 E10/730 PLASTIC SETTLEMENT E10 E10/810 CURING GENERALLY E10 E10/811 COVERINGS FOR CURING E10 E10/812 PREVENTING EARLY AGE THERMAL CRACKING E10 E10/815 ADDITIONAL CURING REQUIREMENT - WATER CURING E10 E10/817 CURING CLASS E10 E10/818 CURING PERIODS GENERALLY E10 E10/820 CURING PERIODS E10 E10/840 PROTECTION E10 E11 SPRAYED IN SITU CONCRETE E E11/110 SPRAYED CONCRETE E11 E11/120 SPRAYED CONCRETE ENCASEMENT TO STRUCTURAL STEELWORK E11 E11/130 SPRAYED FLASH/ FINISHING COAT E11 E11/140 SPRAYED CONCRETE SPECIFICATION E11 E11/160 CONCRETE SPECIFICATION CHANGES E11 E11/170 QUALIFICATIONS OF NOZZLEMAN E11 E11/240 INFORMATION ABOUT PROPOSED CONCRETE E11 E11/410 DESIGNED CONCRETE E11 E11/415 PRESCRIBED CONCRETE E11 E11/420 AGGREGATE FOR EXPOSED VISUAL E11 E11/435 PROPRIETARY ADMIXTURE E11 E11/437 PROPRIETARY AGGREGATE E11 E11/440 FLASH/ FINISHING COAT E11 E11/450 PROPRIETARY STEEL FIBRES E11 E11/460 STEEL FIBRES E11 E11/470 POLYMER FIBRES E11 E11/480 SUBSTITUTION OF PRESCRIBED FOR DESIGNED CONCRETE E11 E11/490 FACTORY BLENDED DRY MIX E11 E11/500 READY-MIXED CONCRETE E11 E11/510 SITE MIXED CONCRETE E11 E11/520 DEVICES FOR ALIGNMENT CONTROL E11 E11/530 FIXINGS TO CONCRETE/ MASONRY SUBSTRATE E11 E11/540 BONDED ANCHORS FOR FIXINGS TO E11 E11/550 EXPANSION ANCHORS FOR FIXINGS TO E11 E11/560 FIXINGS TO STEEL SUBSTRATE E11 E11/610 CONSTRUCTION/ SEQUENCE/ TIMING REQUIREMENTS E11 E11/620 TEMPERATURE OF WATER RESISTANT CONCRETE E11 E11/630 CONSTRUCTION JOINTS E11 E11/640 PREMATURE WATER LOSS E11 E11/650 PREPARATION OF CONCRETE SUBSTRATE E11 E11/660 PREPARATION OF MASONRY SUBSTRATE E11 E11/670 PREPARATION OF SOIL SUBSTRATE E11 E11/680 SURFACES TO RECEIVE CONCRETE E11 E11/690 STEELWORK SURFACES TO RECEIVE CONCRETE E11 E11/700 INSPECTION OF SURFACES E11 E11/710 INSTALLING MECHANICAL ANCHORS E11 E11/720 INSTALLING BONDED ANCHORS E11 E11/730 PLACING OF SPRAYED CONCRETE E11 E11/740 PLACING OF FLASH OR FINISHING COAT E11 E11/750 CURING CONCRETE E11 E11/760 COVERINGS FOR CURING E11 E11/770 ADDITIONAL CURING REQUIREMENT – WATER CURING E11 E11/780 CURING PERIODS GENERALLY E11 E11/782 CURING PERIODS E11 E11/785 MINIMUM PERIODS FOR CURING AND FROST PROTECTION E11 E11/790 PROTECTION E11 E11/810 SOIL FACE STABILITY TESTING E11 E11/815 TESTING LABORATORY AND REPORTS E11 E11/817 PRODUCTION CONTROL E11 E11/820 TESTING SPRAYED CONCRETE – GENERAL E11 E11/830 PRECONSTRUCTION TESTING OF SPRAYED CONCRETE E11 E20 FORMWORK FOR IN SITU CONCRETE E E20/110 LOADINGS E20 E20/120 FORMWORK DETAILS E20 E20/132 PROPPING E20 E20/145 PERMANENT FORMWORK E20 E20/160 CAMBERS E20 E20/170 WORK BELOW GROUND E20 E20/172 FIXING PERMANENT STEEL SHUTTERING E20 E20/174 USE OF PERMANENT STEEL SHUTTERING AS WORKING PLATFORM E20 E20/176 TEMPORARY SUPPORTS TO PROFILED STEEL SHEETS E20 E20/178 FORMATION OF OPENINGS IN COMPOSITE ACTION SLABS E20 E20/180 COLLAPSIBLE BOARD SUBSTRUCTURE FORMWORK (COLLAPSED BY WETTING) E20 E20/182 COLLAPSIBLE BOARD SUBSTRUCTURE FORMWORK E20 E20/185 COMPRESSIBLE BOARD SUBSTRUCTURE FORMWORK E20 E20/190 SUBSTRUCTURE FORMWORK FOR GROUND BEAMS AND PILE CAPS E20 E20/195 VENTILATED SUBSTRUCTURE FORMWORK E20 E20/200 PROPRIETARY UNDERSLAB INSULATION E20 E20/215 UNDERSLAB INSULATION E20 E20/220 PERMANENT INSULATION FORMWORK (PIF) SYSTEM FOR WALLS E20 E20/225 PERMANENT FORMWORK FOR SUSPENDED FLOORS E20 E20/310 ACCURACY E20 E20/315 SUBSTRUCTURE FORMWORK AND UNDERSLAB INSULATION E20 E20/320 JOINTS IN FORMS E20 E20/330 INSERTS, HOLES AND CHASES E20 E20/340 KICKERS E20 E20/350 FORM TIES E20 E20/351 PROHIBITION OF FORM TIES E20 E20/360 PROPRIETARY FORM TIES FOR WATER RESISTANT CONCRETE E20 E20/361 FORM TIES FOR WATER RESISTANT CONCRETE E20 E20/380 VOID FORMERS E20 E20/390 COFFER UNITS E20 E20/400 TROUGH UNITS E20 E20/405 COLUMN SHUTTERS E20 E20/410 EXPANDED STEEL MESH FORMWORK LINING E20 E20/420 RIBBED STEEL MESH FORMWORK AND REINFORCEMENT E20 E20/435 PERMANENT FORMWORK LININGS E20 E20/470 RELEASE AGENTS E20 E20/480 SURFACE RETARDERS E20 E20/510 STRIKING FORMWORK E20 E20/521 MINIMUM PERIOD FOR RETAINING FORMWORK/ TEMPORARY SUPPORTS IN POSITION E20 E20/600 SAMPLES OF FINISHES AVAILABLE FOR INSPECTION E20 E20/605 CONTROL SAMPLES (PART OF THE FINISHED WORK) E20 E20/610 BASIC FINISH E20 E20/613 ORDINARY FINISH E20 E20/615 FINISH TO RECEIVE ASPHALT TANKING E20 E20/620 PLAIN FINISH E20 E20/630 SPECIAL FINISH E20 E20/635 STANDARD FINISH E20 E20/640 ROUGH BOARD FINISH E20 E20/650 RIBBED FINISH E20 E20/660 PROPRIETARY FORM LINING FINISH E20 E20/665 CONTROLLED PERMEABILITY FORM LINING FINISH E20 E20/700 FINISH FOR ABRASIVE BLASTING E20 E20/710 FINISH FOR TOOLING E20 E20/750 ARRISES, MARGINS AND JUNCTIONS E20 E30 REINFORCEMENT FOR IN SITU CONCRETE E E30/110 QUALITY ASSURANCE OF REINFORCEMENT E30 E30/140 PLAIN BAR REINFORCEMENT E30 E30/150 RIBBED BAR REINFORCEMENT E30 E30/160 GALVANIZED STEEL REINFORCEMENT E30 E30/170 STAINLESS STEEL PLAIN BAR REINFORCEMENT E30 E30/180 STAINLESS STEEL RIBBED BAR REINFORCEMENT E30 E30/210 STANDARD FABRIC REINFORCEMENT E30 E30/240 PROPRIETARY PREFABRICATED REINFORCEMENT E30 E30/245 PREFABRICATED REINFORCEMENT E30 E30/250 PROPRIETARY PREFABRICATED CONTINUITY REINFORCEMENT STRIPS E30 E30/255 PREFABRICATED CONTINUITY REINFORCEMENT STRIPS E30 E30/260 PROPRIETARY MECHANICAL COUPLERS E30 E30/265 MECHANICAL COUPLERS E30 E30/310 CUTTING AND BENDING REINFORCEMENT E30 E30/320 PROTECTION OF REINFORCEMENT E30 E30/410 LAPS OR SPLICES E30 E30/425 LAPS NOT DETAILED ON DRAWINGS E30 E30/427 LAPS IN FABRIC REINFORCEMENT E30 E30/430 WELDING REINFORCEMENT E30 E30/451 FIXING REINFORCEMENT E30 E30/454 FIXING REINFORCEMENT FOR SPRAYING CONCRETE E30 E30/470 TOLERANCES ON COVER E30 E30/480 NOMINAL COVER TO REINFORCEMENT E30 E30/510 RUST STAINING E30 E30/520 COVER METER SURVEY E30 E30/521 COVER METER FOR USE BY OTHERS E30 E40 DESIGNED JOINTS IN IN SITU CONCRETE E E40/120 CONSTRUCTION/ MOVEMENT JOINTS GENERALLY E40 E40/132 ADDITIONAL CONSTRUCTION JOINTS E40 E40/210 FORMED JOINTS E40 E40/211 FORMED JOINTS IN CONCRETE WEARING SURFACES E40 E40/220 PRECAST CONCRETE PERMANENT SIDE FORMS E40 E40/230 PREPARATION OF CONSTRUCTION JOINTS E40 E40/240 BOTTOM OF SLAB CRACK INDUCERS E40 E40/250 INSERTED STRIP CRACK INDUCERS E40 E40/260 SAWN CRACK INDUCING GROOVES E40 E40/310 FLEXIBLE WATERSTOPS E40 E40/320 HYDROPHILIC WATERSTOPS E40 E40/410 CARBON STEEL TIE BARS E40 E40/415 STAINLESS STEEL TIE BARS E40 E40/420 FABRIC TIE STRIPS E40 E40/430 CARBON STEEL DOWEL BARS E40 E40/435 STAINLESS STEEL DOWEL BARS E40 E40/440 LOAD TRANSFER SYSTEMS E40 E40/510 SHEET MEMBRANE FOR SLIDING JOINTS E40 E40/520 SHEET JOINT FILLER E40 E40/530 SEALANT E40 E40/545 COMPRESSIBLE SEALING STRIP SYSTEM E40 E40/590 INSPECTION OF TIED AND PARTIALLY TIED JOINTS E40 E41 WORKED FINISHES TO IN SITU CONCRETE E E41/110 MONOLITHIC CONCRETE WEARING SCREED E41 E41/140 SAMPLES AVAILABLE FOR INSPECTION E41 E41/145 CONTROL SAMPLES E41 E41/150 FINISHING E41 E41/210 TAMPED FINISH E41 E41/220 SCORED FINISH E41 E41/230 BRUSHED FINISH E41 E41/240 WOOD FLOATED FINISH E41 E41/310 SMOOTH FLOATED FINISH E41 E41/320 TROWELLED FINISH E41 E41/330 TROWELLED FINISH FOR WEARING SURFACES E41 E41/335 DRY SHAKE TROWELLED FINISH FOR WEARING SURFACES E41 E41/340 DEWATERED TROWELLED FINISH FOR WEARING SURFACES E41 E41/410 POWER GROUND FINISH FOR WEARING SURFACES E41 E41/420 ABRASIVE BLASTED FINISH E41 E41/430 TOOLED FINISH E41 E41/510 SURFACE HARDENER E41 E41/520 SURFACE SEALER E41 E41/530 SLIP RESISTANCE TESTING OF WEARING SURFACES E41 E42 ACCESSORIES CAST INTO IN SITU CONCRETE E E42/110 ACCESSORIES SPECIFIED ELSEWHERE E42 E42/310 HOLDING DOWN SYSTEMS E42 E42/320 CAST-IN SOCKETS E42 E42/330 ANCHOR BOLTS E42 E42/335 SHEAR LOAD CONNECTORS E42 E42/340 CHANNELS AND SLOTS E42 E42/345 ANCHOR PLATES/ COLUMN SHOES E42 E42/350 PROPRIETARY CORNER GUARDS E42 E42/360 CORNER GUARDS E42 E42/370 FABRICATED EDGE STRIPS AND FRAMES E42 E42/380 DUCTS E42 E42/390 GALVANIZED COATINGS E42 E42/395 SHERARDIZED COATINGS ON METAL FASTENERS E42 E42/610 HOLLOW ACCESSORIES E42 E42/620 TEMPORARY SUPPORTS E42 E42/630 PROTECTIVE COATINGS E42 E42/640 INSTALLATION E42 E60 PRECAST/ COMPOSITE CONCRETE FLOORS/ ROOF DECKS E E60/110 PRECAST BEAM AND BLOCK E60 E60/130 PRECAST SLAB E60 E60/140 PRECAST FLOOR PLATE E60 E60/180 PRECAST STAIRS E60 E60/210 FLOOR E60 E60/220 ROOF DECK E60 E60/240 DETAILING OF PROPRIETARY SYSTEM E60 E60/250 CONTRACTOR'S STRUCTURAL DESIGN E60 E60/290 STANDARD PRECAST CONCRETE INFILL BLOCKS E60 E60/295 AUTOCLAVED AERATED CONCRETE INFILL BLOCKS E60 E60/297 PROPRIETARY INFILL BLOCKS E60 E60/315 INFILLING BEAM BEARINGS E60 E60/320 CONCRETE INFILL E60 E60/325 GROUTING E60 E60/330 EXPANDED POLYSTYRENE VOID FORMERS E60 E60/340 LATERAL RESTRAINT STRAPS E60 E60/345 IN SITU CONCRETE TOPPING E60 E60/350 LEVELS OF STRUCTURAL CONCRETE FLOORS E60 F MASONRY F10 BRICK/ BLOCK WALLING F F10/110 CLAY FACING BRICKWORK F10 F10/170 CALCIUM SILICATE FACING BRICKWORK F10 F10/215 CONCRETE FACING BRICKWORK F10 F10/230 RECLAIMED BRICK FACING BRICKWORK F10 F10/255 CONCRETE FACING BLOCKWORK F10 F10/290 MANUFACTURED STONE BLOCKWORK F10 F10/295 MANUFACTURED STONE BLOCKWORK F10 F10/315 CLAY COMMON BRICKWORK F10 F10/325 THIN JOINT CLAY COMMON BLOCKWORK F10 F10/335 CALCIUM SILICATE COMMON BRICKWORK F10 F10/345 CONCRETE COMMON BRICKWORK F10 F10/355 CONCRETE COMMON BLOCKWORK F10 F10/360 AUTOCLAVED AERATED CONCRETE (AAC) COMMON BLOCKWORK F10 F10/370 THIN JOINT AUTOCLAVED AERATED CONCRETE (AAC) COMMON BLOCKWORK F10 F10/375 GYPSUM BLOCKWORK F10 F10/385 ENGINEERING BRICKWORK F10 F10/395 DAMP PROOF COURSE BRICKWORK F10 F10/400 HARD LANDSCAPING MATERIALS SPECIFICATION F10 F10/410 COMPRESSIVE STRENGTH OF MORTAR FOR EACH WALLING TYPE F10 F10/415 FRESH MORTAR CEMENT CONTENT F10 F10/430 CONDITIONING OF CLAY AND CALCIUM SILICATE BRICKS AND CLAY BLOCKS F10 F10/440 CONDITIONING OF CONCRETE BRICKS/ BLOCKS F10 F10/460 MORTAR GROUPS F10 F10/500 LAYING GENERALLY F10 F10/520 ACCURACY F10 F10/535 HEIGHT OF LIFTS IN WALLING USING CEMENT GAUGED OR HYDRAULIC LIME MORTAR F10 F10/540 HEIGHT OF LIFTS IN WALLING USING THIN JOINT MORTAR GLUE F10 F10/545 LEVELLING OF SEPARATE LEAVES F10 F10/560 COURSING BRICKWORK F10 F10/561 COURSING BRICKWORK WITH EXISTING F10 F10/580 LAYING FROGGED BRICKS F10 F10/585 LAYING CELLULAR BRICKS F10 F10/587 LAYING GYPSUM BLOCKS WITH TONGUES AND GROOVES F10 F10/595 LINTELS F10 F10/610 SUPPORT OF EXISTING WORK F10 F10/615 BRICKWORK TO RECEIVE ASPHALT DPC F10 F10/620 BLOCK BONDING NEW WALLS TO EXISTING F10 F10/635 JOINTING F10 F10/645 ACCESSIBLE JOINTS NOT EXPOSED TO VIEW F10 F10/665 POINTING F10 F10/671 FIRE STOPPING F10 F10/690 ADVERSE WEATHER F10 F10/710 THE TERM FACEWORK F10 F10/730 BRICK/ CONCRETE BLOCK SAMPLES F10 F10/740 FINISHED MASONRY WORK REFERENCE PANELS F10 F10/745 MASONRY SAMPLE PANELS F10 F10/750 COLOUR CONSISTENCY OF MASONRY UNITS F10 F10/760 APPEARANCE F10 F10/770 TEXTURED BRICKS F10 F10/780 GROUND LEVEL F10 F10/790 PUTLOG SCAFFOLDING F10 F10/800 TOOTHED BOND F10 F10/810 FIXING OF BRICK SLIPS F10 F10/830 CLEANLINESS F10 F11 GLASS BLOCK WALLING F F11/111 MORTAR JOINTED GLASS BLOCK WALLING F11 F11/116 MORTAR JOINTED, SEALANT POINTED GLASS BLOCK WALLING F11 F11/121 SEALANT JOINTED GLASS BLOCK WALLING F11 F11/131 MORTAR JOINTED GLASS BLOCK WALLING F11 F11/136 MORTAR JOINTED, SEALANT POINTED GLASS BLOCK WALLING F11 F11/141 SEALANT JOINTED GLASS BLOCK WALLING F11 F11/205 CONTRACTOR'S DESIGN F11 F11/208 COMPLETION OF DESIGN F11 F11/211 STRUCTURAL DESIGN PROVIDED F11 F11/215 GLASS BLOCK SAMPLES F11 F11/216 ACCESSORIES SAMPLES F11 F11/217 FINISHED WORK REFERENCE PANELS F11 F11/220 WEATHERTIGHTNESS F11 F11/221 WEATHERTIGHTNESS F11 F11/350 SUITABILITY OF SURROUNDS F11 F11/360 PREPARATION OF SURROUNDS F11 F11/370 ADVERSE WEATHER F11 F11/375 ADVERSE WEATHER F11 F11/380 LAYING GLASS BLOCKS WITH MORTAR JOINTS F11 F11/385 LAYING GLASS BLOCKS WITH SEALANT JOINTS F11 F11/390 JOINT REINFORCEMENT F11 F11/400 RESTRAINT/ ANCHOR FIXINGS F11 F11/410 PERIMETER/ EXPANSION JOINTS WITH SEALANT F11 F11/420 SPACERS F11 F11/430 MORTAR JOINTING F11 F11/435 MORTAR POINTING F11 F11/437 SEALANT POINTING F11 F20 NATURAL STONE RUBBLE WALLING F F20/102 CONTRACTOR'S DESIGN F20 F20/104 STRUCTURAL DESIGN PROVIDED F20 F20/110 RUBBLE WALLING F20 F20/120 HARD LANDSCAPING MATERIALS SPECIFICATION F20 F20/240 STONE SAMPLES F20 F20/250 SAND SAMPLES F20 F20/300 REFERENCE PANELS F20 F20/315 ADVERSE WEATHER F20 F20/325 LAYING GENERALLY F20 F20/330 WALLING BELOW GROUND LEVEL F20 F20/340 PUTLOG SCAFFOLDING F20 F20/350 CAVITY WALLS F20 F20/360 QUOINS AND JAMBS IN RUBBLE WALLING F20 F20/370 BONDERS FOR WALLS FACED BOTH SIDES F20 F20/380 COURSED WORK F20 F20/390 BRUSHED FINISH TO JOINTS F20 F20/410 SUPPORT OF EXISTING WORKS F20 F21 NATURAL STONE/ ASHLAR WALLING/ DRESSINGS F F21/110 ASHLAR F21 F21/120 HARD LANDSCAPING MATERIALS SPECIFICATION F21 F21/240 STONE SAMPLES F21 F21/250 CUTTING AND DRESSING OF STONE F21 F21/260 IDENTIFICATION OF STONE UNITS F21 F21/270 INSPECTION OF STONE UNITS F21 F21/280 SAND SAMPLES F21 F21/300 REFERENCE PANELS F21 F21/315 ADVERSE WEATHER F21 F21/325 LAYING GENERALLY F21 F21/330 WALLING BELOW GROUND LEVEL F21 F21/340 PUTLOG SCAFFOLDING F21 F21/350 ONE PIECE SILLS/ THRESHOLDS F21 F21/360 OPENINGS F21 F21/370 JOGGLE JOINTS F21 F21/390 POINTING F21 F21/410 SUPPORT OF EXISTING WORK F21 F22 CAST STONE ASHLAR WALLING/DRESSINGS F F22/102 CONTRACTOR'S DESIGN F22 F22/104 STRUCTURAL DESIGN PROVIDED F22 F22/110 CAST STONE F22 F22/120 HARD LANDSCAPING MATERIALS SPECIFICATION F22 F22/220 CONTROL SAMPLES F22 F22/230 QUALITY ASSURANCE F22 F22/255 COMPRESSIVE STRENGTH F22 F22/300 REINFORCEMENT F22 F22/305 BED JOINT REINFORCEMENT F22 F22/312 COVER TO REINFORCEMENT F22 F22/335 MANUFACTURING ACCURACY F22 F22/340 MIXES GENERALLY F22 F22/350 SEPARATE FACING AND BACKING MIXES F22 F22/360 CASTING AND CURING F22 F22/370 QUALITY OF FINISHES F22 F22/380 INSPECTION F22 F22/400 SAND SAMPLES F22 F22/410 REFERENCE PANELS F22 F22/430 ADVERSE WEATHER F22 F22/440 LAYING GENERALLY F22 F22/450 WALLING/ DRESSINGS BELOW GROUND LEVEL F22 F22/490 PUTLOG SCAFFOLDING F22 F22/500 ONE PIECE SILLS/ THRESHOLDS F22 F22/510 OPENINGS F22 F22/520 JOGGLE JOINTS F22 F22/535 POINTING F22 F22/540 SUPPORT OF EXISTING WORK F22 F30 ACCESSORIES/ SUNDRY ITEMS FOR BRICK/ BLOCK/ STONE WALLING F F30/10 FULL FILL CAVITY INSULATION F30 F30/110 CONCRETE FILL TO BASE OF CAVITY F30 F30/12 PARTIAL FILL CAVITY INSULATION F30 F30/120 CLEANLINESS F30 F30/130 PERPEND JOINT WEEP HOLES F30 F30/131 BED JOINT WEEP HOLES F30 F30/132 PERPEND JOINT PLASTICS WEEP HOLES F30 F30/15 AIR BRICKS IN EXTERNAL WALLING F30 F30/150 FULL FILL CAVITY INSULATION F30 F30/155 PARTIAL FILL CAVITY INSULATION F30 F30/16 GRATINGS/ VENTILATORS IN INTERNAL WALLING F30 F30/160 AIR BRICKS IN EXTERNAL WALLING F30 F30/165 GRATINGS/ VENTILATORS IN INTERNAL WALLING F30 F30/17 VENTILATION DUCTS IN EXTERNAL WALLING F30 F30/171 VENTILATION DUCTS IN EXTERNAL WALLING F30 F30/175 CAVITY VENTILATORS F30 F30/18 CAVITY CLOSERS F30 F30/180 CAVITY CLOSERS F30 F30/185 TRANSMITTED NOISE REDUCTION SYSTEM F30 F30/20 CAVITY WALL TIES F30 F30/21 CAVITY WALL TIES USED WITH PARTIAL INSULATION F30 F30/210 CAVITY WALL TIES F30 F30/211 CAVITY WALL TIES USED WITH PARTIAL FILL INSULATION F30 F30/214 CAVITY WALL TIES F30 F30/215 CAVITY WALL TIES USED WITH PARTIAL FILL INSULATION F30 F30/216 SHEAR WALL TIES F30 F30/218 SHEAR WALL TIES F30 F30/220 WALL TIES F30 F30/224 INDIVIDUAL BRACKETS F30 F30/225 FIXING TIES IN MASONRY CAVITY WALLS F30 F30/228 FIXING TIES IN MASONRY CAVITY WALLS WITH FULL FILL CAVITY INSULATION F30 F30/233 FIXING TIES IN MASONRY CAVITY WALLS WITH PARTIAL FILL CAVITY INSULATION F30 F30/236 FIXING TIES IN MASONRY CLADDING TO TIMBER FRAMES F30 F30/24 CAVITY WALL TIES F30 F30/241 WALL STARTERS/ CONNECTORS F30 F30/242 SURFACE MOUNTED CHANNELS/ SLOTS F30 F30/245 CHANNEL/ SLOT TIES F30 F30/248 CHANNEL/ SLOT TIES USED WITH PARTIAL FILL INSULATION F30 F30/25 CAVITY WALL TIES USED WITH PARTIAL FILL INSULATION F30 F30/250 SLIDING ANCHOR RESTRAINT SLIP TIES F30 F30/251 WALL HEAD RESTRAINT SLIP TIES F30 F30/255 WIND POSTS F30 F30/26 WALL TIES F30 F30/260 ANGLE SUPPORTS F30 F30/265 SUPPORT SYSTEM F30 F30/270 MESHWORK JOINT REINFORCEMENT F30 F30/28 FIXING TIES IN MASONRY CAVITY WALLS F30 F30/280 LATERAL RESTRAINT NONPROPRIETARY SLIP TIES FOR MOVEMENT JOINTS F30 F30/281 LATERAL RESTRAINT PROPRIETARY SLIP TIES FOR MOVEMENT JOINTS F30 F30/282 GENERAL PURPOSE SLIP TIES FOR MOVEMENT JOINTS F30 F30/290 PROPRIETARY SPECIAL FIXINGS F30 F30/291 SPECIAL FIXINGS F30 F30/310 DAMP PROOF COURSE - BITUMEN BASED F30 F30/320 DAMP PROOF COURSE - POLYETHYLENE F30 F30/33 FIXING TIES IN MASONRY CAVITY WALLS WITH PARTIAL FILL CAVITY INSULATION F30 F30/330 DAMP PROOF COURSE - F30 F30/340 SITE FORMED FLEXIBLE SHEET CAVITY TRAYS - BITUMEN BASED F30 F30/345 SITE FORMED FLEXIBLE SHEET CAVITY TRAYS F30 F30/360 GAS RESISTANT DPCS/ CAVITY TRAYS F30 F30/37 FIXING TIES IN MASONRY CLADDING TO TIMBER FRAMES F30 F30/370 PREFORMED CAVITY TRAYS F30 F30/380 PREFORMED DPC/ CAVITY TRAY JUNCTION CLOAKS/ STOP ENDS F30 F30/385 PREFORMED DPC/ CAVITY TRAY JUNCTION CLOAKS/ STOP ENDS F30 F30/39 WALL STARTERS/ CONNECTORS F30 F30/390 SITE FORMED DPC/ CAVITY TRAY JUNCTIONS/ STOP ENDS F30 F30/40 SURFACE MOUNTED CHANNELS/ SLOTS F30 F30/415 HORIZONTAL DPCS F30 F30/42 MESHWORK JOINT REINFORCEMENT F30 F30/425 GROUND LEVEL DPCS F30 F30/435 STEPPED DPCS IN EXTERNAL WALLS F30 F30/44 DAMP PROOF COURSE - BITUMEN BASED F30 F30/445 SILL DPCS F30 F30/455 COPING/ CAPPING DPCS F30 F30/46 DAMP PROOF COURSE - POLYETHYLENE F30 F30/465 SEALING DPCS F30 F30/475 SITE FORMED CAVITY TRAYS F30 F30/48 DAMP PROOF COURSE F30 F30/485 CAVITY TRAYS OVER OPENINGS AND OTHER CAVITY BRIDGINGS F30 F30/495 GAS RESISTANT DPCS/ CAVITY TRAYS F30 F30/5 CAVITIES F30 F30/515 DPC/ CAVITY TRAY LEADING EDGE IN FACEWORK - FLUSH F30 F30/52 SITE FORMED FLEXIBLE SHEET CAVITY TRAYS F30 F30/525 DPC/ CAVITY TRAY LEADING EDGE IN FACEWORK - SET BACK F30 F30/535 DPC/ CAVITY TRAY LEADING EDGE IN FACEWORK - PROJECTING F30 F30/54 GAS RESISTANT DPCS/ CAVITY TRAYS F30 F30/56 PREFORMED CAVITY TRAYS F30 F30/560 VERTICAL DPCS GENERALLY F30 F30/570 JAMB DPCS AT OPENINGS F30 F30/58 PREFORMED DPC/ CAVITY TRAY JUNCTION CLOAKS/ STOP ENDS F30 F30/580 JAMB DPCS TO BUILT IN TIMBER FRAMES F30 F30/610 MOVEMENT JOINTS WITH SEALANT F30 F30/615 MOVEMENT JOINTS WITHOUT SEALANT F30 F30/616 FIRE RESISTANT MOVEMENT JOINTS WITHOUT SEALANT F30 F30/62 SITE FORMED DPC/ CAVITY TRAY JUNCTIONS/ STOP ENDS F30 F30/630 UNEXPOSED CONTRACTION JOINTS F30 F30/650 POINTING IN FLASHINGS F30 F30/655 POINTING IN ASPHALT SKIRTINGS F30 F30/66 INSTALLATION OF HORIZONTAL DPCS F30 F30/660 PINNING UP TO SOFFITS F30 F30/670 TOPS OF NONLOADBEARING WALLS F30 F30/68 SEALING DPCS F30 F30/7 PERPEND JOINT WEEP HOLES F30 F30/72 INSTALLATION OF GAS RESISTANT DPCS/ CAVITY TRAYS F30 F30/720 SILLS F30 F30/721 NATURAL STONE SILLS LAID IN HYDRAULIC LIME:SAND MORTAR F30 F30/725 CAST STONE SILLS LAID IN CEMENT GAUGED MORTAR F30 F30/726 CAST STONE SILLS LAID IN HYDRAULIC LIME:SAND MORTAR F30 F30/735 PRECAST CONCRETE LINTELS F30 F30/74 INSTALLATION OF VERTICAL DPCS F30 F30/745 PRESTRESSED CONCRETE LINTELS F30 F30/755 PREFABRICATED STEEL LINTELS F30 F30/76 MOVEMENT JOINTS WITH SEALANT F30 F30/760 COPING UNITS F30 F30/761 NATURAL STONE COPING UNITS LAID IN HYDRAULIC LIME:SAND MORTAR F30 F30/765 CAST STONE COPING UNITS LAID IN CEMENT GAUGED MORTAR F30 F30/766 CAST STONE COPING UNITS LAID IN HYDRAULIC LIME:SAND MORTAR F30 F30/770 CAST STONE DRESSINGS LAID IN CEMENT GAUGED MORTAR F30 F30/771 CAST STONE DRESSINGS LAID IN HYDRAULIC LIME:SAND MORTAR F30 F30/78 MOVEMENT JOINTS WITHOUT SEALANT F30 F30/780 COPING SYSTEM F30 F30/8 PERPEND JOINT PLASTICS WEEP HOLES F30 F30/810 TILE SILLS F30 F30/820 TILE CREASING F30 F30/83 PRECAST CONCRETE LINTELS F30 F30/830 BUILDING IN FRAMES F30 F30/840 OPENINGS FOR FRAMES F30 F30/85 PREFABRICATED STEEL LINTELS F30 F30/850 WALL PLATES F30 F30/86 TILE SILLS F30 F30/88 CLAY/ CERAMIC FLUE LINING SYSTEM F30 F30/89 CONCRETE FLUE LINING SYSTEM F30 F30/910 CLAY/ CERAMIC FLUE LINING SYSTEM F30 F30/915 CONCRETE FLUE LINING SYSTEM F30 F30/92 CONCRETE FLUE BLOCK SYSTEM F30 F30/920 CONCRETE FLUE BLOCK SYSTEM F30 F30/923 CONCRETE FLUE BLOCK SYSTEM F30 F30/925 CLAY/ CERAMIC FLUE BLOCK SYSTEM F30 F30/93 CONCRETE FLUE BLOCK SYSTEM F30 F30/930 FIREPLACE COMPONENTS F30 F30/94 FIREPLACE COMPONENTS F30 F30/940 CHIMNEY POTS F30 F30/96 CHIMNEY POTS F30 F30/970 REFUSE CHUTES AND ACCESSORIES F30 F31 PRECAST CONCRETE SILLS/ LINTELS/ COPINGS/ FEATURES F F31/10 CONCEALED PRECAST LINTELS F31 F31/105 PRECAST F31 F31/112 DESIGNATED CONCRETE PRECAST F31 F31/122 DESIGNED CONCRETE PRECAST F31 F31/125 SUBSTITUTION OF PROPRIETARY CONCRETE FOR DESIGNATED CONCRETE F31 F31/130 CONCEALED PRECAST LINTELS F31 F31/140 CONCEALED PRECAST LINTELS F31 F31/150 CONCEALED PRECAST F31 F31/20 MOULDS F31 F31/210 MOULDS F31 F31/220 CONCRETE GENERALLY F31 F31/25 REINFORCEMENT F31 F31/250 REINFORCEMENT F31 F31/255 QUALITY ASSURANCE OF REINFORCEMENT F31 F31/260 CASTING AND CURING F31 F31/261 CUTTING F31 F31/262 RECORDS F31 F31/30 CASTING AND CURING F31 F31/310 CONTROL SAMPLES F31 F31/32 CUTTING F31 F31/320 DETAILS OF SAMPLES F31 F31/330 MIXES FOR VISIBLE FACED COMPONENTS F31 F31/341 CONDITIONS FOR SEPARATE FACING AND BACKING MIXES F31 F31/35 CONDITIONS FOR SEPARATE FACING AND BACKING MIXES F31 F31/350 QUALITY OF FINISHES F31 F31/365 COVER ON EXPOSED AGGREGATE FACES F31 F31/370 COVER ON VISIBLE FACES F31 F31/380 CONSISTENCY OF PRODUCTION METHODS F31 F31/390 INSPECTION F31 F31/40 LAYING F31 F31/420 LAYING F31 F31/430 SUPPORT OF EXISTING WORK OVER NEW LINTELS F31 F31/440 ONE PIECE SILLS/ THRESHOLDS F31 F31/45 SUPPORT OF EXISTING WORK OVER NEW LINTELS F31 F31/5 DESIGNATED CONCRETE PRECAST F31 F31/7 SUBSTITUTION OF PROPRIETARY CONCRETE FOR DESIGNATED CONCRETE F31 F42 STRAW BALE WALLING SYSTEMS F F42/110 UNFRAMED STRAW BALE WALLING SYSTEM F42 F42/120 FRAMED STRAW BALE WALLING SYSTEM F42 F42/205 CONTRACTOR'S DESIGN F42 F42/208 COMPLETION OF DESIGN F42 F42/211 STRUCTURAL DESIGN PROVIDED F42 F42/230 FIRE PERFORMANCE F42 F42/240 WEATHERTIGHTNESS F42 F42/250 DURABILITY F42 F42/260 THERMAL PERFORMANCE F42 F42/305 DAMP-PROOF COURSES F42 F42/307 FLOOR PLATES F42 F42/310 STRAW BALES F42 F42/312 PREFABRICATED PANELS F42 F42/315 STRAW F42 F42/320 POLYPROPYLENE BALING TWINE F42 F42/325 STAINLESS STEEL WIRE F42 F42/330 HAZEL PINS F42 F42/335 STRAPPING F42 F42/340 LINTELS F42 F42/345 LINTEL INSULATION F42 F42/350 HOLDING-DOWN BOLTS F42 F42/360 ORIENTED STRAND BOARD F42 F42/365 PLYWOOD F42 F42/370 SOFTWOOD F42 F42/380 ADHESIVES F42 F42/385 NAILS F42 F42/390 SCREWS F42 F42/395 NAILING BLOCKS F42 F42/400 FLASHINGS AND WEATHERINGS F42 F42/410 EARTH F42 F42/415 LIME F42 F42/420 SAND F42 F42/425 WATER REPELLENT ADDITIVE F42 F42/430 METAL LATH AND MESH F42 F42/435 STAPLES AND HOOPS F42 F42/510 STRAW BALES, BESPOKE F42 F42/610 TEMPORARY WORK F42 F42/615 INSTALLING DAMP-PROOF COURSES F42 F42/620 BUILDING IN F42 F42/625 LAYING BALES F42 F42/630 WALL CONSTRUCTION TOLERANCES F42 F42/635 LINTELS SUPPORTING BALE COURSES F42 F42/640 INSTALLING HOLDING-DOWN BOLTS F42 F42/650 WALL PLATES F42 F42/655 INSTALLING WALL PLATES F42 F42/660 DOOR AND WINDOW CASINGS F42 F42/670 DOOR AND WINDOW FRAME REVEALS F42 F42/680 APPLYING ADHESIVES F42 F42/690 INSTALLING CASINGS AND FRAME REVEALS F42 F42/700 INSTALLING FLASHINGS AND WEATHERINGS F42 F42/710 EARTH PLASTER AND RENDER F42 F42/715 EARTH PLASTERING AND RENDERING F42 F42/810 SUBMITTALS F42 F42/820 TEMPORARY WORK F42 F42/830 SPARES F42 G STRUCTURAL/CARCASSING METAL/TIMBER G10 STRUCTURAL STEEL FRAMING G G10/110 CONTRACTOR'S DESIGN OF JOINTS G10 G10/111 CONTRACTOR'S DESIGN OF MEMBERS AND JOINTS G10 G10/112 CONTRACTOR'S DESIGN G10 G10/115 DESIGN CONSTRAINTS - GENERAL G10 G10/116 DESIGN CONSTRAINTS - STEELWORK TO BE GALVANIZED G10 G10/120 DRAWINGS AND CALCULATIONS G10 G10/123 DRAWINGS AND CALCULATIONS PREPARED BY CONTRACTOR G10 G10/125 SPECIFICATION STANDARD G10 G10/130 GENERAL STEEL SECTIONS AND PLATES G10 G10/135 HOLLOW STEEL SECTIONS G10 G10/150 STEEL FRAMING SYSTEM G10 G10/155 FLAT TO PITCH ROOF FRAMING SYSTEM G10 G10/160 SPACE GRID SYSTEM G10 G10/170 COLD-FORMED GALVANIZED STEEL G10 G10/176 PROFILED SHEET FOR SHUTTERING/ COMPOSITE FLOOR SLABS G10 G10/178 FIXING PROFILED SHEET TO STEELWORK G10 G10/180 NOTIFICATION OF COMMENCEMENT G10 G10/190 MARKING G10 G10/195 HARD STAMPING G10 G10/200 FAYING SURFACES FOR FRICTION GRIP CONNECTIONS G10 G10/210 END CONNECTIONS G10 G10/215 HOLLOW SECTIONS G10 G10/220 ACCESS/ VENTILATION HOLES IN BASE PLATES G10 G10/225 STEELWORK TO BE GALVANIZED G10 G10/235 SHOP INSPECTION G10 G10/240 TRIAL SHOP ASSEMBLY G10 G10/250 SPECIAL WELDING PROCEDURES G10 G10/255 SITE WELDING G10 G10/270 ADDITIONAL WELDS G10 G10/280 SHEAR CONNECTORS G10 G10/285 PROPRIETARY SHEAR CONNECTORS G10 G10/302 NON-PRELOADED BOLT ASSEMBLIES G10 G10/303 PRELOADED BOLT ASSEMBLIES G10 G10/304 PROPRIETARY BOLT ASSEMBLIES G10 G10/305 PROPRIETARY ANCHORS G10 G10/310 ANCHORAGES TO CONCRETE G10 G10/325 DIRECT TENSION INDICATORS G10 G10/335 SPRING WASHERS G10 G10/370 GALVANIZED COATING TO BOLT ASSEMBLIES G10 G10/375 SHERARDIZED COATING TO BOLT ASSEMBLIES G10 G10/380 ZINC PLATED FINISH TO BOLT ASSEMBLIES G10 G10/390 SEALED HOLLOW SECTIONS G10 G10/405 OUTLINE METHOD OF ERECTION G10 G10/410 PRE-ERECTION CHECKS G10 G10/420 SETTING OUT G10 G10/425 MODIFICATIONS G10 G10/432 TEMPORARY SUPPORT G10 G10/440 COLUMN BASES G10 G10/441 MORTAR FILLING/ BEDDING OF COLUMN BASES G10 G10/442 FINE CONCRETE FILLING/ BEDDING OF COLUMN BASES G10 G10/443 PROPRIETARY FILLING/ BEDDING OF COLUMN BASES G10 G10/445 MOVEMENT JOINTS G10 G10/447 BONDED ANCHORS G10 G10/465 TESTING G10 G10/467 EXCEPTIONS TO NSSS REQUIREMENTS FOR WELD TESTING G10 G10/470 SITE TESTING OF ANCHORS TO MASONRY G10 G10/475 PRODUCTS G10 G10/510 SURFACES NOT TO BE COATED G10 G10/521 ALTERNATIVE MANUFACTURERS G10 G10/523 COMPATIBILITY OF SHOP PRIMER WITH SITE APPLIED INTUMESCENT COATING G10 G10/535 INSPECTION OF COATING WORK G10 G10/550 POST-GALVANIZING INSPECTION G10 G10/610 GALVANIZING TO CHEMICALLY CLEANED STEEL G10 G10/620 GALVANIZING TO BLAST CLEANED STEEL G10 G10/630 GALVANIZING PLUS SITE APPLIED G10 G10/633 THERMALLY SPRAYED ZINC COATING G10 G10/635 THERMALLY SPRAYED ZINC COATING PLUS SITE APPLIED G10 G10/638 SHOP PRIMING FOR G10 G10/640 SHOP PAINTING WITH G10 G10/643 PROTECTIVE PAINTING G10 G10/650 SITE PAINTING WITH G10 G10/660 SHOP PLUS SITE PAINTING WITH G10 G10/710 OFFSITE PREPARATION AND PAINTING G10 G10/725 MANUAL CLEANING OF NEW STEELWORK G10 G10/730 PREPARATION FOR SITE WELDING OF SHOP PAINTED STEELWORK G10 G10/735 TREATMENT OF SITE WELDED JOINTS IN PAINTED STEELWORK G10 G10/736 TREATMENT OF SITE WELDED JOINTS IN GALVANIZED STEELWORK G10 G10/740 BOLTED JOINTS (OTHER THAN FRICTION GRIP JOINTS) G10 G10/745 FAYING SURFACES OF FRICTION GRIP JOINTS G10 G10/750 FRICTION GRIP JOINTS IN SHOP PAINTED STEELWORK G10 G10/755 UNCOATED FASTENERS G10 G10/760 GALVANIZED FASTENERS G10 G10/765 SITE PREPARATION OF SHOP PAINTED STEELWORK G10 G10/770 SITE PREPARATION OF GALVANIZED SURFACES FOR PAINTING G10 G10/810 ENVIRONMENTAL CONDITIONS G10 G10/815 COATINGS G10 G10/820 FILM THICKNESS G10 G10/825 STRIPE COAT G10 G10/850 JUNCTIONS WITH CONCRETE G10 G12 ISOLATED STRUCTURAL METAL MEMBERS G G12/320 STEEL G12 G12/330 PROPRIETARY G12 G12/340 BOLT ASSEMBLIES G12 G12/350 PROPRIETARY ANCHORS G12 G12/510 FABRICATION OF STEEL MEMBERS G12 G12/610 INSTALLATION G12 G12/620 BONDED ANCHORS G12 G12/630 SITE TESTING OF ANCHORS TO MASONRY G12 G12/640 PREPARATION AND PRIMING G12 G12/650 SHOP PRIMING G12 G12/910 STEEL TO TIMBER JOINTS G12 G20 CARPENTRY/ TIMBER FRAMING/ FIRST FIXING G G20/105 TIMBER PROCUREMENT G20 G20/115 CONTRACTOR'S STRUCTURAL DESIGN G20 G20/120 STRUCTURAL DESIGN PROVIDED G20 G20/150 STRENGTH GRADING OF TIMBER G20 G20/160 GRADING AND MARKING OF SOFTWOOD G20 G20/210 STRUCTURAL SOFTWOOD (GRADED DIRECT TO STRENGTH CLASS) G20 G20/230 STRUCTURAL SOFTWOOD (STRENGTH CLASS NOT SPECIFIED) G20 G20/250 STRUCTURAL HARDWOOD (GRADED DIRECT TO STRENGTH CLASS) G20 G20/260 STRUCTURAL HARDWOOD (STRENGTH CLASS NOT SPECIFIED) G20 G20/270 UNGRADED SOFTWOOD G20 G20/275 WOOD TRIM G20 G20/310 STRUCTURAL PLYWOOD G20 G20/311 NON-STRUCTURAL PLYWOOD G20 G20/320 TEMPERED HARDBOARD G20 G20/330 GLUED LAMINATED TIMBER G20 G20/331 PROPRIETARY GLUED LAMINATED TIMBER G20 G20/334 CROSS-LAMINATED TIMBER PANELS G20 G20/336 STRUCTURAL WOOD COMPOSITE G20 G20/341 PREFABRICATED STRUCTURAL WOOD COMPOSITE G20 G20/345 PROPRIETARY STRUCTURAL WOOD COMPOSITE G20 G20/347 STRUCTURAL INSULATED ROOF PANELS G20 G20/348 STRUCTURAL INSULATED WALL PANELS G20 G20/350 TRUSSED RAFTERS G20 G20/401 CROSS SECTION DIMENSIONS OF STRUCTURAL SOFTWOOD AND HARDWOOD G20 G20/402 CROSS SECTION DIMENSIONS OF NONSTRUCTURAL SOFTWOOD G20 G20/403 CROSS SECTION DIMENSIONS OF NONSTRUCTURAL HARDWOOD G20 G20/420 WARPING OF TIMBER G20 G20/430 SELECTION AND USE OF TIMBER G20 G20/435 NOTCHES, HOLES AND JOINTS IN TIMBER G20 G20/440 PROCESSING TREATED TIMBER G20 G20/450 MOISTURE CONTENT G20 G20/451 MOISTURE CONTENT TESTING G20 G20/460 PROTOTYPES G20 G20/470 COMPONENT TESTING G20 G20/480 TRUSSED RAFTER TESTING G20 G20/510 PROTECTION G20 G20/520 EXPOSED END GRAIN G20 G20/530 PAINTED FINISHES G20 G20/540 CLEAR FINISHES G20 G20/550 EXPOSED TIMBER G20 G20/570 JOINTING/FIXING GENERALLY G20 G20/580 FRAMING ANCHORS G20 G20/590 METAL PLATE FASTENERS/GUSSETS G20 G20/600 BLACK BOLTS AND NUTS G20 G20/615 BOLT/ SCREW ASSEMBLIES G20 G20/630 BOLTED JOINTS G20 G20/640 BOLTED JOINTS WITH CONNECTORS G20 G20/650 GLUED JOINTS G20 G20/660 PURPOSE MADE G20 G20/670 ANTI-CORROSION FINISHES FOR FASTENERS G20 G20/710 PROPOSALS FOR ERECTING STRUCTURAL TIMBER G20 G20/715 BONDED ANCHORS G20 G20/721 EXPANSION ANCHORS G20 G20/725 HAMMER-IN FASTENERS G20 G20/730 DEFORMED RODS G20 G20/740 PRE-ERECTION CHECKING G20 G20/750 MODIFICATIONS/REPAIRS G20 G20/760 TEMPORARY BRACING G20 G20/770 ADDITIONAL SUPPORTS G20 G20/775 BEARINGS G20 G20/780 WALL PLATES G20 G20/784 JOISTS GENERALLY G20 G20/786 JOISTS ON HANGERS G20 G20/790 STANDARD JOIST HANGERS G20 G20/791 PROPRIETARY JOIST HANGERS G20 G20/795 TRIMMING OPENINGS G20 G20/800 TRUSSED RAFTER INSTALLATION G20 G20/805 TRUSS CLIPS G20 G20/810 PERMANENT BRACING OF TRUSSED RAFTERS G20 G20/820 VERTICAL RESTRAINT STRAPS G20 G20/830 LATERAL RESTRAINT STRAPS G20 G20/840 STRUTTING TO FLOOR JOISTS G20 G20/850 INSPECTION GENERALLY G20 G20/860 BOLTED JOINTS INSPECTION G20 G20/870 ANCHOR TESTING G20 G20/900 EAVES SOFFIT VENTILATORS G20 G20/910 EAVES SOFFIT VENTILATION G20 G20/950 FASCIAS/ BARGES/ SOFFITS G20 G30 METAL PROFILED SHEET DECKING G G30/110 METAL PROFILED SHEET DECKING G30 G30/150 STRUCTURAL DESIGN OF ROOF DECKING G30 G30/160 STRUCTURAL DESIGN OF FLOOR DECKING G30 G30/170 STRUCTURAL DESIGN OF DECKING G30 G30/180 DESIGN REQUIREMENTS FOR DECKING G30 G30/220 PAINTING STRUCTURE G30 G30/230 PREVENTION OF ELECTROLYTIC ACTION G30 G30/240 FIRE RESISTING PROFILE FILLERS G30 G30/260 FIXING DECKING GENERALLY G30 G30/280 ATTACHMENT OF DECKING G30 G30/285 ATTACHMENT OF DECKING AND ACCESSORIES G30 G30/290 COLD FORMED METAL ACCESSORIES G30 H CLADDING/COVERING H10 PATENT GLAZING H H10/115 PATENT GLAZING H10 H10/120 MATERIALS SPECIFICATION H10 H10/205 CONTRACTOR'S DESIGN H10 H10/210 COMPLETION OF DESIGN H10 H10/215 STRUCTURAL DESIGN PROVIDED H10 H10/221 PRODUCT SAMPLES H10 H10/231 FASTENER SAMPLES H10 H10/311 REQUIREMENTS GENERALLY H10 H10/321 VERIFICATION OF PERFORMANCE H10 H10/341 FIRE RESISTANCE H10 H10/351 SURFACE SPREAD OF FLAME H10 H10/361 WATER PENETRATION H10 H10/365 WATER PENETRATION OF ROOF PATENT GLAZING H10 H10/371 HEAT CONSERVATION H10 H10/381 CONDENSATION H10 H10/391 SOLAR AND LIGHT CONTROL H10 H10/401 THERMAL SAFETY H10 H10/411 ACOUSTIC PROPERTIES H10 H10/421 SECURITY H10 H10/431 SECURITY DESIGN H10 H10/450 PROJECT TESTING (LABORATORY) H10 H10/475 DAYLIGHT PERFORMANCE H10 H10/480 VIEW OUT H10 H10/485 POTENTIAL FOR NATURAL VENTILATION H10 H10/510 WORKMANSHIP GENERALLY H10 H10/520 GLASS H10 H10/530 HEAT SOAKING OF THERMALLY TOUGHENED GLASS H10 H10/540 INSULATING GLASS UNITS H10 H10/550 PLASTICS GLAZING H10 H10/560 INFILLING H10 H10/570 SUITABILITY OF STRUCTURE H10 H10/575 OPENABLE WINDOWS IN NATURALLY VENTILATED BUILDINGS H10 H10/580 PROTECTION AND FINAL CLEANING H10 H11 CURTAIN WALLING H H11/10 INFORMATION TO BE PROVIDED WITH TENDER H11 H11/110 CURTAIN WALLING H11 H11/130 SUN SCREENS H11 H11/135 DOORS H11 H11/140 LOUVRES H11 H11/145 INTEGRATED ACCESS EQUIPMENT H11 H11/150 MATERIALS SPECIFICATION H11 H11/210 DESIGN H11 H11/215 DESIGN PROPOSALS H11 H11/220 SPECIFICATION H11 H11/230 INFORMATION TO BE PROVIDED DURING DETAILED DESIGN STAGE H11 H11/232 QUALITY PLAN H11 H11/235 INFORMATION TO BE PROVIDED BEFORE COMMENCEMENT TESTING OR FABRICATION OF CURTAIN WALLING H11 H11/240 INFORMATION TO BE PROVIDED BEFORE COMMENCEMENT OF STRUCTURAL SEALANT GLAZING H11 H11/250 PRODUCT SAMPLES H11 H11/260 SAMPLES OF FIXINGS H11 H11/270 FABRICATION SAMPLES H11 H11/280 MOCK-UP H11 H11/305 CWCT 'STANDARD FOR SYSTEMISED BUILDING ENVELOPES' H11 H11/311 INTEGRITY H11 H11/312 INTEGRITY H11 H11/313 INTEGRITY H11 H11/320 DEFLECTION UNDER DEAD LOADS H11 H11/325 DEFLECTION UNDER WIND LOAD H11 H11/330 GENERAL MOVEMENT H11 H11/332 APPEARANCE AND FIT H11 H11/335 THERMAL MOVEMENT - SERVICE TEMPERATURE RANGES H11 H11/340 AIR PERMEABILITY H11 H11/345 AIR PERMEABILITY EXFILTRATION H11 H11/350 WATER PENETRATION H11 H11/370 THERMAL PROPERTIES H11 H11/380 SOLAR AND LIGHT CONTROL H11 H11/385 THERMAL STRESS IN GLAZING H11 H11/390 AVOIDANCE OF CONDENSATION H11 H11/410 SOUND TRANSMITTANCE H11 H11/420 FIRE RESISTANCE OF CURTAIN WALLING H11 H11/425 INTERNAL SURFACE SPREAD OF FLAME OF CURTAIN WALLING H11 H11/430 FIRE STOPPING H11 H11/435 OPENING LIGHTS (WINDOWS) H11 H11/436 DOORS AND OTHER ACCESS FACILITIES H11 H11/437 LOUVRES H11 H11/440 DURABILITY H11 H11/445 LIGHTNING PROTECTION SYSTEM H11 H11/450 SAFETY H11 H11/460 STRUCTURAL SEALANT GLAZING REQUIREMENTS H11 H11/475 DAYLIGHT PERFORMANCE H11 H11/480 VIEW OUT H11 H11/485 POTENTIAL FOR NATURAL VENTILATION H11 H11/510 COMPARISON (TYPE) TESTING H11 H11/515 PROJECT TESTING (LABORATORY) H11 H11/520 PROJECT TESTING (SITE) H11 H11/530 TESTING AUTHORITY H11 H11/535 TESTING AUTHORITY H11 H11/540 TEST SPECIMEN H11 H11/550 TEST SEQUENCE - STANDARD LABORATORY TESTS H11 H11/555 TEST SEQUENCE - STANDARD LABORATORY TESTS H11 H11/560 TEST SEQUENCE - STANDARD LABORATORY AND DISCRETIONARY TESTS H11 H11/630 SITE SPRAY BAR TEST H11 H11/635 SITE HOSE TEST H11 H11/650 TEST H11 H11/655 WIND LOAD FATIGUE TEST, SMALL SPECIMEN H11 H11/660 STRUCTURAL SEALANT GLAZING TESTS H11 H11/710 ALUMINIUM ALLOY FRAMING SECTIONS H11 H11/712 ALUMINIUM ALLOY SHEET H11 H11/715 CARBON STEEL FRAMING SECTIONS/ REINFORCEMENT H11 H11/717 CARBON STEEL SHEET H11 H11/720 STAINLESS STEEL SHEET H11 H11/725 PVC-U FRAMING SECTIONS H11 H11/730 MECHANICAL FIXINGS H11 H11/732 ADHESIVES H11 H11/735 FIXING ANCHORS H11 H11/737 GLASS GENERALLY H11 H11/739 DIMENSIONAL TOLERANCES ON GLASS H11 H11/741 DISTORTIONAL TOLERANCES ON GLASS H11 H11/742 HEAT SOAKED THERMALLY TOUGHENED GLASS H11 H11/745 INSULATING GLASS UNITS H11 H11/747 GLASS EDGE CONDITION FOR STRUCTURAL SEALANT GLAZING H11 H11/750 INFILL PANELS/ FACINGS H11 H11/755 NATURAL STONE INFILL PANELS/ FACINGS H11 H11/760 GASKETS H11 H11/765 WEATHERSTRIPPING OF OPENING UNITS H11 H11/770 GENERAL SEALANTS H11 H11/772 CURTAIN WALLING JOINT ASSEMBLY SEALANTS H11 H11/775 BONDING SEALANTS FOR STRUCTURAL SEALANT GLAZING H11 H11/777 WEATHERSEALING FOR STRUCTURAL SEALANT GLAZING H11 H11/780 THERMAL INSULATION H11 H11/785 VAPOUR CONTROL LAYER H11 H11/810 PROTECTIVE COATING OF CARBON STEEL FRAMING SECTIONS/ REINFORCEMENT H11 H11/820 PROTECTIVE COATING OF CARBON STEEL MECHANICAL FIXINGS H11 H11/830 POWDER COATING H11 H11/840 ANODIZING H11 H11/850 POLYVINYLIDENE FLUORIDE (PVDF) COATING OF ALUMINIUM ALLOY H11 H11/910 GENERALLY H11 H11/912 METALWORK H11 H11/915 GLAZING H11 H11/917 FIXINGS/ ADHESIVES APPLICATION H11 H11/920 SEALANT APPLICATION H11 H11/925 STRUCTURAL SEALANT GLAZING H11 H11/930 ASSEMBLY H11 H11/935 OPENABLE WINDOWS IN NATURALLY VENTILATED BUILDINGS H11 H11/955 FIXING ANCHOR INSTALLATION H11 H11/965 PRELIMINARY CURTAIN WALLING INSTALLATION H11 H11/970 CURTAIN WALLING INSTALLATION H11 H11/975 WELDING H11 H11/980 INTERFACES H11 H11/982 IRONMONGERY H11 H11/985 MAINTENANCE H11 H13 STRUCTURAL GLASS ASSEMBLIES H H13/115 STRUCTURAL GLASS ASSEMBLY H13 H13/120 MATERIALS SPECIFICATION H13 H13/205 CONTRACTOR'S DESIGN H13 H13/210 COMPLETION OF DESIGN H13 H13/215 STRUCTURAL DESIGN PROVIDED H13 H13/225 INFORMATION TO BE PROVIDED BEFORE DETAILED DESIGN OF STRUCTURAL GLAZING H13 H13/231 INFORMATION TO BE PROVIDED BEFORE FABRICATION OF STRUCTURAL GLAZING H13 H13/241 LABELLED PRODUCT SAMPLES H13 H13/251 LABELLED SAMPLES OF FIXINGS H13 H13/261 MOCK-UP H13 H13/331 GENERAL MOVEMENT H13 H13/341 WEATHER RESISTANCE H13 H13/351 AIR PERMEABILITY H13 H13/355 WATER PENETRATION H13 H13/361 HEAT CONSERVATION H13 H13/371 VAPOUR CONTROL H13 H13/381 SOLAR AND LIGHT CONTROL H13 H13/391 THERMAL STRESS IN GLAZING H13 H13/401 SOUND TRANSMITTANCE H13 H13/411 ACCURACY OF ERECTION H13 H13/421 SECURITY H13 H13/430 ELECTRICAL CONDUCTIVITY AND EARTH BONDING H13 H13/440 DURABILITY H13 H13/475 DAYLIGHT PERFORMANCE H13 H13/480 VIEW OUT H13 H13/485 POTENTIAL FOR NATURAL VENTILATION H13 H13/510 PROJECT TESTING – LABORATORY H13 H13/520 PROJECT TESTING – SITE H13 H13/610 GLASS GENERALLY H13 H13/615 DIMENSIONAL TOLERANCES ON GLASS H13 H13/617 DISTORTIONAL TOLERANCES ON GLASS H13 H13/620 THERMALLY TOUGHENED GLASS H13 H13/630 LAMINATED GLASS H13 H13/640 SEALED INSULATING GLASS UNITS H13 H13/650 STAINLESS STEEL ASSEMBLY FIXINGS AND/ OR SUPPORTS H13 H13/660 ALUMINIUM ALLOY ASSEMBLY FIXINGS AND/ OR SUPPORTS H13 H13/670 BRASS ASSEMBLY FIXINGS H13 H13/710 WORKMANSHIP GENERALLY H13 H13/720 SUITABILITY OF SUPPORTING STRUCTURE H13 H13/730 STRUCTURAL GLAZING H13 H13/740 SEALANT JOINTS H13 H13/750 STRUCTURAL SEALANT JOINTS H13 H13/760 DOORS H13 H13/935 OPENABLE WINDOWS IN NATURALLY VENTILATED BUILDINGS H13 H14 PRECAST CONCRETE AND GLASS LENS/ PAVER ROOFLIGHTS/ FLOOR LIGHTS/ PAVEMENT LIGHTS/ SECURITY PANELS H H14/310 ROOFLIGHTS H14 H14/315 FLOORLIGHTS H14 H14/320 STAIR TREADS H14 H14/325 PAVEMENT LIGHTS H14 H14/330 NON GLAZED SMOKE OUTLET PANELS H14 H14/340 SECURITY WINDOW PANELS H14 H14/345 CONCRETE REINFORCEMENT H14 H14/350 MORTAR BEDDING H14 H14/355 MORTAR INFILL TO PERMANENTLY NON-ACCESSIBLE LIFTING SOCKETS H14 H14/360 PERIMETER MOVEMENT JOINTS H14 H14/365 INFORMATION H14 H14/370 SAMPLES H14 H14/601 SUITABILITY OF SURROUNDS/ SUPPORTS H14 H14/605 ADVERSE WEATHER H14 H14/610 INSTALLING PRECAST UNITS ON MORTAR BEDDING H14 H14/615 INSTALLING PERIMETER MOVEMENT JOINTS H14 H20 RIGID SHEET CLADDING H H20/150 SHEET CLADDING H20 H20/155 SHEET CLADDING H20 H20/210 CONTROL SAMPLES H20 H20/230 TIMBER BATTENS H20 H20/240 TREATED TIMBER H20 H20/260 FIXING SHEETS H20 H20/270 COVER STRIPS H20 H21 TIMBER WEATHERBOARDING H H21/110 VERTICAL TIMBER WEATHERBOARDING H21 H21/111 HORIZONTAL TIMBER WEATHERBOARDING H21 H21/115 VERTICAL TIMBER WEATHERBOARDING H21 H21/116 HORIZONTAL TIMBER WEATHERBOARDING H21 H21/120 CONTROL SAMPLE H21 H21/130 BREATHER MEMBRANE H21 H21/135 BATTENS/ COUNTERBATTENS H21 H21/140 FIXING BATTENS/ COUNTERBATTENS TO MASONRY H21 H21/141 FIXING BATTENS/ COUNTERBATTENS TO FRAMING/ SHEATHING H21 H21/142 FIXING BATTENS TO COUNTERBATTENS H21 H21/145 TREATED TIMBER H21 H21/150 SURFACE TREATMENT H21 H21/160 FIXING BOARDING H21 H30 FIBRE CEMENT PROFILED SHEET CLADDING/ COVERING H H30/110 FIBRE CEMENT H30 H30/120 FIBRE CEMENT H30 H30/150 GRP H30 H30/151 PVC-U H30 H30/155 POLYCARBONATE H30 H30/160 PLASTICS H30 H30/169 CONTRACTOR'S DESIGN H30 H30/171 COMPLETION OF DESIGN H30 H30/173 STRUCTURAL DESIGN PROVIDED H30 H30/175 PRODUCT SAMPLES H30 H30/178 FASTENER SAMPLES H30 H30/185 PERFORMANCE COMPLIANCE H30 H30/187 DEFLECTION OF FIBRE CEMENT CLADDING/ COVERING H30 H30/190 DEFLECTION OF PLASTICS CLADDING/ COVERING H30 H30/192 SOUND TRANSMITTANCE OF CLADDING/ COVERING SYSTEM - WEIGHTED H30 H30/193 SOUND TRANSMITTANCE OF CLADDING/ COVERING SYSTEM - FREQUENCY SPECIFIC H30 H30/194 INTERNAL SOUND ABSORPTION OF CLADDING/ COVERING SYSTEM H30 H30/198 WATER PENETRATION H30 H30/199 AVOIDANCE OF CONDENSATION H30 H30/215 PAINTING STRUCTURE H30 H30/219 FASTENERS H30 H30/221 FITTINGS AND ACCESSORIES H30 H30/223 FIBRE CEMENT FITTINGS H30 H30/234 GUTTERS H30 H30/240 FIBRE CEMENT LINING H30 H30/243 FOAMED PLASTICS LINING H30 H30/246 STEEL LINING H30 H30/247 STEEL LINING H30 H30/254 ACOUSTIC INSULATION H30 H30/261 VAPOUR CONTROL MEMBRANE H30 H30/310 MINERAL WOOL THERMAL INSULATION H30 H30/311 MINERAL WOOL THERMAL INSULATION H30 H30/350 BREATHER MEMBRANE H30 H30/360 PROFILE FILLERS GENERALLY H30 H30/370 FIRE RESISTING PROFILE FILLERS H30 H30/410 FIXING SHEETS GENERALLY H30 H30/415 FIXING FIBRE CEMENT SHEETS H30 H30/450 FIXING PLASTICS SHEETS H30 H30/453 METAL SHEETS H30 H30/457 PLASTICS DOUBLE SKIN CONSTRUCTION H30 H30/460 THERMAL MOVEMENT JOINTS H30 H30/470 STRUCTURAL MOVEMENT JOINTS H30 H30/530 FIBRE CEMENT GUTTERS H30 H30/540 ABUTMENTS H30 H30/550 SEALING LAPS ON EXTERNAL SHEETS H30 H30/554 WATER VAPOUR SEALING AT LAPS AND PENETRATIONS IN METAL LININGS H30 H30/555 WATER VAPOUR SEALING AT LAPS AND PENETRATIONS IN METAL LININGS H30 H30/560 WARNING NOTICES H30 H31 METAL PROFILED/ FLAT SHEET CLADDING/ COVERING H H31/110 METAL H31 H31/120 METAL H31 H31/150 GRP H31 H31/151 PVC-U H31 H31/155 POLYCARBONATE H31 H31/160 PLASTICS H31 H31/165 CONTRACTOR'S DESIGN H31 H31/167 COMPLETION OF DESIGN H31 H31/169 STRUCTURAL DESIGN PROVIDED H31 H31/172 THERMAL PERFORMANCE/ BRIDGING H31 H31/175 PRODUCT SAMPLES H31 H31/176 FASTENER SAMPLES H31 H31/185 PERFORMANCE COMPLIANCE H31 H31/187 DEFLECTION OF METAL CLADDING/ COVERING H31 H31/190 DEFLECTION OF PLASTICS CLADDING/ COVERING H31 H31/192 SOUND TRANSMITTANCE OF CLADDING/ COVERING SYSTEM - WEIGHTED H31 H31/193 SOUND TRANSMITTANCE OF CLADDING/ COVERING SYSTEM - FREQUENCY SPECIFIC H31 H31/194 INTERNAL SOUND ABSORPTION OF CLADDING/ COVERING SYSTEM H31 H31/198 WATER PENETRATION H31 H31/200 AVOIDANCE OF INTERSTITIAL CONDENSATION H31 H31/202 AVOIDANCE OF SURFACE CONDENSATION H31 H31/215 PAINTING STRUCTURE H31 H31/219 FASTENERS H31 H31/221 FITTINGS AND ACCESSORIES H31 H31/223 PREVENTION OF ELECTROLYTIC ACTION H31 H31/234 GUTTERS H31 H31/240 STEEL LINING H31 H31/241 STEEL LINING H31 H31/254 ACOUSTIC INSULATION H31 H31/261 VAPOUR CONTROL MEMBRANE H31 H31/270 MINERAL WOOL THERMAL INSULATION H31 H31/271 MINERAL WOOL THERMAL INSULATION H31 H31/280 BREATHER MEMBRANE H31 H31/300 PROFILE FILLERS GENERALLY H31 H31/305 FIRE RESISTING PROFILE FILLERS H31 H31/310 PURPOSE MADE COLD FORMED METAL ACCESSORIES H31 H31/410 FIXING SHEETS GENERALLY H31 H31/419 FIXING PLASTICS SHEETS H31 H31/435 PLASTICS MULTIPLE SKIN CONSTRUCTION H31 H31/460 ACCOMMODATION OF THERMAL MOVEMENT H31 H31/470 STRUCTURAL MOVEMENT JOINTS H31 H31/480 FLASHINGS/ TRIMS GENERALLY H31 H31/481 FLASHINGS/ TRIMS H31 H31/482 BUTT JOINTED FLASHINGS/ TRIMS H31 H31/540 ABUTMENTS H31 H31/550 SEALING LAPS ON EXTERNAL SHEETS H31 H31/554 WATER VAPOUR SEALING AT LAPS AND PENETRATIONS IN METAL LININGS - SEALANT TAPE H31 H31/555 WATER VAPOUR SEALING AT LAPS AND PENETRATIONS IN METAL LININGS - ALUMINIUM TAPE H31 H31/560 SAFETY SIGNS H31 H32 PLASTICS PROFILED SHEET CLADDING/ COVERING H H32/110 GRP H32 H32/111 PVC-U H32 H32/115 POLYCARBONATE H32 H32/120 PLASTICS H32 H32/151 CONTRACTOR'S DESIGN H32 H32/153 COMPLETION OF DESIGN H32 H32/155 STRUCTURAL DESIGN PROVIDED H32 H32/160 PRODUCT SAMPLES H32 H32/165 FASTENER SAMPLES H32 H32/175 PERFORMANCE COMPLIANCE H32 H32/180 DEFLECTION H32 H32/191 WATER PENETRATION H32 H32/210 PAINTING STRUCTURE H32 H32/213 FASTENERS H32 H32/217 ACCESSORIES H32 H32/220 PROFILE FILLERS H32 H32/230 FIXING SHEETS GENERALLY H32 H32/240 MULTIPLE SKIN CONSTRUCTION H32 H32/260 ACCOMMODATION OF THERMAL MOVEMENT H32 H32/320 ABUTMENTS H32 H32/330 SEALING LAPS H32 H32/340 WARNING NOTICES H32 H40 GLASS FIBRE REINFORCED CONCRETE CLADDING/ COMPONENTS H H40/110 GRC CLADDING H40 H40/120 GRC COMPONENTS H40 H40/130 PROPRIETARY GRC COMPONENTS H40 H40/205 CONTRACTOR'S DESIGN H40 H40/207 COMPLETION OF DESIGN H40 H40/209 STRUCTURAL DESIGN PROVIDED H40 H40/220 FIXINGS AND FASTENERS TO CLADDING H40 H40/225 FIXINGS AND FASTENERS TO COMPONENTS H40 H40/230 AIR BARRIER H40 H40/240 INFORMATION TO BE PROVIDED DURING DETAILED DESIGN H40 H40/250 PRODUCT CONTROL SAMPLES H40 H40/260 FIXING SAMPLES H40 H40/270 MOCK-UP H40 H40/330 PANEL ACCURACY H40 H40/410 QUALITY CONTROL H40 H40/420 DRY MATERIALS H40 H40/430 WET MATERIALS H40 H40/440 CURED MATERIALS H40 H40/450 PRODUCTION NON-COMPLIANCE H40 H40/510 ALKALI-RESISTANT GLASS FIBRE H40 H40/520 CEMENT H40 H40/530 SAND H40 H40/540 MIXING WATER H40 H40/550 ADMIXTURES H40 H40/560 PIGMENTS H40 H40/570 AGGREGATE FINISH H40 H40/575 VENEER H40 H40/580 SURFACE COATING H40 H40/610 GENERALLY H40 H40/615 MOULDS H40 H40/620 CEMENTITIOUS SLURRY H40 H40/625 PREMIX GRC H40 H40/630 SPRAY-UP GRC H40 H40/640 MIST COAT H40 H40/645 FACE MIX H40 H40/650 BACKING MIX H40 H40/660 CONSOLIDATION H40 H40/670 STUD FRAME H40 H40/680 CURING NON-POLYMER GRADE GRC H40 H40/685 CURING POLYMER GRADE GRC H40 H40/710 GENERALLY H40 H40/720 SUITABILITY OF STRUCTURE H40 H40/730 INSTALLATION OF INTERFACES H40 H40/740 METALWORK H40 H40/750 WELDING H40 H40/755 WELDING H40 H40/760 ACCURACY OF ERECTION OF CLADDING H40 H40/765 ACCURACY OF ERECTION OF GRC COMPONENTS H40 H40/770 FIXING H40 H40/780 SEALANT JOINTING H40 H40/785 SEALANT JOINTING H40 H41 GLASS FIBRE REINFORCED PLASTICS CLADDING/ FEATURES H H41/110 GRP SINGLE SKIN CLADDING H41 H41/120 GRP DOUBLE SKIN INSULATED PANEL CLADDING H41 H41/130 GRP PURPOSE MADE FEATURES H41 H41/140 GRP PROPRIETARY FEATURES H41 H41/205 CONTRACTOR'S DESIGN H41 H41/207 COMPLETION OF DESIGN H41 H41/209 STRUCTURAL DESIGN PROVIDED H41 H41/215 THERMAL PERFORMANCE/ BRIDGING H41 H41/220 WEATHER RESISTANCE H41 H41/240 HORIZONTAL DEFLECTION OF VERTICAL PANELS H41 H41/250 VERTICAL DEFLECTION OF HORIZONTAL PANELS H41 H41/260 FIRE RATING CERTIFICATION H41 H41/270 COLOUR FASTNESS/ APPEARANCE OF GRP H41 H41/275 COLOUR FASTNESS/ APPEARANCE SAMPLES H41 H41/285 COLOUR FASTNESS/ APPEARANCE OF EXISTING GRP H41 H41/320 DESIGN SAMPLES H41 H41/330 MOCK-UP H41 H41/410 QUALITY OF WORK H41 H41/440 MANUFACTURING ACCURACY H41 H41/450 GEL COATS TO EXTERNAL SURFACES H41 H41/460 LAMINATING H41 H41/470 BONDING OF CONSTITUENTS H41 H41/480 FIXINGS AND FASTENERS H41 H41/490 SEALING OF UNITS H41 H41/500 CURING H41 H41/505 METAL POWDER FINISH H41 H41/510 HARDNESS TESTING H41 H41/530 WEIGHT TESTING H41 H41/560 ADDITIONAL UNITS FOR DESTRUCTIVE TESTING H41 H41/570 PRODUCTION RECORDS H41 H41/580 RETENTION OF MOULDS AFTER PRODUCTION H41 H41/605 PREPARATION H41 H41/615 SUITABILITY OF STRUCTURE H41 H41/625 INSTALLATION OF INTERFACES H41 H41/630 ACCURACY OF ERECTION OF CLADDING H41 H41/635 ACCURACY OF ERECTION OF GRP COMPONENTS H41 H41/640 FINAL FIXING H41 H41/645 METALWORK H41 H41/650 SEALANT JOINTING SYSTEM H41 H41/655 SEALANT JOINTING PROPRIETARY SYSTEM H41 H41/660 OPEN DRAINED JOINTS H41 H41/680 CLEANING DOWN H41 H42 PRECAST CONCRETE PANEL CLADDING/ FEATURES H H42/10 INFORMATION TO BE PROVIDED WITH TENDER H42 H42/110 PRECAST H42 H42/115 PRECAST COMPOSITE H42 H42/205 CONTRACTOR'S DESIGN H42 H42/207 COMPLETION OF DESIGN H42 H42/209 STRUCTURAL DESIGN PROVIDED H42 H42/212 DESIGN PROPOSALS H42 H42/216 INFORMATION TO BE PROVIDED DURING DETAILED DESIGN H42 H42/217 QUALITY PLAN H42 H42/218 INFORMATION TO BE PROVIDED BEFORE COMMENCEMENT OF MANUFACTURE OF CLADDING PANELS H42 H42/222 FABRICATION SAMPLES H42 H42/224 MOCK-UP H42 H42/234 WEATHER RESISTANCE H42 H42/236 THERMAL PROPERTIES H42 H42/240 DURABILITY H42 H42/244 INITIAL SURFACE ABSORPTION H42 H42/261 COVER WHEN USING NATURAL STONE FACING H42 H42/270 DIMENSIONAL COORDINATION H42 H42/282 INSULATED PANELS - AVOIDANCE OF CONDENSATION H42 H42/284 INSULATED PANELS - AVOIDANCE OF INTERSTITIAL CONDENSATION H42 H42/286 ACOUSTIC PROPERTIES H42 H42/310 CONCRETE MIXES GENERALLY H42 H42/330 MIXES FOR VISIBLE FACES H42 H42/340 RECORDS FOR EACH MIX TYPE H42 H42/350 CONCRETE COMPRESSIVE STRENGTH TESTING AUTHORITY H42 H42/351 CONCRETE COMPRESSIVE STRENGTH TESTING AUTHORITY H42 H42/420 MANUFACTURING ACCURACY H42 H42/430 FIXINGS H42 H42/435 LIFTING POINTS H42 H42/440 REINFORCEMENT H42 H42/450 PLACING REINFORCEMENT. H42 H42/460 CONSISTENCY OF PRODUCTION H42 H42/470 PANELS WITH NATURAL STONE FACINGS H42 H42/480 CASTING AND CURING H42 H42/482 THERMAL INSULATION TO REAR OF PANELS H42 H42/484 THERMAL INSULATION WITHIN SANDWICH PANELS H42 H42/490 QUALITY OF FINISHES H42 H42/500 PRODUCTION CONTROL PANELS H42 H42/510 INSPECTION H42 H42/520 RECORDS H42 H42/610 INSTALLATION INSTRUCTIONS PROVIDED BY MANUFACTURER H42 H42/630 ACCURACY OF ERECTION H42 H42/640 FINAL FIXING H42 H42/650 MORTAR BEDDING TO PANELS ON SUPPORT STRUCTURE H42 H42/652 CEMENT:LIME:SAND MORTAR JOINTING TO NATURAL STONE FACINGS H42 H42/653 CEMENT:LIME:CRUSHED STONE MORTAR JOINTING TO NATURAL STONE FACINGS H42 H42/654 CEMENT:SAND MORTAR JOINTING TO NATURAL STONE FACINGS H42 H42/660 SEALANT JOINTS H42 H42/661 SEALANT JOINTS H42 H42/670 OPEN DRAINED JOINTS H42 H43 METAL COMPOSITE PANEL CLADDING/ COVERING H H43/110 METAL COMPOSITE PANEL H43 H43/120 METAL COMPOSITE PANEL H43 H43/130 METAL SEMI COMPOSITE PANEL H43 H43/150 GRP H43 H43/151 PVC-U H43 H43/155 POLYCARBONATE H43 H43/160 PLASTICS H43 H43/165 CONTRACTOR'S DESIGN H43 H43/167 COMPLETION OF DESIGN H43 H43/169 STRUCTURAL DESIGN PROVIDED H43 H43/172 THERMAL PERFORMANCE/ BRIDGING H43 H43/175 PRODUCT SAMPLES H43 H43/176 FASTENER SAMPLES H43 H43/185 PERFORMANCE COMPLIANCE H43 H43/187 DEFLECTION OF METAL CLADDING/ COVERING H43 H43/190 DEFLECTION OF PLASTICS CLADDING/ COVERING H43 H43/192 SOUND TRANSMITTANCE OF CLADDING/ COVERING SYSTEM - WEIGHTED H43 H43/193 SOUND TRANSMITTANCE OF CLADDING/ COVERING SYSTEM - FREQUENCY SPECIFIC H43 H43/194 INTERNAL SOUND ABSORPTION OF CLADDING/ COVERING SYSTEM H43 H43/198 WATER PENETRATION H43 H43/200 AVOIDANCE OF INTERSTITIAL CONDENSATION H43 H43/202 AVOIDANCE OF SURFACE CONDENSATION H43 H43/215 PAINTING STRUCTURE H43 H43/219 FASTENERS H43 H43/221 FITTINGS AND ACCESSORIES H43 H43/223 PREVENTION OF ELECTROLYTIC ACTION H43 H43/234 GUTTERS H43 H43/272 THERMAL INSULATION FOR SEMI-COMPOSITE PANEL CLADDING/ COVERING H43 H43/275 CONTINUITY THERMAL INSULATION H43 H43/300 PROFILE FILLERS GENERALLY H43 H43/310 PURPOSE MADE COLD FORMED METAL ACCESSORIES H43 H43/410 FIXING PANELS AND SHEETS GENERALLY H43 H43/419 FIXING PLASTICS CLADDING/ COVERING H43 H43/470 STRUCTURAL MOVEMENT JOINTS H43 H43/480 FLASHINGS/ TRIMS GENERALLY H43 H43/481 FLASHINGS/ TRIMS H43 H43/482 BUTT JOINTED FLASHINGS/ TRIMS H43 H43/540 ABUTMENTS H43 H43/550 SEALING EXTERNAL LAPS H43 H43/555 SEALING AT LAPS AND PENETRATIONS IN SEMI-COMPOSITE PANEL LININGS H43 H43/560 SAFETY SIGNS H43 H51 NATURAL STONE SLAB CLADDING/ LINING/ FEATURES H H51/10 INFORMATION TO BE PROVIDED WITH TENDER H51 H51/110 CLADDING TO H51 H51/205 CONTRACTOR'S DESIGN H51 H51/207 COMPLETION OF DESIGN H51 H51/209 STRUCTURAL DESIGN PROVIDED H51 H51/230 FIXINGS H51 H51/245 INFORMATION TO BE PROVIDED DURING DETAILED DESIGN H51 H51/247 QUALITY PLAN H51 H51/261 STONE SAMPLES H51 H51/271 FIXING SAMPLES H51 H51/281 CONTROL SAMPLES H51 H51/325 PRELIMINARY TEST INFORMATION H51 H51/326 ADDITIONAL PRELIMINARY TEST INFORMATION H51 H51/330 ACCURACY OF ERECTION H51 H51/405 TESTING AUTHORITY H51 H51/415 TESTING AUTHORITY H51 H51/425 STONE PRODUCTION TESTS H51 H51/435 SITE TESTING OF FIXINGS TO DETERMINE ULTIMATE LOAD H51 H51/445 SITE TESTING OF FIXINGS DURING INSTALLATION H51 H51/510 GENERALLY H51 H51/520 CUTTING OF STONE H51 H51/525 CUTTING OF STONE H51 H51/530 INSPECTION OF STONE UNITS H51 H51/540 SUITABILITY OF STRUCTURE H51 H51/550 INSTALLATION OF INTERFACES H51 H51/560 METALWORK H51 H51/570 WELDING H51 H51/580 FIXING H51 H51/585 CEMENT:LIME:SAND MORTAR JOINTING H51 H51/590 CEMENT:LIME:CRUSHED STONE MORTAR JOINTING H51 H51/595 CEMENT:SAND:MORTAR JOINTING H51 H51/600 SEALANT JOINTING H51 H51/610 SEALANT JOINTING H51 H51/620 SEALANT MOVEMENT/OTHER JOINTS H51 H51/630 SEALANT MOVEMENT/ OTHER JOINTS H51 H60 PLAIN ROOF TILING H H60/105 CLAY ROOF TILING H60 H60/110 CLAY ROOF TILING WITH COUNTERBATTENS H60 H60/120 CONCRETE ROOF TILING H60 H60/125 CONCRETE ROOF TILING WITH COUNTERBATTENS H60 H60/145 CLAY VERTICAL TILING H60 H60/155 CONCRETE VERTICAL TILING H60 H60/210 BASIC WORKMANSHIP H60 H60/220 REMOVE EXISTING TILING H60 H60/230 MINERAL WOOL INSULATION ON STRUCTURAL METAL LINER TRAYS H60 H60/240 UNDERLAY H60 H60/245 BATTENS/ COUNTERBATTENS - TREATED H60 H60/247 BATTENS/ COUNTERBATTENS - UNTREATED H60 H60/255 COUNTERBATTENS ON RIGID SARKING H60 H60/257 COUNTERBATTENS ON STRUCTURAL METAL LINER TRAYS H60 H60/259 COUNTERBATTENS ON RAFTERS H60 H60/265 BATTEN FIXING H60 H60/270 BATTENS FIXED TO MASONRY H60 H60/272 TIMBER FOR TILING SUBSTRATE WORK H60 H60/275 TILE FIXING H60 H60/280 LOCAL AND GENERAL FIXING AREAS H60 H60/290 MORTAR BEDDING/ POINTING H60 H60/305 GENERALLY H60 H60/325 FIRE SEPARATING WALLS H60 H60/345 VENTILATED EAVES WITH INTEGRATED GRILLES/ TRAYS H60 H60/355 VENTILATED EAVES WITH SEPARATED GRILLES/ TRAYS H60 H60/365 UNVENTILATED EAVES H60 H60/435 CLOAKED VERGES H60 H60/445 MORTAR BEDDED VERGES WITH BEDDED UNDERCLOAK H60 H60/455 MORTAR BEDDED VERGES WITH NAILED UNDERCLOAK H60 H60/525 MITRED HIPS H60 H60/555 MORTAR BEDDED HIPS H60 H60/565 MORTAR BEDDED AND MECHANICALLY FIXED HIPS H60 H60/585 ARRIS HIPS H60 H60/595 BONNET HIPS H60 H60/605 GRP VALLEYS H60 H60/615 METAL VALLEYS H60 H60/625 CURVED PLAIN TILE VALLEYS H60 H60/635 MITRED VALLEYS H60 H60/645 LACED VALLEYS H60 H60/650 SWEPT VALLEYS H60 H60/660 SIDE ABUTMENTS H60 H60/670 TOP EDGE ABUTMENTS H60 H60/675 TOP EDGE VENTILATED ABUTMENTS H60 H60/690 ROOF WINDOWS H60 H60/700 DRY VENTILATED RIDGES H60 H60/710 DRY RIDGES H60 H60/740 MORTAR BEDDED RIDGES H60 H60/750 MORTAR BEDDED AND MECHANICALLY FIXED RIDGES H60 H60/770 DRY VENTILATED MONO-RIDGES H60 H60/775 DRY MONO-RIDGES H60 H60/780 MORTAR BEDDED MONO-RIDGES H60 H60/800 CHANGE OF ROOF PITCH H60 H60/840 VENTILATOR TILES H60 H60/850 ROOF SLOPE TERMINALS H60 H60/860 PHOTOVOLTAIC MODULES H60 H60/870 SUNDRY ACCESSORIES H60 H60/910 BOTTOM EDGES H60 H60/920 TOP EDGES H60 H60/930 SIDE ABUTMENTS H60 H60/940 ANGLES WITH ANGLE TILES H60 H60/950 ANGLES WITH SOAKERS H60 H60/960 JUNCTIONS WITH ROOF VERGES H60 H61 FIBRE CEMENT SLATING H H61/105 ROOF SLATING H61 H61/110 ROOF SLATING WITH COUNTERBATTENS H61 H61/120 VERTICAL SLATING H61 H61/210 BASIC WORKMANSHIP H61 H61/220 REMOVING EXISTING SLATING H61 H61/230 MINERAL WOOL INSULATION ON STRUCTURAL METAL LINER TRAYS H61 H61/240 UNDERLAY H61 H61/245 BATTENS/ COUNTERBATTENS - TREATED H61 H61/247 BATTENS/ COUNTERBATTENS - UNTREATED H61 H61/255 COUNTERBATTENS ON RIGID SARKING H61 H61/257 COUNTERBATTENS ON STRUCTURAL METAL LINER TRAYS H61 H61/259 COUNTERBATTENS ON RAFTERS H61 H61/265 BATTEN FIXING H61 H61/270 BATTENS FIXED TO MASONRY H61 H61/275 SLATE FIXING H61 H61/290 MORTAR BEDDING/ POINTING H61 H61/305 GENERALLY H61 H61/325 FIRE SEPARATING WALLS H61 H61/345 VENTILATED EAVES WITH INTEGRATED GRILLES/ TRAYS H61 H61/355 VENTILATED EAVES WITH SEPARATED GRILLES/ TRAYS H61 H61/365 UNVENTILATED EAVES H61 H61/405 DRY (CLOSED) VERGES H61 H61/445 MORTAR BEDDED VERGES WITH BEDDED UNDERCLOAK H61 H61/455 MORTAR BEDDED VERGES WITH NAILED UNDERCLOAK H61 H61/505 DRY CAPPED HIPS H61 H61/525 MITRED HIPS H61 H61/535 LEAD ROLL HIPS H61 H61/555 MORTAR BEDDED TILE HIPS H61 H61/565 MORTAR BEDDED AND MECHANICALLY FIXED TILE HIPS H61 H61/605 GRP VALLEYS H61 H61/615 METAL VALLEYS H61 H61/635 MITRED VALLEYS H61 H61/660 SIDE ABUTMENTS H61 H61/670 TOP EDGE ABUTMENTS H61 H61/675 TOP EDGE VENTILATED ABUTMENTS H61 H61/690 ROOF WINDOWS H61 H61/700 DRY VENTILATED TILE RIDGES H61 H61/705 DRY VENTILATED CAPPED RIDGES H61 H61/710 DRY CAPPED RIDGES H61 H61/730 LEAD ROLL RIDGES H61 H61/740 MORTAR BEDDED TILE RIDGES H61 H61/750 MORTAR BEDDED AND MECHANICALLY FIXED TILE RIDGES H61 H61/770 DRY VENTILATED TILE MONO-RIDGES H61 H61/772 DRY VENTILATED CAPPED MONO-RIDGES H61 H61/775 DRY CAPPED MONO-RIDGES H61 H61/780 MORTAR BEDDED TILE MONO-RIDGES H61 H61/800 CHANGE OF ROOF PITCH H61 H61/840 VENTILATOR SLATES H61 H61/850 ROOF SLOPE TERMINALS H61 H61/860 PHOTOVOLTAIC MODULES H61 H61/870 SUNDRY ACCESSORIES H61 H61/910 BOTTOM EDGES H61 H61/920 TOP EDGES H61 H61/930 SIDE ABUTMENTS H61 H61/950 ANGLES WITH SOAKERS H61 H61/960 JUNCTIONS WITH ROOF VERGES H61 H62 NATURAL SLATING H H62/105 ROOF SLATING H62 H62/110 ROOF SLATING WITH COUNTERBATTENS H62 H62/120 VERTICAL SLATING H62 H62/125 ROOF SLATING H62 H62/130 ROOF SLATING WITH COUNTERBATTENS H62 H62/140 VERTICAL SLATING H62 H62/145 ROOF SLATING H62 H62/150 ROOF SLATING WITH COUNTERBATTENS H62 H62/210 BASIC WORKMANSHIP H62 H62/220 REMOVING EXISTING SLATING H62 H62/230 MINERAL WOOL INSULATION ON STRUCTURAL METAL LINER TRAYS H62 H62/240 UNDERLAY H62 H62/245 BATTENS/ COUNTERBATTENS - TREATED H62 H62/247 BATTENS/ COUNTERBATTENS - UNTREATED H62 H62/255 COUNTERBATTENS ON RIGID SARKING H62 H62/257 COUNTERBATTENS ON STRUCTURAL METAL LINER TRAYS H62 H62/259 COUNTERBATTENS ON RAFTERS H62 H62/265 BATTEN FIXING H62 H62/270 BATTENS FIXED TO MASONRY H62 H62/272 TIMBER FOR SLATING SUBSTRATE WORK H62 H62/275 SLATE FIXING H62 H62/280 SLATES - PERFORMANCE SPECIFICATION H62 H62/290 MORTAR BEDDING/ POINTING H62 H62/305 GENERALLY H62 H62/325 FIRE SEPARATING WALLS H62 H62/345 VENTILATED EAVES WITH INTEGRATED GRILLES TRAY H62 H62/355 VENTILATED EAVES WITH SEPARATED GRILLES/ TRAYS H62 H62/365 UNVENTILATED EAVES H62 H62/445 MORTAR BEDDED VERGES WITH BEDDED UNDERCLOAK H62 H62/455 MORTAR BEDDED VERGES WITH NAILED UNDERCLOAK H62 H62/525 MITRED HIPS H62 H62/535 LEAD ROLL HIPS H62 H62/555 MORTAR BEDDED TILE HIPS H62 H62/565 MORTAR BEDDED AND MECHANICALLY FIXED TILE HIPS H62 H62/605 GRP VALLEYS H62 H62/615 METAL VALLEYS H62 H62/635 MITRED VALLEYS H62 H62/645 LACED VALLEYS H62 H62/650 SWEPT VALLEYS H62 H62/660 SIDE ABUTMENTS H62 H62/670 TOP EDGE ABUTMENTS H62 H62/675 TOP EDGE VENTILATED ABUTMENTS H62 H62/690 ROOF WINDOWS H62 H62/700 DRY VENTILATED TILE RIDGES H62 H62/730 LEAD ROLL RIDGES H62 H62/740 MORTAR BEDDED TILE RIDGES H62 H62/750 MORTAR BEDDED AND MECHANICALLY FIXED TILE RIDGES H62 H62/770 DRY VENTILATED TILE MONO-RIDGES H62 H62/780 MORTAR BEDDED TILE MONO-RIDGES H62 H62/800 CHANGE OF ROOF PITCH H62 H62/840 VENTILATOR SLATES H62 H62/850 ROOF SLOPE TERMINALS H62 H62/860 PHOTOVOLTAIC MODULES H62 H62/870 SUNDRY ACCESSORIES H62 H62/910 BOTTOM EDGES H62 H62/920 TOP EDGES H62 H62/930 SIDE ABUTMENTS H62 H62/950 ANGLES WITH SOAKERS H62 H62/960 JUNCTION WITH ROOF VERGES H62 H64 WOOD SHINGLE AND SHAKE ROOFING H H64/110 WOOD SHINGLE/ SHAKE ROOFING H64 H64/120 WOOD SHINGLE/ SHAKE ROOFING WITH COUNTERBATTENS H64 H64/130 VERTICAL WOOD SHINGLE/ SHAKES H64 H64/305 MINERAL WOOL INSULATION ON STRUCTURAL METAL LINER TRAYS H64 H64/310 BATTENS/ COUNTERBATTENS - TREATED H64 H64/315 BATTENS/ COUNTERBATTENS - UNTREATED H64 H64/320 EAVES UNDERLAY SUPPORTS H64 H64/325 EAVES VENTS H64 H64/330 EAVES VENTILATOR TRAYS H64 H64/335 COUNTERBATTEN CLOSERS H64 H64/340 PRE-FORMED HIP CAPS H64 H64/345 PRE-FORMED RIDGE CAPS H64 H64/350 GRP VALLEYS H64 H64/355 RIDGE TERMINALS H64 H64/360 ROOF SLOPE VENTILATORS H64 H64/365 ROOF SLOPE TERMINALS H64 H64/605 BASIC WORKMANSHIP H64 H64/610 REMOVING EXISTING H64 H64/615 FIRE SEPARATING WALLS H64 H64/620 LAYING MINERAL WOOL INSULATION ON STRUCTURAL METAL LINER TRAYS H64 H64/625 LAYING UNDERLAY H64 H64/630 LAYING UNDERLAY AS INTERLAY TO SHAKES H64 H64/635 FIXING COUNTERBATTENS ON RIGID SARKING H64 H64/640 FIXING COUNTERBATTENS ON STRUCTURAL METAL LINER TRAYS H64 H64/645 FIXING COUNTERBATTENS ON RAFTERS H64 H64/650 FIXING ROOFING BATTENS H64 H64/655 FIXING BATTENS FOR VERTICAL SHINGLES/ SHAKES H64 H64/660 FIXING SHINGLES/ SHAKES H64 H64/665 VENTILATED EAVES FOR COLD ROOF CONSTRUCTION H64 H64/670 VENTILATED EAVES FOR WARM ROOF CONSTRUCTION H64 H64/675 VERGES H64 H64/680 HIPS H64 H64/685 LAYING GRP VALLEYS H64 H64/690 LAYING METAL VALLEYS H64 H64/695 SIDE ABUTMENTS H64 H64/697 TOP EDGE ABUTMENTS H64 H64/700 ROOF WINDOW PERIMETERS H64 H64/705 RIDGES H64 H64/710 VENTILATED RIDGES H64 H64/715 MONO-RIDGES H64 H64/720 VENTILATED MONO-RIDGES H64 H64/725 CHANGE OF ROOF PITCH H64 H64/730 INSTALLING ROOF SLOPE VENTILATORS H64 H64/735 INSTALLING ROOF SLOPE TERMINALS H64 H64/740 VERTICAL SHINGLES/ SHAKES - BOTTOM EDGES H64 H64/745 VERTICAL SHINGLES/ SHAKES - TOP EDGES H64 H64/750 VERTICAL SHINGLES/ SHAKES - SIDE ABUTMENTS H64 H64/755 VERTICAL SHINGLES/ SHAKES - INTERNAL AND EXTERNAL CORNERS H64 H64/760 VERTICAL SHINGLES/ SHAKES - JUNCTIONS WITH ROOF VERGES H64 H64/765 SUNDRY ACCESSORIES H64 H64/910 COMPLETION H64 H65 SINGLE LAP ROOF TILING H H65/105 CLAY ROOF TILING H65 H65/110 CLAY ROOF TILING WITH COUNTERBATTENS H65 H65/115 CONCRETE ROOF TILING H65 H65/120 CONCRETE ROOF TILING WITH COUNTERBATTENS H65 H65/125 RECONSTITUTED SLATE ROOF TILING H65 H65/130 RECONSTITUTED SLATE ROOF TILING WITH COUNTERBATTENS H65 H65/135 CERAMIC SLATE ROOF TILING H65 H65/140 CERAMIC SLATE ROOF TILING WITH COUNTERBATTENS H65 H65/210 BASIC WORKMANSHIP H65 H65/220 REMOVING EXISTING TILING H65 H65/230 MINERAL WOOL INSULATION ON STRUCTURAL METAL LINER TRAYS H65 H65/240 UNDERLAY H65 H65/245 BATTENS/ COUNTERBATTENS - TREATED H65 H65/247 BATTENS/ COUNTERBATTENS - UNTREATED H65 H65/255 COUNTERBATTENS ON RIGID SARKING H65 H65/257 COUNTERBATTENS ON STRUCTURAL METAL LINER TRAYS H65 H65/259 COUNTERBATTENS ON RAFTERS H65 H65/265 BATTEN FIXING H65 H65/275 TILE FIXING H65 H65/280 LOCAL AND GENERAL FIXING AREAS H65 H65/290 MORTAR BEDDING/ POINTING H65 H65/295 MORTAR BEDDED DENTIL COURSES H65 H65/305 GENERALLY H65 H65/325 FIRE SEPARATING WALLS H65 H65/345 VENTILATED EAVES - INTEGRATED GRILLES/ TRAYS H65 H65/355 VENTILATED EAVES - SEPARATED GRILLES/ TRAYS H65 H65/365 EAVES H65 H65/405 DRY VERGES H65 H65/435 CLOAKED VERGES H65 H65/445 MORTAR BEDDED VERGES WITH BEDDED UNDERCLOAK H65 H65/455 MORTAR BEDDED VERGES WITH NAILED UNDERCLOAK H65 H65/505 DRY HIPS H65 H65/525 MITRED HIPS H65 H65/535 LEAD ROLL HIPS H65 H65/555 MORTAR BEDDED HIPS H65 H65/560 MORTAR BEDDED AND MECHANICALLY FIXED HIPS H65 H65/605 GRP VALLEYS H65 H65/615 METAL VALLEYS H65 H65/625 TROUGH VALLEYS H65 H65/660 SIDE ABUTMENTS H65 H65/670 TOP EDGE ABUTMENTS H65 H65/675 TOP EDGE VENTILATED ABUTMENTS H65 H65/690 ROOF WINDOWS H65 H65/700 DRY VENTILATED RIDGES H65 H65/710 DRY RIDGES H65 H65/730 LEAD ROLL RIDGES H65 H65/740 MORTAR BEDDED RIDGES H65 H65/750 MORTAR BEDDED AND MECHANICALLY FIXED RIDGES H65 H65/770 DRY VENTILATED MONO-RIDGES H65 H65/775 DRY MONO-RIDGES H65 H65/780 MORTAR BEDDED MONO-RIDGES H65 H65/800 CHANGE OF ROOF PITCH H65 H65/840 VENTILATOR TILES H65 H65/850 ROOF SLOPE TERMINALS H65 H65/860 PHOTVOLTAIC MODULES H65 H65/870 SUNDRY ACCESSORIES H65 H67 METAL SINGLE LAP ROOF TILING H H67/110 METAL ROOF TILING H67 H67/120 METAL ROOF TILING WITH COUNTERBATTENS H67 H67/130 METAL VERTICAL TILING H67 H67/305 MINERAL WOOL INSULATION ON STRUCTURAL METAL LINER TRAYS H67 H67/310 BATTENS/ COUNTERBATTENS - TREATED H67 H67/315 BATTENS/ COUNTERBATTENS - UNTREATED H67 H67/320 EAVES UNDERLAY SUPPORTS H67 H67/325 EAVES VENTS H67 H67/330 EAVES VENTILATOR TRAYS H67 H67/335 VERGE CAPS H67 H67/340 HIP CAPS H67 H67/345 GRP VALLEYS H67 H67/355 SIDE ABUTMENT METAL PROFILE UPSTANDS H67 H67/360 TOP ABUTMENT METAL PROFILE UPSTANDS H67 H67/365 ROOF HATCHES H67 H67/370 ROOF WINDOWS H67 H67/375 RIDGE CAPS H67 H67/380 MONO-RIDGE CAPS H67 H67/385 STRIP VENTILATORS H67 H67/390 RIDGE TERMINALS H67 H67/395 ROOF SLOPE VENTILATORS H67 H67/400 ROOF SLOPE TERMINALS H67 H67/605 BASIC WORKMANSHIP H67 H67/610 REMOVING EXISTING TILING H67 H67/615 FIRE SEPARATING WALLS H67 H67/620 LAYING MINERAL WOOL INSULATION ON STRUCTURAL METAL LINER TRAYS H67 H67/625 LAYING UNDERLAY H67 H67/630 FIXING COUNTERBATTENS ON RIGID SARKING H67 H67/635 FIXING COUNTERBATTENS ON STRUCTURAL METAL LINER TRAYS H67 H67/640 FIXING COUNTERBATTENS ON RAFTERS H67 H67/645 FIXING BATTENS - ROOF TILING H67 H67/650 FIXING BATTENS - VERTICAL TILING H67 H67/655 FIXING METAL TILES H67 H67/660 VENTILATED EAVES FOR COLD ROOF CONSTRUCTION H67 H67/665 VENTILATED EAVES FOR WARM ROOF CONSTRUCTION H67 H67/670 VERGES H67 H67/675 HIPS H67 H67/680 VENTILATED HIPS H67 H67/685 FIXING ARRIS BATTENS H67 H67/690 LAYING GRP VALLEY H67 H67/695 LAYING METAL VALLEY H67 H67/700 SIDE ABUTMENTS WITH METAL PROFILE UPSTAND H67 H67/705 SIDE ABUTMENTS H67 H67/710 TOP ABUTMENTS WITH METAL PROFILE UPSTAND H67 H67/715 TOP ABUTMENTS H67 H67/720 VENTILATED TOP ABUTMENTS WITH METAL PROFILE UPSTAND H67 H67/725 ROOF HATCHES/ WINDOW PERIMETERS H67 H67/730 ROOF WINDOW PERIMETERS H67 H67/735 RIDGES H67 H67/740 VENTILATED RIDGES H67 H67/745 VENTILATED RIDGES WITH VENT FIXED UNDER RIDGE FIXING BATTEN H67 H67/750 INSTALLING RIDGE TERMINALS H67 H67/755 MONO-RIDGES H67 H67/760 VENTILATED MONO-RIDGES H67 H67/765 INSTALLING ROOF SLOPE VENTILATORS H67 H67/770 CHANGE OF ROOF PITCHES H67 H67/775 INSTALLING ROOF SLOPE TERMINALS H67 H67/780 VERTICAL METAL TILING - BOTTOM EDGES H67 H67/785 VERTICAL METAL TILING - TOP EDGES H67 H67/790 VERTICAL METAL TILING - SIDE ABUTMENTS H67 H67/795 VERTICAL METAL TILING - JUNCTIONS AT WINDOW REVEALS H67 H67/800 VERTICAL METAL TILING - EXTERNAL CORNERS WITH RIDGE CAPS H67 H67/805 VERTICAL METAL TILING - INTERNAL CORNERS WITH FLASHINGS H67 H67/810 VERTICAL METAL TILING - JUNCTIONS WITH ROOF VERGES H67 H67/815 SUNDRY ACCESSORIES H67 H67/910 COMPLETION H67 H71 LEAD SHEET COVERINGS/ FLASHINGS H H71/110 ROOFING H71 H71/130 CLADDING H71 H71/150 DORMERS H71 H71/160 LEAD COVERED ROOFING PANELS H71 H71/170 LEAD COVERED CLADDING PANELS H71 H71/180 LEAD WRAPPED PANELS H71 H71/200 GUTTER LINING H71 H71/210 GUTTER LINING WITH PROPRIETARY EXPANSION JOINTS H71 H71/230 VALLEY GUTTER LINING TO SLATE/ TILE ROOFS H71 H71/235 VALLEY GUTTER LINING TO LEAD ROOFS H71 H71/240 VALLEY GUTTER LINING TO LEAD ROOFS H71 H71/250 WEATHERING TO H71 H71/310 RIDGE/ HIP ROLLS TO LEAD ROOFS H71 H71/315 RIDGE/ HIP ROLLS TO SLATE ROOFS H71 H71/322 SOAKERS FOR MITRED HIPS TO SLATE/ PLAIN TILE ROOFS H71 H71/324 SOAKERS FOR MITRED VALLEYS TO SLATE ROOFTS H71 H71/325 SOAKERS FOR MITRED VALLEYS TO SLATE/ PLAIN TILE ROOFS H71 H71/326 SOAKERS FOR SWEPT VALLEYS TO PLAIN TILE ROOFS H71 H71/410 APRON FLASHINGS H71 H71/420 COVER FLASHINGS H71 H71/430 COVER FLASHINGS H71 H71/440 SOAKERS AND STEP FLASHINGS H71 H71/450 STEP AND COVER FLASHINGS H71 H71/452 SINGLE STEP AND COVER FLASHINGS H71 H71/454 SINGLE STEP FLASHINGS H71 H71/456 STEP FLASHINGS WITH SECRET GUTTER H71 H71/458 STEP AND COVER FLASHING WITH SECRET GUTTER H71 H71/460 CHANGE OF ROOF PITCH FLASHINGS H71 H71/470 FLASHINGS H71 H71/472 CHIMNEY FLASHINGS TO SLATE/ PLAIN TILE ROOFS H71 H71/474 CHIMNEY FLASHINGS TO SINGLE LAP TILE ROOFS H71 H71/476 CHIMNEY DAMP PROOF COURSE H71 H71/478 CHIMNEY DAMP PROOF COURSE H71 H71/480 LEAD SLATES H71 H71/490 VERTICAL TILING/ SLATING BOTTOM EDGE FLASHINGS H71 H71/492 VERTICAL TILING/ SLATING TOP EDGE FLASHINGS H71 H71/494 VERTICAL TILING/ SLATING SIDE ABUTMENT STEP FLASHINGS H71 H71/496 VERTICAL TILING/ SLATING ANGLE SOAKERS H71 H71/497 LEAD DAMP PROOF COURSE/ CAVITY TRAY AT RAKING ABUTMENTS H71 H71/498 COMBINED LEAD DAMP PROOF COURSE/ CAVITY TRAY AND COVER FLASHING AT HORIZONTAL ABUTMENTS H71 H71/510 WORKMANSHIP GENERALLY H71 H71/515 LEADWELDING H71 H71/516 LEADWELDING H71 H71/520 LEAD SHEET H71 H71/550 LIGHTNING PROTECTION H71 H71/555 LAYOUT H71 H71/560 CONTROL SAMPLES H71 H71/565 MOCK-UP H71 H71/570 EXISTING METAL RETAINED H71 H71/580 EXISTING METAL REUSED H71 H71/585 EXISTING METAL REMOVED TO REMAIN THE PROPERTY OF THE EMPLOYER H71 H71/610 SUITABILITY OF SUBSTRATES H71 H71/620 PREPARATION OF EXISTING TIMBER SUBSTRATES H71 H71/630 PLYWOOD UNDERLAY H71 H71/640 TIMBER FOR USE WITH LEADWORK H71 H71/645 NEEDLE PUNCHED NONWOVEN POLYESTER GEOTEXTILE UNDERLAY H71 H71/650 LAYING UNDERLAY H71 H71/705 HEAD FIXING LEAD SHEET H71 H71/710 FIXINGS H71 H71/715 CLIPS H71 H71/760 CONTINUOUS CLIPS H71 H71/765 CONTINUOUS CLIPS FOR CROSS JOINTS IN ROOFING H71 H71/770 WEDGE FIXING INTO JOINTS/ CHASES H71 H71/780 WEDGE FIXING INTO DAMP PROOF COURSE JOINTS H71 H71/790 SCREW FIXING INTO JOINTS/ CHASES H71 H71/810 FORMING DETAILS H71 H71/830 STANDING SEAM JOINTS H71 H71/840 WOOD CORED ROLL JOINTS WITHOUT SPLASH LAP H71 H71/845 WOOD CORED ROLL JOINTS WITH SPLASH LAP H71 H71/847 HOLLOW ROLL JOINTS H71 H71/860 DRIPS WITH SPLASH LAPS H71 H71/862 DRIPS WITH SPLASH LAPS H71 H71/865 DRIPS WITHOUT SPLASH LAPS H71 H71/880 WELTED JOINTS H71 H71/950 PLAQUES - EXISTING H71 H71/955 PLAQUES - NEW H71 H71/970 PATINATION OIL H71 H72 ALUMINIUM STRIP/ SHEET COVERINGS/ FLASHINGS H H72/110 ROOFING H72 H72/130 CLADDING H72 H72/150 DORMERS H72 H72/210 GUTTER LINING WITH PROPRIETARY EXPANSION JOINTS H72 H72/230 VALLEY GUTTER LINING TO SLATE/ TILE ROOFS H72 H72/240 RECESSED VALLEY GUTTER LINING H72 H72/245 VALLEY GUTTER LINING H72 H72/250 WEATHERING TO H72 H72/310 RIDGE/ HIP BATTEN ROLLS H72 H72/340 STANDING SEAM EAVES H72 H72/350 BATTEN ROLL EAVES H72 H72/370 STANDING SEAM VERGE H72 H72/380 BATTEN ROLL VERGE H72 H72/410 APRON FLASHINGS H72 H72/420 COVER FLASHINGS H72 H72/430 STEP FLASHINGS H72 H72/440 SOAKERS AND STEP FLASHINGS H72 H72/450 STEP AND COVER FLASHINGS H72 H72/460 CHANGE OF ROOF PITCH FLASHINGS H72 H72/470 MISCELLANEOUS FLASHINGS H72 H72/510 WORKMANSHIP GENERALLY H72 H72/515 WELDING H72 H72/516 WELDING H72 H72/520 ALUMINIUM STRIP/ SHEET H72 H72/525 COATED ALUMINIUM STRIP/ SHEET H72 H72/530 INTEGRITY OF ALUMINIUM H72 H72/535 INTEGRITY OF ALUMINIUM H72 H72/550 LIGHTNING PROTECTION H72 H72/555 LAYOUT H72 H72/560 CONTROL SAMPLES H72 H72/565 MOCK-UP H72 H72/570 EXISTING METAL RETAINED H72 H72/580 EXISTING METAL REUSED H72 H72/585 EXISTING METAL REMOVED TO REMAIN THE PROPERTY OF THE EMPLOYER H72 H72/610 SUITABILITY OF SUBSTRATES H72 H72/620 PREPARATION OF EXISTING TIMBER SUBSTRATES H72 H72/630 PLYWOOD UNDERLAY H72 H72/640 TIMBER FOR USE WITH ALUMINIUM WORK H72 H72/645 NEEDLE PUNCHED NONWOVEN POLYESTER GEOTEXTILE UNDERLAY H72 H72/650 LAYING UNDERLAY H72 H72/710 FIXINGS FOR CLIPS H72 H72/720 STANDING SEAM FIXED CLIPS H72 H72/725 STANDING SEAM SLIDING CLIPS H72 H72/730 BATTEN ROLL CLIPS H72 H72/750 CLIPS FOR FLASHINGS/ CROSS JOINTS H72 H72/760 CONTINUOUS CLIPS H72 H72/770 WEDGE FIXING INTO JOINTS/ CHASES H72 H72/780 WEDGE FIXING INTO DAMP PROOF COURSE JOINTS H72 H72/790 SCREW FIXING INTO JOINTS/ CHASES H72 H72/810 FORMING DETAILS H72 H72/815 FREE EDGE DETAILS H72 H72/830 STANDING SEAM JOINTS H72 H72/840 BATTEN ROLL JOINTS H72 H72/860 DRIP/ STEP JOINTS H72 H72/880 SINGLE LOCK WELT JOINTS H72 H72/890 DOUBLE LOCK WELT JOINTS H72 H73 COPPER STRIP/ SHEET COVERINGS/ FLASHINGS H H73/110 ROOFING H73 H73/130 CLADDING H73 H73/150 DORMERS H73 H73/210 GUTTER LINING WITH PROPRIETARY EXPANSION JOINTS H73 H73/220 GUTTER LINING WITH DRIPS H73 H73/230 VALLEY GUTTER LINING TO SLATE/ TILE ROOFS H73 H73/240 RECESSED VALLEY GUTTER LINING H73 H73/245 VALLEY GUTTER LINING H73 H73/250 WEATHERING TO H73 H73/310 RIDGE/ HIP BATTEN ROLLS H73 H73/320 RIDGE/ HIP STANDING SEAMS H73 H73/340 STANDING SEAM EAVES WITH CLOSED ENDS H73 H73/345 STANDING SEAM EAVES WITH FOLDED DOWN ENDS H73 H73/350 BATTEN ROLL EAVES H73 H73/360 WELTED VERGE H73 H73/370 STANDING SEAM VERGE H73 H73/380 BATTEN ROLL VERGE H73 H73/405 SOAKERS FOR H73 H73/410 APRON FLASHINGS H73 H73/420 COVER FLASHINGS H73 H73/440 SOAKERS AND STEP FLASHINGS H73 H73/450 STEP AND COVER FLASHINGS H73 H73/455 STEP FLASHINGS WITH SECRET GUTTER H73 H73/460 CHANGE OF ROOF PITCH FLASHINGS H73 H73/470 FLASHINGS H73 H73/475 CHIMNEY FLASHINGS H73 H73/476 CHIMNEY FLASHINGS H73 H73/480 COPPER SLATES H73 H73/490 VERTICAL TILING/ SLATING BOTTOM EDGE FLASHINGS H73 H73/492 VERTICAL TILING/ SLATING TOP EDGE FLASHINGS H73 H73/494 VERTICAL TILING/ SLATING SIDE ABUTMENT STEP FLASHINGS H73 H73/496 VERTICAL TILING/ SLATING ANGLE SOAKERS H73 H73/510 WORKMANSHIP GENERALLY H73 H73/515 SOLDERING AND BRAZING H73 H73/516 SOLDERING AND BRAZING H73 H73/520 COPPER STRIP/ SHEET H73 H73/530 INTEGRITY OF COPPER H73 H73/535 INTEGRITY OF COPPER H73 H73/550 LIGHTNING PROTECTION H73 H73/555 LAYOUT H73 H73/560 CONTROL SAMPLES H73 H73/565 MOCK-UP H73 H73/570 EXISTING METAL RETAINED H73 H73/580 EXISTING METAL REUSED H73 H73/585 EXISTING METAL REMOVED TO REMAIN THE PROPERTY OF THE EMPLOYER H73 H73/610 SUITABILITY OF SUBSTRATES H73 H73/620 PREPARATION OF EXISTING TIMBER SUBSTRATES H73 H73/630 PLYWOOD UNDERLAY H73 H73/640 TIMBER FOR USE WITH COPPER WORK H73 H73/645 NEEDLE PUNCHED NONWOVEN POLYESTER GEOTEXTILE UNDERLAY H73 H73/650 LAYING UNDERLAY H73 H73/655 LAYING UNDERLAY H73 H73/710 FIXINGS FOR CLIPS H73 H73/720 STANDING SEAM FIXED CLIPS H73 H73/725 STANDING SEAM SLIDING CLIPS H73 H73/730 BATTEN ROLL CLIPS H73 H73/740 RIDGE/ HIP BATTEN ROLL CLIPS H73 H73/750 CLIPS FOR FLASHINGS/ CROSS JOINTS H73 H73/760 CONTINUOUS CLIPS (CLEATS) H73 H73/770 WEDGE FIXING INTO JOINTS/ CHASES H73 H73/780 WEDGE FIXING INTO DAMP PROOF COURSE JOINTS H73 H73/790 SCREW FIXING INTO JOINTS/ CHASES H73 H73/810 FORMING DETAILS H73 H73/830 STANDING SEAM JOINTS H73 H73/835 ANGLE STANDING SEAM JOINTS H73 H73/840 BATTEN ROLL JOINTS H73 H73/860 DRIP/ STEP JOINTS H73 H73/880 SINGLE LOCK WELT JOINTS H73 H73/885 SINGLE LOCK WELT WITH ADDITIONAL WELT JOINTS H73 H73/890 DOUBLE LOCK WELT JOINTS H73 H73/950 PLAQUES H73 H73/955 PLAQUES H73 H74 ZINC STRIP/ SHEET COVERINGS/ FLASHINGS H H74/110 ROOFING H74 H74/130 CLADDING H74 H74/150 DORMERS H74 H74/210 GUTTER LINING WITH PROPRIETARY EXPANSION JOINTS H74 H74/220 GUTTER LINING WITH SADDLE EXPANSION JOINTS H74 H74/230 VALLEY GUTTER LINING TO SLATE/ TILE ROOFS H74 H74/240 RECESSED VALLEY GUTTER LINING H74 H74/245 VALLEY GUTTER LINING H74 H74/250 WEATHERING TO H74 H74/310 RIDGE/ HIP ROLL CAPS H74 H74/320 RIDGE/ HIP STANDING SEAMS H74 H74/340 STANDING SEAM EAVES WITH CLOSED ENDS H74 H74/345 STANDING SEAM EAVES WITH FOLDED DOWN ENDS H74 H74/350 ROLL CAP EAVES WITH SQUARED AND SOLDERED ENDS H74 H74/355 ROLL CAP EAVES WITH SPLAYED AND FOLDED ENDS H74 H74/370 STANDING SEAM VERGE H74 H74/380 ROLL CAP VERGE H74 H74/410 APRON FLASHINGS H74 H74/420 COVER FLASHINGS H74 H74/430 STEP FLASHINGS H74 H74/440 SOAKERS AND STEP FLASHINGS H74 H74/450 STEP AND COVER FLASHINGS H74 H74/460 CHANGE OF ROOF PITCH FLASHINGS H74 H74/470 MISCELLANEOUS FLASHINGS H74 H74/510 WORKMANSHIP GENERALLY H74 H74/515 SOLDERING AND NAKED FLAME PREHEATING H74 H74/516 SOLDERING AND NAKED FLAME PREHEATING H74 H74/520 ZINC STRIP/ SHEET - STANDARD TEMPER ALLOY H74 H74/525 ZINC STRIP - SOFT TEMPER ALLOY H74 H74/530 INTEGRITY OF ZINC H74 H74/535 INTEGRITY OF ZINC H74 H74/550 LIGHTNING PROTECTION H74 H74/555 LAYOUT H74 H74/560 CONTROL SAMPLES H74 H74/565 MOCK-UP H74 H74/570 EXISTING METAL RETAINED H74 H74/580 EXISTING METAL REUSED H74 H74/585 EXISTING METAL REMOVED TO REMAIN THE PROPERTY OF THE EMPLOYER H74 H74/610 SUITABILITY OF SUBSTRATES H74 H74/620 PREPARATION OF EXISTING TIMBER SUBSTRATES H74 H74/630 PLYWOOD UNDERLAY H74 H74/640 TIMBER FOR USE WITH ZINC WORK H74 H74/645 NEEDLE PUNCHED NONWOVEN POLYESTER GEOTEXTILE UNDERLAY H74 H74/650 LAYING UNDERLAY H74 H74/655 LAYING UNDERLAY H74 H74/710 FIXINGS FOR CLIPS H74 H74/715 ZINC CLIPS H74 H74/720 STANDING SEAM FIXED CLIPS H74 H74/725 STANDING SEAM SLIDING CLIPS H74 H74/730 ROLL CAP CLIPS H74 H74/735 ROLL CAPPING CLIPS H74 H74/745 CAPPED WELT CLIPS H74 H74/750 CLIPS FOR FLASHINGS/ CROSS JOINTS H74 H74/760 CONTINUOUS CLIPS H74 H74/770 WEDGE FIXING INTO JOINTS/ CHASES H74 H74/780 WEDGE FIXING INTO DAMP PROOF COURSE JOINTS H74 H74/790 SCREW FIXING INTO JOINTS/ CHASES H74 H74/810 FORMING DETAILS H74 H74/815 FREE EDGE DETAILS H74 H74/825 SOLDERING DETAILS H74 H74/830 STANDING SEAM JOINTS H74 H74/835 ANGLE STANDING SEAM JOINTS H74 H74/840 ROLL CAP JOINTS H74 H74/850 CAPPED WELT JOINTS H74 H74/860 DRIP/ STEP JOINTS H74 H74/880 SINGLE LOCK WELT JOINTS H74 H74/885 SINGLE LOCK WELT WITH CHECK WELT JOINTS H74 H74/890 DOUBLE LOCK WELT JOINTS H74 H75 STAINLESS STEEL STRIP/ SHEET COVERINGS/ FLASHINGS H H75/110 ROOFING H75 H75/130 CLADDING H75 H75/150 DORMERS H75 H75/210 GUTTER LINING WITH PROPRIETARY EXPANSION JOINTS H75 H75/220 GUTTER LINING WITH SADDLE EXPANSION JOINTS H75 H75/230 VALLEY GUTTER LINING TO SLATE/ TILE ROOFS H75 H75/240 RECESSED VALLEY GUTTER LINING H75 H75/245 VALLEY GUTTER LINING H75 H75/250 WEATHERING TO H75 H75/310 RIDGE/ HIP BATTEN ROLLS H75 H75/320 RIDGE/ HIP STANDING SEAMS H75 H75/330 STANDING SEAM EAVES WITH CLOSED ENDS H75 H75/340 STANDING SEAM EAVES WITH FOLDED DOWN ENDS H75 H75/350 BATTEN ROLL EAVES WITH SQUARED AND SOLDERED ENDS H75 H75/360 BATTEN ROLL EAVES WITH SPLAYED AND FOLDED ENDS H75 H75/370 STANDING SEAM VERGE H75 H75/380 BATTEN ROLL VERGE H75 H75/390 SET IN VERGE H75 H75/410 APRON FLASHINGS H75 H75/420 COVER FLASHINGS H75 H75/430 STEP FLASHINGS H75 H75/440 SOAKERS AND STEP FLASHINGS H75 H75/450 CHANGE OF ROOF PITCH FLASHINGS H75 H75/460 MISCELLANEOUS FLASHINGS H75 H75/510 WORKMANSHIP GENERALLY H75 H75/520 STAINLESS STEEL STRIP/ SHEET H75 H75/535 INTEGRITY OF STAINLESS STEEL H75 H75/537 INTEGRITY OF STAINLESS STEEL H75 H75/540 SOLDERING/ WELDING H75 H75/545 SOLDERING/ WELDING H75 H75/550 LIGHTNING PROTECTION H75 H75/555 LAYOUT H75 H75/560 CONTROL SAMPLES H75 H75/565 MOCK-UP H75 H75/570 EXISTING METAL RETAINED H75 H75/580 EXISTING METAL REUSED H75 H75/585 EXISTING METAL REMOVED TO REMAIN THE PROPERTY OF THE EMPLOYER H75 H75/610 SUITABILITY OF SUBSTRATES H75 H75/620 PREPARATION OF EXISTING TIMBER SUBSTRATES H75 H75/630 PLYWOOD UNDERLAY H75 H75/640 TIMBER FOR USE WITH STAINLESS STEEL WORK H75 H75/645 NEEDLE PUNCHED NONWOVEN POLYESTER GEOTEXTILE UNDERLAY H75 H75/650 LAYING UNDERLAY H75 H75/710 FIXINGS FOR CLIPS H75 H75/720 STANDING SEAM FIXED CLIPS H75 H75/725 STANDING SEAM SLIDING CLIPS H75 H75/730 BATTEN ROLL CLIPS H75 H75/735 BATTEN ROLL CAPPING CLIPS H75 H75/740 SLIDING COVER CLIPS H75 H75/750 CLIPS FOR FLASHINGS/ CROSS JOINTS H75 H75/760 CONTINUOUS CLIPS H75 H75/770 WEDGE FIXING INTO JOINTS/ CHASES H75 H75/780 WEDGE FIXING INTO DAMP PROOF COURSE JOINTS H75 H75/790 SCREW FIXING INTO JOINTS/ CHASES H75 H75/810 FORMING DETAILS H75 H75/815 FREE EDGE DETAILS H75 H75/820 SOLDERING DETAILS H75 H75/825 WELDING DETAILS H75 H75/830 STANDING SEAM JOINTS H75 H75/840 BATTEN ROLL JOINTS H75 H75/850 SLIDING COVER JOINTS H75 H75/860 DRIP/ STEP JOINTS H75 H75/870 LAPLOCK WELT JOINTS H75 H75/880 SINGLE LOCK WELT JOINTS H75 H75/890 DOUBLE LOCK WELT JOINTS H75 H90 TENSILE FABRIC COVERINGS H H90/10 INFORMATION TO BE PROVIDED WITH TENDER H90 H90/110 SINGLE LAYER FABRIC COVERING SYSTEM H90 H90/120 DOUBLE LAYER FABRIC COVERING SYSTEM H90 H90/130 MULTILAYER FABRIC COVERING SYSTEM H90 H90/140 INTERNAL SINGLE LAYER FABRIC SYSTEM H90 H90/151 CONTRACTOR'S DESIGN H90 H90/155 STRUCTURAL DESIGN PROVIDED H90 H90/160 EVIDENCE OF PERFORMANCE H90 H90/170 TESTING FABRIC MATERIAL H90 H90/210 PERFORMANCE H90 H90/220 VERIFICATION OF PERFORMANCE H90 H90/245 GLOBAL SAFETY FACTORS FOR FABRIC MEMBRANE H90 H90/250 FIRE RESISTANCE OF FABRIC COVERING H90 H90/255 INTERNAL SURFACE SPREAD OF FLAME OF FABRIC COVERING H90 H90/260 WATER PENETRATION H90 H90/270 HEAT CONSERVATION H90 H90/280 VAPOUR CONTROL: PARAMETERS PROVIDED H90 H90/285 VAPOUR CONTROL: CONTRACTOR DETERMINED PARAMETERS H90 H90/290 SOLAR AND LIGHT CONTROL H90 H90/310 PRODUCT SAMPLES H90 H90/315 FIXING SAMPLES H90 H90/320 CLAMPING PLATES H90 H90/330 STRAPS H90 H90/340 BELTS H90 H90/350 RODS H90 H90/355 BASE TENSIONING SYSTEM H90 H90/360 ROPES H90 H90/370 CORNER PLATES H90 H90/390 VAPOUR CONTROL LAYER H90 H90/400 THERMAL INSULATION H90 H90/410 INSULATION FIXINGS H90 H90/420 ROOFLIGHTS H90 H90/610 SETTING OUT OF FABRIC COVERINGS H90 H90/620 FABRICATING CABLE CUFFS H90 H90/630 FABRICATING PANELS H90 H90/640 FACTORY SEAMING OF PANELS H90 H90/650 LAYING VAPOUR CONTROL LAYER H90 H90/660 ATTACHING INSULATION H90 H90/710 ADVERSE WEATHER H90 H90/720 ATTACHING FABRIC MEMBRANE: CLAMPED AND BOLTED CONNECTION H90 H90/730 ATTACHING FABRIC MEMBRANE: TIED CONNECTION H90 H90/740 ATTACHING FABRIC MEMBRANE: PINNED CONNECTION H90 H90/750 ATTACHING FABRIC MEMBRANE H90 H90/910 INSPECTION H90 H90/920 TESTING OF FABRIC H90 H90/930 DOCUMENTATION H90 H90/940 COMPLETION H90 H92 RAINSCREEN CLADDING H H92/10 INFORMATION TO BE PROVIDED WITH TENDER H92 H92/110 RAINSCREEN CLADDING H92 H92/120 RAINSCREEN CLADDING H92 H92/130 MAJOR NONSTANDARD COMPONENTS H92 H92/210 DESIGN H92 H92/215 DESIGN PROPOSALS H92 H92/220 SPECIFICATION H92 H92/230 INFORMATION TO BE PROVIDED DURING DETAILED DESIGN H92 H92/232 QUALITY PLAN H92 H92/235 INFORMATION TO BE PROVIDED BEFORE COMMENCEMENT OF TESTING OR MANUFACTURE OF RAINSCREEN CLADDING SYSTEM H92 H92/240 PRODUCT SAMPLES H92 H92/250 SAMPLES OF FIXINGS H92 H92/260 FABRICATION SAMPLES H92 H92/270 MOCK-UP H92 H92/310 CWCT 'STANDARD FOR SYSTEMISED BUILDING ENVELOPES' H92 H92/342 CONTRACTOR'S DESIGN OF RAINSCREEN H92 H92/345 COMPLETION OF DESIGN OF RAINSCREEN H92 H92/347 STRUCTURAL DESIGN PROVIDED H92 H92/350 DEFLECTION UNDER WIND LOAD H92 H92/360 WIND RESISTANCE - CYCLIC LOADING H92 H92/370 APPEARANCE AND FIT H92 H92/380 GENERAL MOVEMENT H92 H92/385 THERMAL MOVEMENT - SERVICE TEMPERATURE RANGES H92 H92/390 AIR PERMEABILITY EXFILTRATION H92 H92/410 AIR PERMEABILITY H92 H92/420 WATER PENETRATION H92 H92/425 WIND LOAD SERVICEABILITY AND SAFETY OF RAINSCREEN PANELS - CYCLIC WIND LOADING H92 H92/430 THERMAL PROPERTIES H92 H92/440 AVOIDANCE OF CONDENSATION H92 H92/450 VAPOUR CONTROL LAYER H92 H92/460 SOUND TRANSMITTANCE H92 H92/480 FIRE RESISTANCE OF BACKING WALL TO BS 476- 21 H92 H92/485 INTERNAL SURFACE SPREAD OF FLAME OF BACKING WALL TO BS 476-7 H92 H92/490 CAVITY FIRE BARRIERS TO BS 476-20 H92 H92/495 DURABILITY H92 H92/497 LIGHTNING PROTECTION SYSTEM H92 H92/510 COMPARISON (TYPE) TESTING H92 H92/515 PROJECT TESTING (LABORATORY) H92 H92/520 PROJECT TESTING (SITE) H92 H92/530 TESTING AUTHORITY H92 H92/535 TESTING AUTHORITY H92 H92/540 LARGE TEST SPECIMEN H92 H92/550 SMALL TEST SPECIMEN H92 H92/560 TEST SEQUENCE - STANDARD LABORATORY TESTS H92 H92/570 TEST SEQUENCE - STANDARD LABORATORY AND DISCRETIONARY TESTS H92 H92/660 TEST H92 H92/665 WIND LOAD FATIGUE TEST, SMALL SPECIMEN H92 H92/670 TESTING OF FIXINGS H92 H92/672 SITE TESTING OF FIXINGS H92 H92/680 SITE SPRAY BAR TEST H92 H92/685 SITE HOSE TEST H92 H92/710 ALUMINIUM ALLOY FRAMING SECTIONS H92 H92/712 ALUMINIUM ALLOY SHEET H92 H92/715 CARBON STEEL FRAMING SECTIONS/ REINFORCEMENT H92 H92/717 CARBON STEEL SHEET H92 H92/720 STAINLESS STEEL SHEET H92 H92/725 TIMBER BATTENS H92 H92/730 MECHANICAL FIXINGS - MATERIAL REQUIREMENTS H92 H92/732 ADHESIVES H92 H92/735 FIXINGS AND FASTENERS H92 H92/740 GLASS GENERALLY H92 H92/742 HEAT SOAKED THERMALLY TOUGHENED GLASS H92 H92/745 INSULATING GLASS UNITS H92 H92/760 GASKETS H92 H92/765 WEATHERSTRIPPING OF OPENING UNITS H92 H92/770 GENERAL SEALANTS H92 H92/775 THERMAL INSULATION H92 H92/776 THERMAL INSULATION H92 H92/780 VAPOUR CONTROL LAYER H92 H92/785 BREATHER MEMBRANE H92 H92/810 PROTECTIVE COATING OF CARBON STEEL FRAMING SECTIONS/ REINFORCEMENT H92 H92/820 PROTECTIVE COATING OF CARBON STEEL MECHANICAL FIXINGS H92 H92/830 POWDER COATING H92 H92/840 ANODIZING H92 H92/850 POLYVINYLIDENE FLUORIDE (PVDF) COATING H92 H92/910 GENERALLY H92 H92/912 METALWORK H92 H92/915 TIMBER TREATMENT H92 H92/920 GLAZING H92 H92/922 FIXINGS/ ADHESIVES APPLICATION H92 H92/925 SEALANT APPLICATION H92 H92/930 ASSEMBLY H92 H92/960 PRELIMINARY RAINSCREEN CLADDING INSTALLATION H92 H92/970 RAINSCREEN CLADDING INSTALLATION H92 H92/975 WELDING H92 H92/980 INTERFACES H92 H92/985 DAMAGE H92 H92/995 MAINTENANCE H92 J WATERPROOFING J10 CEMENTITIOUS MORTAR TANKING/ DAMP PROOFING J J10/110 PROPRIETARY MORTAR J10 J10/120 CEMENT: SAND MORTAR WITH PROPRIETARY WATERPROOF ADMIXTURE J10 J10/130 PROPRIETARY CRYSTALLIZATION ACTIVE MORTAR J10 J10/310 CEMENTS FOR SITE BATCHED AND MIXED MORTAR J10 J10/315 SAND FOR SITE BATCHED AND MIXED MORTAR J10 J10/320 ADMIXTURES FOR SITE BATCHED AND MIXED MORTAR J10 J10/330 MOVEMENT JOINT SYSTEM J10 J10/340 SEALANTS J10 J10/350 MIXING J10 J10/360 COLD WEATHER J10 J10/410 SUITABILITY OF SUBSTRATES J10 J10/420 PREPARATION OF MORTAR JOINTS AND CAVITIES J10 J10/430 TANKING INTEGRITY J10 J10/510 APPLICATION GENERALLY J10 J10/520 JOINTS/ JUNCTIONS AND PENETRATIONS J10 J10/530 APPEARANCE OF TANKING J10 J10/540 FLATNESS/ SURFACE REGULARITY OF TANKING SCREEDS J10 J10/550 CURING AND DRYING J10 J10/560 PROTECTION J10 J20 MASTIC ASPHALT TANKING/ DAMP PROOFING J J20/110 TANKING J20 J20/130 TANK LINING J20 J20/150 DAMP PROOFING OF FLOORS J20 J20/210 SUITABILITY OF SUBSTRATES J20 J20/220 GROUND WATER LEVEL J20 J20/240 SEPARATING MEMBRANE J20 J20/245 SEPARATING MEMBRANE - NOTICE OF REQUIREMENT J20 J20/250 KEYING TO EXISTING VERTICAL/ SLOPING CONCRETE J20 J20/255 KEYING TO EXISTING VERTICAL/ SLOPING LIGHTWEIGHT CONCRETE J20 J20/260 KEYING TO EXISTING BRICKWORK/ BLOCKWORK J20 J20/270 KEYING TO SMOOTH FACED BRICKWORK/ BLOCKWORK J20 J20/310 MASTIC ASPHALT BLOCKS J20 J20/315 LAYING MASTIC ASPHALT J20 J20/320 SERVICE PIPES/ PIPE DUCTS PENETRATIONS J20 J20/350 PROTECTION OF TANKING J20 J20/360 PROTECTION OF DAMP PROOFING J20 J20/370 BACKFILLING J20 J21 MASTIC ASPHALT ROOFING/ INSULATION/ FINISHES J J21/110 WARM DECK ROOF COATING J21 J21/115 WARM DECK ROOF COATING J21 J21/120 INVERTED ROOF COATING J21 J21/125 INVERTED ROOF COATING J21 J21/130 COLD DECK ROOF COATING J21 J21/135 COLD DECK ROOF COATING J21 J21/150 WATERPROOF PAVING J21 J21/155 WATERPROOF PAVING J21 J21/160 PAVING J21 J21/165 PAVING J21 J21/180 SKIRTINGS/ VERTICAL WORK J21 J21/185 SKIRTINGS/ VERTICAL WORK J21 J21/202 CONTRACTOR'S DESIGN OF ROOF COVERINGS J21 J21/205 COMPLETION OF DESIGN OF ROOF COVERINGS J21 J21/207 ROOF COVERING DESIGN PROVIDED J21 J21/210 ROOF PERFORMANCE J21 J21/220 AVOIDANCE OF INTERSTITIAL CONDENSATION: WARM AND INVERTED ROOFS J21 J21/225 AVOIDANCE OF INTERSTITIAL CONDENSATION: WARM AND INVERTED ROOFS J21 J21/230 INSULATION J21 J21/320 PRIMER J21 J21/325 BONDING COMPOUND J21 J21/330 TIMBER TRIMS, ETC J21 J21/340 PREFORMED SLEEVES, TRIMS, ETC J21 J21/345 PERIMETER TRIMS J21 J21/360 PLYWOOD OVERLAY TO METAL DECK J21 J21/365 ORIENTED STRAND BOARD OVERLAY TO METAL DECK J21 J21/367 OVERLAY TO METAL DECK J21 J21/370 COVER STRIPS TO JOINTS IN RIGID BOARD SUBSTRATES J21 J21/375 MOVEMENT JOINTS J21 J21/380 PROPRIETARY MOVEMENT JOINTS J21 J21/395 VAPOUR CONTROL LAYER J21 J21/400 SEPARATING LAYER (LOOSE LAID) J21 J21/402 MASTIC ASPHALT (ROOFING) J21 J21/404 MASTIC ASPHALT (PAVING) J21 J21/410 EXPANDED POLYSTYRENE (EPS) WARM DECK ROOF INSULATION J21 J21/420 RIGID URETHANE FOAM WARM DECK ROOF INSULATION J21 J21/425 MINERAL WOOL (MW) WARM DECK ROOF INSULATION J21 J21/430 WARM DECK ROOF INSULATION J21 J21/440 INVERTED ROOF INSULATION J21 J21/450 OVERLAY TO WARM DECK ROOF INSULATION J21 J21/455 SAND FOR RUBBING J21 J21/460 STONE BALLAST J21 J21/465 PRECAST CONCRETE PAVING SLABS J21 J21/467 SUPPORT SYSTEM FOR PRECAST CONCRETE PAVING SLABS J21 J21/470 PAVING TILES J21 J21/475 CHIPPINGS AND DRESSING COMPOUND J21 J21/485 ROOF VENTILATORS J21 J21/490 MINERAL/ METAL FACED CAP SHEET J21 J21/495 SOLAR REFLECTIVE PAINT J21 J21/510 ADVERSE WEATHER J21 J21/520 INCOMPLETE WORK J21 J21/525 PREPARING EDGES OF EXISTING MASTIC ASPHALT J21 J21/530 APPLYING PRIMERS J21 J21/540 APPLYING BONDING COMPOUNDS J21 J21/550 CONTROL SAMPLES J21 J21/610 SUITABILITY OF SUBSTRATES J21 J21/620 REMOVING EXISTING MASTIC ASPHALT J21 J21/630 MAKING GOOD EXISTING MASTIC ASPHALT J21 J21/635 REMOVING EXISTING CHIPPINGS J21 J21/640 FIXING TIMBER TRIMS J21 J21/642 KEYING TO VERTICAL/ SLOPING DENSE CONCRETE J21 J21/644 KEYING TO NEW BRICKWORK/ DENSE BLOCKWORK J21 J21/646 KEYING TO EXISTING BRICKWORK/ DENSE BLOCKWORK J21 J21/648 KEYING TO METAL SURFACES J21 J21/649 APPLYING METAL LATHING TO VERTICAL/ SLOPING J21 J21/650 LAYING OVERLAYS TO METAL DECK J21 J21/660 JOINTS IN RIGID BOARD SUBSTRATES J21 J21/670 LAYING VAPOUR CONTROL LAYER J21 J21/680 LAYING WARM DECK ROOF INSULATION J21 J21/685 LAYING OVERLAY TO WARM DECK ROOF INSULATION J21 J21/690 MARGIN INFILL TO ANGLE FILLETS IN WARM DECK ROOF J21 J21/695 SEPARATING LAYER J21 J21/710 DELIVERY J21 J21/720 DELIVERY J21 J21/730 TRANSPORTING J21 J21/735 LOCALIZED HEATING J21 J21/740 LAYING MASTIC ASPHALT J21 J21/750 MASTIC ASPHALT SKIRTINGS AND VERTICAL WORK J21 J21/760 MARGIN INFILL TO MASTIC ASPHALT PAVINGS J21 J21/770 INSTALLING MOVEMENT JOINTS J21 J21/775 INSTALLING PROPRIETARY MOVEMENT JOINTS J21 J21/785 FIXING PERIMETER TRIMS J21 J21/790 INSTALLING ROOF VENTILATORS J21 J21/810 LAYING INVERTED ROOF INSULATION J21 J21/820 LAYING STONE BALLAST J21 J21/840 LAYING PRECAST CONCRETE PAVING SLABS J21 J21/860 LAYING PAVING TILES J21 J21/870 LAYING CHIPPINGS J21 J21/872 LAYING COATED CHIPPINGS J21 J21/874 LAYING MINERAL/ METAL FACED CAP SHEETS J21 J21/876 CRIMPING J21 J21/880 APPLYING SOLAR REFLECTIVE PAINTS J21 J21/910 INSPECTION J21 J21/920 ELECTRONIC ROOF INTEGRITY TEST J21 J21/930 FLOOD TEST J21 J21/940 COMPLETION J21 J30 LIQUID APPLIED TANKING/ DAMP PROOFING J J30/10 COLD APPLIED DAMP PROOFING J30 J30/110 COLD APPLIED TANKING J30 J30/130 COLD APPLIED DAMP PROOFING J30 J30/150 HOT APPLIED DAMP PROOFING J30 J30/155 HOT APPLIED DAMP PROOFING J30 J30/20 HOT APPLIED DAMP PROOFING J30 J30/205 SUITABILITY OF SUBSTRATE J30 J30/206 ADHESION TESTING J30 J30/207 PRIMERS J30 J30/210 COATING APPLICATION J30 J30/220 COLD APPLIED COATINGS J30 J30/230 BITUMINOUS COATINGS J30 J30/235 MODIFIED COATINGS J30 J30/240 REINFORCEMENT J30 J30/250 HOT APPLIED COATINGS J30 J30/260 JUNCTIONS WITH DPCS J30 J30/270 BLINDING J30 J30/310 INSPECTION J30 J30/320 ELECTRONIC INTEGRITY TEST J30 J30/330 PROTECTION OF EXTERNAL COATINGS J30 J30/340 BACKFILLING TO EXTERNAL COATINGS J30 J30/50 WORKMANSHIP J30 J30/60 JUNCTIONS WITH DPCS J30 J30/70 BLINDING J30 J30/80 PROTECTION OF COATINGS J30 J30/90 BACKFILLING TO EXTERNAL COATINGS J30 J31 LIQUID APPLIED WATERPROOF ROOF COATINGS J J31/110 COLD DECK ROOF COATING J31 J31/120 WARM DECK ROOF COATING J31 J31/130 INVERTED ROOF COATING J31 J31/202 CONTRACTOR'S DESIGN OF ROOFING J31 J31/205 COMPLETION OF ROOFING DESIGN J31 J31/207 ROOFING DESIGN PROVIDED J31 J31/210 ROOF PERFORMANCE J31 J31/220 AVOIDANCE OF INTERSTITIAL CONDENSATION IN WARM AND INVERTED ROOFS J31 J31/225 AVOIDANCE OF INTERSTITIAL CONDENSATION IN WARM AND INVERTED ROOFS J31 J31/230 INSULATION J31 J31/315 TIMBER TRIMS J31 J31/320 PLYWOOD OVERLAY TO METAL DECK J31 J31/325 ORIENTED STRAND BOARD (OSB) OVERLAY TO METAL DECK J31 J31/330 VAPOUR CONTROL LAYER J31 J31/331 EXPANDED POLYSTYRENE (EPS) WARM DECK ROOF INSULATION J31 J31/332 EXTRUDED POLYSTYRENE (XPS) WARM DECK ROOF INSULATION J31 J31/333 RIGID URETHANE FOAM WARM DECK ROOF INSULATION J31 J31/334 MINERAL WOOL WARM DECK ROOF INSULATION J31 J31/335 WARM DECK ROOF INSULATION J31 J31/340 INVERTED ROOF INSULATION J31 J31/345 BITUMEN IMPREGNATED SOFTBOARD OVERLAY TO WARM DECK ROOF INSULATION J31 J31/350 CORKBOARD OVERLAY TO WARM DECK ROOF INSULATION J31 J31/352 CARRIER MEMBRANE J31 J31/353 WATERPROOF COATING J31 J31/355 PERIMETER TRIMS J31 J31/357 PIPE COLLARS J31 J31/360 ROOF VENTILATORS J31 J31/365 STONE BALLAST J31 J31/370 PRECAST CONCRETE PAVING SLABS J31 J31/375 PAVING TILES J31 J31/380 UV RESISTANT SEALER J31 J31/385 WALKWAY PROTECTIVE COATING J31 J31/410 ADVERSE WEATHER J31 J31/420 SUITABILITY OF SUBSTRATE J31 J31/510 REMOVING EXISTING COVERINGS J31 J31/515 EXISTING FLASHINGS J31 J31/520 PRELIMINARY POWER WASH TO EXISTING COVERINGS J31 J31/525 RENEWING EXISTING SUBSTRATES/ COVERINGS J31 J31/530 MAKING GOOD EXISTING LIQUID APPLIED WATERPROOF ROOF COATINGS J31 J31/535 MAKING GOOD EXISTING REINFORCED BITUMEN MEMBRANE COVERING J31 J31/540 MAKING GOOD EXISTING MASTIC ASPHALT COVERING J31 J31/545 MAKING GOOD EXISTING FIBRE CEMENT SHEET COVERING J31 J31/550 MAKING GOOD EXISTING METAL SHEET COVERING J31 J31/555 MAKING GOOD EXISTING CEMENTITIOUS SLABS/ SCREEDS J31 J31/560 EXISTING EDGE TRIMS J31 J31/565 EXISTING GUTTERS/ OUTLETS J31 J31/570 EXISTING CRACKS/ GAPS J31 J31/575 FINAL POWER WASH TO EXISTING COVERINGS J31 J31/580 STERILIZATION TREATMENT TO EXISTING COVERINGS J31 J31/610 FIXING TIMBER TRIMS J31 J31/620 LAYING OVERLAY TO METAL DECK J31 J31/630 LAYING VAPOUR CONTROL LAYER J31 J31/640 LAYING WARM DECK ROOF INSULATION J31 J31/650 LAYING OVERLAY TO WARM DECK ROOF INSULATION J31 J31/660 FIXING PERIMETER TRIMS J31 J31/670 INSTALLING ROOF VENTILATORS J31 J31/710 ADHESION TESTS J31 J31/720 APPLYING PRIMERS/ CONDITIONERS J31 J31/730 LAYING CARRIER MEMBRANE J31 J31/740 MOVEMENT JOINTS IN SUBSTRATE J31 J31/750 PRELIMINARY LOCAL REINFORCEMENT J31 J31/760 APPLICATION OF ROOF COATINGS J31 J31/770 SKIRTINGS AND UPSTANDS J31 J31/810 BLINDING J31 J31/830 INSTALLING INVERTED ROOF INSULATION J31 J31/840 LAYING STONE BALLAST J31 J31/850 LAYING PRECAST CONCRETE PAVING SLABS J31 J31/860 LAYING PAVING TILES J31 J31/880 APPLYING UV RESISTANT SEALER J31 J31/890 APPLYING WALKWAY PROTECTIVE COATING J31 J31/910 INSPECTION J31 J31/920 ELECTRONIC ROOF INTEGRITY TEST J31 J31/930 FLOOD TEST J31 J31/940 COMPLETION J31 J40 FLEXIBLE SHEET WATERPROOFING/ DAMP PROOFING J J40/10 SOFT BLINDING TO HARDCORE BEDS J40 J40/110 SOFT BLINDING TO HARDCORE BEDS J40 J40/115 CONCRETE BLINDING TO HARDCORE BEDS J40 J40/120 LOOSE LAID POLYETHYLENE DAMP PROOFING J40 J40/130 LOOSE LAID POLYETHYLENE OVERSITE DAMP PROOFING J40 J40/135 LOOSE LAID OVERSITE DAMP PROOFING J40 J40/140 LOOSE LAID POLYETHYLENE GAS RETARDANT DAMP PROOFING J40 J40/143 LOOSE LAID GAS RETARDANT DAMP PROOFING J40 J40/145 LOOSE LAID WELDABLE POLYETHYLENE GAS RETARDANT DAMP PROOFING J40 J40/146 LOOSE LAID WELDABLE POLYETHYLENE GAS RETARDANT DAMP PROOFING WITH ANCHORS J40 J40/15 CONCRETE BLINDING TO HARDCORE BEDS J40 J40/150 LOOSE LAID BITUMEN DAMP PROOFING J40 J40/160 LOOSE LAID BITUMEN DAMP PROOFING J40 J40/170 LOOSE LAID BITUMEN GAS RETARDANT DAMP PROOFING J40 J40/180 SELF-ADHESIVE BITUMEN GAS RETARDANT DAMP PROOFING/ TANKING J40 J40/190 SELF-ADHESIVE BITUMEN DAMP PROOFING/ TANKING J40 J40/20 LOOSE LAID POLYETHYLENE DAMP PROOFING J40 J40/210 FULLY BONDED BITUMEN DAMP PROOFING J40 J40/220 FULLY BONDED BITUMEN DAMP PROOFING J40 J40/230 FULLY BONDED BITUMEN DAMP PROOFING J40 J40/250 FULLY BONDED BITUMEN TANKING J40 J40/251 FULLY BONDED BITUMEN TANKING J40 J40/260 FULLY BONDED BITUMEN DAMP PROOFING/ TANKING J40 J40/270 FULLY BONDED BITUMEN DAMP PROOFING/ TANKING J40 J40/280 FULLY BONDED BITUMEN GAS RETARDANT DAMP PROOFING/ TANKING J40 J40/285 LOOSE LAID BENTONITE DAMP PROOFING/ TANKING J40 J40/290 HIGH DENSITY POLYETHYLENE/ POLYPROPYLENE STUDDED CAVITY DRAIN MEMBRANE J40 J40/295 GEOCOMPOSITE STUDDED CAVITY DRAINAGE/ VENTING MEMBRANE J40 J40/297 WATERPROOFING/ DAMP PROOFING MEMBRANE J40 J40/30 LOOSE LAID POLYETHYLENE OVERSITE DAMP PROOFING J40 J40/310 WORKMANSHIP GENERALLY J40 J40/320 INSPECTION J40 J40/335 PRIMERS J40 J40/340 HOT APPLIED BONDING COMPOUNDS J40 J40/345 COLD APPLIED BONDING COMPOUNDS J40 J40/35 LOOSE LAID POLYETHYLENE GAS RETARDANT DAMP PROOFING J40 J40/350 ANGLES IN BONDED DAMP PROOFING/ TANKING J40 J40/360 JUNCTIONS WITH PROJECTING DPCS/ CAVITY TRAYS J40 J40/365 JUNCTIONS WITH FLUSH DPCS/ CAVITY TRAYS J40 J40/370 PREFORMED COLLARS FOR PIPES, DUCTS, CABLES, ETC. J40 J40/380 PROTECTION BOARDS FOR DAMP PROOFING/ TANKING J40 J40/382 CAVITY DRAINAGE CHANNELS J40 J40/384 CAVITY DRAINAGE PUMPS J40 J40/386 CAVITY DRAINAGE SUMPS J40 J40/388 CAVITY DRAINAGE SUMPS WITH INTEGRAL PUMPS J40 J40/40 SELF-ADHESIVE BITUMEN DAMP PROOFING J40 J40/45 SELF-ADHESIVE BITUMEN GAS RETARDANT DAMP PROOFING/ TANKING J40 J40/47 HIGH DENSITY POLYETHYLENE/ POLYPROPYLENE STUDDED CAVITY DRAIN MEMBRANE J40 J40/50 WORKMANSHIP GENERALLY J40 J40/55 ANGLES IN SELF-ADHESIVE DAMP PROOFING/ TANKING J40 J40/60 JUNCTIONS WITH PROJECTING DPCS/ CAVITY TRAYS J40 J40/65 JUNCTIONS WITH FLUSH DPCS/ CAVITY TRAYS J40 J40/70 PROTECTION BOARDS FOR DAMP PROOFING/ TANKING J40 J41 REINFORCED BITUMEN MEMBRANE ROOF COVERINGS J J41/110 BUILT-UP REINFORCED BITUMEN MEMBRANE WARM DECK ROOF COVERING J41 J41/115 SINGLE LAYER REINFORCED BITUMEN MEMBRANE WARM DECK ROOF COVERING J41 J41/120 BUILT-UP REINFORCED BITUMEN MEMBRANE INVERTED ROOF COVERING J41 J41/125 SINGLE LAYER REINFORCED BITUMEN MEMBRANE INVERTED ROOF COVERING J41 J41/130 BUILT-UP REINFORCED BITUMEN MEMBRANE COLD DECK ROOF COVERING J41 J41/135 SINGLE LAYER REINFORCED BITUMEN MEMBRANE COLD DECK ROOF COVERING J41 J41/202 CONTRACTOR'S DESIGN OF ROOF COVERINGS J41 J41/205 COMPLETION OF DESIGN OF ROOF COVERINGS J41 J41/207 ROOF COVERING DESIGN PROVIDED J41 J41/210 ROOF PERFORMANCE J41 J41/220 AVOIDANCE OF INTERSTITIAL CONDENSATION: WARM AND INVERTED ROOFS J41 J41/225 AVOIDANCE OF INTERSTITIAL CONDENSATION: WARM AND INVERTED ROOFS J41 J41/230 INSULATION J41 J41/320 PRIMER J41 J41/322 PRIMER J41 J41/325 BONDING COMPOUND J41 J41/327 BONDING COMPOUND J41 J41/330 TIMBER TRIMS, ETC J41 J41/335 ANGLE FILLETS J41 J41/340 PREFORMED SLEEVES J41 J41/345 PERIMETER TRIMS J41 J41/350 MECHANICAL FASTENERS FOR SINGLE LAYER REINFORCED BITUMEN MEMBRANES J41 J41/355 NAILS FOR FIXING REINFORCED BITUMEN MEMBRANES J41 J41/360 PLYWOOD OVERLAY TO METAL DECK J41 J41/365 ORIENTED STRAND BOARD (OSB) OVERLAY TO METAL DECK J41 J41/370 COVER STRIPS TO JOINTS IN RIGID BOARD SUBSTRATES J41 J41/375 MINOR MOVEMENT JOINTS IN SUBSTRATES J41 J41/385 FILTER LAYER J41 J41/395 VAPOUR CONTROL LAYER J41 J41/400 BUILT-UP REINFORCED BITUMEN WATERPROOF COVERING J41 J41/405 SINGLE LAYER REINFORCED BITUMEN WATERPROOF COVERING J41 J41/410 EXPANDED POLYSTYRENE (EPS) WARM DECK ROOF INSULATION J41 J41/420 RIGID URETHANE FOAM WARM DECK ROOF INSULATION J41 J41/425 MINERAL WOOL (MW) WARM DECK ROOF INSULATION J41 J41/430 WARM DECK ROOF INSULATION J41 J41/440 INVERTED ROOF INSULATION J41 J41/450 BITUMEN IMPREGNATED SOFTBOARD OVERLAY TO WARM DECK ROOF INSULATION J41 J41/455 CORKBOARD OVERLAY TO WARM DECK ROOF INSULATION J41 J41/460 STONE BALLAST J41 J41/465 PRECAST CONCRETE PAVING SLABS J41 J41/467 SUPPORT SYSTEM FOR PRECAST CONCRETE PAVING SLABS J41 J41/470 PAVING TILES J41 J41/475 CHIPPINGS AND DRESSING COMPOUND J41 J41/478 SOLAR REFLECTIVE PAINT J41 J41/480 PIPE COLLARS J41 J41/485 ROOF VENTILATORS J41 J41/515 ADVERSE WEATHER J41 J41/520 INCOMPLETE WORK J41 J41/530 APPLYING PRIMERS J41 J41/540 APPLYING BONDING COMPOUNDS J41 J41/550 CONTROL SAMPLES J41 J41/610 SUITABILITY OF SUBSTRATES J41 J41/620 RENEWING EXISTING COVERINGS J41 J41/625 REMOVING EXISTING COVERINGS J41 J41/630 MAKING GOOD EXISTING REINFORCED BITUMEN MEMBRANE ROOF COVERING J41 J41/640 FIXING TIMBER TRIMS J41 J41/650 LAYING OVERLAY TO METAL DECK J41 J41/660 JOINTS IN RIGID BOARD SUBSTRATES J41 J41/670 LAYING VAPOUR CONTROL LAYER J41 J41/680 LAYING WARM DECK ROOF INSULATION J41 J41/690 LAYING OVERLAY TO WARM DECK ROOF INSULATION J41 J41/710 LAYING REINFORCED BITUMEN MEMBRANES GENERALLY J41 J41/715 LAYING REINFORCED BITUMEN MEMBRANES ON ROOFS PITCHED MORE THAN 5° J41 J41/720 NAILING FIRST LAYER OF REINFORCED BITUMEN MEMBRANE TO TIMBER SUBSTRATE J41 J41/730 PARTIAL BONDING OF REINFORCED BITUMEN MEMBRANE J41 J41/735 POUR AND ROLL BONDING OF REINFORCED BITUMEN MEMBRANES J41 J41/740 TORCH-ON BONDING OF REINFORCED BITUMEN MEMBRANE J41 J41/745 COLD APPLIED ADHESIVE BONDING OF REINFORCED BITUMEN MEMBRANES J41 J41/747 SELF-ADHESIVE BONDING OF REINFORCED BITUMEN MEMBRANES J41 J41/750 LAYING MINERAL FACED REINFORCED BITUMEN MEMBRANES J41 J41/755 LAYING METAL FACED REINFORCED BITUMEN MEMBRANES J41 J41/760 MECHANICAL FIXING OF SINGLE LAYER REINFORCED BITUMEN MEMBRANES J41 J41/765 WELDED JOINTING OF SINGLE LAYER REINFORCED BITUMEN MEMBRANES J41 J41/775 SKIRTINGS AND UPSTANDS J41 J41/780 WELTED DRIPS J41 J41/785 FIXING PERIMETER TRIMS J41 J41/790 INSTALLING ROOF VENTILATORS J41 J41/810 LAYING INVERTED ROOF INSULATION J41 J41/820 LAYING STONE BALLAST J41 J41/840 LAYING PRECAST CONCRETE PAVING SLABS J41 J41/860 LAYING PAVING TILES J41 J41/870 APPLYING CHIPPINGS J41 J41/874 APPLYING SOLAR REFLECTIVE PAINTS J41 J41/910 INSPECTION J41 J41/920 ELECTRONIC ROOF INTEGRITY TEST J41 J41/930 FLOOD TEST J41 J41/940 COMPLETION J41 J42 SINGLE LAYER POLYMERIC SHEET ROOF COVERINGS J J42/110 WARM DECK ROOF COVERING J42 J42/120 INVERTED ROOF COVERING J42 J42/130 COLD DECK ROOF COVERING J42 J42/202 CONTRACTOR'S DESIGN OF ROOF COVERINGS J42 J42/205 COMPLETION OF DESIGN OF ROOF COVERINGS J42 J42/207 ROOF COVERING DESIGN PROVIDED J42 J42/210 ROOF PERFORMANCE J42 J42/220 AVOIDANCE OF INTERSTITIAL CONDENSATION: WARM AND INVERTED ROOFS J42 J42/225 AVOIDANCE OF INTERSTITIAL CONDENSATION: WARM AND INVERTED ROOFS J42 J42/230 INSULATION J42 J42/320 PRIMER J42 J42/325 ADHESIVE J42 J42/330 TIMBER TRIMS, ETC J42 J42/340 PREFORMED SLEEVES J42 J42/345 PERIMETER TRIMS J42 J42/355 MECHANICAL FASTENERS, WASHERS, PRESSURE PLATES, ETC J42 J42/360 PLYWOOD OVERLAY TO METAL DECK J42 J42/365 ORIENTED STRAND BOARD (OSB) OVERLAY TO METAL DECK J42 J42/370 COVER STRIPS TO JOINTS IN RIGID BOARD SUBSTRATES J42 J42/375 MINOR MOVEMENT JOINTS IN SUBSTRATES J42 J42/380 PROTECTION LAYER J42 J42/383 SEPARATING LAYER J42 J42/385 FILTER LAYER J42 J42/395 VAPOUR CONTROL LAYER J42 J42/400 WATERPROOF MEMBRANE J42 J42/410 EXPANDED POLYSTYRENE (EPS) WARM DECK ROOF INSULATION J42 J42/415 EXTRUDED POLYSTYRENE (XPS) WARM DECK ROOF INSULATION J42 J42/420 RIGID URETHANE FOAM WARM DECK ROOF INSULATION J42 J42/425 MINERAL WOOL (MW) WARM DECK ROOF INSULATION J42 J42/427 PHENOLIC FOAM (PF) WARM DECK ROOF INSULATION J42 J42/430 WARM DECK ROOF INSULATION J42 J42/440 INVERTED ROOF INSULATION J42 J42/450 STANDING SEAM PROFILES J42 J42/460 STONE BALLAST J42 J42/465 PRECAST CONCRETE PAVING SLABS J42 J42/467 SUPPORT SYSTEM FOR PRECAST CONCRETE PAVING SLABS J42 J42/480 PIPE COLLARS J42 J42/485 MEMBRANE WALKWAY J42 J42/490 ROOF VENTILATORS J42 J42/510 ADVERSE WEATHER J42 J42/520 INCOMPLETE WORK J42 J42/530 APPLYING PRIMERS J42 J42/550 CONTROL SAMPLES J42 J42/610 SUITABILITY OF SUBSTRATES J42 J42/620 RENEWING EXISTING COVERINGS J42 J42/625 REMOVING EXISTING COVERINGS J42 J42/640 FIXING TIMBER TRIMS J42 J42/650 LAYING METAL DECK OVERLAY J42 J42/660 JOINTS IN RIGID BOARD SUBSTRATES J42 J42/670 LAYING VAPOUR CONTROL LAYER J42 J42/680 LAYING WARM DECK ROOF INSULATION J42 J42/710 MECHANICAL FIXING OF WATERPROOF MEMBRANE J42 J42/720 ADHESIVE BONDING OF WATERPROOF MEMBRANE J42 J42/730 WELDED JOINTING OF WATERPROOF MEMBRANE J42 J42/740 ADHESIVE JOINTING OF WATERPROOF MEMBRANE J42 J42/750 TAPE JOINTING OF WATERPROOF MEMBRANE J42 J42/760 PERIMETER OF MEMBRANE J42 J42/765 PERIMETER DETAILS FOR THERMOPLASTIC MEMBRANES J42 J42/770 PERIMETER DETAILS FOR THERMOPLASTIC MEMBRANES J42 J42/775 PERIMETER DETAILS FOR ELASTOMERIC MEMBRANES J42 J42/780 ROOF PENETRATIONS THROUGH THERMOPLASTIC MEMBRANES J42 J42/785 ROOF PENETRATIONS THROUGH ELASTOMERIC MEMBRANES J42 J42/790 ATTACHMENT OF STANDING SEAM PROFILES J42 J42/795 INSTALLING ROOF VENTILATORS J42 J42/810 LAYING INVERTED ROOF INSULATION J42 J42/820 LAYING STONE BALLAST J42 J42/830 BONDING STONE BALLAST J42 J42/840 LAYING PRECAST CONCRETE PAVING SLABS J42 J42/850 LAYING MEMBRANE WALKWAYS J42 J42/910 INSPECTION J42 J42/920 ELECTRONIC ROOF INTEGRITY TEST J42 J42/930 FLOOD TEST J42 J42/935 COMMISSIONING AND TESTING OF PHOTOVOLTAIC ROOF MEMBRANE J42 J42/940 COMPLETION J42 J44 SHEET LININGS FOR POOLS/LAKES/WATERWAYS J J44/110 GEOMEMBRANE LINING J44 J44/115 GEOMEMBRANE LINING J44 J44/120 GEOSYNTHETIC CLAY LINING (GCL) J44 J44/210 SUITABILITY OF SUBSTRATE J44 J44/215 SUITABILITY OF SUBSTRATE J44 J44/220 QUALITY CONTROL J44 J44/225 COMPETENCE J44 J44/230 GEOTEXTILE SUBSTRATE LINING J44 J44/240 INSTALLATION OF GEOMEMBRANE LINING J44 J44/250 INSTALLATION OF GCL J44 J44/260 ANCHOR TRENCH J44 J44/270 JOINT TESTING J44 J44/280 GEOTEXTILE PROTECTIVE LINING J44 J44/290 PROTECTIVE LAYER J44 J44/300 FILLING WITH WATER J44 J44/305 FILLING WITH WATER J44 K LININGS/ SHEATHING/ DRY PARTITIONING K10 PLASTERBOARD DRY LININGS/ PARTITIONS/ CEILINGS K K10/115 METAL STUD PARTITION SYSTEM K10 K10/125 METAL STUD PARTITION SYSTEM K10 K10/145 WALL LINING SYSTEM (METAL STUDS) K10 K10/155 WALL LINING SYSTEM (METAL STUDS) K10 K10/165 WALL LINING SYSTEM (METAL FRAMING) K10 K10/175 WALL LINING SYSTEM (METAL FURRINGS) K10 K10/185 WALL LINING SYSTEM (ADHESIVE) K10 K10/205 LINING ON TIMBER K10 K10/215 SUSPENDED CEILING SYSTEM K10 K10/220 PROPRIETARY SUSPENDED CEILING SYSTEM K10 K10/245 CEILING LINING ON TIMBER K10 K10/255 ENCASEMENT SYSTEM (METAL FRAMING) K10 K10/265 ENCASEMENT SYSTEM (FRAMELESS) K10 K10/275 ENCASEMENT ON TIMBER FRAMING K10 K10/305 COMPLIANCE WITH PERFORMANCE REQUIREMENTS K10 K10/325 PREPARATION OF MASONRY TO RECEIVE WALL LININGS K10 K10/335 ADDITIONAL SUPPORTS K10 K10/375 NEW WET LAID BASES K10 K10/395 CONTROL SAMPLES K10 K10/401 GYPSUM PLASTERBOARD K10 K10/402 GYPSUM PLASTERBOARD (VAPOUR CONTROL) K10 K10/403 GYPSUM PLASTERBOARD (MOISTURE RESISTANT) K10 K10/404 GYPSUM PLASTERBOARD (IMPROVED FIRE PROTECTION) K10 K10/406 GYPSUM PLASTERBOARD (IMPROVED FIRE PROTECTION AND MOISTURE RESISTANT) K10 K10/407 GYPSUM PLASTERBOARD (IMPROVED FIRE PROTECTION AND VAPOUR CONTROL) K10 K10/408 GYPSUM PLASTERBOARD (IMPACT RESISTANT) K10 K10/409 GYPSUM PLASTERBOARD (IMPROVED SOUND INSULATION) K10 K10/410 GYPSUM PLASTERBOARD (IMPROVED SOUND INSULATION AND MOISTURE RESISTANT) K10 K10/415 GYPSUM PLASTERBOARD K10 K10/430 ACCESS PANELS K10 K10/432 METAL STUDS K10 K10/435 DRY LININGS GENERALLY K10 K10/445 CEILINGS K10 K10/455 METAL FRAMING FOR PARTITIONS/ WALL LININGS K10 K10/465 STAGGERED STUD PARTITIONS K10 K10/475 METAL FURRINGS FOR WALL LININGS K10 K10/485 SUSPENDED CEILING GRIDS K10 K10/505 INSTALLING MINERAL WOOL INSULATION K10 K10/510 SEALING GAPS AND AIR PATHS K10 K10/530 CAVITY FIRE BARRIERS WITHIN PARTITIONS/ WALL LININGS K10 K10/545 CAVITY FIRE BARRIERS WITHIN SUSPENDED CEILINGS K10 K10/555 FIRE STOPPING AT PERIMETERS OF DRY LINING SYSTEMS K10 K10/560 JOINTS BETWEEN BOARDS K10 K10/565 VERTICAL JOINTS K10 K10/570 HORIZONTAL JOINTS K10 K10/575 PLANK PLASTERBOARD K10 K10/580 INSULATION BACKED PLASTERBOARD K10 K10/590 FIXING PLASTERBOARD TO METAL FRAMING/ FURRINGS K10 K10/592 FIXING INSULATION BACKED PLASTERBOARD TO METAL FURRINGS K10 K10/595 DEFLECTION HEADS K10 K10/610 FIXING PLASTERBOARD TO TIMBER K10 K10/620 FIXING PLASTERBOARD WITH ADHESIVE DABS K10 K10/625 FIXING INSULATION BACKED PLASTERBOARD WITH ADHESIVE DABS K10 K10/630 FIXING INSULATION BACKED PLASTERBOARD WITH ADHESIVE SPOTS K10 K10/650 LEVEL OF DRY LINING ACROSS JOINTS K10 K10/670 SEAMLESS JOINTING TO PLASTERBOARDS K10 K10/680 SKIM COAT PLASTER FINISH K10 K10/692 RIGID BEADS/STOPS K10 K10/695 INSTALLING BEADS/ STOPS K10 K10/725 REPAIRS TO EXISTING PLASTERBOARD K10 K11 RIGID SHEET FLOORING/ SHEATHING/ DECKING/ SARKING/ LININGS/ CASINGS K K11/110 WOOD-BASED SHEETS GENERALLY K11 K11/115 BATTENED PLYWOOD FLOATING FLOOR K11 K11/125 BATTENED PARTICLEBOARD FLOATING FLOOR K11 K11/135 BATTENED ORIENTED STRAND BOARD FLOATING FLOOR K11 K11/145 BATTENED CEMENT BONDED PARTICLEBOARD FLOATING FLOOR K11 K11/215 PLYWOOD FLOATING FLOOR K11 K11/225 PARTICLEBOARD FLOATING FLOOR K11 K11/235 ORIENTED STRAND BOARD FLOATING FLOOR K11 K11/245 CEMENT BONDED PARTICLEBOARD FLOATING FLOOR K11 K11/275 ACOUSTIC SEPARATING FLOOR SYSTEM K11 K11/295 FLOATING FLOOR SYSTEM K11 K11/315 PLYWOOD FLOORING K11 K11/325 PARTICLEBOARD FLOORING K11 K11/335 ORIENTED STRAND BOARD FLOORING K11 K11/345 CEMENT BONDED PARTICLEBOARD FLOORING K11 K11/415 PLYWOOD WALL SHEATHING K11 K11/435 ORIENTED STRAND BOARD WALL SHEATHING K11 K11/465 IMPREGNATED SOFTBOARD WALL SHEATHING K11 K11/485 WALL SHEATHING K11 K11/495 RIGID BOARD INSULATION FIXED THROUGH WALL SHEATHING K11 K11/515 PLYWOOD ROOF DECKING K11 K11/525 PARTICLEBOARD ROOF DECKING K11 K11/535 ORIENTED STRAND BOARD ROOF DECKING K11 K11/585 ROOF DECKING K11 K11/615 PLYWOOD SARKING K11 K11/625 PARTICLEBOARD SARKING K11 K11/635 ORIENTED STRAND BOARD SARKING K11 K11/665 IMPREGNATED SOFTBOARD SARKING K11 K11/685 SARKING K11 K11/695 RIGID BOARD INSULATION FIXED AS ROOF SARKING K11 K11/715 PLYWOOD UNDERLAY K11 K11/755 HARDBOARD UNDERLAY K11 K11/795 WALL LINING ON METAL FRAMING K11 K11/796 METAL STUD PARTITION SYSTEM K11 K11/815 PLYWOOD K11 K11/816 MARINE PLYWOOD K11 K11/820 BLOCKBOARD/ LAMINBOARD K11 K11/825 PARTICLEBOARD K11 K11/845 CEMENT BONDED PARTICLEBOARD K11 K11/851 WOOD WOOL BOARD/ SLAB K11 K11/855 HARDBOARD K11 K11/860 MEDIUM BOARD K11 K11/865 SOFTBOARD K11 K11/875 MEDIUM DENSITY FIBREBOARD K11 K11/880 LAMINATED PLASTICS VENEERED BOARD K11 K11/885 FIRE PROTECTION BOARD K11 K11/890 BOARD K11 K11/910 INSTALLATION GENERALLY K11 K11/915 DRYNESS OF CONCRETE/ SCREED SUBSTRATES FOR FLOATING FLOORS K11 K11/920 VAPOUR CONTROL LAYER IN FLOATING FLOOR CONSTRUCTION K11 K11/925 BATTENS FOR FLOATING FLOORS K11 K11/930 ADDITIONAL SUPPORTS K11 K11/940 BOARD MOISTURE CONTENT AND CONDITIONING K11 K11/950 MOISTURE CONTENT TESTING K11 K11/960 FIXING GENERALLY K11 K11/975 METAL WALL FRAMING K11 K11/976 MINERAL WOOL INSULATION TO METAL FRAMING K11 K11/980 OPEN JOINTS K11 K11/990 ACCESS PANELS K11 K13 RIGID SHEET FINE LININGS AND PANELLING K K13/110 WOOD PANELLING K13 K13/120 WOOD VENEERED PANEL LINING K13 K13/130 LAMINATED PLASTICS VENEERED PANEL LINING K13 K13/140 PROPRIETARY LAMINATED PLASTICS VENEERED PANEL LINING K13 K13/145 PROPRIETARY PLASTICS CLADDING K13 K13/150 PURPOSE MADE K13 K13/160 PROPRIETARY K13 K13/170 ACOUSTIC PANEL LINING K13 K13/210 ADVANCE REGISTRATION K13 K13/220 MATERIAL SAMPLES K13 K13/230 CONTROL SAMPLES K13 K13/260 ENVIRONMENTAL CONDITIONS K13 K13/270 HEATING SYSTEM K13 K13/280 AIR CONDITIONING SYSTEM K13 K13/310 ACCURACY OF FABRICATION K13 K13/320 LAMINATED TIMBER CORES FOR WOOD VENEERED PANELS K13 K13/340 HOLES/ CUT OUTS IN LAMINATED PLASTICS VENEERS K13 K13/350 FIXING LININGS AND PANELLING K13 K13/360 OPEN JOINTS (JOINTS WITHOUT COVER STRIPS OR SIMILAR) K13 K13/370 SEALANT POINTING K13 K13/400 DOOR FRAMES K13 K13/410 FIRE RESISTING FRAMES K13 K13/430 HANGING OF PREFINISHED DOORS K13 K13/440 IRONMONGERY K13 K13/480 CLEAR FINISHED WOOD K13 K20 TIMBER BOARD FLOORING/ SARKING/ LININGS/ CASINGS K K20/110 TIMBER BOARD FLOORING K20 K20/150 BATTENED TIMBER BOARD FLOATING FLOOR K20 K20/220 TIMBER BOARD SARKING K20 K20/230 TIMBER BOARD K20 K20/310 WORKMANSHIP GENERALLY K20 K20/320 MOISTURE CONTENT OF NEW CONCRETE/ SCREED SUBSTRATES FOR FLOATING FLOORS K20 K20/330 MOISTURE CONTENT OF TIMBER K20 K20/340 INSTALLING VAPOUR CHECK MEMBRANE TO FLOATING FLOORS K20 K20/345 BATTENS FOR FLOATING FLOORS K20 K20/347 BATTENS FOR FLOATING FLOORS K20 K20/350 TREATED TIMBER K20 K20/360 ACCESS PANELS K20 K20/370 FIXING BOARDS K20 K21 WOOD STRIP/ BOARD FINE FLOORING/ LININGS K K21/110 WOOD FLOORING K21 K21/111 WOOD FLOATING FLOOR K21 K21/115 WOOD LAMINATE FLOORING K21 K21/120 BATTENED WOOD FLOORING K21 K21/130 BATTENED WOOD FLOATING FLOOR K21 K21/140 BATTENED WOOD LAMINATE FLOORING K21 K21/145 COMPOSITE LAMINATE FLOORING K21 K21/146 LAMINATE FLOORING K21 K21/150 WOOD LINING K21 K21/160 WOOD LINING ON BATTENS K21 K21/170 FLOOR FINISH MATERIALS SPECIFICATION K21 K21/210 WORKMANSHIP GENERALLY K21 K21/220 ENVIRONMENTAL CONDITIONS K21 K21/230 HEATING SYSTEM K21 K21/240 AIR CONDITIONING SYSTEM K21 K21/250 FIXTURES K21 K21/260 DRYNESS OF CONCRETE/ SCREED SUBSTRATES FOR FLOORING K21 K21/270 STRIP/ BOARD MOISTURE CONTENT TESTING K21 K21/280 EXISTING WOOD FLOORING K21 K21/290 CONTROL SAMPLES K21 K21/310 VAPOUR CONTROL LAYER INSTALLATION K21 K21/325 FLOORING BATTENS K21 K21/330 FIXING BATTENS K21 K21/335 TREATED TIMBER K21 K21/340 ACCESS PANELS K21 K21/350 FIXING STRIPS/ BOARDS K21 K21/360 EXPANSION PROVISION K21 K21/370 FINISH TO FLOORING K21 K21/380 FINISH TO LINING K21 K30 PANEL PARTITIONS K K30/105 TIMBER PROCUREMENT K30 K30/110 RELOCATABLE PARTITION SYSTEM K30 K30/115 RELOCATABLE PARTITION/ CEILING SYSTEM K30 K30/130 RELOCATABLE PARTITION SYSTEM K30 K30/135 RELOCATABLE PARTITION/ CEILING SYSTEM K30 K30/150 PLASTERBOARD PANEL PARTITIONS K30 K30/160 PLASTERBOARD LAMINATED PARTITIONS K30 K30/170 MESH PANEL PARTITIONS K30 K30/250 STORAGE WALLS K30 K30/260 MEDIA WALLS K30 K30/310 COMPLIANCE WITH PERFORMANCE REQUIREMENTS K30 K30/320 SAMPLES K30 K30/330 CONTROL SAMPLES K30 K30/340 ENVIRONMENTAL CONDITIONS K30 K30/355 MOISTURE CONTENT OF TIMBER COMPONENTS K30 K30/365 TIMBER FOR PLASTERBOARD PARTITIONS K30 K30/375 NEW WET LAID BASES K30 K30/380 COORDINATION WITH OTHERS K30 K30/410 WORKMANSHIP GENERALLY K30 K30/425 INSTALLING RELOCATABLE PARTITIONS K30 K30/435 INSTALLING PLASTERBOARD PANEL PARTITIONS K30 K30/436 ADDITIONAL LININGS TO PLASTERBOARD PANEL PARTITIONS K30 K30/445 INSTALLING PLASTERBOARD LAMINATED PARTITIONS K30 K30/455 TAPED SEAMLESS FINISH TO PLASTERBOARD PARTITIONS K30 K30/470 PERIMETER SEALS K30 K30/475 FIRE STOPPING K30 K30/480 GLAZING FOR RELOCATABLE PARTITIONS K30 K30/490 IRONMONGERY FOR RELOCATABLE PARTITIONS K30 K30/495 POST INSTALLATION REQUIREMENTS FOR RELOCATABLE PARTITIONS K30 K32 PANEL CUBICLES/ DUCT AND WALL LININGS/ SCREENS K K32/112 FULLY FRAMED PANEL CUBICLES K32 K32/120 PANEL CUBICLES K32 K32/130 PRIVACY SCREENS K32 K32/140 DUCT/ WALL LININGS – PANELS ONLY K32 K32/150 DUCT/ WALL LININGS – PANELS AND PROPRIETARY FRAMES K32 K32/160 DUCT LININGS – PREPLUMBED PANELS AND PROPRIETARY FRAMES K32 K32/180 DUCT PANEL SUPPORT FRAMING – SITE FABRICATED SOFTWOOD K32 K32/210 SAMPLES K32 K32/220 CONTROL SAMPLES K32 K32/250 INSTALLATION K32 K40 DEMOUNTABLE SUSPENDED CEILINGS K K40/105 SUSPENDED CEILING SYSTEM K40 K40/115 UNIT SUSPENDED CEILING SYSTEM K40 K40/135 BOARD SUSPENDED CEILING SYSTEM K40 K40/140 FABRIC MEMBRANE CEILING SYSTEM K40 K40/205 COMPLIANCE WITH PERFORMANCE REQUIREMENTS K40 K40/210 ENVIRONMENT K40 K40/220 STRUCTURAL PERFORMANCE K40 K40/225 FIRE PERFORMANCE K40 K40/230 ACOUSTIC PERFORMANCE K40 K40/240 SAMPLES K40 K40/245 STANDARDS K40 K40/250 SUSPENSION SYSTEM K40 K40/255 EDGE BATTENS K40 K40/260 PERIMETER TRIMS K40 K40/265 INFILL UNITS K40 K40/270 BOARDS K40 K40/275 FABRIC MEMBRANES K40 K40/280 ACCESS UNITS K40 K40/285 INSULATION K40 K40/287 CAVITY BARRIERS K40 K40/290 AIR PLENUM BARRIERS K40 K40/302 CONTROL SAMPLES K40 K40/305 SETTING OUT K40 K40/310 BRACING K40 K40/315 PROTECTION K40 K40/320 TOP FIXING K40 K40/325 INSTALLING HANGERS K40 K40/330 INSTALLING TIMBER EDGE BATTENS K40 K40/335 INSTALLING PERIMETER TRIMS K40 K40/340 EXPOSED GRIDS K40 K40/345 CONCEALED GRIDS K40 K40/355 INSTALLING INFILL UNITS K40 K40/365 INSTALLING METAL INFILL UNITS K40 K40/375 BOARD CEILING SYSTEMS K40 K40/385 UPSTANDS AND BULKHEADS K40 K40/390 OPENINGS IN CEILING MATERIALS K40 K40/395 INTEGRATED SERVICES K40 K40/401 CEILING MOUNTED LUMINAIRES K40 K40/406 TRUNKING K40 K40/411 MECHANICAL SERVICES K40 K40/415 INSTALLING INSULATION K40 K40/421 CEILING SYSTEMS INTENDED FOR FIRE PROTECTION K40 K40/425 INSTALLING CAVITY FIRE BARRIERS K40 K40/431 INSTALLING SOUND BARRIERS K40 K40/435 INSTALLING AIR PLENUM BARRIERS K40 K40/500 ELECTRICAL CONTINUITY AND EARTH BONDING K40 K40/505 TOOLS K40 K40/520 USER INSTRUCTIONS K40 K40/530 SPARES K40 K41 RAISED ACCESS FLOORS K K41/110 RAISED ACCESS FLOOR K41 K41/120 RAISED ACCESS FLOOR K41 K41/130 RAISED ACCESS FLOOR K41 K41/210 GENERAL PERFORMANCE K41 K41/219 INSTALLATION K41 K41/229 HYGROTHERMAL PERFORMANCE K41 K41/234 FIRE PERFORMANCE K41 K41/239 SOUND TRANSMISSION K41 K41/249 FLOOR VOID (PLENUM) AIR LEAKAGE K41 K41/310 SAMPLES K41 K41/315 FLOOR PANELS K41 K41/320 PEDESTALS K41 K41/322 PEDESTAL ADHESIVE K41 K41/325 STRINGERS K41 K41/331 INTEGRAL FLOOR PANEL COVERINGS K41 K41/340 CAVITY BARRIERS K41 K41/350 UNDER FLOOR TRUNKING K41 K41/360 SERVICE OUTLET BOXES K41 K41/370 AIR HANDLING SYSTEM ACCESSORIES K41 K41/380 LEVEL CHANGE ACCESSORIES K41 K41/390 SUNDRY ACCESSORIES K41 K41/410 CONTROL SAMPLES K41 K41/421 PREPARATION K41 K41/425 ENVIRONMENTAL CONDITIONS K41 K41/431 DUSTPROOFING K41 K41/433 PEDESTAL ADHESIVE TESTING K41 K41/435 CUT FLOOR PANELS K41 K41/441 RAISED ACCESS FLOOR LEVELS K41 K41/445 PERIMETERS K41 K41/455 LEVEL CHANGES K41 K41/460 UNDER-FLOOR PLENUM AIR BARRIERS K41 K41/465 ELECTRICAL CONTINUITY AND EARTH BONDING K41 K41/470 INTEGRAL FINISHES ELECTRICAL RESISTANCE TESTING K41 K41/510 TOOLS K41 K41/515 USER INSTRUCTIONS K41 K41/520 SPARES K41 K41/525 CLEANING K41 K45 SUSPENDED CEILING SYSTEM ALTERATIONS K K45/110 DEFINITIONS K45 K45/120 EXISTING SUSPENDED CEILING SYSTEM K45 K45/130 UNIT SUSPENDED CEILING SYSTEM ALTERATIONS K45 K45/160 BOARD SUSPENDED CEILING SYSTEM ALTERATIONS K45 K45/310 PRODUCTS GENERALLY K45 K45/315 SUSPENSION SYSTEM K45 K45/350 BOARDS K45 K45/370 INFILL UNITS K45 K45/390 ACCESS UNITS K45 K45/400 ACCESSORIES K45 K45/405 TIMBER EDGE BATTENS K45 K45/410 AIR PLENUM BARRIERS K45 K45/415 CAVITY FIRE BARRIERS K45 K45/425 INSULATION K45 K45/610 PREPARATION K45 K45/620 EXECUTION GENERALLY K45 K45/650 SETTING OUT K45 K45/670 INSTALLING SUSPENSION K45 K45/675 INSTALLING PERIMETER TRIMS K45 K45/680 INSTALLING BOARDS K45 K45/700 COORDINATION WITH SERVICES K45 K45/710 INTEGRATED SERVICES K45 K45/715 LUMINAIRES K45 K45/720 MECHANICAL SERVICES K45 K45/725 OTHER SERVICES K45 K45/730 INSTALLING INSULATION K45 K45/735 INSTALLING CAVITY FIRE BARRIERS K45 K45/805 ELECTRICAL CONTINUITY AND EARTH BONDING K45 K45/910 DOCUMENTATION K45 K45/920 SPARES K45 K45/930 TOOLS K45 K46 RAISED ACCESS FLOOR SYSTEM ALTERATIONS K K46/110 DEFINITIONS K46 K46/120 EXISTING RAISED ACCESS FLOOR SYSTEM K46 K46/130 RAISED ACCESS FLOOR SYSTEM ALTERATIONS K46 K46/210 PERFORMANCE REQUIREMENTS K46 K46/220 PERFORMANCE REQUIREMENTS K46 K46/310 PRODUCTS GENERALLY K46 K46/315 SUBFLOOR SEALER K46 K46/320 PEDESTALS K46 K46/330 ADDITIONAL STRUCTURAL ELEMENTS K46 K46/340 FLOOR PANELS K46 K46/350 FLOOR COVERINGS K46 K46/360 PERIMETER EDGING K46 K46/381 UNDER FLOOR TRUNKING K46 K46/382 SERVICE OUTLET BOXES K46 K46/383 AIR HANDLING SYSTEM ACCESSORIES K46 K46/390 UNDER FLOOR ACOUSTIC BARRIERS K46 K46/400 CAVITY BARRIERS K46 K46/610 PREPARATION K46 K46/620 EXECUTION GENERALLY K46 K46/630 FLOOR SEALING K46 K46/640 LEVEL CHANGES K46 K46/650 CUT FLOOR PANELS K46 K46/660 PERIMETER EDGING K46 K46/670 UNDER-FLOOR PLENUM AIR BARRIERS K46 K46/680 CAVITY BARRIERS K46 K46/690 COORDINDATION WITH SERVICES K46 K46/700 ELECTRICAL CONTINUITY AND EARTH BONDING K46 K46/720 GENERAL ROOM CONDITIONS K46 K46/910 ELECTRICAL CONTINUITY AND EARTH BONDING TEST K46 K46/920 DOCUMENTATION K46 K46/930 SPARES K46 K46/940 TOOLS K46 L WINDOWS/ DOORS/ STAIRS L10 WINDOWS/ ROOFLIGHTS/ SCREENS/ LOUVRES L L10/110 EVIDENCE OF PERFORMANCE L10 L10/115 TIMBER PROCUREMENT L10 L10/120 SITE DIMENSIONS L10 L10/140 CONTROL SAMPLES L10 L10/150 DAYLIGHT PERFORMANCE L10 L10/155 VIEW OUT L10 L10/160 POTENTIAL FOR NATURAL VENTILATION L10 L10/205 WINDOW MATERIALS SPECIFICATION L10 L10/210 WOOD WINDOWS L10 L10/250 WOOD WINDOWS L10 L10/260 WOOD WINDOWS L10 L10/310 STEEL WINDOWS L10 L10/315 STEEL WINDOWS L10 L10/330 ALUMINIUM WINDOWS L10 L10/335 ALUMINIUM WINDOWS L10 L10/350 PVC-U WINDOWS L10 L10/360 PVC-U WINDOWS L10 L10/380 PVC-U WINDOWS L10 L10/390 PROPRIETARY WINDOWS L10 L10/400 COMPOSITE WINDOWS L10 L10/410 COMPOSITE WINDOWS L10 L10/420 WOOD SUBFRAMES L10 L10/440 PVC-U SUBFRAMES L10 L10/460 ROOFLIGHTS L10 L10/480 ROOF WINDOWS L10 L10/490 ROOF VENTILATORS L10 L10/495 DAYLIGHT PIPE L10 L10/510 GLAZED WOOD SCREENS L10 L10/550 GLAZED METAL SCREENS L10 L10/560 GLAZED SCREEN SYSTEM L10 L10/580 SECONDARY GLAZING SYSTEM L10 L10/605 WOOD LOUVRES L10 L10/610 WOOD LOUVRES L10 L10/650 METAL LOUVRES L10 L10/670 BRISE SOLEIL L10 L10/680 SOLAR SHADING SYSTEM L10 L10/690 SECURITY L10 L10/710 PROTECTION OF COMPONENTS L10 L10/730 PRIMING/ SEALING L10 L10/740 CORROSION PROTECTION L10 L10/750 BUILDING IN L10 L10/755 PVC-U WINDOW INSTALLATION L10 L10/760 REPLACEMENT WINDOW INSTALLATION L10 L10/765 WINDOW INSTALLATION GENERALLY L10 L10/766 LOCATION OF OPENABLE WINDOWS IN NATURALLY VENTILATED BUILDINGS L10 L10/770 DAMP PROOF COURSES IN PREPARED OPENINGS L10 L10/780 FIXING OF WOOD FRAMES L10 L10/781 FIXING OF STEEL FRAMES L10 L10/782 FIXING OF ALUMINIUM FRAMES L10 L10/783 FIXING OF PVC-U FRAMES L10 L10/784 FIXING OF COMPOSITE FRAMES L10 L10/790 FIRE RESISTING FRAMES L10 L10/800 BACKFILLING OF STEEL FRAME SECTIONS L10 L10/810 SEALANT JOINTS L10 L10/820 IRONMONGERY L10 L20 DOORS/ SHUTTERS/ HATCHES L L20/110 EVIDENCE OF PERFORMANCE L20 L20/112 TIMBER PROCUREMENT L20 L20/115 FIRE RESISTING DOORS/ DOORSETS/ ASSEMBLIES L20 L20/120 NON FIRE RESISTING DOORS/ DOORSETS/ ASSEMBLIES L20 L20/150 SITE DIMENSIONS L20 L20/170 CONTROL SAMPLES L20 L20/210 MATCHBOARDED DOORS L20 L20/215 EXTERNAL MATCHBOARDED DOORS L20 L20/230 WOOD FLUSH DOORS L20 L20/250 WOOD PANELLED DOORS L20 L20/270 WOOD DOORS L20 L20/280 DOORS L20 L20/310 WOOD DOOR FRAMES L20 L20/330 WOOD DOOR FRAMES L20 L20/370 DOOR FRAMES L20 L20/410 WOOD DOORSETS L20 L20/420 WOOD DOORSETS L20 L20/430 WOOD DOORSETS L20 L20/460 FRAMELESS GLASS DOORS L20 L20/480 DOORSETS L20 L20/490 AUTOMATIC DOORS L20 L20/495 AUTOMATIC REVOLVING DOORS L20 L20/500 MANUAL REVOLVING DOORS L20 L20/510 STRONG ROOM DOOR L20 L20/515 BLAST RESISTANT DOOR L20 L20/520 SLIDING DOORS L20 L20/525 SLIDING POCKET DOORS L20 L20/530 SLIDING FOLDING EXTERNAL DOORS L20 L20/535 SLIDING FOLDING SHUTTER DOORS L20 L20/540 SLIDING FOLDING L20 L20/545 SLIDING STACKING PANEL PARTITIONS L20 L20/550 FLEXIBLE DOORS L20 L20/560 PVC STRIP CURTAINS L20 L20/570 HIGH SPEED DOORS L20 L20/610 ROLLER SHUTTERS/ CURTAINS L20 L20/612 ROLLER GRILLES L20 L20/615 SECTIONAL OVERHEAD DOORS L20 L20/617 LOADING BAY DOOR AND DOCKING SYSTEM L20 L20/620 COLLAPSIBLE GATES/ GRILLES L20 L20/630 HATCHES L20 L20/680 UP AND OVER GARAGE DOORS L20 L20/710 PROTECTION OF COMPONENTS L20 L20/730 PRIMING/ SEALING L20 L20/740 CORROSION PROTECTION L20 L20/750 FIXING DOORSETS L20 L20/760 BUILDING IN L20 L20/770 DAMP PROOF COURSES ASSOCIATED WITH BUILT IN WOOD FRAMES L20 L20/780 DAMP PROOF COURSES IN PREPARED OPENINGS L20 L20/790 FIXING OF WOOD FRAMES L20 L20/800 FIXING OF LOOSE THRESHOLDS L20 L20/809 FIRE RESISTING/ SMOKE CONTROL DOORS/ DOORSETS/ ROLLER SHUTTERS/ CURTAINS L20 L20/810 FIRE RESISTING/ SMOKE CONTROL DOORS/ DOORSETS/ ROLLER SHUTTERS/ CURTAINS L20 L20/820 SEALANT JOINTS L20 L20/830 FIXING IRONMONGERY GENERALLY L20 L20/840 FIXING IRONMONGERY TO FIRE RESISTING DOOR ASSEMBLIES L20 L20/850 LOCATION OF HINGES L20 L20/860 INSTALLATION OF EMERGENCY EXIT DEVICES L20 L30 STAIRS/ LADDERS/ WALKWAYS/ HANDRAILS/ BALUSTRADES L L30/105 CONTRACTOR'S DESIGN L30 L30/107 COMPLETION OF DESIGN L30 L30/109 STRUCTURAL DESIGN PROVIDED L30 L30/115 TIMBER PROCUREMENT L30 L30/130 SITE DIMENSIONS L30 L30/210 WOOD STAIRS L30 L30/230 INTERNAL WOOD STAIRS L30 L30/235 EXTERNAL WOOD STAIRS L30 L30/250 METAL STAIRS L30 L30/270 STAIRS L30 L30/310 PROPRIETARY L30 L30/410 STEEL LADDERS L30 L30/421 LOFT LADDERS L30 L30/460 WALKWAYS L30 L30/470 RAMPS L30 L30/510 WOOD BALUSTRADES L30 L30/515 WOOD BALUSTRADES L30 L30/550 PURPOSE MADE BALUSTRADES L30 L30/560 PROPRIETARY BALUSTRADES L30 L30/570 PURPOSE MADE HANDRAILS L30 L30/580 PROPRIETARY HANDRAILS L30 L30/585 APPLIED SLIP RESISTANT L30 L30/590 APPLIED STAIR NOSINGS L30 L30/592 TRIMS/ EDGINGS L30 L30/610 MOISTURE CONTENT L30 L30/620 PRIMING/SEALING/PAINTING L30 L30/630 CORROSION PROTECTION OF DISSIMILAR MATERIALS L30 L30/640 INSTALLATION GENERALLY L30 L30/670 INSTALLATION OF TREAD INSERTS/ NOSINGS L30 L30/910 INSPECTION L30 L30/915 SLIP RESISTANCE TESTING L30 L30/920 DOCUMENTATION L30 L35 FIXED UTILITARIAN ACCESS SYSTEMS L L35/110 COMPANIONWAY SYSTEM L35 L35/120 DUCKBOARD SYSTEM L35 L35/130 LADDER SYSTEM L35 L35/140 HIGH LEVEL WALKWAY SYSTEM L35 L35/150 STAIR SYSTEM L35 L35/160 WORKING PLATFORM SYSTEM L35 L35/170 GUARDING SYSTEM L35 L35/212 CONTRACTOR'S DESIGN L35 L35/214 COMPLETION OF DESIGN L35 L35/240 STRUCTURAL DESIGN PROVIDED L35 L35/310 COMPANIONWAYS L35 L35/320 DUCKBOARDS L35 L35/330 LADDERS L35 L35/340 HIGH LEVEL WALKWAYS L35 L35/350 STAIRS L35 L35/360 WORKING PLATFORMS L35 L35/370 GUARDINGS L35 L35/410 ALUMINIUM COMPONENTS L35 L35/420 CARBON STEEL COMPONENTS L35 L35/440 STAINLESS STEEL COMPONENTS L35 L35/460 CAST IRON COMPONENTS L35 L35/470 GRP COMPONENTS L35 L35/490 ANCHORS L35 L35/510 FABRICATION GENERALLY L35 L35/620 EXECUTION GENERALLY L35 L35/660 ANCHORING L35 L35/910 CLEANING L35 L35/920 INSPECTION L35 L35/930 DOCUMENTATION L35 L37 EXTERNAL STAIR, RAMPS, HANDRAIL AND BALUSTRADES SYSTEMS L L37/110 STAIR SYSTEMS L37 L37/120 RAMP SYSTEMS L37 L37/130 STEPPED RAMP SYSTEMS L37 L37/150 HANDRAIL SYSTEMS L37 L37/160 BALUSTRADE SYSTEMS L37 L37/210 DESIGN L37 L37/220 DESIGN L37 L37/310 PRECAST CONCRETE STEP UNIT L37 L37/315 MANUFACTURED STONE STEP UNIT L37 L37/320 METAL STEP UNIT L37 L37/325 PLASTICS COMPOSITE STEP UNIT L37 L37/350 GLAZED PANELS L37 L37/360 METAL PANELS L37 L37/370 MANUFACTURED STONE BALUSTERS L37 L37/375 MANUFACTURED STONE CAPPING RAILS L37 L37/380 MANUFACTURED STONE PLINTH L37 L37/385 MANUFACTURED STONE PIER L37 L37/410 APPLIED SLIP RESISTANT L37 L37/420 APPLIED STAIR NOSINGS L37 L37/510 FABRICATION GENERALLY L37 L37/610 LOADING L37 L37/620 CONCRETE FOUNDATIONS GENERALLY L37 L37/630 SETTING COMPONENTS IN CONCRETE L37 L37/640 PRESERVATIVE TREATED TIMBER L37 L37/650 INSTALLATION GENERALLY L37 L37/660 INSTALLATION OF MANUFACTURED STONE ELEMENTS L37 L37/662 ADVERSE WEATHER L37 L37/670 INSTALLATION OF TREAD INSERTS/ NOSINGS L37 L37/680 SITE PAINTING AND STAINING L37 L37/910 INSPECTION L37 L37/915 SLIP RESISTANCE TESTING L37 L37/920 DOCUMENTATION L37 L40 GENERAL GLAZING L L40/110 PREGLAZING L40 L40/111 PREGLAZING L40 L40/130 REMOVAL OF GLASS/ PLASTICS FOR REUSE L40 L40/140 MATERIAL SAMPLES L40 L40/150 WORKMANSHIP GENERALLY L40 L40/151 PREPARATION L40 L40/152 PREPARATION L40 L40/155 GLASS GENERALLY L40 L40/160 LINEAR PATTERNED/ WIRED GLASS L40 L40/165 HEAT SOAKING OF THERMALLY TOUGHENED GLASS L40 L40/170 PLASTICS GLAZING SHEET L40 L40/180 BEAD FIXING WITH PINS L40 L40/181 BEAD FIXING WITH SCREWS L40 L40/190 GLASS TO GLASS JOINTING L40 L40/195 GLASS TO GLASS JOINTING L40 L40/210 PUTTY FRONTED SINGLE GLAZING L40 L40/230 BEAD FIXED SINGLE GLAZING L40 L40/250 BEAD FIXED SINGLE GLAZING L40 L40/260 BEAD FIXED SINGLE GLAZING L40 L40/310 BEAD FIXED SINGLE GLAZING L40 L40/330 BEAD FIXED SINGLE GLAZING L40 L40/350 BEAD FIXED SINGLE GLAZING L40 L40/370 BEAD FIXED INSULATING GLASS UNITS L40 L40/371 BEAD FIXED INSULATING GLASS UNITS L40 L40/372 BEAD FIXED INSULATING GLASS UNITS L40 L40/380 BEAD FIXED INSULATING GLASS UNITS L40 L40/381 BEAD FIXED INSULATING GLASS UNITS L40 L40/410 SINGLE GLAZING INTO GROOVES L40 L40/430 SINGLE GLAZING INTO GROOVES L40 L40/450 SINGLE GLAZING INTO GROOVES L40 L40/470 ZIPPER GASKET GLAZING L40 L40/490 SINGLE SIDED GASKET GLAZING L40 L40/495 U-PROFILED SINGLE GLAZING L40 L40/496 U-PROFILED DOUBLE GLAZING L40 L40/505 FIRE RESISTANT TAPE/ STRIP GLAZING L40 L40/510 FIRE RESISTANT CHANNEL GLAZING L40 L40/515 FIRE RESISTANT CHANNEL GLAZING L40 L40/520 FIRE RATING L40 L40/530 INTERNAL TAPE GLAZING L40 L40/550 GLASS MIRRORS L40 L40/560 PLASTICS MIRRORS L40 L40/610 WINDOW FILM L40 L40/630 MANIFESTATION L40 M SURFACE FINISHES M10 CEMENT BASED LEVELLING/ WEARING SCREEDS M M10/110 BONDED CEMENT:SAND LEVELLING SCREEDS M10 M10/115 CEMENT:SAND LEVELLING SCREEDS M10 M10/120 FINE CONCRETE LEVELLING SCREEDS M10 M10/130 PROPRIETARY QUICK DRYING LEVELLING SCREEDS M10 M10/140 PROPRIETARY POLYMER MODIFIED LEVELLING SCREEDS M10 M10/150 PROPRIETARY LIGHTWEIGHT AGGREGATE LEVELLING SCREEDS M10 M10/155 CEMENT SAND SURFACING TO LIGHTWEIGHT AGGREGATE LEVELLING SCREEDS M10/ M10 M10/157 PROPRIETARY SURFACING TO LIGHTWEIGHT AGGREGATE LEVELLING SCREEDS M10/ M10 M10/160 PROPRIETARY SELF SMOOTHING LEVELLING SCREEDS M10 M10/165 PROPRIETARY FIBRE REINFORCED LEVELLING SCREEDS M10 M10/180 CONCRETE WEARING SCREEDS (GRANOLITHIC) M10 M10/185 PROPRIETARY POLYMER MODIFIED WEARING SCREEDS M10 M10/192 PROPRIETARY SELF SMOOTHING WEARING SCREEDS M10 M10/205 DESIGN LIFE OF SCREEDS M10 M10/210 SUITABILITY OF SUBSTRATES M10 M10/215 SURFACE HARDNESS OF SUBSTRATES TO RECEIVE POLYMER MODIFIED WEARING SCREEDS M10 M10/220 PROPRIETARY LEVELLING/ WEARING SCREEDS M10 M10/230 CONTROL SAMPLES M10 M10/250 CONDUITS UNDER FLOATING SCREEDS M10 M10/251 CONDUITS CAST INTO OR UNDER SCREEDS M10 M10/255 PIPE DUCTS/ TRUNKING M10 M10/260 FULLY BONDED CONSTRUCTION M10 M10/270 PARTIALLY BONDED CONSTRUCTION M10 M10/275 CEMENT SLURRY BONDING M10 M10/280 UNBONDED CONSTRUCTION M10 M10/290 FLOATING CONSTRUCTION M10 M10/295 FLOATING CONSTRUCTION (THIN SHEET IMPACT SOUND INSULATION) M10 M10/302 CEMENTS M10 M10/305 AGGREGATES M10 M10/306 PROPRIETARY POLYMER MODIFIED SCREEDS M10 M10/307 ADMIXTURES M10 M10/310 BATCHING WITH DENSE AGGREGATES M10 M10/311 BATCHING WITH LIGHTWEIGHT AGGREGATES M10 M10/330 MIXING M10 M10/335 IN SITU CRUSHING RESISTANCE (ISCR) M10 M10/340 ADVERSE WEATHER M10 M10/345 LEVEL OF SCREED SURFACES M10 M10/350 SCREEDING TO FALLS M10 M10/351 SCREEDING TO RAMPS M10 M10/355 FLATNESS/ SURFACE REGULARITY OF FLOOR SCREEDS M10 M10/365 FLATNESS/SURFACE REGULARITY OF ROOF SCREEDS M10 M10/375 COMPACTION OF SCREEDS M10 M10/382 STAIR SCREEDS M10 M10/386 COVED IN SITU SKIRTINGS M10 M10/392 GENERAL REINFORCEMENT M10 M10/395 STRIP REINFORCEMENT M10 M10/405 JOINTS IN LEVELLING SCREEDS GENERALLY M10 M10/406 BAY JOINTS IN LEVELLING SCREEDS M10 M10/415 BAY JOINTS IN BONDED WEARING SCREEDS M10 M10/428 HEATED SCREEDS M10 M10/435 FORMED JOINTS IN WEARING SCREEDS M10 M10/440 CRACK INDUCING GROOVES IN LEVELLING SCREEDS M10 M10/445 CRACK INDUCING GROOVES IN WEARING SCREEDS M10 M10/450 SEALANT FOR SAWN JOINTS IN WEARING SCREEDS M10 M10/452 SEALING STRIPS FOR SAWN JOINTS IN WEARING SCREEDS M10 M10/460 STRIP MOVEMENT JOINTS M10 M10/468 SEALANT MOVEMENT JOINTS WITH METAL EDGINGS M10 M10/476 METAL SECTION MOVEMENT JOINTS M10 M10/510 FINISHING GENERALLY M10 M10/520 WOOD FLOATED FINISH M10 M10/530 SMOOTH FLOATED FINISH M10 M10/540 TROWELLED FINISH TO LEVELLING SCREEDS M10 M10/550 TROWELLED FINISH TO WEARING SCREEDS M10 M10/560 DEWATERED TROWELLED FINISH TO WEARING SCREEDS M10 M10/600 POWER GROUND FINISH TO WEARING SCREEDS M10 M10/650 CURING M10 M10/670 ROOF SCREEDS M10 M10/680 SURFACE SEALER TO WEARING SCREEDS M10 M10/690 SLIP RESISTANCE TEFCSTING OF WEARING SCREEDS M10 M10/700 ABRASION TESTING OF WEARING SCREEDS M10 M11 MASTIC ASPHALT FLOORING/ FLOOR UNDERLAYS M M11/110 MASTIC ASPHALT FLOORING M11 M11/120 MASTIC ASPHALT FLOORING M11 M11/140 MASTIC ASPHALT FLOORING M11 M11/150 MASTIC ASPHALT FLOORING M11 M11/170 MASTIC ASPHALT FLOORING M11 M11/180 MASTIC ASPHALT FLOORING M11 M11/190 FLOORING MATERIALS SPECIFICATION M11 M11/210 MASTIC ASPHALT FLOOR UNDERLAY M11 M11/220 MASTIC ASPHALT FLOOR UNDERLAY M11 M11/230 MASTIC ASPHALT FLOOR UNDERLAY M11 M11/250 MASTIC ASPHALT SKIRTINGS M11 M11/260 MASTIC ASPHALT SKIRTINGS M11 M11/270 MASTIC ASPHALT SKIRTINGS M11 M11/320 CONTROL SAMPLES M11 M11/410 REMOVING EXISTING POLISH M11 M11/420 REMOVING EXISTING MASTIC ASPHALT M11 M11/450 SUITABILITY OF SUBSTRATES M11 M11/470 KEYING TO NEW BRICKWORK/ DENSE BLOCKWORK M11 M11/480 KEYING TO EXISTING BRICKWORK/ DENSE BLOCKWORK M11 M11/490 KEYING TO VERTICAL/ SLOPING DENSE CONCRETE M11 M11/495 KEYING TO METAL SURFACES M11 M11/500 METAL LATHING TO VERTICAL/ SLOPING SUBSTRATES M11 M11/550 SEPARATING LAYER M11 M11/580 REQUIREMENT FOR SEPARATING LAYER M11 M11/610 DELIVERY M11 M11/620 DELIVERY M11 M11/630 TRANSPORTING M11 M11/641 LOCALIZED HEATING M11 M11/650 PREPARING EDGES OF EXISTING MASTIC ASPHALT M11 M11/660 LAYING MASTIC ASPHALT M11 M11/670 ARMOURING M11 M11/710 SAND RUBBED FINISH M11 M11/720 NATURAL FLOAT FINISH M11 M11/725 SAND RUBBED FINISH TO RECEIVE APPLIED FLOOR FINISHES M11 M11/730 NATURAL FLOAT FINISH TO RECEIVE APPLIED FLOOR FINISHES M11 M11/740 CRIMPING M11 M11/750 LEVEL OF FINISHED MASTIC ASPHALT M11 M11/765 SLIP RESISTANCE TESTING OF FINISHED MASTIC ASPHALT FLOORING M11 M11/770 MASTIC ASPHALT SKIRTINGS M11 M11/810 STRUCTURAL MOVEMENT JOINTS M11 M11/820 PROPRIETARY STRUCTURAL MOVEMENT JOINTS M11 M11/830 STAIR NOSINGS/ TRIM M11 M11/840 EDGINGS/ COVER STRIPS M11 M11/850 APPLIED SLIP RESISTANT M11 M11/910 POLISHING M11 M11/920 OIL-RESISTANT FINISH M11 M11/930 COMPLETION M11 M11/940 MAINTENANCE REQUIREMENTS M11 M12 RESIN FLOORING M M12/110 RESIN FLOORING M12 M12/120 RESIN FLOORING M12 M12/130 FLOORING MATERIALS SPECIFICATION BRE ENVIRONMENTAL ASSESSMENT METHOD (BREEAM) RATING M12 M12/210 TESTING MOISTURE CONTENT OF SUBSTRATES M12 M12/220 SURFACE HARDNESS OF SUBSTRATES M12 M12/230 PREPARATION OF SUBSTRATES GENERALLY M12 M12/240 EXISTING SUBSTRATES M12 M12/250 EXISTING TILE/ SHEET FLOOR COVERINGS M12 M12/260 METAL SUBSTRATES M12 M12/310 WORKMANSHIP M12 M12/320 CONTROL SAMPLES M12 M12/330 PRIMERS M12 M12/340 REINFORCEMENT M12 M12/350 COATED RESIN FLOORING M12 M12/355 FLOW APPLIED COATED RESIN FLOORING M12 M12/357 TROWEL APPLIED SCREEDED RESIN FLOORING M12 M12/360 SURFACE ABRADING/ POLISHING M12 M12/370 SURFACE GRINDING/ GROUTING/ ABRADING/ POLISHING M12 M12/380 SURFACE SEALER M12 M12/390 SLIP RESISTANCE TESTING OF FINISHED RESIN FLOORING M12 M12/400 BOND STRENGTH OF RESIN FLOORING M12 M12/410 RESIN SKIRTINGS/ UPSTANDS M12 M12/420 FREE EDGES OF RESIN FLOORING M12 M12/430 SEALANT MOVEMENT JOINTS M12 M12/440 STRIP MOVEMENT JOINTS M12 M12/450 APPLIED SLIP RESISTANT ACCESSORIES M12 M13 CALCIUM SULFATE BASED LEVELLING SCREEDS M M13/110 PROPRIETARY TROWELLED LEVELLING SCREEDS M13 M13/120 PROPRIETARY SELF SMOOTHING LEVELLING SCREEDS M13 M13/210 DESIGN LIFE OF SCREEDS M13 M13/220 SUITABILITY OF SUBSTRATES M13 M13/230 CONDUITS UNDER FLOATING SCREEDS M13 M13/235 PIPE DUCTS/ TRUNKING M13 M13/250 UNBONDED CONSTRUCTION M13 M13/260 FLOATING CONSTRUCTION M13 M13/265 FLOATING CONSTRUCTION (THIN SHEET IMPACT SOUND INSULATION) M13 M13/270 FULLY BONDED CONSTRUCTION M13 M13/303 AGGREGATES M13 M13/305 BATCHING AGGREGATES M13 M13/310 MIXING TROWELLED SCREEDS M13 M13/315 MIXING SELF SMOOTHING SCREEDS M13 M13/320 ADVERSE WEATHER M13 M13/325 LEVEL OF SCREED SURFACES M13 M13/326 SCREEDING TO FALLS M13 M13/327 SCREEDING TO RAMPS (FALLS WITHIN SUBSTRATE) M13 M13/328 SCREEDING TO RAMPS (FALLS WITHIN SCREED) M13 M13/330 IN SITU CRUSHING RESISTANCE (ISCR) M13 M13/335 FLATNESS/ SURFACE REGULARITY OF SCREEDS M13 M13/345 LAYING TROWELLED SCREEDS M13 M13/355 LAYING SELF SMOOTHING SCREEDS M13 M13/365 HEATED SCREEDS M13 M13/375 STRIP MOVEMENT JOINTS M13 M13/385 SEALANT MOVEMENT JOINTS WITH METAL EDGINGS M13 M13/395 METAL SECTION MOVEMENT JOINTS M13 M13/410 TROWELLED FINISH TO SCREEDS M13 M13/420 SANDED SELF SMOOTHING FINISH M13 M13/430 CURING TROWELLED SCREEDS M13 M13/440 CURING SELF SMOOTHING SCREEDS M13 M20 PLASTERED/ RENDERED/ ROUGHCAST COATINGS M M20/10 CEMENT/ LIME/ SAND M20 M20/110 CEMENT:LIME:SAND M20 M20/120 CEMENT:LIME:SAND ROUGHCAST (HARLING) M20 M20/130 CEMENT:SAND (AIR ENTRAINED) M20 M20/140 CEMENT:SAND (AIR ENTRAINED) SUBSTRATES M20 M20/15 CEMENT/ LIME/ SAND ROUGHCAST (HARLING) M20 M20/160 PROPRIETARY CEMENT GAUGED RENDER M20 M20/19 PROPRIETARY RENDER M20 M20/200 GYPSUM PLASTER ON CEMENT GAUGED UNDERCOATS M20 M20/210 LIGHTWEIGHT GYPSUM PLASTER M20 M20/220 MULTICOAT PROPRIETARY PLASTER M20 M20/240 ONE COAT PROPRIETARY PLASTER M20 M20/25 GYPSUM PLASTER ON CEMENT GAUGED UNDERCOATS M20 M20/250 X-RAY PLASTER M20 M20/280 GYPSUM PLASTER SKIM COAT ON PLASTERBOARD M20 M20/290 PARGE COAT TO M20 M20/295 PROPRIETARY PARGE COAT TO M20 M20/30 LIGHTWEIGHT GYPSUM PLASTER M20 M20/310 LIME:SAND M20 M20/320 LIME:SAND ROUGHCAST (HARLING) M20 M20/330 PROPRIETARY LIME:SAND M20 M20/340 NONHYDRAULIC LIME:SAND PLASTER M20 M20/350 GYPSUM/ NONHYDRAULIC LIME:SAND PLASTER M20 M20/413 SAMPLES M20 M20/418 CONTROL SAMPLES M20 M20/42 PROPRIETARY PLASTER M20 M20/421 SCAFFOLDING M20 M20/424 SPECIAL PROTECTION OF HISTORIC PLASTERWORK M20 M20/430 READY-TO-USE CEMENT GAUGED RENDER MORTARS M20 M20/438 CEMENTS FOR MORTARS M20 M20/440 SAND FOR CEMENT GAUGED MORTARS M20 M20/443 LIME FOR CEMENT GAUGED MORTARS M20 M20/445 PIGMENT FOR COLOURED MORTARS M20 M20/449 ADMIXTURES FOR CEMENT GAUGED MORTARS M20 M20/450 CHLORIDE CONTENT OF MORTARS M20 M20/47 ONE COAT PROPRIETARY PLASTER M20 M20/478 HYDRAULIC LIME M20 M20/481 READY PREPARED LIME PUTTY M20 M20/491 POZZOLANIC ADDITIVES FOR NONHYDRAULIC LIME:SAND MORTARS M20 M20/492 HAIR REINFORCEMENT M20 M20/495 MIXING M20 M20/497 COLD WEATHER M20 M20/5 CEMENT/ SAND (AIR ENTRAINED) M20 M20/50 GYPSUM PLASTER SKIM COAT ON PLASTERBOARD M20 M20/510 SUITABILITY OF SUBSTRATES M20 M20/527 RAKING OUT FOR KEY M20 M20/531 ROUGHENING FOR KEY M20 M20/536 SPATTERDASH KEY M20 M20/538 STIPPLE KEY M20 M20/541 BONDING AGENT APPLICATION M20 M20/549 ZINC OXYCHLORIDE PLASTER M20 M20/551 REMOVAL AND RENEWAL OF EXISTING PLASTER/ RENDER M20 M20/556 REMOVING DEFECTIVE EXISTING RENDER M20 M20/566 REMOVING DEFECTIVE EXISTING PLASTER M20 M20/568 EXISTING DAMP AFFECTED PLASTER/ RENDER M20 M20/584 RECORD CASTINGS M20 M20/587 REPLACING TIMBER LATHS M20 M20/589 REFIXING SOUND TIMBER LATHS THROUGH PLASTER M20 M20/592 CONSOLIDATING EXISTING TIMBER LATH AND PLASTER CEILINGS M20 M20/60 CEMENTS FOR MORTARS M20 M20/600 ADDITIONAL FRAMING SUPPORTS FOR BACKINGS M20 M20/605 GYPSUM PLASTERBOARD BACKINGS M20 M20/607 PROPRIETARY GYPSUM PLASTERBOARD BACKINGS M20 M20/610 FIXING PLASTERBOARD BACKINGS TO TIMBER M20 M20/611 FIXING PLASTERBOARD BACKINGS M20 M20/612 JOINTS IN PLASTERBOARD BACKINGS M20 M20/62 ADMIXTURES FOR CEMENT GAUGED MORTARS M20 M20/624 DAMP PROOF LATHING M20 M20/626 TIMBER LATHING M20 M20/630 BEADS/ STOPS FOR INTERNAL USE M20 M20/634 BEADS/ STOPS M20 M20/636 BEADS/ STOPS FOR EXTERNAL USE M20 M20/638 ARCH FORM METAL LATHING M20 M20/640 BEADS/ STOPS GENERALLY M20 M20/646 CRACK CONTROL AT JUNCTIONS BETWEEN DISSIMILAR SOLID SUBSTRATES M20 M20/65 MIXING M20 M20/650 MOVEMENT JOINTS M20 M20/653 SEALANT MOVEMENT JOINTS WITH STOP BEAD EDGINGS M20 M20/659 PLASTERBOARD JOINTS M20 M20/67 COLD WEATHER M20 M20/673 PLASTERING OVER CONDUITS/ SERVICE CHASES M20 M20/680 FIBROUS PLASTER MOULDINGS M20 M20/685 SOLID CAST PLASTER M20 M20/689 IN SITU RUN PLASTER MOULDINGS M20 M20/692 REFIXING EXISTING PLASTER MOULDINGS M20 M20/695 REPRODUCTION OF EXISTING PLASTER MOULDINGS M20 M20/697 REPAIRING CRACKS/ STEPS IN PLASTER MOULDINGS M20 M20/699 REPAIRING HAND MODELLED PLASTERWORK M20 M20/71 SUITABILITY OF SUBSTRATES M20 M20/710 APPLICATION GENERALLY M20 M20/715 FLATNESS/ SURFACE REGULARITY M20 M20/718 JUNCTION OF NEW PLASTERWORK WITH EXISTING M20 M20/720 DUBBING OUT M20 M20/725 UNDERCOATS GENERALLY M20 M20/74 EXISTING DAMP AFFECTED PLASTER/ RENDER M20 M20/742 THIN COAT PLASTER M20 M20/747 PROJECTION PLASTER M20 M20/76 REMOVING DEFECTIVE EXISTING PLASTER M20 M20/777 SMOOTH FINISH M20 M20/778 WOOD FLOAT FINISH M20 M20/78 REMOVING DEFECTIVE EXISTING RENDER M20 M20/782 TEXTURED/ PATTERNED FINISHES M20 M20/786 PLASTERING ON TIMBER LATHING M20 M20/788 NONHYDRAULIC LIME PLASTER UNDERCOATS M20 M20/789 THREE LAYER NONHYDRAULIC LIME PLASTER FINAL COAT M20 M20/80 PLASTERBOARD BACKINGS M20 M20/810 APPLICATION GENERALLY M20 M20/815 FLATNESS/ SURFACE REGULARITY OF RENDERING TO RECEIVE CERAMIC TILES M20 M20/82 BEADS/ STOPS M20 M20/820 DUBBING OUT FOR RENDERING M20 M20/830 ANCHORED MESH REINFORCEMENT M20 M20/840 UNDERCOATS GENERALLY M20 M20/845 THROWN UNDERCOATS FOR LIME BASED ROUGHCAST (HARLING) M20 M20/85 DAMP PROOF LATHING M20 M20/856 FINAL COAT - PLAIN FLOATED FINISH M20 M20/861 FINAL COAT - SCRAPED FINISH M20 M20/866 FINAL COAT - ROUGHCAST (HARLING) FINISH M20 M20/87 APPLICATION OF COATINGS M20 M20/871 FINAL COAT - DRY DASH FINISH M20 M20/880 CURING AND DRYING M20 M20/885 CURING AND DRYING OF NONHYDRAULIC LIME RENDER M20 M20/93 CURING AND DRYING OF RENDER COATINGS M20 M20/95 RENDER FINAL COAT - DRY DASH M20 M20/97 RENDER FINAL COAT - SCRAPED FINISH M20 M20/99 RENDER FINAL COAT - PLAIN FLOATED FINISH M20 M21 INSULATION WITH RENDERED FINISH M M21/110 SURVEY OF STRUCTURAL SUBSTRATE M21 M21/120 SURVEY OF STRUCTURAL SUBSTRATE M21 M21/160 REMEDIAL WORK M21 M21/180 STRUCTURAL SUBSTRATE M21 M21/210 EXTERNAL WALL INSULATION SYSTEM M21 M21/220 EXTERNAL WALL INSULATION SYSTEM ON SUPPORT RAILS M21 M21/230 RENDERED EXTERNAL WALL INSULATION SYSTEM M21 M21/305 CONTRACTOR'S DESIGN M21 M21/307 COMPLETION OF DESIGN M21 M21/335 IMPACT RESISTANCE OF NON-LOADBEARING VERTICAL SURFACES M21 M21/360 SAMPLES M21 M21/380 UNIFORMITY OF COLOUR AND TEXTURE OF COATING MIXES M21 M21/410 INSTALLATION M21 M21/420 ADVERSE WEATHER M21 M21/430 SUBSTRATES M21 M21/440 ON SITE PULL OUT TESTS ON FIXING PINS M21 M21/490 CONSTRUCTION/ MOVEMENT JOINTS M21 M21/510 FIRE BARRIERS M21 M21/520 SUPPORTS FOR SERVICES/ FITTINGS M21 M21/530 SEALANT JOINTS M21 M21/550 INSPECTION OF COMPLETED INSTALLATION M21 M22 SPRAYED MONOLITHIC COATINGS M M22/110 SPRAYED M22 M22/120 SPRAYED M22 M22/130 EXTERNALLY SPRAYED M22 M22/160 RESISTANCE TO FIRE M22 M22/165 REACTION TO FIRE M22 M22/170 THERMAL TRANSMITTANCE (U-VALUE) M22 M22/180 ACOUSTIC PERFORMANCE M22 M22/210 SURFACES TO BE COATED M22 M22/220 ENVIRONMENTAL CONDITIONS M22 M22/240 SEQUENCE OF WORK M22 M22/250 DIFFICULT ACCESS AREAS M22 M22/260 PROTECTION FROM OVERSPRAY M22 M22/270 HEALTH AND SAFETY M22 M22/280 CONTROL SAMPLES M22 M22/290 INSPECTIONS M22 M22/300 FINISHED COATING APPEARANCE M22 M22/350 SPRAYED COATINGS GENERALLY M22 M22/380 CURING M22 M22/390 MOVEMENT JOINTS M22 M22/430 COMPLETION M22 M30 METAL LATHING/ ANCHORED MESH REINFORCEMENT FOR PLASTERED/ RENDERED COATINGS M M30/110 METAL LATH M30 M30/120 METAL LATH ON RUNNERS M30 M30/130 METAL LATH ON BEARERS AND RUNNERS M30 M30/140 METAL LATH ON HANGERS, BEARERS AND RUNNERS M30 M30/150 METAL LATH FOR CASINGS M30 M30/160 ANCHORED MESH REINFORCEMENT FOR RENDER WITH TILED FINISH M30 M30/170 METAL LATH ON SOLID SUBSTRATES M30 M30/215 METAL LATH M30 M30/225 WELDED MESH REINFORCEMENT M30 M30/235 WIRE M30 M30/245 SPIRAL WRAPPING AND STIRRUPS FOR CASINGS M30 M30/255 BANDING FOR CASINGS M30 M30/265 BUILDING PAPER M30 M30/275 ACCESS PANELS M30 M30/285 FIXINGS M30 M30/325 SUPPORTS M30 M30/335 FIXING SPIRAL WRAPPING FOR CASINGS M30 M30/345 FIXING STIRRUPS FOR CASINGS M30 M30/355 FIXING BANDING FOR CASINGS M30 M30/365 FURRINGS M30 M30/375 FIXING BUILDING PAPER M30 M30/385 LOCATING ACCESS PANELS M30 M30/395 FIXING METAL LATH M30 M30/410 FIXING EXPANDED METAL LATH M30 M30/420 FIXING RIBBED EXPANDED METAL LATH M30 M30/430 FIXING PAPER-BACKED WELDED WIRE LATH AND MESH M30 M30/450 FIXING ANCHORED MESH REINFORCEMENT M30 M30/460 FIXING METAL LATH ON SOLID SUBSTRATES M30 M40 STONE/ CONCRETE/ QUARRY/ CERAMIC TILING/ MOSAIC M M40/10 NATURAL STONE COVERING TO M40 M40/110 TILING TO M40 M40/115 NATURAL STONE COVERING TO M40 M40/12 MOSAIC TO M40 M40/120 MOSAIC TO M40 M40/130 FLOOR FINISH MATERIALS SPECIFICATION M40 M40/15 NEW BACKGROUNDS/BASES M40 M40/20 EXISTING BACKGROUNDS/BASES GENERALLY M40 M40/210 SUITABILITY OF BACKGROUNDS/ BASES M40 M40/215 FALLS IN THE BASES M40 M40/220 SWIMMING POOL TILING M40 M40/25 NEW PLASTER M40 M40/250 SAMPLES M40 M40/252 NATURAL STONE SAMPLES M40 M40/260 CONTROL SAMPLES M40 M40/27 INTERMEDIATE SUBSTRATE M40 M40/30 FIXING GENERALLY M40 M40/310 EXISTING BACKGROUNDS/BASES GENERALLY M40 M40/32 MORTAR BEDDING M40 M40/320 EXISTING CONCRETE/SCREEDS M40 M40/330 EXISTING PLASTER M40 M40/340 EXISTING GLAZED BRICK M40 M40/35 SETTING OUT M40 M40/350 EXISTING TILES M40 M40/355 OLD ADHESIVE RESIDUES ON CONCRETE/SCREED BASES M40 M40/360 EXISTING PAINT M40 M40/370 NEW IN SITU CONCRETE M40 M40/380 NEW PLASTER M40 M40/390 PLASTERBOARD BACKGROUNDS M40 M40/40 TILE SKIRTINGS M40 M40/400 BACKGROUNDS M40 M40/410 HACKING FOR KEY M40 M40/420 RAKING OUT FOR KEY M40 M40/430 SPATTERDASHING FOR KEY M40 M40/431 STIPPLING FOR KEY M40 M40/438 PREPARING CONCRETE BASES FOR FULLY BONDED BEDDING M40 M40/444 PREPARING CONCRETE BASES FOR PARTIALLY BONDED BEDDING M40 M40/450 PREPARING CONCRETE BASES FOR UNBONDED BEDDING - WITHOUT SEPARATING LAYER M40 M40/451 PREPARING CONCRETE BASES FOR UNBONDED BEDDING M40 M40/460 SMOOTHING UNDERLAYMENT M40 M40/470 INTERMEDIATE SUBSTRATE M40 M40/5 TILING TO M40 M40/50 ADHESIVE BED - NOTCHED TROWEL METHOD TO WALLS M40 M40/510 FIXING GENERALLY M40 M40/530 SETTING OUT M40 M40/540 LEVEL OF FLOOR TILING M40 M40/55 ADHESIVE BED - NOTCHED TROWEL AND BUTTERING METHOD TO WALLS M40 M40/550 FLATNESS/ REGULARITY OF TILING/ MOSAICS M40 M40/560 LEVEL OF TILING ACROSS JOINTS M40 M40/57 ADHESIVE BED - BUTTERING METHOD M40 M40/570 MORTAR BEDDING M40 M40/578 CRACK CONTROL REINFORCEMENT M40 M40/580 POROUS TILES M40 M40/590 COVED TILE SKIRTINGS M40 M40/60 ADHESIVE BED - NOTCHED TROWEL AND BUTTERING METHOD TO FLOORS M40 M40/600 SIT-ON TILE SKIRTINGS M40 M40/610 MULTISTOREY EXTERNAL TILING M40 M40/62 ADHESIVE BED - NOTCHED TROWEL METHOD FOR MESH BACKED MOSAIC TO WALLS M40 M40/64 ADHESIVE BED - NOTCHED TROWEL METHOD FOR PAPER FACED MOSAIC TO WALLS M40 M40/650 ADHESIVE BED - NOTCHED TROWEL METHOD (WALLS) M40 M40/651 ADHESIVE BED - NOTCHED TROWEL AND BUTTERING METHOD (WALLS) M40 M40/652 ADHESIVE BED - BUTTERING METHOD (WALLS) M40 M40/66 SEMIDRY CEMENT:SAND BEDDING (FLOORS) M40 M40/660 ADHESIVE BED - NOTCHED TROWEL METHOD FOR MESH BACKED MOSAIC (WALLS) M40 M40/661 ADHESIVE BED - NOTCHED TROWEL METHOD FOR PAPER FACED MOSAIC (WALLS) M40 M40/690 CEMENT:SAND MORTAR BEDDING (WALLS) M40 M40/70 GROUTING M40 M40/710 ADHESIVE BED - NOTCHED TROWEL AND BUTTERING METHOD (FLOORS) M40 M40/711 ADHESIVE BED - BUTTERING METHOD (FLOORS) M40 M40/720 CEMENT:SAND MORTAR BEDDING (FLOORS) M40 M40/730 SEMIDRY CEMENT:SAND BEDDING (FLOORS) M40 M40/740 CEMENT:LIME:SAND MORTAR BEDDING (FLOORS) M40 M40/75 SEALANT MOVEMENT JOINTS M40 M40/750 NATURAL HYDRAULIC LIME MORTAR BEDDING (FLOORS) M40 M40/80 STRIP MOVEMENT JOINTS M40 M40/805 SEALANT MOVEMENT JOINTS WITH METAL EDGINGS M40 M40/815 SEALANT MOVEMENT JOINTS M40 M40/825 STRIP MOVEMENT JOINTS M40 M40/835 METAL SECTION MOVEMENT JOINTS M40 M40/855 CEMENT:SAND GROUTING MIX M40 M40/865 CEMENT:LIME SAND GROUTING MIX M40 M40/875 GROUTING M40 M40/885 COLOURED GROUT M40 M40/900 TRL PENDULUM FLOOR COVERING SLIP RESISTANCE TESTING M40 M40/910 TRL PENDULUM FLOOR COVERING SLIP RESISTANCE TESTING M40 M40/920 SLIPSTD CLASS TESTING M40 M41 TERRAZZO TILING/ IN SITU TERRAZZO M M41/110 TERRAZZO TILING M41 M41/120 IN SITU TERRAZZO M41 M41/130 PRECAST TERRAZZO M41 M41/140 MARBLE TILING M41 M41/150 PLAIN IN SITU TERRAZZO SKIRTINGS M41 M41/155 COVED IN SITU TERRAZZO SKIRTINGS M41 M41/160 TERRAZZO TILE SKIRTINGS M41 M41/170 FLOOR FINISH MATERIALS SPECIFICATION M41 M41/210 SUITABILITY OF SUBSTRATES M41 M41/220 EXISTING CONCRETE/ SCREEDS M41 M41/230 SAMPLES M41 M41/235 CONTROL SAMPLES M41 M41/238 ANTISTATIC PERFORMANCE M41 M41/242 CEMENT M41 M41/245 SAND M41 M41/248 ADMIXTURES M41 M41/280 SEPARATING LAYER FOR UNBONDED BEDDING M41 M41/305 LAYING GENERALLY M41 M41/330 LEVEL OF FINISHED FLOOR M41 M41/340 FLATNESS/ SURFACE REGULARITY OF FINISHED FLOOR M41 M41/345 LEVEL OF UNGROUND TILING ACROSS JOINTS M41 M41/390 MIXING BEDDING MORTAR M41 M41/395 CRACK CONTROL REINFORCEMENT M41 M41/405 TILING ON MORTAR BEDDING M41 M41/430 IN SITU TERRAZZO M41 M41/440 DIVIDING STRIPS M41 M41/445 STRIP MOVEMENT JOINTS M41 M41/455 SEALANT MOVEMENT JOINTS WITH METAL EDGINGS M41 M41/465 METAL SECTION MOVEMENT JOINTS M41 M41/470 APPLIED SLIP RESISTANT M41 M41/520 GRINDING M41 M41/525 SLIP RESISTANCE TESTING M41 M41/532 TESTING ANTISTATIC FLOORING M41 M41/535 IDENTIFICATION PLATES FOR ANTISTATIC FLOORING M41 M41/540 CHEMICAL FLOOR HARDENER M41 M42 WOOD BLOCK/ COMPOSITION BLOCK/ MOSAIC PARQUET FLOORING M M42/105 WOOD FLOORING GENERALLY M42 M42/107 TIMBER PROCUREMENT M42 M42/110 WOOD BLOCK FLOORING M42 M42/120 MOSAIC PARQUET PANEL FLOORING M42 M42/150 COMPOSITION BLOCK FLOORING M42 M42/160 FLOOR FINISH MATERIALS SPECIFICATION M42 M42/210 DRYNESS OF CONCRETE/ SCREED SUBSTRATES M42 M42/220 CONCRETE/ SCREED SUBSTRATES M42 M42/230 EXISTING TIMBER SUBSTRATES M42 M42/250 HACKING FOR KEY M42 M42/260 BONDING TREATMENT FOR MORTAR BEDDING M42 M42/270 PLYWOOD UNDERLAY M42 M42/310 ENVIRONMENTAL CONDITIONS M42 M42/320 HEATING SYSTEM M42 M42/330 AIR CONDITIONING SYSTEM M42 M42/340 UNDERFLOOR HEATING M42 M42/350 PRODUCT SAMPLES M42 M42/380 ACCLIMATIZATION M42 M42/390 MOISTURE CONTENT TESTING M42 M42/410 SUITABILITY OF SUBSTRATE M42 M42/420 FIXTURES M42 M42/430 DRY LAYING M42 M42/440 SAMPLE AREA OF FLOORING M42 M42/450 APPEARANCE OF FINISHED FLOOR M42 M42/510 LAYING WOOD BLOCKS M42 M42/520 LAYING MOSAIC PARQUET PANELS M42 M42/550 MORTAR FOR BEDDING COMPOSITION BLOCKS M42 M42/560 ALLOWANCE FOR MOVEMENT M42 M42/570 DIVIDING/ DIMINISHING STRIPS M42 M42/575 APPLIED SLIP RESISTANT M42 M42/580 SANDING AND FILLING M42 M42/590 PROTECTION M42 M50 RUBBER/ PLASTICS/ CORK/ LINO/ CARPET TILING/ SHEETING M M50/110 TILING M50 M50/130 CARPET TILING M50 M50/138 NEEDLED CARPET TILING M50 M50/146 NEEDLED PILE CARPET TILING M50 M50/150 SHEETING M50 M50/155 PVC SHEET FLOORING IN SPECIAL WET AREAS M50 M50/170 CARPETING M50 M50/178 NEEDLED CARPETING M50 M50/186 NEEDLED PILE CARPETING M50 M50/190 STAIR COVERING SYSTEM M50 M50/195 FLOOR FINISH MATERIALS SPECIFICATION M50 M50/210 WORKMANSHIP GENERALLY M50 M50/220 SAMPLES M50 M50/230 CONTROL SAMPLES M50 M50/250 LAYOUT - ROLL MATERIALS M50 M50/251 LAYOUT - SEAMS IN ROLL MATERIALS M50 M50/252 LAYOUT - PATTERNS M50 M50/270 EXTRA MATERIAL M50 M50/330 COMMENCEMENT M50 M50/340 CONDITIONING M50 M50/350 ENVIRONMENT M50 M50/360 FLOORS WITH UNDERFLOOR HEATING M50 M50/410 NEW BASES M50 M50/420 EXISTING BASES M50 M50/430 NEW WET LAID BASES M50 M50/440 SUBSTRATES TO RECEIVE THIN COVERINGS M50 M50/460 SMOOTHING/ LEVELLING UNDERLAYMENT COMPOUND M50 M50/470 BASES FROM WHICH EXISTING FLOOR COVERINGS HAVE BEEN REMOVED M50 M50/480 EXISTING FLOOR COVERINGS TO BE OVERLAID M50 M50/510 WOOD BLOCK FLOORING M50 M50/520 TIMBER BOARDING/ STRIP FLOORING M50 M50/530 PARTICLEBOARD FLOORING M50 M50/535 PARTICLEBOARD FLOATING FLOORING M50 M50/550 HARDBOARD UNDERLAY M50 M50/560 PLYWOOD UNDERLAY M50 M50/610 SETTING OUT TILES M50 M50/620 COLOUR CONSISTENCY M50 M50/640 ADHESIVE FIXING GENERALLY M50 M50/650 SEAMS M50 M50/670 BORDERS/ AND FEATURE STRIPS IN SHEET MATERIAL M50 M50/680 SEAM WELDING COVERINGS M50 M50/690 SEAM BONDING CARPET M50 M50/700 LOOSE LAID CARPET TILES M50 M50/720 DOORWAYS M50 M50/740 EDGINGS AND COVER STRIPS M50 M50/750 STAIR NOSINGS AND TRIMS M50 M50/760 STAIR COVERINGS - SEPARATE RISERS AND TREADS M50 M50/770 SKIRTINGS M50 M50/780 TRAFFICKING AFTER LAYING M50 M50/820 FINISHING M50 M50/825 FINISHING NON-TEXTILE ANTISTATIC FLOORING M50 M50/830 FINISHING RUBBER FLOORING M50 M50/840 FINISHING RUBBER FLOORING - POLISH FINISH M50 M50/850 FINISHING CORK TILE FLOORING - POLISH FINISH M50 M50/851 FINISHING CORK TILE FLOORING - POLYURETHANE FINISH M50 M50/860 TESTING ANTISTATIC FLOORING M50 M50/861 SLIP RESISTANCE TESTING M50 M50/880 WASTE M50 M51 EDGE FIXED CARPETING M M51/110 CARPETING M51 M51/150 CARPETING FOR STAIRS M51 M51/160 FLOOR FINISH MATERIALS SPECIFICATION M51 M51/210 WORKMANSHIP GENERALLY M51 M51/220 SAMPLES M51 M51/230 CONTROL SAMPLES M51 M51/250 CARPET LAYOUT - PRE-ORDER REQUIREMENTS M51 M51/251 CARPET LAYOUT M51 M51/270 EXTRA MATERIAL M51 M51/290 CONDITIONING CARPET M51 M51/310 CONDITION OF WORKS PRIOR TO LAYING M51 M51/315 NOTIFICATION OF COMMENCEMENT M51 M51/320 ENVIRONMENT M51 M51/330 SUITABILITY OF BASES M51 M51/340 NEW WET LAID BASES M51 M51/350 TIMBER BOARDING/ STRIP FLOORING M51 M51/360 EXISTING FLOOR COVERINGS TO BE OVERLAID M51 M51/370 HARDBOARD UNDERLAY M51 M51/371 PLYWOOD UNDERLAY M51 M51/410 CARPET GRIPPER M51 M51/420 INTERLAY M51 M51/430 UNDERLAY ON FLOORS M51 M51/440 UNDERLAY ON STAIRS M51 M51/450 CARPET SEAMS/ JOINTS M51 M51/460 RAW EDGE SEAMS (INCLUDING CROSS SEAMS) M51 M51/470 LAYING CARPET GENERALLY M51 M51/480 POWER STRETCHING M51 M51/490 DOORWAYS M51 M51/510 EDGINGS AND COVER STRIPS M51 M51/530 LAYING STAIR CARPET WITH GRIPPER M51 M51/540 LAYING STAIR CARPET WITH ADHESIVE M51 M51/550 STAIR NOSINGS AND TRIMS M51 M51/570 COMPLETION M51 M51/580 WASTE M51 M52 DECORATIVE PAPERS/ FABRICS M M52/110 COVERING FOR M52 M52/220 SAMPLES M52 M52/225 WALLPAPER GENERALLY M52 M52/230 EXTRA MATERIAL M52 M52/241 ENVIRONMENT M52 M52/251 CONDITIONING M52 M52/310 PREPARATION GENERALLY M52 M52/330 FIXTURES AND FITTINGS M52 M52/340 COATED SUBSTRATES M52 M52/350 PAPER/ FABRIC COVERED SUBSTRATES M52 M52/360 VINYL COVERED SUBSTRATES M52 M52/370 ORGANIC GROWTHS M52 M52/380 SIZE/ SEALER M52 M52/420 HANGING GENERALLY M52 M52/450 SETTING OUT M52 M52/480 LININGS M52 M52/490 COVERINGS M52 M52/500 JOINTS IN COVERINGS M52 M52/520 SHADING M52 M52/530 PATTERN M52 M60 PAINTING/CLEAR FINISHING M M60/10 EMULSION PAINT M60 M60/110 EMULSION PAINT M60 M60/12 GLOSS PAINT M60 M60/130 GLOSS PAINT M60 M60/14 EGGSHELL/ SATIN PAINT M60 M60/150 EGGSHELL/ SATIN PAINT M60 M60/16 DECORATIVE WOODSTAIN/ VARNISH/ PRESERVATIVE M60 M60/160 DECORATIVE WOODSTAIN/ VARNISH/ PRESERVATIVE M60 M60/165 MULTICOLOURED COATING M60 M60/170 MASONRY COATING M60 M60/175 PROTECTIVE COATING M60 M60/18 SPECIAL COATING M60 M60/180 FLOOR COATING M60 M60/185 FAUX FINISH/ COATING M60 M60/190 OIL GILDING M60 M60/195 SPECIAL COATING M60 M60/20 COATING MATERIALS M60 M60/210 COATING MATERIALS M60 M60/215 HANDLING AND STORAGE M60 M60/220 COMPATIBILITY M60 M60/240 SURFACES NOT TO BE COATED M60 M60/25 SURFACES NOT TO BE COATED M60 M60/250 SURFACES TO BE CLEANED BUT NOT COATED M60 M60/26 SURFACES TO BE CLEANED BUT NOT COATED M60 M60/280 PROTECTION M60 M60/30 PREPARATION GENERALLY M60 M60/300 CONTROL SAMPLES M60 M60/310 SUPERVISED CONTROL SAMPLES M60 M60/32 PREVIOUSLY COATED SURFACES GENERALLY M60 M60/320 INSPECTION BY COATING MANUFACTURERS M60 M60/321 INSPECTION OF WORK STAGES M60 M60/35 FIXTURES AND FITTINGS M60 M60/37 WOOD PREPARATION M60 M60/39 STEEL PREPARATION M60 M60/400 PREPARATION GENERALLY M60 M60/41 MASONRY AND RENDERING PREPARATION M60 M60/420 FIXTURES AND FITTINGS M60 M60/425 IRONMONGERY M60 M60/43 PLASTER PREPARATION M60 M60/430 EXISTING IRONMONGERY M60 M60/440 PREVIOUSLY COATED SURFACES GENERALLY M60 M60/45 PREVIOUSLY PAINTED WINDOW FRAMES M60 M60/451 PREVIOUSLY COATED SURFACES - BLAST CLEANING M60 M60/456 PREVIOUSLY COATED SURFACE - BURNING OFF M60 M60/461 PREVIOUSLY COATED WOOD M60 M60/471 PREPRIMED WOOD M60 M60/481 UNCOATED WOOD M60 M60/490 PREVIOUSLY COATED STEEL M60 M60/50 EXTERNAL POINTING TO EXISTING FRAMES M60 M60/500 PREPRIMED STEEL M60 M60/511 GALVANIZED, SHERARDIZED AND ELECTROPLATED STEEL M60 M60/52 SEALING OF INTERNAL MOVEMENT JOINTS M60 M60/521 UNCOATED STEEL - MANUAL CLEANING M60 M60/531 UNCOATED STEEL - BLAST CLEANING M60 M60/541 UNCOATED ALUMINIUM/ COPPER/ LEAD M60 M60/55 EXISTING GUTTERS M60 M60/552 UNCOATED PVC-U M60 M60/560 UNCOATED CONCRETE M60 M60/570 UNCOATED MASONRY/ RENDERING M60 M60/580 UNCOATED PLASTER M60 M60/590 UNCOATED PLASTERBOARD M60 M60/601 UNCOATED PLASTERBOARD - TO RECEIVE TEXTURED COATING M60 M60/61 COATING GENERALLY M60 M60/611 WALL COVERINGS M60 M60/622 ORGANIC GROWTHS M60 M60/631 PREVIOUSLY PAINTED WINDOWS FRAMES M60 M60/640 EXTERNAL POINTING TO EXISTING FRAMES M60 M60/645 SEALING OF INTERNAL MOVEMENT JOINTS M60 M60/65 CONCEALED JOINERY SURFACES M60 M60/651 EXISTING GUTTERS M60 M60/66 CONCEALED METAL SURFACES M60 M60/68 STAINING WOOD M60 M60/70 EXTERNAL DOORS M60 M60/711 COATING GENERALLY M60 M60/720 PRIMING JOINERY M60 M60/730 WORKSHOP COATING OF CONCEALED JOINERY SURFACES M60 M60/731 SITE COATING OF CONCEALED JOINERY SURFACES M60 M60/740 CONCEALED METAL SURFACES M60 M60/75 BEAD GLAZING TO COATED WOOD M60 M60/751 STAINING WOOD M60 M60/760 VARNISHING WOOD M60 M60/770 EXTERNAL DOORS M60 M60/780 BEAD GLAZING TO COATED WOOD M60 M60/790 PUTTY GLAZING M60 M60/80 PUTTY GLAZING M60 M60/800 GLAZING M60 M60/810 WATER REPELLENT M60 M61 INTUMESCENT COATINGS FOR FIRE PROTECTION OF STEELWORK M M61/110 ON SITE COATING TO PRIMED STEEL M61 M61/115 ON SITE COATING TO GALVANIZED STEEL M61 M61/120 ON SITE COATING TO EXISTING STEEL M61 M61/140 ON SITE OVERCOATING TO EXISTING STEEL M61 M61/145 SITE APPLIED INTUMESCENT CASTINGS M61 M61/150 OFF SITE COATING TO UNPRIMED STEEL M61 M61/160 OFF SITE COATING TO PRIMED STEEL M61 M61/170 OFF SITE COATING TO GALVANIZED STEEL M61 M61/205 VALIDATION OF MATERIALS M61 M61/210 WORKING PROCEDURES M61 M61/215 WORKING CONDITIONS M61 M61/220 APPLICATOR'S PERSONNEL M61 M61/250 SPRAYED COATING APPLICATION M61 M61/260 CONTROL SAMPLES M61 M61/270 INSPECTION M61 M61/280 OFF SITE COATED STEEL M61 M61/315 NEW STEEL - BLAST CLEANING M61 M61/320 EXISTING STEEL - BLAST CLEANING M61 M61/330 EXISTING STEEL - MANUAL CLEANING M61 M61/340 EXISTING STEEL - OVERCOATING M61 M61/410 INTUMESCENT DRY FILM THICKNESS (DFT) M61 M61/420 MEASUREMENT OF INTUMESCENT DFT M61 M61/440 BASIC FINISH M61 M61/450 NORMAL DECORATIVE FINISH M61 M61/460 HIGH DECORATIVE FINISH M61 M61/490 TOP SEALER COAT M61 M61/520 COMPLETION OF OFF SITE COATED STEEL M61 M61/530 RECORDS OF COATED STEEL M61 N FURNITURE/ EQUIPMENT N10 GENERAL FIXTURES/ FURNISHINGS/ EQUIPMENT N N10/110 PURPOSE MADE N10 N10/125 DESKS AND TABLES N10 N10/130 LABORATORY FURNITURE N10 N10/135 STORAGE AND DISPLAY UNITS N10 N10/145 VANITY AND WASHROOM FURNITURE N10 N10/160 SHELVING SYSTEM N10 N10/170 BENCHES AND LINKED SEATS N10 N10/171 FIXED SEATING N10 N10/172 RETRACTABLE/ DEMOUNTABLE SEATING SYSTEM N10 N10/173 STACKING CHAIR SYSTEMS N10 N10/177 CHAIRS N10 N10/178 DEMOUNTABLE PODIA AND STAGING N10 N10/180 FREESTANDING SCREENS N10 N10/184 WALL RAILS N10 N10/188 BATHROOM AND WASHROOM EQUIPMENT N10 N10/190 CAGES N10 N10/192 CHALKBOARDS N10 N10/193 WHITEBOARDS N10 N10/195 NOTICEBOARDS N10 N10/200 WORKTOPS N10 N10/210 COAT RACKS N10 N10/220 LOCKERS N10 N10/230 CURTAIN N10 N10/235 CURTAINS N10 N10/240 BLINDS N10 N10/242 BLINDS N10 N10/245 VENETIAN BLINDS N10 N10/250 TELEPHONE BOOTHS N10 N10/270 MIRRORS N10 N10/290 MATWELL FRAMES N10 N10/300 ENTRANCE MATTING N10 N10/310 LOOSE LAID MATTING N10 N10/330 FIREPLACES N10 N10/350 MISCELLANEOUS FITTINGS N10 N10/410 SOLID FUEL ROOM HEATERS N10 N10/415 WOOD BURNING ROOM HEATERS N10 N10/440 INSET OPEN FIRES N10 N10/450 INSET OPEN FIRES WITH CONVECTION N10 N10/460 SEALANT N10 N10/710 MOISTURE CONTENT OF WOOD AND WOOD BASED BOARDS N10 N10/720 INSTALLATION GENERALLY N10 N10/760 SEALANT BEDDING AND POINTING N10 N10/770 TRIMS N10 N10/910 GENERAL N10 N10/920 APPLIANCES N10 N11 DOMESTIC KITCHEN FITTINGS, FURNISHINGS AND EQUIPMENT N N11/310 FITTED BASE UNITS N11 N11/320 FITTED WALL UNITS N11 N11/330 ISLAND AND PENINSULA KITCHEN UNITS N11 N11/340 WORKTOPS N11 N11/350 SINKS, TAPS, TRAPS AND WASTES N11 N11/360 APPLIANCES N11 N11/370 SHELVING N11 N11/380 PURPOSE MADE UNITS N11 N11/390 SEALANT N11 N11/610 MOISTURE CONTENT OF WOOD AND WOOD BASED BOARDS N11 N11/620 INSTALLATION GENERALLY N11 N11/630 INSTALLING UNITS AND WORKTOPS N11 N11/640 INSTALLING APPLIANCES N11 N11/650 INSTALLING SINKS, TAPS AND WASTES N11 N11/660 SEALANT BEDDING AND POINTING N11 N11/670 INSTALLING TRIMS AND MOULDINGS N11 N11/910 GENERAL N11 N11/920 APPLIANCE COMMISSIONING N11 N12 COMMERCIAL CATERING FITTINGS, FURNISHINGS AND EQUIPMENT N N12/310 FOOD PREPARATION N12 N12/320 WORKTOPS N12 N12/330 COOKING EQUIPMENT N12 N12/340 APPLIANCES N12 N12/350 HOT CUPBOARDS N12 N12/360 SERVERY COUNTERS N12 N12/370 DISPLAY UNITS N12 N12/380 SINKS, TAPS, TRAPS AND WASTES N12 N12/390 FOOD WASTE DISPOSAL UNIT N12 N12/400 DISHWASHING MACHINE N12 N12/410 REFRIGERATION AND FREEZER UNITS N12 N12/420 CUPBOARDS AND STORAGE UNITS N12 N12/430 SHELVING N12 N12/440 PURPOSE MADE N12 N12/450 LOOSE LAID MATTING N12 N12/460 MISCELLANEOUS EQUIPMENT N12 N12/470 SEALANT N12 N12/610 MOISTURE CONTENT OF WOOD AND WOOD BASED BOARDS N12 N12/620 INSTALLATION GENERALLY N12 N12/630 INSTALLING EQUIPMENT, UNITS, APPLIANCES AND WORKTOPS N12 N12/640 SERVICES TO EQUIPMENT, UNITS AND APPLIANCES N12 N12/650 INSTALLING SINKS, TAPS, TRAPS AND WASTES N12 N12/660 SEALANT BEDDING AND POINTING N12 N12/670 TRIMS N12 N12/910 GENERAL N12 N12/920 EQUIPMENT, UNITS AND APPLIANCES N12 N13 SANITARY APPLIANCES AND FITTINGS N N13/300 WCS AND CISTERNS N13 N13/302 WCS AND FLUSHING VALVES N13 N13/304 WASH/ DRY WCS N13 N13/305 COMPOSTING TOILETS N13 N13/311 UNISEX ACCESSIBLE CORNER WC EQUIPMENT PACKAGES (DOCUMENT M) N13 N13/315 URINALS AND AUTO FLUSHING CISTERNS N13 N13/316 URINALS AND FLUSHING VALVES N13 N13/321 URINALS - WATERLESS N13 N13/325 BIDETS N13 N13/331 SINKS N13 N13/335 WASH BASINS N13 N13/341 VANITY TOPS WITH FORMED WASH BASINS N13 N13/343 PROPRIETARY FULLY FINISHED VANITY UNITS N13 N13/346 WASHING TROUGHS N13 N13/351 WASH FOUNTAINS N13 N13/355 BATHS N13 N13/358 ASSISTED ACCESS BATHS N13 N13/361 WHIRLPOOL BATHS N13 N13/365 SAUNAS N13 N13/369 STEAM ROOMS N13 N13/375 SHOWER UNITS N13 N13/379 DRINKING FOUNTAINS N13 N13/382 SLOP HOPPERS N13 N13/384 BEDPAN WASHERS N13 N13/386 DISPOSAL UNITS N13 N13/388 COMBINED SLOP HOPPERS AND SINKS N13 N13/389 COMBINED BEDPAN WASHERS AND SINKS N13 N13/392 COMBINED WC AND WASHBASIN UNITS N13 N13/420 PROXIMITY SENSOR CONTROL UNITS N13 N13/422 AIR FRESHENERS N13 N13/424 ASHTRAYS N13 N13/426 BACKRESTS N13 N13/428 BOTTLE OPENERS N13 N13/429 CLOTHES HOOKS N13 N13/432 CLOTHES LINES N13 N13/434 FACIAL TISSUE DISPENSERS N13 N13/436 HANDRAILS AND GRAB BARS N13 N13/438 MIRRORS N13 N13/440 NEEDLE DISPOSAL BOXES N13 N13/441 PAPER ROLL DISPENSERS N13 N13/442 PAPER TOWEL DISPENSERS N13 N13/444 SANITARY INCINERATORS AND MACERATORS N13 N13/446 SANITARY TOWEL DISPOSAL BINS N13 N13/448 SEATS N13 N13/449 SHELVES N13 N13/452 SMALL BORE MACERATOR AND PUMPING UNITS N13 N13/454 SMALL BORE PUMPING UNITS N13 N13/456 SOAP DISHES N13 N13/458 SOAP DISPENSERS N13 N13/460 TOILET BRUSH HOLDERS N13 N13/462 TOILET PAPER HOLDERS N13 N13/464 TOOTHBRUSH HOLDERS N13 N13/466 TOWEL RAILS N13 N13/468 TOWEL RINGS N13 N13/470 TUMBLER HOLDERS N13 N13/472 HAND DRIERS N13 N13/474 WASTE BINS N13 N13/476 WASTE PIPE PROTECTORS N13 N13/478 DISPOSABLE APRON DISPENSERS N13 N13/480 DISPOSABLE GLOVES DISPENSERS N13 N13/482 HAND CLEANSING GEL DISPENSERS N13 N13/484 SANITARY TOWEL DISPENSERS N13 N13/486 SURFACE WIPES DISPENSERS N13 N13/488 CHANGING BENCHES N13 N13/490 HOIST SYSTEMS N13 N13/492 PRIVACY CURTAINS N13 N13/500 PREPLUMBED FRAME SYSTEM N13 N13/580 SEALANT FOR POINTING N13 N13/610 INSTALLATION GENERALLY N13 N13/613 COMPATIBILITY OF COMPONENTS N13 N13/620 NOGGINGS AND BEARERS N13 N13/630 TILED BACKGROUNDS OTHER THAN SPLASHBACKS N13 N13/650 INSTALLING WC PANS N13 N13/655 INSTALLING COMPOSTING TOILETS N13 N13/660 INSTALLING SLAB URINALS N13 N13/670 INSTALLING CISTERNS N13 N13/710 INSTALLING TAPS N13 N13/720 INSTALLING WASTES AND OVERFLOWS N13 N13/725 INSTALLING HAND DRIERS N13 N13/755 SEALANT BEDDING AND POINTING N13 N14 GENERAL INTERNAL SIGNAGE SYSTEMS N N14/110 SIGNAGE SYSTEM N14 N14/120 INCLUSIVE SIGNAGE SYSTEMS N14 N14/210 GENERAL REQUIREMENTS N14 N14/240 FIRE REACTION N14 N14/280 DESIGN LIFE N14 N14/290 SIGNAGE SAMPLES N14 N14/295 SIGNAGE SAMPLES BOARD N14 N14/305 PRODUCTS GENERALLY N14 N14/310 ADHESIVE VINYL N14 N14/320 ALUMINIUM N14 N14/330 BRASS N14 N14/340 GLASS N14 N14/350 PLASTICS N14 N14/360 STAINLESS STEEL N14 N14/370 STOVE ENAMELLED METAL PLATE N14 N14/380 WOOD N14 N14/610 FIXING SIGNS GENERALLY N14 N14/620 FIXING SIGNS FOR THE VISUALLY IMPAIRED N14 N14/670 ELECTRICAL AND DATA SERVICES N14 N14/710 IN SITU SIGNS N14 N14/910 DOCUMENTATION N14 N14/920 SPARES N14 N14/930 SPECIALIST TOOLS N14 N15 INTERNAL FIRE AND SAFETY SIGNAGE SYSTEMS N N15/110 FIRE SIGNAGE SYSTEMS N15 N15/120 SAFETY SIGNAGE SYSTEMS N15 N15/210 GENERAL REQUIREMENTS N15 N15/240 SIGNAGE SYSTEM SPECIFICATION N15 N15/270 FIRE REACTION N15 N15/280 DESIGN LIFE N15 N15/290 SIGNAGE SAMPLES N15 N15/305 INTERNAL SIGNAGE PRODUCTS GENERALLY N15 N15/310 ADHESIVE VINYL SHEET N15 N15/320 ALUMINIUM PLATE N15 N15/330 PLASTICS SHEET N15 N15/340 STAINLESS STEEL PLATE N15 N15/350 STOVE ENAMELLED METAL PLATE N15 N15/400 PHOTOLUMINESCENT SIGNS N15 N15/410 SELF-LUMINOUS SIGNS N15 N15/610 FIXING SIGNS GENERALLY N15 N15/910 DOCUMENTATION N15 N15/920 SPARES N15 N15/930 SPECIALIST TOOLS N15 N16 BIRD AND VERMIN CONTROL SYSTEMS N N16/110 BIRD CONTROL N16 N16/120 RODENT CONTROL N16 N16/130 INSECT CONTROL N16 N16/210 GENERAL REQUIREMENTS N16 N16/310 GUARDS N16 N16/320 MESH SCREENS N16 N16/330 NET BARRIERS N16 N16/340 ROOST INHIBITORS N16 N16/350 TRAPS N16 N16/360 BIRD SCARING DEVICES N16 N16/370 POWERED DEVICES N16 N16/380 DETERRENT COATINGS N16 N16/400 SEALANT N16 N16/505 FABRICATION GENERALLY N16 N16/510 COLUMBARY N16 N16/610 WORKMANSHIP GENERALLY N16 N16/620 DECONTAMINATION N16 N16/640 CONCRETE FOUNDATIONS GENERALLY N16 N16/645 SETTING COMPONENTS IN CONCRETE N16 N16/920 BUILDING MANAGEMENT SYSTEM (BMS) COMPATIBILITY N16 N16/940 DOCUMENTATION N16 N17 PORTABLE FIRE FIGHTING SYSTEMS N N17/110 PORTABLE FIRE EXTINGUISHER SYSTEM N17 N17/150 FIRE BLANKET SYSTEM N17 N17/160 FIRE BUCKET SYSTEM N17 N17/210 DESIGN N17 N17/220 COLOUR CODING N17 N17/310 CARBON DIOXIDE EXTINGUISHERS N17 N17/320 DRY POWDER EXTINGUISHERS N17 N17/330 FOAM EXTINGUISHERS N17 N17/340 WATER EXTINGUISHERS N17 N17/350 WET CHEMICAL EXTINGUISHERS N17 N17/410 FIRE BLANKETS - LIGHT DUTY N17 N17/420 FIRE BLANKETS - HEAVY DUTY N17 N17/450 FIRE BUCKETS N17 N17/610 INSTALLING PORTABLE FIRE EXTINGUISHERS N17 N17/650 INSTALLING FIRE BLANKETS N17 N17/670 INSTALLING FIRE BUCKETS N17 N17/910 CLEANING N17 N17/920 TESTING N17 N17/930 TRAINING N17 N17/940 MAINTENANCE N17 N25 PERMANENT ACCESS AND SAFETY EQUIPMENT N N25/110 PERMANENT SUSPENDED ACCESS SYSTEM N25 N25/115 LATERAL RESTRAINT SYSTEM FOR SUSPENDED CRADLE N25 N25/120 ROBOTIC CLEANING SYSTEM N25 N25/130 GANTRY ACCESS SYSTEM N25 N25/140 TRAVELLING LADDER N25 N25/210 GUIDED TYPE FALL ARREST SYSTEM N25 N25/220 SINGLE POINT ANCHORAGE DEVICES N25 N25/250 SAFETY NET N25 N25/260 MATERIAL/ PROTECTION NET N25 N25/410 WIND LOADING IN ACCORDANCE WITH BS 6399-2 N25 N25/415 WIND LOADING TO BS EN 1991-1-4 N25 N25/420 WIND LOADING FROM EXISTING DATA N25 N25/430 SAFETY N25 N25/440 DESIGN LIFE/ MAINTENANCE PROGRAMME N25 N25/450 TESTING OF PERMANENT SUSPENDED ACCESS EQUIPMENT N25 N25/460 ASSESSMENT/ TESTING OF FIXING POINTS FOR ANCHOR DEVICES N25 N25/510 FABRICATION AND ASSEMBLY GENERALLY N25 N25/520 PROTECTION N25 N25/530 SUITABILITY OF STRUCTURE/ FABRIC N25 N25/535 EXECUTION GENERALLY N25 N25/540 MECHANICAL FIXINGS N25 N25/550 FASTENERS, INSERTS AND BOLTS FOR BUILDING IN N25 N25/560 FIXINGS FOR SECURING EQUIPMENT N25 N25/570 FIXING ANCHOR INSTALLATION N25 N25/605 IDENTIFICATION AND REGISTRATION LABELS FOR SUSPENDED ACCESS SYSTEM N25 N25/610 IDENTIFICATION AND REGISTRATION LABELS FOR OTHER EQUIPMENT N25 N25/615 CE MARKING AND DECLARATION OF CONFORMITY OF PERMANENTLY INSTALLED SUSPENDED ACCESS EQUIPMENT N25 N25/630 LIFTING EQUIPMENT CONFIGURATION N25 N25/640 MARKING OF ANCHOR DEVICES N25 N25/710 ELECTRICAL INSTALLATION N25 N25/810 SERVICE/ MAINTENANCE N25 N25/820 OPERATING INSTRUCTIONS N25 N25/830 OPERATING AND MAINTENANCE MANUAL N25 N25/840 AS INSTALLED DRAWINGS N25 N91 EXTERNAL SIGNAGE AND INTERPRETATION N N91/110 PROPRIETARY SIGNAGE SYSTEM N91 N91/120 BESPOKE SIGNAGE SYSTEM N91 N91/205 DESIGN OF SIGNAGE SYSTEMS N91 N91/210 EXTERNAL SIGNAGE GENERALLY N91 N91/215 DESIGN LIFE N91 N91/220 SAFETY SIGNAGE REQUIREMENTS N91 N91/225 ROAD TRAFFIC SIGNAGE REQUIREMENTS N91 N91/230 ACCESSIBILITY N91 N91/235 ELECTRICAL REQUIREMENTS FOR ILLUMINATED SIGNS N91 N91/305 SIGNAGE PRODUCTS GENERALLY N91 N91/310 POSTS FOR EXTERNAL SIGNS N91 N91/315 POSTS FOR ROAD TRAFFIC SIGNS N91 N91/320 LOCKING MECHANISMS N91 N91/325 BRAILLE N91 N91/330 TACTILE SYMBOLS N91 N91/335 AUDIBLE CONTENT/ INTERACTIVE SOUND SYSTEM N91 N91/340 TOUCH-SCREEN TECHNOLOGY N91 N91/405 ADHESIVE VINYL N91 N91/410 ALUMINIUM N91 N91/415 BRASS N91 N91/420 BRONZE N91 N91/425 CARBON STEEL N91 N91/430 CAST IRON N91 N91/435 GLASS N91 N91/440 GLAZING PLASTICS N91 N91/445 PLASTICS AND COMPOSITE MATERIALS N91 N91/450 PLYWOOD N91 N91/455 STAINLESS STEEL N91 N91/460 STOVE-PLATED ENAMEL N91 N91/465 VITREOUS ENAMEL N91 N91/470 WOOD N91 N91/475 FABRICS FOR BANNERS N91 N91/480 ZINC N91 N91/505 SIGNAGE SAMPLES N91 N91/510 SAFETY SIGN N91 N91/515 ROAD TRAFFIC SIGN N91 N91/520 MONOLITH/ ENTRANCE/ WELCOME SIGN N91 N91/525 POST-MOUNTED SIGN N91 N91/530 LOCKABLE NOTICEBOARD/ DISPLAY CABINET N91 N91/535 LADDER SIGN N91 N91/540 LECTERN PANEL N91 N91/545 'A' BOARD N91 N91/550 FINGER POST N91 N91/555 WAYMARKER POST/ BOLLARD N91 N91/560 BANNER SIGN N91 N91/565 PLAQUE/ WALL-MOUNTED SIGN N91 N91/570 WAYMARKER DISC N91 N91/575 LETTERS N91 N91/580 EXTERNAL SIGN N91 N91/605 METHOD OF FIXING SIGNS N91 N91/610 FIXING SIGNS GENERALLY N91 N91/615 BUILDING SIGNS INTO EXISTING STRUCTURES N91 N91/620 FIXING ROAD SIGNS N91 N91/625 FIXING SIGN POSTS INTO CONCRETE N91 N91/630 SETTING EXTERNAL POSTS INTO EXISTING CONCRETE STRUCTURES N91 N91/635 POSTS SET IN EARTH N91 N91/640 CARVING/ SANDBLASTING/ PAINTING IN/ ON STONE/ MASONRY/ WOOD N91 N91/645 SITE-MADE SIGN - PAINTED OR CARVED N91 N91/650 ROUTING IN WOOD N91 N91/655 WORKMANSHIP FOR GLAZING GENERALLY N91 N91/660 SITE PAINTING AND STAINING N91 N91/665 MAKING GOOD GALVANIZED SURFACES N91 N91/670 MAKING GOOD TREATED WOOD N91 N91/675 ELECTRICAL AND DATA SERVICES N91 N91/905 INSPECTION OF SIGNS N91 N91/910 TESTING OF SIGNS AND STRUCTURES N91 N91/915 CLEANING OF SIGNS/ GRAFFITI REMOVAL N91 N91/920 DOCUMENTATION N91 N91/925 SPARE PARTS N91 N91/930 SPECIALIST TOOLS N91 P BUILDING FABRIC SUNDRIES P10 SUNDRY INSULATION/ PROOFING WORK P P10/110 EAVES ROOF VENTILATORS FOR EXISTING ROOFS P10 P10/125 INSULATION LAID BETWEEN CEILING TIES/ JOISTS P10 P10/135 INSULATION LAID ACROSS CEILING TIES/ JOISTS P10 P10/140 INSULATION FITTED BETWEEN RAFTERS P10 P10/147 POLYURETHANE FOAM SPRAYED BETWEEN RAFTERS P10 P10/148 INSULATION FIXED UNDER RAFTERS P10 P10/149 INSULATION FIXED ABOVE RAFTERS P10 P10/150 BLOWN LOFT INSULATION P10 P10/160 LOOSE LAID LOFT INSULATION P10 P10/165 INSULATION TO EAVES P10 P10/170 INSULATION TO LOFT ACCESS HATCHES P10 P10/180 INSULATION TO WATER CISTERNS P10 P10/185 SOFFIT INSULATION P10 P10/190 INSULATION FITTED BETWEEN STUDS P10 P10/200 INSULATION BLOWN BETWEEN STUDS P10 P10/205 INSULATION SPRAYED BETWEEN STUDS P10 P10/212 INSULATION FIXED ACROSS INNER FACE OF STUD WALLING P10 P10/217 INSULATION SLABS FIXED TO BACKING WALL P10 P10/220 SOUND INSULATION WITHIN TIMBER FRAMED SEPARATING WALL P10 P10/240 INSULATION FITTED BETWEEN FLOOR JOISTS P10 P10/250 INSULATION SUPPORTED BETWEEN FLOOR JOISTS P10 P10/260 ABSORBENT PUGGING P10 P10/270 HEAVY PUGGING P10 P10/310 VAPOUR CONTROL LAYER P10 P10/320 BREATHER MEMBRANE P10 P10/410 FLEXIBLE CAVITY BARRIERS P10 P10/420 SLEEVED MINERAL WOOL SMALL CAVITY BARRIERS P10 P10/430 WIRED MINERAL WOOL SMALL CAVITY BARRIERS P10 P10/432 CAVITY BARRIERS P10 P10/435 VENTILATED CAVITY BARRIERS P10 P10/440 FIRE PROTECTION P10 P11 FOAMED/ FIBRE/ BEAD CAVITY WALL INSULATION P P11/110 PRECONTRACT SURVEY OF EXISTING WALLS P11 P11/130 SURVEY OF EXISTING WALLS P11 P11/140 REMEDIAL WORK TO EXISTING WALLS P11 P11/170 SUITABILITY OF WALLS P11 P11/210 UREA-FORMALDAHYDE FOAM CAVITY FILL P11 P11/220 PROPRIETARY CAVITY FILL P11 P11/230 CAVITY FILL P11 P11/240 POLYURETHANE FOAM CAVITY WALL STABILISATION AND INSULATION SYSTEM P11 P11/310 GAPS AND OPENINGS P11 P11/320 INJECTION HOLES P11 P11/330 MAKING GOOD P11 P11/340 FLUES WITH NO APPLIANCE P11 P11/350 FLUES WITH AN APPLIANCE FITTED P11 P11/360 RECORDS P11 P11/365 THERMOGRAPHIC INTEGRITY TEST P11 P11/370 DOCUMENTATION P11 P12 FIRE STOPPING SYSTEMS P P12/110 FIRE STOPPING SYSTEM P12 P12/130 FIRE STOPPING SYSTEM TO INDIVIDUAL SERVICES PENETRATIONS P12 P12/140 FIRE STOPPING SYSTEM TO MULTIPLE SERVICES PENETRATIONS P12 P12/150 LOOSE FIRE STOPPING P12 P12/160 LINEAR GAP SEALING P12 P12/210 DESIGN P12 P12/240 FIRE PERFORMANCE P12 P12/260 DESIGN LIFE P12 P12/305 PRODUCT CERTIFICATION P12 P12/310 BOARDS - CALCIUM SILICATE FIBRE REINFORCED P12 P12/315 BOARDS - CALCIUM SILICATE FILLED AND FIBRE REINFORCED P12 P12/320 BOARDS - EXFOLIATED VERMICULITE P12 P12/325 BOARDS - MINERAL BOUND LIGHTWEIGHT P12 P12/330 FIRE STOP LAMINATE P12 P12/335 INTUMESCENT FOAM P12 P12/338 INTUMESCENT MASTIC P12 P12/340 INTUMESCENT MORTAR P12 P12/342 FIRE RESISTING MORTAR P12 P12/345 INTUMESCENT PILLOWS P12 P12/350 INTUMESCENT PUTTY P12 P12/360 MINERAL WOOL RIGID BATTS P12 P12/365 MINERAL WOOL RIGID BATTS – ABLATIVE COATED P12 P12/370 PIPE COLLAR – CONCEALED INTUMESCENT P12 P12/375 PIPE COLLAR – INSULATED WRAP P12 P12/380 PIPE COLLAR – SURFACE MOUNTED INTUMESCENT P12 P12/385 SEALANT BACKING MATERIAL P12 P12/390 SEALANT - FIRE RESISTING SILICONE P12 P12/395 SEALANT - ONE-PART FIRE RESISTING ACRYLIC P12 P12/410 SEALANT - TWO-PART FIRE RESISTING POLYSULFIDE P12 P12/620 WORKMANSHIP GENERALLY P12 P12/640 INSTALLING BOARDING P12 P12/650 INSTALLING FIRE STOP LAMINATE P12 P12/660 INSTALLING INTUMESCENT FOAM P12 P12/670 APPLYING INTUMESCENT MORTAR P12 P12/680 INSTALLING INTUMESCENT PILLOWS P12 P12/690 APPLYING INTUMESCENT PUTTY P12 P12/710 INSTALLING MINERAL WOOL BATTS P12 P12/730 FIXING INTUMESCENT PIPE COLLARS P12 P12/740 INSERTING SEALANT BACKING MATERIAL P12 P12/745 APPLYING SEALANTS GENERALLY P12 P12/750 APPLYING CAPPING SEALANT P12 P12/910 CLEANING P12 P12/920 INSPECTION P12 P20 UNFRAMED ISOLATED TRIMS/ SKIRTINGS/ SUNDRY ITEMS P P20/110 SOFTWOOD P20 P20/120 HARDWOOD P20 P20/150 METAL P20 P20/170 PROPRIETARY P20 P20/200 MEDIUM DENSITY FIBREBOARD P20 P20/240 PLYWOOD P20 P20/250 PARTICLEBOARD P20 P20/260 WOOD VENEERED P20 P20/270 PLASTICS VENEERED BOARD P20 P20/280 PLASTICS VENEERED P20 P20/315 HARDBOARD P20 P20/350 PINBOARDS P20 P20/360 PINBOARD P20 P20/410 LEG SUPPORTS P20 P20/415 LEG SUPPORTS P20 P20/420 BRACKET SUPPORTS P20 P20/425 BRACKET SUPPORTS P20 P20/440 DECORATIVE FACING P20 P20/450 PROPRIETARY P20 P20/510 INSTALLATION GENERALLY P20 P21 DOOR/ WINDOW IRONMONGERY P P21/10 QUANTITIES AND LOCATIONS P21 P21/120 IRONMONGERY RANGE SELECTED BY CONTRACTOR P21 P21/121 IRONMONGERY FROM SINGLE PROPRIETARY RANGE P21 P21/122 IRONMONGERY FROM LISTED PROPRIETARY RANGES P21 P21/130 APPROVED SUPPLIERS P21 P21/140 SAMPLES P21 P21/141 SAMPLE BOARDS P21 P21/170 IRONMONGERY FOR FIRE DOORS P21 P21/180 CATEGORY OF DUTY FOR DOOR IRONMONGERY P21 P21/310 SINGLE AXIS DOOR HINGES P21 P21/315 PERFORMANCE SPECIFICATION FOR SINGLE AXIS DOOR HINGES P21 P21/320 DOOR HINGES P21 P21/350 DOOR TRACK AND RUNNING GEAR P21 P21/360 PERFORMANCE SPECIFICATION FOR DOOR TRACK AND RUNNING GEAR P21 P21/365 SINGLE AXIS WINDOW HINGES P21 P21/370 WINDOW HINGES P21 P21/380 SLIDING FRICTION STAY HINGES P21 P21/385 PIVOT HINGES P21 P21/390 SPIRAL SASH BALANCES P21 P21/395 BOXED SASH HANGING FITTINGS P21 P21/410 OVERHEAD DOOR CLOSERS P21 P21/412 PERFORMANCE SPECIFICATION FOR OVERHEAD DOOR CLOSERS P21 P21/450 FLOOR SPRINGS P21 P21/452 PERFORMANCE SPECIFICATION FOR FLOOR SPRINGS P21 P21/471 ELECTROMAGNETIC HOLD OPEN/ SWING-FREE DEVICES (24 V) P21 P21/472 PERFORMANCE SPECIFICATION FOR ELECTROMAGNETIC HOLD OPEN/ SWING-FREE DEVICES (24 V) P21 P21/481 DOOR COORDINATORS P21 P21/482 PERFORMANCE SPECIFICATION FOR DOOR COORDINATORS P21 P21/490 UNCONTROLLED DOOR CLOSERS P21 P21/510 THIEF RESISTANT DOOR LOCKS P21 P21/515 DOOR LOCKS P21 P21/525 PERFORMANCE SPECIFICATION FOR DOOR LOCKS AND LATCHES P21 P21/530 SPECIAL FUNCTION DOOR LOCKS P21 P21/540 DOOR LATCHES P21 P21/565 PADLOCKS P21 P21/566 PERFORMANCE SPECIFICATION FOR PADLOCKS P21 P21/571 EMERGENCY EXIT DEVICES P21 P21/572 PERFORMANCE SPECIFICATION FOR EMERGENCY EXIT DEVICES P21 P21/577 PANIC EXIT DEVICES P21 P21/578 PERFORMANCE SPECIFICATION FOR PANIC EXIT DEVICES P21 P21/582 DOOR BOLTS P21 P21/584 PERFORMANCE SPECIFICATION FOR DOOR BOLTS P21 P21/586 PRIVACY INDICATOR BOLTS P21 P21/590 WINDOW ESPAGNOLETTE BOLTS P21 P21/592 SASH FASTENERS P21 P21/593 SASH SCREWS P21 P21/594 FANLIGHT CATCHES P21 P21/596 CASEMENT/ SASH MORTICE BOLTS P21 P21/610 LEVER HANDLES P21 P21/620 DOOR KNOBS P21 P21/622 PERFORMANCE SPECIFICATION FOR LEVER HANDLE SETS P21 P21/625 PERFORMANCE SPECIFICATION FOR KNOBSETS P21 P21/641 PULL HANDLES P21 P21/651 PERFORMANCE SPECIFICATION FOR PULL HANDLES P21 P21/670 PUSH PLATES P21 P21/680 MIDRAIL PLATES P21 P21/690 KICK PLATES P21 P21/710 ESCUTCHEONS P21 P21/720 DOOR STOPS P21 P21/730 LETTER PLATES P21 P21/731 PERFORMANCE SPECIFICATION FOR LETTER PLATES P21 P21/735 INTERNAL LETTER FLAPS P21 P21/750 LIMITING DOOR STAYS P21 P21/760 DOOR HOLDERS P21 P21/770 PADLOCK HASP AND STAPLE P21 P21/811 DOOR MOUNTED COAT HOOKS P21 P21/850 THRESHOLD WEATHERSTRIP P21 P21/855 WEATHERSTRIP TO DOOR HEAD AND JAMBS P21 P21/860 SEALS FOR P21 P21/890 DOOR VIEWERS P21 P21/895 DOOR MOUNTED AIR TRANSFER GRILLES P21 P21/896 DOOR MOUNTED FIRE RESISTING AIR TRANSFER GRILLES P21 P21/897 DOOR MOUNTED FIRE RESISTING AIR TRANSFER GRILLES WITH SMOKE SHUTTER P21 P21/900 CASEMENT HANDLES P21 P21/905 CASEMENT STAYS P21 P21/910 WINDOW LEVER HANDLES P21 P21/925 OVER CENTRE CASEMENT STAYS P21 P21/930 FRICTION RESTRICTOR CASEMENT STAYS P21 P21/935 REMOTE WINDOW OPENERS P21 P21/940 SASH LIFT HANDLES P21 P21/950 SASH EYES P21 P21/960 WEATHERSTRIP TO WINDOWS P21 P30 TRENCHES, PIPEWAYS AND PITS FOR BURIED ENGINEERING SERVICES P P30/140 BURIED ENGINEERING SERVICES SYSTEMS P30 P30/150 ACCESS AND INSPECTION CHAMBER SYSTEMS P30 P30/210 DESIGN P30 P30/301 ACCESS COVERS/ MANHOLE TOPS AND FRAMES P30 P30/305 PROPRIETARY ACCESS AND INSPECTION CHAMBERS P30 P30/320 PIPEDUCTS P30 P30/335 SMALL SURFACE BOXES P30 P30/340 SMALL SURFACE ACCESS POINTS P30 P30/345 LARGE SURFACE BOXES TO BS 5834-2 P30 P30/350 LARGE SURFACE BOXES AND ACCESS COVERS TO BS EN 124 P30 P30/355 LARGE SURFACE BOXES FOR FIRE HYDRANTS TO BS 750 OR BS 5834-2 P30 P30/411 SELECTED AS-DUG MATERIAL P30 P30/412 GRANULAR MATERIAL P30 P30/415 CONCRETE - PRECAST P30 P30/440 MORTAR BEDDING P30 P30/470 FOAMED CONCRETE FOR BACKFILLING P30 P30/475 DRAWLINES P30 P30/480 WARNING MARKER TAPES P30 P30/490 WARNING MARKER TILES P30 P30/495 WARNING MARKER BOARDS P30 P30/610 ROUTES OF SERVICES BELOW GROUND P30 P30/620 EXISTING ROADS AND PAVINGS P30 P30/625 TRENCHES P30 P30/630 CUTTING TREE ROOTS IN SERVICE TRENCHES P30 P30/640 LAYING PIPEDUCTS P30 P30/645 PIPEDUCT BEDDING AND SURROUND - SELECTED AS-DUG MATERIAL P30 P30/650 PIPEDUCT BEDDING AND SURROUND - GRANULAR MATERIAL P30 P30/655 CONCRETE SURROUND FOR PIPEDUCTS P30 P30/660 CONCRETE SURROUND FOR SHALLOW PIPEDUCTS UNDER BUILDINGS P30 P30/665 PIPEDUCT RUNS NEAR FOUNDATIONS P30 P30/668 INSTALLING PROPRIETARY ACCESS AND INSPECTION CHAMBERS AND SURFACE BOXES P30 P30/670 BEDDING OF FRAMES FOR ACCESS COVERS AND SURFACE BOXES P30 P30/675 BACKFILLING GENERALLY P30 P30/680 BACKFILLING UNDER ROADS AND PAVINGS P30 P30/700 BACKFILLING WITH FOAMED CONCRETE P30 P30/710 TEMPORARY BRIDGES P30 P30/720 WARNING MARKER BOARDS, TAPES AND TILES P30 P30/750 ADDITIONAL REQUIREMENTS FOR WATER AND GAS MAINS P30 P30/910 INSPECTION P30 P30/920 TESTING P30 P30/930 DOCUMENTATION P30 P31 HOLES, CHASES, COVERS AND SUPPORTS FOR SERVICES P P31/300 FLOOR DUCTING/ TRUNKING P31 P31/370 ACCESS COVERS/ GRATINGS FOR P31 P31/400 METER CABINETS P31 P31/610 COORDINATION P31 P31/620 HOLES AND CHASES IN SITU CONCRETE P31 P31/630 HOLES AND CHASES IN PRECAST CONCRETE P31 P31/640 HOLES IN STRUCTURAL STEELWORK P31 P31/650 HOLES, RECESSES AND CHASES IN MASONRY P31 P31/660 PREFORMED HOLES IN MASONRY P31 P31/670 NOTCHES AND HOLES IN STRUCTURAL TIMBER P31 P31/680 FIXING FLOOR DUCTING/ TRUNKING P31 P31/690 INSTALLING PIPE SLEEVES P31 P31/710 SEALING P31 P31/730 INSTALLING ACCESS COVERS/ GRATINGS AND FRAMES P31 P31/740 INSTALLING METER CABINETS P31 P32 SERVICES PAINTING SYSTEMS P P32/110 WALL COATING P32 P32/120 FLOOR, BUND AND PLINTH COATING P32 P32/130 METAL SURFACE COATING P32 P32/210 DESIGN P32 P32/220 DESIGN LIFE P32 P32/310 COATING RANGE P32 P32/312 SEALANT, WATER BASED ACRYLIC P32 P32/315 UNDERCOAT, THINNED WATER BASED P32 P32/320 BASECOAT P32 P32/330 PRIMER P32 P32/340 BITUMEN BASED COATING P32 P32/350 WATER BASED FINISHING COAT P32 P32/370 SOLVENT BASED FINISHING COAT P32 P32/380 TAR BASED BLACK PAINT P32 P32/610 PREPARATION GENERALLY P32 P32/635 SERVICE EQUIPMENT, FIXTURES AND FITTINGS P32 P32/645 PREPARING PREVIOUSLY COATED SURFACES P32 P32/655 PREPARING PREVIOUSLY COATED STEEL P32 P32/665 PREPARING UNCOATED STEEL - MANUAL CLEANING P32 P32/680 PREPARING UNCOATED ALUMINIUM OR COPPER OR LEAD P32 P32/705 PREPARING UNCOATED MASONRY AND/ OR RENDERING P32 P32/710 PREPARING UNCOATED PLASTER P32 P32/715 PREPARING UNCOATED PLASTERBOARD P32 P32/730 PREPARING AND DEALING WITH ORGANIC GROWTHS P32 P32/740 PREPARING AND APPLYING SEALANTS P32 P32/760 APPLYING COATINGS GENERALLY P32 P32/770 COATING CONCEALED METAL SURFACES P32 P32/910 REMOVED ITEMS P32 P32/920 DOCUMENTATION P32 P32/930 SPARES AND CONSUMABLES P32 P33 PLINTHS AND BUND SYSTEMS P P33/110 PLINTH SYSTEM P33 P33/140 BUND SYSTEM P33 P33/210 DESIGN P33 P33/230 BUNDS PERFORMANCE P33 P33/240 PERMISSIBLE SERVICE LOADS P33 P33/250 EXCEPTIONAL LOADS P33 P33/310 BLOCK MASONRY P33 P33/320 BRICK MASONRY P33 P33/330 CONCRETE - PRE-CAST PANELS P33 P33/340 CONCRETE - READY-MIX P33 P33/350 GRP PROFILED PANELS P33 P33/360 PRESSED STEEL PANELS P33 P33/370 STEEL - LARGE SECTIONS P33 P33/380 STEEL - LIGHT SECTIONS P33 P33/390 CONCRETE REINFORCEMENT P33 P33/400 DAMP-PROOF COURSES P33 P33/410 MASONRY BED JOINT REINFORCEMENT P33 P33/420 MASONRY REINFORCEMENT - VERTICAL P33 P33/430 READY-MIX MASONRY MORTAR P33 P33/440 SITE MIX MASONRY MORTAR P33 P33/450 PRESSED STEEL CAPPINGS P33 P33/460 RENDER COATINGS P33 P33/470 INSULATION P33 P33/480 RENDER STOPS P33 P33/510 PREFABRICATED FRAMES P33 P33/630 MASONRY P33 P33/670 MIXING SITE MIX MASONRY MORTAR P33 P33/680 PLACING REINFORCEMENT P33 P33/685 CONSTRUCTING FORMWORK P33 P33/690 CONCRETING P33 P33/700 RENDERING P33 P33/740 EXECUTION OF STEELWORK P33 P33/910 CLEANING BUND P33 P33/920 BUND TESTING P33 P33/930 INSPECTION P33 P33/940 DOCUMENTATION P33 Q PAVING/PLANTING/FENCING/SITE FURNITURE Q05 BIODIVERSITY AND ENVIRONMENTAL CONSERVATION Q Q05/110 HABITAT CREATION Q05 Q05/120 HABITAT MANAGEMENT AND ENHANCEMENT Q05 Q05/130 HABITAT PROTECTION Q05 Q05/140 SPECIES INTRODUCTION Q05 Q05/150 SPECIES PROTECTION Q05 Q05/220 HABITAT PROTECTION Q05 Q05/230 UK BIODIVERSITY ACTION PLAN (UK BAP) HABITATS Q05 Q05/240 SPECIES PROTECTION Q05 Q05/250 UK BIODIVERSITY ACTION PLAN (UK BAP) PRIORITY SPECIES Q05 Q05/260 BREEDING SITES Q05 Q05/310 SOURCE OF LIVING MATERIAL Q05 Q05/610 TIMING OF OPERATIONS ON-SITE Q05 Q05/910 ECOLOGICAL MONITORING SURVEY Q05 Q05/920 INVASIVE SPECIES MONITORING SURVEY Q05 Q05/930 REPORTS GENERALLY Q05 Q05/940 ECOLOGICAL SURVEY REPORT Q05 Q05/950 INVASIVE SPECIES SURVEY REPORT Q05 Q05/960 ENVIRONMENTAL MANAGEMENT PLANS Q05 Q10 KERBS/ EDGINGS/ CHANNELS/ PAVING ACCESSORIES Q Q10/110 PROPRIETARY PRECAST CONCRETE Q10 Q10/112 PRECAST CONCRETE Q10 Q10/115 PRECAST CONCRETE SAFETY KERBS Q10 Q10/120 STONE Q10 Q10/125 RECLAIMED STONE Q10 Q10/130 CLAY BRICK Q10 Q10/150 CONCRETE BLOCK Q10 Q10/170 LINEAR SLOT DRAINAGE CHANNEL SYSTEMS Q10 Q10/180 DRAINAGE CHANNEL SYSTEMS WITH GRATINGS Q10 Q10/185 FILTRATION DRAINAGE CHANNELS Q10 Q10/190 CARRIAGEWAY KERB AND DRAINAGE CHANNEL SYSTEMS Q10 Q10/200 SPECIAL Q10 Q10/250 MATERIAL SAMPLES Q10 Q10/305 TREE GRILLES Q10 Q10/310 CATTLE GRIDS Q10 Q10/312 FOOTWAY GRATINGS Q10 Q10/315 TRAFFIC CALMING HUMPS Q10 Q10/325 TRAFFIC CALMING SPEED CUSHIONS Q10 Q10/390 ROAD MARKING (LIGHT DUTY) Q10 Q10/395 ROAD MARKING (THERMOPLASTIC) Q10 Q10/400 RETROREFLECTING ROAD STUDS Q10 Q10/410 APPLIED SLIP RESISTANT Q10 Q10/510 LAYING KERBS, EDGINGS AND CHANNELS Q10 Q10/520 ADVERSE WEATHER Q10 Q10/530 CONCRETE FOR FOUNDATIONS, RACES AND HAUNCHING Q10 Q10/540 CEMENT MORTAR BEDDING Q10 Q10/543 LIME MORTAR BEDDING Q10 Q10/545 PROPRIETARY BEDDING Q10 Q10/547 BEDDING/BACKING OF UNITS ON FRESH CONCRETE RACES Q10 Q10/550 KERB DOWELS Q10 Q10/560 HAUNCHING DOWELS Q10 Q10/570 CHANNELS Q10 Q10/580 DRAINAGE CHANNEL SYSTEMS Q10 Q10/590 DRAINAGE CHANNEL SYSTEMS WITH BUILT IN FALL Q10 Q10/600 RADIUS KERBS/CHANNELS Q10 Q10/610 ANGLE KERBS Q10 Q10/620 ACCURACY Q10 Q10/625 REGULARITY OF PAVED SURFACES Q10 Q10/630 NARROW MORTAR JOINTS Q10 Q10/640 TOOLED MORTAR JOINTS Q10 Q10/641 TOOLED COLOURED MORTAR JOINTS Q10 Q10/650 SEALANT MOVEMENT JOINTS Q10 Q20 GRANULAR SUB-BASES TO ROADS/ PAVINGS Q Q20/110 THICKNESSES OF SUB-BASE/ SUBGRADE IMPROVEMENT LAYERS Q20 Q20/120 CHECKING OF SUBGRADES Q20 Q20/130 HERBICIDES Q20 Q20/140 EXCAVATION OF SUBGRADES Q20 Q20/145 PREPARATION AND COMPACTION OF SUBGRADES Q20 Q20/150 SUBGRADES FOR VEHICULAR AREAS Q20 Q20/170 GEOTEXTILE FILTER/ SEPARATOR MEMBRANE Q20 Q20/175 IMPERMEABLE MEMBRANE Q20 Q20/180 NOTICE Q20 Q20/200 SUBGRADE IMPROVEMENT LAYER (CAPPING) Q20 Q20/205 HIGHWAYS AGENCY TYPE 2 UNBOUND MIXTURE FOR SUB-BASE Q20 Q20/210 HIGHWAYS AGENCY TYPE 1 UNBOUND MIXTURE FOR SUB-BASE Q20 Q20/211 GRANULAR MATERIAL Q20 Q20/213 BLINDING PROTECTION FOR MEMBRANES Q20 Q20/215 COARSE GRADED AGGREGATE FOR PERMEABLE PAVING Q20 Q20/217 ADDITIONAL REQUIREMENTS FOR HYDRAULICALLY BOUND COARSE GRADED AGGREGATE FOR PERMEABLE PAVING Q20 Q20/220 FROST SUSCEPTIBLE GRANULAR MATERIAL Q20 Q20/225 PLACING OF MATERIAL WITH HIGH SULFATE CONTENT Q20 Q20/230 PLACING GRANULAR MATERIAL GENERALLY Q20 Q20/240 LAYING GRANULAR SUB-BASES FOR VEHICULAR AREAS Q20 Q20/241 LAYING GRANULAR SUB-BASES FOR VEHICULAR AREAS Q20 Q20/250 LAYING GRANULAR SUB-BASES Q20 Q20/310 ACCURACY Q20 Q20/315 ACCURACY FOR SUB-BASES TO SPORTS SURFACING Q20 Q20/320 SURFACES TO RECEIVE SAND BEDDING FOR PAVING Q20 Q20/330 COLD WEATHER WORKING Q20 Q20/340 PROTECTION Q20 Q21 IN SITU CONCRETE ROADS/ PAVINGS/ BASES Q Q21/110 UNREINFORCED PAVING (DESIGNATED CONCRETE) Q21 Q21/115 PAVING WITH EMBEDDED METAL (DESIGNATED CONCRETE) Q21 Q21/117 UNREINFORCED PAVING (DESIGNED CONCRETE) Q21 Q21/118 PAVING WITH EMBEDDED METAL (DESIGNED CONCRETE) Q21 Q21/120 SITE MIXED UNREINFORCED CONCRETE PAVING Q21 Q21/125 IN SITU CONCRETE AND GRASS PAVING SYSTEM Q21 Q21/130 HARD LANDSCAPING MATERIALS SPECIFICATION Q21 Q21/140 READY-MIXED CONCRETE Q21 Q21/141 SITE MIXED CONCRETE Q21 Q21/142 RECYCLED AGGREGATE Q21 Q21/145 ADMIXTURES Q21 Q21/150 REINFORCEMENT Q21 Q21/152 PROPRIETARY STEEL FIBRES Q21 Q21/153 STEEL FIBRES Q21 Q21/154 POLYMER FIBRES Q21 Q21/155 PROJECT TESTING OF CONCRETE - GENERAL Q21 Q21/160 INITIAL PROJECT TESTING OF CONCRETE Q21 Q21/165 REGULAR PROJECT TESTING OF CONCRETE Q21 Q21/240 SUB-BASE PREPARATION Q21 Q21/250 LAYING FABRIC REINFORCEMENT Q21 Q21/260 STEEL FORMWORK Q21 Q21/265 TIMBER PERMANENT FORMWORK Q21 Q21/310 TRANSPORTING CONCRETE Q21 Q21/320 LAYING CONCRETE GENERALLY Q21 Q21/330 COMPACTING Q21 Q21/340 MANHOLE COVER AND GULLY GRATING FRAMES Q21 Q21/350 LEVELS Q21 Q21/360 SURFACE REGULARITY Q21 Q21/370 ACCURACY FOR BASES BENEATH SPORTS SURFACING Q21 Q21/380 QUALITY CONTROL Q21 Q21/410 JOINTS GENERALLY Q21 Q21/420 TIE BARS Q21 Q21/430 DOWEL BARS Q21 Q21/440 LONGITUDINAL CONSTRUCTION JOINTS Q21 Q21/450 CONTRACTION JOINTS WITH SAWN GROOVE Q21 Q21/460 CONTRACTION JOINTS WITH WET FORMED GROOVE Q21 Q21/470 EXPANSION JOINTS Q21 Q21/510 SAMPLE AREA Q21 Q21/515 EXISTING SAMPLE AREA Q21 Q21/520 TAMPED FINISH Q21 Q21/530 BRUSHED FINISH Q21 Q21/540 SMOOTH FLOATED FINISH Q21 Q21/550 POWER TROWEL FINISH Q21 Q21/560 IMPRINTED PATTERN FINISH Q21 Q21/570 WASH AND BRUSH FINISH Q21 Q21/580 POWER GROUND FINISH Q21 Q21/590 ABRASIVE BLASTED FINISH Q21 Q21/610 CURING Q21 Q21/615 CURING PERIODS Q21 Q21/620 CHEMICAL STAINING Q21 Q21/630 SURFACE SEALER Q21 Q21/640 HOT JOINT SEALING Q21 Q21/650 COLD JOINT SEALING Q21 Q21/660 PROTECTION Q21 Q21/670 OPENING TO TRAFFIC Q21 Q22 ASPHALT ROADS/ PAVINGS Q Q22/110 ASPHALT CONCRETE PAVING Q22 Q22/115 ASPHALT CONCRETE PAVING Q22 Q22/127 PERMEABLE ASPHALT CONCRETE PAVING Q22 Q22/140 HOT ROLLED ASPHALT PAVING Q22 Q22/150 LIGHT DUTY MASTIC ASPHALT PAVING Q22 Q22/154 HOT ROLLED ASPHALT PAVING Q22 Q22/160 STONE MASTIC ASPHALT PAVING Q22 Q22/170 PROPRIETARY VEHICULAR PAVING Q22 Q22/175 PROPRIETARY PEDESTRIAN PAVING Q22 Q22/180 SURFACE TREATMENT TO EXISTING PAVING Q22 Q22/185 PROPRIETARY SURFACE TREATMENT TO EXISTING PAVING Q22 Q22/190 APPLIED SLIP RESISTANT Q22 Q22/195 HARD LANDSCAPING MATERIALS SPECIFICATION Q22 Q22/210 TIMBER EDGING Q22 Q22/220 BITUMINOUS MATERIALS GENERALLY Q22 Q22/230 SAMPLES Q22 Q22/240 ACCEPTANCE OF SURFACES Q22 Q22/250 ABUTMENTS Q22 Q22/310 LAYING GENERALLY Q22 Q22/320 ADVERSE WEATHER Q22 Q22/330 LEVELS Q22 Q22/340 FLATNESS/ SURFACE REGULARITY Q22 Q22/345 ACCURACY FOR BASES BENEATH SPORTS SURFACING Q22 Q22/350 CONTRACTOR'S USE OF PAVEMENTS Q22 Q22/351 CONTRACTOR'S USE OF PAVEMENTS Q22 Q22/360 UNCOATED CHIPPINGS FOR SURFACE TREATMENT Q22 Q22/365 PROPRIETARY SURFACE TREATMENT Q22 Q22/370 COATED CHIPPINGS Q22 Q22/390 DOCUMENTATION Q22 Q23 GRAVEL/ HOGGIN/ WOODCHIP/ RESIN BOUND ROADS/ PAVINGS/ OVERLAYS Q Q23/110 HARD BINDING GRAVEL Q23 Q23/120 BLINDED GRAVEL Q23 Q23/130 FINE HOGGIN Q23 Q23/140 SURFACING FOR CYCLE TRACKS Q23 Q23/150 LOOSE LAID CHIPPINGS Q23 Q23/160 LOOSE GRAVEL Q23 Q23/170 LOOSE GRAVEL OVERLAY Q23 Q23/180 BONDED CHIPPINGS FOR VEHICULAR AREAS Q23 Q23/190 BONDED CHIPPINGS FOR PEDESTRIAN AREAS Q23 Q23/220 TWO COAT PROPRIETARY FIBRE REINFORCED BONDED CHIPPINGS Q23 Q23/221 PROPRIETARY FIBRE REINFORCED BONDED CHIPPINGS OVERLAY Q23 Q23/225 PROPRIETARY RESIN BONDED CHIPPINGS Q23 Q23/226 PROPRIETARY RESIN BONDED CHIPPINGS OVERLAY Q23 Q23/227 PROPRIETARY SLURRY SURFACING OVERLAY Q23 Q23/230 WOODCHIP SURFACES Q23 Q23/235 WOODFIBRE SURFACES Q23 Q23/240 WOODCHIP AND STONE TRIM TRAILS Q23 Q23/250 MULTI-PURPOSE EQUESTRIAN SURFACING Q23 Q23/260 SAFETY EQUESTRIAN SURFACING Q23 Q23/270 HARD LANDSCAPING MATERIALS SPECIFICATION Q23 Q23/310 TIMBER EDGING Q23 Q23/315 MATERIALS Q23 Q23/320 SAMPLES Q23 Q23/325 BLINDING TO SUB-BASE Q23 Q23/330 HERBICIDE TO PAVING Q23/ Q23 Q23/340 LAYING GENERALLY Q23 Q23/350 COLD WEATHER WORKING Q23 Q23/360 DRAINAGE FALLS Q23 Q23/370 LAYING GRANULAR SURFACES IN VEHICULAR AREAS Q23 Q23/380 LAYING GRANULAR SURFACES IN PEDESTRIAN AREAS Q23 Q23/390 PROTECTION FROM TRAFFIC AND PLANT Q23 Q24 INTERLOCKING BRICK/ BLOCK ROADS/ PAVINGS Q Q24/110 CONVENTIONAL CONCRETE BLOCK PAVING Q24 Q24/112 CONVENTIONAL CONCRETE BLOCK PAVING WITH BOUND BASE Q24 Q24/113 CONVENTIONAL CONCRETE BLOCK PAVING OVERLAY Q24 Q24/115 PERMEABLE CONCRETE BLOCK PAVING - TOTAL INFILTRATION Q24 Q24/117 PERMEABLE CONCRETE BLOCK PAVING - PARTIAL INFILTRATION Q24 Q24/119 PERMEABLE CONCRETE BLOCK PAVING - NO INFILTRATION Q24 Q24/120 CONVENTIONAL CLAY PAVER PAVING Q24 Q24/122 CONVENTIONAL CLAY PAVER PAVING WITH BOUND BASE Q24 Q24/123 CONVENTIONAL CLAY PAVER PAVING OVERLAY Q24 Q24/124 PERMEABLE CLAY PAVER PAVING - TOTAL INFILTRATION Q24 Q24/126 PERMEABLE CLAY PAVER PAVING - PARTIAL INFILTRATION Q24 Q24/128 PERMEABLE CLAY PAVER PAVING - NO INFILTRATION Q24 Q24/130 NATURAL STONE SETT PAVING Q24 Q24/132 NATURAL STONE SETT PAVING WITH BOUND BASE Q24 Q24/133 NATURAL STONE SETT PAVING OVERLAY Q24 Q24/150 APPLIED SLIP RESISTANT Q24 Q24/160 HARD LANDSCAPING MATERIALS SPECIFICATION Q24 Q24/200 EXECUTION GENERALLY - CONCRETE BLOCK AND CLAY PAVER PAVING Q24 Q24/205 EXECUTION GENERALLY - NATURAL STONE PAVING Q24 Q24/211 COLOUR BANDING Q24 Q24/220 SAMPLES Q24 Q24/230 CONTROL SAMPLES Q24 Q24/240 ADVERSE WEATHER Q24 Q24/325 DRAINAGE HOLES IN EXISTING BASES Q24 Q24/335 PLANING AND REPAIRS TO EXISTING BASES Q24 Q24/350 GRANULAR LAYER OVER EXISTING BASES Q24 Q24/385 MORTAR BEDDED Q24 Q24/420 TOOLED JOINTS IN MORTAR BEDDED UNITS Q24 Q24/425 TOOLED COLOURED JOINTS IN MORTAR BEDDED UNITS Q24 Q24/430 SEALANT MOVEMENT JOINTS IN MORTAR BEDDED UNITS Q24 Q24/440 LAYING GEOTEXTILE EDGING STRIP FOR CONVENTIONAL PAVING Q24 Q24/445 LAYING GEOTEXTILE PATCHES OVER DRAINAGE HOLES FOR CONVENTIONAL PAVING Q24 Q24/450 LAYING GEOTEXTILE SHEET FOR CONVENTIONAL PAVING Q24 Q24/451 LAYING GEOTEXTILE SHEET FOR PERMEABLE PAVING Q24 Q24/452 PREPARED EXISTING AND NEW BOUND BASES (ROADBASES) Q24 Q24/485 LAYING BLOCKS/ PAVERS/ SETTS Q24 Q24/490 LAYING PERMEABLE PAVING Q24 Q24/495 IN SITU SURROUNDS TO OBSTRUCTIONS Q24 Q24/500 REGULARITY OF PAVED SURFACES Q24 Q24/505 REGULARITY OF PAVED SURFACES Q24 Q24/600 SEALER/ STABILIZER FOR NEW BLOCKS AND SETTS Q24 Q24/605 CLEANING/ SEALER/ STABILIZER FOR EXISTING BLOCKS AND SETTS Q24 Q24/610 GUN APPLIED JOINT SEALER Q24 Q24/615 COMPLETION OF PAVING Q24 Q25 SLAB/ BRICK/ SETT/ COBBLE PAVINGS Q Q25/110 NATURAL STONE SLAB PAVING SYSTEM Q25 Q25/115 NATURAL STONE SLAB PAVING OVERLAY SYSTEM Q25 Q25/120 CONCRETE FLAG PAVING SYSTEM Q25 Q25/125 CONCRETE FLAG PAVING OVERLAY SYSTEM Q25 Q25/127 PEDESTAL SUPPORTED PAVING SLAB/ FLAG SYSTEM Q25 Q25/130 RIGID BRICK PAVING SYSTEM Q25 Q25/135 RIGID BRICK PAVING OVERLAY SYSTEM Q25 Q25/140 NATURAL STONE SETT PAVING SYSTEM Q25 Q25/145 NATURAL STONE SETT OVERLAY PAVING SYSTEM Q25 Q25/150 CONCRETE SETT PAVING SYSTEM Q25 Q25/155 CONCRETE SETT PAVING OVERLAY SYSTEM Q25 Q25/160 NATURAL STONE COBBLE PAVING SYSTEM Q25 Q25/165 NATURAL STONE COBBLE OVERLAY PAVING SYSTEM Q25 Q25/170 PRECAST CONCRETE AND GRASS PAVING SYSTEM Q25 Q25/175 PRECAST CONCRETE AND GRAVEL PAVING SYSTEM Q25 Q25/180 PLASTICS GRASS REINFORCING PAVING SYSTEM Q25 Q25/185 GRAVEL FILLED PLASTICS PAVING SYSTEM Q25 Q25/190 HARD LANDSCAPING MATERIALS SPECIFICATION Q25 Q25/210 DESIGN - NATURAL STONE SLAB PAVING SYSTEM Q25 Q25/220 DESIGN - CONCRETE FLAG PAVING SYSTEM Q25 Q25/230 DESIGN - RIGID BRICK PAVING SYSTEM Q25 Q25/240 DESIGN - NATURAL STONE SETT PAVING SYSTEM Q25 Q25/250 DESIGN - CONCRETE SETT PAVING SYSTEM Q25 Q25/260 DESIGN - NATURAL STONE COBBLE PAVING SYSTEM Q25 Q25/270 DESIGN - PRECAST CONCRETE AND GRASS PAVING SYSTEM Q25 Q25/275 DESIGN - PRECAST CONCRETE AND GRAVEL PAVING SYSTEM Q25 Q25/280 DESIGN - PLASTICS GRASS REINFORCING PAVING SYSTEM Q25 Q25/285 DESIGN - GRAVEL FILLED PLASTICS PAVING SYSTEM Q25 Q25/305 GRANULAR MATERIAL FOR LAYER OVER EXISTING BASES Q25 Q25/310 NATURAL STONE SLABS Q25 Q25/315 CONCRETE FLAGS Q25 Q25/320 TACTILE FLAGS AND SLABS Q25 Q25/325 BRICKS Q25 Q25/330 NATURAL STONE SETTS Q25 Q25/335 CONCRETE SETTS Q25 Q25/340 NATURAL STONE COBBLES Q25 Q25/345 PRECAST UNITS FOR CONCRETE AND GRASS PAVING Q25 Q25/350 PLASTICS PAVERS Q25 Q25/365 GEOTEXTILE SHEET Q25 Q25/370 CEMENT FOR SITE MIXED MORTAR Q25 Q25/375 SAND/ FINE AGGREGATE FOR SITE MIXED MORTAR Q25 Q25/380 LIME FOR SITE MIXED MORTAR Q25 Q25/390 SAND FOR FLEXIBLE LAYING COURSE AND JOINTING OF CONCRETE FLAG PAVING Q25 Q25/400 SAND FOR LAYING COURSE OF GRASSED OR GRAVEL FILLED PAVING Q25 Q25/420 FINE AGGREGATE FOR LAYING COURSE OF CONCRETE SETT PAVING Q25 Q25/425 FINE AGGREGATE FOR JOINTING CONCRETE SETT PAVING Q25 Q25/435 PRIMER FOR UNDERSIDE OF FLAGS AND SLABS Q25 Q25/440 READY MIXED MORTAR Q25 Q25/445 READY MIXED FINE CONCRETE Q25 Q25/450 GRAVEL FILLING Q25 Q25/455 JOINT FILLER FOR MOVEMENT JOINTS Q25 Q25/460 JOINT BREAKER BARRIERS FOR MOVEMENT JOINTS Q25 Q25/465 SEALANT FOR MOVEMENT JOINTS Q25 Q25/470 SEALER/ STABILIZER SOLUTION FOR BLOCKS AND SETTS Q25 Q25/475 CLEANING SOLUTION FOR EXISTING BLOCKS AND SETTS Q25 Q25/480 SUPPORT PEDESTALS Q25 Q25/490 APPLIED SLIP RESISTANT Q25 Q25/610 MATERIAL SAMPLES Q25 Q25/615 CONTROL SAMPLES Q25 Q25/620 ADVERSE WEATHER Q25 Q25/625 LAYING PAVINGS - GENERAL Q25 Q25/630 LEVELS OF PAVING Q25 Q25/635 REGULARITY OF PAVED SURFACES Q25 Q25/637 REGULARITY OF PAVED SURFACES Q25 Q25/640 COLOUR BANDING Q25 Q25/645 PROTECTION Q25 Q25/650 CEMENTITIOUS BASES AND SUB-BASES Q25 Q25/655 CONDITION OF SUB-BASES/ BASES BEFORE SPREADING LAYING COURSE Q25 Q25/660 DRAINAGE HOLES IN EXISTING BASES Q25 Q25/665 PLANING AND REPAIRS TO EXISTING BASES Q25 Q25/670 LAYING GRANULAR LAYER OVER EXISTING BASES Q25 Q25/675 LAYING GEOTEXTILE SHEET EDGING STRIPS Q25 Q25/680 LAYING GEOTEXTILE SHEET PATCHES OVER DRAINAGE HOLES Q25 Q25/685 LAYING GEOTEXTILE SHEET OVERLAYS Q25 Q25/690 RECLAIMED NATURAL STONE Q25 Q25/695 SITE MIXED MORTAR Q25 Q25/700 SITE MIXED FINE CONCRETE Q25 Q25/705 SITE MIXED SAND AND SOIL FOR GRASS REINFORCING PLASTICS PAVERS Q25 Q25/710 LAYING FLAG AND SLAB PAVING - SAND LAYING COURSE AND JOINTING Q25 Q25/715 LAYING FLAG AND SLAB PAVING - MORTAR LAYING COURSE AND JOINTING Q25 Q25/725 LAYING RIGID BRICK PAVING Q25 Q25/730 LAYING NATURAL STONE SETT PAVING Q25 Q25/735 LAYING CONCRETE SETT PAVING - MORTAR BEDDED Q25 Q25/740 LAYING CONCRETE SETT PAVING - FINE AGGREGATE BEDDING AND JOINTING Q25 Q25/750 LAYING NATURAL STONE COBBLE PAVING Q25 Q25/755 LAYING PRECAST CONCRETE AND GRASS PAVING Q25 Q25/760 LAYING PRECAST CONCRETE AND GRAVEL PAVING Q25 Q25/765 LAYING PLASTICS GRASS REINFORCING PAVERS Q25 Q25/770 LAYING GRAVEL FILLED PLASTICS PAVERS Q25 Q25/780 LAYING MORTAR BEDDED ACCESSORIES Q25 Q25/785 TOOLED JOINTS IN MORTAR BEDDED UNITS Q25 Q25/790 TOOLED COLOURED JOINTS IN MORTAR BEDDED UNITS Q25 Q25/795 SEALANT MOVEMENT JOINTS IN MORTAR BEDDED UNITS Q25 Q25/800 APPLYING SEALER/ STABILIZER TO BLOCKS AND SETTS Q25 Q25/805 CLEANING EXISTING BLOCKS AND SETTS Q25 Q25/810 PEDESTAL INSTALLATION Q25 Q25/915 COMPLETION OF PAVING WITH DRY SAND OR FINE AGGREGATE FILLED JOINTS Q25 Q25/920 COMPLETION OF GRASSED PAVINGS Q25 Q26 SPECIAL SURFACINGS/ PAVINGS FOR SPORT/ GENERAL AMENITY Q Q26/110 INFORMATION TO BE PROVIDED BY THE CONTRACTOR Q26 Q26/120 SURFACING FOR Q26 Q26/130 SURFACING FOR Q26 Q26/140 SURFACE GRADIENTS, EVENNESS AND FLATNESS Q26 Q26/150 SUITABILITY OF BASE/ SUB-BASE Q26 Q26/210 FILLED SYNTHETIC SPORTS TURF SURFACING Q26 Q26/220 UNFILLED SYNTHETIC SPORTS TURF SURFACING Q26 Q26/230 IN SITU POLYMERIC SURFACING Q26 Q26/240 SHEET FORM GRANULAR RUBBER SURFACING Q26 Q26/250 ACRYLIC COATED SURFACING Q26 Q26/260 RESIN BOUND STONE AGGREGATE SURFACING Q26 Q26/270 FAST-DRY CLAY SURFACING Q26 Q26/280 SYNTHETIC MATTING FOR DRY SKI SLOPES Q26 Q26/300 EXTENT OF IMPACT ABSORBING SURFACING Q26 Q26/301 EXTENT OF IMPACT ABSORBING SURFACING Q26 Q26/310 BARK SURFACING Q26 Q26/320 WOODCHIP SURFACING Q26 Q26/330 SAND SURFACING Q26 Q26/340 RUBBER MAT AND TILE SURFACING Q26 Q26/350 SYNTHETIC GRASS SURFACING Q26 Q26/360 IN SITU SYNTHETIC SURFACING Q26 Q26/410 FLUSH EDGING TO SURFACING TYPE Q26/ Q26 Q26/415 RAISED EDGING TO SURFACING TYPE Q26/ Q26 Q26/420 LINE MARKINGS TO SURFACING TYPE Q26/ Q26 Q26/430 EDGES Q26 Q26/440 STUMP BOXES TO CRICKET WICKETS Q26 Q26/710 SYNTHETIC SPORTS TURF INSTALLATION Q26 Q26/720 FAST-DRY CLAY TENNIS COURT INSTALLATION Q26 Q26/910 SPORTS SURFACE TESTING Q26 Q26/920 PLAY SURFACE TESTING Q26 Q26/930 DOCUMENTATION Q26 Q26/940 LABELLING Q26 Q28 TOPSOIL AND SOIL AMELIORANTS Q Q28/110 NATURALLY OCCURRING TOPSOIL SYSTEM Q28 Q28/120 MANUFACTURED TOPSOIL/ GROWING MEDIA SYSTEM Q28 Q28/300 PREPARATION MATERIALS GENERALLY Q28 Q28/305 PERMITTED MATERIALS Q28 Q28/310 MATERIALS NOT PERMITTED Q28 Q28/315 IMPORTED TOPSOIL TO BS 3882 Q28 Q28/320 IMPORTED TOPSOIL FROM A SPECIFIED SOURCE Q28 Q28/325 IMPORTED TOPSOIL, CUSTOM MIX Q28 Q28/330 IMPORTED MANUFACTURED TOPSOIL/ GROWING MEDIUM Q28 Q28/335 IMPORTED MANUFACTURED TOPSOIL, CUSTOM MIX Q28 Q28/340 SPECIAL IMPORTED TOPSOIL AND/ OR GROWING MEDIA Q28 Q28/345 AGGREGATES Q28 Q28/350 MINERALS Q28 Q28/355 ORGANIC MATERIALS Q28 Q28/360 SANITIZED AND STABILIZED COMPOSTED MATERIALS CERTIFIED TO PAS 100 Q28 Q28/370 TEMPORARY CROPS GROWN ON SITE Q28 Q28/375 INDUSTRIAL BY-PRODUCTS Q28 Q28/380 MYCORRHIZAL INOCULANT Q28 Q28/385 GEL WATER RETENTION SYSTEMS Q28 Q28/390 FERTILIZERS TO BE INCORPORATED INTO TOPSOIL AND MANUFACTURED TOPSOIL Q28 Q28/395 FERTILIZERS FOR CONTAINER PLANTING Q28 Q28/400 MAINTENANCE FERTILIZERS Q28 Q28/605 SITE INVESTIGATION Q28 Q28/610 TOPSOIL ANALYSIS Q28 Q28/615 TESTING OF MATERIALS Q28 Q28/620 IMPORTING TOPSOIL Q28 Q28/625 SAMPLE LOADS Q28 Q28/630 DOCUMENTATION FOR IMPORTED TOPSOIL Q28 Q28/635 DOCUMENTATION FOR COMPOST AND COMPOSTED MATERIALS Q28 Q28/640 DOCUMENTATION FOR PREPARATION MATERIALS Q28 Q28/650 NOTICE Q28 Q28/655 MECHANICAL TOOLS Q28 Q28/660 GRADING SUBSOIL Q28 Q28/665 SUBSOIL SURFACE PREPARATION Q28 Q28/670 INSPECTING FORMATIONS Q28 Q28/675 PREPARATION OF UNDISTURBED TOPSOIL Q28 Q28/680 SURPLUS TOPSOIL TO BE RETAINED Q28 Q28/685 SURPLUS MATERIALS TO BE REMOVED Q28 Q28/690 TOPSOIL STORAGE HEAPS Q28 Q28/695 CULTIVATION Q28 Q28/700 GRADING OF TOPSOIL Q28 Q28/705 HANDLING TOPSOIL Q28 Q28/710 SPREADING TOPSOIL Q28 Q28/715 LOOSE TIPPING OF TOPSOIL Q28 Q28/720 FINISHED LEVELS OF TOPSOIL AFTER SETTLEMENT Q28 Q28/725 SPORTSFIELDS Q28 Q28/750 SITE-MADE TOPSOIL Q28 Q28/755 SITE-MADE GROWING MEDIA Q28 Q28/770 SITE-MADE COMPOSTING FACILITIES Q28 Q28/800 SOWING TEMPORARY CROPS Q28 Q28/805 APPLYING SOIL AMELIORANT Q28 Q28/810 APPLYING COMPOST Q28 Q28/815 APPLYING LIME Q28 Q28/820 APPLYING GENERAL FERTILIZER Q28 Q28/825 APPLYING FERTILIZER TO PROPOSED GRASS AREAS Q28 Q28/835 APPLYING BURIED GEL IRRIGATION SYSTEM Q28 Q28/840 APPLYING MYCORRHIZAL INOCULANT Q28 Q28/905 APPLYING MAINTENANCE FERTILIZER Q28 Q28/915 FEEDING AND FERTILIZING CONTAINER PLANTING Q28 Q30 SEEDING/ TURFING Q Q30/115 SEEDED AND TURFED AREAS Q30 Q30/120 CLIMATIC CONDITIONS Q30 Q30/145 WATERING Q30 Q30/146 WATERING Q30 Q30/150 WATER RESTRICTIONS Q30 Q30/160 NOTICE Q30 Q30/170 SETTING OUT Q30 Q30/210 HERBICIDE Q30 Q30/212 SEED BED CLEANING BEFORE SOWING Q30 Q30/280 FINAL CULTIVATION Q30 Q30/290 PREPARATION FOR HYDRAULIC SEEDING Q30 Q30/310 GRASS SEED Q30 Q30/311 GRASS SEED Q30 Q30/312 SEED MIXTURE Q30 Q30/319 QUALITY OF SEED Q30 Q30/320 QUALITY OF SEED Q30 Q30/330 SOWING Q30 Q30/335 GRASS SOWING SEASON Q30 Q30/336 WILDFLOWER SOWING SEASON Q30 Q30/340 PRE-EMERGENT HERBICIDE Q30 Q30/350 TURF EDGING TO SEEDED AREAS Q30 Q30/352 EDGES TO SEEDED AREAS Q30 Q30/355 SURFACE REINFORCEMENT MAT/ MESH Q30 Q30/361 REINFORCED GRASS SYSTEM Q30 Q30/365 PRESEEDED MATTING Q30 Q30/370 HYDRAULIC SEEDING Q30 Q30/380 HYDRAULIC SEEDING Q30 Q30/400 CULTIVATED TURF Q30 Q30/405 CULTIVATED TURF Q30 Q30/410 TURF TO BS 3969 Q30 Q30/420 DELIVERY AND STORAGE Q30 Q30/423 INSPECTION OF TURF Q30 Q30/427 WEED SUPPRESSION MEMBRANE Q30 Q30/428 COMPOST DRESSING FOR TURF Q30 Q30/429 DRESSING FOR TURF Q30 Q30/430 TURFING GENERALLY Q30 Q30/440 TURFING ON BANKS EXCEEDING 30° SLOPE Q30 Q30/445 TURF NETTING Q30 Q30/450 TRIMMING TURF Q30 Q30/510 PROTECTIVE FENCING Q30 Q30/530 FIRST CUT OF GRASSED AREAS Q30 Q30/540 FIRST CUT OF Q30 Q30/550 AREAS NOT TO BE CUT Q30 Q30/560 GRASS EDGING STRIPS Q30 Q30/565 TIMBER/ PLASTICS EDGINGS Q30 Q30/567 GALVANIZED STEEL EDGINGS Q30 Q30/570 PLASTICS MESH REINFORCEMENT Q30 Q30/580 PLASTICS PAVING SYSTEMS Q30 Q30/590 CLEANLINESS Q30 Q30/610 FAILURES OF SEEDING/TURFING Q30 Q30/620 MAINTAINING Q30 Q30/650 MAINTAINING GRASSED AREAS WITH PERENNIAL WILD FLOWERS Q30 Q30/660 MAINTAINING GRASSED AREAS WITH ANNUAL WILD FLOWERS Q30 Q30/680 MAINTENANCE FERTILIZER Q30 Q30/685 MAINTENANCE FERTILIZER Q30 Q31 EXTERNAL PLANTING Q Q31/112 SITE CLEARANCE GENERALLY Q31 Q31/115 SITE CLEARANCE FOR AQUATIC/ MARGINAL PLANTING Q31 Q31/118 SOIL CONDITIONS Q31 Q31/120 CLIMATIC CONDITIONS Q31 Q31/125 TIMES OF YEAR FOR PLANTING Q31 Q31/130 MECHANICAL TOOLS Q31 Q31/145 WATERING Q31 Q31/146 WATERING Q31 Q31/150 WATER RESTRICTIONS Q31 Q31/160 NOTICE Q31 Q31/165 PREPARATION, PLANTING AND MULCHING MATERIALS Q31 Q31/200 PLANTS/ TREES - GENERAL Q31 Q31/215 PLANTS/ TREES - SPECIFICATION CRITERIA Q31 Q31/216 PLANTS/ TREES - SPECIFICATION CRITERIA Q31 Q31/225 BULBS/ CORMS/ TUBERS Q31 Q31/235 CONTAINER GROWN PLANTS/ TREES Q31 Q31/245 LABELLING AND INFORMATION Q31 Q31/246 LABELLING AND INFORMATION Q31 Q31/255 PLANTS/ TREES RESERVED AT SUPPLIER'S PREMISES Q31 Q31/260 PLANT/ TREE SUBSTITUTION Q31 Q31/265 PLANT HANDLING, STORAGE TRANSPORT AND PLANTING Q31 Q31/275 PERMANENT IDENTIFICATION OF PLANTS Q31 Q31/280 TREATMENT OF TREE WOUNDS Q31 Q31/285 PROTECTION OF EXISTING GRASS Q31 Q31/290 SURPLUS MATERIAL Q31 Q31/292 PREFABRICATED PLANT CONTAINERS Q31 Q31/294 HANGING PLANT CONTAINERS Q31 Q31/296 TIMBER PLANT CONTAINERS Q31 Q31/297 TIMBER PLANT CONTAINERS Q31 Q31/298 WATERPROOFING LINING Q31 Q31/300 HERBICIDE Q31 Q31/305 WEED CONTROL Q31 Q31/375 CULTIVATION Q31 Q31/385 MULCH MATTING/ GEOTEXTILE FABRIC Q31 Q31/390 GEOTEXTILE FABRIC LINING FOR AQUATIC/ MARGINAL PLANTING Q31 Q31/400 RANDOM PLANT LAYOUT Q31 Q31/401 REGULAR PLANT LAYOUT Q31 Q31/405 SHRUB PLANTING PITS Q31 Q31/410 BURIED GEL IRRIGATION SYSTEM Q31 Q31/415 ANTIDESICCANT FOR CONIFERS/ EVERGREENS Q31 Q31/417 MYCORRHIZAL INOCULANT Q31 Q31/420 CLIMBING PLANTS Q31 Q31/435 CLIMBING PLANTS USED AS GROUND COVER Q31 Q31/445 PLANTING BULBS/ CORMS/ TUBERS Q31 Q31/455 PLANTING WILD FLOWER PLUGS Q31 Q31/457 PLANTING AQUATIC/ MARGINAL PLANT PLUGS Q31 Q31/459 NOTCH PLANTING BARE ROOT AQUATIC PLANTS Q31 Q31/461 PLANTING CONTAINERIZED, BAGGED AND WEIGHTED BUNCH AQUATIC PLANTS Q31 Q31/462 BALLASTING AQUATIC AND MARGINAL PLANTING Q31 Q31/463 PREPLANTED MATS Q31 Q31/470 FORMAL HEDGES Q31 Q31/471 NATURALIZED HEDGES Q31 Q31/472 FENCING SUPPORT FOR NEW HEDGES Q31 Q31/476 SHRUB, HERBACEOUS AND BULB BACKFILLING MATERIAL Q31 Q31/480 AFTER PLANTING Q31 Q31/485 MULCHING PLANTING BEDS Q31 Q31/486 SHRUB PROTECTION Q31 Q31/490 INDIVIDUAL MULCH MATS Q31 Q31/500 ANTIDESICCANT FOR CONIFERS/ EVERGREENS Q31 Q31/505 TREE PITS Q31 Q31/510 TREE PIT ROOT BARRIERS Q31 Q31/512 TREE PIT ACCESSORIES Q31 Q31/515 TREE PIT DRAINAGE Q31 Q31/525 SEMIMATURE TREES Q31 Q31/535 STAKING GENERALLY Q31 Q31/545 LONG SINGLE STAKING FOR Q31 Q31/555 SHORT SINGLE STAKING FOR Q31 Q31/565 LONG DOUBLE STAKING FOR Q31 Q31/575 SHORT DOUBLE STAKING FOR Q31 Q31/586 TREE BACKFILLING MATERIAL Q31 Q31/590 MULCHING TREES Q31 Q31/595 TREE PROTECTION Q31 Q31/597 TREE SPATS/ MULCH MATS Q31 Q31/600 WOODLAND WORK GENERALLY Q31 Q31/605 EXISTING VEGETATION/ WEED CLEARANCE Q31 Q31/615 EXISTING TREES/ SEEDLINGS/ COPPICE SHOOTS Q31 Q31/617 REMOVING TREES AND HEDGES Q31 Q31/625 CULTIVATION Q31 Q31/635 NOTCH PLANTING IN UNCULTIVATED GROUND Q31 Q31/645 PLANTING IN TURF Q31 Q31/655 FURROW PLANTING Q31 Q31/665 SETTING OUT Q31 Q31/680 SETTING OUT Q31 Q31/710 MAINTENANCE Q31 Q31/720 FAILURES OF PLANTING Q31 Q31/730 PROTECTIVE FENCING Q31 Q31/740 CLEANLINESS Q31 Q31/750 PLANTING MAINTENANCE GENERALLY Q31 Q31/755 PLANTING MAINTENANCE - FERTILIZER Q31 Q31/760 PLANTING MAINTENANCE - PRUNING Q31 Q31/770 WOODLAND PLANTING MAINTENANCE Q31 Q31/780 MAINTENANCE INSTRUCTIONS Q31 Q31/790 FINAL MULCHING Q31 Q32 INTERNAL AND ARTIFICIAL PLANTING Q Q32/110 INTERNAL ENVIRONMENT Q32 Q32/120 SUITABILITY OF INTERNAL ENVIRONMENT Q32 Q32/130 PLANT SUBSTITUTION Q32 Q32/140 PREPARATION, PLANTING AND MULCHING MATERIALS Q32 Q32/150 DRAINAGE LAYER Q32 Q32/160 SOIL SEPARATORS Q32 Q32/170 PEAT Q32 Q32/190 COMPOST Q32 Q32/200 PROPRIETARY PREMIXED COMPOST Q32 Q32/210 HYDROCULTURE Q32 Q32/233 WATERING Q32 Q32/240 WATER RESTRICTIONS Q32 Q32/260 NOTICE Q32 Q32/270 IN SITU PLANT CONTAINERS Q32 Q32/275 PREFABRICATED PLANT CONTAINERS Q32 Q32/280 TIMBER PLANT CONTAINERS - PRESERVATIVE TREATED Q32 Q32/281 TIMBER PLANT CONTAINERS Q32 Q32/290 PREFORMED WATERPROOF LININGS Q32 Q32/310 PLANTS - GENERAL Q32 Q32/320 CONTAINER GROWN PLANTS Q32 Q32/330 SPECIFICATION CRITERIA TO BS 3936 Q32 Q32/331 SPECIFICATION CRITERIA TO THE NATIONAL PLANT SPECIFICATION Q32 Q32/332 SPECIFICATION CRITERIA TO ANSI Z60.1 Q32 Q32/345 PLANTS RESERVED AT SUPPLIER'S PREMISES Q32 Q32/371 LABELLING AND INFORMATION Q32 Q32/372 LABELLING AND INFORMATION Q32 Q32/410 PLANT HANDLING, STORAGE AND TRANSPORT Q32 Q32/420 PLANTING Q32 Q32/430 PLANTING CLIMBING PLANTS Q32 Q32/435 CLIMBING PLANTS USED AS GROUND COVER Q32 Q32/440 PLANTING SHRUBS Q32 Q32/450 PLANTING TREES Q32 Q32/460 ANTIDESICCANT FOR CONIFERS/ EVERGREENS Q32 Q32/470 TREE WORK GENERALLY Q32 Q32/490 PERMANENT IDENTIFICATION OF PLANTS Q32 Q32/510 POLYESTER SILK PLANTS Q32 Q32/520 PRESERVED PLANTS Q32 Q32/530 LIGHTWEIGHT FIXING MEDIUM Q32 Q32/540 IN SITU CONCRETE FIXING MEDIUM Q32 Q32/550 INSTALLATION OF ARTIFICIAL PLANTS Q32 Q32/600 AFTERCARE UP TO COMPLETION Q32 Q32/610 MAINTENANCE Q32 Q32/620 FAILURES OF PLANTING Q32 Q32/630 PLANTING MAINTENANCE Q32 Q32/635 ARTIFICIAL PLANTING MAINTENANCE Q32 Q32/640 FEEDING AND FERTILIZING Q32 Q32/650 MAINTENANCE INSTRUCTIONS Q32 Q32/660 FINAL MULCHING Q32 Q35 LANDSCAPE MAINTENANCE Q Q35/105 MAINTENANCE OBJECTIVES Q35 Q35/110 NOTICE Q35 Q35/130 REINSTATEMENT Q35 Q35/140 CONTROL OF MAMMALIAN PESTS Q35 Q35/145 CONTROL OF INVASIVE ANIMAL SPECIES Q35 Q35/150 PERFORMANCE CRITERIA FOR CONTROL OF INVASIVE ANIMAL SPECIES Q35 Q35/152 PERFORMANCE CRITERIA FOR CONTROL OF INVASIVE PLANT SPECIES Q35 Q35/155 WATERING Q35 Q35/156 WATERING Q35 Q35/160 WATER RESTRICTIONS Q35 Q35/170 DISPOSAL OF ARISINGS Q35 Q35/175 DISPOSAL OF ARISINGS Q35 Q35/180 CHIPPING OR SHREDDING Q35 Q35/181 MECHANICAL EQUIPMENT Q35 Q35/190 LITTER Q35 Q35/195 PROTECTION OF EXISTING GRASS Q35 Q35/197 CLEANLINESS Q35 Q35/210 MAINTENANCE OF GRASSED AREAS Q35 Q35/211 MAINTENANCE OF GRASSED AREAS Q35 Q35/220 GRASS CUTTING GENERALLY Q35 Q35/225 TREE STEMS Q35 Q35/226 TREE STEMS Q35 Q35/235 BULBS AND CORMS IN GRASSED AREAS Q35 Q35/240 MOWING STRIPS Q35 Q35/250 LEAF REMOVAL Q35 Q35/255 FIRST CUT OF Q35 Q35/260 MOWING LAWNS Q35 Q35/262 MOWING SPORTS FIELDS Q35 Q35/265 MOWING GENERAL AREAS Q35 Q35/270 MOWING ROUGH GRASSED AREAS Q35 Q35/272 MAINTAINING GRASSED AREAS WITH PERENNIAL WILD FLOWERS Q35 Q35/273 MAINTAINING GRASSED AREAS WITH ANNUAL WILD FLOWERS Q35 Q35/275 CUTTING SUMMER FLOWERING WILD FLOWER MEADOWS Q35 Q35/280 CUTTING SPRING FLOWERING WILD FLOWER MEADOWS Q35 Q35/285 TOP DRESSING Q35 Q35/290 ROLLING Q35 Q35/295 SPIKING Q35 Q35/300 SCARIFYING Q35 Q35/305 HARROWING Q35 Q35/307 HOLLOW TINING Q35 Q35/309 EDGES TO SEEDED AREAS Q35 Q35/310 RE-FORMING GRASS EDGES Q35 Q35/311 RE-FORMING GRASS EDGES Q35 Q35/320 LEVELLING HOLLOWS AND BUMPS IN TURF Q35 Q35/325 RELIEVING SURFACE COMPACTION IN TURF Q35 Q35/330 SELECTIVE HERBICIDE Q35 Q35/340 SPOT WEEDKILLING IN ROUGH GRASS AREAS Q35 Q35/345 CONTROL OF JAPANESE KNOTWEED Q35 Q35/350 FERTILIZER - SPRING APPLICATION Q35 Q35/360 FERTILIZER - AUTUMN APPLICATION Q35 Q35/370 WORM CONTROL Q35 Q35/375 PEST CONTROL Q35 Q35/380 REINSTATEMENT OF DAMAGED LAWNS Q35 Q35/381 REINSTATEMENT OF WORN OR DAMAGED LAWNS Q35 Q35/450 PLANTING BEDS OF ANNUALS Q35 Q35/460 BEDS OF PERENNIALS OR PERENNIALS AND ANNUALS Q35 Q35/470 FLOWER BEDS GENERALLY Q35 Q35/480 CONSERVATION OF TENDER PERENNIALS Q35 Q35/490 THINNING BY REMOVAL OF SURPLUS PLANTS Q35 Q35/500 ESTABLISHMENT OF NEW PLANTING Q35 Q35/502 ESTABLISHMENT OF NEW PLANTING - FERTILIZER Q35 Q35/510 TREE STAKES AND TIES Q35 Q35/515 TREE GUY WIRES Q35 Q35/520 REFIRMING OF TREES AND SHRUBS Q35 Q35/525 TREE GUARDS Q35 Q35/530 TREE SHELTERS Q35 Q35/535 TREE GRILLES Q35 Q35/540 PRUNING GENERALLY Q35 Q35/545 PRUNING OF EXCESSIVE OVERHANG Q35 Q35/550 PRUNING OF EXCESSIVE HEIGHT Q35 Q35/555 PRUNING TREES AND SHRUBS Q35 Q35/570 FORMATIVE PRUNING OF YOUNG TREES Q35 Q35/575 PRUNING ORNAMENTAL SHRUBS Q35 Q35/580 PRUNING FLOWERING SPECIES OF SHRUBS AND ROSES Q35 Q35/590 PRUNING PARTICULAR SPECIES Q35 Q35/600 TRIMMING RAPIDLY ESTABLISHING HEDGES Q35 Q35/605 TRIMMING SLOWLY ESTABLISHING HEDGES Q35 Q35/610 TRIMMING TAPERING ESTABLISHED HEDGES Q35 Q35/611 TRIMMING NONTAPERING ESTABLISHED HEDGES Q35 Q35/615 TRIMMING FIELD HEDGES Q35 Q35/620 REMOVAL OF DEAD PLANT MATERIAL Q35 Q35/625 CLIMBING PLANTS Q35 Q35/630 DEAD AND DISEASED PLANTS Q35 Q35/635 REINSTATEMENT OF SHRUB/ HERBACEOUS AREAS Q35 Q35/640 THINNING BY REMOVAL OF SURPLUS PLANTS Q35 Q35/642 THINNING BY TRANSPLANTING SURPLUS PLANTS Q35 Q35/645 WEED CONTROL GENERALLY Q35 Q35/650 HAND WEEDING Q35 Q35/655 WEED CUTTING BY HAND OR MACHINE Q35 Q35/657 HERBICIDE TO KILL REGROWTH Q35 Q35/665 WEED CONTROL WITH WINTER HERBICIDE Q35 Q35/670 WEED CONTROL WITH SUMMER HERBICIDE Q35 Q35/675 DIGGING OVER Q35 Q35/680 SOIL AERATION Q35 Q35/685 SOIL LEVEL ADJUSTMENT Q35 Q35/690 MAINTENANCE OF LOOSE MULCH Q35 Q35/693 MAINTENANCE OF MULCH MATTING/ SHEET MULCHES Q35 Q35/695 FERTILIZING ESTABLISHED TREES AND SHRUBS Q35 Q35/700 SNOW REMOVAL FROM SHRUBS/ TREES Q35 Q35/705 WINTER LEAF REMOVAL Q35 Q35/710 WOODLAND PLANTING MAINTENANCE Q35 Q35/715 WOODLAND THINNING Q35 Q35/720 COPPICING Q35 Q35/810 TREE WORK GENERALLY Q35 Q35/815 ADDITIONAL WORK Q35 Q35/820 PREVENTION OF WOUND BLEEDING Q35 Q35/825 PREVENTION OF DISEASE TRANSMISSION Q35 Q35/830 CLEANING OUT AND DEADWOODING Q35 Q35/835 CUTTING AND PRUNING GENERALLY Q35 Q35/840 CROWN REDUCTION/ SHAPING Q35 Q35/845 CROWN LIFTING Q35 Q35/850 CROWN THINNING Q35 Q35/855 CUTTING TREE ROOTS Q35 Q35/860 REMOVING TREES, SHRUBS AND HEDGES Q35 Q35/865 BARK DAMAGE Q35 Q35/870 CAVITIES IN TREES Q35 Q35/890 DREDGING TO Q35 Q35/895 CLEARANCE OF WATERCOURSES Q35 Q35/900 SNOW CLEARANCE Q35 Q35/910 HARD SURFACES AND GRAVEL AREAS Q35 Q35/915 PAVING SEALANT Q35 Q35/920 FENCING Q35 Q35/930 GRAFFITI REMOVAL Q35 Q37 GREEN ROOFS Q Q37/110 INTENSIVE GREEN ROOF Q37 Q37/120 SIMPLE INTENSIVE GREEN ROOF Q37 Q37/130 EXTENSIVE GREEN ROOF Q37 Q37/140 PAVING AND DECKING SYSTEMS Q37 Q37/210 GENERAL DESIGN Q37 Q37/255 MAXIMUM PERMITTED GREEN ROOF LOADS Q37 Q37/310 INVERTED ROOF INSULATION Q37 Q37/320 ROOT BARRIER Q37 Q37/325 SLIP LAYER Q37 Q37/330 PROTECTION LAYER Q37 Q37/335 SEPARATION LAYER Q37 Q37/340 MOISTURE RETENTION MAT Q37 Q37/350 DRAINAGE LAYER Q37 Q37/355 COMBINED LAYERS Q37 Q37/360 FILTER MEMBRANE Q37 Q37/370 INTENSIVE GROWING MEDIUM Q37 Q37/380 SIMPLE INTENSIVE GROWING MEDIUM Q37 Q37/390 EXTENSIVE GROWING MEDIUM Q37 Q37/400 VEGETATION BLANKET Q37 Q37/410 ANTI-EROSION MAT Q37 Q37/420 EDGE RETAINING PROFILE Q37 Q37/430 INSPECTION CHAMBERS Q37 Q37/440 VEGETATION BARRIER Q37 Q37/450 ROOF DRAINAGE OUTLETS Q37 Q37/460 SUPPORT PEDESTALS Q37 Q37/710 INSTALLATION GENERALLY Q37 Q37/720 ADVERSE WEATHER Q37 Q37/730 INSTALLATION OF INVERTED ROOF INSULATION Q37 Q37/740 ROOT BARRIER INSTALLATION Q37 Q37/750 PROTECTION LAYER INSTALLATION Q37 Q37/755 SEPARATION LAYER INSTALLATION Q37 Q37/760 MOISTURE RETENTION MAT INSTALLATION Q37 Q37/770 DRAINAGE LAYER INSTALLATION Q37 Q37/780 FILTER MEMBRANE INSTALLATION Q37 Q37/790 GROWING MEDIUM INSTALLATION Q37 Q37/800 VEGETATION BLANKET INSTALLATION Q37 Q37/810 ANTI-EROSION MAT INSTALLATION Q37 Q37/820 EDGE RETAINING PROFILE INSTALLATION Q37 Q37/830 INSPECTION CHAMBER INSTALLATION Q37 Q37/840 PEDESTAL INSTALLATION Q37 Q37/910 INSPECTION Q37 Q37/920 COMPLETION Q37 Q37/930 DOCUMENTATION Q37 Q40 FENCING Q Q40/110 CHAIN LINK FENCING Q40 Q40/120 ANTI-INTRUDER FENCING Q40 Q40/125 OPEN MESH STEEL PANEL GENERAL PURPOSE FENCING Q40 Q40/126 OPEN MESH STEEL PANEL SECURITY FENCING Q40 Q40/130 TENNIS COURT CHAIN LINK FENCING AND GATES Q40 Q40/140 GENERAL PATTERN WIRE MESH FENCING Q40 Q40/141 SPRING STEEL AND HIGH TENSILE WIRE MESH FENCING Q40 Q40/150 GENERAL PATTERN STRAINED WIRE FENCING Q40 Q40/151 DROPPER PATTERN STRAINED WIRE FENCING Q40 Q40/160 ELECTRIC SECURITY FENCING Q40 Q40/165 ELECTRIC FENCING Q40 Q40/170 ACOUSTIC FENCING Q40 Q40/210 WOODEN POST AND RAIL FENCING Q40 Q40/220 STEEL FENCING Q40 Q40/230 CONCRETE POST AND RAIL FENCING Q40 Q40/250 PREFABRICATED WOOD PANEL FENCING Q40 Q40/260 CONCRETE POST AND PANEL FENCING Q40 Q40/310 CLOSE BOARDED FENCING Q40 Q40/320 CLEFT CHESTNUT PALE FENCING Q40 Q40/325 WATTLE HURDLE FENCING Q40 Q40/330 WOODEN PALISADE FENCING Q40 Q40/340 STEEL VERTICAL BAR FENCING Q40 Q40/350 STEEL PALISADE FENCING Q40 Q40/360 CONCRETE PALISADE FENCING Q40 Q40/370 WROUGHT IRON Q40 Q40/380 PLASTICS Q40 Q40/410 PURPOSE MADE FENCING Q40 Q40/430 PROPRIETARY FENCING Q40 Q40/440 BOUNDARY PROTECTION MATERIALS SPECIFICATION Q40 Q40/510 FIELD GATES AND POSTS Q40 Q40/520 BRIDLE GATES AND POSTS Q40 Q40/530 KISSING GATES AND POSTS Q40 Q40/540 STILES Q40 Q40/545 DOG GATES Q40 Q40/550 WOOD Q40 Q40/560 STEEL Q40 Q40/565 PLASTICS Q40 Q40/570 GATES Q40 Q40/580 WROUGHT IRON Q40 Q40/625 ADDITIONAL MESH/ FABRIC Q40 Q40/635 GATE OPENERS Q40 Q40/710 INSTALLATION GENERALLY Q40 Q40/715 COMPETENCE Q40 Q40/720 SETTING POSTS IN CONCRETE Q40 Q40/730 EXPOSED CONCRETE FOUNDATIONS Q40 Q40/740 SETTING POSTS IN EARTH Q40 Q40/750 DRIVEN POSTS Q40 Q40/760 NAILED WOOD RAILS Q40 Q40/765 CLEFT WOOD RAILS Q40 Q40/766 ARRIS RAILS Q40 Q40/770 SITE CUTTING OF WOOD Q40 Q40/780 MAKING GOOD GALVANIZED SURFACES Q40 Q40/790 SITE PAINTING Q40 Q40/910 CLEANING Q40 Q40/920 FIXINGS Q40 Q40/930 GATES Q40 Q41 BARRIERS/ GUARDRAILS Q Q41/110 PEDESTRIAN RESTRAINT SYSTEMS IN METAL Q41 Q41/113 CYCLE BARRIER Q41 Q41/115 MOTORCYCLE BARRIER Q41 Q41/117 EQUESTRIAN ACCESS/ VEHICLE BARRIER Q41 Q41/120 SPORTS GROUND BARRIERS Q41 Q41/125 PROPRIETARY S PORTS GROUND BARRIERS Q41 Q41/130 PROTECTIVE BARRIERS Q41 Q41/135 PROPRIETARY PROTECTIVE BARRIERS Q41 Q41/140 METAL VEHICLE SAFETY PARAPETS Q41 Q41/150 VEHICLE SAFETY PARAPETS - CONCRETE Q41 Q41/160 VEHICLE SAFETY PARAPETS - COMBINED METAL AND CONCRETE Q41 Q41/170 VEHICLE SAFETY FENCES - METAL Q41 Q41/180 VEHICLE SAFETY BARRIERS - CONCRETE Q41 Q41/190 VEHICLE ACCESS POINT BARRIERS Q41 Q41/200 COLLAPSIBLE CAR PARK POSTS Q41 Q41/210 VEHICLE FLOW PLATES Q41 Q41/212 VEHICLE STOPS Q41 Q41/230 HEIGHT RESTRICTORS Q41 Q41/240 HANDRAIL SYSTEMS Q41 Q41/300 CONTRACTOR'S STRUCTURAL DESIGN Q41 Q41/305 PRODUCTION INSPECTION OF POSTS Q41 Q41/310 TESTING SPORTS GROUND BARRIERS Q41 Q41/320 TESTING VEHICLE FENCE POST FOUNDATIONS Q41 Q41/325 TESTING VEHICLE FENCE POST FOUNDATIONS Q41 Q41/330 VERIFICATION OF ANCHORAGES Q41 Q41/340 SITE TESTING ANCHORAGES IN DRILLED HOLES Q41 Q41/405 COMPETENCE Q41 Q41/410 WORK ON OR ADJACENT TO HIGHWAYS Q41 Q41/420 ALIGNMENT Q41 Q41/430 ERECTION GENERALLY Q41 Q41/440 ERECTION OF VEHICLE SAFETY PARAPETS Q41 Q41/450 ERECTION OF VEHICLE SAFETY FENCES Q41 Q41/460 ERECTION OF CONCRETE VEHICLE SAFETY BARRIERS Q41 Q41/470 DRIVING POSTS Q41 Q41/480 CONCRETE FOUNDATIONS FOR POSTS Q41 Q41/490 DAMAGE REPAIR TO GALVANIZED SURFACES Q41 Q41/500 PRESERVATIVE TREATED TIMBER Q41 Q41/510 PREPARATION FOR SITE PAINTING Q41 Q41/900 DOCUMENTATION Q41 Q50 SITE/ STREET FURNITURE/ EQUIPMENT Q Q50/110 WOOD GATE Q50 Q50/120 STEEL GATE Q50 Q50/125 WROUGHT IRON GATE Q50 Q50/130 GATE Q50 Q50/150 PAY AND DISPLAY EQUIPMENT Q50 Q50/155 PARKING METER Q50 Q50/160 TURNSTILE Q50 Q50/190 BOLLARDS Q50 Q50/192 COLLAPSIBLE/ TELESCOPIC BOLLARDS Q50 Q50/194 RETRACTING BOLLARDS Q50 Q50/196 REMOVABLE BOLLARDS Q50 Q50/210 CYCLE STANDS Q50 Q50/212 CYCLE LOCKERS Q50 Q50/214 MOTORCYCLE STANDS Q50 Q50/220 BENCHES Q50 Q50/225 SEATS Q50 Q50/230 TABLES Q50 Q50/240 LITTER BINS Q50 Q50/242 BINS Q50 Q50/244 ASH TRAYS Q50 Q50/252 LEAFLET DISPENSERS Q50 Q50/254 DONATION BOXES Q50 Q50/260 TREE GUARDS Q50 Q50/262 TREE GRILLES Q50 Q50/320 FLAGSTAFF Q50 Q50/330 ROTARY CLOTHES DRIER Q50 Q50/340 BESPOKE SCULPTURE/ LANDSCAPE ART Q50 Q50/345 PROPRIETARY SCULPTURE/ LANDSCAPE ART Q50 Q50/350 NESTING BOXES Q50 Q50/370 COMPOST BINS Q50 Q50/510 CONCRETE FOUNDATIONS GENERALLY Q50 Q50/515 SETTING COMPONENTS IN CONCRETE Q50 Q50/520 SETTING IN EARTH Q50 Q50/530 PRESERVATIVE TREATED TIMBER Q50 Q50/540 BUILDING IN TO MASONRY WALLS Q50 Q50/545 ERECTION OF TIMBER AND PREFABRICATED STRUCTURES Q50 Q50/550 DAMAGE TO GALVANIZED SURFACES Q50 Q50/560 SITE PAINTING Q50 Q52 PLAY AND SPORTS EQUIPMENT Q Q52/115 PLAYGROUND Q52 Q52/125 BASKETBALL COURT Q52 Q52/130 CYCLE COURSE Q52 Q52/133 FOOTBALL PITCH Q52 Q52/137 HOCKEY PITCH Q52 Q52/140 MULTI USE GAMES AREA Q52 Q52/145 NETBALL COURT Q52 Q52/150 RUGBY PITCH Q52 Q52/155 SKATE PARK Q52 Q52/160 TENNIS COURT Q52 Q52/165 TRIM TRAIL Q52 Q52/170 VOLLEYBALL COURT Q52 Q52/175 RIDING ARENA Q52 Q52/210 DESIGN Q52 Q52/215 PLAYGROUND DESIGN Q52 Q52/230 CYCLE COURSE DESIGN Q52 Q52/240 MULTI USE GAMES AREA DESIGN Q52 Q52/255 SKATE PARK DESIGN Q52 Q52/260 COURT DESIGN Q52 Q52/265 TRIM TRAIL DESIGN Q52 Q52/270 PITCH DESIGN Q52 Q52/275 RIDING ARENA DESIGN Q52 Q52/320 BALANCE BEAM Q52 Q52/330 CLIMBING FRAME Q52 Q52/335 CLIMBING WALL Q52 Q52/340 COMBINED PLAY STRUCTURE Q52 Q52/350 SENSORY PLAY STRUCTURE Q52 Q52/355 IMAGINATIVE PLAY STRUCTURE Q52 Q52/360 NON-STANDARD PLAY STRUCTURE Q52 Q52/380 PLAY PANEL Q52 Q52/390 ROCKING EQUIPMENT Q52 Q52/400 RUNWAY Q52 Q52/410 SANDPIT Q52 Q52/420 SLIDE Q52 Q52/430 SPINNING EQUIPMENT Q52 Q52/440 SWINGING EQUIPMENT Q52 Q52/445 SWING SAFETY BARRIER Q52 Q52/450 WATER PLAY EQUIPMENT Q52 Q52/520 BASKETBALL HOOPS Q52 Q52/540 CYCLE RAMP Q52 Q52/560 EXERCISE EQUIPMENT Q52 Q52/580 GOALS Q52 Q52/590 MULTI USE GAMES EQUIPMENT Q52 Q52/600 NETBALL GOALS Q52 Q52/610 RUGBY POSTS Q52 Q52/620 SKATE EQUIPMENT Q52 Q52/623 SKATE PIPES Q52 Q52/627 SKATE PLATFORMS Q52 Q52/630 SKATE RAILS Q52 Q52/633 SKATE RAMPS Q52 Q52/640 TENNIS NET Q52 Q52/650 VOLLEYBALL NET Q52 Q52/660 SPATIAL NETWORK EQUIPMENT Q52 Q52/670 EQUESTRIAN EQUIPMENT Q52 Q52/710 PLAY EQUIPMENT INSTALLATION GENERALLY Q52 Q52/720 CONCRETE FOUNDATIONS GENERALLY Q52 Q52/725 SETTING COMPONENTS IN CONCRETE Q52 Q52/730 SETTING COMPONENTS IN EARTH Q52 Q52/740 PRESERVATIVE TREATED TIMBER Q52 Q52/750 DAMAGE TO GALVANIZED SURFACES Q52 Q52/760 SITE PAINTING Q52 Q52/910 INSPECTION Q52 Q52/920 CLEANING Q52 Q52/930 TESTING Q52 Q52/940 LABELS Q52 Q52/950 DOCUMENTATION Q52 Q52/960 SPARES Q52 Q52/970 OPERATING TOOLS Q52 Q52/980 RETENSIONING ROPES Q52 Q55 EXTERNAL DECKS, BOARDWALKS AND BRIDGES Q Q55/10 INFORMATION TO BE PROVIDED WITH TENDER Q55 Q55/110 DECK Q55 Q55/120 BOARDWALK Q55 Q55/130 FOOTBRIDGE Q55 Q55/140 HARD LANDSCAPING MATERIALS SPECIFICATION Q55 Q55/215 CONTRACTOR'S DESIGN Q55 Q55/217 STRUCTURAL DESIGN PROVIDED Q55 Q55/305 TIMBER PROCUREMENT Q55 Q55/310 STRUCTURAL SOFTWOOD (GRADED DIRECT TO STRENGTH CLASS) Q55 Q55/320 STRUCTURAL SOFTWOOD (STRENGTH CLASS NOT SPECIFIED) Q55 Q55/330 STRUCTURAL HARDWOOD (GRADED DIRECT TO STRENGTH CLASS) Q55 Q55/340 STRUCTURAL HARDWOOD (STRENGTH CLASS NOT SPECIFIED) Q55 Q55/350 STRUCTURAL STEEL Q55 Q55/355 STRUCTURAL STEEL Q55 Q55/370 COMPOSITE SECTIONS Q55 Q55/380 DECK BOARDS Q55 Q55/390 GUARDING Q55 Q55/395 SUPPORT PEDESTALS Q55 Q55/400 PROPRIETARY FOOTBRIDGE Q55 Q55/410 APPLIED SLIP RESISTANT ACCESSORIES Q55 Q55/510 FABRICATION GENERALLY Q55 Q55/610 LOADING Q55 Q55/620 CONCRETE FOUNDATIONS GENERALLY Q55 Q55/630 SETTING COMPONENTS IN CONCRETE Q55 Q55/640 SETTING COMPONENTS IN EARTH Q55 Q55/650 DRIVEN POSTS Q55 Q55/655 ERECTION OF PREFABRICATED TIMBER STRUCTURES ON PREPARED BASES Q55 Q55/657 INSTALLATION OF PEDESTALS Q55 Q55/660 PRESERVATIVE TREATED TIMBER Q55 Q55/665 INSTALLATION GENERALLY Q55 Q55/670 INSTALLATION OF SURFACING Q55 Q55/672 INSTALLATION OF SLIP RESISTANT PRODUCTS Q55 Q55/680 SITE PAINTING AND STAINING Q55 Q55/950 DOCUMENTATION Q55 R DISPOSAL SYSTEMS R10 RAINWATER DRAINAGE SYSTEMS R R10/110 GRAVITY RAINWATER DRAINAGE SYSTEM R10 R10/121 SIPHONIC RAINWATER DRAINAGE SYSTEM R10 R10/130 PRESSURE-ASSISTED RAINWATER DRAINAGE SYSTEM R10 R10/210 DESIGN R10 R10/221 COLLECTION AND DISTRIBUTION OF RAINWATER R10 R10/230 DESIGN PARAMETERS - GENERAL R10 R10/241 DESIGN PARAMETERS - SIPHONIC RAINWATER DRAINAGE SYSTEM R10 R10/250 DESIGN PARAMETERS - PRESSURE-ASSISTED DRAINAGE SYSTEM R10 R10/311 ALUMINIUM GUTTERS R10 R10/315 CAST IRON GUTTERS R10 R10/321 COMBINED FASCIA, SOFFIT AND GUTTER R10 R10/325 COMPOSITE GUTTERS R10 R10/330 COPPER GUTTERS R10 R10/332 CONTINUOUSLY HOT DIP COATED STEEL GUTTERS R10 R10/335 GALVANIZED STEEL GUTTERS R10 R10/340 GRP GUTTERS R10 R10/345 GUTTER LININGS R10 R10/350 PVC-U GUTTERS R10 R10/355 ZINC GUTTERS R10 R10/360 SEALANT FOR GUTTERS R10 R10/365 PROPRIETARY RAINWATER OUTLETS R10 R10/370 ALUMINIUM PIPEWORK R10 R10/375 CAST IRON PIPEWORK - FLEXIBLE COUPLINGS R10 R10/380 CAST IRON PIPEWORK - SPIGOT AND SOCKET R10 R10/385 CAST IRON PIPEWORK - SPIGOT AND SOCKET - SEALED R10 R10/390 COPPER PIPEWORK R10 R10/395 HOT DIP COATED STEEL PIPEWORK - PRESSED R10 R10/400 GALVANIZED STEEL PIPEWORK - THREADED R10 R10/410 GRP PIPEWORK R10 R10/415 HDPE PIPEWORK FOR INTERNAL USE R10 R10/420 PVC-U PIPEWORK - EXTERNAL R10 R10/425 PVC-U PIPEWORK - SEALED R10 R10/431 STAINLESS STEEL PIPEWORK R10 R10/437 ZINC PIPEWORK R10 R10/440 ANTICLIMB RAINWATER PIPE COVERS R10 R10/445 INSULATION TO INTERNAL GUTTERS R10 R10/450 INSULATION TO INTERNAL PIPELINES R10 R10/455 MASKING PLATES R10 R10/460 RAINWATER COLLECTOR UNITS R10 R10/465 RAINWATER STORAGE TANKS R10 R10/510 GALVANIZED STEEL PIPEWORK - PREFABRICATED ASSEMBLIES R10 R10/600 PREPARATION R10 R10/605 INSTALLATION GENERALLY R10 R10/610 FIXING AND JOINTING GUTTERS R10 R10/615 SETTING OUT EAVES GUTTERS - TO FALLS R10 R10/616 SETTING OUT EAVES GUTTERS - LEVEL R10 R10/620 INSTALLING COMBINED FASCIA, SOFFIT AND GUTTER SYSTEM R10 R10/625 INSTALLING PREFORMED GUTTER LININGS R10 R10/630 INSTALLING RAINWATER OUTLETS R10 R10/635 FIXING PIPEWORK R10 R10/640 FIXING VERTICAL PIPEWORK R10 R10/645 FIXING LOW GRADIENT PIPEWORK R10 R10/650 JOINTING PIPEWORK AND GUTTERS R10 R10/655 JOINTING INTERNAL PIPEWORK R10 R10/660 JOINTING EXTERNAL PIPEWORK R10 R10/665 INSTALLING PREFABRICATED GALVANIZED STEEL PIPEWORK R10 R10/670 INSTALLING FULL-BORE FLOW DRAINAGE PIPEWORK R10 R10/675 CUTTING COATED PIPEWORK AND GUTTERS R10 R10/680 FIXING INSULATION TO INTERNAL PIPELINES AND GUTTERS R10 R10/685 IDENTIFICATION OF INTERNAL RAINWATER PIPEWORK R10 R10/690 ELECTRICAL CONTINUITY - PIPEWORK R10 R10/695 ELECTRICAL CONTINUITY - GUTTERS R10 R10/700 ACCESS FOR TESTING AND MAINTENANCE R10 R10/900 TESTING GENERALLY R10 R10/905 INTERNAL PIPEWORK TEST - ENGLAND, WALES, IRELAND AND NORTHERN IRELAND R10 R10/906 INTERNAL PIPEWORK TEST - SCOTLAND R10 R10/910 GUTTER TEST R10 R10/915 MAINTENANCE INSTRUCTIONS R10 R10/920 IMMEDIATELY BEFORE HANDOVER R10 R11 ABOVE GROUND FOUL DRAINAGE SYSTEMS R R11/115 ABOVE GROUND FOUL DRAINAGE SYSTEM R11 R11/210 DESIGN R11 R11/220 COLLECTION AND DISTRIBUTION OF FOUL WATER R11 R11/310 FLOOR CHANNELS R11 R11/315 FLOOR DRAINS R11 R11/320 ABS PIPEWORK R11 R11/325 BOROSILICATE GLASS PIPEWORK R11 R11/330 CAST IRON PIPEWORK - FLEXIBLE COUPLINGS R11 R11/335 CAST IRON PIPEWORK - SPIGOT AND SOCKET R11 R11/340 COPPER PIPEWORK R11 R11/345 HDPE PIPEWORK R11 R11/350 MUPVC OR PVC-C PIPEWORK R11 R11/355 POLYPROPYLENE PIPEWORK R11 R11/365 PVC-U PIPEWORK R11 R11/366 PVC-U PIPEWORK 82.4 MM OD R11 R11/370 STAINLESS STEEL PIPEWORK R11 R11/375 AIR ADMITTANCE VALVES R11 R11/380 GREASE TRAPS AND CONVERTERS R11 R11/383 INSULATION TO INTERNAL PIPELINE R11 R11/385 MASKING PLATES R11 R11/390 RODDING EYES R11 R11/400 PAINT FOR CUT ENDS OF CAST IRON PIPES R11 R11/510 COPPER PIPEWORK - PREFABRICATED ASSEMBLIES R11 R11/530 GALVANIZED STEEL PIPEWORK - PREFABRICATED ASSEMBLIES R11 R11/601 INSTALLATION GENERALLY R11 R11/605 PIPE ROUTES R11 R11/610 FIXING PIPEWORK R11 R11/615 FIXING VERTICAL PIPEWORK R11 R11/620 FIXING LOW GRADIENT PIPEWORK R11 R11/625 JOINTING FLOOR CHANNELS R11 R11/630 JOINTING PIPEWORK - GENERALLY R11 R11/635 JOINTING PIPEWORK - BOROSILICATE GLASS R11 R11/640 JINTING PIPEWORK - CAST IRON - FLEXIBLE COUPLINGS R11 R11/645 JOINTING PIPEWORK - CAST IRON - SPIGOT AND SOCKET R11 R11/650 JOINTING PIPEWORK - COPPER R11 R11/655 JOINTING PIPEWORK - HDPE AND POLYPROPYLENE R11 R11/660 JOINTING PIPEWORK - ABS, MUPVC, PVC-C AND PVC-U R11 R11/665 JOINTING TO COPPER PREFABRICATED PIPEWORK ASSEMBLIES R11 R11/670 JOINTING TO GALVANIZED STEEL PREFABRICATED PIPEWORK ASSEMBLIES R11 R11/675 COATED PIPES R11 R11/680 ELECTRICAL CONTINUITY R11 R11/685 IDENTIFICATION OF INTERNAL FOUL DRAINAGE PIPEWORK R11 R11/690 IDENTIFICATION OF INTERNAL GREY WATER DRAINAGE PIPEWORK R11 R11/695 DISCHARGE AND VENTILATION STACKS R11 R11/700 INSTALLING AIR ADMITTANCE VALVES R11 R11/703 FIXING INSULATION TO INTERNAL PIPELINES R11 R11/705 ACCESS FOR TESTING AND MAINTENANCE R11 R11/900 TESTING GENERALLY R11 R11/905 PIPEWORK AIRTIGHTNESS TEST R11 R11/910 SIPHONAGE AND BACK PRESSURE TESTS R11 R11/915 PREHANDOVER CHECKS R11 R11/920 SUBMITTALS R11 R12 BELOW GROUND DRAINAGE SYSTEMS R R12/110 BELOW GROUND DRAINAGE SYSTEMS R12 R12/114 GROUNDWATER PRESSURE RELIEF DRAINAGE SYSTEMS - BLANKET DRAINS R12 R12/116 GROUNDWATER PRESSURE RELIEF DRAINAGE SYSTEMS - FILTER DRAINS R12 R12/118 GROUNDWATER PRESSURE RELIEF DRAINAGE SYSTEMS - SHEET FIN DRAINS R12 R12/120 SOAKAWAY SYSTEMS - PRECAST CONCRETE R12 R12/122 SOAKAWAY SYSTEMS - PLASTICS UNITS R12 R12/124 SOAKAWAY SYSTEMS - GRANULAR FILL R12 R12/127 PRIVATE PACKAGED SEPTIC TANK SYSTEMS R12 R12/130 PRIVATE PACKAGED SEWAGE TREATMENT SYSTEMS R12 R12/135 PRIVATE PACKAGED PUMPING STATIONS AND PRESSURE PIPELINE SYSTEMS R12 R12/211 DESIGN - BELOW GROUND DRAINAGE SYSTEMS R12 R12/215 DESIGN - GROUNDWATER PRESSURE RELIEF DRAINAGE SYSTEMS R12 R12/221 DESIGN - SOAKAWAY SYSTEMS R12 R12/225 DESIGN - PRIVATE PACKAGED SEPTIC TANK SYSTEMS R12 R12/231 DESIGN - PRIVATE PACKAGED SEWAGE TREATMENT SYSTEMS R12 R12/235 DESIGN - PRIVATE PACKAGED PUMPING STATION SYSTEMS R12 R12/311 ADAPTORS TO CLAY DRAINAGE R12 R12/312 ADAPTORS TO PLASTICS DRAINAGE R12 R12/313 ONE PIECE GULLIES R12 R12/315 ONE PIECE GULLIES AND COVERS R12 R12/317 COMPOSITE GULLIES R12 R12/327 RAINWATER FILTER AND COLLECTOR UNITS R12 R12/329 PIPES, BENDS AND JUNCTIONS - SUPPLY R12 R12/332 PIPES, BENDS AND JUNCTIONS - CAST IRON - DUCTILE R12 R12/334 PIPES, BENDS AND JUNCTIONS - CAST IRON - GREY R12 R12/336 PIPES, BENDS AND JUNCTIONS - CLAY - FLEXIBLE JOINTS R12 R12/338 PIPES, BENDS AND JUNCTIONS - CLAY - RIGID JOINTS R12 R12/342 PIPES, BENDS AND JUNCTIONS - CONCRETE R12 R12/344 PIPES, BENDS AND JUNCTIONS - PLASTICS - STRUCTURED WALL R12 R12/346 PIPES, BENDS AND JUNCTIONS – PVC-U – SOLID WALL R12 R12/348 PIPES, BENDS AND JUNCTIONS - POLYPROPYLENE R12 R12/352 ACCESS POINTS - PLASTICS R12 R12/355 ANTIFLOOD VALVES R12 R12/357 CONNECTORS - SADDLE R12 R12/359 FLEXIBLE COUPLINGS R12 R12/361 FRESH AIR INLETS R12 R12/365 PUDDLE FLANGES R12 R12/367 RAT BARRIERS R12 R12/369 RESIN CEMENT MORTAR FOR JOINTING RIGID CLAY PIPELINES R12 R12/371 RODDING POINTS R12 R12/373 ROOT BARRIERS R12 R12/375 SEALED ACCESS FITTINGS R12 R12/379 WARNING MARKER TAPES R12 R12/401 INSPECTION CHAMBERS - PLASTICS R12 R12/407 MANHOLES AND INSPECTION CHAMBERS - CONCRETE R12 R12/409 MANHOLES - CONCRETE - ADDITIONAL COMPONENTS FOR DEEP MANHOLES R12 R12/412 MANHOLES AND INSPECTION CHAMBERS - PLASTICS R12 R12/419 GREASE TRAPS AND CONVERTERS R12 R12/421 OIL AND PETROL SEPARATOR UNITS - PLASTICS R12 R12/433 MANHOLE CHANNELS AND BRANCHES - CONVENTIONAL R12 R12/435 MANHOLE CHANNELS AND BRANCHES - PREFORMED PLASTICS R12 R12/437 VORTEX FLOW CONTROL UNITS R12 R12/439 MANHOLE STEPS R12 R12/444 SEALING FOR CONCRETE MANHOLES - BITUMINOUS STRIPS R12 R12/446 SEALING FOR CONCRETE MANHOLES - MORTAR R12 R12/448 SEALING FOR CONCRETE MANHOLES - SEALANT R12 R12/460 STORAGE TANKS R12 R12/462 STORAGE TANKS - FOUL WATER R12 R12/464 MODULAR STORMWATER ATTENUATION UNITS R12 R12/468 PRECAST CONCRETE COVER SLABS R12 R12/471 ACCESS COVERS AND FRAMES R12 R12/473 ACCESS COVERS AND FRAMES - PRECAST CONCRETE SEATINGS R12 R12/475 ACCESS LADDERS R12 R12/481 CONCRETE (FOAMED) R12 R12/483 CONCRETE (GENERAL) R12 R12/485 CONCRETE (STRUCTURAL) R12 R12/487 CONCRETE (ADOPTABLE MANHOLE BENCHINGS AND SURROUNDS) R12 R12/489 CONCRETE (ADOPTABLE MANHOLE BENCHING TOPPING) R12 R12/492 GEOTEXTILE MEMBRANES - FILTER R12 R12/494 GEOTEXTILE MEMBRANES - IMPERVIOUS R12 R12/496 GRANULAR MATERIAL - NATURAL R12 R12/497 GRANULAR MATERIAL - MANUFACTURED R12 R12/498 GRANULAR SUB-BASE MATERIAL R12 R12/510 VERMIN GRATINGS FOR OUTFALLS AND OUTLET HEADWALLS R12 R12/610 STRIPPING OUT R12 R12/611 EXISTING DRAINS R12 R12/613 EXCAVATED MATERIAL R12 R12/616 SELECTED FILL FOR BACKFILLING R12 R12/623 LOWER PART OF TRENCH - GENERAL R12 R12/625 LOWER PART OF TRENCH - TRANSITION DEPTH R12 R12/631 TYPE OF SUBSOIL R12 R12/635 FORMATION FOR BEDDINGS R12 R12/641 PIPES AT DIFFERENT LEVELS IN COMMON TRENCH R12 R12/651 CLASS A SUPPORT R12 R12/653 CLASS B SUPPORT R12 R12/655 CLASS D BED R12 R12/657 CLASS F BEDDING R12 R12/659 CLASS N BEDDING R12 R12/661 CLASS O SUPPORT R12 R12/663 CLASS P SUPPORT R12 R12/665 CLASS Q SURROUND R12 R12/667 CLASS S SURROUND R12 R12/669 CLASS T SURROUND R12 R12/671 CLASS V SURROUND R12 R12/673 CLASS W SURROUND R12 R12/676 CLASS Y SURROUND R12 R12/678 CLASS Z SURROUND R12 R12/680 CONCRETE SURROUND FOR PIPE RUNS NEAR FOUNDATIONS R12 R12/683 LAYING PIPELINES R12 R12/685 JOINTING PIPELINES R12 R12/687 CONCRETE SURROUND FOR CROSSOVERS R12 R12/689 PIPELINES PASSING THROUGH STRUCTURES R12 R12/691 BENDS AT BASE OF SOIL STACKS R12 R12/693 DIRECT CONNECTION OF GROUND FLOOR WCS TO DRAINS R12 R12/695 BACKDROP PIPES OUTSIDE MANHOLE WALLS R12 R12/697 INSTALLING FLEXIBLE COUPLINGS R12 R12/699 CONNECTIONS TO SEWERS R12 R12/705 INITIAL TESTING OF PIPELINES R12 R12/711 TRENCH SUPPORTS R12 R12/713 INSTALLING ROOT BARRIERS R12 R12/715 BACKFILLING TO PIPELINES R12 R12/718 BACKFILLING OVER CONCRETE R12 R12/720 BACKFILLING UNDER ROADS AND PAVINGS R12 R12/722 PUBLIC ROADS AND PAVINGS - E&W, SCOT R12 R12/724 PUBLIC ROADS AND PAVINGS - NI R12 R12/726 FOAMED CONCRETE BACKFILL R12 R12/728 LAYING WARNING MARKER TAPES R12 R12/732 TEMPORARY BRIDGES R12 R12/734 INSTALLING ACCESS POINTS AND GULLIES R12 R12/736 INSTALLING RODDING POINTS R12 R12/741 INSTALLING INSPECTION CHAMBERS - PLASTICS R12 R12/743 INSTALLING CONCRETE MANHOLES R12 R12/745 INSTALLING GREASE TRAPS AND CONVERTERS R12 R12/747 INSTALLING OIL AND PETROL SEPARATOR UNITS R12 R12/750 INSTALLING VORTEX FLOW CONTROL UNITS R12 R12/753 FIXING MANHOLE STEPS R12 R12/755 JOINTING CONCRETE MANHOLE CHAMBER SECTIONS R12 R12/757 LAYING CONVENTIONAL CHANNELS, BRANCHES AND BENCHING R12 R12/759 LAYING PREFORMED PLASTICS CHANNELS, BRANCHES AND BENCHING R12 R12/761 LAYING SEALED ACCESS FITTINGS, BRANCHES AND BENCHING R12 R12/766 INSTALLING UNDERGROUND STORAGE TANK UNITS R12 R12/771 INSTALLING OUTFALLS R12 R12/773 INSTALLING ACCESS COVERS AND FRAMES R12 R12/776 EXPOSED OPENINGS IN INSPECTION CHAMBERS, ACCESS POINTS, FITTINGS AND EQUIPMENT R12 R12/901 REMOVAL OF DEBRIS AND CLEANING R12 R12/903 TEMPORARY MEASURES R12 R12/911 TESTING AND INSPECTION R12 R12/921 FINAL TESTING OF PRIVATE GRAVITY DRAINS AND SEWERS UP TO DN 300 R12 R12/931 FINAL TESTING OF ADOPTABLE AND LARGE PRIVATE SEWERS R12 R12/941 WATER TESTING OF MANHOLES AND INSPECTION CHAMBERS R12 R12/951 TESTING OF ANCILLARY COMPONENTS R12 R12/971 CCTV INSPECTION OF PRIVATE PIPELINES R12 R12/976 CCTV INSPECTION OF ADOPTABLE PIPELINES R12 R12/978 LIFTING KEYS R12 R12/980 INSTRUCTIONS R12 R13 LAND DRAINAGE R R13/100 EXISTING DRAINS AND WATERCOURSES R13 R13/103 SEQUENCE OF WORK R13 R13/106 IN SITU CONCRETE (GENERAL) R13 R13/201 FILTER DRAINS R13 R13/205 FILTER DRAINS WITH GEOTEXTILE TRENCH LINING R13 R13/211 FILTER DRAINS WITH PIPE R13 R13/215 FILTER DRAINS WITH GEOTEXTILE-WRAPPED PIPE R13 R13/220 FILTER DRAINS WITH PIPE AND GEOTEXTILE TRENCH LINING R13 R13/225 NARROW SLOT FIN DRAINS R13 R13/227 FIN DRAINS WITH PIPE R13 R13/230 MOLE DRAINAGE R13 R13/232 SUBSOILING R13 R13/235 TRENCHLESS DRAINS R13 R13/237 SAND OR GRAVEL SLITTING R13 R13/239 SAND GROOVING R13 R13/241 PIPE DRAINS R13 R13/245 PIPE DRAINS WITH GEOTEXTILE WRAPPING R13 R13/250 DRAINAGE BLANKETS R13 R13/350 LAYING PIPES R13 R13/401 CULVERTED DITCH R13 R13/405 PRECAST CONCRETE PIPE CULVERTS R13 R13/411 PRECAST CONCRETE BOX CULVERTS R13 R13/500 TOPSOILING R13 R13/505 EXCAVATION R13 R13/515 EXISTING LIVE LAND DRAINS R13 R13/520 FORMATION FOR BEDS PR PIPES R13 R13/525 GRANULAR BEDS R13 R13/530 GRANULAR SURROUND AND BACKFILL - SUBSOIL DRAINS R13 R13/531 GRANULAR SURROUND AND BACKFILL - SUBSOIL DRAINS - PRECISION GRADED R13 R13/540 GRANULAR SURROUND AND BACKFILL - SURFACE WATER DRAINS R13 R13/541 GRANULAR SURROUND AND BACKFILL - SURFACE WATER DRAINS - PRECISION GRADED R13 R13/546 SELECTED AS-DUG SURROUND AND BACKFILL R13 R13/555 GRANULAR BACKFILLING TO DRAINS WITH PIPES R13 R13/560 GRANULAR BACKFILLING TO DRAINS WITHOUT PIPES R13 R13/565 BACKFILLING WITH AS-DUG MATERIAL R13 R13/570 GEOTEXTILE TRENCH LINING R13 R13/600 BRICK SILT TRAP INSPECTION CHAMBERS AND MANHOLES R13 R13/605 PRECAST CONCRETE SILT TRAP INSPECTION CHAMBERS AND MANHOLES R13 R13/615 SMALL VITRIFIED CLAY SILT TRAPS R13 R13/620 GRANULAR FILL SOAKAWAYS R13 R13/625 PRECAST CONCRETE SOAKAWAYS R13 R13/630 STORAGE TANKS FOR GROUND WATER R13 R13/640 CAST IRON ACCESS COVERS AND SEATING R13 R13/700 OUTLET HEADWALLS R13 R13/710 INLET HEADWALLS R13 R13/720 PLAIN PIPE OUTFALLS TO OPEN WATERCOURSES R13 R13/800 CLEANING R13 R13/810 INSPECTION OF TRENCHLESS DRAINS R13 R16 GROUNDWATER PRESSURE RELIEF DRAINAGE R R16/305 BELOW GROUND DRAINAGE SYSTEMS - PRODUCTS R16 R16/330 PIPES, BENDS AND JUNCTIONS - CLAY PERFORATED R16 R16/335 PIPES, BENDS AND JUNCTIONS - PLASTICS -STRUCTURED WALL PERFORATED R16 R16/340 PIPES, BENDS AND JUNCTIONS - PVC-U - CORRUGATED PERFORATED R16 R16/345 PIPES, BENDS AND JUNCTIONS - PVC-U - SOLID WALL PERFORATED R16 R16/350 SILT TRAPS R16 R16/360 POLYETHYLENE SHEET FOR FILTER DRAIN CAPPING R16 R16/370 GEOTEXTILE MEMBRANE FOR BLANKET DRAINS R16 R16/375 GEOTEXTILE MEMBRANE FOR FILTER DRAIN CAPPINGS R16 R16/380 SHEET FIN DRAINS R16 R16/605 BELOW GROUND DRAINAGE SYSTEMS - EXECUTION R16 R16/630 LAYING PERFORATED PIPES R16 R16/640 CLASS X BEDDING AND SURROUND R16 R16/645 LAYING GEOTEXTILE MEMBRANES - LARGE HORIZONTAL AREAS R16 R16/650 LAYING FILTER DRAIN CAPPINGS R16 R16/652 LAYING PRESSURE RELIEF BLANKET DRAINS R16 R16/655 LAYING SHEET FIN DRAINS R16 R16/660 INSTALLING SILT TRAPS R16 R16/665 BACKFILLING WITH AS-DUG MATERIAL R16 R17 SOAKAWAY, SEPTIC TANK AND SEWAGE TREATMENT UNITS R R17/305 BELOW GROUND DRAINAGE SYSTEMS - PRODUCTS R17 R17/310 PRECAST CONCRETE SOAKAWAY UNITS R17 R17/312 PRECAST CONCRETE SOAKAWAY UNITS - ADDITIONAL COMPONENTS FOR DEEP SOAKAWAYS R17 R17/315 MODULAR PLASTICS SOAKAWAY UNITS R17 R17/320 PRIVATE PACKAGED SEPTIC TANK UNITS R17 R17/325 PRIVATE PACKAGED SEWAGE TREATMENT UNITS R17 R17/330 DISTRIBUTION AND SAMPLING CHAMBERS R17 R17/335 PIPES, BENDS AND JUNCTIONS - CLAY PERFORATED R17 R17/340 PIPES, BENDS AND JUNCTIONS - PLASTICS - STRUCTURED WALL PERFORATED R17 R17/345 PIPES, BENDS AND JUNCTIONS - PVC-U - CORRUGATED PERFORATED R17 R17/350 PIPES, BENDS AND JUNCTIONS - PVC-U - SOLID WALL PERFORATED R17 R17/355 GRANULAR MATERIAL - RUBBLE R17 R17/360 GEOTEXTILE MEMBRANE FOR GRANULAR FILL SOAKAWAYS R17 R17/362 GEOTEXTILE MEMBRANE FOR PRECAST CONCRETE SOAKAWAYS R17 R17/365 GEOTEXTILE MEMBRANE FOR SEPTIC TANK DRAINAGE FIELDS R17 R17/370 POLYETHYLENE SHEET R17 R17/375 VENT PIPES FOR SEPTIC TANKS AND SEWAGE TREATMENT UNITS R17 R17/380 CABLE DUCTS FOR SEWAGE TREATMENT UNITS R17 R17/605 BELOW GROUND DRAINAGE SYSTEMS - EXECUTION R17 R17/615 INSTALLING PRECAST CONCRETE SOAKAWAYS R17 R17/625 SOAKAWAYS - GRANULAR FILL R17 R17/630 INSTALLING SEPTIC TANK AND SEWAGE TREATMENT UNITS R17 R17/635 INSTALLING DISTRIBUTION AND SAMPLING CHAMBERS R17 R17/640 SEPTIC TANK DRAINAGE FIELDS R17 R17/645 LAYING PERFORATED PIPES R17 R17/647 LAYING CABLE DUCTS R17 R17/650 BACKFILLING WITH AS-DUG MATERIAL R17 R17/910 COMMISSIONING OF SEWAGE TREATMENT UNITS R17 R18 PUMPING STATIONS AND PRESSURE PIPELINES R R18/305 BELOW GROUND DRAINAGE SYSTEMS - PRODUCTS R18 R18/310 PRIVATE PACKAGED PUMPING STATIONS R18 R18/315 PRESSURE PIPES, BENDS AND JUNCTIONS - CAST IRON - DUCTILE R18 R18/320 PRESSURE PIPES, BENDS AND JUNCTIONS - POLYETHYLENE R18 R18/325 PRESSURE PIPES, BENDS AND JUNCTIONS - PVC-A R18 R18/330 PRESSURE PIPES, BENDS AND JUNCTIONS - PVC-U R18 R18/335 AIR RELEASE VALVES TO PRESSURE PIPELINES R18 R18/340 WASHOUT VALVES TO PRESSURE PIPELINES R18 R18/350 CABLE DUCTS FOR PRIVATE PACKAGED PUMPING STATIONS R18 R18/605 BELOW GROUND DRAINAGE SYSTEMS - EXECUTION R18 R18/620 INSTALLING PRIVATE PACKAGED PUMPING STATIONS R18 R18/630 ANCHORAGES TO PRESSURE PIPELINES R18 R18/640 LAYING CABLE DUCTS R18 R18/910 WATER TESTING OF PRIVATE PRESSURE PIPELINES R18 S PIPED SUPPLY SYSTEMS S10 HOT AND COLD WATER SUPPLY SYSTEMS S S10/110 INCOMING WATER SUPPLY S10 S10/120 COLD WATER SUPPLY SYSTEM S10 S10/130 PUMPED COLD WATER SUPPLY SYSTEM S10 S10/140 INSTANTANEOUS HOT WATER SUPPLY SYSTEM S10 S10/150 DIRECT HOT WATER STORAGE SUPPLY SYSTEM S10 S10/160 INDIRECT HOT WATER STORAGE SUPPLY SYSTEM S10 S10/210 DESIGN AND DETAILING S10 S10/215 INCOMING WATER ANALYSIS S10 S10/220 COLD WATER SUPPLY S10 S10/230 INSTANTANEOUS HOT WATER SUPPLY S10 S10/240 CENTRALIZED HOT WATER STORAGE SYSTEM S10 S10/250 PIPELINE SIZES S10 S10/255 DRAW OFF REQUIREMENTS S10 S10/260 COMBUSTION AIR SUPPLY TO GAS APPLIANCES S10 S10/310 DEZINCIFICATION S10 S10/320 WATER METERS S10 S10/350 INSTANTANEOUS SHOWER UNITS, ELECTRIC S10 S10/360 INSTANTANEOUS WATER HEATERS, ELECTRIC S10 S10/370 INSTANTANEOUS WATER HEATERS, GAS FIRED S10 S10/375 INSTANTANEOUS WATER HEATERS, PACKAGED PLATE HEAT EXCHANGERS S10 S10/376 BUFFER VESSEL S10 S10/380 DIRECT HOT WATER STORAGE CYLINDERS S10 S10/390 DIRECT INSULATED COMBINATION UNITS S10 S10/400 IMMERSION HEATERS S10 S10/410 INSULATING JACKETS FOR HWS CYLINDERS S10 S10/420 STORAGE WATER HEATERS, ELECTRIC S10 S10/430 STORAGE WATER HEATERS, GAS FIRED S10 S10/435 DUAL COIL HOT WATER STORAGE CYLINDERS S10 S10/440 INDIRECTLY HEATED UNVENTED HOT WATER STORAGE S10 S10/450 INDIRECT HOT WATER STORAGE CYLINDERS, DOUBLE FEED S10 S10/455 INDIRECT HOT WATER STORAGE CYLINDERS, SINGLE FEED S10 S10/460 DOUBLE FEED INDIRECT INSULATED COMBINATION UNITS S10 S10/465 SINGLE FEED INDIRECT INSULATED COMBINATION UNITS S10 S10/480 FLUSH CONTROL DEVICES S10 S10/490 WATER COOLERS S10 S10/610 STRIPPING OUT HOT AND COLD WATER SYSTEMS S10 S10/620 INSTALLATION OF HOT AND COLD WATER SYSTEMS GENERALLY S10 S10/630 INSTALLING WATER METERS S10 S10/650 INSTALLING GAS FIRED WATER HEATERS S10 S10/660 INSTALLING UNVENTED HOT WATER STORAGE DISCHARGE PIPES S10 S10/680 INSTALLING BALANCED FLUE TERMINALS S10 S10/690 HYDRAULIC PRESSURE TESTING OF HOT AND COLD WATER SUPPLY SYSTEMS S10 S10/810 DOCUMENTATION S10 S10/820 SPARES S10 S10/830 OPERATING TOOLS S10 S10/840 MAINTENANCE S10 S12 WATER TREATMENT EQUIPMENT S S12/310 ELECTRODIALYSIS UNITS S12 S12/320 FILTRATION UNITS S12 S12/330 ION EXCHANGE DEMINERALIZATION UNITS S12 S12/340 NITRATE REMOVAL DEVICES FOR DRINKING WATER S12 S12/350 ION EXCHANGE SOFTENING UNITS S12 S12/360 MAGNETIC WATER CONDITIONERS S12 S12/370 REVERSE OSMOSIS UNITS S12 S12/380 ULTRA-VIOLET LIGHT DISINFECTION UNITS S12 S12/400 SPARES AND CONSUMABLES S12 S12/610 INSTALLING ION EXCHANGE DEMINERALIZATION UNIT S12 S12/620 INSTALLING ION EXCHANGE SOFTENING UNITS S12 S12/630 INSTALLING WATER CONDITIONING DEVICES S12 S14 IRRIGATION S S14/110 IRRIGATION SYSTEM S14 S14/210 DESIGN AND DETAILING S14 S14/220 PIPELINE DESIGN S14 S14/230 DISCHARGE REQUIREMENTS S14 S14/310 DEZINCIFICATION S14 S14/320 WATER METERS S14 S14/325 BACKFLOW PREVENTION DEVICES S14 S14/330 WATER STORAGE TANKS S14 S14/345 PUMP SELECTION S14 S14/346 PUMPS S14 S14/362 COPPER PIPELINE FOR GENERAL USE S14 S14/365 COPPER PIPELINE FOR UNDERGROUND USE S14 S14/368 POLYETHYLENE PIPELINE FOR UNDERGROUND USE S14 S14/372 THERMOPLASTICS PIPELINE S14 S14/378 INSULATION TO EXTERNAL SUPPLY PIPELINES S14 S14/382 VALVES GENERALLY S14 S14/383 STOP VALVES AND DRAW-OFF TAPS FOR ABOVE GROUND USE S14 S14/384 STOP VALVES FOR BELOW GROUND USE S14 S14/392 FLOW REDUCING SERVICING VALVES S14 S14/393 PRESSURE REGULATORS S14 S14/394 SOLENOID VALVES S14 S14/395 FILTERS S14 S14/412 BUBBLER SYSTEMS S14 S14/415 PASSIVE SYSTEM S14 S14/422 POROUS PIPE SYSTEMS S14 S14/430 SPRINKLERS S14 S14/435 TAPE LINES/ DRIPPER SYSTEMS S14 S14/440 CHEMICAL INJECTORS S14 S14/450 CONTROLLERS S14 S14/455 ELECTRONIC TIMERS S14 S14/460 EQUIPMENT ENCLOSURE S14 S14/465 MECHANICAL TIMERS S14 S14/470 PLANT NUTRIENT TANKS S14 S14/475 PRESSURE GAUGE S14 S14/480 VALVE BOXES S14 S14/485 WATER CONDITIONER S14 S14/490 WATER METERING VALVES S14 S14/610 INSTALLATION GENERALLY S14 S14/611 INSTALLATION OF PUMPS S14 S14/612 PIPELINE INSTALLATION S14 S14/613 SUPPORTS FOR COPPER PIPELINES S14 S14/614 SUPPORTS FOR THERMOPLASTICS PIPELINES S14 S14/615 FITTING INSULATION TO EXTERNAL SUPPLY PIPELINES S14 S14/616 JOINTS IN COPPER PIPELINES S14 S14/617 JOINTS IN THERMOPLASTICS PIPELINES S14 S14/618 INSTALLATION OF VALVES S14 S14/630 SERVICE CONNECTIONS S14 S14/910 TESTING S14 S14/911 INSPECTION TESTING S14 S14/912 FLUSHING AND DISINFECTION S14 S14/920 COMMISSIONING S14 S14/930 DOCUMENTATION S14 S14/940 OPERATING TOOLS S14 S14/950 SPARES S14 S15 FOUNTAINS AND WATER FEATURES S S15/110 FABRIC S15 S15/120 WATER SUPPLY S15 S15/130 POWER SUPPLY S15 S15/200 GENERAL DESIGN S15 S15/300 IN SITU GRP LINER S15 S15/310 PREFORMED LINER S15 S15/350 BACKFLOW PREVENTION S15 S15/355 BREAK TANK S15 S15/400 PUMP SELECTION S15 S15/405 DRY PUMP S15 S15/406 SUBMERSIBLE PUMP S15 S15/410 COPPER PIPELINE FOR GENERAL USE S15 S15/411 COPPER PIPELINE FOR UNDERGROUND USE S15 S15/415 POLYETHYLENE PIPELINE FOR UNDERGROUND USE S15 S15/420 SPIRAL PLASTICS HOSE S15 S15/425 STAINLESS STEEL PIPELINE S15 S15/430 THERMOPLASTICS S15 S15/435 PIPELINE INSULATION S15 S15/450 AERATOR S15 S15/455 LAMINAR JET S15 S15/460 NOZZLE S15 S15/470 ULTRASONIC MIST MAKER S15 S15/480 WATERFALLS AND CASCADES S15 S15/500 ANEMOMETER S15 S15/510 OVERFLOW S15 S15/520 PUMP SUPPLY CUTOFF S15 S15/525 VALVES GENERALLY S15 S15/530 VALVES S15 S15/535 WATER LEVEL CONTROL S15 S15/550 BIOAUGMENTATION S15 S15/555 CLARIFIER S15 S15/560 FILTER S15 S15/565 STERILIZER S15 S15/570 STRAINER S15 S15/575 SURFACE SKIMMER S15 S15/580 WATER CONDITIONING UNIT S15 S15/585 DRAIN S15 S15/645 EQUIPMENT ENCLOSURE S15 S15/700 INSTALLATION GENERALLY S15 S15/710 INSTALLATION OF PUMPS S15 S15/720 PIPELINE INSTALLATION S15 S15/721 PIPELINE FIXING S15 S15/722 SUPPORTS FOR COPPER AND STAINLESS STEEL PIPELINES S15 S15/723 SUPPORTS FOR THERMOPLASTICS PIPELINES S15 S15/725 INSTALLATION OF INSULATION TO PIPELINES S15 S15/730 JOINTS IN COPPER AND STAINLESS STEEL PIPELINES: S15 S15/731 JOINTS IN THERMOPLASTICS PIPELINES S15 S15/735 INSTALLATION OF VALVES S15 S15/740 INSTALLATION OF BREAK TANKS S15 S15/745 INSTALLATION OF WATER SOFTENERS S15 S15/910 FLUSHING S15 S15/920 SYSTEM DISINFECTION S15 S15/930 TESTING AND COMMISSIONING OF PIPEWORK S15 S15/936 CLEANING S15 S15/940 DOCUMENTATION S15 S15/950 OPERATING TOOLS S15 S15/960 LABELS S15 S17 WATER RECLAMATION SYSTEMS S S17/110 GREY WATER RECLAMATION SYSTEM S17 S17/120 RAINWATER RECLAMATION SYSTEM S17 S17/210 DESIGN S17 S17/220 GREY WATER RECLAMATION SYSTEM DESIGN PARAMETERS S17 S17/230 RAINWATER RECLAMATION SYSTEM DESIGN PARAMETERS S17 S17/340 MAINS WATER TOP UP CONNECTION S17 S17/370 PUMPS S17 S17/380 WATER METERS S17 S17/390 GREY WATER TREATMENT S17 S17/400 RAINWATER TREATMENT S17 S17/420 CONTROLS S17 S17/610 STRIPPING OUT S17 S17/620 INSTALLING WATER METERS S17 S17/630 INSTALLING GREYWATER SYSTEMS S17 S17/640 INSTALLING RAINWATER HARVESTING SYSTEMS S17 S17/810 TESTING AND SETTING TO WORK S17 S17/820 IDENTIFICATION S17 S17/830 DOCUMENTATION S17 S17/840 SPARES AND CONSUMABLES S17 S17/850 MAINTENANCE S17 S18 SWIMMING POOL WATER TREATMENT SYSTEMS S S18/110 POOL TYPE S18 S18/120 SPA S18 S18/130 SWIMMING POOL WATER TREATMENT SYSTEM S18 S18/210 DESIGN S18 S18/230 DESIGN PARAMETERS S18 S18/240 POOL CIRCULATION S18 S18/310 FLOW METERS S18 S18/320 DOSING UNITS - ALKALINITY S18 S18/330 DOSING UNITS - COAGULANT S18 S18/340 DOSING UNITS - DISINFECTANT S18 S18/350 DOSING UNITS - PH CONTROL S18 S18/360 FILTERS - BASKET S18 S18/370 FILTERS - CARTRIDGE S18 S18/380 FILTERS - PRECOAT S18 S18/390 FILTERS - PRESSURE S18 S18/410 WATER INLETS S18 S18/420 WATER OUTLETS S18 S18/440 SENSORS - DISINFECTANT S18 S18/450 SENSORS - PH VALUE S18 S18/470 STRAINERS S18 S18/610 STRIPPING OUT S18 S18/910 TESTING AND COMMISSIONING S18 S18/920 MICROBIOLOGICAL MONITORING S18 S18/930 DOCUMENTATION S18 S18/940 SPARES AND CONSUMABLES S18 S18/950 MAINTENANCE S18 S20 MEDICAL OXYGEN SUPPLY SYSTEMS S S20/110 MEDICAL OXYGEN SUPPLY SYSTEM S20 S20/210 DESIGN S20 S20/310 PRODUCTS GENERALLY S20 S20/320 LIQUID OXYGEN CYLINDERS S20 S20/330 PRESSURE SWING ADSORPTION (PSA) PLANT S20 S20/340 VACUUM INSULATED EVAPORATOR (VIE) STORAGE VESSELS S20 S20/350 COMPRESSED GAS CYLINDERS S20 S20/360 EMERGENCY SUPPLY MANIFOLDS S20 S20/370 AREA VALVE SERVICE UNITS S20 S20/380 TERMINAL UNITS S20 S20/610 STRIPPING OUT S20 S20/620 INSTALLATION GENERALLY S20 S20/630 INSTALLING LIQUID OXYGEN CYLINDERS S20 S20/640 INSTALLING PRESSURE SWING ADSORPTION PLANT S20 S20/650 INSTALLING VACUUM INSULATED EVAPORATOR STORAGE VESSELS S20 S20/660 INSTALLING COMPRESSED GAS CYLINDERS S20 S20/665 INSTALLING AREA VALVE SERVICE UNITS S20 S20/670 INSTALLING TERMINAL UNITS S20 S20/810 DOCUMENTATION S20 S20/820 SERVICING AND MAINTENANCE S20 S21 MEDICAL NITROUS OXIDE SUPPLY SYSTEMS S S21/110 MEDICAL NITROUS OXIDE SUPPLY SYSTEM S21 S21/210 DESIGN S21 S21/310 PRODUCTS GENERALLY S21 S21/320 COMPRESSED GAS CYLINDERS S21 S21/330 EMERGENCY SUPPLY MANIFOLDS S21 S21/340 AREA VALVE SERVICE UNITS S21 S21/350 TERMINAL UNITS S21 S21/610 STRIPPING OUT S21 S21/620 INSTALLATION GENERALLY S21 S21/630 INSTALLING COMPRESSED GAS CYLINDERS S21 S21/635 INSTALLING AREA VALVE SERVICE UNITS S21 S21/640 INSTALLING TERMINAL UNITS S21 S21/810 DOCUMENTATION S21 S21/820 SERVICING AND MAINTENANCE S21 S22 MEDICAL COMPRESSED AIR SUPPLY SYSTEMS S S22/110 MEDICAL COMPRESSED AIR SUPPLY SYSTEM S22 S22/210 DESIGN S22 S22/310 PRODUCTS GENERALLY S22 S22/320 COMPRESSORS S22 S22/330 COMPRESSED GAS CYLINDERS S22 S22/340 EMERGENCY SUPPLY MANIFOLDS S22 S22/350 PRESSURE REDUCING STATIONS S22 S22/360 AREA VALVE SERVICE UNITS S22 S22/370 TERMINAL UNITS S22 S22/610 STRIPPING OUT S22 S22/620 INSTALLATION GENERALLY S22 S22/630 INSTALLING COMPRESSORS S22 S22/640 INSTALLING COMPRESSED GAS CYLINDERS S22 S22/643 INSTALLATION OF PRESSURE REDUCING STATIONS S22 S22/645 INSTALLING AREA VALVE SERVICE UNITS S22 S22/650 INSTALLING TERMINAL UNITS S22 S22/810 DOCUMENTATION S22 S22/820 SERVICING AND MAINTENANCE S22 S23 MEDICAL VACUUM SYSTEMS S S23/110 MEDICAL VACUUM SYSTEM S23 S23/210 DESIGN S23 S23/310 PRODUCTS GENERALLY S23 S23/320 MEDICAL VACUUM PLANT S23 S23/330 AREA VALVE SERVICE UNITS S23 S23/340 TERMINAL UNITS S23 S23/610 STRIPPING OUT S23 S23/620 INSTALLATION GENERALLY S23 S23/630 INSTALLING MEDICAL VACUUM PLANT S23 S23/635 INSTALLING AREA VALVE SERVICE UNITS S23 S23/640 INSTALLING TERMINAL UNITS S23 S23/810 DOCUMENTATION S23 S23/820 SERVICING AND MAINTENANCE S23 S24 MEDICAL ENTONOX SUPPLY SYSTEMS S S24/110 MEDICAL ENTONOX SUPPLY SYSTEM S24 S24/210 DESIGN S24 S24/310 PRODUCTS GENERALLY S24 S24/320 COMPRESSED GAS CYLINDERS S24 S24/330 EMERGENCY SUPPLY MANIFOLDS S24 S24/340 AREA VALVE SERVICE UNITS S24 S24/350 TERMINAL UNITS S24 S24/610 STRIPPING OUT S24 S24/620 INSTALLATION GENERALLY S24 S24/630 INSTALLING COMPRESSED GAS CYLINDERS S24 S24/635 INSTALLING AREA VALVE SERVICE UNITS S24 S24/640 INSTALLING TERMINAL UNITS S24 S24/810 DOCUMENTATION S24 S24/820 SERVICING AND MAINTENANCE S24 S25 MEDICAL ANAESTHETIC GAS SCAVENGING SYSTEMS S S25/110 MEDICAL ANAESTHETIC GAS SCAVENGING SYSTEM S25 S25/210 DESIGN S25 S25/310 PRODUCTS GENERALLY S25 S25/320 EXHAUSTER UNITS S25 S25/325 AREA VALVE SERVICE UNITS S25 S25/330 TERMINAL UNITS S25 S25/340 REMOTE START SWITCH PANEL S25 S25/350 VACUUM FLOW REGULATING VALVES S25 S25/610 STRIPPING OUT S25 S25/620 INSTALLATION GENERALLY S25 S25/630 INSTALLING EXHAUSTER UNITS S25 S25/640 INSTALLING REMOTE START SWITCH PANELS S25 S25/645 INSTALLING AREA VALVE SERVICE UNITS S25 S25/650 INSTALLING TERMINAL UNITS S25 S25/810 DOCUMENTATION S25 S25/820 SERVICING AND MAINTENANCE S25 S29 MEDICAL GAS EQUIPMENT S S29/310 PRODUCTS GENERALLY S29 S29/320 AREA SERVICE MODULES S29 S29/330 MEDICAL GAS AREA ALARMS S29 S29/340 MEDICAL GAS CENTRAL ALARMS S29 S29/350 HEADWALL BEDHEAD UNITS S29 S29/360 MEDICAL TRUNKING BEDHEAD UNITS S29 S29/370 FLEXIBLE PENDANTS S29 S29/380 MULTI-MOVEMENT PENDANTS S29 S29/390 RETRACTABLE PENDANTS S29 S29/400 RIGID PENDANTS S29 S29/420 COPPER TUBES S29 S29/430 LINE VALVES S29 S29/610 INSTALLATION GENERALLY S29 S29/620 INSTALLING AREA SERVICE MODULES S29 S29/630 INSTALLING AREA ALARMS S29 S29/640 INSTALLING CENTRAL ALARMS S29 S29/650 INSTALLING BEDHEAD UNITS S29 S29/660 INSTALLING RETRACTABLE PENDANTS S29 S29/670 INSTALLING RIGID PENDANTS S29 S29/680 PLANT AND EQUIPMENT IDENTIFICATION S29 S29/810 COMMISSIONING OF MEDICAL GAS SYSTEMS S29 S29/820 INSPECTION AND TEST RECORDS S29 S30 COMPRESSED AIR SUPPLY SYSTEMS S S30/110 COMPRESSED AIR SUPPLY SYSTEM S30 S30/210 DESIGN S30 S30/310 COMPRESSORS S30 S30/320 COMPRESSED GAS CYLINDERS S30 S30/330 AIR PREPARATION UNITS S30 S30/340 BLOW PROTECTORS S30 S30/350 HOSE REEL BALANCERS S30 S30/360 HOSE REELS S30 S30/370 HOSES, COIL S30 S30/375 HOSES, SPIRAL S30 S30/380 PRESSURE REDUCING STATIONS S30 S30/390 AIR RECEIVERS S30 S30/400 DESICCANT DRYERS S30 S30/410 REFRIGERANT DRYERS S30 S30/420 IN LINE FILTERS S30 S30/430 AIR COOLED AFTERCOOLERS S30 S30/440 WATER COOLED AFTERCOOLERS S30 S30/450 OIL/ WATER SEPARATORS S30 S30/460 COUPLINGS S30 S30/610 STRIPPING OUT S30 S30/620 INSTALLING COMPRESSORS S30 S30/630 INSTALLING COMPRESSED GAS CYLINDERS S30 S30/905 TESTING AND COMMISSIONING S30 S30/910 DOCUMENTATION S30 S30/920 MAINTENANCE S30 S32 NATURAL GAS SUPPLY SYSTEMS S S32/110 INCOMING GAS SUPPLY S32 S32/120 NATURAL GAS SUPPLY SYSTEM S32 S32/210 DESIGN S32 S32/220 PIPELINE SIZES S32 S32/310 SECONDARY GAS METERS S32 S32/320 DOMESTIC LOW PRESSURE GAS SUPPLY PIPELINES S32 S32/330 LOW PRESSURE GAS SUPPLY PIPELINES S32 S32/335 INDUSTRIAL GAS SUPPLY PIPELINES S32 S32/340 GAS SOLENOID VALVES S32 S32/350 MECHANICAL SAFETY VALVES S32 S32/360 NON-RETURN VALVES S32 S32/370 GAS BOOSTERS S32 S32/380 GAS FILTERS S32 S32/390 PRESSURE SWITCHES S32 S32/400 SAFETY AND CONTROL DEVICES S32 S32/410 BALL VALVES, MANUALLY OPERATED S32 S32/420 PLUG VALVES, CAST IRON S32 S32/425 PLUG VALVES, STEEL S32 S32/430 PLUG VALVES, TAPER S32 S32/610 STRIPPING OUT S32 S32/620 INSTALLATION GENERALLY S32 S32/625 GAS SAFE REGISTRATION REQUIREMENTS S32 S32/630 INSTALLING GAS METERS S32 S32/640 INSTALLING DOMESTIC GAS PIPELINES S32 S32/650 INSTALLING GAS PIPELINES S32 S32/660 INSTALLING INDUSTRIAL GAS PIPELINES S32 S32/810 DOMESTIC GAS PIPELINES S32 S32/820 SMALL LOW PRESSURE COMMERCIAL AND INDUSTRIAL GAS INSTALLATIONS S32 S32/830 SMALL NATURAL GAS INSTALLATIONS S32 S32/840 COMMERCIAL AND INDUSTRIAL GAS INSTALLATIONS S32 S32/850 PRESSURE TESTING OF NATURAL GAS SUPPLY SYSTEMS S32 S32/860 DOCUMENTATION S32 S32/870 OPERATING TOOLS S32 S32/880 MAINTENANCE S32 S33 LIQUIFIED PETROLEUM GAS SUPPLY SYSTEMS S S33/110 LPG SUPPLY SYSTEM S33 S33/210 DESIGN S33 S33/310 STORAGE VESSELS S33 S33/340 FILLING CONNECTION S33 S33/350 PRESSURE RELIEF VALVES S33 S33/360 SHUT OFF VALVES AND EMERGENCY VALVES S33 S33/370 PIPELINES S33 S33/375 COMPONENTS FOR LPG INSTALLATIONS S33 S33/380 PUMPS AND ELECTRIC MOTORS S33 S33/390 PRESSURE REGULATORS S33 S33/400 VAPORIZERS S33 S33/410 VAPOUR METERS S33 S33/420 INSULATION OF LPG VAPOUR DISTRIBUTION S33 S33/430 TRACE HEATING OF LPG VAPOUR DISTRIBUTION S33 S33/450 TOOLS AND VALVE KEYS S33 S33/610 STRIPPING OUT S33 S33/620 INSTALLING LPG SYSTEMS S33 S33/625 GAS SAFE REGISTRATION REQUIREMENTS S33 S33/630 INSTALLING LPG VESSELS S33 S33/640 INSTALLING LPG PIPELINES S33 S33/650 INSTALLING LPG PIPELINES TO MULTIPLE USERS S33 S33/660 INSTALLING METERS S33 S33/810 PURGING LPG SYSTEMS S33 S33/820 COMMISSIONING LPG SYSTEMS S33 S33/830 DOCUMENTATION S33 S33/840 MAINTENANCE S33 S34 LABORATORY GAS SUPPLY SYSTEMS S S34/110 LABORATORY ARGON SUPPLY SYSTEM S34 S34/120 LABORATORY HELIUM SUPPLY SYSTEM S34 S34/130 LABORATORY HYDROGEN SUPPLY SYSTEM S34 S34/140 LABORATORY NITROGEN SUPPLY SYSTEM S34 S34/150 LABORATORY OXYGEN SUPPLY SYSTEM S34 S34/210 DESIGN S34 S34/310 COMPRESSED GAS CYLINDERS S34 S34/320 HYDROGEN GENERATORS S34 S34/330 NITROGEN GENERATORS S34 S34/340 LIQUID CYLINDERS S34 S34/350 VACUUM INSULATED EVAPORATOR (VIE) STORAGE VESSELS S34 S34/360 PRESSURE REDUCING STATIONS S34 S34/370 GAS ALARMS S34 S34/380 LABORATORY TAPS S34 S34/400 LINE VALVES S34 S34/610 STRIPPING OUT S34 S34/620 INSTALLING COMPRESSED GAS CYLINDERS S34 S34/630 INSTALLING NITROGEN GENERATORS S34 S34/640 INSTALLING LIQUID CYLINDERS S34 S34/650 INSTALLING VACUUM INSULATED EVAPORATOR STORAGE VESSELS S34 S34/805 TESTING AND COMMISSIONING S34 S34/810 DOCUMENTATION S34 S34/820 MAINTENANCE S34 S35 BIOGAS SUPPLY SYSTEMS S S35/110 BIOGAS SYSTEMS S35 S35/210 DESIGN S35 S35/310 ANAEROBIC DIGESTERS S35 S35/320 SECONDARY GAS METERS S35 S35/330 DOMESTIC LOW PRESSURE GAS SUPPLY PIPELINES S35 S35/340 LOW PRESSURE GAS SUPPLY PIPELINES S35 S35/350 BALL VALVES, MANUALLY OPERATED S35 S35/360 PLUG VALVES, CAST IRON S35 S35/370 PLUG VALVES, STEEL S35 S35/380 PLUG VALVES, TAPER S35 S35/390 GAS SOLENOID VALVES S35 S35/400 MECHANICAL SAFETY VALVES S35 S35/410 NON-RETURN VALVES S35 S35/420 GAS BOOSTERS S35 S35/430 GAS FILTERS S35 S35/435 PRESSURE SWITCHES S35 S35/440 SAFETY AND CONTROL DEVICES S35 S35/609 EXECUTION S35 S35/610 STRIPPING OUT S35 S35/620 INSTALLATION GENERALLY S35 S35/630 INSTALLING SECONDARY GAS METERS S35 S35/640 DOMESTIC LOW PRESSURE GAS PIPELINES S35 S35/650 COMMERCIAL AND INDUSTRIAL GAS PIPELINES S35 S35/810 DOMESTIC GAS PIPELINES S35 S35/820 SMALL LOW PRESSURE COMMERCIAL AND INDUSTRIAL GAS INSTALLATIONS S35 S35/830 COMMERCIAL AND INDUSTRIAL GAS PIPELINES S35 S35/840 COMMERCIAL AND INDUSTRIAL GAS INSTALLATIONS S35 S35/850 COMMERCIAL AND INDUSTRIAL GAS FIRED PLANT S35 S35/860 DOCUMENTATION S35 S35/870 OPERATING TOOLS S35 S35/880 MAINTENANCE S35 S40 PETROL AND DIESEL SUPPLY SYSTEMS S S40/110 PETROL SUPPLY SYSTEM S40 S40/120 DIESEL SUPPLY SYSTEM S40 S40/210 DESIGN S40 S40/310 SERVICE TANKS, CARBON STEEL S40 S40/320 SERVICE TANKS, PLASTICS S40 S40/330 STORAGE TANKS, CARBON STEEL S40 S40/340 STORAGE TANKS, PLASTICS S40 S40/350 OUTFLOW HEATERS S40 S40/360 TANK HEATERS S40 S40/370 TRACE HEATING TO PIPELINES S40 S40/380 ANTI-SYPHON VALVES S40 S40/390 FILTERS S40 S40/400 REMOTE-ACTING FIRE SAFETY VALVES S40 S40/410 CONTENTS GAUGES S40 S40/420 FILL POINTS S40 S40/430 SIGHT GLASSES S40 S40/440 OVERFILL ALARMS AND OVERFILL PREVENTION DEVICES S40 S40/450 METERING PUMPS S40 S40/460 FUEL METERS S40 S40/470 DE-AERATION DEVICES S40 S40/610 STRIPPING OUT S40 S40/615 TANK DECOMMISSIONING AND REMOVAL S40 S40/620 INSTALLATION OF TANKS S40 S40/630 INSTALLATION OF PIPELINES S40 S40/640 INSTALLATION OF METERING PUMPS S40 S40/810 DOCUMENTATION S40 S40/820 COMMISSIONING S40 S40/830 MAINTENANCE S40 S41 FUEL OIL SUPPLY SYSTEMS S S41/110 FUEL OIL SUPPLY SYSTEM S41 S41/210 DESIGN S41 S41/310 OIL SERVICE TANKS, CARBON STEEL S41 S41/320 OIL SERVICE TANKS, PLASTICS S41 S41/330 OIL STORAGE TANKS, CARBON STEEL S41 S41/340 OIL STORAGE TANKS, PLASTICS S41 S41/350 CONTENTS GAUGES S41 S41/360 OVERFILL ALARMS AND OVERFILL PREVENTION DEVICES S41 S41/370 OUTFLOW HEATERS S41 S41/380 TANK HEATERS S41 S41/400 TRACE HEATING TO PIPELINES S41 S41/410 ANTI-SYPHON VALVES S41 S41/420 DE-AERATION DEVICES S41 S41/430 FILTERS S41 S41/440 REMOTE ACTING FIRE SAFETY VALVES S41 S41/450 STRAINERS S41 S41/460 WATER SEPARATORS S41 S41/470 OIL METERS S41 S41/480 FILL POINTS S41 S41/610 STRIPPING OUT S41 S41/615 TANK DECOMMISSIONING AND REMOVAL S41 S41/620 TANK INSTALLATION S41 S41/630 OIL SUPPLY PIPELINES INSTALLATION S41 S41/810 COMMISSIONING S41 S41/820 DOCUMENTATION S41 S41/830 MAINTENANCE S41 S42 LIQUID BIOFUEL SUPPLY SYSTEMS S S42/110 BIOFUEL SUPPLY SYSTEM S42 S42/210 DESIGN S42 S42/310 SERVICE TANKS, CARBON STEEL S42 S42/320 SERVICE TANKS, GLASS REINFORCED PLASTICS S42 S42/330 STORAGE TANKS, CARBON STEEL S42 S42/340 STORAGE TANKS, GLASS REINFORCED PLASTICS S42 S42/350 CONTENTS GAUGES S42 S42/360 FILL POINTS S42 S42/370 SIGHT GLASSES S42 S42/380 OVERFILL ALARMS AND OVERFILL PREVENTION DEVICES S42 S42/400 OUTFLOW HEATERS S42 S42/410 TANK HEATERS S42 S42/420 TRACE HEATING TO PIPELINES S42 S42/430 ANTI-SYPHON VALVES S42 S42/440 FILTERS S42 S42/450 REMOTE-ACTING FIRE SAFETY VALVES S42 S42/460 METERING PUMPS S42 S42/470 OIL METERS S42 S42/480 DE-AERATION DEVICES S42 S42/610 STRIPPING OUT S42 S42/615 TANK DECOMMISSIONING AND REMOVAL S42 S42/620 INSTALLATION OF TANKS S42 S42/630 INSTALLATION OF PIPELINES S42 S42/640 INSTALLATION OF METERING PUMPS S42 S42/810 DOCUMENTATION S42 S42/820 COMMISSIONING S42 S51 STEAM AND CONDENSATE SYSTEMS S S51/110 STEAM AND CONDENSATE SYSTEM S51 S51/210 DESIGN S51 S51/310 AIR VENTS S51 S51/315 VACUUM BREAKERS S51 S51/320 AUSTENITIC STAINLESS STEEL SEPARATORS S51 S51/325 CARBON STEEL SEPARATORS S51 S51/330 CAST IRON SEPARATORS S51 S51/335 SG IRON SEPARATORS S51 S51/340 STAINLESS STEEL SEPARATORS S51 S51/345 ORIFICE PLATE FLOW METERS S51 S51/350 SPRING LOADED VARIABLE AREA FLOW METERS S51 S51/355 VORTEX FLOW METERS S51 S51/360 CONTROL VALVES, ELECTRICALLY ACTUATED S51 S51/365 CONTROL VALVES, PNEUMATICALLY ACTUATED S51 S51/370 CONTROL VALVES, SELF-OPERATING S51 S51/375 CONTROL VALVES, SELF-ACTING S51 S51/380 TEMPERATURE CONTROL SYSTEMS, SELF-ACTING S51 S51/385 PRESSURE REDUCING VALVES, DIRECT ACTING S51 S51/390 PRESSURE REDUCING VALVES, DIRECT ACTING BELLOWS SEALED S51 S51/395 PRESSURE REDUCING VALVES, PILOT OPERATED S51 S51/400 EXCESS PRESSURE VALVES S51 S51/405 TEMPERATURE AND PRESSURE CONTROL VALVES S51 S51/410 PRESSURE SURPLUSSING VALVES S51 S51/415 PRESSURE REDUCING AND SURPLUSSING VALVES S51 S51/420 SAFETY VALVES, FULL LIFT S51 S51/425 SAFETY VALVES, POP S51 S51/430 STEAM TRAPS, BALANCED PRESSURE S51 S51/435 STEAM TRAPS, BALL FLOAT S51 S51/440 STEAM TRAPS, BIMETALLIC S51 S51/445 STEAM TRAPS, INVERTED BUCKET S51 S51/450 STEAM TRAPS, THERMODYNAMIC S51 S51/455 STEAM TRAPS, THERMOSTATIC S51 S51/460 SENSOR CHAMBERS S51 S51/465 SENSORS S51 S51/470 STOP VALVES, BALL S51 S51/475 STOP VALVES, BELLOWS SEALED S51 S51/480 STOP VALVES, GLOBE S51 S51/485 STOP VALVES, PISTON S51 S51/490 CHECK VALVES, DISC S51 S51/495 CHECK VALVES, LIFT S51 S51/500 CHECK VALVES, SPLIT DISC S51 S51/505 CHECK VALVES, WAFER S51 S51/510 STRAINERS, ANGLE S51 S51/515 STRAINERS, Y-TYPE S51 S51/520 SIGHT GLASSES, SINGLE WINDOW S51 S51/525 SIGHT GLASSES, DOUBLE WINDOW S51 S51/530 SIGHT GLASSES, MULTI WINDOW S51 S51/535 SIGHT CHECK S51 S51/540 PRESSURE GAUGES, BOURDON TUBE S51 S51/545 AUTOMATIC CONDENSATE PUMPS S51 S51/550 AUTOMATIC CONDENSATE PUMP PACKAGED UNITS S51 S51/555 ELECTRIC POWERED CONDENSATE RECOVERY UNITS S51 S51/560 PACKAGED CLEAN STEAM GENERATORS S51 S51/610 STRIPPING OUT S51 S51/615 INSTALLING AIR VENTS S51 S51/620 INSTALLING VACUUM BREAKERS S51 S51/625 INSTALLING SEPARATORS S51 S51/630 INSTALLATION OF ORIFICE PLATE FLOW METERS S51 S51/635 INSTALLATION OF SPRING LOADED VARIABLE AREA FLOW METERS S51 S51/640 INSTALLATION OF VORTEX FLOW METERS S51 S51/645 INSTALLATION OF CONTROL VALVES S51 S51/650 INSTALLATION OF PRESSURE REDUCING VALVES S51 S51/655 INSTALLING SAFETY VALVES S51 S51/660 INSTALLING BALANCED PRESSURE STEAM TRAPS S51 S51/665 INSTALLING BALL FLOAT STEAM TRAPS S51 S51/670 INSTALLING BIMETALLIC STEAM TRAPS S51 S51/675 INSTALLING INVERTED BUCKET STEAM TRAPS S51 S51/680 INSTALLING THERMODYNAMIC STEAM TRAPS S51 S51/685 INSTALLING THERMOSTATIC STEAM TRAPS S51 S51/690 INSTALLING SENSOR CHAMBERS S51 S51/695 INSTALLATION OF VALVES GENERALLY S51 S51/700 INSTALLATION OF CHECK VALVES S51 S51/705 INSTALLATION OF STRAINERS S51 S51/710 INSTALLATION OF SIGHT GLASSES S51 S51/715 INSTALLATION OF AUTOMATIC PUMPS S51 S51/720 INSTALLATION OF AUTOMATIC PUMP PACKAGED UNITS S51 S51/725 INSTALLATION OF ELECTRIC POWERED CONDENSATE RECOVERY UNITS S51 S51/810 TESTING S51 S51/820 DOCUMENTATION S51 S51/830 OPERATING TOOLS S51 S51/840 MAINTENANCE S51 S60 FIRE HOSE REEL SYSTEMS S S60/110 FIRE HOSE REEL SYSTEM S60 S60/210 DESIGN S60 S60/310 EMERGENCY TANK FILL CONNECTIONS S60 S60/320 TOWNS MAIN S60 S60/330 STORAGE TANKS S60 S60/340 HOSE REELS S60 S60/350 CONTROL PANELS S60 S60/360 FLOW SWITCHES S60 S60/370 ALARMS S60 S60/610 STRIPPING OUT S60 S60/620 INSTALLING EMERGENCY TANK FILL CONNECTIONS S60 S60/630 INSTALLING PIPELINES S60 S60/640 PIPELINES FIXING S60 S60/650 INSTALLING HOSE REELS S60 S60/660 IDENTIFICATION AND LABELS S60 S60/810 FLUSHING S60 S60/820 TESTING S60 S60/830 SETTING IT TO WORK S60 S60/840 DOCUMENTATION S60 S60/850 OPERATING TOOLS S60 S61 DRY RISER SYSTEMS S S61/110 DRY RISER SYSTEM S61 S61/210 DESIGN S61 S61/310 INLET BREECHINGS AND BOXES S61 S61/320 LANDING VALVES AND BOXES S61 S61/330 COUPLINGS S61 S61/340 CAPS AND CHAINS S61 S61/350 DRAIN VALVES S61 S61/360 AIR RELEASE VALVES S61 S61/370 NON-RETURN VALVES S61 S61/380 LEATHER STRAPS S61 S61/610 STRIPPING OUT S61 S61/620 INSTALLING INLET BREECHINGS S61 S61/630 INSTALLING PIPELINES S61 S61/640 INSTALLING LANDING VALVES S61 S61/650 IDENTIFICATION AND LABELS S61 S61/810 FLUSHING S61 S61/820 TESTING S61 S61/830 SETTING TO WORK S61 S61/840 DOCUMENTATION S61 S61/850 OPERATING TOOLS S61 S62 WET RISER SYSTEMS S S62/110 WET RISER SYSTEM S62 S62/210 DESIGN S62 S62/310 EMERGENCY TANK FILL CONNECTIONS S62 S62/320 STORAGE TANKS S62 S62/330 TOWNS MAIN S62 S62/340 STEEL PIPELINES S62 S62/360 LANDING VALVES S62 S62/370 CONTROL PANELS S62 S62/380 FLOW SWITCHES S62 S62/390 AIR RELEASE VALVES S62 S62/400 ALARMS S62 S62/410 BACKFLOW PREVENTION DEVICES S62 S62/420 CAPS AND CHAINS S62 S62/430 DRAIN VALVES S62 S62/440 LEATHER STRAPS S62 S62/610 STRIPPING OUT S62 S62/620 INSTALLATION FOR USE DURING CONSTRUCTION S62 S62/630 INSTALLING EMERGENCY TANK FILL CONNECTIONS S62 S62/640 INSTALLING PIPELINES S62 S62/650 PIPELINES FIXING S62 S62/660 INSTALLING LANDING VALVES S62 S62/670 IDENTIFICATION AND LABELS S62 S62/810 FLUSHING S62 S62/820 TESTING S62 S62/830 SETTING TO WORK S62 S62/840 DOCUMENTATION S62 S62/850 OPERATING TOOLS S62 S63 SPRINKLER SYSTEMS S S63/110 SPRINKLER SYSTEM S63 S63/210 DESIGN S63 S63/220 EXTENT OF SPRINKLER PROTECTION S63 S63/230 FIRE BRIGADE INLET S63 S63/240 PIPELINE SIZES S63 S63/310 WATER SUPPLY S63 S63/320 SPRINKLER HEADS S63 S63/330 ALARM DEVICES S63 S63/340 ALARM VALVES S63 S63/350 INDICATOR PANELS S63 S63/360 PRESSURE GAUGES S63 S63/610 STRIPPING OUT S63 S63/620 INSTALLING WATER SUPPLY S63 S63/630 INSTALLING ALARM VALVES S63 S63/640 INSTALLING SPRINKLER HEADS S63 S63/650 INSTALLING ALARM DEVICES S63 S63/660 INSTALLING INDICATOR PANELS S63 S63/670 INSTALLING PRESSURE GAUGES S63 S63/680 IDENTIFICATION AND LABELS S63 S63/810 FLUSHING S63 S63/820 TESTING S63 S63/830 SETTING TO WORK S63 S63/840 DOCUMENTATION S63 S63/850 MAINTENANCE S63 S64 DELUGE SYSTEMS S S64/110 DELUGE SYSTEM S64 S64/210 DESIGN S64 S64/220 PIPELINE SIZES S64 S64/310 MULTIPLE CONTROLS S64 S64/320 DELUGE VALVES S64 S64/330 HIGH VELOCITY NOZZLES S64 S64/340 MEDIUM VELOCITY NOZZLES S64 S64/350 ALARM DEVICES S64 S64/360 INDICATOR PANELS S64 S64/370 PRESSURE GAUGES S64 S64/610 STRIPPING OUT S64 S64/620 INSTALLING ALARM DEVICES S64 S64/630 INSTALLING INDICATOR PANELS S64 S64/640 INSTALLING PRESSURE GAUGES S64 S64/650 IDENTIFICATION AND LABELS S64 S64/810 TESTING S64 S64/820 DOCUMENTATION S64 S64/830 SERVICING AND MAINTENANCE S64 S65 FIRE HYDRANT SYSTEMS S S65/110 FIRE HYDRANT SYSTEM S65 S65/210 DESIGN S65 S65/310 DUCTILE IRON PIPELINES S65 S65/320 HIGH DENSITY POLYETHYLENE PIPELINES S65 S65/330 UNPLASTICIZED POLYVINYL CHLORIDE PIPELINES S65 S65/340 UNDERGROUND FIRE HYDRANTS S65 S65/350 INDICATOR PLATES S65 S65/360 SURFACE BOXES S65 S65/370 WARNING MARKER TAPES S65 S65/610 ISOLATION S65 S65/620 STRIPPING OUT S65 S65/630 INSTALLATION GENERALLY S65 S65/640 INSTALLING PIPELINES S65 S65/650 INSTALLING UNDERGROUND FIRE HYDRANTS S65 S65/660 INSTALLING SURFACE BOXES S65 S65/670 INSTALLING INDICATOR PLATES S65 S65/680 INSTALLING WARNING MARKER TAPES S65 S65/810 FLUSHING S65 S65/820 TESTING S65 S65/830 SYSTEM DISINFECTION S65 S65/840 SETTING TO WORK S65 S65/850 DOCUMENTATION S65 S65/860 OPERATING TOOLS S65 S66 WATER MIST SYSTEMS S S66/110 WATER MIST SYSTEM S66 S66/210 DESIGN S66 S66/310 WATER SUPPLY S66 S66/320 NOZZLES S66 S66/330 CONTROL VALVES S66 S66/340 ALARM DEVICES S66 S66/350 INDICATOR PANELS S66 S66/360 PRESSURE GAUGES S66 S66/610 STRIPPING OUT S66 S66/620 INSTALLING ALARM DEVICES S66 S66/630 INSTALLING INDICATOR PANELS S66 S66/640 INSTALLING PRESSURE GAUGES S66 S66/650 IDENTIFICATION AND LABELS S66 S66/810 TESTING LOW PRESSURE SYSTEMS (UP TO 10.4 BAR (1040 KPA)) S66 S66/820 TESTING LOW PRESSURE SYSTEMS (OVER 10.4 BAR (1040 KPA)) S66 S66/830 TESTING INTERMEDIATE AND HIGH PRESSURE SYSTEMS S66 S66/840 DOCUMENTATION S66 S66/850 SPARE NOZZLES S66 S66/860 SERVICING AND MAINTENANCE S66 S70 GASEOUS FIRE-EXTINGUISHING SYSTEMS S S70/110 CARBON DIOXIDE FIRE-EXTINGUISHING SYSTEM S70 S70/120 HALOCARBON GAS TOTAL FLOODING FIRE-EXTINGUISHING SYSTEM S70 S70/130 INERT GAS TOTAL FLOODING FIRE-EXTINGUISHING SYSTEM S70 S70/210 DESIGN S70 S70/220 CARBON DIOXIDE FIRE-EXTINGUISHING SYSTEM S70 S70/230 HALOCARBON GAS FIRE-EXTINGUISHING SYSTEM S70 S70/240 INERT GAS FIRE-EXTINGUISHING SYSTEM S70 S70/310 HIGH PRESSURE STORAGE CYLINDERS S70 S70/320 LOW PRESSURE STORAGE CYLINDERS S70 S70/325 CONTAINER VALVE ASSEMBLIES AND THEIR ACTUATORS S70 S70/326 HIGH AND LOW PRESSURE SELECTOR VALVES AND THEIR ACTUATORS S70 S70/328 CHECK VALVES AND NON-RETURN VALVES S70 S70/330 HOSE REELS S70 S70/340 NOZZLES FOR HALOCARBONS AND INERT GAS FIRE-EXTINGUISHING SYSTEMS S70 S70/341 NOZZLES FOR CARBON DIOXIDE SYSTEMS S70 S70/350 ELECTRICAL ACTUATION S70 S70/360 MECHANICAL ACTUATION S70 S70/370 CONTROL PANELS S70 S70/380 ELECTRICAL AUTOMATIC CONTROL AND DELAY DEVICES S70 S70/390 NON-ELECTRICAL AUTOMATIC CONTROL AND DELAY DEVICES S70 S70/400 MANUAL TRIGGERING AND STOP DEVICES S70 S70/410 NON-ELECTRICAL DISABLE DEVICES S70 S70/420 PNEUMATIC ALARM DEVICES S70 S70/440 FLEXIBLE CONNECTORS S70 S70/450 PRESSURE GAUGES AND PRESSURE SWITCHES S70 S70/460 ODORIZING DEVICES S70 S70/610 STRIPPING OUT S70 S70/620 INSTALLING STORAGE CYLINDERS S70 S70/630 INSTALLING NOZZLES S70 S70/640 INSTALLING CONTROL PANELS S70 S70/810 TESTING S70 S70/820 SETTING TO WORK S70 S70/830 DOCUMENTATION S70 S70/840 OPERATING TOOLS S70 S70/850 MAINTENANCE S70 S76 FOAM FIRE FIGHTING SYSTEMS S S76/110 FOAM FIRE FIGHTING SYSTEM S76 S76/210 DESIGN S76 S76/310 FOAM INLET ADAPTORS S76 S76/320 INSTANTANEOUS MALE COUPLINGS S76 S76/330 FOAM INLET BOXES S76 S76/340 TANKS S76 S76/350 FOAM SPRINKLERS S76 S76/360 FUSIBLE LINKS S76 S76/370 FOAM PROPORTIONERS S76 S76/610 STRIPPING OUT S76 S76/620 INSTALLING FOAM INLET BOXES S76 S76/630 INSTALLING FOAM SPRINKLERS S76 S76/810 TESTING S76 S76/820 SETTING TO WORK S76 S76/830 DOCUMENTATION S76 S76/840 OPERATING TOOLS S76 S90 HOT AND COLD WATER SUPPLY SYSTEMS - DOMESTIC S S90/110 MAINS COLD WATER SUPPLY S90 S90/120 STORAGE COLD WATER SUPPLY S90 S90/130 INSTANTANEOUS HOT WATER SUPPLY S90 S90/140 DIRECT HOT WATER STORAGE SUPPLY S90 S90/150 INDIRECT HOT WATER STORAGE SUPPLY S90 S90/160 RAINWATER/ GREYWATER RECYCLING SYSTEM S90 S90/210 DESIGN S90 S90/220 COLD WATER SUPPLY S90 S90/230 INSTANTANEOUS HOT WATER SUPPLY S90 S90/240 CENTRALIZED HOT WATER STORAGE S90 S90/250 PIPELINE SIZES S90 S90/260 DRAW OFF REQUIREMENTS S90 S90/270 COMBUSTION AIR SUPPLY TO GAS APPLIANCES S90 S90/310 DEZINCIFICATION S90 S90/315 WATER METERS S90 S90/320 CISTERNS FOR NON-POTABLE WATER S90 S90/325 CISTERNS FOR POTABLE WATER S90 S90/330 WATER SOFTENERS S90 S90/345 EVACUATED TUBE SOLAR COLLECTORS S90 S90/347 FLAT PLATE SOLAR COLLECTORS S90 S90/350 INSTANTANEOUS SHOWER UNITS, ELECTRIC S90 S90/360 INSTANTANEOUS WATER HEATERS, ELECTRIC S90 S90/365 INSTANTANEOUS WATER HEATERS, GAS FIRED S90 S90/370 DIRECT HOT WATER STORAGE CYLINDERS S90 S90/380 DIRECT INSULATED COMBINATION UNITS S90 S90/390 IMMERSION HEATERS S90 S90/400 STORAGE WATER HEATERS, ELECTRIC S90 S90/405 STORAGE WATER HEATERS, GAS FIRED S90 S90/410 INDIRECTLY HEATED UNVENTED HOT WATER STORAGE S90 S90/420 INDIRECT HOT WATER STORAGE CYLINDERS, DOUBLE FEED S90 S90/425 INDIRECT HOT WATER STORAGE CYLINDERS, SINGLE FEED S90 S90/430 INDIRECT INSULATED COMBINATION UNITS, DOUBLE FEED S90 S90/435 INDIRECT INSULATED COMBINATION UNITS, SINGLE FEED S90 S90/450 METAL FLUE PIPES S90 S90/460 CANNED ROTOR WATER PUMPS S90 S90/470 CLOSE COUPLED IN LINE PUMPS S90 S90/500 COPPER PIPELINES, CHROMIUM PLATED S90 S90/510 COPPER PIPELINES FOR GENERAL USE S90 S90/515 COPPER PIPELINES FOR UNDERGROUND USE S90 S90/520 POLYETHYLENE PIPELINES FOR UNDERGROUND USE S90 S90/530 STAINLESS STEEL PIPELINES S90 S90/540 THERMOPLASTICS PIPELINES S90 S90/560 WARNING/ OVERFLOW PIPES TO CISTERNS S90 S90/565 TRACE HEATING TAPE FOR PIPELINES S90 S90/570 INSULATION TO PIPELINES S90 S90/580 MASKING PLATES S90 S90/590 PIPEDUCTS S90 S90/600 RAINWATER/ GREYWATER RECYCLING SYSTEM CONTROL UNITS S90 S90/610 TIMERS S90 S90/615 THERMOSTATS S90 S90/620 VALVES GENERALLY S90 S90/625 BALL VALVES S90 S90/630 DOUBLE CHECK VALVE ASSEMBLIES S90 S90/640 DRAINING TAPS S90 S90/650 FLOW REDUCING/ SERVICING VALVES S90 S90/660 GATE VALVES S90 S90/670 STOP VALVES AND DRAW-OFF TAPS, ABOVE GROUND S90 S90/675 STOP VALVES, UNDERGROUND S90 S90/680 THERMOSTATIC MIXING VALVES S90 S90/690 FLUSH CONTROL DEVICES S90 S90/695 WATER COOLERS S90 S90/710 STRIPPING OUT S90 S90/715 INSTALLATION GENERALLY S90 S90/718 INSTALLING WATER METERS S90 S90/720 INSTALLING CISTERNS S90 S90/725 INSTALLING WARNING/ OVERFLOW PIPES TO CISTERNS S90 S90/727 INSTALLING VENT PIPES OVER CISTERNS S90 S90/730 INSTALLING WATER SOFTENERS S90 S90/745 INSTALLING SOLAR PANELS S90 S90/750 INSTALLING GAS FIRED INSTANTANEOUS WATER HEATERS S90 S90/760 UNVENTED HOT WATER STORAGE DISCHARGE PIPES S90 S90/770 INSTALLING FLUE PIPE S90 S90/780 BALANCED FLUE TERMINAL S90 S90/790 PIPELINES INSTALLATION S90 S90/800 PIPELINES FIXING S90 S90/805 INSTALLING THERMOPLASTICS PIPELINE S90 S90/810 SUPPORTS FOR COPPER AND STAINLESS STEEL PIPELINES S90 S90/815 SUPPORTS FOR EXPOSED THERMOPLASTICS PIPELINES S90 S90/820 BENDS IN THERMOPLASTICS PIPELINES S90 S90/830 PIPELINE SPACING S90 S90/840 JOINTS IN COPPER AND STAINLESS STEEL PIPELINES S90 S90/841 CAPILLARY JOINTS IN PLASTICS COATED PIPELINES S90 S90/845 JOINTS IN THERMOPLASTICS PIPELINES S90 S90/850 PIPELINES ENTERING BUILDINGS S90 S90/855 EXTERNAL SUPPLY PIPELINES S90 S90/860 INSTALLATION OF INSULATION TO PIPELINES S90 S90/865 INSTALLING INSULATION TO CISTERNS S90 S90/870 INSTALLING VALVES S90 S90/910 FLUSHING AND FILLING S90 S90/920 SYSTEM DISINFECTION S90 S90/930 TESTING S90 S90/940 COMMISSIONING S90 S90/950 TESTING SERVICE PIPELINES S90 S90/960 DOCUMENTATION S90 S90/970 OPERATING TOOLS S90 S90/980 LABELS S90 S91 NATURAL GAS SUPPLY SYSTEMS – DOMESTIC S S91/110 INCOMING GAS SUPPLY S91 S91/120 GAS SYSTEM S91 S91/210 DESIGN S91 S91/220 PIPELINE SIZES S91 S91/310 SAFETY AND CONTROL DEVICES S91 S91/320 SECONDARY GAS METERS S91 S91/330 DOMESTIC LOW PRESSURE GAS SUPPLY PIPELINES S91 S91/340 GAS PLUG COCKS S91 S91/350 GAS BALL VALVES S91 S91/610 INSTALLATION GENERALLY S91 S91/620 GAS SAFE REGISTRATION REQUIREMENTS S91 S91/910 TESTING, COMMISSIONING AND PURGING GAS PIPELINES S91 S91/920 DOCUMENTATION S91 S91/930 OPERATING TOOLS S91 S92 SPRINKLER SYSTEM - DOMESTIC S S92/110 SPRINKLER SYSTEMS S92 S92/210 DESIGN AND DETAILING S92 S92/220 EXTENT OF SPRINKLER PROTECTION S92 S92/230 PIPELINE SIZES S92 S92/310 WATER SUPPLY S92 S92/320 GRAVITY TANKS S92 S92/330 PRESSURE TANKS S92 S92/340 COPPER PIPELINES S92 S92/350 POLYETHYLENE PIPELINES S92 S92/360 PVC–U PIPELINES S92 S92/370 STEEL PIPELINES S92 S92/380 THERMOPLASTICS PIPES S92 S92/390 PUMPS S92 S92/400 SPRINKLER HEADS S92 S92/410 ALARM PANELS S92 S92/420 ALARM VALVES S92 S92/430 INDICATOR PANELS S92 S92/440 PRESSURE GAUGES S92 S92/610 STRIPPING OUT S92 S92/620 INSTALLING PIPELINES S92 S92/630 FIXING PIPELINES S92 S92/640 INSTALLING PUMPS S92 S92/650 INSTALLING SPRINKLER HEADS S92 S92/660 INSTALLING ALARM VALVES S92 S92/670 INSTALLING ALARM PANELS S92 S92/680 INSTALLING PRESSURE GAUGES S92 S92/690 IDENTIFICATION AND LABELS S92 S92/810 FLUSHING S92 S92/820 TESTING S92 S92/830 SETTING TO WORK S92 S92/840 DOCUMENTATION S92 T MECHANICAL HEATING, COOLING AND REFRIGERATION T10 HEATING SYSTEMS T T10/110 LOW TEMPERATURE HOT WATER HEATING SYSTEM T10 T10/120 MEDIUM TEMPERATURE HOT WATER HEATING SYSTEM T10 T10/130 STEAM HEATING SYSTEM T10 T10/140 SOLAR HEATING SYSTEM T10 T10/150 DIRECT GAS FIRED HEATING SYSTEM T10 T10/160 ELECTRIC HEATING SYSTEM T10 T10/210 DESIGN AND DETAILING T10 T10/220 BASIC DESIGN TEMPERATURES T10 T10/230 THERMAL INSULATION OF BUILDING FABRIC - SPECIFIED U-VALUES T10 T10/240 THERMAL INSULATION OF BUILDING FABRIC – DERIVED VALUES T10 T10/250 SYSTEM OPERATING PARAMETERS T10 T10/260 HEATING SYSTEM CAPACITY T10 T10/270 HEATING AND HOT WATER SUPPLY SYSTEM CAPACITY T10 T10/275 VARIABLE FLOW PIPEWORK SYSTEMS T10 T10/280 ELIMINATION OF GRAVITY CIRCULATION T10 T10/285 COMBUSTION AIR SUPPLY TO GAS FIRED APPLIANCES T10 T10/290 SUBMITTALS T10 T10/610 STRIPPING OUT T10 T10/620 INSTALLING WATER BASED HEATING SYSTEMS T10 T10/630 INSTALLING SOLAR HEATING SYSTEMS T10 T10/640 INSTALLING ELECTRIC HEATING SYSTEMS T10 T10/805 HYDRAULIC PRESSURE TESTING OF LOW TEMPERATURE HOT WATER HEATING SYSTEMS T10 T10/810 DOCUMENTATION T10 T10/820 OPERATING TOOLS T10 T10/830 MAINTENANCE T10 T20 GAS AND OIL FIRED BOILERS T T20/310 GAS FIRED BOILERS T20 T20/320 GAS FIRED CONDENSING BOILERS T20 T20/330 GAS FIRED CAST IRON BOILERS T20 T20/340 OIL FIRED CAST IRON BOILERS T20 T20/350 DUAL FUEL FIRED CAST IRON BOILERS T20 T20/360 GAS FIRED STEEL SHELL BOILERS T20 T20/370 OIL FIRED STEEL SHELL BOILERS T20 T20/380 DUAL FUEL FIRED STEEL SHELL BOILER T20 T20/400 AIR SUPPLY TO APPLIANCES T20 T20/610 INSTALLING BOILERS T20 T23 STEAM BOILERS AND EQUIPMENT T T23/310 GAS FIRED STEAM BOILER T23 T23/320 OIL FIRED STEAM BOILERS T23 T23/330 FEEDTANKS T23 T23/340 BLOWDOWN VESSELS T23 T23/350 BLOWDOWN VALVES T23 T23/360 LEVEL CONTROLS AND ALARMS T23 T23/370 FLASH STEAM RECOVERY T23 T23/380 SAMPLE COOLERS T23 T23/610 INSTALLING BOILERS T23 T24 SOLID FUEL BOILERS T T24/310 CAST IRON BOILERS T24 T24/320 STEEL SHELL BOILERS T24 T24/330 FUEL HANDLING EQUIPMENT T24 T24/340 ASH HANDLING EQUIPMENT T24 T24/610 INSTALLING BOILERS T24 T25 COMBINED HEAT AND POWER SYSTEMS T T25/110 COMBINED HEAT AND POWER SYSTEM T25 T25/210 DESIGN T25 T25/220 HEAT RECOVERY T25 T25/240 OPERATING REQUIREMENTS T25 T25/310 PACKAGED CHP UNITS T25 T25/320 PRIME MOVERS T25 T25/330 GENERATORS T25 T25/340 HEAT EXCHANGERS T25 T25/350 EXHAUST SILENCERS T25 T25/360 GAS COMPRESSORS T25 T25/400 MONITORING AND RECORDING EQUIPMENT T25 T25/410 METERING EQUIPMENT T25 T25/610 STRIPPING OUT COMBINED HEAT AND POWER SYSTEM T25 T25/615 INSTALLING COMBINED HEAT AND POWER T25 T25/620 INSTALLING GAS EQUIPMENT T25 T25/630 CONNECTING TO PUBLIC SUPPLY NETWORK T25 T25/810 COMMISSIONING T25 T25/820 DOCUMENTATION T25 T25/830 SPARES AND CONSUMABLES T25 T25/840 SITE TRAINING T25 T25/850 MAINTENANCE T25 T26 SOLAR COLLECTORS T T26/310 EVACUATED TUBE COLLECTORS T26 T26/320 FLAT PLATE COLLECTORS T26 T26/330 CONTROL UNITS T26 T26/340 EXPANSION VESSELS T26 T26/350 SOLAR TRACKING T26 T26/360 HEAT STORE T26 T26/610 INSTALLATION GENERALLY T26 T30 HEAT EMITTERS T T30/310 AIR CURTAINS T30 T30/320 FAN CONVECTORS T30 T30/330 HEATED TOWEL RAILS, LTHW T30 T30/335 HEATED TOWEL RAILS, ELECTRIC T30 T30/340 NATURAL CONVECTORS T30 T30/350 RADIATORS T30 T30/355 RADIANT PANELS T30 T30/360 ROOM HEATERS T30 T30/370 THERMAL STORAGE HEATERS T30 T30/380 TRENCH HEATING T30 T30/390 UNIT HEATERS T30 T30/610 INSTALLATION GENERALLY T30 T30/620 INSTALLING UNIT HEATERS AND AIR CURTAINS T30 T30/630 INSTALLING ELECTRIC TOWEL RAILS T30 T36 GAS FIRED HEATING UNITS T T36/310 CABINET DIRECT HEATERS T36 T36/320 CABINET INDIRECT HEATERS T36 T36/330 RADIANT LUMINOUS HEATERS T36 T36/340 RADIANT TUBE HEATERS T36 T36/350 UNIT HEATERS T36 T36/360 GAS FIRES T36 T36/370 GAS FIRES, DECORATIVE FUEL EFFECT T36 T36/380 GAS FIRES, INSET LIVE FUEL EFFECT T36 T36/610 AIR SUPPLY T36 T36/620 INSTALLING CABINET HEATERS T36 T36/630 INSTALLING RADIANT LUMINOUS HEATERS T36 T36/640 INSTALLING RADIANT TUBE HEATERS T36 T36/650 INSTALLING UNIT HEATERS T36 T36/660 INSTALLING GAS FIRES T36 T40 HEAT PUMP SYSTEMS T T40/110 AIR SOURCE HEAT PUMP SYSTEMS T40 T40/120 WATER SOURCE HEAT PUMP SYSTEMS T40 T40/130 GROUND SOURCE HEAT PUMP SYSTEMS T40 T40/210 DESIGN T40 T40/220 DESIGN PARAMETERS T40 T40/310 AIR TO AIR HEAT PUMPS T40 T40/320 AIR TO WATER HEAT PUMPS T40 T40/330 GAS ENGINE DRIVEN HEAT PUMPS T40 T40/340 GAS FIRED ABSORPTION HEAT PUMPS T40 T40/350 WATER TO AIR HEAT PUMPS T40 T40/360 WATER TO WATER HEAT PUMPS T40 T40/370 GROUND HEAT EXCHANGERS T40 T40/380 REFRIGERANT PIPEWORK AND FITTINGS T40 T40/610 STRIPPING OUT T40 T40/620 INSTALLATION GENERALLY T40 T40/630 INSTALLATION OF GROUND HEAT EXCHANGERS T40 T40/810 DOCUMENTATION T40 T40/820 MAINTENANCE T40 T41 VARIABLE REFRIGERANT FLOW SYSTEMS T T41/110 VARIABLE REFRIGERANT FLOW SYSTEM T41 T41/210 DESIGN T41 T41/310 ELECTRIC DRIVEN COMPRESSORS T41 T41/320 GAS ENGINE DRIVEN COMPRESSORS T41 T41/330 INDOOR UNITS T41 T41/340 REFRIGERANT PIPEWORK AND FITTINGS T41 T41/610 STRIPPING OUT T41 T41/620 INSTALLATION GENERALLY T41 T41/630 INSTALLING GAS ENGINE DRIVEN COMPRESSORS T41 T41/810 DOCUMENTATION T41 T41/820 MAINTENANCE T41 T42 UNDERFLOOR HEATING AND COOLING T T42/310 LOW TEMPERATURE HOT WATER UNDERFLOOR HEATING T42 T42/320 CHILLED WATER UNDERFLOOR COOLING T42 T42/330 COMBINED UNDERFLOOR HEATING AND COOLING T42 T42/340 ELECTRICAL UNDERFLOOR HEATING T42 T42/610 INSTALLATION T42 T50 CHILLED WATER SYSTEMS T T50/110 CHILLED WATER SYSTEM T50 T50/210 DESIGN AND DETAILING T50 T50/220 BASIC DESIGN TEMPERATURES T50 T50/230 THERMAL INSULATION OF BUILDING FABRIC - SPECIFIED U-VALUES T50 T50/240 THERMAL INSULATION OF BUILDING FABRIC – DERIVED VALUES T50 T50/250 SYSTEM OPERATING PARAMETERS T50 T50/260 COOLING SYSTEM CAPACITY T50 T50/265 VARIABLE FLOW PIPEWORK SYSTEMS T50 T50/270 SUBMITTALS T50 T50/610 STRIPPING OUT T50 T50/905 HYDRAULIC PRESSURE TESTING OF CHILLED WATER SYSTEMS T50 T50/910 DOCUMENTATION T50 T50/920 OPERATING TOOLS T50 T50/930 MAINTENANCE T50 T51 CLIMATIC CEILINGS AND BEAM SYSTEMS T T51/110 CLIMATIC BEAM SYSTEMS T51 T51/120 CLIMATIC CEILING SYSTEMS T51 T51/210 DESIGN T51 T51/220 DESIGN PARAMETERS T51 T51/230 CLIMATIC ACTIVE BEAM DESIGN PARAMETERS T51 T51/240 CLIMATIC PASSIVE BEAM DESIGN PARAMETERS T51 T51/250 CLIMATIC CEILING DESIGN PARAMETERS T51 T51/310 CLIMATIC BEAMS, ACTIVE T51 T51/320 CLIMATIC BEAMS, PASSIVE T51 T51/330 CLIMATIC BEAMS, MULTI-SERVICE T51 T51/340 CLIMATIC CEILING PANELS T51 T51/610 STRIPPING OUT T51 T51/620 SETTING OUT T51 T51/630 INSTALLING CLIMATIC BEAMS T51 T51/640 INSTALLING CLIMATIC CEILING PANELS T51 T51/930 DOCUMENTATION T51 T51/940 OPERATING TOOLS T51 T51/950 MAINTENANCE T51 T60 CENTRAL REFRIGERATION PLANT T T60/320 SAFETY AND ENVIRONMENTAL REQUIREMENTS T60 T60/330 AIR COOLED LIQUID CHILLERS T60 T60/340 WATER COOLED LIQUID CHILLERS T60 T60/350 STEAM FIRED ABSORPTION LIQUID CHILLERS T60 T60/360 HOT WATER FIRED ABSORPTION LIQUID CHILLERS T60 T60/370 DIRECT FIRED ABSORPTION LIQUID CHILLERS T60 T60/390 OPEN CIRCUIT COOLING TOWERS T60 T60/400 CLOSED CIRCUIT COOLING TOWERS T60 T60/410 DRY AIR COOLERS T60 T60/420 CHILLED WATER BUFFER VESSELS T60 T60/430 REFRIGERANT PIPEWORK AND FITTINGS T60 T60/610 INSTALLATION GENERALLY T60 T60/620 INSTALLING CHILLERS T60 T60/630 INSTALLING COOLING TOWERS T60 T60/640 INSTALLING REFRIGERANT PIPEWORK T60 T71 COLD ROOM SYSTEMS T T71/110 CATERING COLD ROOM SYSTEMS T71 T71/120 MORTUARY COLD ROOM SYSTEMS T71 T71/210 CATERING COLD ROOM SYSTEM DESIGN T71 T71/220 MORTUARY COLD ROOM SYSTEM DESIGN T71 T71/310 INDOOR REFRIGERATION UNITS T71 T71/320 AIR COOLED CONDENSING UNITS T71 T71/610 STRIPPING OUT T71 T71/620 INSTALLING COLD ROOMS T71 T71/630 INSTALLING INDOOR REFRIGERATION UNITS T71 T71/810 DOCUMENTATION T71 T71/820 MAINTENANCE T71 T90 HEATING SYSTEMS - DOMESTIC T T90/110 HEATING SYSTEM T90 T90/210 DESIGN T90 T90/220 BASIC DESIGN TEMPERATURES T90 T90/225 THERMAL INSULATION OF BUILDING FABRIC T90 T90/226 THERMAL INSULATION OF BUILDING FABRIC T90 T90/230 SYSTEM OPERATING PARAMETERS T90 T90/240 HEATING SYSTEM CAPACITY T90 T90/241 HEATING AND HOT WATER SUPPLY SYSTEM CAPACITY T90 T90/250 SYSTEM CONTROL T90 T90/280 COMBUSTION AIR SUPPLY TO GAS APPLIANCES T90 T90/305 BOILERS, GAS FIRED T90 T90/310 BOILERS, GAS FIRED COMBINATION T90 T90/312 BOILERS, GAS FIRED CONDENSING T90 T90/315 BOILERS, OIL FIRED T90 T90/320 BOILERS, SOLID FUEL T90 T90/325 GAS FIRES T90 T90/330 GAS FIRES, DECORATIVE FUEL EFFECT T90 T90/335 GAS FIRES, INSET LIVE FUEL EFFECT T90 T90/340 GAS FIRES WITH BACK BOILER T90 T90/345 SOLID FUEL COOKERS WITH BOILER T90 T90/350 SOLID FUEL FIRED ROOMHEATERS T90 T90/355 SOLID FUEL FIRED ROOMHEATERS WITH BACK BOILER T90 T90/360 FLUE LINERS T90 T90/365 INSULATED CHIMNEYS T90 T90/370 METAL FLUE PIPES T90 T90/375 LPG STORAGE TANKS AND SERVICE PIPES T90 T90/380 OIL STORAGE TANKS, PLASTICS T90 T90/385 OIL STORAGE TANKS, STEEL T90 T90/390 FEED AND EXPANSION CISTERNS T90 T90/395 COPPER PIPELINES FOR GENERAL USE T90 T90/400 COPPER PIPELINES, PLASTICS COATED T90 T90/410 THERMOPLASTICS PIPELINES T90 T90/415 VENT PIPELINES T90 T90/420 WARNING AND OVERFLOW PIPES TO FEED AND EXPANSION CISTERNS T90 T90/425 VALVES GENERALLY T90 T90/430 MANUAL RADIATOR VALVES T90 T90/435 MOTORIZED VALVES T90 T90/440 THERMOSTATIC RADIATOR VALVES T90 T90/445 CIRCULATING PUMPS T90 T90/450 INSULATION TO PIPELINES TO CONTROL HEAT LOSS T90 T90/455 FAN CONVECTOR HEATERS T90 T90/460 NATURAL CONVECTOR HEATERS T90 T90/465 RADIATORS T90 T90/470 TOWEL WARMER RADIATORS T90 T90/475 UNDERFLOOR HEATING SYSTEMS T90 T90/480 PROGRAMMERS T90 T90/485 THERMOSTATS T90 T90/490 TIMERS T90 T90/500 AIR TO AIR HEAT PUMPS T90 T90/505 AIR TO WATER HEAT PUMPS T90 T90/510 GAS FIRED ABSORPTION HEAT PUMPS T90 T90/515 WATER TO AIR HEAT PUMPS T90 T90/520 WATER TO WATER HEAT PUMPS T90 T90/525 GROUND HEAT EXCHANGERS T90 T90/610 INSTALLATION GENERALLY T90 T90/620 INSTALLATION OF FEED AND EXPANSION CISTERNS T90 T90/630 PIPELINE INSTALLATION T90 T90/640 PIPELINE FIXING T90 T90/650 JOINTS IN COPPER PIPELINES T90 T90/660 JOINTS IN THERMOPLASTICS PIPELINES T90 T90/670 INSTALLATION OF OIL STORAGE TANKS T90 T90/680 INSTALLATION OF HEAT PUMPS GENERALLY T90 T90/690 INSTALLATION OF GROUND HEAT EXCHANGER COLLECTORS T90 T90/810 TESTING T90 T90/820 SETTING TO WORK AND COMMISSIONING T90 T90/830 TESTING GAS PIPELINES T90 T90/840 DOCUMENTATION T90 T90/850 LABELS T90 U VENTILATION AND AIR CONDITIONING SYSTEMS U10 VENTILATION SYSTEMS U U10/110 NATURAL VENTILATION SYSTEM U10 U10/130 MECHANICAL SUPPLY VENTILATION SYSTEM U10 U10/140 MECHANICAL EXTRACT VENTILATION SYSTEM U10 U10/150 TOILET EXTRACT VENTILATION SYSTEM U10 U10/160 KITCHEN EXTRACT VENTILATION SYSTEM U10 U10/210 DESIGN U10 U10/220 VENTILATION STRATEGY ISSUES U10 U10/230 DESIGN PARAMETERS: U10 U10/240 DUCTWORK DESIGN U10 U10/250 SUBMITTALS U10 U10/310 ROOF RIDGE TERMINALS U10 U10/320 ROOF SLOPE TERMINALS U10 U10/330 ROOF STACK TERMINALS U10 U10/610 STRIPPING OUT U10 U10/620 PASSIVE STACK VENTILATION SYSTEMS U10 U10/630 INSTALLING DUCTWORK ON AIR HANDLING UNITS U10 U10/930 DOCUMENTATION U10 U12 KITCHEN EXTRACT EQUIPMENT U U12/310 PRIMARY GREASE FILTERS U12 U12/320 MESH FILTERS U12 U12/330 ULTRA VIOLET LIGHTS U12 U12/510 KITCHEN CANOPIES U12 U12/520 VENTILATED CEILINGS U12 U12/610 GREASE FILTER INSTALLATION U12 U12/620 KITCHEN CANOPY INSTALLATION U12 U12/630 VENTILATED CEILING INSTALLATION U12 U13 CAR PARK VENTILATION SYSTEMS U U13/110 CAR PARK VENTILATION SYSTEM U13 U13/210 DESIGN U13 U13/220 PERFORMANCE CRITERIA U13 U13/310 JET FANS U13 U13/320 POWERED SMOKE AND HEAT EXHAUST VENTILATORS U13 U13/330 NATURAL SMOKE AND HEAT EXHAUST VENTILATORS U13 U13/610 STRIPPING OUT U13 U13/620 INSTALLING JET FANS U13 U13/630 INSTALLING VENTILATORS U13 U13/920 DOCUMENTATION U13 U13/930 SPARES AND CONSUMABLES U13 U13/940 MAINTENANCE U13 U14 SMOKE AND HEAT CONTROL SYSTEMS U U14/110 SMOKE AND HEAT EXHAUST VENTILATION SYSTEM U14 U14/120 PRESSURE DIFFERENTIAL SYSTEM U14 U14/2 TO BE READ WITH PRELIMINARIES/ GENERAL CONDITIONS U14 U14/210 DESIGN U14 U14/220 DESIGN PARAMETERS FOR SYSTEMS TO MAINTAIN A SMOKE-FREE LAYER U14 U14/230 DESIGN OF SMOKE AND HEAT CONTROL SYSTEM U14 U14/240 DESIGN OF PRESSURE DIFFERENTIAL SYSTEM U14 U14/310 STATIC SMOKE BARRIERS U14 U14/315 STANDARD ACTIVE SMOKE BARRIERS U14 U14/316 HIGH TEMPERATURE ACTIVE SMOKE BARRIERS U14 U14/320 POWERED SMOKE AND HEAT EXHAUST VENTILATORS U14 U14/330 NATURAL SMOKE AND HEAT EXHAUST VENTILATORS U14 U14/340 SMOKE DAMPERS U14 U14/350 SWITCHES U14 U14/360 CONTROLLERS U14 U14/610 STRIPPING OUT SMOKE AND HEAT CONTROL SYSTEMS U14 U14/620 INSTALLING VENTILATORS U14 U14/630 INSTALLING SMOKE BARRIERS U14 U14/810 TESTING U14 U14/820 DOCUMENTATION U14 U14/830 SPARES AND CONSUMABLES U14 U14/840 MAINTENANCE U14 U21 SAFETY CABINET AND FUME CUPBOARD EXTRACT SYSTEMS U U21/110 SAFETY CABINET EXTRACT SYSTEM U21 U21/120 FUME CUPBOARD EXTRACT SYSTEM U21 U21/130 RECIRCULATORY FUME CUPBOARDS SYSTEM U21 U21/210 DESIGN U21 U21/310 GENERAL PURPOSE FUME CUPBOARDS U21 U21/315 VARIABLE AIR VOLUME FUME CUPBOARDS U21 U21/320 LAMINAR FLOW CABINETS U21 U21/330 MICROBIOLOGICAL SAFETY CABINETS U21 U21/340 RECIRCULATORY FILTRATION FUME CUPBOARDS U21 U21/350 SCHOOL FUME CUPBOARDS U21 U21/610 STRIPPING OUT SAFETY CABINET AND FUME CUPBOARD EXTRACT SYSTEMS U21 U21/620 FUMIGATION U21 U21/630 INSTALLING FUME CUPBOARDS U21 U21/640 INSTALLING MICROBIOLOGICAL SAFETY CABINETS U21 U21/650 INSTALLING SCHOOL FUME CUPBOARDS U21 U21/810 TESTING U21 U21/820 COMMISSIONING U21 U21/830 DOCUMENTATION U21 U21/840 SPARES AND CONSUMABLES U21 U21/850 MAINTENANCE U21 U24 INDUSTRIAL FUME EXTRACT SYSTEMS U U24/110 VEHICLE EXHAUST EXTRACT SYSTEM U24 U24/130 LOCAL EXHAUST VENTILATION SYSTEM U24 U24/210 DESIGN U24 U24/220 VEHICLE EXHAUST DETAILS U24 U24/230 WELDING DETAILS U24 U24/240 LOCAL EXHAUST VENTILATION (LEV) U24 U24/310 NOZZLES U24 U24/320 CRUSHPROOF HOSES U24 U24/330 HOSE REELS U24 U24/340 SPRING BALANCER HOSE SUPPORT U24 U24/350 RAIL TRACKS U24 U24/360 SELF-SEALING FLOOR PLATES U24 U24/370 FUME EXTRACT POINTS U24 U24/373 CAPTURING HOOD U24 U24/375 ENCLOSING HOOD U24 U24/377 RECEIVING HOOD U24 U24/380 DUCT MOUNTED MODULAR ELECTROSTATIC AIR FILTERS U24 U24/385 AIR CLEANER - PARTICLES U24 U24/390 AUTO WASH ELECTROSTATIC AIR CLEANERS U24 U24/395 AIR CLEANER - GASES AND VAPOURS U24 U24/400 FAN ASSEMBLIES U24 U24/405 LEV AIR MOVERS U24 U24/410 DISCHARGE STACK U24 U24/420 CONTROLS U24 U24/610 STRIPPING OUT U24 U24/620 INSTALLING CAPTURING HOODS U24 U24/622 INSTALLING ENCLOSURE HOODS U24 U24/625 INSTALLING RECEIVING HOODS U24 U24/630 DISCHARGE STACK U24 U24/810 TESTING U24 U24/820 COMMISSIONING U24 U24/830 DOCUMENTATION U24 U24/840 SPARES AND CONSUMABLES U24 U24/850 MAINTENANCE U24 U30 AIR CONDITIONING SYSTEMS U U30/110 CENTRALIZED ALL-AIR CONDITIONING SYSTEM U30 U30/130 FAN COIL UNIT AIR CONDITIONING SYSTEM U30 U30/140 INDUCTION UNIT AIR CONDITIONING SYSTEM U30 U30/150 EXTRACT SYSTEM U30 U30/210 DESIGN U30 U30/220 AIR CONDITIONING STRATEGY ISSUES U30 U30/230 DESIGN PARAMETERS U30 U30/240 DUCTWORK DESIGN U30 U30/250 SUBMITTALS U30 U30/610 STRIPPING OUT U30 U30/620 INSTALLING DUCTWORK ON AIR HANDLING UNITS U30 U30/830 DOCUMENTATION U30 U30/840 SPARES AND CONSUMABLES U30 U30/850 MAINTENANCE U30 U40 INDUCTION UNITS U U40/310 INDUCTION UNITS U40 U40/610 INDUCTION UNIT DRAIN LINE U40 U41 FAN COIL UNITS U U41/310 FAN COIL UNITS U41 U41/610 FAN COIL UNIT DRAIN LINE U41 U42 VARIABLE AIR VOLUME TERMINAL UNITS U U42/310 VAV TERMINAL UNITS U42 U60 LOCAL AIR CONDITIONING SYSTEMS U U60/110 ROOM AIR CONDITIONING SYSTEM U60 U60/120 LOCAL EXTRACT SYSTEM U60 U60/130 LOCAL UNDERFLOOR AIR CONDITIONING SYSTEM U60 U60/150 EVAPORATIVE COOLING SYSTEMS U60 U60/210 DESIGN U60 U60/220 AIR CONDITIONING STRATEGY ISSUES U60 U60/230 DESIGN PARAMETERS U60 U60/240 DUCTWORK DESIGN U60 U60/250 SUBMITTALS U60 U60/310 ROOM AIR CONDITIONING UNITS U60 U60/320 SPLIT COIL ROOM AIR CONDITIONING UNITS U60 U60/330 SPLIT COIL REMOTE AIR COOLED CONDENSING UNITS. U60 U60/340 LOCAL AIR CONDITIONING UNITS U60 U60/350 TERMINAL FAN UNITS U60 U60/360 REFRIGERANT PIPELINES AND FITTINGS U60 U60/370 EVAPORATIVE COOLING UNITS U60 U60/610 STRIPPING OUT LOCAL AIR CONDITIONING SYSTEMS U60 U60/620 INSTALLING LOCAL AIR CONDITIONING REFRIGERATION U60 U60/810 DOCUMENTATION U60 U60/820 MAINTENANCE U60 U80 AIR DUCTWORK AND ANCILLARIES U U80/305 DAMPERS, FIRE AND SMOKE, METAL DUCTWORK U80 U80/306 DAMPERS, FIRE AND SMOKE, PLASTICS DUCTWORK U80 U80/307 DAMPERS, FIRE AND SMOKE, INTUMESCENT U80 U80/310 DAMPERS, NON-RETURN U80 U80/320 DAMPERS, PRESSURE RELIEF U80 U80/330 DAMPERS, SHUT OFF U80 U80/340 FLEXIBLE DUCTWORK U80 U80/350 GUARDS, BIRD U80 U80/360 GUARDS, INSECT U80 U80/370 PRESSURE CONTROL FLAPS U80 U80/380 ACCESS DOORS U80 U80/510 GLASS FIBRE DUCTWORK AND FITTINGS U80 U80/520 FIRE RATED AND SMOKE EXTRACT DUCTWORK AND FITTINGS U80 U80/525 SMOKE EXTRACT DUCTWORK U80 U80/530 PLASTICS DUCTWORK AND FITTINGS, CIRCULAR U80 U80/535 PLASTICS DUCTWORK AND FITTINGS, RECTANGULAR U80 U80/540 PRE-INSULATED DUCTWORK AND FITTINGS U80 U80/550 SHEET METAL DUCTWORK AND FITTINGS, CIRCULAR U80 U80/555 SHEET METAL DUCTWORK AND FITTINGS, FLAT OVAL U80 U80/560 SHEET METAL DUCTWORK AND FITTINGS, RECTANGULAR U80 U80/610 AIR DUCTWORK GENERALLY U80 U80/620 INSTALLATION OF GLASS FIBRE DUCTWORK U80 U80/630 INSTALLATION OF PLASTICS DUCTWORK U80 U80/640 INSTALLATION OF SHEET METAL DUCTWORK U80 U80/645 INSTALLING DUCTWORK SUPPORTS U80 U80/650 SUPPORT OF AIR TERMINAL UNITS IN CEILING GRIDS U80 U80/660 COMPONENT SUPPORT ON PRE-INSULATED DUCTWORK U80 U80/670 DUCTWORK SUPPORT FOR VAPOUR SEAL CONTINUITY U80 U80/680 DUCTWORK SUPPORT, SPECIAL U80 U80/690 DRAINAGE OF DUCTWORK U80 U80/700 TEST HOLES IN DUCTWORK U80 U80/710 INSTALLING CONTROLS AND SENSING EQUIPMENT IN PLASTICS DUCTWORK U80 U80/720 WEATHERPROOFING DUCTWORK PENETRATIONS U80 U80/725 INSTALLING FIRE AND SMOKE CONTROL DAMPERS U80 U80/730 FIRE RATED DUCTWORK SLEEVES U80 U80/740 INSTALLING CONTROL EQUIPMENT AND INSTRUMENTS IN METAL DUCTWORK U80 U80/750 ACCESS TO DAMPERS FOR RESETTING AND MAINTENANCE U80 U80/760 DUCTWORK CLEANLINESS U80 U80/765 SPECIALIST DUCTWORK CLEANING U80 U80/770 VERIFICATION OF CLEANLINESS OF VENTILATION SYSTEMS U80 U80/775 CLEANING OF KITCHEN EXTRACT SYSTEMS U80 U80/780 AIR LEAKAGE TESTING OF HIGH PRESSURE DUCTWORK U80 U80/785 AIR LEAKAGE TESTING OF MEDIUM PRESSURE DUCTWORK U80 U80/790 AIR LEAKAGE TESTING OF PLANT ITEMS U80 U81 AIR HANDLING UNITS U U81/310 AIR HANDLING UNITS U81 U81/320 AIR CONTROL DAMPERS U81 U81/330 PRIMARY FILTERS U81 U81/340 SECONDARY FILTERS U81 U81/350 HUMIDIFIERS U81 U81/360 PREHEATERS U81 U81/370 COOLING COILS U81 U81/380 REHEATER U81 U81/390 FANS U81 U81/400 VARIABLE DUTY FANS U81 U81/405 ATTENUATOR U81 U81/410 DRAIN LINES U81 U81/510 AIR HANDLING UNIT CASING CONSTRUCTION U81 U81/520 AIR HANDLING UNIT ACCESS U81 U81/610 COMPONENT ASSEMBLY U81 U81/620 ACCESS U81 U81/630 COIL INSTALLATION GENERALLY U81 U81/640 HOT WATER COILS INSTALLATION U81 U81/650 DRAIN LINES INSTALLATION U81 U81/660 SERVICES CONNECTIONS U81 U81/670 ISOLATION OF AIR HANDLING UNITS U81 U81/680 SUPPORT FOR AIR HANDLING UNITS U81 U81/700 PRE-COMMISSIONING OF COILS U81 U81/710 AIR LEAKAGE TESTING U81 U81/720 TESTING U81 U82 FANS U U82/310 AXIAL FLOW FANS U82 U82/320 CENTRIFUGAL FANS U82 U82/325 JET FANS U82 U82/330 MIXED FLOW F ANS U82 U82/340 PROPELLER FANS U82 U82/350 ROOF MOUNTED FANS U82 U82/355 SMOKE EXTRACT FANS. U82 U82/360 TOILET EXTRACT FANS U82 U82/370 CONSTRUCTION AND HANDLING U82 U82/610 INSTALLATION U82 U83 AIR FILTRATION U U83/310 PRIMARY FILTERS U83 U83/320 SECONDARY FILTERS U83 U83/325 EFFICIENT PARTICULATE (EPA) FILTERS U83 U83/330 HIGH EFFICIENCY PARTICLE ARRESTOR (HEPA) FILTERS U83 U83/340 ULTRA LOW PARTICLE ARRESTOR (ULPA) FILTERS U83 U83/350 ACTIVATED CARBON FILTERS U83 U83/360 ELECTROSTATIC PRECIPITATORS U83 U83/370 EDGE SEALS U83 U83/380 PRESSURE GAUGES U83 U83/390 TERMINAL FILTER HOUSINGS U83 U83/400 SAFE CHANGE FILTER CHANGING UNITS U83 U83/610 INSTALLING FILTER FRAMES U83 U83/620 INSTALLING FILTERS U83 U83/630 INSTALLING PRESSURE GAUGES U83 U83/810 SPARES U83 U83/820 CLEANING U83 U84 HEATING AND COOLING COILS U U84/310 LOW TEMPERATURE HOT WATER HEATING COILS U84 U84/320 CHILLED WATER COOLING COILS U84 U84/330 REFRIGERANT COOLING COILS U84 U84/340 ELECTRIC HEATER BATTERIES U84 U84/345 GAS FIRED HEATER BATTERIES U84 U84/350 DRAIN TRAPS U84 U84/610 INSTALLATION U84 U84/620 ELIMINATOR PLATES INSTALLATION U84 U84/630 DRAIN TRAP INSTALLATION U84 U85 HEAT RECOVERY U U85/310 PLATE RECUPERATORS U85 U85/320 RUN-AROUND COILS U85 U85/330 THERMAL WHEELS U85 U85/340 HEAT PIPES U85 U85/350 REGENERATORS U85 U85/610 SUPPORT U85 U85/620 INSTALLING ELIMINATOR PLATES U85 U85/630 INSTALLING DRAIN TRAPS U85 U86 AIR TREATMENT U U86/310 STEAM HUMIDIFIERS U86 U86/320 EVAPORATIVE HUMIDIFIER U86 U86/330 WATER ATOMIZING HUMIDIFIER U86 U86/340 DESICCANT DEHUMIDIFIERS U86 U86/610 INSTALLATION U86 U86/620 CONDENSATE CONNECTIONS U86 U86/630 THERMAL EXPANSION U86 U86/640 INSTALLING DRAIN TRAPS U86 U86/650 FIXINGS U86 U87 SILENCERS AND ACOUSTIC TREATMENT U U87/310 CIRCULAR SILENCERS U87 U87/320 RECTANGULAR SILENCERS U87 U87/330 AIR TRANSFER AND CROSS TALK ATTENUATORS U87 U87/340 ACOUSTIC LININGS U87 U87/350 ACOUSTIC INSULATION U87 U87/360 ACOUSTIC LOUVRES U87 U87/610 ACOUSTIC LININGS U87 U87/620 INSTALLING LOUVRES U87 U88 AIR TERMINAL DEVICES U U88/310 AIR TERMINAL DEVICES, SPECIALIST U88 U88/320 AIR TERMINAL LUMINAIRES U88 U88/325 AIR TRANSFER GRILLES U88 U88/330 DIFFUSERS U88 U88/340 DIFFUSERS, DISPLACEMENT VENTILATION U88 U88/350 DIFFUSERS, FLOOR LINEAR U88 U88/360 DIFFUSERS, LINEAR U88 U88/370 DIFFUSERS, SWIRL U88 U88/380 EXTERNAL LOUVRES U88 U88/390 GRILLES U88 U88/400 LAMINAR FLOW PANELS U88 U88/410 PLENUM BOXES, CEILING OR WALL MOUNTED U88 U88/420 PLENUM BOXES, FLOOR MOUNTED U88 U88/430 VENTILATED CEILINGS U88 U88/610 INSTALLATION U88 U88/620 FIXING CIRCULAR AND RECTANGULAR DIFFUSERS U88 U88/630 FIXING FLOOR MOUNTED LINEAR DIFFUSERS U88 U88/640 FIXING LINEAR AND SLOT DIFFUSERS U88 U88/650 FIXING FLOOR MOUNTED SWIRL DIFFUSERS U88 U88/660 FIXING GRILLES U88 U88/670 OPERATION U88 U88/680 BLANKING PLATES U88 U88/690 INSTALLING LOUVRES U88 U88/910 SPARES U88 U90 GENERAL VENTILATION – DOMESTIC U U90/110 VENTILATION FOR HEATING APPLIANCES U90 U90/120 PASSIVE STACK VENTILATION U90 U90/130 LOCAL EXTRACT FAN VENTILATION U90 U90/140 MECHANICAL SUPPLY VENTILATION U90 U90/150 WHOLE HOUSE MECHANICAL VENTILATION U90 U90/210 DESIGN U90 U90/310 VENTILATORS FOR HEATING APPLIANCES U90 U90/320 EXTERNAL AIR INTAKE GRILLES U90 U90/330 ROOF RIDGE AIR INTAKE TERMINALS U90 U90/335 ROOF SLOPE AIR INTAKE TERMINALS U90 U90/340 THROUGH WALL VENTILATOR DUCTS U90 U90/350 WINDOW TRICKLE VENTILATORS U90 U90/360 AIR TRANSFER GRILLES U90 U90/370 RANGE HOODS U90 U90/380 ROOM EXTRACT GRILLES U90 U90/400 CEILING SWEEP FANS U90 U90/410 MULTIPOINT VENTILATION FAN UNITS U90 U90/413 VENTILATION FAN UNITS U90 U90/417 WHOLE HOUSE VENTILATION FAN UNITS U90 U90/420 FLEXIBLE DUCTWORK AND FITTINGS U90 U90/425 RIGID DUCTWORK AND FITTINGS U90 U90/430 CONDENSATION TRAPS U90 U90/440 DAMPERS, AUTOMATIC U90 U90/443 DAMPERS, FIRE U90 U90/447 DAMPERS, MANUAL U90 U90/450 IN-LINE FILTER UNITS U90 U90/460 NON-RETURN VALVES U90 U90/470 PASSIVE HEAT EXCHANGERS U90 U90/480 SILENCERS U90 U90/490 SITE APPLIED INSULATION TO DUCTWORK U90 U90/500 INLET PLENUM BOXES/ GRILLES U90 U90/505 SUPPLY AIR DIFFUSERS U90 U90/510 EXTERNAL EXHAUST GRILLES U90 U90/520 ROOF RIDGE EXHAUST TERMINALS U90 U90/525 ROOF SLOPE EXHAUST TERMINALS U90 U90/530 FAN CONTROLLER UNITS U90 U90/540 PULL CORD SWITCHES U90 U90/545 PULL CORD SWITCHES WITH OVERRUN DEVICE U90 U90/550 SENSORS, AIR QUALITY U90 U90/560 SENSORS, HUMIDITY U90 U90/570 SENSORS, PROXIMITY U90 U90/580 SENSORS, THERMAL U90 U90/610 PASSIVE STACK VENTILATION SYSTEMS U90 U90/620 INSTALLING VENTILATORS FOR HEAT APPLIANCES U90 U90/630 INSTALLING CEILING SWEEP FANS U90 U90/640 INSTALLING MULTIPOINT AND WHOLE HOUSE FANS U90 U90/650 INSTALLING VENTILATION FANS U90 U90/660 FLEXIBLE DUCTWORK U90 U90/670 RIGID DUCTWORK GENERALLY U90 U90/680 INSTALLING CONDENSATE DRAINS U90 U90/690 SITE APPLIED INSULATION U90 U90/910 COMMISSIONING U90 U90/920 OPERATION AND MAINTENANCE U90 V ELECTRICAL SYSTEMS V10 HIGH VOLTAGE CONNECTION V V10/110 INCOMING ELECTRICITY SUPPLY V10 V10/120 ELECTRICITY DISTRIBUTOR V10 V10/130 ELECTRICITY SUPPLIER V10 V10/210 DESIGN V10 V10/220 SUPPLY CHARACTERISTICS V10 V10/610 STRIPPING OUT V10 V10/620 ISOLATION OF SUPPLY V10 V10/630 MANAGEMENT V10 V10/640 LOCATION V10 V10/650 CONNECTION TO THE INCOMING SUPPLY V10 V11 LOW VOLTAGE CONNECTION V V11/110 INCOMING ELECTRICITY SUPPLY V11 V11/120 ELECTRICITY DISTRIBUTOR V11 V11/130 ELECTRICITY SUPPLIER V11 V11/210 DESIGN V11 V11/220 SUPPLY CHARACTERISTICS V11 V11/230 CONNECTING GENERATORS TO THE PUBLIC SUPPLY NETWORK V11 V11/710 GENERAL EXECUTION V11 V11/720 TEMPORARY ISOLATION OF EXISTING SUPPLY V11 V11/730 STRIPPING OUT AND PERMANENT ISOLATION V11 V11/740 CONNECTION V11 V11/750 LOCATION V11 V11/760 EARTHING ARRANGEMENT V11 V11/810 SITE SUPPLY CHARACTERISTICS V11 V11/820 PHASE SEQUENCE V11 V11/830 DOCUMENTATION V11 V12 GENERATOR SYSTEMS V V12/110 CUSTOMIZED RECIPROCATING INTERNAL COMBUSTION ENGINE DRIVEN ALTERNATING CURRENT GENERATOR SYSTEM V12 V12/115 RECIPROCATING INTERNAL COMBUSTION ENGINE DRIVEN ALTERNATING CURRENT GENERATOR SYSTEM V12 V12/120 SYSTEM CONFIGURATION V12 V12/140 INTERNAL COMBUSTION ENGINE ANCILLARIES V12 V12/210 DESIGN V12 V12/215 LOAD CHARACTERISTICS V12 V12/225 PERFORMANCE OF GENERATOR SYSTEMS V12 V12/240 GENERATING SYSTEMS FOR SAFETY SERVICES V12 V12/250 SERVICE CONDITIONS V12 V12/260 SYSTEM MODE OF OPERATION V12 V12/265 GENERATOR SYSTEMS OPERATING IN PARALLEL V12 V12/270 FUEL AND OIL CONSUMPTION V12 V12/275 DIESEL EXHAUST EMISSIONS V12 V12/280 CONNECTING GENERATORS TO THE PUBLIC SUPPLY NETWORK V12 V12/290 NEUTRAL EARTHING V12 V12/310 GENERATOR SET V12 V12/340 INTERNAL COMBUSTION ENGINES V12 V12/345 INTERNAL COMBUSTION ENGINE ELECTRICAL EQUIPMENT V12 V12/350 GOVERNOR V12 V12/370 ALTERNATORS V12 V12/380 AUTOMATIC VOLTAGE REGULATORS V12 V12/450 CONTROL PANEL V12 V12/460 GENERATOR ENCLOSURES V12 V12/470 DAY TANKS V12 V12/480 DRIP TRAYS V12 V12/485 EMERGENCY STOP BUTTONS V12 V12/490 LOAD BANKS V12 V12/495 GENERATOR SET FACTORY INSPECTIONS AND TESTS V12 V12/498 GENERATOR SET ACCEPTANCE TESTS V12 V12/499 GENERATOR SET STANDARD FUNCTIONAL TESTS V12 V12/510 CUSTOM GENERATOR ENCLOSURES V12 V12/550 CUSTOM EXHAUSTS V12 V12/560 FABRICATION PROPOSALS V12 V12/610 STRIPPING OUT V12 V12/620 INTERRUPTIONS TO EXISTING SUPPLIES V12 V12/630 INSTALLING GENERATOR SYSTEMS V12 V12/640 INSTALLING EXHAUSTS V12 V12/650 INSTALLING CONTROL PANELS V12 V12/655 INSTALLING EMERGENCY STOP BUTTONS V12 V12/670 INSTALLING DRIP TRAYS V12 V12/680 INSTALLING PERMANENT LOAD BANKS V12 V12/910 TESTING AND COMMISSIONING GENERALLY V12 V12/940 TESTING GENERATORS OPERATING IN PARALLEL V12 V12/950 PADLOCKS AND KEYS V12 V12/960 DOCUMENTATION V12 V12/970 SPARES AND CONSUMABLES V12 V12/980 LABELLING V12 V12/990 MAINTENANCE V12 V13 SMALL SCALE WIND GENERATING SYSTEMS V V13/110 SMALL SCALE WIND GENERATING SYSTEM V13 V13/2 TO BE READ WITH PRELIMINARIES/ GENERAL CONDITIONS V13 V13/210 DESIGN V13 V13/310 WIND TURBINE V13 V13/320 TURBINE CONTROL UNIT V13 V13/330 INVERTERS V13 V13/350 BATTERIES V13 V13/360 CENTRAL BATTERY ENCLOSURES V13 V13/370 ENERGY METER V13 V13/380 TURBINE SUPPORT STRUCTURES V13 V13/510 WARNING NOTICE V13 V13/610 STRIPPING OUT V13 V13/620 INSTALLATION GENERALLY V13 V13/630 INSTALLATION OF A.C. SWITCH DISCONNECTORS V13 V13/640 INSTALLATION OF INTERCONNECTING CABLING V13 V13/650 INSTALLATION OF TURBINE CONTROL UNIT V13 V13/655 INSTALLATION OF INVERTERS V13 V13/657 INSTALLATION OF BATTERIES V13 V13/658 INSTALLATION OF ENERGY METERS V13 V13/660 INSTALLATION OF LABELLING V13 V13/670 LABELLING OF TURBINE V13 V13/680 EARTHING OF TURBINE SUPPORT STRUCTURE V13 V13/690 LIGHTNING PROTECTION V13 V13/810 INSPECTION AND TESTING V13 V13/820 DOCUMENTATION V13 V13/830 SPARES AND CONSUMABLES V13 V13/840 MAINTENANCE V13 V14 PHOTOVOLTAIC SYSTEMS V V14/110 GRID CONNECTED PHOTOVOLTAIC SYSTEM V14 V14/115 STAND-ALONE PHOTOVOLTAIC SYSTEM V14 V14/210 DESIGN V14 V14/220 WIND UPLIFT LOADS OF PV ROOFING TILES V14 V14/230 ELECTRICAL ARRANGEMENT V14 V14/240 PHOTOVOLTAIC ARRAYS V14 V14/310 PHOTOVOLTAIC MODULES V14 V14/315 MOUNTING FRAMEWORK V14 V14/320 BY-PASS DIODES V14 V14/330 STRING FUSES V14 V14/340 BLOCKING DIODES V14 V14/350 D.C. JUNCTION BOXES V14 V14/380 D.C. BATTERY CHARGE CONTROLLERS V14 V14/385 ENERGY METERS V14 V14/390 STORAGE BATTERIES V14 V14/400 CENTRAL BATTERY ENCLOSURES V14 V14/410 POWER CONDITIONING UNITS V14 V14/610 STRIPPING OUT V14 V14/620 INSTALLATION GENERALLY V14 V14/630 INSTALLING PV ARRAYS V14 V14/640 FRAMEWORK FOR MOUNTING MULTIBOX ASSEMBLIES V14 V14/650 INSTALLING COMPONENTS V14 V14/670 INSTALLING A.C. ISOLATION SWITCHES V14 V14/675 INSTALLING D.C. ISOLATION SWITCHES V14 V14/680 INSTALLING A.C. SWITCHBOARDS V14 V14/685 INSTALLING D.C. SWITCHBOARDS V14 V14/710 INSTALLING BATTERY CHARGE CONTROLLERS V14 V14/720 INSTALLING BATTERIES V14 V14/730 INSTALLING POWER CONDITIONING UNITS V14 V14/740 INSTALLING ENERGY METERS V14 V14/750 INSTALLATION OF TRANSIENT OVER-VOLTAGE SURGE SUPPRESSION DEVICES V14 V14/760 CONNECTION TO ELECTRICITY DISTRIBUTION NETWORK V14 V14/770 INSTALLING INTERCONNECTING CABLES V14 V14/780 EARTHING AND EQUIPOTENTIAL BONDING V14 V14/790 CONNECTION TO LIGHTNING PROTECTION SYSTEM V14 V14/810 GRID CONNECTION V14 V14/820 LABELLING V14 V14/830 CLEANING AND GENERAL INSPECTION V14 V14/840 TESTING AND COMMISSIONING GENERALLY V14 V14/850 PRE-GRID CONNECTION COMMISSIONING TESTS V14 V14/860 DOCUMENTATION V14 V14/870 SPARES AND CONSUMABLES V14 V14/880 MAINTENANCE V14 V20 HIGH VOLTAGE DISTRIBUTION SYSTEMS V V20/110 HIGH VOLTAGE DISTRIBUTION SYSTEM V20 V20/120 PRE-DESIGN SURVEYS AND DATA COLLECTION OF EXISTING HIGH VOLTAGE DISTRIBUTION SYSTEMS V20 V20/210 DESIGN OF HIGH VOLTAGE DISTRIBUTION SYSTEMS V20 V20/220 GRADING STUDY V20 V20/230 DATA LOGGING OF EXISTING HIGH VOLTAGE DISTRIBUTION SYSTEMS V20 V20/240 THERMAL VIDEO IMAGING SURVEYS OF EXISTING HIGH VOLTAGE DISTRIBUTION SYSTEMS V20 V20/610 STRIPPING OUT V20 V20/620 INSTALLING HIGH VOLTAGE DISTRIBUTION SYSTEMS V20 V20/810 TESTING AND INSPECTION OF SWITCHGEAR GENERALLY V20 V20/820 CALIBRATION CERTIFICATES V20 V20/830 DOCUMENTATION V20 V20/840 SPARES AND CONSUMABLES FOR SWITCHGEAR V20 V20/845 SPARES AND CONSUMABLES FOR DRY TYPE TRANSFORMERS V20 V20/850 MAINTENANCE V20 V21 HIGH VOLTAGE SWITCHGEAR V V21/310 HIGH VOLTAGE SWITCHGEAR GENERALLY V21 V21/320 HIGH VOLTAGE SWITCHBOARDS V21 V21/330 RING MAIN UNITS V21 V21/340 HIGH VOLTAGE EARTHING SWITCHES V21 V21/345 HIGH VOLTAGE FUSES V21 V21/350 HIGH VOLTAGE CIRCUIT BREAKERS V21 V21/360 HIGH VOLTAGE DISCONNECTORS V21 V21/370 HIGH VOLTAGE SWITCHES V21 V21/380 HIGH VOLTAGE SWITCH-DISCONNECTORS V21 V21/390 HIGH VOLTAGE SWITCH-FUSE COMBINATIONS V21 V21/410 HIGH VOLTAGE BUSBARS V21 V21/420 AMMETERS AND VOLTMETERS V21 V21/421 FREQUENCY METERS V21 V21/422 PHASE METERS AND POWER FACTOR METERS V21 V21/423 WATTMETERS V21 V21/430 CURRENT TRANSFORMERS V21 V21/440 DIGITAL MULTIFUNCTION METERING EQUIPMENT V21 V21/450 ELECTRONIC COMBINED CURRENT AND VOLTAGE SENSORS V21 V21/460 INDICATOR LAMPS V21 V21/478 SAFETY MATTING V21 V21/480 HIGH VOLTAGE SWITCHGEAR TRIPPING UNITS V21 V21/490 VOLTAGE TRANSFORMERS V21 V21/495 PADLOCKS AND KEYS V21 V21/496 PADLOCK AND KEY CABINETS V21 V21/510 SWITCHGEAR GENERALLY V21 V21/515 PROPOSALS V21 V21/530 CUSTOM ENCLOSURES V21 V21/590 FACTORY INSPECTIONS AND TESTS V21 V21/610 ALTERATIONS TO EXISTING SWITCHGEAR V21 V21/620 INSTALLATION GENERALLY V21 V21/630 CONNECTIONS V21 V21/640 INSTALLING METERING EQUIPMENT V21 V21/650 CLEANING AND GENERAL INSPECTION V21 V21/660 LABELLING V21 V21/670 PADLOCKS AND KEYS V21 V21/680 INSTALLING PADLOCK AND KEY CABINETS V21 V22 FLUID IMMERSED TRANSFORMERS V V22/310 TRANSFORMER V22 V22/320 PADLOCKS AND KEYS V22 V22/510 FACTORY INSPECTIONS V22 V22/610 INSTALLATION GENERALLY V22 V22/620 INSTALLING CONTROLS, INDICATORS AND ALARMS V22 V22/630 CLEANING AND GENERAL INSPECTION V22 V22/640 TESTING AND COMMISSIONING V22 V22/650 OIL TESTS V22 V23 DRY-TYPE TRANSFORMERS V V23/310 TRANSFORMER V23 V23/320 PADLOCKS AND KEYS V23 V23/510 FACTORY INSPECTIONS V23 V23/610 INSTALLATION GENERALLY V23 V23/620 INSTALLING CONTROLS, INDICATORS AND ALARMS V23 V23/630 CLEANING AND GENERAL INSPECTION V23 V23/640 TESTING AND COMMISSIONING V23 V24 HIGH VOLTAGE CABLING V V24/310 HIGH VOLTAGE CABLES GENERALLY V24 V24/320 PAPER INSULATED CABLES V24 V24/330 THERMOSETTING INSULATION CABLES V24 V24/340 LOW SMOKE THERMOSETTING INSULATION CABLES V24 V24/350 EXTRUDED INSULATION CABLES V24 V24/360 HIGH VOLTAGE CABLE TERMINATIONS V24 V24/370 UNDERGROUND PLASTICS CABLE PROTECTION COVERS V24 V24/380 UNDERGROUND CONCRETE CABLE PROTECTION COVERS V24 V24/390 PLASTICS DUCTS FOR UNDERGROUND CABLES V24 V24/400 UNDERGROUND CABLE MARKER TAPE V24 V24/610 INSTALLING HIGH VOLTAGE CABLES V24 V24/620 EXCAVATIONS V24 V24/630 INSTALLING PAPER INSULATED CABLES V24 V24/635 INSTALLING THERMOSETTING INSULATION CABLES V24 V24/640 INSTALLING LOW SMOKE THERMOSETTING INSULATION CABLES V24 V24/650 CABLES IN TRENCHES V24 V24/670 CABLES IN DUCTS V24 V24/680 PROTECTION TAPE FOR BURIED ELECTRICITY SUPPLY CABLE V24 V24/690 INSTALLING HIGH VOLTAGE CABLE JOINTS V24 V24/700 CABLE TESTING AND INSPECTION V24 V30 LOW VOLTAGE DISTRIBUTION SYSTEMS V V30/110 LOW VOLTAGE DISTRIBUTION SYSTEM V30 V30/210 DESIGN V30 V30/215 SURVEYS AND DATA COLLECTION V30 V30/220 GRADING STUDY V30 V30/410 STRIPPING OUT V30 V30/420 INSTALLING LOW VOLTAGE DISTRIBUTION SYSTEMS V30 V30/430 ELECTRICAL PROPERTY MEASUREMENT V30 V30/440 THERMAL VIDEO IMAGING SURVEYS V30 V30/450 CONNECTION TO THE INCOMING SUPPLY V30 V30/920 DOCUMENTATION V30 V30/925 SURVEYS AND DATA COLLECTION V30 V30/930 MAINTENANCE V30 V31 LOW VOLTAGE SWITCHGEAR V V31/310 LOW VOLTAGE SWITCHGEAR GENERALLY V31 V31/320 DISTRIBUTION BOARDS AND CONSUMER UNITS V31 V31/330 CUBICLE SWITCHBOARDS V31 V31/340 MULTI BOX ASSEMBLIES V31 V31/350 CABLE DISTRIBUTION CABINETS V31 V31/360 PROTECTIVE DEVICES GENERALLY V31 V31/365 CIRCUIT BREAKERS V31 V31/367 'J' - TYPE FEEDER PILLAR FUSES V31 V31/370 RESIDUAL CURRENT CIRCUIT BREAKERS V31 V31/375 SWITCHES, DISCONNECTORS, SWITCH-DISCONNECTORS AND FUSE COMBINATION UNITS V31 V31/380 TRANSFER SWITCHING EQUIPMENT (TSE) V31 V31/385 CONTROL AND PROTECTIVE SWITCHING DEVICES V31 V31/390 RESIDUAL CURRENT CIRCUIT BREAKERS WITH INTEGRAL OVERCURRENT PROTECTION V31 V31/400 MINIATURE CIRCUIT BREAKERS V31 V31/405 LOW VOLTAGE FUSES V31 V31/410 CARTRIDGE FUSES V31 V31/415 FUSE LINKS V31 V31/420 BUSBARS V31 V31/425 ANALOGUE METERING EQUIPMENT V31 V31/430 CURRENT TRANSFORMERS V31 V31/435 DIGITAL METERING EQUIPMENT V31 V31/440 INDICATOR LAMPS V31 V31/445 PADLOCKS AND KEYS V31 V31/450 PADLOCK AND KEY CABINETS V31 V31/455 RADIO TELESWITCHES FOR TARIFF AND LOAD CONTROL V31 V31/460 RESIDUAL CURRENT MONITORING DEVICES V31 V31/465 SAFETY MATTING V31 V31/470 SWITCHGEAR TRIPPING UNITS V31 V31/475 TIMESWITCHES FOR TARIFF AND LOAD CONTROL V31 V31/480 MOUNTING FRAMEWORK COMPONENTS V31 V31/490 ENCLOSURES FOR PROTECTIVE DEVICES AND ACCESSORIES V31 V31/510 CUSTOM ENCLOSURES FOR CUBICLE SWITCHBOARDS V31 V31/515 PROPOSALS V31 V31/540 LAYOUT V31 V31/560 WITHDRAWABLE DEVICES V31 V31/580 FACTORY INSPECTIONS V31 V31/610 ALTERATIONS TO EXISTING SWITCHGEAR V31 V31/620 INSTALLING SWITCHGEAR GENERALLY V31 V31/640 INSTALLING METERING EQUIPMENT V31 V31/650 INSTALLING CURRENT TRANSFORMERS V31 V31/660 FRAMEWORK FOR MOUNTING MULTIBOX ASSEMBLIES V31 V31/670 INSTALLING SAFETY MATTING V31 V31/810 TESTING AND COMMISSIONING GENERALLY V31 V31/820 TESTING AND COMMISSIONING OF SITE-ASSEMBLED SWITCHGEAR V31 V31/830 TESTING AND COMMISSIONING OF SWITCH TRIPPING DEVICES V31 V31/835 SPARES AND CONSUMABLES V31 V31/840 SPARE TOOLS V31 V31/850 SPARE FUSES V31 V31/860 PADLOCKS AND SPARE KEYS V31 V31/870 LABELLING V31 V31/880 CALIBRATION CERTIFICATES V31 V32 LOW VOLTAGE CABLING V V32/310 CABLES GENERALLY V32 V32/315 CABLES, CORDS AND CONDUCTORS IDENTIFICATION V32 V32/320 PVC INSULATED CABLES V32 V32/330 FLEXIBLE CORDS V32 V32/340 INDUSTRIAL FLEXIBLE CORDS V32 V32/350 PVC INSULATED CABLES FOR SWITCHGEAR AND CONTROL GEAR V32 V32/360 SINGLE-CORE HEAT RESISTING INSULATING CABLES V32 V32/370 THERMOSETTING INSULATED CABLES V32 V32/380 THERMOSETTING INSULATED AND PVC SHEATHED CABLES (XLPE/ PVC SINGLES) V32 V32/392 THERMOSETTING INSULATED AND PVC SHEATHED ARMOURED CABLES V32 V32/393 THERMOSETTING INSULATED AND LSZH SHEATHED ARMOURED CABLES V32 V32/395 THERMOSETTING INSULATED METAL SCREENED LSZH SHEATHED MULTICORE CABLES V32 V32/410 MINERAL INSULATED CABLES V32 V32/420 FIRE RESISTANT, INSULATED AND SHEATHED CABLES V32 V32/430 FIRE RESISTANT, INSULATED AND SHEATHED ARMOURED CABLES V32 V32/440 SPLIT CONCENTRIC, INSULATED AND SHEATHED CABLES V32 V32/460 INSULATING TAPE V32 V32/465 UNDERGROUND CABLE MARKER TAPE V32 V32/470 UNDERGROUND PLASTICS CABLE PROTECTION COVERS V32 V32/475 UNDERGROUND CONCRETE CABLE PROTECTION COVERS V32 V32/480 CABLE ACCESSORIES V32 V32/610 CABLE INSTALLATION GENERALLY V32 V32/620 CABLE ROUTES V32 V32/630 CABLES CONCEALED IN WALLS AND PARTITIONS V32 V32/640 CABLES IN VERTICAL TRUNKING AND DUCTS V32 V32/650 CABLES IN ACCESSIBLE ROOF SPACES V32 V32/660 CABLES ON CABLE SUPPORTS V32 V32/670 SURFACE MOUNTED CABLES V32 V32/680 CABLES IN TRENCHES V32 V32/700 INSTALLING CABLE DUCTS V32 V32/710 CABLES IN DUCTS V32 V32/720 CABLES IN CONDUIT AND TRUNKING V32 V32/730 INSTALLING MINERAL INSULATED COPPER SHEATHED CABLES V32 V32/740 INSTALLING ARMOURED CABLES V32 V32/750 INSTALLING FLEXIBLE CORDS V32 V32/760 JOINTING AND TERMINATING ARMOURED CABLES V32 V32/770 JOINTING AND TERMINATING ELASTOMER AND PLASTICS INSULATED CABLE V32 V32/780 TERMINATING MINERAL INSULATED CABLES V32 V32/790 MINERAL INSULATED CABLE JOINTS V32 V33 BUSBAR TRUNKING V V33/310 LIGHTING BUSBAR TRUNKING V33 V33/320 POWER BUSBAR TRUNKING V33 V33/340 TAP-OFF UNITS V33 V33/350 FEED UNITS V33 V33/370 FIRE BARRIER UNITS V33 V33/605 INSTALLING BUSBAR TRUNKING GENERALLY V33 V33/610 INSTALLING LIGHTING BUSBAR TRUNKING V33 V33/620 INSTALLING POWER BUSBAR TRUNKING V33 V33/630 INSTALLING TAP OFF UNITS V33 V33/640 INSTALLING FEED UNITS V33 V33/650 INSTALLING FIRE BARRIER UNITS V33 V33/660 ALTERATIONS TO EXISTING BUSBAR TRUNKING V33 V33/810 CLEANING V33 V33/820 TESTING AND COMMISSIONING GENERALLY V33 V33/830 TESTING AND COMMISSIONING OF SITE-ASSEMBLED BUSBAR TRUNKING V33 V33/840 SPARE TOOLS V33 V33/850 LABELLING V33 V33/860 DOCUMENTATION V33 V34 CONTROLS AND STARTERS V V34/310 A.C. SEMICONDUCTOR MOTOR CONTROLLERS AND STARTERS V34 V34/320 ELECTROMECHANICAL CONTACTORS AND MOTOR STARTERS V34 V34/330 TWO STEP AUTOTRANSFORMER STARTERS V34 V34/340 ELECTROMECHANICAL CONTROL CIRCUIT DEVICES V34 V34/370 VARIABLE SPEED DRIVES, INVERTERS AND A.C. DRIVES V34 V34/380 MOTOR PROTECTION RELAYS V34 V34/390 POWER SUPPLIES FOR CONTROL EQUIPMENT V34 V34/410 RUN AND STANDBY CONTROLS V34 V34/420 ENCLOSURES V34 V34/440 MOTOR CONTROL ENCLOSURES V34 V34/470 INDICATOR LAMPS V34 V34/510 WARNING NOTICE V34 V34/810 TESTING AND COMMISSIONING V34 V34/820 SPARE FUSES V34 V34/830 LABELLING V34 V36 AUTOMATIC POWER FACTOR CORRECTION EQUIPMENT V V36/310 AUTOMATIC POWER FACTOR CORRECTION EQUIPMENT V36 V36/320 SEPARATE ENCLOSURES FOR POWER FACTOR CORRECTION EQUIPMENT V36 V36/610 INSTALLING POWER FACTOR CORRECTION EQUIPMENT V36 V36/620 POWER FACTOR ANALYSIS V36 V36/630 FRAMEWORK FOR MOUNTING POWER FACTOR CORRECTION EQUIPMENT V36 V36/680 FACTORY INSPECTIONS OF POWER FACTOR CORRECTION EQUIPMENT V36 V37 HARMONIC FILTERING EQUIPMENT V V37/310 ACTIVE FILTERS V37 V37/320 PASSIVE FILTERS V37 V37/330 HYBRID FILTERS V37 V37/610 GENERAL INSTALLATION V37 V37/620 SURVEY V37 V37/630 INSTALLING HARMONIC FILTERS V37 V37/640 INSTALLING CLOSE COUPLED ACTIVE FILTERS V37 V37/650 INSTALLING CURRENT TRANSFORMERS (CTS) V37 V37/810 INSPECTION, TESTING AND COMMISSIONING GENERALLY V37 V39 ELECTRICAL INSPECTION AND TESTING V V39/810 ELECTRICAL INSPECTION AND TESTING TYPE V39 V39/815 ELECTRICAL TEST ENGINEER V39 V39/820 GENERAL V39 V39/830 PERIODIC INSPECTIONS V39 V39/840 TEST EQUIPMENT CALIBRATION V39 V39/850 INSPECTION AND TEST RESULTS V39 V39/860 ELECTRICAL INSTALLATION CERTIFICATES V39 V39/870 MINOR ELECTRICAL INSTALLATION WORKS CERTIFICATES V39 V39/880 PERIODIC INSPECTION REPORTS V39 V40 SMALL POWER SYSTEMS V V40/110 HARD WIRED LOW VOLTAGE SMALL POWER SYSTEM V40 V40/120 LOW VOLTAGE SMALL POWER SYSTEM WITH PREFABRICATED WIRING V40 V40/210 DESIGN V40 V40/220 HAND DRIERS V40 V40/230 MULTI-GANG POWER OUTLETS V40 V40/310 HAND DRIERS V40 V40/330 MULTI-GANG POWER OUTLETS V40 V40/335 PREFABRICATED CABLING PRODUCTS GENERALLY V40 V40/340 PREFABRICATED LSZH INSULATED SINGLES IN FLEXIBLE CONDUIT V40 V40/345 PREFABRICATED LSZH INSULATED AND SHEATHED MULTI-CORE V40 V40/350 CONNECTION CABLES V40 V40/355 MASTER DISTRIBUTION BOXES V40 V40/360 SLAVE DISTRIBUTION BOXES V40 V40/365 HOME RUN CABLES V40 V40/370 STARTER LEADS V40 V40/375 'T' CONNECTORS V40 V40/610 SMALL POWER INSTALLATION V40 V40/620 STRIPPING OUT V40 V40/630 INSTALLING CABLING TO SOCKET OUTLETS V40 V40/640 INSTALLING FINAL CONNECTIONS V40 V40/650 PARTIAL INSTALLATION V40 V40/660 INSTALLING HAND DRIERS V40 V40/670 INSTALLING PREFABRICATED WIRING V40 V40/820 DOCUMENTATION V40 V40/830 MAINTENANCE V40 V44 UNINTERRUPTIBLE POWER SUPPLIES V V44/310 UNINTERRUPTIBLE POWER SUPPLY (UPS) EQUIPMENT V44 V44/320 SITE SPECIFIC SERVICE CONDITIONS V44 V44/330 EXISTING INPUT POWER SUPPLY V44 V44/340 MANUFACTURER'S INFORMATION V44 V44/350 BATTERIES V44 V44/360 BATTERY MONITORS V44 V44/365 BATTERY SHELVING RACKS V44 V44/370 CONTROLS, INDICATORS AND ALARMS V44 V44/380 CUSTOM ENCLOSURES V44 V44/390 FACTORY TESTS V44 V44/610 INSTALLATION GENERALLY V44 V44/620 INSTALLING BATTERIES V44 V44/630 INSTALLING EXTERNAL MAINTENANCE BYPASS V44 V44/640 INSTALLING CONTROLS, INDICATORS AND ALARMS V44 V44/810 CLEANING AND GENERAL INSPECTION V44 V44/815 LABELLING V44 V44/820 TESTING AND COMMISSIONING V44 V44/840 DOCUMENTATION V44 V44/850 MAINTENANCE V44 V50 GENERAL LIGHTING SYSTEMS V V50/110 HARD WIRED GENERAL LIGHTING SYSTEM V50 V50/120 GENERAL LIGHTING SYSTEM WITH PREFABRICATED WIRING V50 V50/210 DESIGN V50 V50/220 PERFORMANCE V50 V50/230 MAINTENANCE FACTOR CALCULATIONS V50 V50/240 LUMINAIRE AND LAMP MAINTENANCE PROPERTIES V50 V50/250 LIGHTING CALCULATIONS V50 V50/305 PREFABRICATED WIRING PRODUCTS GENERALLY V50 V50/310 CEILING ROSES V50 V50/315 HOME RUN CABLES V50 V50/320 LIGHTING CIRCUIT DISTRIBUTION BOXES V50 V50/330 LUMINAIRE SUPPORTING COUPLERS V50 V50/335 PREFABRICATED LSZH INSULATED SINGLES IN FLEXIBLE CONDUIT V50 V50/340 PRE-FABRICATED LSZH INSULATED AND SHEATHED MULTI-CORE V50 V50/345 LIGHTING EXTENDER LEADS V50 V50/350 LUMINAIRE CONNECTION CABLES V50 V50/355 MASTER DISTRIBUTION BOXES V50 V50/360 SWITCH CONNECTION LEADS V50 V50/365 STARTER LEADS V50 V50/370 SWITCH MODULES V50 V50/375 T CONNECTORS V50 V50/380 RJ45 CABLES V50 V50/610 INSTALLING GENERAL LIGHTING SYSTEMS V50 V50/620 STRIPPING OUT V50 V50/630 MODIFYING EXISTING LIGHTING SYSTEMS V50 V50/640 LIGHTING CIRCUITS V50 V50/650 MANUAL CONTROLS V50 V50/660 INSTALLING PREFABRICATED WIRING V50 V50/805 TESTING AND INSPECTION OF FIXED ELECTRICAL WIRING V50 V50/810 TESTING AND COMMISSIONING OF GENERAL LIGHTING SYSTEMS V50 V50/820 PHOTOMETRIC SURVEY V50 V50/830 DOCUMENTATION V50 V50/840 MAINTENANCE V50 V51 AUTOMATIC LIGHTING CONTROLS V V51/330 TIME SWITCHES V51 V51/340 PHOTOELECTRIC CONTROL UNITS V51 V51/350 DAYLIGHT SENSORS V51 V51/360 EXTRA-LOW VOLTAGE OCCUPANCY SENSORS V51 V51/370 MAINS VOLTAGE OCCUPANCY SENSORS V51 V51/380 COMBINED DAYLIGHT AND OCCUPANCY SENSORS V51 V51/390 REMOTE INFRARED CONTROLLERS V51 V51/410 CENTRAL CONTROLLERS V51 V51/610 INSTALLATION GENERALLY V51 V51/620 CABLE INSTALLATION GENERALLY V51 V51/630 INSTALLING PHOTOELECTRIC CONTROL UNITS V51 V51/640 INSTALLING DAYLIGHT SENSORS V51 V51/650 INSTALLING OCCUPANCY SENSORS V51 V51/660 INSTALLING CENTRAL CONTROLLERS V51 V51/810 CLEANING AND CABLE INSPECTIONS V51 V51/815 LABELLING V51 V51/820 TESTING AND COMMISSIONING V51 V51/840 SPARES AND CONSUMABLES V51 V55 SELF-CONTAINED EMERGENCY LIGHTING AND SIGNAGE SYSTEMS V V55/110 SELF-CONTAINED EMERGENCY LIGHTING AND SIGNAGE SYSTEM V55 V55/130 OPTICAL FIBRE EMERGENCY LIGHTING SYSTEM V55 V55/210 DESIGN V55 V55/220 OPTICAL FIBRE EMERGENCY LIGHTING SYSTEMS DESIGN V55 V55/230 DEFINED ESCAPE ROUTE LIGHTING DESIGN V55 V55/231 ELECTRICAL LOW MOUNTED WAY-GUIDANCE LIGHTING DESIGN V55 V55/232 PHOTOLUMINESCENT LOW MOUNTED WAY-GUIDANCE LIGHTING DESIGN V55 V55/235 OPEN AREA LIGHTING DESIGN V55 V55/237 HIGH RISK TASK AREA LIGHTING DESIGN V55 V55/240 STANDBY LIGHTING DESIGN V55 V55/270 EMERGENCY LIGHTING CALCULATIONS V55 V55/320 EMERGENCY LUMINAIRES GENERALLY V55 V55/330 GENERAL LUMINAIRES RE-ENGINEERED FOR EMERGENCY USE V55 V55/340 OPTICAL FIBRE EMERGENCY LIGHTING V55 V55/350 ELECTRICAL LOW MOUNTED WAY-GUIDANCE LIGHTING V55 V55/360 PHOTOLUMINESCENT LOW MOUNTED WAY-GUIDANCE LIGHTING V55 V55/367 EXTERTNAL ILLUMINATED EMERGENCY SIGNS V55 V55/370 PHOTOLUMINESCENT EMERGENCY SIGNS V55 V55/395 AUTOMATIC TEST FACILITY V55 V55/410 AUTOMATIC CHANGE-OVER CONTACTORS V55 V55/610 STRIPPING OUT V55 V55/620 SAMPLES V55 V55/630 INSTALLATION GENERALLY V55 V55/640 INSTALLING EMERGENCY SIGNS V55 V55/645 INSTALLING OPTICAL FIBRE EMERGENCY LIGHTING V55 V55/650 INSTALLING ELECTRICAL LOW MOUNTED WAY-GUIDANCE SYSTEMS V55 V55/660 INSTALLING PHOTOLUMINESCENT LOW MOUNTED WAY- GUIDANCE SYSTEMS V55 V55/673 INSTALLING TEST SWITCHES V55 V55/675 INSTALLING AUTOMATIC TEST CONTROLLER V55 V55/678 INSTALLING LUMINAIRE AUTOMATIC TEST MODULES V55 V55/680 INSTALLING AUTOMATIC CHANGE-OVER CONTACTORS V55 V55/810 INSPECTION AND TESTING V55 V55/820 EMERGENCY LIGHTING PHOTOMETRIC SURVEY V55 V55/830 DOCUMENTATION V55 V55/840 CERTIFICATION FOR RE-ENGINEERED LUMINAIRES V55 V55/850 CALIBRATION CERTIFICATES V55 V55/860 SPARES V55 V55/870 MAINTENANCE V55 V56 CENTRAL BATTERY EMERGENCY LIGHTING AND SIGNAGE SYSTEMS V V56/110 CENTRAL BATTERY EMERGENCY LIGHTING AND SIGNAGE SYSTEM V56 V56/210 DESIGN V56 V56/220 OPTICAL FIBRE EMERGENCY LIGHTING DESIGN V56 V56/230 DEFINED ESCAPE ROUTE LIGHTING DESIGN V56 V56/231 ELECTRICAL LOW MOUNTED WAY-GUIDANCE LIGHTING DESIGN V56 V56/232 PHOTOLUMINESCENT LOW MOUNTED WAY-GUIDANCE LIGHTING DESIGN V56 V56/235 OPEN AREA LIGHTING DESIGN V56 V56/237 HIGH RISK TASK AREA LIGHTING DESIGN V56 V56/240 STANDBY LIGHTING DESIGN V56 V56/270 EMERGENCY LIGHTING CALCULATIONS V56 V56/310 PRODUCTS GENERALLY V56 V56/315 CENTRAL BATTERY CHARGER UNITS V56 V56/320 BATTERIES V56 V56/325 CENTRAL BATTERY ENCLOSURES V56 V56/330 EMERGENCY LUMINAIRES GENERALLY V56 V56/360 GENERAL LUMINAIRES RE-ENGINEERED FOR EMERGENCY USE V56 V56/370 OPTICAL FIBRE EMERGENCY LIGHTING V56 V56/380 ELECTRICAL LOW MOUNTED WAY-GUIDANCE LIGHTING V56 V56/390 PHOTOLUMINESCENT LOW MOUNTED WAY-GUIDANCE LIGHTING V56 V56/415 EXTERNALLY ILLUMINATED EMERGENCY SIGNS V56 V56/420 PHOTOLUMINESCENT EMERGENCY SIGNS V56 V56/450 AUTOMATIC TEST FACILITY V56 V56/460 AUTOMATIC CHANGE-OVER CONTACTORS V56 V56/485 INTEGRAL DISTRIBUTION BOARDS V56 V56/510 BATTERY ROOM DOOR SIGNAGE V56 V56/520 MOUNTING FRAMEWORK V56 V56/610 STRIPPING OUT V56 V56/620 SAMPLES V56 V56/630 INSTALLATION GENERALLY V56 V56/635 INSTALLING CENTRAL BATTERY CHARGER UNITS V56 V56/637 INSTALLING BATTERIES V56 V56/640 INSTALLING EMERGENCY SIGNS V56 V56/645 INSTALLING OPTICAL FIBRE EMERGENCY LIGHTING V56 V56/650 INSTALLING ELECTRICAL LOW MOUNTED WAY-GUIDANCE SYSTEMS V56 V56/660 INSTALLING PHOTOLUMINESCENT LOW MOUNTED WAY-GUIDANCE SYSTEMS V56 V56/663 INSTALLING TEST SWITCHES V56 V56/665 INSTALLING AUTOMATIC TEST CONTROLLER V56 V56/668 INSTALLING LUMINAIRE AUTOMATIC TEST MODULES V56 V56/810 INSPECTION AND TESTING V56 V56/820 EMERGENCY LIGHTING PHOTOMETRIC SURVEY V56 V56/830 DOCUMENTATION V56 V56/840 CERTIFICATION FOR RE-ENGINEERED LUMINAIRES V56 V56/850 CALIBRATION CERTIFICATES V56 V56/860 SPARES V56 V56/870 MAINTENANCE V56 V57 STATIC INVERTER EMERGENCY LIGHTING AND SIGNAGE SYSTEMS V V57/110 STATIC INVERTER EMERGENCY LIGHTING AND SIGNAGE SYSTEM V57 V57/130 OPTICAL FIBRE EMERGENCY LIGHTING SYSTEM V57 V57/210 DESIGN V57 V57/220 OPTICAL FIBRE EMERGENCY LIGHTING DESIGN V57 V57/230 DEFINED ESCAPE ROUTE LIGHTING DESIGN V57 V57/231 ELECTRICAL LOW MOUNTED WAY-GUIDANCE LIGHTING DESIGN V57 V57/232 PHOTOLUMINESCENT LOW MOUNTED WAY-GUIDANCE LIGHTING DESIGN V57 V57/235 OPEN AREA LIGHTING DESIGN V57 V57/237 HIGH RISK TASK AREA LIGHTING DESIGN V57 V57/240 STANDBY LIGHTING DESIGN V57 V57/270 EMERGENCY LIGHTING CALCULATIONS V57 V57/310 PRODUCTS GENERALLY V57 V57/315 STATIC INVERTER SUPPLY, CONTROLLER AND BATTERY CHARGER V57 V57/320 BATTERIES V57 V57/325 STATIC INVERTER SYSTEM ENCLOSURES V57 V57/330 EMERGENCY LUMINAIRES GENERALLY V57 V57/335 GENERAL LUMINAIRES RE-ENGINEERED FOR EMERGENCY USE V57 V57/370 OPTICAL FIBRE EMERGENCY LIGHTING V57 V57/380 ELECTRICAL LOW MOUNTED WAY-GUIDANCE LIGHTING V57 V57/390 PHOTOLUMINESCENT LOW MOUNTED WAY-GUIDANCE LIGHTING V57 V57/415 EXTERNALLY ILLUMINATED EMERGENCY SIGNS V57 V57/420 PHOTOLUMINESCENT EMERGENCY SIGNS V57 V57/450 AUTOMATIC TEST FACILITY V57 V57/460 AUTOMATIC CHANGE-OVER CONTACTORS V57 V57/470 CONTROL MODULES V57 V57/475 CONTROL MODULE ENCLOSURES V57 V57/485 INTEGRAL DISTRIBUTION BOARDS V57 V57/490 LOCAL CIRCUIT MONITORING DEVICES V57 V57/510 BATTERY ROOM DOOR SIGNAGE V57 V57/520 MOUNTING FRAMEWORK V57 V57/610 STRIPPING OUT V57 V57/620 SAMPLES V57 V57/630 INSTALLATION GENERALLY V57 V57/635 INSTALLING STATIC INVERTER SUPPLY, CONTROLLER AND BATTERY CHARGER V57 V57/637 INSTALLING BATTERIES V57 V57/640 INSTALLING EMERGENCY SIGNS V57 V57/645 INSTALLING OPTICAL FIBRE EMERGENCY LIGHTING V57 V57/650 INSTALLING ELECTRICAL LOW MOUNTED WAY-GUIDANCE SYSTEMS V57 V57/660 INSTALLING PHOTOLUMINESCENT LOW MOUNTED WAY- GUIDANCE SYSTEMS V57 V57/665 INSTALLING TEST SWITCHES V57 V57/670 INSTALLING AUTOMATIC TEST CONTROLLER V57 V57/677 INSTALLING LUMINAIRE AUTOMATIC TEST MODULES V57 V57/810 INSPECTION AND TESTING V57 V57/820 EMERGENCY LIGHTING PHOTOMETRIC SURVEY V57 V57/830 DOCUMENTATION V57 V57/840 SPARES V57 V57/850 CALIBRATION CERTIFICATES V57 V57/860 MAINTENANCE V57 V59 LUMINAIRES AND LAMPS V V59/310 LAMPS GENERALLY V59 V59/320 TUNGSTEN FILAMENT LAMPS V59 V59/325 TUNGSTEN HALOGEN LAMPS V59 V59/330 TUBULAR FLUORESCENT LAMPS V59 V59/335 TWO AND FOUR PIN COMPACT FLUORESCENT LAMPS V59 V59/339 SELF BALLASTED COMPACT FLUORESCENT LAMPS V59 V59/340 METAL HALIDE LAMPS V59 V59/345 HIGH PRESSURE SODIUM LAMPS V59 V59/350 LOW PRESSURE SODIUM LAMPS V59 V59/355 HIGH PRESSURE MERCURY LAMPS V59 V59/357 INDUCTION LAMPS V59 V59/360 AUXILIARY LAMPS V59 V59/370 CONTROL GEAR GENERALLY V59 V59/385 LAMP HOLDERS FOR TUNGSTEN HALOGEN LAMPS V59 V59/390 BAYONET LAMP HOLDERS V59 V59/391 EDISON SCREW LAMP HOLDERS V59 V59/392 FLUORESCENT LAMP HOLDERS V59 V59/395 ENCLOSURES FOR CONTROLGEAR V59 V59/400 LUMINAIRES GENERALLY V59 V59/405 LUMINAIRES V59 V59/410 RECESSED LUMINAIRES V59 V59/420 AIR HANDLING LUMINAIRES V59 V59/425 EMERGENCY LUMINAIRES V59 V59/430 SEPARATED EXTRA-LOW VOLTAGE LIGHTING V59 V59/435 CLINICAL AREA LUMINAIRES V59 V59/440 SEPARATED EXTRA-LOW VOLTAGE LIGHTING TRANSFORMERS V59 V59/450 LIGHTING TRACK V59 V59/455 FLOODLIGHTS V59 V59/460 LUMINAIRE FIRE HOODS V59 V59/510 CUSTOM-BUILT LUMINAIRES GENERALLY V59 V59/520 CUSTOM-BUILT LUMINAIRE V59 V59/530 PROPOSALS FOR CUSTOM-BUILT LUMINAIRES V59 V59/610 SAMPLES V59 V59/620 INSTALLING LUMINAIRES AND LAMPS GENERALLY V59 V59/630 LUMINAIRE CABLE CONNECTIONS V59 V59/640 LUMINAIRES MOUNTED AS PART OF A SUSPENDED CEILING V59 V59/650 INSTALLING LIGHTING TRACK V59 V59/660 INSTALLING EXTRA LOW VOLTAGE LUMINAIRES V59 V59/670 INSTALLING CONTROLGEAR V59 V59/680 INSTALLING SUSPENDED LAMP HOLDERS V59 V59/690 INSTALLING LUMINAIRE SUPPORTS V59 V59/695 INSTALLING FIRE HOODS V59 V59/810 CLEANING V59 V59/820 TESTING AND COMMISSIONING V59 V59/830 SPARES V59 V60 EXTERNAL LIGHTING SYSTEMS V V60/110 ROADWAY LIGHTING SYSTEMS V60 V60/120 AMENITY LIGHTING SYSTEMS V60 V60/210 ROADWAY LIGHTING DESIGN V60 V60/220 AMENITY LIGHTING DESIGN V60 V60/230 MAINTENANCE FACTOR CALCULATIONS V60 V60/240 LUMINAIRE AND LAMP MAINTENANCE PROPERTIES V60 V60/250 LIGHTING CALCULATIONS V60 V60/310 ALUMINIUM LIGHTING COLUMNS V60 V60/320 STEEL LIGHTING COLUMNS V60 V60/330 ALUMINIUM LIGHTING PEDESTALS V60 V60/340 STEEL LIGHTING PEDESTALS V60 V60/350 ALUMINIUM COLUMN LUMINAIRE BRACKETS V60 V60/360 STEEL COLUMN LUMINAIRE BRACKETS V60 V60/370 ALUMINIUM LUMINAIRE BRACKETS V60 V60/380 STEEL LUMINAIRE BRACKETS V60 V60/400 ENCLOSURES FOR CONTROL GEAR V60 V60/410 ELECTRICAL CUT OUTS V60 V60/420 CONCRETE V60 V60/610 STRIPPING OUT V60 V60/620 INSTALLING ROADWAY AND AMENITY LIGHTING SYSTEMS GENERALLY V60 V60/630 MODIFYING EXISTING EXTERNAL LIGHTING SYSTEMS V60 V60/640 INSTALLING ELECTRICAL CUT OUTS V60 V60/670 CONCRETE BASES V60 V60/680 SETTING COMPONENTS IN CONCRETE BASES V60 V60/690 SETTING COMPONENTS IN EARTH V60 V60/700 HANDLING AND ERECTING LIGHTING COLUMNS V60 V60/710 INSTALLING LIGHTING COLUMNS V60 V60/750 COLUMN AND PEDESTAL LABELLING V60 V60/760 CLEANING V60 V60/810 INSPECTION AND TESTING V60 V60/820 COMMISSIONING V60 V60/830 PHOTOMETRIC SURVEY OF ROAD LIGHTING SYSTEM V60 V60/840 PHOTOMETRIC SURVEY OF AMENITY LIGHTING SYSTEM V60 V60/850 DOCUMENTATION V60 V60/860 SPARES V60 V60/870 MAINTENANCE V60 V67 UNDERWATER LIGHTING SYSTEMS V V67/110 UNDERWATER LIGHTING SYSTEM V67 V67/120 CABLING AND CONTAINMENT V67 V67/210 DESIGN V67 V67/220 PERFORMANCE V67 V67/310 SEPARATED EXTRA LOW VOLTAGE (SELV) TRANSFORMERS V67 V67/320 UNDERWATER LUMINAIRES V67 V67/330 CONNECTION BOXES V67 V67/340 WATER LEVEL CONTROLS V67 V67/610 STRIPPING OUT V67 V67/615 INSTALLATION GENERALLY V67 V67/620 INSTALLING CABLE CONTAINMENT V67 V67/630 INSTALLING CONNECTION BOXES V67 V67/640 INSTALLING SEPARATED EXTRA LOW VOLTAGE (SELV) TRANSFORMERS V67 V67/650 INSTALLING UNDERWATER LUMINAIRES V67 V67/660 INSTALLING WATER LEVEL CONTROLS V67 V67/670 INSTALLING CABLING V67 V67/810 TESTING AND COMMISSIONING V67 V67/820 DOCUMENTATION V67 V67/830 SPARES AND CONSUMABLES V67 V67/840 MAINTENANCE V67 V80 ELECTRICAL IDENTIFICATION V V80/310 IDENTIFICATION AND NOTICES V80 V80/330 ELECTRICAL SHOCK TREATMENT SIGNS V80 V80/510 EQUIPMENT LABELS V80 V80/520 DIAGRAMS V80 V80/610 ELECTRICAL IDENTIFICATION V80 V80/620 SAMPLES V80 V80/630 ARRANGEMENT V80 V80/640 IDENTIFYING METAL CONTAINMENT V80 V80/650 IDENTIFYING SUB-MAIN CABLES V80 V80/660 FUNCTIONAL EARTHS V80 V80/670 PROTECTIVE CONDUCTORS V80 V80/680 EQUIPMENT LABELLING AND VOLTAGE WARNING NOTICES V80 V80/690 CIRCUIT CHARTS V80 V80/700 ENGRAVING OF ELECTRICAL ACCESSORIES V80 V80/710 INSTALLING DIAGRAMS V80 V80/720 INSTALLING PERIODIC INSPECTION NOTICES V80 V80/730 INSTALLING MAINTENANCE NOTICES V80 V80/740 INSTALLING ELECTRIC SHOCK TREATMENT SIGNS V80 V80/750 INSTALLING HAZARD SIGNS V80 V81 EARTHING AND BONDING SYSTEMS V V81/110 EARTHING AND BONDING SYSTEMS V81 V81/210 DESIGN V81 V81/220 ELECTRICITY DISTRIBUTOR’S REQUIREMENTS V81 V81/230 EQUIPOTENTIAL BONDING IN BUILDINGS WITH INFORMATION TECHNOLOGY EQUIPMENT V81 V81/240 FUNCTIONAL EARTHING DESIGN V81 V81/250 GENERATOR EARTHING DESIGN V81 V81/255 MOBILE GENERATOR EARTHING V81 V81/260 HIGH INTEGRITY EARTHING DESIGN V81 V81/270 DESIGN FOR HAZARDOUS AREAS V81 V81/280 DESIGN FOR THE SAFE USE AND HANDLING OF FLAMMABLE LIQUIDS V81 V81/290 DESIGN TO MINIMIZE UNDESIRABLE STATIC ELECTRICITY V81 V81/310 PRODUCTS GENERALLY V81 V81/320 EARTHING AND BONDING CONDUCTORS V81 V81/330 FUNCTIONAL EARTH CABLES V81 V81/360 EARTH RODS V81 V81/370 COPPER EARTH PLATES V81 V81/380 EARTH ELECTRODE INSPECTION PITS V81 V81/390 EARTH BARS V81 V81/440 EARTHING AND BONDING CLAMPS V81 V81/450 EARTH PROVING/ MONITORING SYSTEMS V81 V81/460 SOIL CONDITIONING AGENTS V81 V81/470 ANTI VANDAL CAPPING V81 V81/610 GENERAL INSTALLATION V81 V81/620 STRIPPING OUT V81 V81/630 EXISTING INSTALLATIONS V81 V81/640 INSTALLING EARTH CONDUCTOR TAPES V81 V81/650 INSTALLING EARTH CONDUCTOR JOINTS AND CONNECTIONS V81 V81/660 INSTALLING EARTH RODS V81 V81/670 INSTALLING SURFACE BARRIERS AROUND EARTH RODS V81 V81/680 INSTALLING EARTH PLATES V81 V81/685 INSTALLING EARTH PROVING/ MONITORING SYSTEMS V81 V81/690 INSTALLING SOIL CONDITIONING AGENTS V81 V81/700 INSTALLING EARTH BARS V81 V81/710 INSTALLING EARTHING CONDUCTOR V81 V81/720 INSTALLING MAIN PROTECTIVE BONDING CONDUCTORS V81 V81/730 INSTALLING SUPPLEMENTARY BONDING CONDUCTORS V81 V81/740 INSTALLING EARTH ELECTRODE PITS V81 V81/750 DISSIMILAR METALS V81 V81/760 EARTHING AND BONDING OF STREET FURNITURE V81 V81/770 EARTHING OF METAL FENCING AROUND SUBSTATIONS V81 V81/780 NOTICES AND LABELS V81 V81/790 IDENTIFICATION OF FUNCTIONAL EARTHING V81 V81/810 INSPECTION AND TESTING V81 V81/820 DOCUMENTATION V81 V90 ELECTRICAL SYSTEMS - DOMESTIC V V90/110 LOW VOLTAGE SUPPLY V90 V90/130 LV SWITCHGEAR V90 V90/131 LV CABLING V90 V90/132 CONTAINMENT V90 V90/150 EMERGENCY LIGHTING SYSTEMS V90 V90/210 GENERAL DESIGN V90 V90/220 DESIGN OF LOW VOLTAGE INCOMING SUPPLY V90 V90/222 DESIGN OF PHOTOVOLTAIC SYSTEM V90 V90/225 DESIGN OF SMALL SCALE WIND GENERATING SYSTEM V90 V90/230 LV DISTRIBUTION SYSTEM DESIGN V90 V90/235 ARRANGEMENTS OF PARTICULAR CIRCUITS V90 V90/240 GENERAL LIGHTING SYSTEM DESIGN V90 V90/250 EMERGENCY LIGHTING SYSTEM DESIGN V90 V90/260 EXTERNAL LIGHTING SYSTEM DESIGN V90 V90/265 DESIGN AND LIGHTING CALCULATIONS V90 V90/270 CONTROL OF EXTERNAL LUMINAIRES V90 V90/275 SMALL POWER SYSTEM DESIGN V90 V90/280 EARTHING AND BONDING DESIGN V90 V90/310 PRODUCTS GENERALLY V90 V90/312 PHOTOVOLTAIC SYSTEM V90 V90/315 SMALL SCALE WIND GENERATING SYSTEM V90 V90/320 DISTRIBUTION BOARDS AND CONSUMER UNITS V90 V90/330 CABLE TRAYS V90 V90/335 CABLE BASKETS V90 V90/340 CONDUIT V90 V90/341 CABLE TRUNKING AND DUCTING V90 V90/342 STEEL CONDUIT AND FITTINGS V90 V90/343 PVC CONDUIT AND FITTINGS V90 V90/350 STEEL TRUNKING SYSTEMS FOR WALLS AND CEILINGS V90 V90/353 STEEL DUCTING SYSTEMS - FLOOR EMBEDDED V90 V90/355 PVC SURFACE TRUNKING SYSTEMS V90 V90/360 PROPRIETARY TRUNKING/ CABLE MANAGEMENTS SYSTEMS V90 V90/365 FLOOR TRUNKING SYSTEMS V90 V90/370 INTUMESCENT LINEAR GAP SEALS V90 V90/410 CABLES V90 V90/420 PROTECTIVE CONDUCTORS V90 V90/430 ELECTRICAL ACCESSORIES V90 V90/510 LUMINAIRES V90 V90/511 LAMPS GENERALLY V90 V90/515 LUMINAIRE SUPPORTING COUPLERS V90 V90/520 SEPARATED EXTRA LOW VOLTAGE LIGHTING V90 V90/525 DIMMER SWITCHES AND CONTROLS V90 V90/530 SELF CONTAINED EMERGENCY LUMINAIRES V90 V90/540 CENTRAL BATTERY EMERGENCY LIGHTING SYSTEMS V90 V90/550 CENTRAL BATTERY EMERGENCY LUMINAIRES V90 V90/560 EXTERNAL LUMINAIRES V90 V90/565 LIGHTING COLUMNS V90 V90/580 EARTHING AND BONDING EQUIPMENT V90 V90/585 EARTH BARS V90 V90/590 EQUIPMENT V90 V90/592 TIME SWITCHES V90 V90/594 PHOTOELECTRIC CONTROL UNITS V90 V90/596 MOVEMENT DETECTORS V90 V90/610 ELECTRICAL INSTALLATION GENERALLY V90 V90/615 INSTALLING CONNECTION TO INCOMING SUPPLY V90 V90/620 INSTALLING PHOTOVOLTAIC SYSTEMS V90 V90/625 INSTALLING SMALL SCALE WIND GENERATING SYSTEMS V90 V90/630 INSTALLING SWITCHGEAR V90 V90/635 INSTALLING CABLES DIRECTLY IN THE GROUND V90 V90/640 INSTALLING CABLES ENTERING BUILDINGS FROM BELOW GROUND V90 V90/645 INSTALLING CABLE TRAY V90 V90/650 INSTALLING CABLE BASKET V90 V90/655 INSTALLING STEEL CONDUIT AND FITTINGS V90 V90/660 INSTALLING PVC CONDUIT AND FITTINGS V90 V90/665 INSTALLING CONDUIT IN CONCRETE V90 V90/670 INSTALLING TRUNKING/ DUCTING/ SYSTEMS V90 V90/675 PARTIAL INSTALLATION V90 V90/680 CABLE ROUTES V90 V90/685 INSTALLING CABLES V90 V90/690 INSTALLING CABLES IN PLASTER V90 V90/695 INSTALLING CABLES IN VERTICAL TRUNKING/ DUCTS V90 V90/700 INSTALLING CABLES IN ACCESSIBLE ROOF SPACES V90 V90/705 INSTALLING ARMOURED CABLE V90 V90/710 INSTALLING PVC SHEATHED CABLE V90 V90/715 INSTALLING MICC CABLE V90 V90/720 INSTALLING ELECTRICAL ACCESSORIES/ EQUIPMENT V90 V90/725 FINAL CONNECTIONS V90 V90/730 INSTALLING MULTIGANG SWITCHES V90 V90/735 INSTALLING LUMINAIRES V90 V90/740 INSTALLING EMERGENCY LUMINAIRES V90 V90/745 INSTALLING EXTERNAL LUMINAIRES V90 V90/750 INSTALLING LIGHTING COLUMNS V90 V90/755 INSTALLING EARTH BARS V90 V90/760 LABELLING V90 V90/765 ENGRAVING V90 V90/810 FINAL FIX V90 V90/820 CLEANING V90 V90/830 INSPECTION AND TESTING GENERALLY V90 V90/840 TESTING AND COMMISSIONING OF PV SYSTEMS V90 V90/850 TESTING AND COMMISSIONING OF SMALL SCALE WIND GENERATING SYSTEMS V90 V90/860 INSPECTION AND TESTING OF EMERGENCY LIGHTING SYSTEMS V90 V90/870 INSPECTION AND TESTING OF EXTERNAL LIGHTING SYSTEMS V90 V90/880 DOCUMENTATION V90 V90/890 MAINTENANCE V90 V91 ELECTRICAL SYSTEMS - LANDSCAPE V V91/110 LOW VOLTAGE SUPPLY V91 V91/115 EXTERNAL LIGHTING SYSTEM V91 V91/120 SMALL POWER SYSTEM V91 V91/205 DESIGN V91 V91/210 DESIGN OF LOW VOLTAGE SUPPLY V91 V91/220 DESIGN OF LOW VOLTAGE DISTRIBUTION AND SMALL POWER SYSTEMS V91 V91/230 DESIGN OF EXTERNAL LIGHTING SYSTEM V91 V91/245 DESIGN AND LIGHTING CALCULATIONS V91 V91/250 CONDUIT AND TRUNKING V91 V91/260 CABLES GENERALLY V91 V91/303 PRODUCT STANDARDS AND APPROVALS GENERALLY V91 V91/305 PARTICULAR PRODUCT STANDARDS V91 V91/315 CABLE DISTRIBUTION CABINETS V91 V91/320 DISTRIBUTION BOARDS AND CONSUMER UNITS V91 V91/330 RIGID CONDUIT AND FITTINGS V91 V91/332 TRUNKING AND DUCTING V91 V91/335 LUMINAIRES GENERALLY V91 V91/340 LUMINAIRES FOR ROAD AND STREET LIGHTING V91 V91/345 FLOODLIGHTS V91 V91/350 PORTABLE LUMINAIRES FOR GARDEN USE V91 V91/355 UNDERWATER LUMINAIRES V91 V91/360 SEPARATED EXTRA LOW VOLTAGE (SELV) TRANSFORMERS V91 V91/365 LIGHTING COLUMNS GENERALLY V91 V91/370 ALUMINIUM LIGHTING COLUMNS V91 V91/375 STEEL LIGHTING COLUMNS V91 V91/385 LAMPS GENERALLY V91 V91/390 LAMP CONTROLGEAR V91 V91/397 MOVEMENT DETECTORS V91 V91/400 PHOTOELECTRIC CONTROL UNITS V91 V91/405 TIME SWITCHES V91 V91/410 CABLE GUARDS V91 V91/415 CONCRETE CABLE MARKERS V91 V91/420 ENCLOSURES FOR CONTROLGEAR V91 V91/425 UNDERGROUND CABLE MARKER TAPE V91 V91/430 UNDERGROUND PLASTICS CABLE PROTECTION COVERS V91 V91/435 UNDERGROUND CONCRETE CABLE PROTECTION COVERS V91 V91/605 ELECTRICAL INSTALLATION GENERALLY V91 V91/610 ARRANGEMENT OF PARTICULAR CIRCUITS V91 V91/615 INSTALLING STEEL CONDUIT AND FITTINGS V91 V91/616 INSTALLING PVC-U CONDUIT AND FITTINGS V91 V91/620 CABLES ENTERING BUILDINGS FROM BELOW GROUND V91 V91/630 INSTALLING CABLES V91 V91/635 CABLES IN TRENCHES V91 V91/637 INSTALLING UNDERGROUND CABLE PROTECTION COVERS V91 V91/640 INSTALLING UNDERGROUND CABLE MARKER TAPE V91 V91/645 INSTALLING CONCRETE CABLE MARKERS V91 V91/647 INSTALLING CABLE GUARDS V91 V91/648 CONCRETE MIX V91 V91/650 SETTING COMPONENTS IN CONCRETE FOUNDATIONS AND BASES V91 V91/655 SETTING COMPONENTS IN EARTH V91 V91/660 HANDLING AND ERECTING LIGHTING COLUMNS V91 V91/665 SITE PAINTING V91 V91/670 LIGHTING COLUMN IDENTIFICATION V91 V91/675 INSTALLING LUMINAIRES AND LAMPS GENERALLY V91 V91/680 INSTALLING CONTROLGEAR V91 V91/910 INSPECTION AND TESTING V91 V91/915 CLEANING V91 V91/920 COMMISSIONING V91 V91/925 PHOTOMETRIC SURVEY V91 V91/930 DOCUMENTATION V91 V91/935 SPARE LAMPS V91 V91/940 PADLOCKS AND KEYS V91 V91/950 MAINTENANCE V91 W COMMUNICATIONS, SECURITY, SAFETY AND PROTECTION SYSTEMS W11 PUBLIC ADDRESS SYSTEMS W W11/110 PUBLIC ADDRESS SYSTEM W11 W11/210 DESIGN W11 W11/220 SYSTEM PARAMETERS W11 W11/230 DESIGN CRITERIA W11 W11/240 CONNECTION TO FIRE DETECTION AND ALARM SYSTEMS W11 W11/310 AERIALS W11 W11/320 AUTOMATIC ANNOUNCEMENT EQUIPMENT W11 W11/330 CASSETTE PLAYERS W11 W11/335 COMPACT DISC PLAYERS W11 W11/340 EXTERNAL SOURCE INPUT POINTS W11 W11/350 MICROPHONES W11 W11/355 REMOTE MICROPHONE INPUT POINTS W11 W11/360 PAGING CONSOLES W11 W11/370 TUNERS W11 W11/380 AMBIENT NOISE LEVEL SENSING EQUIPMENT W11 W11/400 EQUIPMENT RACKS W11 W11/410 MICROPHONE CABLES W11 W11/415 AERIAL CABLES W11 W11/420 MIXERS W11 W11/425 POWER AMPLIFIERS W11 W11/430 PRE-AMPLIFIERS W11 W11/435 MIXER AMPLIFIERS W11 W11/440 LOUDSPEAKERS W11 W11/450 ARTIFICIAL REVERBERATION, TIME DELAY AND FREQUENCY SHIFT EQUIPMENT W11 W11/460 AUTOMATIC GAIN CONTROL DEVICES W11 W11/470 AUXILIARY PASSIVE ELEMENTS W11 W11/480 EQUALIZERS W11 W11/490 LOCAL VOLUME CONTROLS W11 W11/610 STRIPPING OUT W11 W11/620 INSTALLATION GENERALLY W11 W11/630 MODIFYING EXISTING PUBLIC ADDRESS SYSTEMS W11 W11/635 INSTALLING AERIALS W11 W11/640 INSTALLING EQUIPMENT RACKS AND 'HEAD END' EQUIPMENT W11 W11/645 INSTALLING REMOTE MICROPHONE INPUT POINTS W11 W11/647 INSTALLING EXTERNAL SOURCE INPUT POINTS W11 W11/650 INSTALLING MICROPHONE CABLES W11 W11/660 INSTALLING LOUDSPEAKERS W11 W11/670 INSTALLING LOCAL VOLUME CONTROLS W11 W11/680 SAMPLES W11 W11/690 INSTALLING CABLES GENERALLY W11 W11/810 TESTING AND COMMISSIONING GENERALLY W11 W11/820 SYSTEM RE-COMMISSIONING W11 W11/830 ACOUSTIC TESTING W11 W11/840 EQUIPMENT LABELLING AND SYSTEM DIAGRAMS W11 W11/850 CONSUMABLES W11 W11/860 DOCUMENTATION W11 W11/870 MAINTENANCE W11 W16 INDUCTION-LOOP SYSTEMS W W16/110 AUDIO-FREQUENCY-INDUCTION-LOOP SYSTEM W16 W16/210 DESIGN W16 W16/220 SYSTEM PARAMETERS W16 W16/230 MULTIPLE LOOPS W16 W16/310 PRODUCTS GENERALLY W16 W16/320 MICROPHONES W16 W16/340 FINAL AMPLIFIERS W16 W16/350 TRANSFORMERS W16 W16/360 EQUALIZATION EQUIPMENT W16 W16/380 LOOP PADS W16 W16/420 ILLUMINATED REASSURANCE INDICATORS W16 W16/430 INDUCTION-LOOP MONITOR RECEIVERS W16 W16/440 LOOP FIELD STRENGTH METERS W16 W16/450 SIGNAGE W16 W16/460 TONE SIGNALS W16 W16/610 STRIPPING OUT W16 W16/620 SITE ASSESSMENT W16 W16/630 INSTALLING INDUCTION-LOOP SYSTEMS GENERALLY W16 W16/650 INSTALLING FINAL AMPLIFIERS W16 W16/670 INSTALLING INDUCTION-LOOP CABLING W16 W16/680 INSTALLING MICS/LSZH LOOP CABLES W16 W16/690 INSTALLING MULTIPLE LOOPS W16 W16/700 INSTALLING LOOP PADS W16 W16/720 TRIAL LOOP W16 W16/760 INSTALLING ILLUMINATED REASSURANCE INDICATORS W16 W16/780 INSTALLING SIGNAGE W16 W16/810 TESTING AND COMMISSIONING GENERALLY W16 W16/820 SYSTEM RE-COMMISSIONING W16 W16/830 SUBJECTIVE TESTING W16 W16/840 EQUIPMENT LABELLING AND SYSTEM DIAGRAMS W16 W16/860 SPARES W16 W16/870 DOCUMENTATION W16 W16/880 MAINTENANCE W16 W17 INFRARED LISTENING SYSTEMS W W17/110 INFRARED LISTENING SYSTEMS W17 W17/130 CABLING AND CONTAINMENT FOR INFRARED RADIATORS W17 W17/210 DESIGN W17 W17/220 SITE ASSESSMENT W17 W17/310 MICROPHONES W17 W17/320 MODULATORS W17 W17/330 INFRARED RADIATORS W17 W17/340 HEADSETS W17 W17/350 STETHOSETS W17 W17/360 BODYPACK RECEIVERS W17 W17/370 INDUCTION COUPLERS W17 W17/380 SIGNAGE W17 W17/390 COAXIAL CABLE W17 W17/610 STRIPPING OUT W17 W17/620 INSTALLING MODULATORS W17 W17/630 INSTALLING INFRARED RADIATORS W17 W17/640 INSTALLING SIGNAGE W17 W17/910 DOCUMENTATION W17 W17/920 WALK TEST W17 W17/930 MAINTENANCE W17 W20 TELEVISION AND RADIO DISTRIBUTION SYSTEMS W W20/110 TELEVISION DISTRIBUTION SYSTEM W20 W20/120 CABLING AND CONTAINMENT W20 W20/210 DESIGN W20 W20/220 PERFORMANCE W20 W20/230 WIND RESISTANCE OF ANTENNAE W20 W20/240 INTERFACE TO OTHER SERVICES W20 W20/310 UHF ANTENNAE W20 W20/320 FM ANTENNAE W20 W20/330 DAB ANTENNAE W20 W20/340 SATELLITE DISHES W20 W20/350 MASTHEAD AMPLIFIERS W20 W20/360 EQUALIZERS W20 W20/370 LAUNCH AMPLIFIERS W20 W20/380 MULTISWITCHES W20 W20/390 DIPLEXERS W20 W20/400 SPLITTERS W20 W20/410 TELEVISION OUTLETS W20 W20/420 COAXIAL CABLE W20 W20/610 STRIPPING OUT W20 W20/620 INSTALLING ANTENNAE AND DISHES W20 W20/640 INSTALLING CABLING W20 W20/650 INSTALLING AMPLIFIERS W20 W20/660 INSTALLING OUTLET PLATES W20 W20/670 CONNECTION TO LIGHTNING PROTECTION SYSTEM W20 W20/910 TESTING AND INSPECTION W20 W20/920 DOCUMENTATION W20 W20/930 SPARES AND CONSUMABLES W20 W20/940 MAINTENANCE W20 W30 TELECOMMUNICATIONS SYSTEMS W W30/110 TELECOMMUNICATIONS SYSTEM W30 W30/120 CONTAINMENT W30 W30/210 DESIGN W30 W30/235 CAPACITY OF SYSTEM W30 W30/240 TELECOMMUNICATIONS OUTLETS W30 W30/250 RESILIENCE W30 W30/260 INTERCONNECTIONS WITH OTHER SYSTEMS W30 W30/310 PRODUCTS GENERALLY W30 W30/320 MAIN SWITCHING DEVICE W30 W30/330 DISTRIBUTION PANELS W30 W30/335 COPPER VOICE CABLES W30 W30/340 FUNCTIONAL EARTH CABLES W30 W30/345 OPTICAL FIBRE CABLES W30 W30/350 TELECOMMUNICATION OUTLETS W30 W30/360 TERMINAL DEVICES W30 W30/365 PAYPHONES W30 W30/370 ACOUSTIC HOODS W30 W30/375 OPERATOR CONSOLES W30 W30/380 CALL INFORMATION LOGGING EQUIPMENT W30 W30/385 EXTENSION RINGERS W30 W30/610 STRIPPING OUT W30 W30/615 INSTALLATION GENERALLY W30 W30/620 CONNECTION TO THE PUBLIC TELEPHONE NETWORK W30 W30/625 INSTALLING MAIN SWITCHING DEVICES W30 W30/640 INSTALLING DISTRIBUTION PANELS W30 W30/660 INSTALLING COPPER VOICE CABLING W30 W30/665 INSTALLING FUNCTIONAL EARTH CABLING W30 W30/670 INSTALLING OPTICAL FIBRE CABLING W30 W30/680 INSTALLING TELECOMMUNICATIONS OUTLETS W30 W30/690 INSTALLING TERMINAL DEVICES W30 W30/700 INSTALLING PAYPHONES AND ACOUSTIC HOODS W30 W30/710 INSTALLING OPERATOR CONSOLES W30 W30/720 INSTALLING CALL INFORMATION LOGGING EQUIPMENT W30 W30/730 INSTALLING EXTENSION RINGERS W30 W30/810 TESTING AND INSPECTIONS W30 W30/820 DOCUMENTATION W30 W30/825 LABELLING W30 W30/830 SPARES AND CONSUMABLES W30 W30/840 MAINTENANCE W30 W31 DATA DISTRIBUTION SYSTEMS W W31/110 DATA DISTRIBUTION SYSTEM W31 W31/120 CONTAINMENT W31 W31/210 DESIGN W31 W31/230 CHANNEL PERFORMANCE W31 W31/240 TELECOMMUNICATIONS OUTLETS W31 W31/250 RESILIENCE W31 W31/260 CONNECTIONS WITH OTHER SYSTEMS W31 W31/290 NON LINEAR LOADS W31 W31/310 PRODUCTS GENERALLY W31 W31/320 BALANCED TWISTED-PAIR CABLES W31 W31/330 OPTICAL FIBRE CABLES W31 W31/340 COAXIAL CABLES W31 W31/370 HARDWARE CONNECTIONS GENERALLY W31 W31/380 COAXIAL CABLE CONNECTORS W31 W31/400 CABINET W31 W31/420 BALANCED TWISTED-PAIR CABLING PATCH PANELS W31 W31/430 PATCH CORDS W31 W31/440 BALANCED TWISTED-PAIR CABLE OUTLETS W31 W31/450 FIBRE OPTIC CABLE OUTLETS W31 W31/470 RJ-45 TO BT PLUG ADAPTORS W31 W31/480 WALL MOUNTED EQUIPMENT BACKBOARDS W31 W31/610 STRIPPING OUT W31 W31/615 SYSTEM INSTALLER W31 W31/620 INSTALLATION GENERALLY W31 W31/630 CABLE INSTALLATION GENERALLY W31 W31/640 SPARE CABLING W31 W31/650 INSTALLING OPTICAL FIBRE CABLING W31 W31/680 INSTALLING CONNECTING HARDWARE W31 W31/690 EARTHING AND BONDING W31 W31/720 INSTALLING CABINETS W31 W31/730 INSTALLING WALL MOUNTED EQUIPMENT W31 W31/770 CONNECTION TO THE PUBLIC TELEPHONE NETWORK W31 W31/780 INSTALLING TELECOMMUNICATIONS OUTLETS W31 W31/810 TESTING AND INSPECTIONS W31 W31/820 DOCUMENTATION W31 W31/830 SPARES AND CONSUMABLES W31 W31/840 MAINTENANCE W31 W31/850 LABELLING W31 W31/880 SYSTEM MANUFACTURERS WARRANTY W31 W40 ACCESS CONTROL SYSTEMS W W40/110 ACCESS CONTROL SYSTEM W40 W40/120 AUDIO INTERCOM SYSTEM W40 W40/130 VIDEO INTERCOM SYSTEM W40 W40/140 CABLING AND CONTAINMENT W40 W40/210 DESIGN W40 W40/220 ACCESS CONTROL POINTS W40 W40/230 CONNECTION TO FIRE DETECTION AND ALARM SYSTEMS W40 W40/240 INTEGRATION WITH OTHER ALARM AND SECURITY SYSTEMS W40 W40/310 MULTIPLE TECHNOLOGY CARDS W40 W40/320 PROXIMITY CARDS W40 W40/330 SMART CARDS W40 W40/340 SWIPE CARDS W40 W40/350 BIOMETRIC FINGERPRINT READERS W40 W40/360 PROXIMITY READERS W40 W40/370 SMART CARD READERS AND WRITERS W40 W40/380 SWIPE CARD READERS W40 W40/390 INTERCOM ENTRANCE PANELS W40 W40/400 ACCESS CONTROL CABLES W40 W40/410 ELECTRIC STRIKES AND FACEPLATES W40 W40/420 MAGNETIC LOCKS AND STRIKE PLATES W40 W40/430 SHEAR LOCKS AND STRIKE PLATES W40 W40/440 INTERCOM REMOTE HANDSETS W40 W40/450 ACCESS CONTROL SYSTEM CONTROLLERS W40 W40/455 DOOR CONTROLLERS W40 W40/460 PERSONAL COMPUTERS W40 W40/465 ACCESS CONTROL POINT STATUS MONITORING DEVICES W40 W40/470 CARD PRINTERS W40 W40/475 DIGITAL CAMERAS W40 W40/480 EMERGENCY BREAK GLASS UNITS W40 W40/490 REQUEST TO EXIT BUTTONS W40 W40/610 STRIPPING OUT W40 W40/620 INSTALLING ACCESS CONTROL SYSTEMS W40 W40/630 INSTALLING CABLING W40 W40/650 INSTALLING READERS W40 W40/690 INSTALLING INTERCOM SYSTEMS W40 W40/810 TESTING AND COMMISSIONING GENERALLY W40 W40/820 EQUIPMENT LABELLING AND SYSTEM DIAGRAMS W40 W40/830 AUDIO INTERCOM SYSTEM TESTING AND COMMISSIONING W40 W40/840 VIDEO INTERCOM TESTING AND COMMISSIONING W40 W40/850 DOCUMENTATION W40 W40/860 SPARES AND CONSUMABLES W40 W40/870 MAINTENANCE W40 W41 INTRUDER DETECTION AND ALARM SYSTEMS W W41/110 INTRUDER DETECTION AND ALARM SYSTEM W41 W41/210 DESIGN W41 W41/220 SYSTEM SETTING AND UNSETTING W41 W41/225 ZONING AND DEVICE IDENTIFICATION W41 W41/230 SPARE CAPACITY W41 W41/235 CONNECTION TO FIRE DETECTION AND ALARM SYSTEMS W41 W41/240 CONTINUOUS MONITORING W41 W41/242 POLICE RESPONSE W41 W41/244 INTEGRATION WITH OTHER ALARM AND SECURITY SYSTEMS W41 W41/246 INTEGRATION WITH CCTV SYSTEMS W41 W41/248 GRADE 3 AND GRADE 4 STANDBY PERIOD W41 W41/250 DIGITAL COMMUNICATORS W41 W41/252 DIRECT LINE SIGNALLING W41 W41/253 PREVENTION OF SETTING FOR GRADE 1 SYSTEMS W41 W41/255 PREVENTION OF SETTING FOR GRADE 2 SYSTEMS W41 W41/257 PREVENTION OF SETTING FOR GRADE 3 SYSTEMS W41 W41/259 SUPPLEMENTARY PROCESSING OF SIGNALS FOR GRADE 1 SYSTEMS W41 W41/261 SUPPLEMENTARY PROCESSING OF SIGNALS FOR GRADE 2 SYSTEMS W41 W41/263 SUPPLEMENTARY PROCESSING OF SIGNALS FOR GRADE 3 OR 4 SYSTEMS W41 W41/265 SUPPLEMENTARY INDICATIONS FOR GRADE 1 AND 2 SYSTEMS W41 W41/266 SUPPLEMENTARY INDICATIONS FOR GRADE 3 SYSTEMS W41 W41/268 SUPPLEMENTARY INDICATIONS FOR GRADE 4 SYSTEMS W41 W41/270 NOTIFICATION REQUIREMENTS FOR GRADE 1 SYSTEMS W41 W41/272 NOTIFICATION REQUIREMENTS FOR GRADE 2 SYSTEMS W41 W41/274 NOTIFICATION REQUIREMENTS FOR GRADE 3 SYSTEMS W41 W41/276 NOTIFICATION REQUIREMENTS FOR GRADE 4 SYSTEMS W41 W41/278 SUPPLEMENTARY TAMPER DETECTION FOR GRADE 1 SYSTEMS W41 W41/280 SUPPLEMENTARY TAMPER DETECTION FOR GRADE 2 SYSTEMS W41 W41/282 SUPPLEMENTARY TAMPER DETECTION FOR GRADE 3 SYSTEMS W41 W41/286 MONITORING SUBSTITUTION OF GRADE 1, 2 AND 3 SYSTEM COMPONENTS W41 W41/288 EVENT RECORDING FOR GRADE 1 SYSTEMS W41 W41/290 EVENT RECORDING FOR GRADE 2 SYSTEMS W41 W41/292 EVENT RECORDING FOR GRADE 3 SYSTEMS W41 W41/294 EVENT RECORDING FOR GRADE 4 SYSTEMS W41 W41/310 ACOUSTIC DETECTORS W41 W41/312 BEAM INTERRUPTION DEVICES W41 W41/314 CAPACITIVE PROXIMITY DETECTORS W41 W41/316 COMBINED PASSIVE INFRARED AND MICROWAVE DETECTORS W41 W41/317 COMBINED PASSIVE INFRARED AND ULTRASONIC DETECTORS W41 W41/318 DELIBERATELY OPERATED DEVICES W41 W41/319 MICROWAVE DETECTORS W41 W41/320 PASSIVE INFRARED DETECTORS W41 W41/322 PROTECTIVE SWITCHES W41 W41/326 ULTRASONIC DETECTORS W41 W41/328 VIBRATION DETECTORS W41 W41/330 VOLUMETRIC CAPACITIVE DETECTORS W41 W41/340 ELECTRONIC SOUNDERS W41 W41/345 LED CLUSTERS W41 W41/350 VIBRATING PAGERS W41 W41/355 XENON BEACONS W41 W41/360 EXTERNAL SOUNDERS W41 W41/400 CONTROL AND INDICATING EQUIPMENT (CIE) W41 W41/450 REMOTE KEYPADS W41 W41/480 MULTI-CORE INTRUDER ALARM CABLES W41 W41/610 STRIPPING OUT W41 W41/620 INSTALLING INTRUDER ALARM CONTROL AND INDICATING EQUIPMENT W41 W41/630 INSTALLING CABLES W41 W41/635 INSTALLING ACOUSTIC DETECTORS W41 W41/640 INSTALLING BEAM INTERRUPTION DEVICES W41 W41/645 INSTALLING CAPACITIVE PROXIMITY DEVICES W41 W41/650 INSTALLING COMBINED PASSIVE INFRARED AND MICROWAVE DETECTORS W41 W41/651 INSTALLING COMBINED PASSIVE INFRARED AND ULTRASONIC DETECTORS W41 W41/655 INSTALLING DELIBERATELY OPERATED DEVICES W41 W41/660 INSTALLING MICROWAVE DETECTORS W41 W41/665 INSTALLING PASSIVE INFRARED DETECTORS W41 W41/670 INSTALLING PROTECTIVE SWITCHES W41 W41/675 INSTALLING ULTRASONIC DETECTORS W41 W41/680 INSTALLING VIBRATION DETECTORS W41 W41/685 INSTALLING VOLUMETRIC CAPACITIVE DETECTORS W41 W41/690 INSTALLING ELECTRONIC SOUNDERS W41 W41/695 INSTALLING LED CLUSTERS W41 W41/700 INSTALLING XENON BEACONS W41 W41/710 INSTALLING REMOTE KEYPADS W41 W41/805 TESTING AND COMMISSIONING GENERALLY W41 W41/810 DEVICE IDENTIFICATION AND TESTING W41 W41/815 SYSTEM SOAK TESTING W41 W41/820 STANDBY BATTERY TESTING W41 W41/825 TESTING ACTUATION, INTEGRATION AND INTERFACING WITH ALARM AND SECURITY SYSTEMS W41 W41/830 MODIFICATIONS TO EXISTING INTRUDER DETECTION AND ALARM SYSTEMS W41 W41/835 DOCUMENTATION W41 W41/840 LOG BOOK W41 W41/845 SPARES AND CONSUMABLES W41 W41/850 MAINTENANCE W41 W44 CLOSED CIRCUIT TELEVISION SYSTEMS W W44/110 CCTV SYSTEM W44 W44/120 CABLING AND CONTAINMENT W44 W44/210 DESIGN W44 W44/215 REMOTE MONITORING W44 W44/220 CCTV ZONE W44 W44/230 ANALOGUE STORAGE W44 W44/240 DIGITAL STORAGE W44 W44/250 INTEGRATION WITH OTHER ALARM AND SECURITY SYSTEMS W44 W44/310 CAMERAS W44 W44/320 COVERT CAMERAS W44 W44/330 PAN AND TILT UNITS W44 W44/340 CONTROL MATRIX W44 W44/350 TELEMETRY TRANSMITTERS W44 W44/360 TELEMETRY RECEIVERS W44 W44/370 TIME LAPSE VIDEO RECORDERS W44 W44/380 DIGITAL VIDEO RECORDERS W44 W44/385 NETWORK VIDEO RECORDERS W44 W44/390 MONITORS W44 W44/400 CAMERA BRACKETS W44 W44/410 CCTV SIGNAGE W44 W44/420 EXTERNAL CAMERA HOUSINGS W44 W44/430 INTERNAL CAMERA HOUSINGS W44 W44/440 INFRARED ILLUMINATORS W44 W44/450 CAMERA MASTS W44 W44/460 VIDEO RECORDER CABINETS W44 W44/465 COAXIAL CABLE W44 W44/470 BALANCED TWISTED-PAIR CABLES W44 W44/480 CONCRETE FOR BASES W44 W44/610 STRIPPING OUT W44 W44/620 INSTALLING CLOSED CIRCUIT TELEVISION SYSTEMS W44 W44/630 INSTALLING CABLES W44 W44/635 INSTALLING CCTV CAMERAS W44 W44/640 INSTALLING CONTROLLERS W44 W44/645 INSTALLING TELEMETRY TRANSMITTERS AND RECEIVERS W44 W44/650 INSTALLING MONITORS W44 W44/655 INSTALLING DIGITAL VIDEO RECORDERS W44 W44/660 INSTALLING NETWORK VIDEO RECORDERS W44 W44/665 INSTALLING CAMERA BRACKETS W44 W44/675 INSTALLING INFRARED ILLUMINATORS W44 W44/680 INSTALLING VIDEO RECORDER CABINETS W44 W44/685 INSTALLING CAMERA MASTS W44 W44/690 INSTALLING CONCRETE BASES W44 W44/700 INSTALLING SIGNAGE W44 W44/810 CLOSED CIRCUIT TELEVISION SYSTEM TESTING AND COMMISSIONING W44 W44/815 TRAINING W44 W44/820 DOCUMENTATION W44 W44/830 SPARES AND CONSUMABLES W44 W44/840 MAINTENANCE W44 W50 FIRE DETECTION AND ALARM SYSTEMS W W50/110 FIRE DETECTION AND ALARM SYSTEM W50 W50/130 ASPIRATING DETECTION SYSTEMS W50 W50/210 DESIGN OF FIRE DETECTION AND ALARM SYSTEMS W50 W50/215 DESIGN OF ASPIRATING DETECTION SYSTEMS W50 W50/220 PERFORMANCE OF FIRE DETECTION AND ALARM SYSTEMS W50 W50/225 PERFORMANCE OF ASPIRATING DETECTION SYSTEMS W50 W50/230 SYSTEM CATEGORY L2 W50 W50/231 SYSTEM CATEGORY L5 W50 W50/232 SYSTEM CATEGORY P2 W50 W50/250 DETECTION ZONES W50 W50/255 ALARM ZONES W50 W50/260 ACTUATION OF FIRE PROTECTION SYSTEMS W50 W50/265 INTEGRATION WITH OTHER ALARM AND SECURITY SYSTEMS W50 W50/266 INTERFACES TO EQUIPMENT W50 W50/270 INTERFACE ISOLATION FOR TESTING PURPOSES W50 W50/275 ALARM FILTERING W50 W50/285 EXTERNAL ALARM SIGNALLING W50 W50/290 REMOTE SIGNALLING W50 W50/310 DETECTION DEVICES W50 W50/320 PRODUCTS FOR USE IN EXPLOSIVE GAS OR VAPOUR ATMOSPHERES W50 W50/330 PRODUCTS FOR USE IN EXPLOSIVE DUST ATMOSPHERES W50 W50/360 COMBUSTION GAS DETECTORS W50 W50/370 MANUAL CALL POINTS W50 W50/380 OPTICAL BEAM SMOKE DETECTORS W50 W50/390 POINT FLAME DETECTORS W50 W50/400 POINT HEAT DETECTORS W50 W50/410 POINT SMOKE DETECTORS W50 W50/420 ENHANCED FIRE RESISTING CABLING W50 W50/425 RADIO BASED EQUIPMENT W50 W50/430 STANDARD FIRE RESISTING CABLING W50 W50/435 SOUNDERS W50 W50/440 VIBRATING PILLOW PADS W50 W50/445 VIBRATING RADIO PAGERS W50 W50/447 TRANSMITTERS FOR VIBRATING RADIO PAGERS W50 W50/450 VISUAL ALARM SIGNAL DEVICES W50 W50/455 FULLY FUNCTIONAL REPEAT PANELS W50 W50/460 MAIN CONTROL AND INDICATING EQUIPMENT (CIE) W50 W50/465 POWER SUPPLY EQUIPMENT W50 W50/470 AUTOMATIC DOOR RELEASE MECHANISMS W50 W50/475 MIMIC PANELS W50 W50/480 REMOTE INDICATORS W50 W50/550 SHORT CIRCUIT ISOLATORS W50 W50/560 ZONE DIAGRAMS W50 W50/565 ASPIRATING SMOKE DETECTION EQUIPMENT W50 W50/605 STRIPPING OUT W50 W50/610 MODIFYING EXISTING FIRE DETECTION AND ALARM SYSTEMS W50 W50/620 WORKING IN AREAS PROTECTED BY FIRE DETECTION AND ALARM SYSTEMS W50 W50/640 RADIO COMMUNICATIONS SURVEY W50 W50/650 INSTALLING MAIN CONTROL AND INDICATING EQUIPMENT (CIE) W50 W50/660 INSTALLING CABLING W50 W50/670 INSTALLING POINT DETECTORS W50 W50/680 INSTALLING MANUAL CALL POINTS W50 W50/700 INSTALLING SOUNDERS W50 W50/705 INSTALLING VISUAL ALARM SIGNAL DEVICES W50 W50/710 INSTALLING SHORT CIRCUIT ISOLATORS W50 W50/720 INSTALLING END OF LINE DEVICES W50 W50/725 INSTALLING REMOTE INDICATORS W50 W50/730 INSTALLING TRANSMITTERS FOR VIBRATING RADIO PAGERS W50 W50/740 INSTALLING INTERFACES TO OTHER EQUIPMENT AND SYSTEMS W50 W50/750 INSTALLING ALL ZONE EVACUATION CONTROLS W50 W50/760 INSTALLING ASPIRATING SMOKE DETECTION SYSTEMS W50 W50/810 TESTING AND COMMISSIONING GENERALLY W50 W50/815 SYSTEM INFORMATION W50 W50/820 TESTING AND COMMISSIONING OF ASPIRATING SMOKE DETECTION SYSTEMS W50 W50/825 DEVICE IDENTIFICATION AND TESTING W50 W50/830 CABLE TESTING W50 W50/835 SYSTEM SOAK TESTING W50 W50/840 STANDBY BATTERY TESTING W50 W50/845 TESTING ACTUATION, INTEGRATION AND INTERFACING WITH ALARM AND SECURITY SYSTEMS W50 W50/850 MEASUREMENT OF SOUND PRESSURE LEVELS W50 W50/855 MEASUREMENT OF MESSAGE INTELLIGIBILITY W50 W50/860 MODIFICATIONS TO EXISTING FIRE DETECTION AND ALARM SYSTEMS W50 W50/865 CERTIFICATION W50 W50/870 DOCUMENTATION W50 W50/875 LOG BOOKS W50 W50/880 ACCEPTANCE CERTIFICATE W50 W50/890 SPARES AND CONSUMABLES W50 W50/895 MAINTENANCE W50 W51 VOICE ALARM SYSTEMS W W51/110 VOICE ALARM SYSTEM W51 W51/210 DESIGN W51 W51/220 PERFORMANCE W51 W51/225 ALARM SYSTEM TYPE V2 W51 W51/230 ALARM SYSTEM TYPE V3 W51 W51/235 ALARM SYSTEM TYPE V4 W51 W51/240 ALARM SYSTEM TYPE V5 W51 W51/245 LOUDSPEAKER ZONES W51 W51/250 INTEGRATION WITH FIRE DETECTION AND ALARM SYSTEM W51 W51/270 INTEGRATION WITH OTHER ALARM AND SECURITY SYSTEMS W51 W51/310 PRODUCTS GENERALLY W51 W51/311 PRODUCTS FOR USE IN EXPLOSIVE ATMOSPHERES W51 W51/313 RADIO BASED EQUIPMENT W51 W51/315 PRIMARY POWER SUPPLIES W51 W51/318 SECONDARY POWER SUPPLIES W51 W51/319 TERTIARY POWER SUPPLIES W51 W51/320 AUTOMATIC MESSAGE GENERATORS W51 W51/330 EMERGENCY MICROPHONES W51 W51/335 POWER AMPLIFIERS W51 W51/340 PRE-AMPLIFIERS W51 W51/345 CONTROL AND INDICATING EQUIPMENT W51 W51/350 MIMIC INDICATOR PANELS W51 W51/360 EQUIPMENT RACKS W51 W51/370 LOUDSPEAKERS W51 W51/380 AMBIENT NOISE SENSING EQUIPMENT W51 W51/385 AUTOMATIC GAIN CONTROL DEVICES W51 W51/390 AUXILIARY PASSIVE ELEMENTS W51 W51/395 EQUALIZERS W51 W51/410 LOUDSPEAKER PROTECTIVE CAGES W51 W51/420 LOUDSPEAKER REAR PROTECTIVE ENCLOSURES W51 W51/425 ENHANCED FIRE RESISTING CABLING W51 W51/430 STANDARD FIRE RESISTING CABLING W51 W51/610 STRIPPING OUT W51 W51/620 MODIFYING EXISTING VOICE ALARM SYSTEMS W51 W51/630 INSTALLATION GENERALLY W51 W51/635 INSTALLING EMERGENCY MICROPHONES W51 W51/640 INSTALLING CABLING W51 W51/650 INSTALLING EMERGENCY MICROPHONE CABLING W51 W51/660 INSTALLING CONTROL AND INDICATING EQUIPMENT W51 W51/670 INSTALLING EQUIPMENT RACKS W51 W51/680 INSTALLING LOUDSPEAKERS W51 W51/685 INSTALLING LOUDSPEAKER PROTECTIVE CAGES W51 W51/690 INSTALLING LOUDSPEAKER REAR PROTECTIVE ENCLOSURES W51 W51/695 SAMPLES W51 W51/810 LABELLING W51 W51/820 TESTING AND COMMISSIONING GENERALLY W51 W51/825 MEASUREMENT OF SOUND PRESSURE LEVELS W51 W51/830 MEASUREMENT OF MESSAGE INTELLIGIBILITY W51 W51/835 STANDBY BATTERY TESTING W51 W51/840 TESTING ACTUATION, INTEGRATION AND INTERFACING WITH OTHER SYSTEMS W51 W51/850 EQUIPMENT RACK KEYS W51 W51/860 SYSTEM RE-COMMISSIONING W51 W51/870 DOCUMENTATION W51 W51/880 MAINTENANCE W51 W53 ASSISTANCE CALL SYSTEMS W W53/110 ASSISTANCE CALL SYSTEM W53 W53/120 CABLING AND CONTAINMENT W53 W53/210 DESIGN W53 W53/220 INTEGRATION WITH OTHER ALARM AND SECURITY SYSTEMS W53 W53/230 INTERFACES TO EQUIPMENT W53 W53/320 RADIO BASED EQUIPMENT W53 W53/330 PULL CORDS W53 W53/335 DISABLED REFUGE OUTSTATIONS W53 W53/340 OVERDOOR INDICATORS W53 W53/350 REMOTE INDICATORS W53 W53/355 DISABLED REFUGE MASTER STATION W53 W53/360 ALARM INDICATION WITHIN ACCESSIBLE ACCOMMODATION W53 W53/370 RESET UNITS W53 W53/380 POWER SUPPLY UNITS W53 W53/390 BATTERY BACKUP SUPPLY W53 W53/393 ACOUSTIC HOODS W53 W53/395 PORTABLE COMMUNICATORS W53 W53/605 RADIO COMMUNICATIONS SURVEY W53 W53/610 STRIPPING OUT W53 W53/620 INSTALLING ASSISTANCE CALL SYSTEMS GENERALLY W53 W53/622 INSTALLING DISABLED REFUGE CALL SYSTEMS W53 W53/627 INSTALLING CABLES W53 W53/630 INSTALLING PULL CORDS W53 W53/633 INSTALLING DISABLED REFUGE MASTER STATIONS W53 W53/635 INSTALLING DISABLED REFUGE OUTSTATIONS W53 W53/640 INSTALLING OVERDOOR INDICATORS W53 W53/650 INSTALLING REMOTE INDICATORS W53 W53/670 INSTALLING RESET UNITS W53 W53/680 INSTALLING POWER SUPPLY UNITS W53 W53/690 INSTALLING BATTERY BACK UP SUPPLIES W53 W53/700 INSTALLING ACOUSTIC HOODS W53 W53/810 TESTING AND COMMISSIONING GENERALLY W53 W53/815 TESTING AND COMMISSIONING DISABLED REFUGE CALL SYSTEMS W53 W53/820 DOCUMENTATION W53 W55 NURSE CALL SYSTEMS W W55/110 NURSE CALL SYSTEM W55 W55/120 CABLING AND CONTAINMENT W55 W55/210 DESIGN W55 W55/220 MODE OF OPERATION W55 W55/310 PRODUCTS GENERALLY W55 W55/320 PATIENT HANDSETS W55 W55/330 PATIENT PULL CORDS W55 W55/340 NURSE EMERGENCY PULL-SWITCHES W55 W55/350 VISUAL SIGNALS W55 W55/370 POWER SUPPLY UNITS W55 W55/380 CALL INDICATOR PANELS W55 W55/610 STRIPPING OUT W55 W55/620 EXECUTION GENERALLY W55 W55/630 INSTALLATION OF PATIENT HANDSETS W55 W55/640 INSTALLATION OF PATIENT PULL CORDS W55 W55/650 INSTALLATION OF NURSE EMERGENCY PULL-SWITCHES W55 W55/660 INSTALLATION OF VISUAL SIGNALS W55 W55/670 INSTALLATION OF POWER SUPPLY UNITS W55 W55/680 INSTALLATION OF CALL INDICATOR PANELS W55 W55/810 TESTING AND COMMISSIONING W55 W55/820 DOCUMENTATION W55 W55/830 SPARES AND CONSUMABLES W55 W55/840 MAINTENANCE W55 W57 GAS DETECTION AND ALARM SYSTEMS W W57/110 GAS DETECTION AND ALARM SYSTEM W57 W57/210 DESIGN W57 W57/220 SENSITIVITY W57 W57/230 INTEGRATION WITH OTHER ALARM SYSTEMS W57 W57/240 INTERFACES TO EQUIPMENT W57 W57/250 INTERFACE ISOLATION FOR TESTING PURPOSES W57 W57/310 FIXED MONITORS W57 W57/320 PORTABLE MONITORS W57 W57/330 TRANSPORTABLE MONITORS W57 W57/340 REMOTE SAMPLING EQUIPMENT W57 W57/350 CONTROL PANEL W57 W57/360 ELECTRONIC SOUNDERS W57 W57/380 VISUAL ALARM SIGNAL DEVICES W57 W57/610 STRIPPING OUT W57 W57/620 MODIFYING EXISTING GAS DETECTION AND ALARM SYSTEMS W57 W57/630 INSTALLATION GENERALLY W57 W57/640 INSTALLING SENSORS W57 W57/650 INSTALLING FIXED MONITORS W57 W57/810 DOCUMENTATION W57 W57/820 SYSTEM INFORMATION W57 W57/830 SENSOR IDENTIFICATION AND TESTING W57 W57/840 TESTING ACTUATION, INTEGRATION AND INTERFACING WITH ALARM AND SECURITY SYSTEMS W57 W57/850 MODIFICATIONS TO EXISTING GAS DETECTION AND ALARM SYSTEMS W57 W57/860 SPARES AND CONSUMABLES W57 W57/870 MAINTENANCE W57 W58 WATER DETECTION AND ALARM SYSTEMS W W58/110 WATER PRESENCE DETECTION AND ALARM SYSTEM W58 W58/120 WATER LEAK DETECTION AND ALARM SYSTEM W58 W58/210 DESIGN W58 W58/220 ZONING AND IDENTIFICATION FOR WATER PRESENCE AND ALARM SYSTEM W58 W58/230 INTEGRATION WITH OTHER ALARM AND SECURITY SYSTEMS W58 W58/310 CABLE SENSORS W58 W58/320 PAD SENSORS W58 W58/330 PROBE SENSORS W58 W58/340 TAPE SENSORS W58 W58/345 PROGRAMMABLE CONTROL UNITS W58 W58/350 CONTROL PANELS W58 W58/355 PULSED OUTPUT WATER METERS W58 W58/360 ELECTRONIC SOUNDERS W58 W58/370 VISUAL ALARM SIGNAL DEVICES W58 W58/610 STRIPPING OUT W58 W58/620 MODIFYING EXISTING WATER DETECTION AND ALARM SYSTEM W58 W58/630 INSTALLING CABLE AND TAPE SENSORS W58 W58/640 INSTALLING POWER SUPPLIES W58 W58/650 INSTALLING PAD SENSORS W58 W58/660 INSTALLING PROBE SENSORS W58 W58/665 INSTALLING PULSED OUTPUT WATER METERS W58 W58/670 INSTALLING CONTROL PANELS W58 W58/675 INSTALLING PROGRAMMABLE CONTROL UNITS W58 W58/680 INSTALLING SOUNDERS W58 W58/910 DOCUMENTATION W58 W58/920 SYSTEM INFORMATION FOR WATER PRESENCE DETECTION AND ALARM SYSTEM W58 W58/930 SENSOR IDENTIFICATION AND TESTING W58 W58/940 BATTERY BACK UP TESTING W58 W58/950 TESTING ACTUATION, INTEGRATION AND INTERFACING WITH ALARM AND SECURITY SYSTEMS W58 W58/960 MODIFICATIONS W58 W58/970 SPARES AND CONSUMABLES FOR WATER PRESENCE DETECTION AND ALARM SYSTEM W58 W58/980 MAINTENANCE W58 W60 LIGHTNING PROTECTION SYSTEMS W W60/110 BUILDING CONSTRUCTION FOR INFORMATION W60 W60/120 LIGHTNING PROTECTION SYSTEM W60 W60/210 DESIGN W60 W60/310 AIR TERMINALS W60 W60/320 ALUMINIUM TAPE W60 W60/330 ALUMINIUM SOLID CIRCULAR CONDUCTORS W60 W60/340 COPPER TAPE W60 W60/350 COPPER SOLID CIRCULAR CONDUCTORS W60 W60/360 EARTH PLATES W60 W60/370 EARTH RODS W60 W60/390 RING EARTH ELECTRODES W60 W60/400 ANTI-VANDAL GUARDS W60 W60/410 CONNECTION COMPONENTS W60 W60/415 EARTH ROD INSPECTION PITS W60 W60/420 METALLIC DIRECT CONTACT CLIPS W60 W60/430 NON-METALLIC DIRECT CONTACT CLIPS W60 W60/440 NOTICES AND LABELS W60 W60/445 SOIL CONDITIONING AGENTS W60 W60/610 STRIPPING OUT W60 W60/620 EXISTING INSTALLATIONS W60 W60/630 INSTALLING LIGHTNING PROTECTION SYSTEMS W60 W60/640 INSTALLING AIR TERMINALS W60 W60/650 INSTALLING TAPES W60 W60/660 INSTALLING EARTH RODS W60 W60/680 INSTALLING EARTH PLATES W60 W60/690 INSTALLING EARTH ROD INSPECTION PITS W60 W60/700 INSTALLING RING EARTH ELECTRODES W60 W60/710 INSTALLING TEST JOINTS W60 W60/715 BONDING W60 W60/720 DISSIMILAR METALS W60 W60/730 INSTALLING SOIL CONDITIONING AGENTS W60 W60/740 INSTALLING ANTI-VANDAL GUARDS W60 W60/750 INSTALLING NOTICES AND LABELS W60 W60/810 INSPECTION AND TESTING W60 W60/840 DOCUMENTATION W60 W60/850 MAINTENANCE W60 W73 SWIMMING POOL TIMING AND SCORING SYSTEMS W W73/110 SWIMMING POOL TIMING AND SCORING SYSTEM W73 W73/120 DISPLAY SYSTEM W73 W73/130 CABLING AND CONTAINMENT W73 W73/210 DESIGN W73 W73/310 START CONTROL UNITS W73 W73/320 LOUDSPEAKERS W73 W73/330 STARTING STROBE LIGHTS W73 W73/340 MICROPHONES W73 W73/350 HEADSETS W73 W73/360 STARTING PLATFORMS W73 W73/370 MANUAL PUSH BUTTONS W73 W73/380 TOUCH PADS W73 W73/390 TIMING SYSTEM CONTROLLERS W73 W73/400 RESULTS PRINTERS W73 W73/410 CONNECTION BOXES W73 W73/420 ELECTRONIC SCOREBOARDS W73 W73/610 STRIPPING OUT W73 W73/620 INSTALLATION GENERALLY W73 W73/630 INSTALLING LOUDSPEAKERS W73 W73/640 INSTALLING STARTING STROBE LIGHTS W73 W73/650 INSTALLING ELECTRONIC SCOREBOARDS W73 W73/660 INSTALLING CABLE CONTAINMENT W73 W73/670 INSTALLING CONNECTION BOXES W73 W73/680 INSTALLING CABLING W73 W73/810 TESTING AND COMMISSIONING W73 W73/820 DOCUMENTATION W73 W73/830 SPARES AND CONSUMABLES W73 W73/840 MAINTENANCE W73 W90 COMMUNICATIONS AND SECURITY SYSTEMS – DOMESTIC W W90/110 TELEVISION DISTRIBUTION SYSTEM W90 W90/120 FIRE DETECTION AND ALARM SYSTEM W90 W90/130 ACCESS CONTROL SYSTEM W90 W90/140 AUDIO INTERCOM SYSTEM W90 W90/150 VIDEO INTERCOM SYSTEM W90 W90/160 INTRUDER DETECTION AND ALARM SYSTEM W90 W90/170 CLOSED CIRCUIT TELEVISION (CCTV) SYSTEM W90 W90/210 DESIGN REQUIREMENTS W90 W90/215 DESIGN OF TELEVISION DISTRIBUTION SYSTEMS W90 W90/220 DESIGN OF FIRE DETECTION AND ALARM SYSTEMS W90 W90/225 DESIGN OF ACCESS CONTROL SYSTEMS W90 W90/230 DESIGN OF INTRUDER DETECTION AND ALARM SYSTEMS W90 W90/235 DESIGN OF CLOSED CIRCUIT TELEVISION SYSTEMS W90 W90/240 CLOSED CIRCUIT TELEVISION ZONE W90 W90/245 CLOSED CIRCUIT TELEVISION ANALOGUE STORAGE W90 W90/250 CLOSED CIRCUIT TELEVISION DIGITAL STORAGE W90 W90/310 TELEVISION ANTENNAE W90 W90/315 COAXIAL CABLES W90 W90/317 SATELLITE DISHES W90 W90/320 TELEVISION OUTLETS W90 W90/330 SMOKE ALARMS W90 W90/332 CARBON MONOXIDE FIRE DETECTOR ALARMS W90 W90/335 CARBON MONOXIDE ALARMS W90 W90/340 LOW VOLTAGE CABLE W90 W90/345 SWIPE CARDS W90 W90/350 PROXIMITY CARDS W90 W90/360 PROXIMITY READERS W90 W90/362 PIN KEYPADS W90 W90/365 INTERCOM ENTRANCE PANELS W90 W90/370 INTERCOM REMOTE HANDSETS W90 W90/380 INTRUDER ALARM CONTROL PANEL W90 W90/385 INTRUDER ALARM CABLES W90 W90/390 INTERNAL SOUNDERS W90 W90/395 EXTERNAL SOUNDERS W90 W90/410 REMOTE KEYPADS W90 W90/412 MICROWAVE DETECTORS W90 W90/415 PASSIVE INFRA RED DETECTORS W90 W90/420 ULTRASONIC DETECTORS W90 W90/425 DUAL TECHNOLOGY DETECTORS W90 W90/430 DOOR CONTACTS W90 W90/435 PANIC BUTTONS W90 W90/440 DIGITAL COMMUNICATORS W90 W90/445 DIRECT LINE SIGNALLING W90 W90/448 ANALOGUE RECORDING EQUIPMENT W90 W90/450 CLOSED CIRCUIT TELEVISION CAMERAS W90 W90/455 CLOSED CIRCUIT TELEVISION CONTROL MATRIX W90 W90/458 DIGITAL RECORDING EQUIPMENT W90 W90/460 CLOSED CIRCUIT TELEVISION MONITORS W90 W90/600 INSTALLATION GENERALLY W90 W90/605 INSTALLING CABLES GENERALLY W90 W90/610 INSTALLING OUTLETS AND EQUIPMENT GENERALLY W90 W90/620 INSTALLING TELEVISION ANTENNAE W90 W90/630 INSTALLING TELEVISION CABLING AND OUTLETS W90 W90/640 INSTALLING SMOKE ALARMS W90 W90/650 INSTALLING CARBON MONOXIDE ALARMS W90 W90/670 INSTALLING ACCESS CONTROL SYSTEMS W90 W90/680 INSTALLING ACCESS CONTROL CABLES W90 W90/700 INSTALLING INTERCOM SYSTEMS W90 W90/720 INSTALLING INTRUDER DETECTION AND ALARMS SYSTEMS W90 W90/730 INSTALLING INTRUDER ALARM CABLES W90 W90/750 INSTALLING CLOSED CIRCUIT TELEVISION SYSTEMS W90 W90/760 INSTALLING CLOSED CIRCUIT TELEVISION CABLES W90 W90/800 TELEVISION DISTRIBUTION SYSTEMS TESTING AND COMMISSIONING W90 W90/810 FIRE ALARM DETECTION AND ALARM SYSTEM TESTING AND COMMISSIONING W90 W90/820 CARBON MONOXIDE ALARM TESTING AND COMMISSIONING W90 W90/830 ACCESS CONTROL SYSTEM TESTING AND COMMISSIONING W90 W90/840 AUDIO INTERCOM SYSTEM TESTING AND COMMISSIONING W90 W90/850 VIDEO INTERCOM TESTING AND COMMISSIONING W90 W90/860 INTRUDER DETECTION AND ALARM SYSTEM TESTING AND COMMISSIONING W90 W90/870 CLOSED CIRCUIT TELEVISION SYSTEM TESTING AND COMMISSIONING W90 W90/880 DOCUMENTATION W90 W90/890 MAINTENANCE W90 X TRANSPORT SYSTEMS X10 LIFT SYSTEMS X X10/110 LIFT SYSTEM X10 X10/120 ELECTRIC A.C. TRACTION DRIVE SPEED CONTROL AND LIFT CAR ARRANGEMENT X10 X10/130 HYDRAULIC DRIVE SPEED CONTROL AND LIFT CAR ARRANGEMENT X10 X10/150 BUILDING DESCRIPTION X10 X10/160 HEADROOM X10 X10/170 24 H COMMUNICATION LINK X10 X10/180 LIFT SHAFT AND MACHINE ROOM CABLING AND CONTAINMENT X10 X10/185 ELECTRICAL SUPPLIES TO FIRE FIGHTING AND EXACUATION LIFTS X10 X10/210 DESIGN X10 X10/220 LIFT SYSTEM PERFORMANCE X10 X10/230 EXPRESS ZONES X10 X10/240 CONTROL OF LIFT GROUPS X10 X10/250 NOISE CRITERIA X10 X10/260 CONNECTION TO FIRE DETECTION AND ALARM SYSTEMS X10 X10/270 INTEGRATION WITH ALARM AND SECURITY SYSTEMS X10 X10/280 ELECTRICAL INSTALLATION X10 X10/310 PRODUCTS GENERALLY X10 X10/320 LIFT CARS X10 X10/330 LIFT CAR DIMENSIONS X10 X10/340 LIFT CAR AND LANDING DOORS, FRAMES AND SILLS X10 X10/360 MATERIALS AND FINISHES X10 X10/370 LIFT WELL GUIDE RAILS X10 X10/380 CONTROL BUTTONS X10 X10/390 ENHANCED CAR TOP CONTROLS X10 X10/410 ILLUMINATED LIFT CALL BUTTONS X10 X10/420 ILLUMINATED LANDING INDICATORS X10 X10/430 LIFT CONTROL PREFERENTIAL SERVICES X10 X10/440 LIFT MONITORING AND CONTROLS X10 X10/450 INVERTER DRIVEN SYSTEMS X10 X10/460 VOICE SYNTHESIZED ANNOUNCEMENTS X10 X10/470 EMERGENCY LIFT RAISING AND LOWERING EQUIPMENT X10 X10/480 PROTECTIVE QUILTS X10 X10/610 STRIPPING OUT X10 X10/620 LIFT WELL X10 X10/630 INSTALLING CONTROL CABINETS FOR MACHINE ROOM-LESS LIFTS X10 X10/640 INSTALLING CAR TOP CONTROLS X10 X10/650 INSTALLING TRACE HEATING X10 X10/660 INSTALLING HYDRAULIC DRIVES X10 X10/670 INSTALLING LANDING CALL BUTTONS X10 X10/680 INSTALLING ILLUMINATED LIFT CALL BUTTONS X10 X10/690 INSTALLING LIFT POSITION INDICATORS X10 X10/710 INSTALLING CONTROL CABINETS X10 X10/720 MACHINE ROOMS X10 X10/730 INSTALLING PROTECTIVE QUILT CABINETS X10 X10/810 TESTING AND COMMISSIONING X10 X10/820 TESTING AND COMMISSIONING OF FIRE FIGHTING LIFTS X10 X10/830 NOISE MEASUREMENT X10 X10/840 ELECTRICAL INSPECTION AND TESTING X10 X10/850 NOTICES AND INSTRUCTIONS X10 X10/855 EQUIPMENT LABELLING X10 X10/860 SPARES X10 X10/870 DOCUMENTATION X10 X10/875 TRAINING X10 X10/880 ROPE INSPECTION AND ADJUSTMENT X10 X10/890 MAINTENANCE X10 X12 VERTICAL PLATFORM LIFT SYSTEMS X X12/110 VERTICAL PLATFORM LIFT SYSTEM X12 X12/150 BUILDING DESCRIPTION X12 X12/210 DESIGN X12 X12/220 SYSTEM PERFORMANCE X12 X12/310 PRODUCTS GENERALLY X12 X12/320 INDEPENDENT SUPPORT STRUCTURE X12 X12/330 LIFTWAY FULL ENCLOSURE X12 X12/340 LIFTWAY PARTIAL ENCLOSURE X12 X12/350 PLATFORM X12 X12/360 BARRIERS TO PLATFORM X12 X12/370 DOORS AND GATES TO LANDINGS X12 X12/380 BRIDGE FROM PLATFORM X12 X12/390 RAMP X12 X12/400 POWER PACK X12 X12/410 SECONDARY POWER X12 X12/420 LIGHTING X12 X12/430 OPERATIONAL CONTROLS X12 X12/440 EMERGENCY CONTROLS X12 X12/450 ACCESS CONTROLS X12 X12/460 SIGNS AND NOTICES X12 X12/610 STRIPPING OUT X12 X12/620 INSTALLATION GENERALLY X12 X12/630 LAYOUT AND LOCATION X12 X12/640 MACHINE ROOM X12 X12/650 PIT X12 X12/910 TESTING AND COMMISSIONING X12 X12/920 ELECTRICAL INSPECTION AND TESTING X12 X12/930 NOTICES AND INSTRUCTIONS X12 X12/935 EQUIPMENT LABELLING X12 X12/940 SPARES AND CONSUMABLES X12 X12/970 DOCUMENTATION X12 X12/975 TRAINING X12 X12/980 MAINTENANCE X12 X13 INCLINED STAIRLIFT SYSTEMS X X13/110 INCLINED CUSTOM STAIRLIFT SYSTEM X13 X13/120 INCLINED STANDARD STAIRLFT SYSTEM X13 X13/210 DESIGN X13 X13/215 CONTEXT X13 X13/220 BUILDING DESCRIPTION X13 X13/230 OPERATIONAL PERFORMANCE X13 X13/310 PRODUCTS GENERALLY X13 X13/315 INCLINED STANDARD STAIRLIFT X13 X13/320 RAILS X13 X13/330 CHAIRS X13 X13/340 STANDING PLATFORMS X13 X13/350 WHEELCHAIR PLATFORMS X13 X13/355 PLATFORM MOUNTED ENCLOSURES X13 X13/360 BRIDGING PLATFORMS X13 X13/410 PRIMARY POWER - DEDICATED MAINS X13 X13/420 PRIMARY POWER - BATTERY X13 X13/430 SECONDARY POWER X13 X13/440 OPERATIONAL CONTROLS X13 X13/450 EMERGENCY CONTROLS X13 X13/460 ACCESS CONTROLS X13 X13/470 24 H COMMUNICATIONS SYSTEMS X13 X13/480 SIGNS AND NOTICES X13 X13/510 PROPOSALS X13 X13/520 SHOP DRAWINGS X13 X13/530 FACTORY INPSPECTIONS AND TESTING X13 X13/610 STRIPPING OUT X13 X13/620 INSTALLATION GENERALLY X13 X13/630 LAYOUT AND LOCATION X13 X13/910 TESTING AND COMMISSIONING X13 X13/920 ELECTRICAL INSPECTION AND TESTING X13 X13/925 NOTICES, INSTRUCTIONS AND CERTIFICATES X13 X13/930 EQUIPMENT LABELLING X13 X13/935 SPARES AND CONSUMABLES X13 X13/940 TRAINING X13 X13/945 MAINTENANCE X13 X15 ESCALATOR AND MOVING WALK SYSTEMS X X15/110 ESCALATOR SYSTEM X15 X15/120 MOVING WALK SYSTEM X15 X15/210 DESIGN X15 X15/220 PERFORMANCE X15 X15/230 NOISE CRITERIA X15 X15/240 CONNECTION TO FIRE DETECTION AND ALARM SYSTEMS X15 X15/250 INTEGRATION WITH SECURITY AND SAFETY SYSTEMS X15 X15/260 ELECTRICAL INSTALLATION X15 X15/310 PRODUCTS GENERALLY X15 X15/320 ELECTRIC DRIVES X15 X15/330 TREADWAY STEPS X15 X15/340 TREADWAY BELTS X15 X15/345 TREADWAY PALLETS X15 X15/350 LANDING COMB PLATES X15 X15/360 LANDING COVER PLATES X15 X15/370 BALUSTRADE PANELS X15 X15/380 DECKING X15 X15/390 HANDRAILS X15 X15/410 SKIRTINGS X15 X15/430 EXTERNAL CLADDING X15 X15/450 EMERGENCY STOP BUTTONS X15 X15/470 HAND WINDING EQUIPMENT X15 X15/480 SOLID GUARDS AT CEILING INTERSECTIONS X15 X15/495 SAMPLES X15 X15/610 STRIPPING OUT X15 X15/620 INSTALLATION GENERALLY X15 X15/630 MACHINE SPACES X15 X15/640 POWER SUPPLIES X15 X15/650 INSTALLING INTERFACES TO OTHER EQUIPMENT AND SYSTEMS X15 X15/810 CLEANING AND GENERAL INSPECTIONS X15 X15/820 TESTING AND COMMISSIONING GENERALLY X15 X15/830 DOCUMENTATION X15 X15/840 NOISE MEASUREMENT X15 X15/850 ELECTRICAL INSPECTION AND TESTING X15 X15/855 SIGNS AND NOTICES X15 X15/860 INSTRUCTIONS X15 X15/870 SPARES AND CONSUMABLES X15 X15/875 SPARE TOOLS X15 X15/880 MAINTENANCE X15 X31 PNEUMATIC DOCUMENT CONVEYING SYSTEMS X X31/110 PNEUMATIC DOCUMENT CONVEYING SYSTEM X31 X31/210 DESIGN X31 X31/310 STATIONS X31 X31/320 BLOWERS X31 X31/330 DIVERTERS X31 X31/340 CARRIERS X31 X31/350 PIPELINES X31 X31/360 SYSTEM CONTROL X31 X31/610 STRIPPING OUT X31 X31/620 INSTALLING STATIONS X31 X31/630 INSTALLING BLOWERS X31 X31/640 INSTALLING DIVERTERS X31 X31/650 INSTALLING PIPELINE AND FITTINGS X31 X31/910 CLEANING X31 X31/920 TESTING X31 X31/930 DOCUMENTATION X31 Y GENERAL ENGINEERING SERVICES Y10 PIPELINES Y Y10/110 STEEL PIPELINES Y10 Y10/120 COPPER PIPELINES Y10 Y10/130 PLASTICS WATER PIPELINES Y10 Y10/132 PLASTICS GASEOUS FUELS PIPELINES Y10 Y10/134 PLASTICS HEATING PIPELINES Y10 Y10/136 PLASTICS CONDENSATE DRAINAGE PIPELINES Y10 Y10/138 PLASTICS TREATED WATER PIPELINES Y10 Y10/140 STAINLESS STEEL PIPELINES Y10 Y10/150 GLASS PIPELINES Y10 Y10/160 PRE-INSULATED PIPELINES Y10 Y10/170 MULTILAYER PIPELINES Y10 Y10/310 STEEL TUBES Y10 Y10/320 JOINTING MATERIALS FOR STEEL TUBES Y10 Y10/330 FITTINGS FOR STEEL TUBES Y10 Y10/340 COPPER TUBES Y10 Y10/350 JOINTING MATERIALS FOR COPPER TUBES Y10 Y10/360 FITTINGS FOR COPPER TUBES Y10 Y10/371 POLYBUTYLENE (PB) TUBES Y10 Y10/373 POLYETHYLENE (PE) TUBES Y10 Y10/375 CROSS LINKED POLYETHYLENE (PE-X) TUBES Y10 Y10/377 POLYPROPYLENE (PP) TUBES Y10 Y10/379 CHLORINATED POLYVINYLCHLORIDE (PVC-C) TUBES Y10 Y10/381 UNPLASTICIZED POLYVINYLCHLORIDE (PVC-U) TUBES Y10 Y10/385 JOINTING MATERIALS FOR PLASTICS TUBES Y10 Y10/390 STAINLESS STEEL TUBES Y10 Y10/400 FITTINGS FOR STAINLESS STEEL TUBES Y10 Y10/410 GLASS TUBES Y10 Y10/420 FITTINGS FOR GLASS TUBES Y10 Y10/430 MASKING PLATES Y10 Y10/440 PRE-INSULATED PIPES Y10 Y10/450 MULTILAYER PIPES Y10 Y10/490 PIPELINE SUPPORTS Y10 Y10/605 PIPELINES INSTALLATION GENERALLY Y10 Y10/610 SPACING OF PIPELINES Y10 Y10/625 PIPELINE FITTINGS Y10 Y10/630 PIPELINE SLEEVES Y10 Y10/635 DISSIMILAR METALS Y10 Y10/640 ANCHORS GENERALLY Y10 Y10/645 ANCHORS FOR STEEL PIPES Y10 Y10/650 ANCHORS FOR COPPER PIPES Y10 Y10/655 ANCHORS FOR PVC PIPES Y10 Y10/660 SLIDE GUIDES Y10 Y10/665 WELDING STEEL PIPEWORK GENERALLY Y10 Y10/670 FLANGED JOINTS IN STEEL PIPES Y10 Y10/675 SCREWED JOINTS IN STEEL PIPES Y10 Y10/680 MECHANICAL JOINTS IN GROOVED STEEL AND STAINLESS STEEL PIPES Y10 Y10/690 BRAZED JOINTS IN COPPER AND COPPER ALLOY PIPES Y10 Y10/700 CAPILLARY JOINTS IN COPPER PIPES Y10 Y10/710 COMPRESSION JOINTS IN COPPER PIPES Y10 Y10/715 MECHANICAL JOINTS IN GROOVED COPPER PIPES Y10 Y10/720 BRAZED JOINTS IN STAINLESS STEEL PIPES Y10 Y10/725 CAPILLARY JOINTS IN STAINLESS STEEL PIPES Y10 Y10/730 COMPRESSION JOINTS IN STAINLESS STEEL PIPES Y10 Y10/745 JOINTS IN PVC PIPES Y10 Y10/750 FUSION JOINTS IN POLYETHYLENE PIPES Y10 Y10/755 MECHANICAL FITTINGS FOR POLYETHYLENE PIPES Y10 Y10/760 COUPLINGS FOR GLASS PIPES Y10 Y10/765 PROTECTION OF UNDERGROUND PIPEWORK Y10 Y10/770 PROTECTION OF BURIED PIPES Y10 Y10/810 GENERAL INSPECTION AND TESTING Y10 Y11 PIPELINE ANCILLARIES Y Y11/110 PIPELINE ANCILLARIES FOR INCOMING MAINS WATER SUPPLY Y11 Y11/120 PIPELINE ANCILLARIES FOR HOT AND COLD WATER SUPPLY Y11 Y11/130 PIPELINE ANCILLARIES FOR HEATING SYSTEMS Y11 Y11/140 PIPELINE ANCILLARIES FOR CHILLED WATER AND CONDENSER WATER SYSTEMS Y11 Y11/150 PIPELINE ANCILLARIES FOR HEAT PUMP SYSTEMS Y11 Y11/170 PIPELINE ANCILLARIES FOR FIRE HOSE REEL SYSTEMS Y11 Y11/180 PIPELINE ANCILLARIES FOR SWIMMING POOL WATER TREATMENT SYSTEMS Y11 Y11/302 CONNECTIONS FOR ANCILLARIES Y11 Y11/305 WATER SUPPLY - DRAW OFF TAPS AND STOP VALVES Y11 Y11/307 WATER SUPPLY - GATE VALVES FOR WATERWORKS Y11 Y11/309 WATER SUPPLY - STOP VALVES FOR POTABLE WATER Y11 Y11/311 WATER SUPPLY - STOP VALVES, UNDERGROUND Y11 Y11/315 FLOAT OPERATED VALVES, DELAYED ACTION Y11 Y11/317 FLOAT OPERATED VALVES, DIAPHRAGM TYPE, COPPER ALLOY BODY Y11 Y11/319 FLOAT OPERATED VALVES, DIAPHRAGM TYPE, PLASTICS BODY Y11 Y11/321 FLOAT OPERATED VALVES, PISTON TYPE Y11 Y11/323 FLOATS FOR BALL VALVES Y11 Y11/331 ISOLATING VALVES - BALL VALVES, CAST IRON OR STEEL Y11 Y11/333 ISOLATING VALVES - BALL VALVES Y11 Y11/335 ISOLATING VALVES - BUTTERFLY VALVES Y11 Y11/337 ISOLATING VALVES - DIAPHRAGM VALVES Y11 Y11/339 ISOLATING VALVES - GATE VALVES, CAST IRON Y11 Y11/341 ISOLATING VALVES - GATE VALVES, COPPER ALLOY Y11 Y11/343 ISOLATING VALVES - GLOBE VALVES, CARBON STEEL Y11 Y11/345 ISOLATING VALVES - GLOBE VALVES, CAST IRON Y11 Y11/347 ISOLATING VALVES - GLOBE VALVES, COPPER ALLOY Y11 Y11/353 CHECK VALVES, CAST IRON Y11 Y11/355 CHECK VALVES, LIFT TYPE Y11 Y11/357 CHECK VALVES, SWING TYPE Y11 Y11/359 CHECK VALVES - GLOBE STOP AND CHECK VALVES, CARBON STEEL Y11 Y11/365 REGULATING VALVES - DOUBLE Y11 Y11/367 REGULATING VALVES - FLOW MEASURING DEVICES Y11 Y11/372 TEMPERING VALVES Y11 Y11/375 THERMOSTATIC MIXING VALVES Y11 Y11/377 THERMOSTATIC MIXING VALVES FOR USE IN CARE ESTABLISHMENTS Y11 Y11/379 THERMOSTATIC MIXING VALVES, LOW PRESSURE Y11 Y11/385 RADIATOR VALVES Y11 Y11/387 THERMOSTATIC RADIATOR VALVES Y11 Y11/401 DRAINING AND VENTING DEVICES - AUTOMATIC AIR VENTS Y11 Y11/403 DRAINING AND VENTING DEVICES - DRAINING TAPS Y11 Y11/405 DRAINING AND VENTING DEVICES - THREE-WAY VENT COCKS Y11 Y11/411 EXPANSION DEVICES - EXPANSION COMPENSATORS, ANGULAR Y11 Y11/413 EXPANSION DEVICES - EXPANSION COMPENSATORS, AXIAL Y11 Y11/415 EXPANSION DEVICES - EXPANSION COMPENSATORS, LATERAL Y11 Y11/421 VIBRATION ISOLATION - FLEXIBLE HOSES Y11 Y11/423 VIBRATION ISOLATION - RUBBER BELLOWS Y11 Y11/431 DE-AERATORS, PRESSURE DIFFERENTIAL Y11 Y11/433 DE-AERATORS, TEMPERATURE DIFFERENTIAL Y11 Y11/437 CENTRIFUGAL AIR SEPARATORS Y11 Y11/439 COMBINED AIR AND DIRT SEPARATORS Y11 Y11/441 DIRT SEPARATORS Y11 Y11/451 GAUGES, PRESSURE AND ALTITUDE Y11 Y11/453 GAUGES, TEMPERATURE Y11 Y11/455 GAUGE MOUNTING BOARDS Y11 Y11/465 ACCESSORIES - BACKFLOW PREVENTION DEVICES Y11 Y11/466 HEAT METERS Y11 Y11/467 ACCESSORIES - PIPELINE STRAINERS Y11 Y11/469 ACCESSORIES - SAFETY VALVES Y11 Y11/471 ACCESSORIES - TEST POINTS Y11 Y11/473 ACCESSORIES - TUNDISHES Y11 Y11/475 ACCESSORIES - KEYS Y11 Y11/510 CONTRACTOR FABRICATED ANCILLARIES Y11 Y11/520 EXPANSION LOOPS, COPPER Y11 Y11/530 EXPANSION LOOPS, STEEL Y11 Y11/540 AIR BOTTLES Y11 Y11/610 INSTALLATION OF VALVES GENERALLY Y11 Y11/615 INSTALLATION OF VALVE STUFFING BOXES Y11 Y11/620 INSTALLATION OF DOUBLE REGULATING VALVES Y11 Y11/640 INSTALLATION OF FLOW MEASUREMENT DEVICES Y11 Y11/655 INSTALLATION OF THERMOSTATIC RADIATOR VALVES Y11 Y11/660 INSTALLATION OF VENT COCKS Y11 Y11/665 INSTALLATION OF DISCHARGE CONNECTIONS Y11 Y11/675 INSTALLATION OF EXPANSION COMPENSATORS Y11 Y11/677 INSTALLATION OF FLEXIBLE HOSES Y11 Y11/685 INSTALLATION OF COMBINED AIR AND DIRT SEPARATORS Y11 Y11/690 INSTALLATION OF EXPANSION LOOPS Y11 Y11/695 INSTALLATION OF CONTROL COMPONENTS Y11 Y11/700 VALVE TESTS Y11 Y12 MECHANICAL CLEANING AND CHEMICAL TREATMENT Y Y12/310 BIODISPERSANT CHEMICALS Y12 Y12/320 CORROSION INHIBITOR CHEMICALS Y12 Y12/330 DISPERSANT CHEMICALS Y12 Y12/340 NON-OXIDIZING BIOCIDES Y12 Y12/350 OXIDIZING BIOCIDES Y12 Y12/360 PH CONTROL CHEMICALS Y12 Y12/370 SCALE INHIBITOR CHEMICALS Y12 Y12/380 DOSING POTS Y12 Y12/610 GENERALLY Y12 Y12/620 FLUSHING OF HOT AND COLD WATER SYSTEMS Y12 Y12/630 FLUSHING OF HEATING AND CHILLED WATER SYSTEMS Y12 Y12/640 PURGING GAS PIPEWORK Y12 Y12/650 DISINFECTION OF HOT AND COLD WATER SYSTEMS Y12 Y12/660 CHEMICAL TREATMENT FOR HEATING SYSTEMS Y12 Y12/670 CHEMICAL TREATMENT FOR CHILLED WATER SYSTEMS Y12 Y12/680 CHEMICAL TREATMENT FOR EVAPORATIVE COOLING TOWER SYSTEMS Y12 Y12/690 INSTALLING DOSING POTS Y12 Y12/700 WATER QUALITY TESTS Y12 Y20 PUMPS Y Y20/310 PUMP SELECTION Y20 Y20/320 PUMPS GENERALLY Y20 Y20/330 CANNED ROTOR PUMPS Y20 Y20/340 CLOSE COUPLED END SUCTION PUMPS Y20 Y20/350 BELT DRIVEN END SUCTION PUMPS Y20 Y20/360 CLOSE COUPLED IN LINE PUMPS Y20 Y20/370 SUBMERSIBLE PUMPS Y20 Y20/380 FUEL OIL TRANSFER PUMPS Y20 Y20/400 SUCTION OR BOOSTER PUMPS Y20 Y20/410 PRESSURIZATION UNITS Y20 Y20/420 PRESSURE BOOSTER SETS Y20 Y20/610 INSTALLATION OF PUMPS GENERALLY Y20 Y20/630 INSTALLING PRESSURIZATION UNITS Y20 Y20/640 COMMISSIONING PREPARATION Y20 Y21 TANKS AND CISTERNS Y Y21/310 SECTIONAL STEEL TANK Y21 Y21/320 GLASS FIBRE REINFORCED TANKS AND CISTERNS Y21 Y21/325 GRAVITY TANKS Y21 Y21/330 PREFABRICATED GALVANIZED STEEL TANKS Y21 Y21/340 PREFABRICATED GALVANIZED STEEL CISTERNS Y21 Y21/350 MOULDED PLASTICS CISTERNS Y21 Y21/355 PRESSURE TANKS Y21 Y21/360 TANK CONTENTS GAUGES Y21 Y21/370 WARNING AND OVERFLOW PIPES TO FEED AND EXPANSION CISTERNS Y21 Y21/380 VENT PIPES Y21 Y21/610 INSTALLING TANKS AND CISTERNS Y21 Y21/620 INSTALLING FEED AND EXPANSION CISTERNS Y21 Y21/630 INSTALLING WARNING AND OVERFLOW PIPES TO FEED AND EXPANSION CISTERNS Y21 Y21/640 INSTALLATION OF VENT PIPES OVER FEED AND EXPANSION CISTERNS Y21 Y21/650 CLEANING Y21 Y22 HEATING EXCHANGERS Y Y22/310 STEAM NON-STORAGE CALORIFIERS Y22 Y22/320 HOT WATER NON-STORAGE CALORIFIERS Y22 Y22/350 PLATE HEAT EXCHANGERS Y22 Y22/610 INSTALLING HEAT EXCHANGERS Y22 Y24 TRACE HEATING SYSTEMS Y Y24/110 ELECTRICAL RESISTANCE TRACE HEATING SYSTEM Y24 Y24/210 ELECTRICAL RESISTANCE TRACE HEATING SYSTEM DESIGN Y24 Y24/220 SYSTEM PARAMETERS FOR PIPES Y24 Y24/230 SYSTEM PARAMETERS FOR VESSELS Y24 Y24/310 ELECTRICAL RESISTANCE SURFACE TRACE HEATING Y24 Y24/320 ELECTRICAL RESISTANCE SURFACE HEATING FOR HAZARDOUS ENVIRONMENTS Y24 Y24/350 CONTROL AND MONITORING Y24 Y24/610 STRIPPING OUT Y24 Y24/620 INSTALLING ELECTRICAL RESISTANCE SURFACE TRACE HEATING Y24 Y30 MECHANICAL THERMAL INSULATION Y Y30/110 INSULATION TO CONTROL HEAT LOSS FOR HOT WATER PIPELINES Y30 Y30/120 INSULATION TO CONTROL CONDENSATION FOR COLD WATER PIPELINES Y30 Y30/130 INSULATION TO CONTROL HEAT LOSS FOR LOW TEMPERATURE HOT WATER HEATING PIPELINES Y30 Y30/132 INSULATION TO CONTROL HEAT LOSS FOR MEDIUM TEMPERATURE HOT WATER HEATING PIPELINES Y30 Y30/135 INSULATION TO CONTROL HEAT LOSS FOR STEAM PIPELINES Y30 Y30/140 INSULATION TO CONTROL CONDENSATION FOR CHILLED WATER PIPELINES Y30 Y30/145 INSULATION TO CONTROL HEAT GAIN FOR CHILLED WATER PIPELINES Y30 Y30/150 INSULATION TO PROTECT AGAINST FREEZING FOR PIPELINES Y30 Y30/160 INSULATION FOR CONDENSATION CONTROL ON DUCTWORK CARRYING CHILLED AIR Y30 Y30/165 INSULATION TO CONTROL HEAT TRANSFER FOR CHILLED AND DUAL PURPOSE DUCTWORK Y30 Y30/170 INSULATION TO CONTROL HEAT LOSS FOR DUCTWORK CARRYING WARM AIR Y30 Y30/180 INSULATION TO CONTROL HEAT LOSS FOR LOW TEMPERATURE HOT WATER HEAT EXCHANGERS, CYLINDERS AND BUFFER VESSELS Y30 Y30/182 INSULATION TO CONTROL HEAT LOSS FOR MEDIUM TEMPERATURE HOT WATER HEAT EXCHANGERS, CYLINDERS AND BUFFER VESSELS Y30 Y30/185 INSULATION TO CONTROL CONDENSATION FOR WATER STORAGE TANKS Y30 Y30/190 INSULATION FOR BOILER FLUES Y30 Y30/310 CALCIUM SILICATE INSULATION PREFORMED SECTIONS AND SLABS Y30 Y30/320 METAL MESH FACED MINERAL FIBRE MATTRESSES Y30 Y30/330 MINERAL FIBRE PIPE SECTION INSULATION Y30 Y30/340 MINERAL FIBRE SLABS INSULATION Y30 Y30/350 NITRILE RUBBER INSULATION Y30 Y30/360 PHENOLIC FOAM INSULATION Y30 Y30/380 VAPOUR BARRIER PERMEANCE Y30 Y30/390 CANVAS PROTECTION Y30 Y30/395 FIBRE CLOTH PROTECTION Y30 Y30/405 POLYISOBUTYLENE PROTECTION Y30 Y30/415 PVC-U CASING PROTECTION Y30 Y30/420 SELF ADHESIVE CLADDING AND JACKETING Y30 Y30/425 SHEET ALUMINIUM CASING PROTECTION Y30 Y30/445 SHEET STEEL CASING PROTECTION Y30 Y30/480 INSULATION FOR VALVES AND FLANGES Y30 Y30/495 INSULATION AT LOADBEARING PIPELINE SUPPORTS Y30 Y30/610 INSTALLATION GENERALLY Y30 Y30/620 INSTALLATION OF CANVAS FACED MINERAL FIBRE INSULATION ON PIPELINES Y30 Y30/625 INSTALLATION OF FOIL FACED MINERAL FIBRE INSULATION ON PIPELINES Y30 Y30/630 INSTALLATION OF NITRILE RUBBER INSULATION ON PIPELINES Y30 Y30/640 INSTALLATION OF PHENOLIC FOAM INSULATION ON PIPELINES Y30 Y30/660 INSTALLATION OF FOIL FACED MINERAL FIBRE INSULATION ON DUCTWORK Y30 Y30/665 INSTALLATION OF FOIL FACED MINERAL FIBRE LAMELLA INSULATION ON DUCTWORK Y30 Y30/670 INSTALLATION OF INSULATION ON TANKS Y30 Y30/680 INSTALLATION OF MINERAL FIBRE LAMELLA INSULATION ON VESSELS Y30 Y30/690 INSTALLATION OF PHENOLIC FOAM INSULATION ON VESSELS Y30 Y30/700 INSTALLATION OF CANVAS PROTECTION Y30 Y30/710 INSTALLATION OF POLYISOBUTYLENE (PIB) PROTECTION Y30 Y30/715 INSTALLATION OF SELF ADHESIVE CLADDING AND JACKETING Y30 Y30/720 INSTALLATION OF SHEET ALUMINIUM PROTECTION Y30 Y30/730 INSTALLATION OF SHEET STEEL PROTECTION Y30 Y30/740 INSTALLATION AT VALVES AND FLANGES Y30 Y30/750 INSTALLATION AT LOADBEARING PIPELINES SUPPORTS Y30 Y30/755 INSTALLATION AT NON-LOADBEARING PIPELINES SUPPORTS Y30 Y30/760 INSULATION NOT CARRIED THROUGH PIPELINES SUPPORTS Y30 Y30/770 INSULATION CARRIED THROUGH DUCTWORK SUPPORTS Y30 Y30/800 INSTALLING VAPOUR BARRIERS Y30 Y31 VIBRATION ISOLATING MOUNTINGS AND SUPPORT SYSTEMS Y Y31/310 MOUNTINGS GENERALLY Y31 Y31/320 SPRING ISOLATORS Y31 Y31/330 COMPRESSION ISOLATORS Y31 Y31/340 ISOLATION HANGERS Y31 Y31/350 INERTIA BASES Y31 Y31/360 FLEXIBLE HOSES Y31 Y31/370 RUBBER BELLOWS Y31 Y31/380 MAT MOUNTINGS Y31 Y31/390 PAD MOUNTINGS Y31 Y31/400 ROOF SUPPORT SYSTEMS Y31 Y31/410 SERVICES SUPPORTS Y31 Y31/610 CAST IN SITU BASES Y31 Y31/910 DOCUMENTATION Y31 Y32 MECHANICAL PLANT AND EQUIPMENT IDENTIFICATION Y Y32/310 PLANT AND EQUIPMENT IDENTIFICATION LABELS Y32 Y32/320 VALVE IDENTIFICATION LABELS Y32 Y32/330 VALVE CHARTS AND SCHEMATICS Y32 Y32/610 IDENTIFYING PIPEWORK Y32 Y32/620 IDENTIFYING DUCTWORK Y32 Y32/630 INSTALLING PLANT AND EQUIPMENT IDENTIFICATION Y32 Y32/640 INSTALLING VALVE IDENTIFICATION Y32 Y32/650 INSTALLING VALVE CHARTS AND SCHEMATICS Y32 Y35 FLUES AND CHIMNEYS Y Y35/310 METAL FLUES AND CHIMNEYS Y35 Y35/320 LINERS Y35 Y35/340 SMOKE ALARMS Y35 Y35/610 INSTALLING FLUES AND CHIMNEYS Y35 Y35/810 TESTING FLUES AND CHIMNEYS Y35 Y35/820 ANALYSIS OF FLUE GASES Y35 Y40 MECHANICAL ENGINEERING SERVICES CONTROL AND MANAGEMENT SYSTEMS Y Y40/110 MECHANICAL ENGINEERING SERVICES SYSTEMS CENTRAL CONTROL AND MONITORING SYSTEM Y40 Y40/120 LOCAL WATER SUPPLY SYSTEMS CONTROLS Y40 Y40/130 LOCAL HEATING SYSTEMS CONTROLS Y40 Y40/140 LOCAL COOLING SYSTEMS CONTROLS Y40 Y40/150 LOCAL VENTILATION SYSTEMS CONTROLS Y40 Y40/160 LOCAL AIR CONDITIONING SYSTEMS CONTROLS Y40 Y40/170 ELECTRICAL CONNECTIONS Y40 Y40/175 ELECTRICAL CONNECTIONS BETWEEN CONTROL DEVICES AND PLANT AND EQUIPMENT Y40 Y40/210 DESIGN Y40 Y40/215 WATER SUPPLY SYSTEMS CONTROL STRATEGY Y40 Y40/217 STEAM AND CONDENSATE CONTROL STRATEGY Y40 Y40/220 HEATING SYSTEMS CONTROL STRATEGY Y40 Y40/222 GAS FIRED HEATING SYSTEM CONTROL STRATEGY Y40 Y40/223 RADIANT HEATING SYSTEM CONTROL STRATEGY Y40 Y40/225 COOLING SYSTEMS CONTROL STRATEGY Y40 Y40/228 CLIMATIC CEILING PANELS AND BEAMS CONTROL STRATEGY Y40 Y40/230 AIR TO AIR HEAT PUMP SYSTEM CONTROL STRATEGY Y40 Y40/232 WATER TO AIR HEAT PUMP SYSTEM CONTROL STRATEGY Y40 Y40/235 NATURAL VENTILATION CONTROL STRATEGY Y40 Y40/237 MIXED MODE VENTILATION SYSTEM CONTROL STRATEGY Y40 Y40/240 MECHANICAL VENTILATION SYSTEMS CONTROL STRATEGY Y40 Y40/242 MECHANICAL EXTRACT SYSTEMS CONTROL STRATEGY Y40 Y40/245 CONSTANT VOLUME AIR CONDITIONING SYSTEM CONTROL STRATEGY Y40 Y40/247 VARIABLE AIR VOLUME AIR CONDITIONING SYSTEM CONTROL STRATEGY Y40 Y40/250 FAN COIL UNIT AIR CONDITIONING SYSTEM CONTROL STRATEGY Y40 Y40/254 SMOKE AND HEAT CONTROL SYSTEM, PLANT SHUTDOWN CONTROL STRATEGY Y40 Y40/255 SMOKE AND HEAT CONTROL SYSTEM, EXTRACT POSITION CONTROL STRATEGY Y40 Y40/270 BOOST FIXED TIME Y40 Y40/272 DOMESTIC HOT WATER DEMAND Y40 Y40/274 FAN OVERRUN Y40 Y40/276 HAND OFF AUTO SWITCH Y40 Y40/278 LOW INSIDE AIR TEMPERATURE INTERLOCK FOR BUILDING FABRIC AND CONTENTS PROTECTION Y40 Y40/280 LOW TEMPERATURE INTERLOCK SIGNALS FOR PLANT PROTECTION Y40 Y40/282 NIGHT COOLING Y40 Y40/284 OPTIMUM START COOLING Y40 Y40/286 OPTIMUM STOP COOLING Y40 Y40/288 OPTIMUM START HEATING Y40 Y40/290 OPTIMUM STOP HEATING Y40 Y40/292 PUMP OVERRUN Y40 Y40/294 TIME CONTROL Y40 Y40/302 CHP CONTROL STRATEGY Y40 Y40/304 MODULAR BOILERS CONTROL STRATEGY Y40 Y40/306 LOW CONTENT BOILERS SEQUENCING CONTROL STRATEGY Y40 Y40/308 BOILERS, WITH INDIVIDUAL ISOLATING VALVES, SEQUENCING CONTROL STRATEGY Y40 Y40/310 SEQUENCING BOILERS, WITH INDIVIDUAL PUMP AND BYPASS CIRCUIT, CONTROL STRATEGY Y40 Y40/312 SEQUENCING NON-IDENTICAL GROUPS OF BOILERS, WITH INDIVIDUAL PUMP AND BYPASS CIRCUIT, CONTROL STRATEGY Y40 Y40/314 SINGLE BOILER CONTROL STRATEGY Y40 Y40/316 GAS PRESSURIZATION UNIT CONTROL STRATEGY Y40 Y40/317 PUMP PRESSURIZATION UNIT CONTROL STRATEGY Y40 Y40/318 SEALED EXPANSION VESSEL PRESSURIZATION UNIT CONTROL STRATEGY Y40 Y40/319 STATIC HEAD PRESSURIZATION CONTROL STRATEGY Y40 Y40/322 HEATING SECONDARY CIRCUITS CONTROL STRATEGY Y40 Y40/324 DOMESTIC HOT WATER NON-STORAGE CALORIFIER CONTROL STRATEGY Y40 Y40/325 HEATING NON-STORAGE CALORIFIER CONTROL STRATEGY Y40 Y40/326 STORAGE CALORIFIER CONTROL STRATEGY Y40 Y40/328 CONSTANT SPEED PUMPS CONTROL STRATEGY Y40 Y40/329 VARIABLE SPEED PUMPS CONTROL STRATEGY Y40 Y40/330 MULTIPLE SPEED PUMPS CONTROL STRATEGY Y40 Y40/332 PACKAGED AIR COOLED WATER CHILLER CONTROL STRATEGY Y40 Y40/334 PACKAGED AIR COOLED WATER CHILLER, WITH HEAT RECLAIM, CONTROL STRATEGY Y40 Y40/336 WATER COOLED WATER CHILLER CONTROL STRATEGY Y40 Y40/338 OPEN CIRCUIT COOLING TOWER CONTROL STRATEGY Y40 Y40/339 CLOSED CIRCUIT COOLING TOWER CONTROL STRATEGY Y40 Y40/345 FULL OUTSIDE AIR DAMPER CONTROL STRATEGY Y40 Y40/346 MIXING DAMPER CONTROL STRATEGY Y40 Y40/347 CARBON DIOXIDE DEMAND DAMPER OVERRIDE CONTROL STRATEGY Y40 Y40/350 ELECTRIC HEATER BATTERY, PRE-HEAT COIL AND FROST PROTECTION CONTROL STRATEGY Y40 Y40/351 LOW TEMPERATURE HOT WATER PRE-HEAT COIL AND FROST PROTECTION STRATEGY Y40 Y40/352 ELECTRIC HEATER BATTERY CONTROL STRATEGY Y40 Y40/353 LOW TEMPERATURE HOT WATER HEATING COIL CONTROL STRATEGY Y40 Y40/354 FIXED PLATE HEAT EXCHANGER CONTROL STRATEGY Y40 Y40/355 RUN AROUND COIL CONTROL STRATEGY Y40 Y40/356 THERMAL WHEEL, FIXED SPEED WITH BYPASS DAMPER, CONTROL STRATEGY Y40 Y40/357 THERMAL WHEEL, VARIABLE SPEED, CONTROL STRATEGY Y40 Y40/359 CHILLED WATER COOLING COIL CONTROL STRATEGY Y40 Y40/360 DIRECT EXPANSION (DX) COOLING COIL CONTROL STRATEGY Y40 Y40/361 CHILLED WATER DEHUMIDIFICATION COIL, WITH FACE AND BYPASS DAMPERS, CONTROL STRATEGY Y40 Y40/362 CHILLED WATER DEHUMIDIFICATION COIL CONTROL STRATEGY Y40 Y40/363 DIRECT EXPANSION (DX) DEHUMIDIFICATION COIL, WITH FACE AND BYPASS DAMPERS, CONTROL STRATEGY Y40 Y40/364 DIRECT EXPANSION (DX) DEHUMIDIFICATION COIL CONTROL STRATEGY Y40 Y40/366 CONSTANT VOLUME SUPPLY FAN CONTROL STRATEGY Y40 Y40/367 TWO SPEED SUPPLY FAN CONTROL STRATEGY Y40 Y40/368 VAV BRANCH DUCT, SUPPLY FAN SPEED CONTROL STRATEGY Y40 Y40/369 VAV MAIN DUCT, SUPPLY FAN SPEED CONTROL STRATEGY Y40 Y40/370 VAV SYSTEM, SUPPLY FAN SPEED CONTROL STRATEGY Y40 Y40/372 ATOMIZED SPRAY HUMIDIFIER CONTROL STRATEGY Y40 Y40/373 STEAM HUMIDIFIER CONTROL STRATEGY Y40 Y40/375 CONSTANT VOLUME EXTRACT FAN CONTROL STRATEGY Y40 Y40/376 TWO SPEED EXTRACT FAN CONTROL STRATEGY Y40 Y40/377 VARIABLE VOLUME EXTRACT FAN CONTROL STRATEGY Y40 Y40/380 CONSTANT VOLUME AIR TERMINAL UNIT, WITH REHEAT, CONTROL STRATEGY Y40 Y40/381 INDUCTION VAV AIR TERMINAL UNIT CONTROL STRATEGY Y40 Y40/382 PRESSURE DEPENDENT, FAN ASSISTED, VAV TERMINAL UNIT, WITH REHEAT, CONTROL STRATEGY Y40 Y40/383 PRESSURE DEPENDENT, VAV TERMINAL UNIT, WITH REHEAT, CONTROL STRATEGY Y40 Y40/384 PRESSURE INDEPENDENT, INTELLIGENT VAV TERMINAL UNIT, WITH REHEAT, CONTROL STRATEGY Y40 Y40/385 PRESSURE INDEPENDENT, VAV TERMINAL UNIT, WITH REHEAT, CONTROL STRATEGY Y40 Y40/387 FAN COIL UNIT, AIR SIDE CONTROL STRATEGY Y40 Y40/388 FAN COIL UNIT, WATER SIDE CONTROL STRATEGY Y40 Y40/390 AIR FILTER WITH PRESSURE SENSOR CONTROL STRATEGY Y40 Y40/392 CONSTANT AIR VOLUME SYSTEM, ZONE TEMPERATURE CONTROL OF PRIMARY SUPPLY AIR TEMPERATURE CONTROL STRATEGY Y40 Y40/393 SUPPLY AIR TEMPERATURE SET POINT, SCHEDULED TO OUTSIDE AIR TEMPERATURE CONTROL STRATEGY Y40 Y40/394 VAV SUPPLY AIR TEMPERATURE SET POINT, RESET WITH INTELLIGENT TERMINAL UNITS CONTROL STRATEGY Y40 Y40/395 VAV SUPPLY AIR TEMPERATURE SCHEDULED TO FAN SPEED CONTROL STRATEGY Y40 Y40/396 ZONE AIR TEMPERATURE CONTROL Y40 Y40/410 ACTUATOR DATA LOGGING Y40 Y40/415 ALARM DATA LOGGING Y40 Y40/420 MOTORIZED VALVE DATA LOGGING Y40 Y40/425 SENSOR DATA LOGGING Y40 Y40/430 THERMOSTAT DATA LOGGING Y40 Y40/435 COOLING PLANT MONITORING Y40 Y40/440 FAN MONITORING Y40 Y40/445 HEATING PLANT MONITORING Y40 Y40/450 HUMIDIFIER MONITORING Y40 Y40/455 PRESSURIZATION UNIT MONITORING Y40 Y40/460 PUMP MONITORING Y40 Y40/465 WATER TREATMENT PLANT MONITORING Y40 Y40/510 CONTROL PANEL Y40 Y40/515 LOW VOLTAGE FUSES Y40 Y40/516 MINIATURE CIRCUIT BREAKERS Y40 Y40/520 ANALOGUE METERING EQUIPMENT IN CONTROL PANEL Y40 Y40/521 DIGITAL MULTI-FUNCTION METERING EQUIPMENT IN CONTROL PANEL Y40 Y40/525 INDICATOR LAMPS Y40 Y40/530 PADLOCKS AND KEYS Y40 Y40/531 PADLOCK AND KEY CABINETS Y40 Y40/535 SAFETY MATTING Y40 Y40/540 ACTUATORS Y40 Y40/545 ALARMS Y40 Y40/550 MOTORIZED VALVES Y40 Y40/555 RADIO BASED EQUIPMENT Y40 Y40/560 SENSORS, AIR QUALITY Y40 Y40/565 SENSORS, FLOW IN DUCT Y40 Y40/566 SENSORS, FLOW IN PIPE Y40 Y40/570 SENSORS, HUMIDITY Y40 Y40/575 SENSORS, PRESSURE Y40 Y40/580 SENSORS, AIR TEMPERATURE Y40 Y40/585 SENSORS, WATER TEMPERATURE Y40 Y40/590 BALANCED TWISTED-PAIR CABLES Y40 Y40/610 STRIPPING OUT Y40 Y40/620 INSTALLATION OF SENSORS GENERALLY Y40 Y40/630 LOCATION OF ACTUATORS Y40 Y40/640 LOCATION OF MOTORIZED VALVES Y40 Y40/650 LOCATION OF SENSORS, AIR QUALITY Y40 Y40/660 LOCATION OF SENSORS, FLOW Y40 Y40/670 LOCATION OF SENSORS, HUMIDITY Y40 Y40/680 LOCATION OF SENSORS, PRESSURE Y40 Y40/690 LOCATION OF SENSORS, TEMPERATURE Y40 Y40/700 INSTALLING CONTROL PANELS Y40 Y40/710 CABLE INSTALLATION GENERALLY Y40 Y40/810 INSPECTION AND TESTING Y40 Y40/815 START UP AND COMMISSIONING Y40 Y40/820 SPARES Y40 Y40/830 KEYS Y40 Y40/840 DOCUMENTATION Y40 Y40/850 MAINTENANCE Y40 Y41 BUILDING MONITORING AND MANAGEMENT SYSTEMS Y Y41/110 ELECTRICITY METERING Y41 Y41/120 FUEL METERING Y41 Y41/130 WATER METERING Y41 Y41/150 BUILDING MONITORING AND MANAGEMENT SYSTEM Y41 Y41/160 ELECTRICAL CONNECTIONS Y41 Y41/210 DESIGN Y41 Y41/215 METER DATA Y41 Y41/217 WATER SUPPLY SYSTEMS MONITORING AND MANAGEMENT Y41 Y41/220 MEDICAL GAS SYSTEMS MONITORING AND MANAGEMENT Y41 Y41/225 GAS SUPPLY SYSTEMS MONITORING AND MANAGEMENT Y41 Y41/227 LIQUID FUEL SUPPLY SYSTEMS MONITORING AND MANAGEMENT Y41 Y41/230 STEAM AND CONDENSATE SYSTEM MONITORING AND MANAGEMENT Y41 Y41/235 FIRE FIGHTING SYSTEMS MONITORING AND MANAGEMENT Y41 Y41/240 HEATING SYSTEMS MONITORING AND MANAGEMENT Y41 Y41/243 COOLING WATER SYSTEMS MONITORING AND MANAGEMENT Y41 Y41/247 VENTILATION SYSTEMS MONITORING AND MANAGEMENT Y41 Y41/250 AIR CONDITIONING SYSTEMS MONITORING AND MANAGEMENT Y41 Y41/255 HIGH VOLTAGE SUPPLY MONITORING AND MANAGEMENT Y41 Y41/257 LOW VOLTAGE SUPPLY MONITORING AND MANAGEMENT Y41 Y41/260 LIGHTING SYSTEMS MONITORING AND MANAGEMENT Y41 Y41/263 EMERGENCY LIGHTING SYSTEMS MONITORING AND MANAGEMENT Y41 Y41/265 COMMUNICATIONS SYSTEMS MONITORING AND MANAGEMENT Y41 Y41/267 TELEVISION AND DATA SYSTEMS MONITORING AND MANAGEMENT Y41 Y41/270 SECURITY SYSTEMS MONITORING AND MANAGEMENT Y41 Y41/273 DETECTION AND ALARM SYSTEMS MONITORING AND MANAGEMENT Y41 Y41/277 PROTECTION SYSTEMS MONITORING AND MANAGEMENT Y41 Y41/280 DISPLAY AND INFORMATION SYSTEMS MONITORING AND MANAGEMENT Y41 Y41/285 TRANSPORT SYSTEMS MONITORING AND MANAGEMENT Y41 Y41/310 ENCLOSURE Y41 Y41/440 FIELD CONTROLLERS Y41 Y41/445 DESKTOP PC Y41 Y41/450 KEYBOARDS Y41 Y41/460 MONITORS Y41 Y41/510 PRINTERS Y41 Y41/540 RADIO BASED EQUIPMENT Y41 Y41/550 BALANCED TWISTED-PAIR CABLES Y41 Y41/610 STRIPPING OUT Y41 Y41/620 INSTALLATION OF BUILDING MONITORING AND MANAGEMENT SYSTEMS Y41 Y41/625 INSTALLATION OF FIELD CONTROLLERS Y41 Y41/627 INSTALLATION OF CABLES Y41 Y41/630 INSTALLATION OF SENSORS Y41 Y41/810 INSPECTION AND TESTING Y41 Y41/815 COMMISSIONING Y41 Y41/820 SPARES Y41 Y41/825 KEYS Y41 Y41/830 DOCUMENTATION Y41 Y50 MECHANICAL COMMISSIONING Y Y50/610 COMMISSIONING PROGRAMME Y50 Y50/620 COMMISSIONING OF HOT AND COLD WATER SUPPLY SYSTEMS Y50 Y50/630 COMMISSIONING OF WATER HEATING SYSTEMS Y50 Y50/640 COMMISSIONING SOLAR HEATING SYSTEMS Y50 Y50/650 COMMISSIONING OF BOILER PLANT Y50 Y50/660 COMMISSIONING OF CHILLED WATER SYSTEMS Y50 Y50/670 COMMISSIONING OF REFRIGERATING SYSTEMS Y50 Y50/680 COMMISSIONING OF AIR DISTRIBUTION SYSTEMS Y50 Y50/690 COMMISSIONING OF CENTRAL CONTROLS AND BUILDING MANAGEMENT SYSTEMS Y50 Y50/700 PERFORMANCE TESTING PROGRAMME Y50 Y50/710 PERFORMANCE TESTING Y50 Y50/750 INSPECTION AND TEST RECORDS Y50 Y50/760 DEMONSTRATIONS Y50 Y60 CONDUIT, TRUNKING AND DUCTING Y Y60/310 CONDUIT, TRUNKING AND DUCTING GENERALLY Y60 Y60/320 RIGID CONDUIT Y60 Y60/330 PLIABLE CONDUIT Y60 Y60/340 FLEXIBLE CONDUIT Y60 Y60/350 BURIED CONDUIT Y60 Y60/370 SLOTTED CABLE TRUNKING Y60 Y60/380 CABLE TRUNKING AND CABLE DUCTING SYSTEMS Y60 Y60/390 FLOOR CABLE TRUNKING AND CABLE DUCTING SYSTEMS Y60 Y60/420 SERVICE OUTLETS Y60 Y60/430 RAISED ACCESS FLOOR SERVICE OUTLETS Y60 Y60/440 SERVICE OUTLET POLES Y60 Y60/450 PROPRIETARY TRUNKING Y60 Y60/460 CONDUIT FITTINGS Y60 Y60/475 INTUMESCENT LINEAR GAP SEALS Y60 Y60/610 INSTALLING CONDUIT, TRUNKING AND DUCTING Y60 Y60/620 PROTECTION OF METALLIC CONDUIT, TRUNKING AND DUCTING Y60 Y60/630 INSTALLING CONDUIT GENERALLY Y60 Y60/640 INSTALLING RIGID METALLIC CONDUIT Y60 Y60/650 INSTALLING RIGID NON METALLIC CONDUIT Y60 Y60/660 INSTALLING PLIABLE AND FLEXIBLE CONDUIT Y60 Y60/670 INSTALLING CONDUIT IN CONCRETE Y60 Y60/680 INSTALLING CONDUIT CONNECTIONS TO EQUIPMENT Y60 Y60/690 INSTALLING TRUNKING GENERALLY Y60 Y60/710 INSTALLING UNDERFLOOR DUCTING Y60 Y60/715 INSTALLING FLUSH FLOOR TRUNKING Y60 Y60/720 DRAINAGE OF CONDUIT, TRUNKING AND DUCTING Y60 Y60/730 SPARE CONDUIT, TRUNKING AND DUCTING Y60 Y60/740 CONDUIT, TRUNKING AND DUCTING ZONES Y60 Y60/750 INSTALLING SERVICE OUTLETS GENERALLY Y60 Y60/760 INSTALLING RAISED ACCESS FLOOR SERVICE OUTLETS Y60 Y60/770 SUPPORTS AND FIXINGS Y60 Y60/780 CLEANING Y60 Y63 CABLE SUPPORTS Y Y63/310 SELECTION OF CABLE SUPPORTS Y63 Y63/320 CABLE BASKETS Y63 Y63/330 CABLE LADDERS Y63 Y63/340 CABLE TRAYS Y63 Y63/370 CABLE SUPPORT BRACKETS Y63 Y63/385 CABLE CLEATS Y63 Y63/390 CABLE TIES Y63 Y63/395 CABLE BANDS Y63 Y63/610 INSTALLING CABLE SUPPORTS Y63 Y63/620 MULTIPLE CABLE RUNS Y63 Y63/630 INSTALLING CABLE TRAY AND CABLE LADDER Y63 Y63/640 INSTALLING CABLE BASKET Y63 Y63/650 INSTALLING PROTECTIVE COVERS Y63 Y63/660 CABLE INSTALLATION Y63 Y63/670 INSTALLING CABLE SUPPORTS ON ROOFS Y63 Y63/680 INSTALLING BRACKETS FOR CABLE SUPPORTS Y63 Y63/690 CABLE SUPPORT ZONES Y63 Y63/810 INSPECTION AND TESTING Y63 Y65 ELECTRICAL ACCESSORIES Y Y65/310 PRODUCTS GENERALLY Y65 Y65/320 ELECTRICAL ACCESSORIES Y65 Y65/330 SURFACE AND CONCEALED WIRING ENCLOSURES Y65 Y65/340 LIGHT SWITCHES Y65 Y65/350 DIMMER SWITCHES AND CONTROLS Y65 Y65/360 FUSED CONNECTION UNITS Y65 Y65/370 CABLE OUTLETS Y65 Y65/380 STANDARD SOCKET OUTLETS Y65 Y65/385 SPECIALIST SOCKET OUTLETS Y65 Y65/400 INDUSTRIAL SOCKET OUTLETS Y65 Y65/405 INDUSTRIAL PLUGS Y65 Y65/410 CABLE COUPLERS Y65 Y65/420 FAN ISOLATORS Y65 Y65/430 ROUND PIN SOCKET OUTLETS Y65 Y65/440 SINGLE VOLTAGE SHAVER OUTLETS Y65 Y65/450 SHAVER SUPPLY UNITS Y65 Y65/460 DOUBLE POLE SWITCHES Y65 Y65/470 COOKER CONTROL UNITS Y65 Y65/480 COOKER CONNECTION UNITS Y65 Y65/485 CEILING POWER SWITCHES Y65 Y65/490 CEILING LIGHT SWITCHES Y65 Y65/610 INSTALLING ELECTRICAL ACCESSORIES Y65 Y65/620 ARRANGEMENT Y65 Y65/630 GRID SWITCH PLATES Y65 Y65/640 INSTALLING LIGHT SWITCHES Y65 Y67 TRANSIENT OVERVOLTAGE SURGE SUPPRESSION DEVICES Y Y67/310 TRANSIENT OVERVOLTAGE SURGE SUPPRESSION DEVICES FOR MAINS POWER SUPPLIES Y67 Y67/320 TRANSIENT OVERVOLTAGE SURGE SUPPRESSION FOR PLUG IN MAINS POWER SUPPLIES Y67 Y67/330 TRANSIENT OVERVOLTAGE SURGE SUPPRESSION FOR DATA AND TELECOM SUPPLIES Y67 Y67/340 ENCLOSURES. Y67 Y67/620 INSTALLATION GENERALLY Y67 Y67/630 INSTALLING TRANSIENT OVERVOLTAGE SURGE SUPPRESSION DEVICES FOR MAINS POWER SUPPLIES AND DATA AND TELECOM SUPPLIES Y67 Y67/640 INSTALLING TRANSIENT OVERVOLTAGE SURGE SUPPRESSION FOR PLUG IN MAINS POWER SUPPLIES Y67 Y67/650 LABELLING Y67 Z BUILDING FABRIC REFERENCE SPEC Z10 PURPOSE MADE JOINERY Z Z10/110 FABRICATION Z10 Z10/120 CROSS SECTION DIMENSIONS OF TIMBER Z10 Z10/130 PRESERVATIVE TREATED WOOD Z10 Z10/140 MOISTURE CONTENT Z10 Z10/210 LAMINATED PLASTICS VENEERED BOARDS/ PANELS Z10 Z10/220 WOOD VENEERED BOARDS/ PANELS Z10 Z10/250 FINISHING Z10 Z11 PURPOSE MADE METALWORK Z Z11/310 MATERIALS GENERALLY Z11 Z11/320 STEEL LONG AND FLAT PRODUCTS Z11 Z11/330 STEEL PLATE, SHEET AND STRIP Z11 Z11/340 HOT ROLLED STEEL PLATE, SHEET AND STRIP Z11 Z11/350 COLD ROLLED STEEL PLATE, SHEET AND STRIP Z11 Z11/360 COATED STEEL FLAT PRODUCTS Z11 Z11/370 STEEL STRUCTURAL HOLLOW SECTIONS (SHS) Z11 Z11/380 OTHER STEEL SECTIONS Z11 Z11/400 STAINLESS STEEL PRODUCTS Z11 Z11/410 ALUMINIUM ALLOY PRODUCTS Z11 Z11/420 COPPER ALLOY PRODUCTS Z11 Z11/515 FABRICATION GENERALLY Z11 Z11/520 COLD FORMED WORK Z11 Z11/525 ADHESIVE BONDING Z11 Z11/527 WELDING Z11 Z11/530 STAINLESS STEEL FABRICATION Z11 Z11/555 BRAZING Z11 Z11/610 TESTING Z11 Z11/710 FINISHING WELDED AND BRAZED JOINTS VISIBLE IN COMPLETE WORK Z11 Z11/745 PREPARATION FOR APPLICATION OF COATINGS Z11 Z11/750 LIQUID ORGANIC COATING FOR ALUMINIUM ALLOY COMPONENTS Z11 Z11/760 ZINC AND CADMIUM PLATING OF IRON AND STEEL SURFACES Z11 Z11/770 CHROMIUM PLATING Z11 Z11/780 GALVANIZING Z11 Z11/790 VITREOUS ENAMELLING Z11 Z11/910 DOCUMENTATION Z11 Z11/920 COMPLETION Z11 Z12 PRESERVATIVE/ FIRE RETARDANT TREATMENT Z Z12/110 TREATMENT APPLICATION Z12 Z12/120 COMMODITY SPECIFICATIONS Z12 Z12/130 PRESERVATIVE TREATMENT SOLUTION STRENGTHS/ TREATMENT CYCLES Z12 Z12/140 COPPER-ORGANIC PRESERVATIVE TREATMENT Z12 Z12/160 ORGANIC SOLVENT PRESERVATIVE TREATMENT Z12 Z12/165 WATER-BASED MICROEMULSION PRESERVATIVE TREATMENT Z12 Z12/167 BORON COMPOUND PRESERVATIVE TREATMENT Z12 Z12/180 RECYCLED TIMBER CONTAINING CREOSOTE OR CHROMIUM/ ARSENIC BASED PRESERVATIVE Z12 Z12/210 FIRE RETARDANT TREATMENT Z12 Z12/220 LEACH RESISTANT FIRE RETARDANT TREATMENT Z12 Z12/610 MAKING GOOD TO PRESERVATIVE TREATMENT ON-SITE Z12 Z12/620 MAKING GOOD TO FIRE RETARDANT TREATMENT ON-SITE Z12 Z20 FIXINGS AND ADHESIVES Z Z20/310 FASTENERS GENERALLY Z20 Z20/320 PACKINGS Z20 Z20/330 NAILED TIMBER FASTENERS Z20 Z20/340 MASONRY FIXINGS Z20 Z20/350 PLUGS Z20 Z20/360 ANCHORS Z20 Z20/370 WOOD SCREWS Z20 Z20/380 MISCELLANEOUS SCREWS Z20 Z20/390 ADHESIVES Z20 Z20/410 POWDER ACTUATED FIXING SYSTEMS Z20 Z20/610 FIXING GENERALLY Z20 Z20/620 FIXING THROUGH FINISHES Z20 Z20/630 FIXING PACKINGS Z20 Z20/640 FIXING CRAMPS Z20 Z20/650 NAILED TIMBER FIXING Z20 Z20/660 SCREW FIXING Z20 Z20/670 PELLETED COUNTERSUNK SCREW FIXING Z20 Z20/680 PLUGGED COUNTERSUNK SCREW FIXING Z20 Z20/690 USING POWDER ACTUATED FIXING SYSTEMS Z20 Z20/700 APPLYING ADHESIVES Z20 Z21 MORTARS Z Z21/110 CEMENT GAUGED MORTAR MIXES Z21 Z21/120 SAND FOR SITE MADE CEMENT GAUGED MASONRY MORTARS Z21 Z21/131 READY-MIXED LIME:SAND FOR CEMENT GAUGED MASONRY MORTARS Z21 Z21/135 SITE MADE LIME:SAND FOR CEMENT GAUGED MASONRY MORTARS Z21 Z21/160 CEMENTS FOR MORTARS Z21 Z21/180 ADMIXTURES FOR SITE MADE CEMENT GAUGED MORTARS Z21 Z21/190 RETARDED READY TO USE CEMENT GAUGED MORTAR Z21 Z21/200 STORAGE OF CEMENT GAUGED MORTAR MATERIALS Z21 Z21/210 MAKING CEMENT GAUGED MORTARS Z21 Z21/310 LIME:SAND MORTAR MIXES Z21 Z21/320 SAND FOR LIME:SAND MASONRY MORTARS Z21 Z21/330 READY PREPARED LIME PUTTY Z21 Z21/335 READY PREPARED LIME PUTTY Z21 Z21/340 POZZOLANIC ADDITIVES FOR NONHYDRAULIC LIME:SAND MORTARS Z21 Z21/345 ADMIXTURES FOR HYDRAULIC LIME:SAND MORTARS Z21 Z21/350 STORAGE OF LIME:SAND MORTAR MATERIALS Z21 Z21/360 MAKING LIME:SAND MORTARS GENERALLY Z21 Z21/370 SITE PREPARED NONHYDRAULIC LIME:SAND MORTARS Z21 Z21/380 READY TO USE NONHYDRAULIC LIME:SAND MORTARS Z21 Z21/390 KNOCKING UP NONHYDRAULIC LIME:SAND MORTARS Z21 Z21/400 MAKING HYDRAULIC LIME:SAND MORTARS Z21 Z22 SEALANTS Z Z22/310 JOINTS Z22 Z22/610 SUITABILITY OF JOINTS Z22 Z22/620 PREPARING JOINTS Z22 Z22/630 APPLYING SEALANTS Z22 Z31 POWDER COATINGS Z Z31/120 POWDER COATING MATERIALS Z31 Z31/210 WORKING PROCEDURES Z31 Z31/220 POWDER COATING APPLICATORS Z31 Z31/225 GUARANTEES Z31 Z31/230 CONTROL SAMPLES Z31 Z31/235 INDEPENDENT INSPECTION AT PLANT Z31 Z31/240 QUALITY ASSURANCE SYSTEM Z31 Z31/250 COMPONENT DESIGN Z31 Z31/310 PRETREATMENT OF ALUMINIUM COMPONENTS Z31 Z31/320 PRETREATMENT OF STEEL COMPONENTS Z31 Z31/430 EXTENT OF POWDER COATINGS Z31 Z31/435 APPLICATION OF POWDER COATINGS Z31 Z31/440 PERFORMANCE AND APPEARANCE OF POWDER COATINGS Z31 Z31/450 ALUMINIUM ALLOY FABRICATIONS Z31 Z31/460 STEEL FABRICATIONS Z31 Z31/470 FIXINGS Z31 Z31/480 DAMAGED COMPONENTS - REPAIR/ REPLACEMENT Z31 Z31/510 PROTECTION Z31 Z31/535 DOCUMENTATION Z31 Z31/540 COMPLETION Z31 Z33 ANODIZING Z Z33/110 ANODIC COATING Z33 Z33/210 WORKING PROCEDURES Z33 Z33/220 ANODIZER REQUIREMENTS Z33 Z33/230 GUARANTEES Z33 Z33/240 CONTROL SAMPLES Z33 Z33/250 INDEPENDENT INSPECTION AT PLANT Z33 Z33/255 QUALITY ASSURANCE SYSTEM Z33 Z33/270 COMPONENT DESIGN Z33 Z33/310 PRETREATMENT Z33 Z33/410 EXTENT OF ANODIC COATINGS Z33 Z33/420 APPLICATION OF ANODIC COATINGS Z33 Z33/430 PERFORMANCE AND APPEARANCE OF ANODIC COATINGS Z33 Z33/440 FABRICATION Z33 Z33/450 DAMAGED COMPONENTS - REPAIR/ REPLACEMENT Z33 Z33/510 PROTECTION Z33 Z33/530 DOCUMENTATION Z33 Z33/540 COMPLETION Z33