zabbix_export: version: '5.4' date: '2021-11-21T21:40:36Z' groups: - uuid: 7df96b18c230490a9a0a9e2307226338 name: Templates templates: - uuid: fcb9dfc5923b4dfd8d4b29e01f72b9ff template: 'SNMP HP MSA 2040 SAN' name: 'SNMP HP MSA 2040 SAN' groups: - name: Templates discovery_rules: - uuid: a070e9474cfc4d55a2585bffaffa71e2 name: 'Connectivity unit info' type: SNMP_AGENT snmp_oid: 'discovery[{#CONNUNITNAME}, 1.3.6.1.3.94.1.6.1.20]' key: connUnitName delay: 24h description: 'A display string containing a name for this connectivity unit. This object value should be persistent between boots.' item_prototypes: - uuid: 633bf37f5e824aeb9aa7cc7b93cef672 name: 'Connectivity unit {#CONNUNITNAME} global ID' type: SNMP_AGENT snmp_oid: '1.3.6.1.3.94.1.6.1.2.{#SNMPINDEX}' key: 'connUnitGlobalID[{#SNMPINDEX}]' delay: 1h trends: '0' value_type: TEXT description: 'An optional global-scope identifier for this connectivity unit. It MUST be a WWN for this connectivity unit or 16 octets of value zero. WWN formats requiring fewer than 16 octets MUST be extended to 16 octets with trailing zero octets, Left justified, zero filled, If a WWN is used for connUnitId, the same WWN MUST be used for connUnitGlobalId. When a non-zero value is provided, it SHOULD be persistent across agent and unit resets. It SHOULD be globally unique. It SHOULD be one of these FC-PH/PH3 formats: IEEE (NAA=1) IEEE Extended (NAA=2) IEEE Registered (NAA=5). IEEE Registered extended (NAA=6). Use of the IEEE formats allows any IEEE-registered vendor to assure global uniqueness independently. The following are some references on IEEE WWN formats: http://standards.ieee.org/regauth/oui/tutorials/fibreformat.html http://standards.ieee.org/regauth/oui/tutorials/fibrecomp_id.html If one or more WWNs are associated with the connUnit via other management methods, one of them SHOULD be used for connUnitGlobalId. If there is not a WWN assigned specifically to the connUnit, there is some merit, though not a requirement, to using a WWN assigned to (one of) its permanently attached FC/LAN interface(s). This can not risk uniqueness, though. As a counterexample, if your agent runs in a host and the host has an HBA, it is quite possible that agent, host, and HBA will all be distinct connUnits, so the host and agent can not use the WWN of the HBA. Another example: If your hub has a built-in Ethernet port, it might be reasonable for the hub to use its MAC address (prefixed with the appropriate NAA) as its connUnitId. But if the Ethernet were a replaceable PCCard, the hub should have an independent ID.' tags: - tag: Application value: 'Connectivity unit information' - uuid: 9e3ef4094d5c47169ba41f7f326f32e5 name: 'Connectivity unit {#CONNUNITNAME} ID' type: SNMP_AGENT snmp_oid: '1.3.6.1.3.94.1.6.1.1.{#SNMPINDEX}' key: 'connUnitID[{#SNMPINDEX}]' delay: 1h trends: '0' value_type: TEXT description: 'The unique identification for this connectivity unit among those within this proxy domain. The value MUST be unique within the proxy domain because it is the index variable for connUnitTable. The value assigned to a given conectivity unit SHOULD be persistent across agent and unit resets. It SHOULD be the same as connUnitGlobalId if connUnitGlobalId is known and stable.' tags: - tag: Application value: 'Connectivity unit information' - uuid: da92f0457fbf4c319d3dc3e74737e1fa name: 'Connectivity unit {#CONNUNITNAME} state' type: SNMP_AGENT snmp_oid: '1.3.6.1.3.94.1.6.1.5.{#SNMPINDEX}' key: 'connUnitState[{#SNMPINDEX}]' delay: 5m description: 'This object reports the overall state of the connectivity unit. The meaning of all values is essentially self-explanatory. Any of these values may occur with any of the ConnUnitStatus values.' valuemap: name: HP2040ConnUnitState tags: - tag: Application value: 'Connectivity unit information' trigger_prototypes: - uuid: 7a81b76048de4562829a2d36cb2ac160 expression: 'last(/SNMP HP MSA 2040 SAN/connUnitState[{#SNMPINDEX}])=3' name: 'Connectivity unit {#CONNUNITNAME} have unknown state' priority: HIGH - uuid: ebecb6a5604847c986780da72c2eb23b name: 'Connectivity unit {#CONNUNITNAME} status' type: SNMP_AGENT snmp_oid: '1.3.6.1.3.94.1.6.1.6.{#SNMPINDEX}' key: 'connUnitStatus[{#SNMPINDEX}]' delay: 5m description: 'Overall status of the connectivity unit. The goal of this object is to be the single poll point to check the status of the connunit. If there is any other component that has warning, then this should be set to warning, etc. Any of these values may occur with any of the ConnUnitState values.' valuemap: name: HP2040ConnUnitStatus tags: - tag: Application value: 'Connectivity unit information' trigger_prototypes: - uuid: 62cfb349620d4ce3b11b3857fe55d199 expression: 'last(/SNMP HP MSA 2040 SAN/connUnitStatus[{#SNMPINDEX}])=5' name: 'Connectivity unit {#CONNUNITNAME} have failed status' priority: HIGH - uuid: 9a9ef807819e4851b7f3beb3b4bf474c expression: 'last(/SNMP HP MSA 2040 SAN/connUnitStatus[{#SNMPINDEX}])=1' name: 'Connectivity unit {#CONNUNITNAME} have unknown status' priority: HIGH - uuid: 0d85da0cf1404aeba9f7cd86b2526a1a expression: 'last(/SNMP HP MSA 2040 SAN/connUnitStatus[{#SNMPINDEX}])=2' name: 'Connectivity unit {#CONNUNITNAME} have unused status' priority: HIGH - uuid: d27db8045b1549f29a6265b0b5c6af6a expression: 'last(/SNMP HP MSA 2040 SAN/connUnitStatus[{#SNMPINDEX}])=4' name: 'Connectivity unit {#CONNUNITNAME} have warning status' priority: HIGH - uuid: c867c00ceca74bb080d010f54e0699e0 name: 'Connectivity unit {#CONNUNITNAME} type' type: SNMP_AGENT snmp_oid: '1.3.6.1.3.94.1.6.1.3.{#SNMPINDEX}' key: 'connUnitType[{#SNMPINDEX}]' delay: 1h description: 'The type of this connectivity unit.' valuemap: name: HP2040ConnUnitType tags: - tag: Application value: 'Connectivity unit information' - uuid: 42ebb179c4614d8d8c916c4285cb1891 name: 'Connectivity unit port info' type: SNMP_AGENT snmp_oid: 'discovery[{#CONNUNITPORTNAME}, 1.3.6.1.3.94.1.10.1.17]' key: connUnitPortName delay: 24h description: 'A user-defined name for this port. This means that up to DisplayString characters may be supported. If less than, then the name will be truncated in the connunit.' item_prototypes: - uuid: 969b295305f74e8fbedb1b5ca124c3e5 name: 'Connectivity unit port {#CONNUNITPORTNAME} state' type: SNMP_AGENT snmp_oid: '1.3.6.1.3.94.1.10.1.6.{#SNMPINDEX}' key: 'connUnitPortState[{#SNMPINDEX}]' delay: 5m description: 'The user selected state of the port hardware.' valuemap: name: HP2040ConnUnitPortState tags: - tag: Application value: 'Connectivity unit port information' trigger_prototypes: - uuid: 8f8f0997973a4f59af2c8f1fa50d3345 expression: 'last(/SNMP HP MSA 2040 SAN/connUnitPortState[{#SNMPINDEX}])<>2' name: 'Connectivity unit port {#CONNUNITPORTNAME} not in online state' priority: HIGH - uuid: ed3cb8e8438c4353a9e37534cbeee6c8 name: 'Connectivity unit port {#CONNUNITPORTNAME} status' type: SNMP_AGENT snmp_oid: '1.3.6.1.3.94.1.10.1.7.{#SNMPINDEX}' key: 'connUnitPortStatus[{#SNMPINDEX}]' delay: 5m description: 'An overall protocol status for the port. This value of connUnitPortState is not online, then this is reported Unknown.' valuemap: name: HP2040ConnUnitPortStatus tags: - tag: Application value: 'Connectivity unit port information' trigger_prototypes: - uuid: fb12add43457468296af1a05b3846a84 expression: 'last(/SNMP HP MSA 2040 SAN/connUnitPortStatus[{#SNMPINDEX}])=5' name: 'Connectivity unit port {#CONNUNITPORTNAME} have failure status' priority: HIGH - uuid: f214be6bf5e3494cad857431908a3919 expression: 'last(/SNMP HP MSA 2040 SAN/connUnitPortStatus[{#SNMPINDEX}])=1' name: 'Connectivity unit port {#CONNUNITPORTNAME} have unknown status' priority: HIGH - uuid: 496b26f2864540bc8d5446cd77557bcd expression: 'last(/SNMP HP MSA 2040 SAN/connUnitPortStatus[{#SNMPINDEX}])=4' name: 'Connectivity unit port {#CONNUNITPORTNAME} have warning status' priority: HIGH - uuid: 5a75a5aad92e450991b8070fd460974b name: 'Connectivity unit sensor info' type: SNMP_AGENT snmp_oid: 'discovery[{#CONNUNITSENSORNAME}, 1.3.6.1.3.94.1.8.1.3]' key: connUnitSensorName delay: 24h description: 'A textual identification of the sensor intended primarily for operator use.' item_prototypes: - uuid: 82ede73054b44b7f8cb665e083ad7157 name: 'Connectivity unit sensor {#CONNUNITSENSORNAME} status' type: SNMP_AGENT snmp_oid: '1.3.6.1.3.94.1.8.1.4.{#SNMPINDEX}' key: 'connUnitSensorStatus[{#SNMPINDEX}]' delay: 5m description: 'The status indicated by the sensor.' valuemap: name: HP2040ConnUnitStatus tags: - tag: Application value: 'Connectivity unit sensor information' trigger_prototypes: - uuid: 692b3ff7607a497a87661b5f7d05789e expression: 'last(/SNMP HP MSA 2040 SAN/connUnitSensorStatus[{#SNMPINDEX}])=5' name: 'Connectivity unit sensor {#CONNUNITSENSORNAME} have failed status' priority: HIGH - uuid: f83ee8f5bb5241fb94c89f98f502743c expression: 'last(/SNMP HP MSA 2040 SAN/connUnitSensorStatus[{#SNMPINDEX}])=2' name: 'Connectivity unit sensor {#CONNUNITSENSORNAME} have other status' priority: HIGH - uuid: 098bab0c7cde4ceaaca245e3ee70bea4 expression: 'last(/SNMP HP MSA 2040 SAN/connUnitSensorStatus[{#SNMPINDEX}])=1' name: 'Connectivity unit sensor {#CONNUNITSENSORNAME} have unknown status' priority: HIGH - uuid: a474af4f8e764dce9d1c944bac70f0a6 expression: 'last(/SNMP HP MSA 2040 SAN/connUnitSensorStatus[{#SNMPINDEX}])=4' name: 'Connectivity unit sensor {#CONNUNITSENSORNAME} have warning status' priority: HIGH valuemaps: - uuid: 8b66865c5fed4d44a6de07fc2486be19 name: HP2040ConnUnitPortState mappings: - value: '1' newvalue: unknown - value: '2' newvalue: online - value: '3' newvalue: offline - value: '4' newvalue: bypassed - value: '5' newvalue: diagnostics - uuid: 6db878dd518940079082e23be57d9837 name: HP2040ConnUnitPortStatus mappings: - value: '1' newvalue: unknown - value: '2' newvalue: unused - value: '3' newvalue: ready - value: '4' newvalue: warning - value: '5' newvalue: failure - value: '6' newvalue: notparticipating - value: '7' newvalue: initializing - value: '8' newvalue: bypass - value: '9' newvalue: ols - value: '10' newvalue: other - uuid: 3a1668d44fbf424f89746de74ac42c9a name: HP2040ConnUnitState mappings: - value: '1' newvalue: unknown - value: '2' newvalue: online - value: '3' newvalue: offline - uuid: 29ac210b384144db9e2fc7d52ec0f011 name: HP2040ConnUnitStatus mappings: - value: '1' newvalue: unknown - value: '2' newvalue: unused - value: '3' newvalue: ok - value: '4' newvalue: warning - value: '5' newvalue: failed - uuid: d4fb102284884235b23ef5ddff13a075 name: HP2040ConnUnitType mappings: - value: '1' newvalue: unknown - value: '2' newvalue: other - value: '3' newvalue: hub - value: '4' newvalue: switch - value: '5' newvalue: gateway - value: '6' newvalue: converter - value: '7' newvalue: hba - value: '8' newvalue: proxy-agent - value: '9' newvalue: storage-device - value: '10' newvalue: host - value: '11' newvalue: storage-subsystem - value: '12' newvalue: module - value: '13' newvalue: swdriver - value: '14' newvalue: storage-access-device - value: '15' newvalue: wdm - value: '16' newvalue: ups - value: '17' newvalue: nas