5.02021-11-25T12:38:06ZNetworking HardwareTemplatesJuniper EXJuniper EXNetworking HardwareTemplatesDevice HealthInterfacesPerformance- Ping checkSIMPLEicmpping30Device HealthService state{sum(#3)}=0 or ({TRIGGER.VALUE}=1 and {sum(#3)}<>3)Ping checkDISASTERThe switch has stopped responding to ICMP echo requests, and is likely offline.
Please investigate.
- Red alarmSNMP_AGENT.1.3.6.1.4.1.2636.3.4.2.3.1.0RedAlarm30alarm(s)Device Health{last(0)}<>2Red Alarm on {HOSTNAME}HIGHA red alarm is reporting on this device. Please login to the CLI and check what this alert has been caused by.
- UptimeSNMP_AGENT.1.3.6.1.2.1.1.3.0Uptime60sDevice HealthMULTIPLIER0.01{last(0)}<600{HOSTNAME} has just been restartedINFO
- Yellow alarmSNMP_AGENT.1.3.6.1.4.1.2636.3.4.2.2.1.0YellowAlarm60alarm(s)Device Health{last(0)}<>2Yellow Alarm on {HOSTNAME}AVERAGEA yellow alarm is reporting on this device. Please login to the CLI and check what this alert has been caused by.
JunOS InterfacesSNMP_AGENTdiscovery[{#SNMPVALUE},1.3.6.1.2.1.2.2.1.2]discovery.ifDescr300{#SNMPVALUE}^(fe|ge|xe)-[0-9]+\/[0-9]+\/[0-9]+\.[0-9]+$|^(fe|ge|xe)-[0-9]+\/[0-9]+\/[0-9]+$|^(ae|reth|st)[0-9]+\.[0-9]+$|^(ae|reth|st)[0-9]$|^vcp-[0-9]+$|^vlan.[0-9]+$A{#SNMPVALUE} - Inbound discarded packetsSNMP_AGENT.1.3.6.1.2.1.2.2.1.13.{#SNMPINDEX}.1.3.6.1.2.1.2.2.1.13.[{#SNMPINDEX}]307dInterfacesCHANGE_PER_SECOND{#SNMPVALUE} - Inbound trafficSNMP_AGENT1.3.6.1.2.1.2.2.1.10.{#SNMPINDEX}1.3.6.1.2.1.2.2.1.10.[{#SNMPINDEX}]307dFLOATbpsInterfacesCHANGE_PER_SECONDMULTIPLIER8{#SNMPVALUE} - Inbound errorsSNMP_AGENT1.3.6.1.2.1.2.2.1.14.{#SNMPINDEX}1.3.6.1.2.1.2.2.1.14.[{#SNMPINDEX}]307dInterfacesCHANGE_PER_SECOND{#SNMPVALUE} - Outbound trafficSNMP_AGENT1.3.6.1.2.1.2.2.1.16.{#SNMPINDEX}1.3.6.1.2.1.2.2.1.16.[{#SNMPINDEX}]307dFLOATbpsInterfacesCHANGE_PER_SECONDMULTIPLIER8{#SNMPVALUE} - Outbound discarded packetsSNMP_AGENT1.3.6.1.2.1.2.2.1.19.{#SNMPINDEX}1.3.6.1.2.1.2.2.1.19.[{#SNMPINDEX}]307dInterfacesCHANGE_PER_SECOND{#SNMPVALUE} - Outbound errorsSNMP_AGENT1.3.6.1.2.1.2.2.1.20.{#SNMPINDEX}1.3.6.1.2.1.2.2.1.20.[{#SNMPINDEX}]307dInterfacesCHANGE_PER_SECONDInterface {#SNMPVALUE}FILLED_REGION2618B1RIGHT- Juniper EX1.3.6.1.2.1.2.2.1.10.[{#SNMPINDEX}]
1594CD8RIGHT- Juniper EX.1.3.6.1.2.1.2.2.1.13.[{#SNMPINDEX}]
27B72D8RIGHT- Juniper EX1.3.6.1.2.1.2.2.1.14.[{#SNMPINDEX}]
3BOLD_LINEFFC600RIGHT- Juniper EX1.3.6.1.2.1.2.2.1.16.[{#SNMPINDEX}]
4FFD440RIGHT- Juniper EX1.3.6.1.2.1.2.2.1.19.[{#SNMPINDEX}]
5FFE073RIGHT- Juniper EX1.3.6.1.2.1.2.2.1.20.[{#SNMPINDEX}]
JunOS HardwareSNMP_AGENTdiscovery[{#SNMPVALUE},1.3.6.1.4.1.2636.3.1.14.1.2.9]jnxRedundancyL1Index300Switch {#SNMPVALUE} - 5 min load avarageSNMP_AGENT.1.3.6.1.4.1.2636.3.1.13.1.21.9.{#SNMPVALUE}.0.0jnxOperating5MinLoadAvg.[{#SNMPVALUE}]307dDevice HealthSwitch {#SNMPVALUE} - Memory usageSNMP_AGENT.1.3.6.1.4.1.2636.3.1.13.1.11.9.{#SNMPVALUE}.0.0jnxOperatingBuffer.[{#SNMPVALUE}]307d%Device Health{last(0)}>70 and {last(0)}<95{HOSTNAME} {#SNMPVALUE} - Memory usage above 70%AVERAGE{last(0)}>95{HOSTNAME} {#SNMPVALUE} - Memory usage above 95%HIGHSwitch {#SNMPVALUE} - CPU usageSNMP_AGENT.1.3.6.1.4.1.2636.3.1.13.1.8.9.{#SNMPVALUE}.0.0jnxOperatingCPU.[{#SNMPVALUE}]307d%Device HealthSwitch {#SNMPVALUE} - Routing engine temperatureSNMP_AGENT.1.3.6.1.4.1.2636.3.1.13.1.7.9.{#SNMPVALUE}.0.0jnxOperatingTemp.[{#SNMPVALUE}]307d°CDevice Health{min(60)}>60{HOSTNAME} {#SNMPVALUE} - High temperatureHIGHThe temperature of this switch is above 60ºC.
Please check the status of the fans and environmental conditions immediately.{Juniper EX:jnxOperatingCPU.[{#SNMPVALUE}].min(30)}>70 and {Juniper EX:jnxOperatingCPU.[{#SNMPVALUE}].min(30)}<95 and {Juniper EX:jnxOperating5MinLoadAvg.[{#SNMPVALUE}].last(30)}>100 and {Juniper EX:jnxOperating5MinLoadAvg.[{#SNMPVALUE}].last(0)}<300{HOSTNAME} {#SNMPVALUE} - CPU usage above 70%AVERAGEThe CPU load on this node has increased to over 70%. If this is a sudden or unexpected increase, immediate investigation is advised.{Juniper EX:jnxOperating5MinLoadAvg.[{#SNMPVALUE}].last(0)}>300 and {Juniper EX:jnxOperatingCPU.[{#SNMPVALUE}].last(0)}>95{HOSTNAME} {#SNMPVALUE} - High CPU usage (95%)HIGHThe CPU load on this node has increased to over 95%. If this is a sudden or unexpected increase, immediate investigation is advised.Service state0Down1Up