zabbix_export: version: '6.0' date: '2021-11-21T21:33:28Z' groups: - uuid: 4974e8420026414287b88dcc314a033e name: Terphane/Switches templates: - uuid: 3e2d159875c544d5a77d3181c7563f40 template: 'BROCADE FIBER CHANNEL SWITCH' name: 'BROCADE FIBER CHANNEL SWITCH' description: | ## Overview Unnoficial template created and used by me. This template allows you to monitor your Brocade 300's fans, power supply, status of temperature, temperature on sensors and the system's uptime. This template does NOT monitor any interfaces. If you want to do so, and don't know how, please feel free to contact me by email, and I will be glad to help you. marcelo1302a@gmail.com ## Author Marcelo F. Salvatori groups: - name: Terphane/Switches items: - uuid: 527db55bf56841829b5364658815fa94 name: 'Temperature on Sensor 1' type: SNMP_AGENT snmp_oid: .1.3.6.1.4.1.1588.2.1.1.1.1.22.1.4.1 key: swSensorInfo.1 delay: '300' units: Celsius tags: - tag: Application value: 'Status of Temperature' triggers: - uuid: fb8b55530bad414282bebcc5a9e342e0 expression: 'last(/BROCADE FIBER CHANNEL SWITCH/swSensorInfo.1)>40' name: '{HOST.NAME} is above limit' priority: HIGH manual_close: 'YES' - uuid: 532f15216faf4ed1a0ec89a7cd4dca19 name: 'Temperature on Sensor 2' type: SNMP_AGENT snmp_oid: .1.3.6.1.4.1.1588.2.1.1.1.1.22.1.4.2 key: swSensorInfo.2 delay: '300' units: Celsius tags: - tag: Application value: 'Status of Temperature' triggers: - uuid: a76c13c6916a426f85c6d7083503460f expression: 'last(/BROCADE FIBER CHANNEL SWITCH/swSensorInfo.2)>40' name: '{HOST.NAME} is above limit' priority: HIGH manual_close: 'YES' - uuid: 0a28fca2a5ab4a638db985f237d1c68c name: 'Temperature on Sensor 3' type: SNMP_AGENT snmp_oid: .1.3.6.1.4.1.1588.2.1.1.1.1.22.1.4.3 key: swSensorInfo.3 delay: '300' units: Celsius tags: - tag: Application value: 'Status of Temperature' triggers: - uuid: d03f7405a7454db2810982fa0f7a519a expression: 'last(/BROCADE FIBER CHANNEL SWITCH/swSensorInfo.3)>40' name: '{HOST.NAME} is above limit' priority: HIGH manual_close: 'YES' - uuid: c0def07944f9473c86f1b642537bd67e name: 'Speed of FAN 1' type: SNMP_AGENT snmp_oid: .1.3.6.1.4.1.1588.2.1.1.1.1.22.1.4.4 key: swSensorInfo.4 delay: '300' units: RPM tags: - tag: Application value: FANS - uuid: 42677a35605c48e88e6aa3e39728d252 name: 'Speed of FAN 2' type: SNMP_AGENT snmp_oid: .1.3.6.1.4.1.1588.2.1.1.1.1.22.1.4.5 key: swSensorInfo.5 delay: '300' units: RPM tags: - tag: Application value: FANS - uuid: e08dc04659b846d6b37fd203a93ccf54 name: 'Speed of FAN 3' type: SNMP_AGENT snmp_oid: .1.3.6.1.4.1.1588.2.1.1.1.1.22.1.4.6 key: swSensorInfo.6 delay: '300' units: RPM tags: - tag: Application value: FANS - uuid: 174a9ee276d74e6b89695aafae952ca7 name: 'Status of Temperature Sensor 1' type: SNMP_AGENT snmp_oid: .1.3.6.1.4.1.1588.2.1.1.1.1.22.1.3.1 key: swSensorStatus.1 delay: '300' valuemap: name: 'Brocade sensor status' tags: - tag: Application value: 'Status of Temperature' triggers: - uuid: d27a6834522b47c0a7a74522e0b7f178 expression: 'last(/BROCADE FIBER CHANNEL SWITCH/swSensorStatus.1)=2' name: '{HOST.NAME} is faulty' priority: HIGH manual_close: 'YES' - uuid: 0e3f630ab16341e3bc068cb36b5b8fe8 name: 'Status of Temperature Sensor 2' type: SNMP_AGENT snmp_oid: .1.3.6.1.4.1.1588.2.1.1.1.1.22.1.3.2 key: swSensorStatus.2 delay: '300' valuemap: name: 'Brocade sensor status' tags: - tag: Application value: 'Status of Temperature' triggers: - uuid: 56a0aeede8bd44ada06b156ca39c80ce expression: 'last(/BROCADE FIBER CHANNEL SWITCH/swSensorStatus.2)=2' name: '{HOST.NAME} is faulty' priority: HIGH manual_close: 'YES' - uuid: 1c761ed76ad74ac495763098e66c07da name: 'Status of Temperature Sensor 3' type: SNMP_AGENT snmp_oid: .1.3.6.1.4.1.1588.2.1.1.1.1.22.1.3.3 key: swSensorStatus.3 delay: '300' valuemap: name: 'Brocade sensor status' tags: - tag: Application value: 'Status of Temperature' triggers: - uuid: e45042fe75bd46fc985f2e1a824058ed expression: 'last(/BROCADE FIBER CHANNEL SWITCH/swSensorStatus.3)=2' name: '{HOST.NAME} is faulty' priority: HIGH manual_close: 'YES' - uuid: 1dc947ccd6aa4deb9fea493f8deed95c name: 'Status of FAN 1' type: SNMP_AGENT snmp_oid: .1.3.6.1.4.1.1588.2.1.1.1.1.22.1.3.4 key: swSensorStatus.4 delay: '300' valuemap: name: 'Brocade sensor status' tags: - tag: Application value: FANS triggers: - uuid: 6d8f569fe23c471c8b06f1c1460cfb05 expression: 'last(/BROCADE FIBER CHANNEL SWITCH/swSensorStatus.4)=2' name: '{HOST.NAME} is faulty' priority: HIGH manual_close: 'YES' - uuid: 508126755b1e40e99c20961c91feb3b7 name: 'Status of FAN 2' type: SNMP_AGENT snmp_oid: .1.3.6.1.4.1.1588.2.1.1.1.1.22.1.3.5 key: swSensorStatus.5 delay: '300' valuemap: name: 'Brocade sensor status' tags: - tag: Application value: FANS triggers: - uuid: 0c926e91a1a843c48414f4defc4eb3fe expression: 'last(/BROCADE FIBER CHANNEL SWITCH/swSensorStatus.5)=2' name: '{HOST.NAME} is faulty' priority: HIGH manual_close: 'YES' - uuid: b52f1336b8ca4205b28a4f3cc93de4ec name: 'Status of FAN 3' type: SNMP_AGENT snmp_oid: .1.3.6.1.4.1.1588.2.1.1.1.1.22.1.3.6 key: swSensorStatus.6 delay: '300' valuemap: name: 'Brocade sensor status' tags: - tag: Application value: FANS triggers: - uuid: 98afa53ac6ff4abda0d583fb68aa431a expression: 'last(/BROCADE FIBER CHANNEL SWITCH/swSensorStatus.6)=2' name: '{HOST.NAME} is faulty' priority: HIGH manual_close: 'YES' - uuid: 8083deb789f84a6b95deace4743875fc name: 'Status of Power Supply' type: SNMP_AGENT snmp_oid: .1.3.6.1.4.1.1588.2.1.1.1.1.22.1.3.7 key: swSensorStatus.7 delay: '300' valuemap: name: 'Brocade sensor status' tags: - tag: Application value: 'Power Supply' - uuid: cdd92ef6ce3c4b079f4a3dc5fe6c86a7 name: 'System uptime' type: SNMP_AGENT snmp_oid: .1.3.6.1.2.1.1.3.0 key: sysUpTimeInstance delay: '300' units: uptime tags: - tag: Application value: Stacking valuemaps: - uuid: 73ea7dc13397404d9a8df3f135ff6501 name: 'Brocade sensor status' mappings: - value: '1' newvalue: Unknown - value: '2' newvalue: Faulty - value: '3' newvalue: Below-min - value: '4' newvalue: Nominal - value: '5' newvalue: Above-max - value: '6' newvalue: Absent