zabbix_export: version: '5.4' date: '2021-11-21T22:04:19Z' groups: - uuid: 7df96b18c230490a9a0a9e2307226338 name: Templates templates: - uuid: cd99dc4d6c2840998746676ec12bc33e template: 'Power Supply NetEngine SNMP' name: 'Power Supply NetEngine SNMP' description: | ## Overview Monitoramento de PSU linha NetEngine... Testado com NE40 e NE20 ## Author carlosviatroski groups: - name: Templates items: - uuid: 69fdebfa65584b069bf247b8c864f366 name: 'Corrente Fonte A' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.2011.5.25.31.1.1.18.1.7.4.0 key: hwEntityPwrCurrent.A delay: 3m value_type: FLOAT units: A description: 'Este objeto indica a corrente da energia. Unidade: mA' preprocessing: - type: MULTIPLIER parameters: - '0.001' tags: - tag: Application value: 'Power Supply' - uuid: 7a4e5e4ee77f4062b57256e1c71d5905 name: 'Corrente Fonte B' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.2011.5.25.31.1.1.18.1.7.5.0 key: hwEntityPwrCurrent.B delay: 3m value_type: FLOAT units: A description: 'Este objeto indica a corrente da energia. Unidade: mA' preprocessing: - type: MULTIPLIER parameters: - '0.001' tags: - tag: Application value: 'Power Supply' - uuid: ec549b766abb4deaa26180bdd7502a3a name: 'Energia Fonte A' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.2011.5.25.31.1.1.18.1.5.5.0 key: hwEntityPwrPresent.A delay: 3m description: 'Presença de energia na fonte A' tags: - tag: Application value: 'Power Supply' triggers: - uuid: 053cc175c122423189c4e03b7f29bc3e expression: 'last(/Power Supply NetEngine SNMP/hwEntityPwrPresent.A)=0' recovery_mode: RECOVERY_EXPRESSION recovery_expression: 'last(/Power Supply NetEngine SNMP/hwEntityPwrPresent.A)=1' name: 'Falha de Energia na Fonte A' priority: HIGH manual_close: 'YES' - uuid: 47b64dcf8fe1449bb7d196a5ffbc8506 name: 'Energia Fonte B' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.2011.5.25.31.1.1.18.1.5.5.0 key: hwEntityPwrPresent.B delay: 3m description: 'Presença de energia na fonte B' tags: - tag: Application value: 'Power Supply' triggers: - uuid: 654b0dea83a74e9191e61d5118be2ca4 expression: 'last(/Power Supply NetEngine SNMP/hwEntityPwrPresent.B)=0' recovery_mode: RECOVERY_EXPRESSION recovery_expression: 'last(/Power Supply NetEngine SNMP/hwEntityPwrPresent.B)=1' name: 'Falha de Energia na Fonte B' priority: HIGH manual_close: 'YES' - uuid: e05e9654c86d4e2f86fe3f5a8289ba5e name: 'Estado da Energia Fonte A' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.2011.5.25.31.1.1.18.1.6.4.0 key: hwEntityPwrState.A delay: 3m description: 'Status da energia na fonte A' tags: - tag: Application value: 'Power Supply' - uuid: 76a330995c194286bed1730292a685af name: 'Estado da Energia Fonte B' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.2011.5.25.31.1.1.18.1.6.5.0 key: hwEntityPwrState.B delay: 3m description: 'Status da energia na fonte B' tags: - tag: Application value: 'Power Supply' - uuid: a8437cda013246a1ac9b9c4327533b05 name: 'Voltagem Fonte A' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.2011.5.25.31.1.1.18.1.8.4.0 key: hwEntityPwrVoltage.A delay: 3m value_type: FLOAT units: V description: 'Este objeto indica a voltagem da energia. Unidade: mV' preprocessing: - type: MULTIPLIER parameters: - '0.001' tags: - tag: Application value: 'Power Supply' - uuid: a452a591f4974c3abffe7de2e60d3009 name: 'Voltagem Fonte B' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.2011.5.25.31.1.1.18.1.8.5.0 key: hwEntityPwrVoltage.B delay: 3m value_type: FLOAT units: V description: 'Este objeto indica a voltagem da energia. Unidade: mV' preprocessing: - type: MULTIPLIER parameters: - '0.001' tags: - tag: Application value: 'Power Supply'