Question

Compare the efficiency of workers A, B, C and D using the given block x machine layout.

# Data transcribed from the image exactly as shown
# (Block I has A twice and no D in the provided table)
df <- data.frame(
  Block = factor(rep(c("I", "II", "III", "IV", "V", "VI"), each = 4)),
  Machine = factor(rep(c("M1", "M2", "M3", "M4"), times = 6)),
  Worker = factor(c(
    "C", "A", "B", "A",
    "A", "B", "C", "D",
    "A", "C", "D", "B",
    "A", "D", "C", "B",
    "B", "C", "A", "D",
    "D", "C", "A", "B"
  )),
  Yield = c(
    22, 14, 12, 23,
    16, 18, 20, 25,
    15, 23, 28, 14,
    17, 21, 19, 11,
    18, 20, 13, 24,
    18, 21, 10, 17
  )
)

df
##    Block Machine Worker Yield
## 1      I      M1      C    22
## 2      I      M2      A    14
## 3      I      M3      B    12
## 4      I      M4      A    23
## 5     II      M1      A    16
## 6     II      M2      B    18
## 7     II      M3      C    20
## 8     II      M4      D    25
## 9    III      M1      A    15
## 10   III      M2      C    23
## 11   III      M3      D    28
## 12   III      M4      B    14
## 13    IV      M1      A    17
## 14    IV      M2      D    21
## 15    IV      M3      C    19
## 16    IV      M4      B    11
## 17     V      M1      B    18
## 18     V      M2      C    20
## 19     V      M3      A    13
## 20     V      M4      D    24
## 21    VI      M1      D    18
## 22    VI      M2      C    21
## 23    VI      M3      A    10
## 24    VI      M4      B    17
table(df$Block, df$Worker)
##      
##       A B C D
##   I   2 1 1 0
##   II  1 1 1 1
##   III 1 1 1 1
##   IV  1 1 1 1
##   V   1 1 1 1
##   VI  1 1 1 1
aggregate(Yield ~ Worker, data = df, FUN = mean)
##   Worker    Yield
## 1      A 15.42857
## 2      B 15.00000
## 3      C 20.83333
## 4      D 23.20000

Analysis

# Compare reduced and full models to isolate worker effect
reduced <- lm(Yield ~ Block + Machine, data = df)
full <- lm(Yield ~ Block + Machine + Worker, data = df)
comparison <- anova(reduced, full)
comparison
## Analysis of Variance Table
## 
## Model 1: Yield ~ Block + Machine
## Model 2: Yield ~ Block + Machine + Worker
##   Res.Df    RSS Df Sum of Sq      F   Pr(>F)   
## 1     15 431.13                                
## 2     12 145.64  3    285.48 7.8406 0.003672 **
## ---
## Signif. codes:  0 '***' 0.001 '**' 0.01 '*' 0.05 '.' 0.1 ' ' 1
p_worker <- comparison[2, "Pr(>F)"]

if (p_worker < alpha) {
  cat("Decision: Reject H0 at 5% significance level.\n")
  cat("Conclusion: Worker efficiency differs significantly after adjusting for block and machine effects.")
} else {
  cat("Decision: Fail to reject H0 at 5% significance level.\n")
  cat("Conclusion: No significant worker-efficiency difference is detected after adjustment.")
}
## Decision: Reject H0 at 5% significance level.
## Conclusion: Worker efficiency differs significantly after adjusting for block and machine effects.