zabbix_export: version: '6.0' date: '2021-11-21T22:04:23Z' groups: - uuid: 7df96b18c230490a9a0a9e2307226338 name: Templates templates: - uuid: a1004edc72c1494da81c4bc45c74ac70 template: 'Power Supply S6700 SNMP' name: 'Power Supply S6700 SNMP' description: | ## Overview Regra de Descoberta com Filtros para monitoramento de PSU na linha S6700.. Testado com S6720, S5720, S6730, S5732 ## Author carlosviatroski groups: - name: Templates discovery_rules: - uuid: 69984267ee224c35b723fa98e8c3a411 name: 'Power Supply Status' type: SNMP_AGENT snmp_oid: 'discovery[{#ENT_NAME},1.3.6.1.2.1.47.1.1.1.1.7]' key: hwPowerSupplyStatus delay: 1d filter: evaltype: OR conditions: - macro: '{#ENT_NAME}' value: '.*PWR' formulaid: A item_prototypes: - uuid: fb32e611399841d79ac26d9b91319716 name: 'Status Power Supply' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.2011.5.25.31.1.1.1.1.2.{#SNMPINDEX}' key: 'Status[hwPowerSupplyStatus.{#ENT_NAME}]' delay: 3m tags: - tag: Application value: 'Power Supply' trigger_prototypes: - uuid: 76600f9967564e7cb50d297119450804 expression: 'last(/Power Supply S6700 SNMP/Status[hwPowerSupplyStatus.{#ENT_NAME}])=2' recovery_mode: RECOVERY_EXPRESSION recovery_expression: 'last(/Power Supply S6700 SNMP/Status[hwPowerSupplyStatus.{#ENT_NAME}])=3' name: 'Problema no Slot {#ENT_NAME}' priority: HIGH manual_close: 'YES'