zabbix_export: version: '6.0' date: '2021-11-21T22:04:43Z' groups: - uuid: e0242822f07b4633a283b8dc935d3dd9 name: Templates_Created templates: - uuid: 9575db730e5e4b1bab24ea5940cc6313 template: 'Cisco 7600 Health SNMP' name: 'Cisco 7600 Health SNMP' description: | ## Description Template Cisco 7600 Health -CPU -Memory -PowerSupply -PowerConsumption -Temperature -FAN -CEF By: Flavio Gomes Figueira Camacho Junior Require: Firmware / Software .IOS rp-ADVENTERPRISEK9-M 15.2(4)S4 ValueMaps .CISCO-ENVMON-MIB::CiscoEnvMonState .ENTITY-SENSORS-MIB::EntitySensorStatus .CISCO-CEF-TC-MIB::CefFailureReason Base: CISCO-ENVMON-MIB.mib http://www.circitor.fr/Mibs/Html/C/CISCO-ENVMON-MIB.php CISCO-MEMORY-POOL-MIB.mib http://www.circitor.fr/Mibs/Html/C/CISCO-MEMORY-POOL-MIB.php CISCO-PROCESS-MIB.mib http://www.circitor.fr/Mibs/Html/C/CISCO-PROCESS-MIB.php ENTITY-MIB.mib http://www.circitor.fr/Mibs/Html/E/ENTITY-MIB.php CISCO-ENTITY-SENSOR-MIB.mib http://www.circitor.fr/Mibs/Html/C/CISCO-ENTITY-SENSOR-MIB.php CISCO-ENTITY-FRU-CONTROL-MIB.mib http://www.circitor.fr/Mibs/Html/C/CISCO-ENTITY-FRU-CONTROL-MIB.php CISCO-CEF-MIB.mib http://www.circitor.fr/Mibs/Html/C/CISCO-CEF-MIB.php https://share.zabbix.com/network_devices/cisco/template-cisco-7600 External Scripts and Value Mapping on my Github: https://github.com/flaviojunior1995/Zabbix-Templates ## Overview Template Cisco 7600 Health -CPU -Memory -PowerSupply -PowerConsumption -Temperature -FAN -CEF By: Flavio Gomes Figueira Camacho Junior Require: Firmware / Software .IOS rp-ADVENTERPRISEK9-M 15.2(4)S4 ValueMaps .CISCO-ENVMON-MIB::CiscoEnvMonState .ENTITY-SENSORS-MIB::EntitySensorStatus .CISCO-CEF-TC-MIB::CefFailureReason Base: CISCO-ENVMON-MIB.mib http://www.circitor.fr/Mibs/Html/C/CISCO-ENVMON-MIB.php CISCO-MEMORY-POOL-MIB.mib http://www.circitor.fr/Mibs/Html/C/CISCO-MEMORY-POOL-MIB.php CISCO-PROCESS-MIB.mib http://www.circitor.fr/Mibs/Html/C/CISCO-PROCESS-MIB.php ENTITY-MIB.mib http://www.circitor.fr/Mibs/Html/E/ENTITY-MIB.php CISCO-ENTITY-SENSOR-MIB.mib http://www.circitor.fr/Mibs/Html/C/CISCO-ENTITY-SENSOR-MIB.php CISCO-ENTITY-FRU-CONTROL-MIB.mib http://www.circitor.fr/Mibs/Html/C/CISCO-ENTITY-FRU-CONTROL-MIB.php CISCO-CEF-MIB.mib http://www.circitor.fr/Mibs/Html/C/CISCO-CEF-MIB.php https://share.zabbix.com/network\_devices/cisco/template-cisco-7600 External Scripts and Value Mapping on my Github: https://github.com/flaviojunior1995/Zabbix-Templates ## Author Flavio Camacho Junior groups: - name: Templates_Created discovery_rules: - uuid: 53cf3a7030f24da19e9d98ec6c8d215f name: 'Power Comsumption Discovery' type: SNMP_AGENT snmp_oid: 'discovery[{#SNMPVALUE},.1.3.6.1.4.1.9.9.117.1.8.2.1.1]' key: 'cefcConnectorRating["Power Consumption"]' delay: 1h description: CISCO-ENTITY-FRU-CONTROL-MIB item_prototypes: - uuid: c3052045692b4428adf2ccebdfbc0d00 name: 'Module "$1" Voltage (V)' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.9.9.117.1.8.1.1.1.{#SNMPINDEX}' key: 'cefcConnectorRating["{#SNMPINDEX}"]' delay: 5m history: 30d trends: '0' value_type: FLOAT units: V preprocessing: - type: MULTIPLIER parameters: - '0.01' tags: - tag: Application value: 'Power Consumption' - uuid: 9ef5fa9fd4a84b088abd0e00a65fd73d name: 'Module "$1" Current (A)' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.9.9.117.1.8.2.1.1.{#SNMPINDEX}' key: 'cefcModulePowerConsumptionTable["{#SNMPINDEX}"]' delay: 5m history: 30d trends: '0' value_type: FLOAT units: A preprocessing: - type: MULTIPLIER parameters: - '0.01' tags: - tag: Application value: 'Power Consumption' - uuid: 9579fc70f2fc475b83500279d68f3a54 name: 'Module "$1" Power (W)' type: CALCULATED key: 'moduleComsumption["{#SNMPINDEX}"]' delay: 5m value_type: FLOAT units: W params: 'last(//cefcModulePowerConsumptionTable["{#SNMPINDEX}"]) * last(//cefcConnectorRating["{#SNMPINDEX}"])' tags: - tag: Application value: 'Power Consumption' graph_prototypes: - uuid: e46f208b37ef400d9ee1cc4d804b72b3 name: 'Module {#SNMPINDEX} Power (W)' graph_items: - drawtype: GRADIENT_LINE color: FF0000 item: host: 'Cisco 7600 Health SNMP' key: 'moduleComsumption["{#SNMPINDEX}"]' - sortorder: '1' color: FFFF00 item: host: 'Cisco 7600 Health SNMP' key: 'cefcModulePowerConsumptionTable["{#SNMPINDEX}"]' - sortorder: '2' color: 00FF00 item: host: 'Cisco 7600 Health SNMP' key: 'cefcConnectorRating["{#SNMPINDEX}"]' - uuid: 36b47bd05caa4c05862e56e4e5b31ba7 name: 'CEF Discovery' type: SNMP_AGENT snmp_oid: 'discovery[{#SNMPVALUE},.1.3.6.1.4.1.9.9.492.1.4.2.1.2]' key: 'cefResourceFailureReason["CEF"]' delay: 1h item_prototypes: - uuid: c774db0dc8ed4275a72d5b7bb6fd89d4 name: 'CEF Failure Reason "$1"' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.9.9.492.1.4.2.1.2.{#SNMPINDEX}' key: 'cefResourceFailureReason["{#SNMPINDEX}"]' history: 30d trends: '0' valuemap: name: 'CISCO-CEF-TC-MIB::CefFailureReason' tags: - tag: Application value: CEF trigger_prototypes: - uuid: a1c660f5a0ee4683af6a63da7ebe8351 expression: 'last(/Cisco 7600 Health SNMP/cefResourceFailureReason["{#SNMPINDEX}"])<>1' name: 'CEF Failure' priority: DISASTER - uuid: a777c8524c9c4c52b2a2732c24746902 name: 'CEF Memory Used "$1"' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.9.9.492.1.4.2.1.1.{#SNMPINDEX}' key: 'cefResourceMemoryUsed["{#SNMPINDEX}"]' history: 30d value_type: FLOAT units: B tags: - tag: Application value: CEF - tag: Application value: Memory trigger_prototypes: - uuid: d54bd0f92e474f308c77fbb3ab666f54 expression: '{$CEF_TOTAL_MEMORY} * 100 / last(/Cisco 7600 Health SNMP/cefResourceMemoryUsed["{#SNMPINDEX}"]) > 90' name: 'CEF high memory utilization' priority: HIGH graph_prototypes: - uuid: 4c7b6c78f85c46d09d0b21bbe01573d2 name: 'CEF Memory Used {#SNMPINDEX}' graph_items: - drawtype: GRADIENT_LINE color: 00FF00 item: host: 'Cisco 7600 Health SNMP' key: 'cefResourceMemoryUsed["{#SNMPINDEX}"]' - uuid: 816ba3e01954442ca8fdb9d68b80da5b name: 'FAN Discovery' type: SNMP_AGENT snmp_oid: 'discovery[{#SNMPVALUE},.1.3.6.1.4.1.9.9.13.1.4.1.2]' key: 'ciscoEnvMonFanStatusDescr["FAN"]' delay: 1h description: | CISCO-ENVMON-MIB The table of fan status maintained by the environmental monitor. item_prototypes: - uuid: 46a0bca81d2945509e462c8bb0428488 name: '"{#SNMPVALUE}": Fan status' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.9.9.13.1.4.1.3.{#SNMPINDEX}' key: 'ciscoEnvMonFanState["{#SNMPINDEX}"]' history: 30d trends: '0' description: 'MIB: CISCO-ENVMON-MIB' valuemap: name: 'CISCO-ENVMON-MIB::CiscoEnvMonState' tags: - tag: Application value: FAN trigger_prototypes: - uuid: 371320c869a74e6bae737aff74fc2761 expression: 'last(/Cisco 7600 Health SNMP/ciscoEnvMonFanState["{#SNMPINDEX}"])=3' name: '"{#SNMPVALUE}": Fan is in critical state' priority: HIGH description: | Last value: {ITEM.LASTVALUE1}. Please check the fan unit - uuid: 18b4a8ae430242b5ae61e472b4d5ffdc expression: 'last(/Cisco 7600 Health SNMP/ciscoEnvMonFanState["{#SNMPINDEX}"])=2' name: '"{#SNMPVALUE}": Fan is in warning state' priority: WARNING - uuid: a96b29b9a504414fba4a0766f5e9ccb0 expression: 'last(/Cisco 7600 Health SNMP/ciscoEnvMonFanState["{#SNMPINDEX}"])=6' name: '"{#SNMPVALUE}": Fan is notFunctioning' priority: WARNING - uuid: ea7ad5fd7e8d4f8cbf7bd3146e71e4ad expression: 'last(/Cisco 7600 Health SNMP/ciscoEnvMonFanState["{#SNMPINDEX}"])=5' name: '"{#SNMPVALUE}": Fan is notPresent' priority: WARNING - uuid: d02d049603ee4f5fb0c0256e996d6541 expression: 'last(/Cisco 7600 Health SNMP/ciscoEnvMonFanState["{#SNMPINDEX}"])=4' name: '"{#SNMPVALUE}": Fan is shutdown' priority: INFO - uuid: 63ef36819bcf482a818f8b3c4421b078 name: 'Power Supply Discovery' type: SNMP_AGENT snmp_oid: 'discovery[{#SNMPVALUE},.1.3.6.1.4.1.9.9.13.1.5.1.2]' key: 'ciscoEnvMonSupplyStatusDescr["Power Supply"]' delay: 1h description: | CISCO-ENVMON-MIB::ciscoEnvMonSupplyStatusDescr Textual description of the power supply being instrumented. item_prototypes: - uuid: bd31e9ff242641b5a5783eb119e68489 name: 'Status "$1"' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.9.9.13.1.5.1.3.{#SNMPINDEX}' key: 'ciscoEnvMonSupplyState["{#SNMPVALUE}"]' history: 30d trends: '0' description: | CISCO-ENVMON-MIB::ciscoEnvMonSupplyState The current state of the power supply being instrumented. valuemap: name: 'CISCO-ENVMON-MIB::CiscoEnvMonState' tags: - tag: Application value: 'Power Supply' trigger_prototypes: - uuid: a86524e6532a40e083dabb383f6c3011 expression: 'last(/Cisco 7600 Health SNMP/ciscoEnvMonSupplyState["{#SNMPVALUE}"])=3' name: 'Status "{#SNMPVALUE}" is critical' priority: HIGH - uuid: 4d307e48bfa64b20a1e10209ce494c0c expression: 'last(/Cisco 7600 Health SNMP/ciscoEnvMonSupplyState["{#SNMPVALUE}"])=2' name: 'Status "{#SNMPVALUE}" is non-operable' priority: WARNING - uuid: ee0ef681c1f54efdbebfb6c289948c06 expression: 'last(/Cisco 7600 Health SNMP/ciscoEnvMonSupplyState["{#SNMPVALUE}"])=6' name: 'Status "{#SNMPVALUE}" is not functioning' priority: AVERAGE - uuid: d2b051f0a7f14bb4afe3eca9b95f5c0e expression: 'last(/Cisco 7600 Health SNMP/ciscoEnvMonSupplyState["{#SNMPVALUE}"])=4' name: 'Status "{#SNMPVALUE}" is shutdown' priority: AVERAGE - uuid: 36805ffed66b4d8983cb376ac9f1283f name: 'Memory Pool Discovery' type: SNMP_AGENT snmp_oid: 'discovery[{#SNMPVALUE},.1.3.6.1.4.1.9.9.48.1.1.1.2]' key: 'ciscoMemoryPoolName["Memory"]' delay: 1h description: | CISCO-MEMORY-POOL-MIB::ciscoMemoryPoolName A textual name assigned to the memory pool. item_prototypes: - uuid: fb88339641764ca695d44513fe4c61d3 name: 'Free memory on Memory Pool "$1"' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.9.9.48.1.1.1.6.{#SNMPINDEX}' key: 'ciscoMemoryPoolFree["{#SNMPVALUE}"]' delay: 5m units: B description: | CISCO-MEMORY-POOL-MIB::ciscoMemoryPoolFree Indicates the number of bytes from the memory pool that are currently unused on the managed device. tags: - tag: Application value: Memory - tag: Application value: 'Memory {#SNMPVALUE}' - uuid: e8003c21cf984aa295fb773bddb05731 name: 'Total Memory Pool "$1"' type: CALCULATED key: 'ciscoMemoryPoolTotal["{#SNMPVALUE}"]' delay: 1h history: 7d trends: 180d units: B params: 'last(//ciscoMemoryPoolFree["{#SNMPVALUE}"]) + last(//ciscoMemoryPoolUsed["{#SNMPVALUE}"])' tags: - tag: Application value: Memory - tag: Application value: 'Memory {#SNMPVALUE}' - uuid: 120230cf785f4860a462ced5834aed63 name: 'Used memory on Memory Pool "$1"' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.9.9.48.1.1.1.5.{#SNMPINDEX}' key: 'ciscoMemoryPoolUsed["{#SNMPVALUE}"]' delay: 5m units: B description: | CISCO-MEMORY-POOL-MIB::ciscoMemoryPoolUsed Indicates the number of bytes from the memory pool that are currently in use by applications on the managed device. tags: - tag: Application value: Memory - tag: Application value: 'Memory {#SNMPVALUE}' trigger_prototypes: - uuid: 0b73708fe7c74159b75f70816c1491f4 expression: '(last(/Cisco 7600 Health SNMP/ciscoMemoryPoolUsed["{#SNMPVALUE}"])*100 ) / last(/Cisco 7600 Health SNMP/ciscoMemoryPoolTotal["{#SNMPVALUE}"]) > {$MEMORY_HIGH_ALARM}' name: 'High memory utilizarion alarm on Pool "{#SNMPVALUE}"' priority: HIGH - uuid: b32b0102d5a54e50b6f5ac4547a33600 expression: '(last(/Cisco 7600 Health SNMP/ciscoMemoryPoolUsed["{#SNMPVALUE}"])*100 ) / last(/Cisco 7600 Health SNMP/ciscoMemoryPoolTotal["{#SNMPVALUE}"]) > {$MEMORY_HIGH_WARNING}' name: 'High memory utilizarion warning on Pool "{#SNMPVALUE}"' priority: AVERAGE graph_prototypes: - uuid: 6cbb2f2f08b54391ac893ab4c2ad994f name: 'Memory {#SNMPVALUE}' show_work_period: 'NO' show_triggers: 'NO' graph_items: - drawtype: BOLD_LINE color: 00FF00 item: host: 'Cisco 7600 Health SNMP' key: 'ciscoMemoryPoolTotal["{#SNMPVALUE}"]' - sortorder: '1' drawtype: GRADIENT_LINE color: FF0000 item: host: 'Cisco 7600 Health SNMP' key: 'ciscoMemoryPoolUsed["{#SNMPVALUE}"]' - uuid: 692b84729fdf4025a9036d507ccb7dbd name: 'CPU Discovery' type: SNMP_AGENT snmp_oid: 'discovery[{#SNMPVALUE},.1.3.6.1.4.1.9.9.109.1.1.1.1.2]' key: 'cpmCPUTotalPhysicalIndex["CPU"]' delay: 1h description: | CISCO-PROCESS-MIB::cpmCPUTotalPhysicalIndex The entPhysicalIndex of the physical entity for which the CPU statistics in this entry are maintained. The physical entity can be a CPU chip, a group of CPUs, a CPU card etc. The exact type of this entity is described by its entPhysicalVendorType value. If the CPU statistics in this entry correspond to more than one physical entity (or to no physical entity), or if the entPhysicalTable is not supported on the SNMP agent, the value of this object must be zero. item_prototypes: - uuid: e54a93f03b3a4bf48ac9813c1eb683e6 name: 'CPU #"$1" Usage 1min Rev' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.9.9.109.1.1.1.1.7.{#SNMPINDEX}' key: 'cpmCPUTotal1minRev["{#SNMPINDEX}"]' units: '%' description: | CISCO-PROCESS-MIB::cpmCPUTotal1minRev The overall CPU busy percentage in the last 1 minute period. This object deprecates the object cpmCPUTotal1min and increases the value range to (0..100). tags: - tag: Application value: CPU trigger_prototypes: - uuid: 68c9c148ddea46cab5e3c6df2562a35f expression: 'last(/Cisco 7600 Health SNMP/cpmCPUTotal1minRev["{#SNMPINDEX}"])>{$CPU_HIGH_ALARM}' name: 'High CPU Alarm #"{#SNMPINDEX}" 1min Usage' priority: HIGH - uuid: 17cbd948f6c3475a9e84c9c4940d532e expression: 'last(/Cisco 7600 Health SNMP/cpmCPUTotal1minRev["{#SNMPINDEX}"])>{$CPU_HIGH_WARNING}' name: 'High CPU Warning #"{#SNMPINDEX}" 1min Usage' priority: AVERAGE - uuid: 399dfc2a233f4eebafcf6d85a2cb26be name: 'CPU #"$1" Usage 5min Rev' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.9.9.109.1.1.1.1.8.{#SNMPINDEX}' key: 'cpmCPUTotal5minRev["{#SNMPINDEX}"]' delay: 5m units: '%' description: | CISCO-PROCESS-MIB::cpmCPUTotal5minRev The overall CPU busy percentage in the last 5 minute period. This object deprecates the object cpmCPUTotal5min and increases the value range to (0..100). tags: - tag: Application value: CPU trigger_prototypes: - uuid: 0785e37d1989420382feb3787f4bf57c expression: 'last(/Cisco 7600 Health SNMP/cpmCPUTotal5minRev["{#SNMPINDEX}"])>{$CPU_HIGH_ALARM}' name: 'High CPU Alarm #"{#SNMPINDEX}" 5min Usage' priority: HIGH - uuid: 1a89058c055843458a5550091adbd0e4 expression: 'last(/Cisco 7600 Health SNMP/cpmCPUTotal5minRev["{#SNMPINDEX}"])>{$CPU_HIGH_WARNING}' name: 'High CPU Warning #"{#SNMPINDEX}" 5min Usage' priority: AVERAGE graph_prototypes: - uuid: e10e63481224471a94e746d7f371f755 name: 'CPU #"{#SNMPINDEX}" 1min Usage' graph_items: - drawtype: FILLED_REGION color: 00FF00 item: host: 'Cisco 7600 Health SNMP' key: 'cpmCPUTotal1minRev["{#SNMPINDEX}"]' - uuid: 6e260ab6be1f43aab48b831cd443bbc3 name: 'CPU #"{#SNMPINDEX}" 5min Usage' graph_items: - drawtype: FILLED_REGION color: 00FF00 item: host: 'Cisco 7600 Health SNMP' key: 'cpmCPUTotal5minRev["{#SNMPINDEX}"]' - uuid: 1c3e0324364c4b8ab2973367c6c57be6 name: 'Temperature Sensors Discovery' type: SNMP_AGENT snmp_oid: 'discovery[{#SNMPVALUE},.1.3.6.1.2.1.47.1.1.1.1.7]' key: 'entPhysicalName["Temperature"]' delay: 1h filter: evaltype: AND conditions: - macro: '{#SNMPVALUE}' value: temperature formulaid: A - macro: '{#SNMPVALUE}' value: device operator: NOT_MATCHES_REGEX formulaid: B description: 'The textual name of the physical entity.' item_prototypes: - uuid: 600eeaaa3c3f431886751facae5d38f4 name: 'Status Temperature Sensor "$1"' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.9.9.91.1.1.1.1.5.{#SNMPINDEX}' key: 'entSensorStatus["{#SNMPVALUE}"]' history: 30d trends: '0' description: | CISCO-ENTITY-SENSOR-MIB::entSensorStatus This variable indicates the present operational status of the sensor. valuemap: name: 'ENTITY-SENSORS-MIB::EntitySensorStatus' tags: - tag: Application value: Temperature - tag: Application value: 'Temperature {#SNMPVALUE}' trigger_prototypes: - uuid: dd7be66db60d46e1b7e19220b7691e09 expression: 'last(/Cisco 7600 Health SNMP/entSensorStatus["{#SNMPVALUE}"])=3' name: 'Temperature Sensor "{#SNMPVALUE}" is nonoperational' priority: HIGH - uuid: b324cd556bfa46a19ec10792e90c23d0 expression: 'last(/Cisco 7600 Health SNMP/entSensorStatus["{#SNMPVALUE}"])=2' name: 'Temperature Sensor "{#SNMPVALUE}" is unavailable' priority: AVERAGE - uuid: fd3057d3132849d087dcc6d31f5cd8bc name: 'Thresholds::"$1" | Temperature Alarm' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.9.9.91.1.2.1.1.4.{#SNMPINDEX}.2' key: 'entSensorThresholdValue["{#SNMPVALUE}","Alarm"]' delay: 1h history: 7d trends: 180d value_type: FLOAT units: °C description: | CISCO-ENTITY-SENSOR-MIB::entSensorThresholdValue This variable indicates the value of the threshold. tags: - tag: Application value: Temperature - tag: Application value: 'Temperature {#SNMPVALUE}' - uuid: 7cf6b32cc536482ea8949e9d081a892c name: 'Thresholds::"$1" | Temperature Warning' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.9.9.91.1.2.1.1.4.{#SNMPINDEX}.1' key: 'entSensorThresholdValue["{#SNMPVALUE}","Warning"]' delay: 1h history: 7d trends: 180d value_type: FLOAT units: °C description: | CISCO-ENTITY-SENSOR-MIB::entSensorThresholdValue This variable indicates the value of the threshold. tags: - tag: Application value: Temperature - tag: Application value: 'Temperature {#SNMPVALUE}' - uuid: abdfdd8334d248bda1d15caedfa85652 name: 'Temperature on Sensor "$1"' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.9.9.91.1.1.1.1.4.{#SNMPINDEX}' key: 'entSensorValue["{#SNMPVALUE}"]' value_type: FLOAT units: °C description: | CISCO-ENTITY-SENSOR-MIB::entSensorValue This variable reports the most recent measurement seen by the sensor. tags: - tag: Application value: Temperature - tag: Application value: 'Temperature {#SNMPVALUE}' trigger_prototypes: - uuid: 9777efe9e35a4ebd9fb916ec7160b5b9 expression: 'last(/Cisco 7600 Health SNMP/entSensorValue["{#SNMPVALUE}"])>last(/Cisco 7600 Health SNMP/entSensorThresholdValue["{#SNMPVALUE}","Alarm"])' name: 'High Temperature Alarm "{#SNMPVALUE}"' priority: HIGH dependencies: - name: 'Temperature Sensor "{#SNMPVALUE}" is nonoperational' expression: 'last(/Cisco 7600 Health SNMP/entSensorStatus["{#SNMPVALUE}"])=3' - name: 'Temperature Sensor "{#SNMPVALUE}" is unavailable' expression: 'last(/Cisco 7600 Health SNMP/entSensorStatus["{#SNMPVALUE}"])=2' - uuid: 1d8589cb8d17415287612891793abc5f expression: 'last(/Cisco 7600 Health SNMP/entSensorValue["{#SNMPVALUE}"])>last(/Cisco 7600 Health SNMP/entSensorThresholdValue["{#SNMPVALUE}","Warning"])' name: 'High Temperature Warning "{#SNMPVALUE}"' priority: AVERAGE dependencies: - name: 'High Temperature Alarm "{#SNMPVALUE}"' expression: 'last(/Cisco 7600 Health SNMP/entSensorValue["{#SNMPVALUE}"])>last(/Cisco 7600 Health SNMP/entSensorThresholdValue["{#SNMPVALUE}","Alarm"])' - name: 'Temperature Sensor "{#SNMPVALUE}" is nonoperational' expression: 'last(/Cisco 7600 Health SNMP/entSensorStatus["{#SNMPVALUE}"])=3' - name: 'Temperature Sensor "{#SNMPVALUE}" is unavailable' expression: 'last(/Cisco 7600 Health SNMP/entSensorStatus["{#SNMPVALUE}"])=2' graph_prototypes: - uuid: 2a0c2997ef3f4413a2b890d4e7380a8a name: 'Temperature {#SNMPVALUE}' graph_items: - drawtype: GRADIENT_LINE color: 00FF00 item: host: 'Cisco 7600 Health SNMP' key: 'entSensorValue["{#SNMPVALUE}"]' - sortorder: '1' drawtype: BOLD_LINE color: FF0000 item: host: 'Cisco 7600 Health SNMP' key: 'entSensorThresholdValue["{#SNMPVALUE}","Alarm"]' - sortorder: '2' drawtype: BOLD_LINE color: FFFF00 item: host: 'Cisco 7600 Health SNMP' key: 'entSensorThresholdValue["{#SNMPVALUE}","Warning"]' macros: - macro: '{$CEF_TOTAL_MEMORY}' value: '3678072' description: 'total memory CEF' - macro: '{$CPU_HIGH_ALARM}' value: '90' description: '% cpu waning' - macro: '{$CPU_HIGH_WARNING}' value: '70' description: '% cpu alarm' - macro: '{$MEMORY_HIGH_ALARM}' value: '80' description: '% memory alarm' - macro: '{$MEMORY_HIGH_WARNING}' value: '70' description: '% memoty warning' dashboards: - uuid: 7eddf82ddbe948fa991472a532e6bd36 name: 'Screem Power Comsumption' pages: - widgets: - type: GRAPH_PROTOTYPE width: '24' height: '5' fields: - type: INTEGER name: source_type value: '2' - type: INTEGER name: columns value: '1' - type: INTEGER name: rows value: '1' - type: GRAPH_PROTOTYPE name: graphid value: name: 'Module {#SNMPINDEX} Power (W)' host: 'Cisco 7600 Health SNMP' - uuid: bf710306a2134591844c1a5eac95d7ec name: 'Screen CPU' pages: - widgets: - type: GRAPH_PROTOTYPE width: '24' height: '5' fields: - type: INTEGER name: source_type value: '2' - type: INTEGER name: columns value: '1' - type: INTEGER name: rows value: '1' - type: GRAPH_PROTOTYPE name: graphid value: name: 'CPU #"{#SNMPINDEX}" 1min Usage' host: 'Cisco 7600 Health SNMP' - type: GRAPH_PROTOTYPE 'y': '5' width: '24' height: '5' fields: - type: INTEGER name: source_type value: '2' - type: INTEGER name: columns value: '1' - type: INTEGER name: rows value: '1' - type: GRAPH_PROTOTYPE name: graphid value: name: 'CPU #"{#SNMPINDEX}" 5min Usage' host: 'Cisco 7600 Health SNMP' - uuid: 39715289fe9748ce8ddf9ff312455f21 name: 'Screen Memory' pages: - widgets: - type: GRAPH_PROTOTYPE width: '24' height: '5' fields: - type: INTEGER name: source_type value: '2' - type: INTEGER name: columns value: '1' - type: INTEGER name: rows value: '1' - type: GRAPH_PROTOTYPE name: graphid value: name: 'CEF Memory Used {#SNMPINDEX}' host: 'Cisco 7600 Health SNMP' - type: GRAPH_PROTOTYPE 'y': '5' width: '24' height: '5' fields: - type: INTEGER name: source_type value: '2' - type: INTEGER name: columns value: '1' - type: INTEGER name: rows value: '1' - type: GRAPH_PROTOTYPE name: graphid value: name: 'Memory {#SNMPVALUE}' host: 'Cisco 7600 Health SNMP' - uuid: ba3174037c1f4dd28d97770fb326af8d name: 'Screen Power Supply' pages: - widgets: - type: GRAPH_PROTOTYPE width: '24' height: '5' fields: - type: INTEGER name: source_type value: '2' - type: INTEGER name: columns value: '1' - type: INTEGER name: rows value: '1' - type: GRAPH_PROTOTYPE name: graphid value: name: 'Module {#SNMPINDEX} Power (W)' host: 'Cisco 7600 Health SNMP' - uuid: 5d674d53a4f9494fa9847ce366c0a1f8 name: 'Screen Temperature' pages: - widgets: - type: GRAPH_PROTOTYPE width: '24' height: '5' fields: - type: INTEGER name: source_type value: '2' - type: INTEGER name: columns value: '1' - type: INTEGER name: rows value: '1' - type: GRAPH_PROTOTYPE name: graphid value: name: 'Temperature {#SNMPVALUE}' host: 'Cisco 7600 Health SNMP' valuemaps: - uuid: d2942a68aa0f42389b2b2a6d405eae12 name: 'CISCO-CEF-TC-MIB::CefFailureReason' mappings: - value: '1' newvalue: none - value: '2' newvalue: mallocFailure - value: '3' newvalue: hwFailure - value: '4' newvalue: keepaliveFailure - value: '5' newvalue: noMsgBuffer - value: '6' newvalue: invalidMsgSize - value: '7' newvalue: internalError - uuid: 22a804af202843419c4e5620aeee5b9b name: 'CISCO-ENVMON-MIB::CiscoEnvMonState' mappings: - value: '1' newvalue: normal - value: '2' newvalue: warning - value: '3' newvalue: critical - value: '4' newvalue: shutdown - value: '5' newvalue: notPresent - value: '6' newvalue: notFunctioning - uuid: 335ccc547d5c4beb88bdadbeb82605a3 name: 'ENTITY-SENSORS-MIB::EntitySensorStatus' mappings: - value: '1' newvalue: ok - value: '2' newvalue: unavailable - value: '3' newvalue: nonoperational