This is Dataplot data file NELSNIST.DAT Electromigration failure times in aluminum conductor microcircuits Wayne Nelson & Necip Doganaksoy: NIST Report (1992) Accelerated test specs--59 aluminum conductors each conductor had length 400 microns the test was run at high temperature the test was run at high current density Source--Nelson, Wayne and Doganaksoy, Necip (1992). A Computer Program POWNOR for Fitting the Power-Normal and -Lognormal Models to Life or Strength Data from Specimens of Various Sizes. NISTIR 4760, March 1992. Ultimate Source--Harry Shaft, NIST, March 1987 Number of observations = 59 Number of variables per line image = 1 Order of variables per line image-- 1. Response = hours to failure Statistical area--Reliability, Accelerated Testing To read this file into Dataplot-- SKIP 25 READ NELSNIST.DAT Y Hours to Failure ---------------- 6.545 8.120 11.038 7.459 5.807 8.336 6.948 10.092 7.224 6.515 9.289 4.706 5.381 7.495 6.725 9.218 9.254 7.496 7.365 6.476 7.543 8.687 6.958 6.573 8.532 7.945 5.009 4.531 6.923 6.071 6.956 2.997 4.288 6.538 9.663 6.869 7.489 7.974 5.640 10.491 6.492 8.591 6.522 5.589 6.369 6.352 7.398 8.799 5.434 5.923 5.459 6.129 4.137 6.087 7.024 4.700 6.033 7.683 7.937