5.02021-11-21T21:38:21ZTemplatesSNMP Extreme EXOSSNMP Extreme EXOS## Overview
HARDWARE
FIRMWARE
STACKING
TemplatesCPUFansInventoryMemoryPower SupplyStackTemperature- Device: Temperature statusSNMP_AGENT1.3.6.1.4.1.1916.1.1.1.7.0sensor.temp.status[extremeOverTemperatureAlarm.0]60MIB: EXTREME-SYSTEM-MIB
Temperature status of testpoint: DeviceTemperatureEXTREME-SYSTEM-MIB::extremeOverTemperatureAlarm
- Device: TemperatureSNMP_AGENT1.3.6.1.4.1.1916.1.1.1.8.0sensor.temp.value[extremeCurrentTemperature.0]60°CMIB: EXTREME-SYSTEM-MIB
Temperature readings of testpoint: Device
Reference: https://gtacknowledge.extremenetworks.com/articles/Q_A/Does-EXOS-support-temperature-polling-via-SNMP-on-all-nodes-in-a-stackTemperature{avg(5m)}>65Device: Temperature is above critical thresholdHIGH{avg(5m)}>55Device: Temperature is above warning thresholdWARNING{avg(5m)}<5Device: Temperature is too lowHIGH
- CPU utilizationSNMP_AGENT1.3.6.1.4.1.1916.1.32.1.2.0system.cpu.util[extremeCpuMonitorTotalUtilization.0]60%MIB: EXTREME-SOFTWARE-MONITOR-MIB
Total CPU utlization (percentage) as of last sampling.CPU{avg(5m)}>80Processor load is too high on {HOST.NAME}HIGH
- Firmware versionSNMP_AGENT1.3.6.1.2.1.47.1.1.1.1.9.1system.hw.firmware36000TEXTSOFTWAREInventory
- Hardware model nameSNMP_AGENT1.3.6.1.2.1.47.1.1.1.1.2.1system.hw.model36000TEXTInventory
- Operating systemSNMP_AGENT1.3.6.1.4.1.1916.1.1.1.13.0system.hw.os36000TEXTMIB: EXTREME-SYSTEM-MIB
The software revision of the primary image stored in this device.
This string will have a zero length if the revision is unknown, invalid or not present.
This will also be reported in RMON2 probeSoftwareRev if this is the software image currently running in the deviceSOFTWARE_FULLInventory
- Hardware serial numberSNMP_AGENT1.3.6.1.2.1.47.1.1.1.1.11.1system.hw.serialnumber36000TEXTSERIALNO_AInventory
Stack port InfoSNMP_AGENTdiscovery[{#SNMPVALUE}, 1.3.6.1.4.1.1916.1.33.3.1.1]extremeStackingPortIfIndex3600A unique value for each interface. Its value ranges between 1 and the value of ifNumber. The value for each interface must remain constant at least from one re-initialization of the entity's network management system to the next re- initialization.Stack port {#SNMPINDEX} statusSNMP_AGENT1.3.6.1.4.1.1916.1.33.3.1.4.{#SNMPINDEX}extremeStackingPortLinkStatus[{#SNMPINDEX}]30The Link status of the stacking port linkStackEXTREME-STACKING-MIB::extremeOperStatus{last()}<>1Stack port {#SNMPVALUE}: Member is in critical stateHIGHStack InfoSNMP_AGENTdiscovery[{#SNMPVALUE}, 1.3.6.1.4.1.9.9.500.1.2.1.1.1]extremeStackMemberSlotId3600The slot id of the stack member in the stack#{#SNMPVALUE}: Member MAC addressSNMP_AGENT1.3.6.1.4.1.1916.1.33.2.1.6.{#SNMPINDEX}extremeStackMemberMavAddress[{#SNMPVALUE}]36000TEXTThe Mac address of the stack memberStack#{#SNMPVALUE}: Member mgmt ip addressSNMP_AGENT1.3.6.1.4.1.1916.1.33.2.1.15.{#SNMPINDEX}extremeStackMemberMgmtIpAddress[{#SNMPVALUE}]36000TEXTThe fallback mgmt ip address which was configured through CLI for this stack member. This ipaddress can be used to communicate with this member, if it comes up as the master. The ipaddress is associated with the vlan configuredStack#{#SNMPVALUE}: Member oper statusSNMP_AGENT1.3.6.1.4.1.1916.1.33.2.1.3.{#SNMPINDEX}extremeStackMemberOperStatus[{#SNMPVALUE}]60The operational status of the stack member. When the stack comes up, if there is a vector mismatch namely license mismatch or platform mismatch between the master and the member, the member remains in the mismatch state. Further communication with the member is not possibleStackEXTREME-STACKING-MIB::extremeOperStatus{last()}<>1Stack {#SNMPVALUE}: Member is in critical stateHIGH#{#SNMPVALUE}: Member roleSNMP_AGENT1.3.6.1.4.1.1916.1.33.2.1.4.{#SNMPINDEX}extremeStackMemberRole[{#SNMPVALUE}]3600The role of the stack member as to whether it is acting as a master,backup or a slaveStackEXTREME-STACKING-MIB::extremeMemberRole#{#SNMPVALUE}: Member stack prioritySNMP_AGENT1.3.6.1.4.1.1916.1.33.2.1.14.{#SNMPINDEX}extremeStackMemberStackPriority[{#SNMPVALUE}]3600The stack priority of the stack member. The stack priority is used for the master election algorithm. The member with the highest priority comes up as the master. If there are more than one switch with highest priority, the member with the least MAC among them comes up as the masterStackFAN DiscoverySNMP_AGENTdiscovery[{#SNMPVALUE},1.3.6.1.4.1.1916.1.1.1.9.1.1]fan.discovery3600Fan {#SNMPVALUE}: Fan speedSNMP_AGENT1.3.6.1.4.1.1916.1.1.1.9.1.4.{#SNMPINDEX}sensor.fan.speed[extremeFanSpeed.{#SNMPINDEX}]60rpmMIB: EXTREME-SYSTEM-MIB
The speed (RPM) of a cooling fan in the fantray {#SNMPVALUE}FansFan {#SNMPVALUE}: Fan statusSNMP_AGENT1.3.6.1.4.1.1916.1.1.1.9.1.2.{#SNMPINDEX}sensor.fan.status[extremeFanOperational.{#SNMPINDEX}]60MIB: EXTREME-SYSTEM-MIB
Operational status of a cooling fan.FansEXTREME-SYSTEM-MIB::extremeFanOperational{last()}<>1Fan {#SNMPVALUE}: Fan is in critical stateHIGHMemory DiscoverySNMP_AGENTdiscovery[{#SNMPVALUE},1.3.6.1.4.1.1916.1.32.2.2.1.1]memory.discovery3600#{#SNMPVALUE}: Available memorySNMP_AGENT1.3.6.1.4.1.1916.1.32.2.2.1.3.{#SNMPINDEX}vm.memory.free[extremeMemoryMonitorSystemFree.{#SNMPINDEX}]60BMIB: EXTREME-SOFTWARE-MONITOR-MIB
Total amount of free memory in Kbytes in the system.Memory#{#SNMPVALUE}: Memory utilizationCALCULATEDvm.memory.pused[{#SNMPVALUE}]60%((last(vm.memory.total[extremeMemoryMonitorSystemTotal.{#SNMPINDEX}])-last(vm.memory.free[extremeMemoryMonitorSystemFree.{#SNMPINDEX}]))/last(vm.memory.total[extremeMemoryMonitorSystemTotal.{#SNMPINDEX}]))*100Memory utilization in %Memory{avg(5m)}>90#{#SNMPVALUE}: High memory utilizationHIGH#{#SNMPVALUE}: Total memorySNMP_AGENT1.3.6.1.4.1.1916.1.32.2.2.1.2.{#SNMPINDEX}vm.memory.total[extremeMemoryMonitorSystemTotal.{#SNMPINDEX}]60BMIB: EXTREME-SOFTWARE-MONITOR-MIB
Total amount of DRAM in Kbytes in the system.Memory#{#SNMPVALUE}: Memory utilization1A7C11- SNMP Extreme EXOSvm.memory.pused[{#SNMPVALUE}]
PSU DiscoverySNMP_AGENTdiscovery[{#SNMPVALUE},1.3.6.1.4.1.1916.1.1.1.27.1.1]psu.discovery3600Table of status of all power supplies in the system.PSU {#SNMPVALUE}: Power supply statusSNMP_AGENT1.3.6.1.4.1.1916.1.1.1.27.1.2.{#SNMPINDEX}sensor.psu.status[extremePowerSupplyStatus.{#SNMPINDEX}]60MIB: EXTREME-SYSTEM-MIB
Status of the power supply {#SNMPVALUE}Power SupplyEXTREME-SYSTEM-MIB::extremePowerSupplyStatus{last()}<>3PSU {#SNMPVALUE}: Power supply is in critical stateHIGH{last()}<>4PSU {#SNMPVALUE}: Power supply power offWARNINGCPU utilization1A7C11- SNMP Extreme EXOSsystem.cpu.util[extremeCpuMonitorTotalUtilization.0]
EXTREME-STACKING-MIB::extremeMemberRole1master2slave3backupEXTREME-STACKING-MIB::extremeOperStatus1up2down3mismatchEXTREME-SYSTEM-MIB::extremeFanOperational1true - on2false - offEXTREME-SYSTEM-MIB::extremeOverTemperatureAlarm1alarm2normalEXTREME-SYSTEM-MIB::extremePowerSupplyStatus1notPresent2presentOK3presentNotOK4presentPowerOff