zabbix_export: version: '6.0' date: '2021-11-21T22:01:47Z' groups: - uuid: 7df96b18c230490a9a0a9e2307226338 name: Templates templates: - uuid: 21031d49f8914b1885e78d21fd5ea34e template: 'Ciena 6500 2' name: 'Ciena 6500 2' description: | ## Overview This template will discover and monitor various optical interfaces - mainly light levels and baselines and alert if light levels fall outside of VARIANCE macro. Also will report when OSC has no light and serve a clear indication that there is a fiber issue. No MIBs required. Used OIDs. No Dependencies - just enable SNMP with v2 community on the shelf and set SNMP\_COMMUNITY macro in template. ## Author Dustin Howard groups: - name: Templates items: - uuid: f93e6de297624b338630916d14dc045e name: 'Number of Critical Alarms' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.562.68.11.4.1.1.0 key: ciena.critical.alarms delay: 5m value_type: FLOAT description: 'This is the number of critical alarms that currently exist at this node which may have one or more shelves.' tags: - tag: Application value: Alarms triggers: - uuid: f319b4d12e224e0a883088eb0a7d703f expression: '(change(/Ciena 6500 2/ciena.critical.alarms)>0) and ({TRIGGER.VALUE}=0)' recovery_mode: RECOVERY_EXPRESSION recovery_expression: | ((change(/Ciena 6500 2/ciena.critical.alarms)<0) and ({TRIGGER.VALUE}=1) and last(/Ciena 6500 2/ciena.critical.alarms,#1)=last(/Ciena 6500 2/ciena.critical.alarms,#288)) name: 'Critical Alarm Exists' priority: HIGH description: 'Critical alarms exist on node. For alarm details you will need to connect to host via site manager.' manual_close: 'YES' - uuid: 21fa182067f2438caf8b006d5c665e54 name: 'Number of Major Alarms' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.562.68.11.4.1.2.0 key: ciena.major.alarms delay: 5m value_type: FLOAT description: 'This is the number of major alarms that currently exist at this node which may have one or more shelves.' tags: - tag: Application value: Alarms triggers: - uuid: b8a9b95a90cc4fa4ae97e4766de8bf58 expression: '(change(/Ciena 6500 2/ciena.major.alarms)>0) and ({TRIGGER.VALUE}=0)' recovery_mode: RECOVERY_EXPRESSION recovery_expression: | ((change(/Ciena 6500 2/ciena.major.alarms)<0) and ({TRIGGER.VALUE}=1) and last(/Ciena 6500 2/ciena.major.alarms,#1)=last(/Ciena 6500 2/ciena.major.alarms,#288)) name: 'Major Alarm Exists' priority: AVERAGE description: 'Major alarms exist on node. For alarm details you will need to connect to host via site manager.' manual_close: 'YES' - uuid: 396f2cfe1df24684a13f68834fcc5d3a name: 'Number of Minor Alarms' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.562.68.11.4.1.3.0 key: ciena.minor.alarms delay: 5m value_type: FLOAT description: 'This is the number of minor alarms that currently exist at this node which may have one or more shelves.' tags: - tag: Application value: Alarms triggers: - uuid: a8db7b9af42e476ca22313a7c13f94b1 expression: '(change(/Ciena 6500 2/ciena.minor.alarms)>0) and ({TRIGGER.VALUE}=0)' recovery_mode: RECOVERY_EXPRESSION recovery_expression: | ((change(/Ciena 6500 2/ciena.minor.alarms)<0) and ({TRIGGER.VALUE}=1) and last(/Ciena 6500 2/ciena.minor.alarms,#1)=last(/Ciena 6500 2/ciena.minor.alarms,#288)) name: 'Minor Alarm Exists' priority: WARNING description: 'Minor alarms exist on node. For alarm details you will need to connect to host via site manager.' manual_close: 'YES' - uuid: 55f06b67d260448eb5bb2797b1b14636 name: 'Number of Warnings' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.562.68.11.4.1.4.0 key: ciena.warnings delay: 5m value_type: FLOAT description: 'This is the number of warnings that currently exist at this node which may have one or more shelves.' tags: - tag: Application value: Alarms triggers: - uuid: c0e0e88ee84048dd9d6b2f3fe2a31b0a expression: '(change(/Ciena 6500 2/ciena.warnings)>0) and ({TRIGGER.VALUE}=0)' recovery_mode: RECOVERY_EXPRESSION recovery_expression: | ((change(/Ciena 6500 2/ciena.warnings)<0) and ({TRIGGER.VALUE}=1) and last(/Ciena 6500 2/ciena.warnings,#1)=last(/Ciena 6500 2/ciena.warnings,#288)) name: 'Warning Alarm Exists' priority: INFO description: 'Warning alarms exist on node. For alarm details you will need to connect to host via site manager.' manual_close: 'YES' - uuid: de54a8c533bd4cdbab63becfcebdb3a7 name: 'Software Version' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.562.68.11.1.1.5.0 key: software.version delay: 6h history: 14d trends: '0' value_type: CHAR inventory_link: OS tags: - tag: Application value: General - uuid: 16bfd780dcf04282ba7805a4a0c9512a name: 'Device Uptime' type: SNMP_AGENT snmp_oid: 1.3.6.1.2.1.1.3.0 key: system.uptime delay: 5m history: 14d trends: '0' units: s description: 'The time (in seconds) since the network management portion of the system was last re-initialized.' preprocessing: - type: MULTIPLIER parameters: - '0.01' triggers: - uuid: f8885bd9d2e44ab2ad4994c7e53ac291 expression: | last(/Ciena 6500 2/system.uptime,#1)<8m and last(/Ciena 6500 2/system.uptime,#3)<42948779 name: 'System Restarted' priority: AVERAGE description: 'This trigger will indicate if the device has restarted. The uptime is less than 10 minutes.' discovery_rules: - uuid: 7c1038ff06e9429baf9daf5fd8b9af58 name: 'Shelf Inventory Discovery' type: SNMP_AGENT snmp_oid: 'discovery[{#DESCRIPTION},.1.3.6.1.2.1.47.1.1.1.1.2,{#MODEL},.1.3.6.1.2.1.47.1.1.1.1.13,{#CONTAINER},.1.3.6.1.2.1.47.1.1.1.1.7]' key: enventory.discovery delay: 1d;wd1h8 filter: conditions: - macro: '{#MODEL}' value: . formulaid: A item_prototypes: - uuid: b635525ad16648e1a95ae0f604c0dc94 name: 'Serial Number: "{#DESCRIPTION}" in {#CONTAINER} MODEL-{#MODEL}' type: SNMP_AGENT snmp_oid: '1.3.6.1.2.1.47.1.1.1.1.11.{#SNMPINDEX}' key: 'serial.number.[{#SNMPINDEX}]' delay: 1d trends: '0' value_type: CHAR description: 'The serial number for this module.' tags: - tag: Application value: Inventory - uuid: 422815e7dd1748eaaa091219c4b16f4a name: 'Ethernet Interface Discovery' type: SNMP_AGENT snmp_oid: 'discovery[{#IFADMINSTATUS},1.3.6.1.2.1.2.2.1.7,{#IFDESCR},1.3.6.1.2.1.2.2.1.2]' key: ethernet.transport.if.discovery delay: 1d;wd1h14 filter: evaltype: AND conditions: - macro: '{#IFDESCR}' value: ETH formulaid: B - macro: '{#IFADMINSTATUS}' value: '1' formulaid: A item_prototypes: - uuid: 3f818c5621d3473c9cdb9eca28294c71 name: '{#IFDESCR}: Bits Received' type: SNMP_AGENT snmp_oid: '1.3.6.1.2.1.31.1.1.1.6.{#SNMPINDEX}' key: 'ciena6500.ethernet.if.bits.in[{#SNMPINDEX}]' delay: 5m units: bps description: 'The total number of bits per second received on the interface.' preprocessing: - type: CHANGE_PER_SECOND parameters: - '' - type: MULTIPLIER parameters: - '8' tags: - tag: Application value: 'Ethernet Interface' - uuid: 90b8ccc2eb42413889d88ac804ee11c1 name: '{#IFDESCR}: Bits Sent' type: SNMP_AGENT snmp_oid: '1.3.6.1.2.1.31.1.1.1.10.{#SNMPINDEX}' key: 'ciena6500.ethernet.if.bits.out[{#SNMPINDEX}]' delay: 5m units: bps description: 'The total number of bits per second sent on the interface.' preprocessing: - type: CHANGE_PER_SECOND parameters: - '' - type: MULTIPLIER parameters: - '8' tags: - tag: Application value: 'Ethernet Interface' - uuid: 88a86c13bed74a92999029902ff65761 name: '{#IFDESCR}: Ethernet Errors' type: SNMP_AGENT snmp_oid: '1.3.6.1.2.1.2.2.1.14.{#SNMPINDEX}' key: 'ciena6500.ethernet.if.errors.in[{#SNMPINDEX}]' delay: 5m units: 'errors per second' description: 'The average number of inbound packets per second that contained errors preventing them from being deliverable to a higher-layer protocol.' preprocessing: - type: CHANGE_PER_SECOND parameters: - '' tags: - tag: Application value: 'Ethernet Interface' - uuid: 24d02d94d941437b94bbbdcf1eb06b9e name: '{#IFDESCR}: Admin status' type: SNMP_AGENT snmp_oid: '1.3.6.1.2.1.2.2.1.7.{#SNMPINDEX}' key: 'ethernet.if.status[ifAdminStatus.{#SNMPINDEX}]' delay: 5m description: 'The administrative state of the interface.' valuemap: name: 'Interface Admin Status' tags: - tag: Application value: 'Ethernet Interface' - uuid: 3d4436dedc7540048dd280bea84d77d1 name: '{#IFDESCR}: Operational status' type: SNMP_AGENT snmp_oid: '1.3.6.1.2.1.2.2.1.8.{#SNMPINDEX}' key: 'ethernet.if.status[ifOperStatus.{#SNMPINDEX}]' delay: 5m description: 'The operational state of the interface.' valuemap: name: 'Interface Operational Status' tags: - tag: Application value: 'Ethernet Interface' trigger_prototypes: - uuid: 7a25b2519ccd4f77bea95c84f3c6d201 expression: 'last(/Ciena 6500 2/ethernet.if.status[ifOperStatus.{#SNMPINDEX}],#1)<>1 and last(/Ciena 6500 2/ethernet.if.status[ifAdminStatus.{#SNMPINDEX}],#1:now-1s)=1' name: '{#IFDESCR} DOWN' priority: WARNING description: 'The operational status of this Ethernet interface is DOWN.' graph_prototypes: - uuid: c6527fb6623c4db5b1da0a5164aee045 name: '{#IFDESCR}): Ethernet traffic' graph_items: - drawtype: GRADIENT_LINE color: 4CAF50 item: host: 'Ciena 6500 2' key: 'ciena6500.ethernet.if.bits.in[{#SNMPINDEX}]' - sortorder: '1' drawtype: BOLD_LINE color: 2774A4 item: host: 'Ciena 6500 2' key: 'ciena6500.ethernet.if.bits.out[{#SNMPINDEX}]' - sortorder: '2' drawtype: BOLD_LINE color: F63100 item: host: 'Ciena 6500 2' key: 'ciena6500.ethernet.if.errors.in[{#SNMPINDEX}]' - uuid: 04a4d4af258f4b649709c31fe7e90c4e name: 'Optical OSC Discovery' type: SNMP_AGENT snmp_oid: 'discovery[{#PORTNAME},.1.3.6.1.4.1.562.68.10.1.1.1.1.1.3,{#CHECKNAME},.1.3.6.1.4.1.562.68.10.1.1.1.1.1.4]' key: optical.osc.discovery delay: 1d;wd1h9 filter: conditions: - macro: '{#CHECKNAME}' value: 'OPR-OCH NEND RCV' formulaid: A - macro: '{#PORTNAME}' value: 'OSC-.*' formulaid: B item_prototypes: - uuid: 63d778a027bc445692f17edceef9d315 name: '{#PORTNAME} "{#CHECKNAME}"' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.562.68.10.1.1.1.1.1.6.{#SNMPINDEX}' key: 'optical.osc[{#PORTNAME}.{#CHECKNAME}]' value_type: FLOAT units: dbm description: 'The OSC received light level in dbm.' tags: - tag: Application value: 'Optical AMP/OSC' - uuid: faeb056e5e4f4d538eb488538a4676ce name: 'Optical OSC Spanloss Discovery' type: SNMP_AGENT snmp_oid: 'discovery[{#PORTNAME},.1.3.6.1.4.1.562.68.10.1.1.1.1.1.3,{#CHECKNAME},.1.3.6.1.4.1.562.68.10.1.1.1.1.1.4]' key: optical.osc.spanloss.discovery delay: 1d;wd1h10 filter: conditions: - macro: '{#PORTNAME}' value: 'OSC.*' formulaid: B - macro: '{#CHECKNAME}' value: 'SPANLOSS-OCH NEND RCV' formulaid: A item_prototypes: - uuid: bf9b370d51084377a1e0d5a3c78353fb name: '{#PORTNAME} "{#CHECKNAME}"' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.562.68.10.1.1.1.1.1.6.{#SNMPINDEX}' key: 'optical.osc.spanloss[{#PORTNAME}.{#CHECKNAME}]' value_type: FLOAT units: db description: 'The span loss ont he receive fiber in db.' tags: - tag: Application value: 'Optical AMP/OSC' trigger_prototypes: - uuid: 2c477228c5864840ada7f736c9925272 expression: 'sum(/Ciena 6500 2/optical.osc.spanloss[{#PORTNAME}.{#CHECKNAME}],#2)=0 or last(/Ciena 6500 2/optical.osc.spanloss[{#PORTNAME}.{#CHECKNAME}],#1)<-44' name: '{#PORTNAME} has No Light' priority: HIGH description: 'The last two values for "{#CHECKNAME}" is 0. The check reports 0db when the OSC circuit cannot determine the spanloss. This would indicate a loss of light.' - uuid: 203da91ae906415abcc25583991f5725 name: 'Optical AMP Rx Discovery' type: SNMP_AGENT snmp_oid: 'discovery[{#PORTNAME},.1.3.6.1.4.1.562.68.10.1.1.1.1.1.3,{#CHECKNAME},.1.3.6.1.4.1.562.68.10.1.1.1.1.1.4,{#INDEX},.1.3.6.1.4.1.562.68.10.1.1.1.1.1.1]' key: optical.rx.discovery delay: 1d;wd1h13 filter: conditions: - macro: '{#CHECKNAME}' value: 'OPIN-OTS NEND NA' formulaid: A - macro: '{#PORTNAME}' value: '.*AMP.*' formulaid: B item_prototypes: - uuid: dca72b07a1214b31bf9a04f87eea7383 name: '{#PORTNAME} "Optical Receive Power" baseline' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.562.68.10.1.1.3.1.1.6.{#INDEX}.52' key: 'optical.baseline[{#PORTNAME}.OPIN]' delay: 5m value_type: FLOAT units: dbm description: 'The baseline set on the shelf. This can be re-initialized when needed via site manager.' tags: - tag: Application value: 'Optical AMP/OSC' - uuid: 7509803f25a94cda9d56b3d586825c45 name: '{#PORTNAME} "Optical Receive Power"' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.562.68.10.1.1.1.1.1.6.{#INDEX}.52' key: 'optical.rx[{#PORTNAME}.OPIN]' delay: 5m value_type: FLOAT units: dbm tags: - tag: Application value: 'Optical AMP/OSC' trigger_prototypes: - uuid: c865f1255114479cb1161bbd5f4f9589 expression: | ((last(/Ciena 6500 2/optical.rx[{#PORTNAME}.OPIN],#1)last(/Ciena 6500 2/optical.baseline[{#PORTNAME}.OPIN],#1)+{$OPTICAL_VARIANCE})) name: '{#PORTNAME} Optical Rx Power crossed baseline thresholds' priority: INFO description: 'The optical power level it more than {$OPTICAL_VARIANCE}db from the baseline value. This could be due to a new fiber event or the baselines may need to be reset. First verify the optical path then decide weather to reset the baselines. The baseline value can be reset in the PMs on the Ciena shelf.' - uuid: 577da428f7ab412695f7e41801628db1 name: 'Optical Transport Interface Discovery' type: SNMP_AGENT snmp_oid: 'discovery[{#IFTYPE},.1.3.6.1.2.1.2.2.1.3,{#IFADMINSTATUS},1.3.6.1.2.1.2.2.1.7,{#IFDESCR},1.3.6.1.2.1.2.2.1.2,{#CONNPRESENT},.1.3.6.1.2.1.31.1.1.1.17]' key: optical.transport.if.discovery delay: 1d;wd1h11 filter: evaltype: AND conditions: - macro: '{#IFTYPE}' value: '196' formulaid: C - macro: '{#IFADMINSTATUS}' value: '1' formulaid: B - macro: '{#CONNPRESENT}' value: '1' formulaid: A item_prototypes: - uuid: 299d5a91e8db41d0b6031a35098d447b name: '{#IFDESCR}: Admin Status' type: SNMP_AGENT snmp_oid: '1.3.6.1.2.1.2.2.1.7.{#SNMPINDEX}' key: 'net.if.status[ifAdminStatus.{#SNMPINDEX}]' delay: 5m description: 'The administrative status of the port.' valuemap: name: 'Interface Admin Status' tags: - tag: Application value: 'Optical Transport Interface' - uuid: 5f9d11953f86493d930e60cf8e98bd30 name: '{#IFDESCR}: Operational status' type: SNMP_AGENT snmp_oid: '1.3.6.1.2.1.2.2.1.8.{#SNMPINDEX}' key: 'net.if.status[ifOperStatus.{#SNMPINDEX}]' delay: 5m description: 'The operational status of the port.' valuemap: name: 'Interface Operational Status' tags: - tag: Application value: 'Optical Transport Interface' - uuid: 7f2fd081983f4d23a13db2cc2295f0ce name: '{#IFDESCR}: Optical Power Received' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.562.68.10.1.1.1.1.1.6.{#SNMPINDEX}.32' key: 'net.if.status[opr.och.nend.rcv.{#SNMPINDEX}]' delay: 5m value_type: FLOAT units: dbm description: 'The optical power received at this port in dbm.' tags: - tag: Application value: 'Optical Transport Interface' - uuid: 43f116eeea2341509f940bafb0e2aa06 name: '{#IFDESCR}: Optical Power Transmitted' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.562.68.10.1.1.1.1.1.6.{#SNMPINDEX}.34' key: 'net.if.status[opr.och.nend.trmt.{#SNMPINDEX}]' delay: 5m value_type: FLOAT units: dbm description: 'The optical power transmitted at this port in dbm.' tags: - tag: Application value: 'Optical Transport Interface' - uuid: 89a43a1a90494c5ca149753f9b3f4e72 name: '{#IFDESCR}: Post-FEC bit error rate' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.562.68.10.1.1.1.1.1.6.{#SNMPINDEX}.42' key: 'net.if.status[post.fec.ber.{#SNMPINDEX}]' delay: 5m trends: '0' value_type: CHAR description: 'Post-FEC bit error rate estimate, optical channel transport unit' tags: - tag: Application value: 'Optical Transport Interface' - uuid: 411023ebc3eb4b14ac07e7d82fa705e3 name: '{#IFDESCR}: Pre-FEC bit error rate' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.562.68.10.1.1.1.1.1.6.{#SNMPINDEX}.43' key: 'net.if.status[pre.fec.ber.{#SNMPINDEX}]' delay: 5m trends: '0' value_type: CHAR description: 'Pre-FEC bit error rate, optical channel transport unit' tags: - tag: Application value: 'Optical Transport Interface' - uuid: 530afbfb0ddd412f851aacb77f3db521 name: '{#IFDESCR}: Uncorrected FEC block' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.562.68.10.1.1.1.1.1.6.{#SNMPINDEX}.189' key: 'net.if.status[uncorrected.fec.block.{#SNMPINDEX}]' delay: 5m units: 'block error' description: 'Uncorrected FEC blocks, Optical Transport Unit.' tags: - tag: Application value: 'Optical Transport Interface' trigger_prototypes: - uuid: 49b379dbfd43498bbed9abbd651f40e5 expression: 'last(/Ciena 6500 2/net.if.status[ifOperStatus.{#SNMPINDEX}],#1)<>1 and last(/Ciena 6500 2/net.if.status[ifAdminStatus.{#SNMPINDEX}],#1:now-1s)=1' name: '{#IFDESCR} DOWN' priority: AVERAGE description: 'The interface status is not UP for this DWDM transport interface. This indicates the DWDM wave is down and could be a result of a fiber cut.' - uuid: 82dc067f9fd44520a70eb96a7d3b4235 name: 'Optical AMP Tx Discovery' type: SNMP_AGENT snmp_oid: 'discovery[{#PORTNAME},.1.3.6.1.4.1.562.68.10.1.1.1.1.1.3,{#CHECKNAME},.1.3.6.1.4.1.562.68.10.1.1.1.1.1.4,{#INDEX},.1.3.6.1.4.1.562.68.10.1.1.1.1.1.1]' key: optical.tx.discovery delay: 1d;wd1h12 filter: evaltype: AND conditions: - macro: '{#PORTNAME}' value: '.*AMP.*' formulaid: B - macro: '{#CHECKNAME}' value: 'ORL-OTS NEND NA' formulaid: A item_prototypes: - uuid: 0e2515f390d44b4bbb3c8b1d41a9c820 name: '{#PORTNAME} "Optical Transmit Power" baseline' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.562.68.10.1.1.3.1.1.6.{#INDEX}.55' key: 'optical.tx.baseline[{#PORTNAME}.OPOUT]' delay: 5m value_type: FLOAT units: dbm description: 'The baseline set on the shelf. This can be re-initialized when needed via site manager.' tags: - tag: Application value: 'Optical AMP/OSC' - uuid: afc74b3fde144fc9b5fcd5e393cf7bb4 name: '{#PORTNAME} "Optical Return Loss" baseline' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.562.68.10.1.1.3.1.1.6.{#INDEX}.51' key: 'optical.tx.baseline[{#PORTNAME}.ORL]' delay: 5m value_type: FLOAT units: dbm description: 'The baseline set on the shelf. This can be re-initialized when needed via site manager.' tags: - tag: Application value: 'Optical AMP/OSC' - uuid: 4364998794204d5e99c074c7e2876fbf name: '{#PORTNAME} "Optical Transmit Power"' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.562.68.10.1.1.1.1.1.6.{#INDEX}.55' key: 'optical.tx[{#PORTNAME}.OPOUT]' delay: 5m value_type: FLOAT units: dbm description: 'The optical transit power for this port in dbm.' tags: - tag: Application value: 'Optical AMP/OSC' - uuid: 758ff48a4172429a97b7a0f92dab1094 name: '{#PORTNAME} "Optical Return Loss"' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.562.68.10.1.1.1.1.1.6.{#INDEX}.51' key: 'optical.tx[{#PORTNAME}.ORL]' delay: 5m value_type: FLOAT units: dbm description: 'Optical Return Loss (ORL) is similar to SNR. The higher the ORL, the better.' tags: - tag: Application value: 'Optical AMP/OSC' trigger_prototypes: - uuid: b7b07a90e2ea4550ab2cfaee9564d113 expression: 'last(/Ciena 6500 2/optical.tx[{#PORTNAME}.ORL],#1)<30' name: '{#PORTNAME} LOW "Optical Return Loss"' priority: WARNING description: 'Optical Return Loss (ORL) is similar to SNR. The higher the ORL, the better. The minimum ORL is 30db. Anything lower than 30db indicates a fiber issue, such as a dirty connector or improper fiber mating.' trigger_prototypes: - uuid: 89645c9a0ea4496f8b7da786163d2eea expression: | (last(/Ciena 6500 2/optical.tx[{#PORTNAME}.ORL],#1)last(/Ciena 6500 2/optical.tx.baseline[{#PORTNAME}.ORL],#1)+{$OPTICAL_VARIANCE}) name: '{#PORTNAME} Optical Return Loss crossed baseline thresholds' priority: INFO description: 'The optical return loss it more than {$OPTICAL_VARIANCE}db from the baseline value. This could be due to a new fiber event or the baselines may need to be reset. First verify the optical path then decide weather to reset the baselines. The baseline value can be reset in the PMs on the Ciena shelf.' - uuid: ff63a9b94b5d4383bb60da1a6e95cf7c expression: | (last(/Ciena 6500 2/optical.tx[{#PORTNAME}.OPOUT],#1)last(/Ciena 6500 2/optical.tx.baseline[{#PORTNAME}.OPOUT],#1)+{$OPTICAL_VARIANCE}) name: '{#PORTNAME} Optical Tx Power crossed baseline thresholds' priority: INFO description: 'The optical power level is more than {$OPTICAL_VARIANCE}db from the baseline value. This could be due to a new fiber event or the baselines may need to be reset. First verify the optical path then decide weather to reset the baselines. The baseline value can be reset in the PMs on the Ciena shelf.' macros: - macro: '{$OPTICAL_VARIANCE}' value: '2' description: 'the allowed variance from baselines in db' - macro: '{$SNMP_COMMUNITY}' value: secret valuemaps: - uuid: 0eb33155cb6b4746a36805015a8dfeff name: 'Interface Admin Status' mappings: - value: '1' newvalue: up - value: '2' newvalue: down - value: '3' newvalue: testing - uuid: 81742c5796094f0997acdace5ed010cc name: 'Interface Operational Status' mappings: - value: '1' newvalue: up - value: '2' newvalue: down - value: '3' newvalue: testing