zabbix_export: version: '6.0' date: '2021-11-21T21:29:12Z' groups: - uuid: 83761f47e4884f74a1c6851e01014167 name: DmOS templates: - uuid: b07e2bb72caf4154b75049787e3dc134 template: 'DmOS - Hardware Monitor' name: 'DmOS - Hardware Monitor' description: | ## Description Monitor de objetos da MIB DMOS-HW-MONITOR-MIB para monitoramento do hardware dos devices. ## Overview Platforms DM4050 and DM4610. SNMP - Sensors Temperature SNMP - FAN Control, FAN Speed ## Author Guilherme Zamora Rodrigues groups: - name: DmOS items: - uuid: 426d86c45350452b8351a1d7a162d734 name: 'DM4050 - FAN1 Control' type: SNMP_AGENT snmp_oid: .1.3.6.1.4.1.3709.3.6.6.1.4.1.3.1.1.49.1.49 key: fanControl.1.1.1 delay: '300' units: '%' tags: - tag: Application value: Speed - uuid: 9b2031ccff0a4aba80a2dbed5b735cc4 name: 'DM4050 - FAN2 Control' type: SNMP_AGENT snmp_oid: .1.3.6.1.4.1.3709.3.6.6.1.4.1.3.1.1.49.1.50 key: fanControl.1.1.2 delay: '300' units: '%' tags: - tag: Application value: Speed - uuid: 37ffc311ef3341d09ae16a3add32f9c3 name: 'DM4050 - FAN3 Control' type: SNMP_AGENT snmp_oid: .1.3.6.1.4.1.3709.3.6.6.1.4.1.3.1.1.49.1.51 key: fanControl.1.1.3 delay: '300' units: '%' tags: - tag: Application value: Speed - uuid: f7787e889c114c89a2ddf57e3f1ed47c name: 'DM4610 - FAN1 Control' type: SNMP_AGENT snmp_oid: .1.3.6.1.4.1.3709.3.6.6.1.4.1.3.1.3.70.65.78.1.49 key: fanControl.1.FAN.1.49 delay: '300' units: '%' tags: - tag: Application value: Speed - uuid: e0278d5574b04b8ab524efdace6c66cd name: 'DM4610 - FAN2 Control' type: SNMP_AGENT snmp_oid: .1.3.6.1.4.1.3709.3.6.6.1.4.1.3.1.3.70.65.78.1.50 key: fanControl.1.FAN.1.50 delay: '300' units: '%' tags: - tag: Application value: Speed - uuid: 5a1fc17881a942849dc8ea7d6ea8eb9b name: 'DM4610 - FAN3 Control' type: SNMP_AGENT snmp_oid: .1.3.6.1.4.1.3709.3.6.6.1.4.1.3.1.3.70.65.78.1.51 key: fanControl.1.FAN.1.51 delay: '300' units: '%' tags: - tag: Application value: Speed - uuid: ef15313fa8c04920bc2dee2945218a8d name: 'DM4050 - FAN1 Speed' type: SNMP_AGENT snmp_oid: .1.3.6.1.4.1.3709.3.6.6.1.4.1.4.1.1.49.1.49 key: fanSpeed.1.1.1 delay: '300' units: RPM tags: - tag: Application value: Speed - uuid: a3292dd6db3b42b9894f93ae6af7e5e7 name: 'DM4050 - FAN2 Speed' type: SNMP_AGENT snmp_oid: .1.3.6.1.4.1.3709.3.6.6.1.4.1.4.1.1.49.1.50 key: fanSpeed.1.1.2 delay: '300' units: RPM tags: - tag: Application value: Speed - uuid: 80fa6e3bfaf24a99949738c8476b18fb name: 'DM4050 - FAN3 Speed' type: SNMP_AGENT snmp_oid: .1.3.6.1.4.1.3709.3.6.6.1.4.1.4.1.1.49.1.51 key: fanSpeed.1.1.3 delay: '300' units: RPM tags: - tag: Application value: Speed - uuid: 46e3ecb1a36749338a00b402f8458a7e name: 'DM4610 - FAN1 Speed' type: SNMP_AGENT snmp_oid: .1.3.6.1.4.1.3709.3.6.6.1.4.1.4.1.3.70.65.78.1.49 key: fanSpeed.1.49 delay: '300' units: RPM tags: - tag: Application value: Speed - uuid: 31c8973d2c1643e5bb4b9cb8a9883229 name: 'DM4610 - FAN2 Speed' type: SNMP_AGENT snmp_oid: .1.3.6.1.4.1.3709.3.6.6.1.4.1.4.1.3.70.65.78.1.50 key: fanSpeed.1.50 delay: '300' units: RPM tags: - tag: Application value: Speed - uuid: a3179f5413ed4ab7a905e4f9cf6c361d name: 'DM4610 - FAN3 Speed' type: SNMP_AGENT snmp_oid: .1.3.6.1.4.1.3709.3.6.6.1.4.1.4.1.3.70.65.78.1.51 key: fanSpeed.1.51 delay: '300' units: RPM tags: - tag: Application value: Speed - uuid: ec90e67dfbf4499da0943c508282ae03 name: 'Card Temperature' type: SNMP_AGENT snmp_oid: .1.3.6.1.4.1.3709.3.6.6.1.3.1.6.1.1.49.7.83.69.78.83.79.82.49 key: temperatureSensorCurrentTemperature.1.1.7.83.69.78.83.79.82.49 delay: '300' units: °C preprocessing: - type: MULTIPLIER parameters: - '0.10' tags: - tag: Application value: Temp - uuid: 884d6cce321a4749b66742203b29be2b name: 'Switch Fabric Temperature' type: SNMP_AGENT snmp_oid: .1.3.6.1.4.1.3709.3.6.6.1.3.1.6.1.1.49.7.83.69.78.83.79.82.50 key: temperatureSensorCurrentTemperature.1.1.7.83.69.78.83.79.82.50 delay: '300' units: °C preprocessing: - type: MULTIPLIER parameters: - '0.10' tags: - tag: Application value: Temp - uuid: 8442da12b9a24616ac8ac848634f6368 name: 'GPON PHY/SFP Temperature' type: SNMP_AGENT snmp_oid: .1.3.6.1.4.1.3709.3.6.6.1.3.1.6.1.1.49.7.83.69.78.83.79.82.51 key: temperatureSensorCurrentTemperature.1.1.7.83.69.78.83.79.82.51 delay: '300' units: °C preprocessing: - type: MULTIPLIER parameters: - '0.10' tags: - tag: Application value: Temp - uuid: 32d9673c386a453aadb7fd36f1a5d4a3 name: 'CPU Temperature' type: SNMP_AGENT snmp_oid: .1.3.6.1.4.1.3709.3.6.6.1.3.1.6.1.1.49.7.83.69.78.83.79.82.52 key: temperatureSensorCurrentTemperature.1.1.7.83.69.78.83.79.82.52 delay: '300' units: °C preprocessing: - type: MULTIPLIER parameters: - '0.10' tags: - tag: Application value: Temp - uuid: 1058284235544223afa28079da5c70c3 name: 'CPU Core Temperature' type: SNMP_AGENT snmp_oid: .1.3.6.1.4.1.3709.3.6.6.1.3.1.6.1.1.49.7.83.69.78.83.79.82.53 key: temperatureSensorCurrentTemperature.1.1.7.83.69.78.83.79.82.53 delay: '300' units: °C preprocessing: - type: MULTIPLIER parameters: - '0.10' tags: - tag: Application value: Temp - uuid: 31e5a7b06fd74b9580075858bf6361a9 name: 'DM4050 - PSU1 Temperature' type: SNMP_AGENT snmp_oid: .1.3.6.1.4.1.3709.3.6.6.1.3.1.6.1.4.80.83.85.49.7.83.69.78.83.79.82.49 key: temperatureSensorCurrentTemperature.1.1.PSU1 delay: '300' units: °C preprocessing: - type: MULTIPLIER parameters: - '0.10' tags: - tag: Application value: Temp - uuid: 1b9e49fea7ff4fb7850d559e0f2c9375 name: 'DM4050 - Switch Fabric Temperature' type: SNMP_AGENT snmp_oid: .1.3.6.1.4.1.3709.3.6.6.1.3.1.6.1.1.49.7.83.69.78.83.79.82.49 key: temperatureSensorCurrentTemperature.1.1.SENSOR1 delay: '300' units: °C preprocessing: - type: MULTIPLIER parameters: - '0.10' tags: - tag: Application value: Temp - uuid: f5ae148488ee433798006b7d25296be4 name: 'DM4050 - CPU Temperature' type: SNMP_AGENT snmp_oid: .1.3.6.1.4.1.3709.3.6.6.1.3.1.6.1.1.49.7.83.69.78.83.79.82.50 key: temperatureSensorCurrentTemperature.1.1.SENSOR2 delay: '300' units: °C preprocessing: - type: MULTIPLIER parameters: - '0.10' tags: - tag: Application value: Temp - uuid: b0da962d6f5e4eb593f93e00cb2a6ea8 name: 'PSU1 Temperature' type: SNMP_AGENT snmp_oid: .1.3.6.1.4.1.3709.3.6.6.1.3.1.6.1.4.80.83.85.49.7.83.69.78.83.79.82.49 key: temperatureSensorCurrentTemperature.1.PSU1.7.83.69.78.83.79.82.49 delay: '300' units: °C preprocessing: - type: MULTIPLIER parameters: - '0.10' tags: - tag: Application value: Temp - uuid: 74ec55f5a1964fe492c8e342cc8c5f57 name: 'PSU2 Temperature' type: SNMP_AGENT snmp_oid: .1.3.6.1.4.1.3709.3.6.6.1.3.1.6.1.4.80.83.85.50.7.83.69.78.83.79.82.49 key: temperatureSensorCurrentTemperature.1.PSU2.7.83.69.78.83.79.82.49 delay: '300' units: °C preprocessing: - type: MULTIPLIER parameters: - '0.10' tags: - tag: Application value: Temp - uuid: b50aec372214469fa12cbb2d674fd5bd name: 'DM4050 - CPU Core Temperature' type: SNMP_AGENT snmp_oid: .1.3.6.1.4.1.3709.3.6.6.1.3.1.6.1.1.49.7.83.69.78.83.79.82.51 key: temperatureSensorCurrentTemperature.CPUCore delay: '300' units: °C preprocessing: - type: MULTIPLIER parameters: - '0.10' tags: - tag: Application value: Temp graphs: - uuid: 2880cc651ccf47299dc6ce422ae3750f name: 'DM4050 - SNMP - FAN Control' graph_items: - drawtype: GRADIENT_LINE color: 1A7C11 item: host: 'DmOS - Hardware Monitor' key: fanControl.1.1.1 - sortorder: '1' drawtype: GRADIENT_LINE color: F63100 item: host: 'DmOS - Hardware Monitor' key: fanControl.1.1.2 - sortorder: '2' drawtype: GRADIENT_LINE color: 2774A4 item: host: 'DmOS - Hardware Monitor' key: fanControl.1.1.3 - uuid: 6aa3db8dc19e448684b677ffa9768aa3 name: 'DM4050 - SNMP - FAN Speed' graph_items: - color: 1A7C11 item: host: 'DmOS - Hardware Monitor' key: fanSpeed.1.1.1 - sortorder: '1' color: F63100 item: host: 'DmOS - Hardware Monitor' key: fanSpeed.1.1.2 - sortorder: '2' color: 2774A4 item: host: 'DmOS - Hardware Monitor' key: fanSpeed.1.1.3 - uuid: 33edef5e54d74b00a2c1191ec6847cff name: 'DM4610 - SNMP - FAN Control' graph_items: - drawtype: GRADIENT_LINE color: 1A7C11 item: host: 'DmOS - Hardware Monitor' key: fanControl.1.FAN.1.49 - sortorder: '1' drawtype: GRADIENT_LINE color: F63100 item: host: 'DmOS - Hardware Monitor' key: fanControl.1.FAN.1.50 - sortorder: '2' drawtype: GRADIENT_LINE color: 2774A4 item: host: 'DmOS - Hardware Monitor' key: fanControl.1.FAN.1.51 - uuid: 4d3afbf74b3a4c859e92968a0d6f7dae name: 'DM4610 - SNMP - FAN Speed' graph_items: - color: 1A7C11 item: host: 'DmOS - Hardware Monitor' key: fanSpeed.1.49 - sortorder: '1' color: F63100 item: host: 'DmOS - Hardware Monitor' key: fanSpeed.1.50 - sortorder: '2' color: 2774A4 item: host: 'DmOS - Hardware Monitor' key: fanSpeed.1.51 - uuid: 61e1835e1ccf45c79cc8eae0a883014a name: 'DM4610 - SNMP - Sensors Current Temperature' graph_items: - color: 1A7C11 item: host: 'DmOS - Hardware Monitor' key: temperatureSensorCurrentTemperature.1.1.7.83.69.78.83.79.82.49 - sortorder: '1' color: F63100 item: host: 'DmOS - Hardware Monitor' key: temperatureSensorCurrentTemperature.1.1.7.83.69.78.83.79.82.53 - sortorder: '2' color: 2774A4 item: host: 'DmOS - Hardware Monitor' key: temperatureSensorCurrentTemperature.1.1.7.83.69.78.83.79.82.52 - sortorder: '3' color: A54F10 item: host: 'DmOS - Hardware Monitor' key: temperatureSensorCurrentTemperature.1.1.7.83.69.78.83.79.82.51 - sortorder: '4' color: FC6EA3 item: host: 'DmOS - Hardware Monitor' key: temperatureSensorCurrentTemperature.1.1.7.83.69.78.83.79.82.50