1987 DESIGN OF EXPERIMENT ESSEX TAPE DATA PLANT --ESSEX ENGINE CASTING PLANT COMPONENT--3.8 LITER ENGINE PROBLEM --PISTON DOME POROSITY 2**(7-4) FRACTIONAL FACTORIAL DESIGN (L8) NUMBER OF OBSERVATIONS = 8 NUMBER OF FACTORS = 7 TOTAL NUMBER OF VARIABLES PER LINE IMAGE = 8 RESPONSE VARIABLE = % DEFECTIVE PISTONS IN A BATCH OF 700 FACTOR 1 = MOLD TEMPERATURE (2 LEVELS--412 & 525) FACTOR 2 = DOWNSPRUE RISER (2 LEVELS--STANDARD & SMALLER) FACTOR 3 = METAL TEMPERTURE (2 LEVELS--1240 & 1190) FACTOR 4 = MOLD COATING METHOD (2 LEVELS--FULL & PARTIAL) FACTOR 5 = RISER DESIGN (2 LEVELS--SINGLE & DOUBLE) FACTOR 6 = MOLD DESIGN (2 LEVELS--POCKET & NO-POCKET) FACTOR 7 = MACHINE CYCLE (2 LEVELS--STANDARD & SHORT) TO READ THIS INTO DATAPLOT-- DIMENSION 20 VARIABLES SKIP 25 READ ESSEX.DAT Y X1 TO X7 Y X1 X2 X3 X4 X5 X6 X7 ---------------------------- 0.00 1 1 1 1 1 1 1 0.00 1 1 1 2 2 2 2 0.51 1 2 2 1 1 2 2 0.97 1 2 2 2 2 1 1 0.00 2 1 2 1 2 1 2 0.00 2 1 2 2 1 2 1 0.00 2 2 1 1 2 2 1 3.17 2 2 1 2 1 1 2