zabbix_export: version: '6.0' date: '2021-11-21T21:38:23Z' groups: - uuid: 7df96b18c230490a9a0a9e2307226338 name: Templates templates: - uuid: 81607ef7a3d94dbb991b9efa6b08ce01 template: 'SNMP Extreme EXOS' name: 'SNMP Extreme EXOS' description: | ## Overview HARDWARE FIRMWARE STACKING groups: - name: Templates items: - uuid: 4346df67ac0f442384d4e1cc47163a02 name: 'Device: Temperature status' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.1916.1.1.1.7.0 key: 'sensor.temp.status[extremeOverTemperatureAlarm.0]' delay: '60' description: | MIB: EXTREME-SYSTEM-MIB Temperature status of testpoint: Device valuemap: name: 'EXTREME-SYSTEM-MIB::extremeOverTemperatureAlarm' tags: - tag: Application value: Temperature - uuid: 4d6ce7a8ca6548ae95b629f4f1e1d2eb name: 'Device: Temperature' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.1916.1.1.1.8.0 key: 'sensor.temp.value[extremeCurrentTemperature.0]' delay: '60' units: °C description: | MIB: EXTREME-SYSTEM-MIB Temperature readings of testpoint: Device Reference: https://gtacknowledge.extremenetworks.com/articles/Q_A/Does-EXOS-support-temperature-polling-via-SNMP-on-all-nodes-in-a-stack tags: - tag: Application value: Temperature triggers: - uuid: f61f5325c58f4cb78ddeedb34019c02f expression: 'avg(/SNMP Extreme EXOS/sensor.temp.value[extremeCurrentTemperature.0],5m)>65' name: 'Device: Temperature is above critical threshold' priority: HIGH - uuid: ed96d0a1eb8844899c27e1f853de25bd expression: 'avg(/SNMP Extreme EXOS/sensor.temp.value[extremeCurrentTemperature.0],5m)>55' name: 'Device: Temperature is above warning threshold' priority: WARNING - uuid: 8674683521e14203b851bdfe99b3e615 expression: 'avg(/SNMP Extreme EXOS/sensor.temp.value[extremeCurrentTemperature.0],5m)<5' name: 'Device: Temperature is too low' priority: HIGH - uuid: 6fd46726361a4c288d1dc762fae8dc9b name: 'CPU utilization' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.1916.1.32.1.2.0 key: 'system.cpu.util[extremeCpuMonitorTotalUtilization.0]' delay: '60' units: '%' description: | MIB: EXTREME-SOFTWARE-MONITOR-MIB Total CPU utlization (percentage) as of last sampling. tags: - tag: Application value: CPU triggers: - uuid: d6677e09e92c446daddab57cefcc5bf4 expression: 'avg(/SNMP Extreme EXOS/system.cpu.util[extremeCpuMonitorTotalUtilization.0],5m)>80' name: 'Processor load is too high on {HOST.NAME}' priority: HIGH - uuid: d9d26cde462349c89ed4f551f7ab2064 name: 'Firmware version' type: SNMP_AGENT snmp_oid: 1.3.6.1.2.1.47.1.1.1.1.9.1 key: system.hw.firmware delay: '3600' trends: '0' value_type: TEXT inventory_link: SOFTWARE tags: - tag: Application value: Inventory - uuid: 4f081feee15a4cd09c4c6b31b2d3e909 name: 'Hardware model name' type: SNMP_AGENT snmp_oid: 1.3.6.1.2.1.47.1.1.1.1.2.1 key: system.hw.model delay: '3600' trends: '0' value_type: TEXT tags: - tag: Application value: Inventory - uuid: 4f9857592417467098ad16c156683351 name: 'Operating system' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.1916.1.1.1.13.0 key: system.hw.os delay: '3600' trends: '0' value_type: TEXT description: | MIB: EXTREME-SYSTEM-MIB The software revision of the primary image stored in this device. This string will have a zero length if the revision is unknown, invalid or not present. This will also be reported in RMON2 probeSoftwareRev if this is the software image currently running in the device inventory_link: SOFTWARE_FULL tags: - tag: Application value: Inventory - uuid: ec20dcb54391472b8c5ce267d68414b2 name: 'Hardware serial number' type: SNMP_AGENT snmp_oid: 1.3.6.1.2.1.47.1.1.1.1.11.1 key: system.hw.serialnumber delay: '3600' trends: '0' value_type: TEXT inventory_link: SERIALNO_A tags: - tag: Application value: Inventory discovery_rules: - uuid: 42d58f7bd9e347f1b58f348c1786ad4b name: 'Stack port Info' type: SNMP_AGENT snmp_oid: 'discovery[{#SNMPVALUE}, 1.3.6.1.4.1.1916.1.33.3.1.1]' key: extremeStackingPortIfIndex delay: '3600' description: 'A unique value for each interface. Its value ranges between 1 and the value of ifNumber. The value for each interface must remain constant at least from one re-initialization of the entity''s network management system to the next re- initialization.' item_prototypes: - uuid: 820173331e5c448b8f9bcce29008a1ee name: 'Stack port {#SNMPINDEX} status' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.1916.1.33.3.1.4.{#SNMPINDEX}' key: 'extremeStackingPortLinkStatus[{#SNMPINDEX}]' delay: '30' description: 'The Link status of the stacking port link' valuemap: name: 'EXTREME-STACKING-MIB::extremeOperStatus' tags: - tag: Application value: Stack trigger_prototypes: - uuid: e3f11fae657a4a50b74fbf99130fcdd6 expression: 'last(/SNMP Extreme EXOS/extremeStackingPortLinkStatus[{#SNMPINDEX}])<>1' name: 'Stack port {#SNMPVALUE}: Member is in critical state' priority: HIGH - uuid: 3a5516c28613418b8ea2c2f1234898c0 name: 'Stack Info' type: SNMP_AGENT snmp_oid: 'discovery[{#SNMPVALUE}, 1.3.6.1.4.1.9.9.500.1.2.1.1.1]' key: extremeStackMemberSlotId delay: '3600' description: 'The slot id of the stack member in the stack' item_prototypes: - uuid: d955590894de4aff8d575db71820b8e4 name: '#{#SNMPVALUE}: Member MAC address' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.1916.1.33.2.1.6.{#SNMPINDEX}' key: 'extremeStackMemberMavAddress[{#SNMPVALUE}]' delay: '3600' trends: '0' value_type: TEXT description: 'The Mac address of the stack member' tags: - tag: Application value: Stack - uuid: 352c035aa45e4d1bbbb8238240b03918 name: '#{#SNMPVALUE}: Member mgmt ip address' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.1916.1.33.2.1.15.{#SNMPINDEX}' key: 'extremeStackMemberMgmtIpAddress[{#SNMPVALUE}]' delay: '3600' trends: '0' value_type: TEXT description: 'The fallback mgmt ip address which was configured through CLI for this stack member. This ipaddress can be used to communicate with this member, if it comes up as the master. The ipaddress is associated with the vlan configured' tags: - tag: Application value: Stack - uuid: 8f0a443d5c9c423ca890a5e5dc7c85b0 name: '#{#SNMPVALUE}: Member oper status' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.1916.1.33.2.1.3.{#SNMPINDEX}' key: 'extremeStackMemberOperStatus[{#SNMPVALUE}]' delay: '60' description: 'The operational status of the stack member. When the stack comes up, if there is a vector mismatch namely license mismatch or platform mismatch between the master and the member, the member remains in the mismatch state. Further communication with the member is not possible' valuemap: name: 'EXTREME-STACKING-MIB::extremeOperStatus' tags: - tag: Application value: Stack trigger_prototypes: - uuid: 8bdcde29c9524aa19bef0f6904776ec1 expression: 'last(/SNMP Extreme EXOS/extremeStackMemberOperStatus[{#SNMPVALUE}])<>1' name: 'Stack {#SNMPVALUE}: Member is in critical state' priority: HIGH - uuid: 3c7ff3519fd64a63923e626b17f1e8ee name: '#{#SNMPVALUE}: Member role' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.1916.1.33.2.1.4.{#SNMPINDEX}' key: 'extremeStackMemberRole[{#SNMPVALUE}]' delay: '3600' description: 'The role of the stack member as to whether it is acting as a master,backup or a slave' valuemap: name: 'EXTREME-STACKING-MIB::extremeMemberRole' tags: - tag: Application value: Stack - uuid: 66e4ccf747f645ecba71242fa428259b name: '#{#SNMPVALUE}: Member stack priority' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.1916.1.33.2.1.14.{#SNMPINDEX}' key: 'extremeStackMemberStackPriority[{#SNMPVALUE}]' delay: '3600' description: 'The stack priority of the stack member. The stack priority is used for the master election algorithm. The member with the highest priority comes up as the master. If there are more than one switch with highest priority, the member with the least MAC among them comes up as the master' tags: - tag: Application value: Stack - uuid: 5b6e1d38b24b4f66889893005090d2ba name: 'FAN Discovery' type: SNMP_AGENT snmp_oid: 'discovery[{#SNMPVALUE},1.3.6.1.4.1.1916.1.1.1.9.1.1]' key: fan.discovery delay: '3600' item_prototypes: - uuid: b8922adf30294c32aff829165417bf4f name: 'Fan {#SNMPVALUE}: Fan speed' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.1916.1.1.1.9.1.4.{#SNMPINDEX}' key: 'sensor.fan.speed[extremeFanSpeed.{#SNMPINDEX}]' delay: '60' units: rpm description: | MIB: EXTREME-SYSTEM-MIB The speed (RPM) of a cooling fan in the fantray {#SNMPVALUE} tags: - tag: Application value: Fans - uuid: 192bdf2b1d8449ea95980887074f12af name: 'Fan {#SNMPVALUE}: Fan status' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.1916.1.1.1.9.1.2.{#SNMPINDEX}' key: 'sensor.fan.status[extremeFanOperational.{#SNMPINDEX}]' delay: '60' description: | MIB: EXTREME-SYSTEM-MIB Operational status of a cooling fan. valuemap: name: 'EXTREME-SYSTEM-MIB::extremeFanOperational' tags: - tag: Application value: Fans trigger_prototypes: - uuid: 36539d563da245939317e82c612f805c expression: 'last(/SNMP Extreme EXOS/sensor.fan.status[extremeFanOperational.{#SNMPINDEX}])<>1' name: 'Fan {#SNMPVALUE}: Fan is in critical state' priority: HIGH - uuid: 5c826b1c2a424139af3085ddfaccb329 name: 'Memory Discovery' type: SNMP_AGENT snmp_oid: 'discovery[{#SNMPVALUE},1.3.6.1.4.1.1916.1.32.2.2.1.1]' key: memory.discovery delay: '3600' item_prototypes: - uuid: 0309a6a01d2e449d890c4a7f65b8758d name: '#{#SNMPVALUE}: Available memory' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.1916.1.32.2.2.1.3.{#SNMPINDEX}' key: 'vm.memory.free[extremeMemoryMonitorSystemFree.{#SNMPINDEX}]' delay: '60' units: B description: | MIB: EXTREME-SOFTWARE-MONITOR-MIB Total amount of free memory in Kbytes in the system. tags: - tag: Application value: Memory - uuid: 65bc8b8abf8140fc80d91a9ad9ad5110 name: '#{#SNMPVALUE}: Memory utilization' type: CALCULATED key: 'vm.memory.pused[{#SNMPVALUE}]' delay: '60' units: '%' params: '((last(//vm.memory.total[extremeMemoryMonitorSystemTotal.{#SNMPINDEX}])-last(//vm.memory.free[extremeMemoryMonitorSystemFree.{#SNMPINDEX}]))/last(//vm.memory.total[extremeMemoryMonitorSystemTotal.{#SNMPINDEX}]))*100' description: 'Memory utilization in %' tags: - tag: Application value: Memory trigger_prototypes: - uuid: b932ac2520d548cbaca739823cdfa129 expression: 'avg(/SNMP Extreme EXOS/vm.memory.pused[{#SNMPVALUE}],5m)>90' name: '#{#SNMPVALUE}: High memory utilization' priority: HIGH - uuid: 6a943161c8024b699446605822222cea name: '#{#SNMPVALUE}: Total memory' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.1916.1.32.2.2.1.2.{#SNMPINDEX}' key: 'vm.memory.total[extremeMemoryMonitorSystemTotal.{#SNMPINDEX}]' delay: '60' units: B description: | MIB: EXTREME-SOFTWARE-MONITOR-MIB Total amount of DRAM in Kbytes in the system. tags: - tag: Application value: Memory graph_prototypes: - uuid: 7d11a5961bfe4061a54deaf8d61c03b9 name: '#{#SNMPVALUE}: Memory utilization' graph_items: - color: 1A7C11 item: host: 'SNMP Extreme EXOS' key: 'vm.memory.pused[{#SNMPVALUE}]' - uuid: ebdfa6e1b4f64c318fc87ff27507f436 name: 'PSU Discovery' type: SNMP_AGENT snmp_oid: 'discovery[{#SNMPVALUE},1.3.6.1.4.1.1916.1.1.1.27.1.1]' key: psu.discovery delay: '3600' description: 'Table of status of all power supplies in the system.' item_prototypes: - uuid: 968e316ea21347dabeb950427028f42d name: 'PSU {#SNMPVALUE}: Power supply status' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.1916.1.1.1.27.1.2.{#SNMPINDEX}' key: 'sensor.psu.status[extremePowerSupplyStatus.{#SNMPINDEX}]' delay: '60' description: | MIB: EXTREME-SYSTEM-MIB Status of the power supply {#SNMPVALUE} valuemap: name: 'EXTREME-SYSTEM-MIB::extremePowerSupplyStatus' tags: - tag: Application value: 'Power Supply' trigger_prototypes: - uuid: 53216198a2684bf49a5e5b80e8e93c00 expression: 'last(/SNMP Extreme EXOS/sensor.psu.status[extremePowerSupplyStatus.{#SNMPINDEX}])<>3' name: 'PSU {#SNMPVALUE}: Power supply is in critical state' priority: HIGH - uuid: 8c448cb4f71b45418c6e02952f4cc56f expression: 'last(/SNMP Extreme EXOS/sensor.psu.status[extremePowerSupplyStatus.{#SNMPINDEX}])<>4' name: 'PSU {#SNMPVALUE}: Power supply power off' priority: WARNING valuemaps: - uuid: 4ba7b40602c94e1a93fe79b3fd640622 name: 'EXTREME-STACKING-MIB::extremeMemberRole' mappings: - value: '1' newvalue: master - value: '2' newvalue: slave - value: '3' newvalue: backup - uuid: dd1aa802ef6d48ac987fcfb02d1f1140 name: 'EXTREME-STACKING-MIB::extremeOperStatus' mappings: - value: '1' newvalue: up - value: '2' newvalue: down - value: '3' newvalue: mismatch - uuid: 9f955674390a4fc1b74aab526a9326d2 name: 'EXTREME-SYSTEM-MIB::extremeFanOperational' mappings: - value: '1' newvalue: 'true - on' - value: '2' newvalue: 'false - off' - uuid: da8433690a194e7b800df43057523b7f name: 'EXTREME-SYSTEM-MIB::extremeOverTemperatureAlarm' mappings: - value: '1' newvalue: alarm - value: '2' newvalue: normal - uuid: 0da10f6566c44c6088a29b6653d452b9 name: 'EXTREME-SYSTEM-MIB::extremePowerSupplyStatus' mappings: - value: '1' newvalue: notPresent - value: '2' newvalue: presentOK - value: '3' newvalue: presentNotOK - value: '4' newvalue: presentPowerOff graphs: - uuid: b06bb8b0c6e649388688cafc3aca1ee2 name: 'CPU utilization' graph_items: - color: 1A7C11 item: host: 'SNMP Extreme EXOS' key: 'system.cpu.util[extremeCpuMonitorTotalUtilization.0]'