5.02021-11-21T21:37:48ZZBX-INFINERA-TEMPLATESZBX-INFINERA-XTM-SERIES-MONITORINGZBX-INFINERA-XTM-SERIES-MONITORING## Overview
README: <https://github.com/hacktivism-github/zbx-templates-repository/blob/master/zbx-infinera/README.md>
![Infinera XTM Series Template in Production](media/com_mtree/images/listings/m/481.png)
## Author
Bruno Teixeira
ZBX-INFINERA-TEMPLATESXTM Series::Client InterfacesXTM Series::Equipment StatusXTM Series::Metro Ethernet Services infoXTM Series::Optical AmplifiersXTM Series::Optical Supervisory ChannelXTM Series::Performance Measurement- XTM Series | Unsaved Changes AlarmSNMP_AGENTLUM-BACKUP-MIB::backupGeneralUnsavedChangesAlarm.0backupGeneralUnsavedChangesAlarm30014d0CHARTM-3000/II Chassis | GENERIC for 1(ok) 2 (alarm) cases{last(#1)}<>1[10.007] Configuration has not been savedINFO
XTM Series::Client Interfaces::EMXPxxxSNMP_AGENTdiscovery[{#SNMPVALUE},clientIfName]clientIfName30014dXTM Series | clientIfAdminStatus $1SNMP_AGENTLUM-CLIENT-MIB::clientIfAdminStatus.{#SNMPINDEX}clientIfAdminStatus[{#SNMPVALUE}]30014d0CHARXTM Series::Client InterfacesXTM Series | clientIfAdminStatusXTM Series | Description on interface $1SNMP_AGENTLUM-CLIENT-MIB::clientIfDescr.{#SNMPINDEX}clientIfDescr[{#SNMPVALUE}]3000TEXTXTM Series::Client InterfacesTM-3000/II Chassis | clientIfLossOfSignal $1SNMP_AGENTLUM-CLIENT-MIB::clientIfLossOfSignal.{#SNMPINDEX}clientIfLossOfSignal[{#SNMPVALUE}]30014d0CHARXTM Series::Client InterfacesTM-3000/II Chassis | GENERIC for 1(ok) 2 (alarm) casesTM-3000/II Chassis | clientIfName $1SNMP_AGENTLUM-CLIENT-MIB::clientIfName.{#SNMPINDEX}clientIfName[{#SNMPVALUE}]30014d0CHARXTM Series::Client InterfacesXTM Series | clientIfOperStatus $1SNMP_AGENTLUM-CLIENT-MIB::clientIfAdminStatus.{#SNMPINDEX}clientIfOperStatus[{#SNMPVALUE}]3000CHARXTM Series::Client InterfacesTM-3000/II Chassis | GENERIC 1(notPresent) 2(down) & 3(up) casesXTM Series | clientIfPowerLevelLowRelativeThreshold $1SNMP_AGENTLUM-CLIENT-MIB::clientIfPowerLevelLowRelativeThreshold.{#SNMPINDEX}clientIfPowerLevelLowRelativeThreshold[{#SNMPVALUE}]30014dFLOATdBmXTM Series::Client InterfacesMULTIPLIER0.1XTM Series | clientIfPowerLevel $1SNMP_AGENTLUM-CLIENT-MIB::clientIfPowerLevel.{#SNMPINDEX}clientIfPowerLevel[{#SNMPVALUE}]300FLOATdBmXTM Series::Client InterfacesMULTIPLIER0.1{last(#1)}>=-10[10.002] High Rx Optical Power on {#SNMPVALUE}DISABLEDHIGH{last(#1)}<=-9[10.002] Low Rx Optical Power on {#SNMPVALUE}DISABLEDWARNINGTM-3000/II Chassis | clientIfReceivedPowerHigh $1SNMP_AGENTLUM-CLIENT-MIB::clientIfReceivedPowerHigh.{#SNMPINDEX}clientIfReceivedPowerHigh[{#SNMPVALUE}]30014d0CHARXTM Series::Client InterfacesTM-3000/II Chassis | GENERIC for 1(ok) 2 (alarm) casesTM-3000/II Chassis | clientIfReceivedPowerLow on $1SNMP_AGENTLUM-CLIENT-MIB::clientIfReceivedPowerLow.{#SNMPINDEX}clientIfReceivedPowerLow[{#SNMPVALUE}]30014d0CHARXTM Series::Client InterfacesTM-3000/II Chassis | GENERIC for 1(ok) 2 (alarm) casesXTM Series | clientIfReceiverSensitivity $1SNMP_AGENTLUM-CLIENT-MIB::clientIfReceiverSensitivity.{#SNMPINDEX}clientIfReceiverSensitivity[{#SNMPVALUE}]30014dFLOATdBmLUM-CLIENT-MIB::clientIfReceiverSensitivity
The lowest power that the receiver is guaranteed to handle, in units of 0.1 dBm.XTM Series::Client InterfacesMULTIPLIER0.1XTM Series | clientIfRxSignalStatus $1SNMP_AGENTLUM-CLIENT-MIB::clientIfRxSignalStatus.{#SNMPINDEX}clientIfRxSignalStatus[{#SNMPVALUE}]30014d0CHARXTM Series::Client InterfacesXTM Series | clientIfRxSignalStatus{ZBX-INFINERA-XTM-SERIES-MONITORING:clientIfReceivedPowerLow[{#SNMPVALUE}].last(#1)}<>1 and {ZBX-INFINERA-XTM-SERIES-MONITORING:clientIfDescr[{#SNMPVALUE}].str(this_does_not_exist)}=0[10.002] EMXP240/IIE | Low Rx Optical Power on {#SNMPVALUE} : {ITEM.VALUE2}WARNING{ZBX-INFINERA-XTM-SERIES-MONITORING:clientIfLossOfSignal[{#SNMPVALUE}].last(#1)}<>1 and {ZBX-INFINERA-XTM-SERIES-MONITORING:clientIfDescr[{#SNMPVALUE}].str(this_does_not_exist)}=0[10.003] EMXP240/IIE | Loss of Signal on {#SNMPVALUE} : {ITEM.VALUE2}HIGHclientIfPowerLevel on: {#SNMPVALUE} | {{HOSTNAME}:clientIfName[{#SNMPVALUE}].last(0)}BOLD_LINEFF3333- ZBX-INFINERA-XTM-SERIES-MONITORINGclientIfPowerLevelLowRelativeThreshold[{#SNMPVALUE}]
1BOLD_LINE1A7C11- ZBX-INFINERA-XTM-SERIES-MONITORINGclientIfPowerLevel[{#SNMPVALUE}]
2BOLD_LINE2774A4- ZBX-INFINERA-XTM-SERIES-MONITORINGclientIfReceiverSensitivity[{#SNMPVALUE}]
XTM Series::DCN::CU SFP/II::Optical Supervisory ChannelSNMP_AGENTdiscovery[{#SNMPVALUE},dcnIfName]dcnIfName30014dTM-3000/II Chassis | CU SFP/II | dcnIfDescr $1SNMP_AGENTLUM-DCN-MIB::dcnIfDescr.{#SNMPINDEX}dcnIfDescr[{#SNMPVALUE}]360014d0TEXTXTM Series::Optical Supervisory ChannelTM-3000/II Chassis | CU SFP/II | dcnIfName $1SNMP_AGENTLUM-DCN-MIB::dcnIfName.{#SNMPINDEX}dcnIfName[{#SNMPVALUE}]360014d0CHARXTM Series::Optical Supervisory ChannelTM-3000/II Chassis | CU SFP/II | dcnIfOperStatus $1SNMP_AGENTLUM-DCN-MIB::dcnIfOperStatus.{#SNMPINDEX}dcnIfOperStatus[{#SNMPVALUE}]30014d0CHARXTM Series::Optical Supervisory ChannelTM-3000/II Chassis | GENERIC 1(notPresent) 2(down) & 3(up) casesTM-3000/II Chassis | CU SFP/II | dcnIfPowerLevel $1SNMP_AGENTLUM-DCN-MIB::dcnIfPowerLevel.{#SNMPINDEX}dcnIfPowerLevel[{#SNMPVALUE}]30014dFLOATdBmXTM Series::Optical Supervisory ChannelMULTIPLIER0.1TM-3000/II Chassis | CU SFP/II | dcnIfReceivedPowerHigh $1SNMP_AGENTLUM-DCN-MIB::dcnIfReceivedPowerHigh.{#SNMPINDEX}dcnIfReceivedPowerHigh[{#SNMPVALUE}]30014d0CHARXTM Series::Optical Supervisory ChannelTM-3000/II Chassis | GENERIC for 1(ok) 2 (alarm) casesTM-3000/II Chassis | CU SFP/II | dcnIfReceivedPowerLow $1SNMP_AGENTLUM-DCN-MIB::dcnIfReceivedPowerLow .{#SNMPINDEX}dcnIfReceivedPowerLow[{#SNMPVALUE}]30014d0CHARXTM Series::Optical Supervisory ChannelTM-3000/II Chassis | GENERIC for 1(ok) 2 (alarm) cases{ZBX-INFINERA-XTM-SERIES-MONITORING:dcnIfReceivedPowerHigh[{#SNMPVALUE}].last(#1)}<>1 and
{ZBX-INFINERA-XTM-SERIES-MONITORING:dcnIfDescr[{#SNMPVALUE}].str(this_does_not_exist)}=0[10.002] CU SFP/II | High Rx Optical Power on {#SNMPVALUE} : {ITEM.VALUE2}HIGH{ZBX-INFINERA-XTM-SERIES-MONITORING:dcnIfReceivedPowerLow[{#SNMPVALUE}].last(#1)}<>1 and
{ZBX-INFINERA-XTM-SERIES-MONITORING:dcnIfDescr[{#SNMPVALUE}].str(this_does_not_exist)}=0[10.002] CU SFP/II | Low Rx Optical Power on {#SNMPVALUE} : {ITEM.VALUE2}WARNINGTM-3000/II Chassis | CU SFP/II | dcnIfPowerLevel on {#SNMPVALUE}BOLD_LINE1A7C11- ZBX-INFINERA-XTM-SERIES-MONITORINGdcnIfPowerLevel[{#SNMPVALUE}]
XTM Series::Equipment Status::Board Configuration and StatusSNMP_AGENTdiscovery[{#SNMPVALUE},equipmentBoardName]equipmentBoardName30014dXTM Series | CU-SFP/II | Communication Failure on $1SNMP_AGENTLUM-EQUIPMENT-MIB::equipmentBoardCommunicationFailure.{#SNMPINDEX}equipmentBoardCommunicationFailure[{#SNMPVALUE}]30014d0CHARXTM Series::Equipment StatusTM-3000/II Chassis | GENERIC for 1(ok) 2 (alarm) cases{last(#1)}<>1[] CU SFP/II Communication Failure with {#SNMPVALUE}HIGHXTM Series | equipmentBoardName $1SNMP_AGENTLUM-EQUIPMENT-MIB::equipmentBoardName.{#SNMPINDEX}equipmentBoardName[{#SNMPVALUE}]864007d0CHARXTM Series::Equipment StatusXTM Series | equipmentBoardOperStatus $1SNMP_AGENTLUM-EQUIPMENT-MIB::equipmentBoardOperStatus.{#SNMPINDEX}equipmentBoardOperStatus[{#SNMPVALUE}]30014d0CHARXTM Series::Equipment StatusTM-3000/II Chassis | GENERIC 1(notPresent) 2(down) & 3(up) casesXTM Series | Secondary DC Power Failed on $1SNMP_AGENTLUM-EQUIPMENT-MIB::equipmentBoardSecondaryPowerFailed.{#SNMPINDEX}equipmentBoardSecondaryPowerFailed[{#SNMPVALUE}]30014d0CHARXTM Series::Equipment StatusTM-3000/II Chassis | GENERIC for 1(ok) 2 (alarm) cases{last(#1)}<>1[] Secondary DC Power Failed on {#SNMPVALUE}HIGHXTM Series | High Board Temperature on $1SNMP_AGENTLUM-EQUIPMENT-MIB::equipmentBoardTempHighExceeded.{#SNMPINDEX}equipmentBoardTempHighExceeded[{#SNMPVALUE}]30014d0CHARXTM Series::Equipment StatusTM-3000/II Chassis | GENERIC for 1(ok) 2 (alarm) cases{last(#1)}<>1[] High Board Temperature on {#SNMPVALUE}HIGHXTM Series | Equipment Board Temp Low Threshold on $1SNMP_AGENTLUM-EQUIPMENT-MIB::equipmentBoardTempLowThreshold.{#SNMPINDEX}equipmentBoardTempLowThreshold[{#SNMPVALUE}]30014dFLOATdegCXTM Series::Equipment StatusMULTIPLIER0.1XTM Series | Equipment Board Temp Low on $1SNMP_AGENTLUM-EQUIPMENT-MIB::equipmentBoardTempLow.{#SNMPINDEX}equipmentBoardTempLow[{#SNMPVALUE}]30014dFLOATdegCXTM Series::Equipment StatusMULTIPLIER0.1XTM Series | Equipment Board Temp Threshold on $1SNMP_AGENTLUM-EQUIPMENT-MIB::equipmentBoardTempThreshold.{#SNMPINDEX}equipmentBoardTempThreshold[{#SNMPVALUE}]30014dFLOATdegCXTM Series::Equipment StatusMULTIPLIER0.1XTM Series | Equipment Board Temp Very High on $1SNMP_AGENTLUM-EQUIPMENT-MIB::equipmentBoardTempVeryHigh.{#SNMPINDEX}equipmentBoardTempVeryHigh[{#SNMPVALUE}]30014d0CHARXTM Series::Equipment StatusTM-3000/II Chassis | GENERIC for 1(ok) 2 (alarm) cases{last(#1)}<>1[] Equipment Board Temperature Very High on {#SNMPVALUE}WARNINGXTM Series | equipmentBoardUnderMaintenance $1SNMP_AGENTLUM-EQUIPMENT-MIB::equipmentBoardUnderMaintenance.{#SNMPINDEX}equipmentBoardUnderMaintenance[{#SNMPVALUE}]30014d0CHARXTM Series::Equipment StatusTM-3000/II Chassis | GENERIC for 1(ok) 2 (alarm) cases{last(#1)}<>1[10.004] Board Under Maintenance {#SNMPVALUE}INFOXTM Series::Equipment Status::Fan statusSNMP_AGENTdiscovery[{#SNMPVALUE},equipmentFanName]equipmentFanName30014dXTM Series | equipmentFanName $1SNMP_AGENTLUM-EQUIPMENT-MIB::equipmentFanName.{#SNMPINDEX}equipmentFanName[{#SNMPVALUE}]864007d0CHARXTM Series::Equipment StatusXTM Series | equipmentFanOperStatus $1SNMP_AGENTLUM-EQUIPMENT-MIB::equipmentFanOperStatus.{#SNMPINDEX}equipmentFanOperStatus[{#SNMPVALUE}]30014d0CHARXTM Series::Equipment StatusTM-3000/II Chassis | GENERIC 1(notPresent) 2(down) & 3(up) casesXTM Series | equipmentFanUnitFailed $1SNMP_AGENTLUM-EQUIPMENT-MIB::equipmentFanUnitFailed.{#SNMPINDEX}equipmentFanUnitFailed[{#SNMPVALUE}]30014d0CHARXTM Series::Equipment StatusTM-3000/II Chassis | GENERIC for 1(ok) 2 (alarm) cases{last(#1)}<>1[02.009] {#SNMPVALUE} Fan Unit FailedWARNINGXTM Series::Equipment Status::Power Supply StatusSNMP_AGENTdiscovery[{#SNMPVALUE},equipmentPowerName]equipmentPowerName30014dXTM Series | equipmentPowerDCPowerFailedSeverity $1SNMP_AGENTLUM-EQUIPMENT-MIB::equipmentPowerDCPowerFailedSeverity.{#SNMPINDEX}equipmentPowerDCPowerFailedSeverity[{#SNMPVALUE}]30014d0CHARXTM Series::Equipment StatusTM-3000/II Chassis | equipmentPowerDCPowerFailedXTM Series | equipmentPowerDCPowerFailed $1SNMP_AGENTLUM-EQUIPMENT-MIB::equipmentPowerDCPowerFailed.{#SNMPINDEX}equipmentPowerDCPowerFailed[{#SNMPVALUE}]30014d0CHARXTM Series::Equipment StatusTM-3000/II Chassis | GENERIC for 1(ok) 2 (alarm) cases{last(#1)}<>1[04.104] {#SNMPVALUE} DC Power Supply FailedHIGHXTM Series | equipmentPowerName $1SNMP_AGENTLUM-EQUIPMENT-MIB::equipmentPowerName.{#SNMPINDEX}equipmentPowerName[{#SNMPVALUE}]864007d0CHARXTM Series::Equipment StatusXTM Series | equipmentPowerOperStatus $1SNMP_AGENTLUM-EQUIPMENT-MIB::equipmentPowerOperStatus.{#SNMPINDEX}equipmentPowerOperStatus[{#SNMPVALUE}]30014d0CHARXTM Series::Equipment StatusTM-3000/II Chassis | GENERIC 1(notPresent) 2(down) & 3(up) casesXTM Series | equipmentPowerType $1SNMP_AGENTLUM-EQUIPMENT-MIB::equipmentPowerType.{#SNMPINDEX}equipmentPowerType[{#SNMPVALUE}]864007d0CHARXTM Series::Equipment StatusTM-3000/II Chassis | equipmentPowerTypeXTM Series::Equipment Status::Subrack StatusSNMP_AGENTdiscovery[{#SNMPVALUE},equipmentSubrackName]equipmentSubrackName30014dXTM Series | equipmentSubrackName $1SNMP_AGENTLUM-EQUIPMENT-MIB::equipmentSubrackName.{#SNMPINDEX}equipmentSubrackName[{#SNMPVALUE}]864007d0CHARXTM Series::Equipment StatusXTM Series | equipmentSubrackOperStatus on $1SNMP_AGENTLUM-EQUIPMENT-MIB::equipmentSubrackOperStatus.{#SNMPINDEX}equipmentSubrackOperStatus[{#SNMPVALUE}]30014d0CHARXTM Series::Equipment StatusTM-3000/II Chassis | GENERIC 1(notPresent) 2(down) & 3(up) casesXTM Series | equipmentSubrackTempHighExceeded on $1SNMP_AGENTLUM-EQUIPMENT-MIB::equipmentSubrackTempHighExceeded.{#SNMPINDEX}equipmentSubrackTempHighExceeded[{#SNMPVALUE}]30014d0CHARXTM Series::Equipment StatusTM-3000/II Chassis | GENERIC for 1(ok) 2 (alarm) cases{last(#1)}<>1[02.010] High Subrack Temperature $1WARNINGXTM Series | Equipment Subrack Temperature Threshold on $1SNMP_AGENTLUM-EQUIPMENT-MIB::equipmentSubrackTempThreshold.{#SNMPINDEX}equipmentSubrackTempThreshold[{#SNMPVALUE}]30014ddegCXTM Series::Equipment StatusMULTIPLIER0.1XTM Series | Equipment Subrack Temperature on $1SNMP_AGENTLUM-EQUIPMENT-MIB::equipmentSubrackTemp.{#SNMPINDEX}equipmentSubrackTemp[{#SNMPVALUE}]30014ddegCXTM Series::Equipment StatusMULTIPLIER0.1XTM Series::Metro Ethernet ServicesSNMP_AGENTdiscovery[{#SNMPVALUE},mesErrorPropName]mesErrorPropName3014dXTM Series | MES Error Propagation Fault on $1SNMP_AGENTLUM-MES-MIB::mesErrorPropFault.{#SNMPINDEX}mesErrorPropFault[{#SNMPVALUE}]30014d0CHARXTM Series::Metro Ethernet Services infoTM-3000/II Chassis | GENERIC for 1(ok) 2 (alarm) cases{last(#1)}<>1[10.005] EMXP240/IIE | Error Propagation Active on {#SNMPVALUE}WARNINGXTM Series::Optical AmplifiersSNMP_AGENTdiscovery[{#SNMPVALUE},oaIfName]oaIfName30014dXTM Series | OA Adminintrative State for the interface $1SNMP_AGENTLUM-OA-MIB::oaIfAdminStatus.{#SNMPINDEX}oaIfAdminStatus[{#SNMPVALUE}]30014d0CHARXTM Series::Optical AmplifiersXTM Series | clientIfAdminStatusXTM Series | OA interface Description for $1SNMP_AGENTLUM-OA-MIB::oaIfDescr.{#SNMPINDEX}oaIfDescr[{#SNMPVALUE}]30014d0TEXTXTM Series::Optical AmplifiersXTM Series | OA Laser Bias High on $1SNMP_AGENTLUM-OA-MIB::oaIfLaserBiasHigh.{#SNMPINDEX}oaIfLaserBiasHigh[{#SNMPVALUE}]30014d0CHARXTM Series::Optical AmplifiersTM-3000/II Chassis | GENERIC for 1(ok) 2 (alarm) cases{last(#1)}<>1[] OA High Laser Bias on {#SNMPVALUE}INFOXTM Series | OA Loss Of Signal on $1SNMP_AGENTLUM-OA-MIB::oaIfLossOfSignal.{#SNMPINDEX}oaIfLossOfSignal[{#SNMPVALUE}]30014d0CHARXTM Series::Optical AmplifiersTM-3000/II Chassis | GENERIC for 1(ok) 2 (alarm) casesXTM Series | OA interface $1SNMP_AGENTLUM-OA-MIB::oaIfName.me.{#SNMPINDEX}oaIfName.me[{#SNMPVALUE}]30014d0CHARXTM Series::Optical AmplifiersXTM Series | OA Operational State for the interface $1SNMP_AGENTLUM-OA-MIB::oaIfOperStatus.{#SNMPINDEX}oaIfOperStatus[{#SNMPVALUE}]30014d0CHARXTM Series::Optical AmplifiersTM-3000/II Chassis | GENERIC 1(notPresent) 2(down) & 3(up) cases{last(#1)}<>3[] OA interface {#SNMPVALUE} changed its Operational state to DOWNHIGHXTM Series | OA Output Power Fail on $1SNMP_AGENTLUM-OA-MIB::oaIfOutputPowerFail.{#SNMPINDEX}oaIfOutputPowerFail[{#SNMPVALUE}]30014d0CHARXTM Series::Optical Amplifiers{last(#1)}<>1[] OA Output power failed on {#SNMPVALUE}HIGHXTM Series | OA Pump Laser Temp Low on $1SNMP_AGENTLUM-OA-MIB::oaIfPumpLaserTempLow.{#SNMPINDEX}oaIfPumpLaserTempLow[{#SNMPVALUE}]30014d0CHARXTM Series::Optical AmplifiersTM-3000/II Chassis | GENERIC for 1(ok) 2 (alarm) cases{last(#1)}<>1[] OA Pump Laser Temp Low on {#SNMPVALUE}WARNINGXTM Series | OA Received Power Low on $1SNMP_AGENTLUM-OA-MIB::oaIfReceivedPowerLow.{#SNMPINDEX}oaIfReceivedPowerLow[{#SNMPVALUE}]30014d0CHARXTM Series::Optical AmplifiersTM-3000/II Chassis | GENERIC for 1(ok) 2 (alarm) cases{last(#1)}<>1[10.006] OA Low Received Optical Power on {#SNMPVALUE}WARNINGXTM Series | OA Rx Power Level Low Threshold on $1SNMP_AGENTLUM-OA-MIB::oaIfRxPowerLevelLowThreshold.{#SNMPINDEX}oaIfRxPowerLevelLowThreshold[{#SNMPVALUE}]30014dFLOATdBXTM Series::Optical AmplifiersMULTIPLIER0.1XTM Series | OA Rx power level on $1SNMP_AGENTLUM-OA-MIB::oaIfRxPowerLevel.{#SNMPINDEX}oaIfRxPowerLevel[{#SNMPVALUE}]30014dFLOATdBXTM Series::Optical AmplifiersMULTIPLIER0.1XTM Series | OA Saturation Fault on $1SNMP_AGENTLUM-OA-MIB::oaIfSaturationFault.{#SNMPINDEX}oaIfSaturationFault[{#SNMPVALUE}]30014d0CHARXTM Series::Optical AmplifiersTM-3000/II Chassis | GENERIC for 1(ok) 2 (alarm) cases{last(#1)}<>1[] OA Amplifier Saturation alarm on {#SNMPVALUE}INFOXTM Series | OA Tx Power Level Low Threshold on $1SNMP_AGENTLUM-OA-MIB::oaIfTxPowerLevelLowThreshold.{#SNMPINDEX}oaIfTxPowerLevelLowThreshold[{#SNMPVALUE}]30014dFLOATdBXTM Series::Optical AmplifiersMULTIPLIER0.1XTM Series | OA Tx power level on $1SNMP_AGENTLUM-OA-MIB::oaIfTxPowerLevel.{#SNMPINDEX}oaIfTxPowerLevel[{#SNMPVALUE}]30014dFLOATdBXTM Series::Optical AmplifiersMULTIPLIER0.1{ZBX-INFINERA-XTM-SERIES-MONITORING:oaIfLossOfSignal[{#SNMPVALUE}].last(#1)}<>1 and {ZBX-INFINERA-XTM-SERIES-MONITORING:oaIfDescr[{#SNMPVALUE}].str(this_does_not_exist)}=0[10.003] OA2 LG 20/20C | Loss of Signal on interface {#SNMPVALUE} : {ITEM.VALUE2}HIGHOA Rx/Tx Power Levels and Thresholds on: {#SNMPVALUE}BOLD_LINE1A7C11- ZBX-INFINERA-XTM-SERIES-MONITORINGoaIfRxPowerLevel[{#SNMPVALUE}]
1BOLD_LINE3333FF- ZBX-INFINERA-XTM-SERIES-MONITORINGoaIfTxPowerLevel[{#SNMPVALUE}]
2BOLD_LINEFF3333- ZBX-INFINERA-XTM-SERIES-MONITORINGoaIfRxPowerLevelLowThreshold[{#SNMPVALUE}]
3BOLD_LINEFF8000- ZBX-INFINERA-XTM-SERIES-MONITORINGoaIfTxPowerLevelLowThreshold[{#SNMPVALUE}]
XTM Series::PM EthTD::Current Meters and ConfigurationSNMP_AGENTdiscovery[{#SNMPVALUE},pmEthTdName]pmEthTdName300XTM Series | Rx Ethernet Traffic Data on $1SNMP_AGENTLUM-PM-MIB::pmEthTdCurrentContRxOctets.{#SNMPINDEX}pmEthTdCurrentContRxOctets[{#SNMPVALUE}]30014dbpsXTM Series::Performance MeasurementCHANGE_PER_SECONDMULTIPLIER8XTM Series | Tx Ethernet Traffic Data on $1SNMP_AGENTLUM-PM-MIB::pmEthTdCurrentContTxOctets.{#SNMPINDEX}pmEthTdCurrentContTxOctets[{#SNMPVALUE}]30014dbpsXTM Series::Performance MeasurementCHANGE_PER_SECONDMULTIPLIER8XTM Series | pmEthTdName $1SNMP_AGENTLUM-PM-MIB::pmEthTdName.{#SNMPINDEX}pmEthTdName[{#SNMPVALUE}]30014d0CHARXTM Series::Performance MeasurementRx/Tx Ethernet Traffic Data on: {#SNMPVALUE}BOLD_LINE1A7C11- ZBX-INFINERA-XTM-SERIES-MONITORINGpmEthTdCurrentContRxOctets[{#SNMPVALUE}]
1BOLD_LINEF63100- ZBX-INFINERA-XTM-SERIES-MONITORINGpmEthTdCurrentContTxOctets[{#SNMPVALUE}]
XTM Series::PM Rx/Tx Power Levels::Current Meters and ConfigurationSNMP_AGENTdiscovery[{#SNMPVALUE},pmIfName]pmIfName30014dXTM Series | pmIfAdminStatus $1SNMP_AGENTLUM-PM-MIB::pmIfAdminStatus.{#SNMPINDEX}pmIfAdminStatus[{#SNMPVALUE}]30014d0CHARXTM Series::Performance MeasurementTM-3000/II Chassis | pmIfAdminStatusXTM Series | pmIfName $1SNMP_AGENTLUM-PM-MIB::pmIfName.{#SNMPINDEX}pmIfName[{#SNMPVALUE}]30014d0CHARXTM Series::Performance MeasurementXTM Series | pmIfOperStatus $1SNMP_AGENTLUM-PM-MIB::pmIfOperStatus.{#SNMPINDEX}pmIfOperStatus[{#SNMPVALUE}]30014d0CHARXTM Series::Performance MeasurementTM-3000/II Chassis | GENERIC 1(notPresent) 2(down) & 3(up) casesXTM Series | pmIfRx24hCurrentUAS on $1SNMP_AGENTLUM-PM-MIB::pmIfRx24hCurrentUAS.{#SNMPINDEX}pmIfRx24hCurrentUAS[{#SNMPVALUE}]30014dDISABLEDsXTM Series::Performance Measurement{last(#1)}>300UAS Rx 24 hour Threshold Exceeded on {#SNMPVALUE}DISABLEDWARNINGXTM Series | pmIfRx24hUASThreshold on $1SNMP_AGENTLUM-PM-MIB::pmIfRx24hUASThreshold.{#SNMPINDEX}pmIfRx24hUASThreshold[{#SNMPVALUE}]30014dDISABLEDsXTM Series::Performance MeasurementXTM Series | pmIfRx24hUAS on $1SNMP_AGENTLUM-PM-MIB::pmIfRx24hUAS.{#SNMPINDEX}pmIfRx24hUAS[{#SNMPVALUE}]30014d0DISABLEDCHARXTM Series::Performance MeasurementTM-3000/II Chassis | GENERIC for 1(ok) 2 (alarm) casesXTM Series | Rx Power Level on $1SNMP_AGENTLUM-PM-MIB::pmIfRxPowerLevel.{#SNMPINDEX}pmIfRxPowerLevel[{#SNMPVALUE}]30014dFLOATdBmXTM Series::Performance MeasurementMULTIPLIER0.1XTM Series | pmIfTx24hCurrentUAS on $1SNMP_AGENTLUM-PM-MIB::pmIfTx24hCurrentUAS.{#SNMPINDEX}pmIfTx24hCurrentUAS[{#SNMPVALUE}]300DISABLEDsXTM Series::Performance MeasurementXTM Series | pmIfTx24hUASThreshold on $1SNMP_AGENTLUM-PM-MIB::pmIfTx24hUASThreshold.{#SNMPINDEX}pmIfTx24hUASThreshold[{#SNMPVALUE}]30014dDISABLEDsXTM Series::Performance MeasurementXTM Series | pmIfTx24hUAS on $1SNMP_AGENTLUM-PM-MIB::pmIfTx24hUAS.{#SNMPINDEX}pmIfTx24hUAS[{#SNMPVALUE}]30014d0DISABLEDCHARXTM Series::Performance MeasurementTM-3000/II Chassis | GENERIC for 1(ok) 2 (alarm) casesXTM Series | Tx Power Level on $1SNMP_AGENTLUM-PM-MIB::pmIfTxPowerLevel.{#SNMPINDEX}pmIfTxPowerLevel[{#SNMPVALUE}]30014dFLOATdBmXTM Series::Performance MeasurementMULTIPLIER0.1{ZBX-INFINERA-XTM-SERIES-MONITORING:pmIfAdminStatus[{#SNMPVALUE}].last(#1)}=2 or {ZBX-INFINERA-XTM-SERIES-MONITORING:pmIfAdminStatus[{#SNMPVALUE}].last(#1)}=3 and {ZBX-INFINERA-XTM-SERIES-MONITORING:pmIfTx24hCurrentUAS[{#SNMPVALUE}].last(#1)}>300UAS Tx 24 hour Threshold Exceeded on {#SNMPVALUE}DISABLEDWARNINGRx/Tx Power Levels on: {#SNMPVALUE}BOLD_LINE1A7C11- ZBX-INFINERA-XTM-SERIES-MONITORINGpmIfRxPowerLevel[{#SNMPVALUE}]
1BOLD_LINE3333FF- ZBX-INFINERA-XTM-SERIES-MONITORINGpmIfTxPowerLevel[{#SNMPVALUE}]
TM-3000/II Chassis | equipmentPowerDCPowerFailed0undefined1cleared2indeterminate3warning4minor5major6criticalTM-3000/II Chassis | equipmentPowerType0undefined1ac2dcTM-3000/II Chassis | GENERIC 1(notPresent) 2(down) & 3(up) cases1notPresent2down3upTM-3000/II Chassis | GENERIC for 1(ok) 2 (alarm) cases1ok2alarmTM-3000/II Chassis | pmIfAdminStatus3upXTM Series | clientIfAdminStatus1down2service3upXTM Series | clientIfRxSignalStatus1down2degraded3up2147483647notApplicable