zabbix_export: version: '5.4' date: '2021-11-21T21:33:02Z' groups: - uuid: 7df96b18c230490a9a0a9e2307226338 name: Templates templates: - uuid: baec58aff2284e16ad3b07ba5701a8ec template: apc_nmc_2_ap9619 name: 'APC NMC 2 AP9619' description: | ## Overview This template was originaly created for the AP9619 card, but in version 2 now support more UPS's. Tested on: APC Symmetra PX40 3Phase UPS APC Smart-UPS VT 20kVA 3Phase UPS Smart-UPS RT 7500 RM XL and more... It gathers input and output values from all three phases. I tried to make it as universal as i could so it can be used with single phase ups's as well. I have disable some of the items on the template for the reason that my ups didn't support them, feel free to try them if they are supported by your UPS. Changelog V2: Added more items for single phase ups's and triggers. thanks, petroska ## Author petroska groups: - name: Templates items: - uuid: 654d3c07873f46a79230bebba0a4d40c name: 'Probe Humidity' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.318.1.1.10.2.3.2.1.6.1 key: iemStatusProbeCurrentHumid delay: 30s status: DISABLED units: '%' description: | The current humidity reading from the probe in percent relative humidity. tags: - tag: Application value: 'UPS Information' - uuid: 722cd60c3d3e4772adf6f266a692a169 name: 'Probe Temperature' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.318.1.1.10.2.3.2.1.4.1 key: iemStatusProbeCurrentTemp delay: 30s units: C description: | The current temperature reading from the probe displayed in the units shown in the 'iemStatusProbeTempUnits' OID (Celsius or Fahrenheit). tags: - tag: Application value: 'UPS Information' - uuid: 50e00486b5f2476685c7b944321c59d8 name: 'Probe Name' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.318.1.1.10.2.3.2.1.2.1 key: iemStatusProbeName delay: '3600' trends: '0' value_type: CHAR description: 'A descriptive name for the probe set by the user.' tags: - tag: Application value: 'UPS Information' - uuid: 880b8861ce3c4d2fb2eb8ad215f116fa name: 'Probe Status' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.318.1.1.10.2.3.2.1.3.1 key: iemStatusProbeStatus delay: '3600' valuemap: name: 'APC Probe Status' tags: - tag: Application value: 'UPS Information' - uuid: 51529c92aa01495d8d7ec011a28027a9 name: Location type: SNMP_AGENT snmp_oid: 1.3.6.1.2.1.1.6.0 key: sysLocation delay: '3600' trends: '0' value_type: CHAR tags: - tag: Application value: 'UPS Information' - uuid: f65b6e73bdd84b1b82b8a69cc9af2b32 name: 'Battery actual Volts' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.318.1.1.1.2.2.8.0 key: upsAdvBatteryActualVoltage delay: 30s units: V description: 'The actual battery bus voltage in Volts.' tags: - tag: Application value: 'UPS Battery' - uuid: d7b580543eae470dab8120e267b776c4 name: 'Battery Capacity' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.318.1.1.1.2.2.1.0 key: upsAdvBatteryCapacity delay: 30s units: '%' description: | The remaining battery capacity expressed in percent of full capacity. tags: - tag: Application value: 'UPS Battery' - uuid: eeb37a897ede4a51a1ba1c345e3d91ef name: 'Battery Amps' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.318.1.1.1.2.2.9.0 key: upsAdvBatteryCurrent delay: 30s units: A description: 'The battery current in Amps.' tags: - tag: Application value: 'UPS Battery' - uuid: b680d7854699492b8f52ad7ebabc8cf1 name: 'Battery nominal Volts' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.318.1.1.1.2.2.7.0 key: upsAdvBatteryNominalVoltage delay: 30s units: V description: 'The nominal battery voltage in Volts.' tags: - tag: Application value: 'UPS Battery' - uuid: d5303cafe7294cbf8f1355e466986181 name: 'Battery replace status' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.318.1.1.1.2.2.4.0 key: upsAdvBatteryReplaceIndicator delay: '3600' description: 'Indicates whether the UPS batteries need replacing.' valuemap: name: 'APC Battery Replacement Status' tags: - tag: Application value: 'UPS Battery' triggers: - uuid: 97bd08f3902a40ac914aa4b308c807c8 expression: last(/apc_nmc_2_ap9619/upsAdvBatteryReplaceIndicator)=4 name: 'Battery failed' priority: DISASTER - uuid: d8a48261b72d4eaca586a7e320b57a95 expression: last(/apc_nmc_2_ap9619/upsAdvBatteryReplaceIndicator)=6 name: 'Battery needs replacement' priority: HIGH - uuid: eb53e00618044e8b89f73ad2cd801004 expression: last(/apc_nmc_2_ap9619/upsAdvBatteryReplaceIndicator)=5 name: 'Battery overheat' priority: DISASTER - uuid: 67f6720e1808441283c6530520f434c9 expression: last(/apc_nmc_2_ap9619/upsAdvBatteryReplaceIndicator)=2 name: 'No battery' priority: HIGH - uuid: 56891066b30645b687776ab7c17966b6 name: 'Battery Runtime' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.318.1.1.1.2.2.3.0 key: upsAdvBatteryRunTimeRemaining delay: 30s units: s description: | The UPS battery run time remaining before battery exhaustion. preprocessing: - type: MULTIPLIER parameters: - '0.01' tags: - tag: Application value: 'UPS Battery' triggers: - uuid: e813f1bf4c204341a719ff9b5fe8c927 expression: last(/apc_nmc_2_ap9619/upsAdvBatteryRunTimeRemaining)<60 recovery_mode: RECOVERY_EXPRESSION recovery_expression: last(/apc_nmc_2_ap9619/upsAdvBatteryRunTimeRemaining)>60 name: 'UPS Runtime below 1 minute' priority: HIGH - uuid: 680ba71101c84a588fc8ea4fd11766e4 name: 'Battery Temperature' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.318.1.1.1.2.2.2.0 key: upsAdvBatteryTemperature delay: 30s units: C description: | The current internal UPS temperature expressed in Celsius. tags: - tag: Application value: 'UPS Battery' triggers: - uuid: 07c8ba85bd4f444291646ea1ecff55d1 expression: last(/apc_nmc_2_ap9619/upsAdvBatteryTemperature)>40 recovery_mode: RECOVERY_EXPRESSION recovery_expression: last(/apc_nmc_2_ap9619/upsAdvBatteryTemperature)<40 name: 'Battery temp above 40C' priority: HIGH - uuid: 5ca0e6f55ac641e5a1f0fd80a28fe5c3 name: 'Date of manufacture' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.318.1.1.1.1.2.2.0 key: upsAdvIdentDateOfManufacture delay: '3600' trends: '0' value_type: CHAR description: 'The date when the UPS was manufactured in mm/dd/yy (or yyyy) format.' tags: - tag: Application value: 'UPS Information' - uuid: d1f12d9e28924da499b207fa36e1e9b9 name: 'Firmware Revision' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.318.1.1.1.1.2.1.0 key: upsAdvIdentFirmwareRevision delay: '3600' trends: '0' value_type: CHAR description: 'The firmware revision of the UPS system''s microprocessor.' tags: - tag: Application value: 'UPS Information' - uuid: 3f5b0424bbef4b44928ebf2f3fb99c74 name: 'Input Frequency' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.318.1.1.1.3.2.4.0 key: upsAdvInputFrequency delay: 30s units: Hz description: 'The current input frequency to the UPS system in Hz.' tags: - tag: Application value: 'UPS Input [1Phase]' - uuid: e96f9c06dad44076b109c1fcadee9613 name: 'Latest cause for switching to battery power' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.318.1.1.1.3.2.5.0 key: upsAdvInputLineFailCause delay: 60s description: | The reason for the occurrence of the last transfer to UPS battery power. The variable is set to: - noTransfer(1) -- if there is no transfer yet. - highLineVoltage(2) -- if the transfer to battery is caused by an over voltage greater than the high transfer voltage. - brownout(3) -- if the duration of the outage is greater than five seconds and the line voltage is between 40% of the rated output voltage and the low transfer voltage. - blackout(4) -- if the duration of the outage is greater than five seconds and the line voltage is between 40% of the rated output voltage and ground. - smallMomentarySag(5) -- if the duration of the outage is less than five seconds and the line voltage is between 40% of the rated output voltage and the low transfer voltage. - deepMomentarySag(6) -- if the duration of the outage is less than five seconds and the line voltage is between 40% of the rated output voltage and ground. The variable is set to - smallMomentarySpike(7) -- if the line failure is caused by a rate of change of input voltage less than ten volts per cycle. - largeMomentarySpike(8) -- if the line failure is caused by a rate of change of input voltage greater than ten volts per cycle. - selfTest(9) -- if the UPS was commanded to do a self test. - rateOfVoltageChange(10) -- if the failure is due to the rate of change of the line voltage. valuemap: name: 'APC Input Line Fail Cause' tags: - tag: Application value: 'UPS Input [1Phase]' - uuid: d6cfaff5d9fa4610b6d0de099fbab43c name: 'Input Voltage' type: SNMP_AGENT snmp_oid: .1.3.6.1.4.1.318.1.1.1.3.2.1.0 key: upsAdvInputLineVoltage delay: 30s units: V description: 'The current utility line voltage in VAC.' tags: - tag: Application value: 'UPS Input [1Phase]' triggers: - uuid: e2883107936c4044bd5621e5fbc7d75b expression: last(/apc_nmc_2_ap9619/upsAdvInputLineVoltage)<100 recovery_mode: RECOVERY_EXPRESSION recovery_expression: last(/apc_nmc_2_ap9619/upsAdvInputLineVoltage)>220 name: 'Input voltage failed' priority: DISASTER - uuid: f1af7551e4c24cebb15601eb4df03af1 name: 'Output Load Current' type: SNMP_AGENT snmp_oid: .1.3.6.1.4.1.318.1.1.1.4.2.4.0 key: upsAdvOutputCurrent delay: 30s units: A tags: - tag: Application value: 'UPS Output [1Phase]' - uuid: 57db2b55d8ad47918ed28c009522a3db name: 'Output Load' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.318.1.1.1.4.2.3.0 key: upsAdvOutputLoad delay: 30s units: '%' description: | The current UPS load expressed in percent of rated capacity. tags: - tag: Application value: 'UPS Output [1Phase]' - uuid: 7527170104ce45bea470d216b9011027 name: 'Output Voltage' type: SNMP_AGENT snmp_oid: .1.3.6.1.4.1.318.1.1.1.4.2.1.0 key: upsAdvOutputVoltage delay: 30s units: V tags: - tag: Application value: 'UPS Output [1Phase]' - uuid: 2ab656441e46478d8bfdd0c763059df4 name: 'Battery total DC current' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.318.1.1.1.2.2.10.0 key: upsAdvTotalDCCurrent delay: 30s units: A description: 'The total DC current in Amps.' tags: - tag: Application value: 'UPS Battery' - uuid: e1cbfc197b254ca48140d38bb6f4677a name: 'Battery Status' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.318.1.1.1.2.1.1.0 key: upsBasicBatteryStatus delay: 30s description: | The status of the UPS batteries. A batteryLow(3) value indicates the UPS will be unable to sustain the current load, and its services will be lost if power is not restored. The amount of run time in reserve at the time of low battery can be configured by the upsAdvConfigLowBatteryRunTime. A batteryInFaultCondition(4)value indicates that a battery installed has an internal error condition. valuemap: name: 'APC Battery Status' tags: - tag: Application value: 'UPS Battery' triggers: - uuid: 96e983054a0d459f9889c0ae97a90187 expression: last(/apc_nmc_2_ap9619/upsBasicBatteryStatus)=3 recovery_mode: RECOVERY_EXPRESSION recovery_expression: last(/apc_nmc_2_ap9619/upsBasicBatteryStatus)=2 name: 'UPS batteries low' priority: DISASTER - uuid: 7c74e53e7f704bda9e0e1450ec513863 expression: last(/apc_nmc_2_ap9619/upsBasicBatteryStatus)=4 recovery_mode: RECOVERY_EXPRESSION recovery_expression: last(/apc_nmc_2_ap9619/upsBasicBatteryStatus)=2 name: 'UPS battery fault condition' priority: HIGH - uuid: 37bbf479b841467aaa877d2a075fe72b name: 'Time on battery' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.318.1.1.1.2.1.2.0 key: upsBasicBatteryTimeOnBattery delay: 30s trends: '0' value_type: TEXT description: | The elapsed time since the UPS has switched to battery power. tags: - tag: Application value: 'UPS Battery' triggers: - uuid: 010b34d355aa4097a5b9fbd3ba9ff0bf expression: last(/apc_nmc_2_ap9619/upsBasicBatteryTimeOnBattery)>60 recovery_mode: RECOVERY_EXPRESSION recovery_expression: last(/apc_nmc_2_ap9619/upsBasicBatteryTimeOnBattery)<=0 name: 'UPS on battery for 1 minute, H/Z should be on by now' priority: DISASTER - uuid: 521baf96134d4003a1187d0af4959e4d expression: last(/apc_nmc_2_ap9619/upsBasicBatteryTimeOnBattery)>120 recovery_mode: RECOVERY_EXPRESSION recovery_expression: last(/apc_nmc_2_ap9619/upsBasicBatteryTimeOnBattery)<=0 name: 'UPS on battery for 2 minutes, H/Z should be on by now' priority: DISASTER - uuid: 88e32939d41c44b2bca3d743bb3cf0e7 expression: last(/apc_nmc_2_ap9619/upsBasicBatteryTimeOnBattery)>0 recovery_mode: RECOVERY_EXPRESSION recovery_expression: last(/apc_nmc_2_ap9619/upsBasicBatteryTimeOnBattery)<=0 name: 'UPS on battery power' priority: DISASTER - uuid: 75373bb19f5140e7b363b10716ae02a5 name: Model type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.318.1.1.1.1.1.1.0 key: upsBasicIdentModel delay: '3600' trends: '0' value_type: CHAR description: 'The UPS model name (e.g. ''APC Smart-UPS 600'').' tags: - tag: Application value: 'UPS Information' - uuid: 415f707cbe2145bc948229888d244d4d name: Name type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.318.1.1.1.1.1.2.0 key: upsBasicIdentName delay: '3600' trends: '0' value_type: CHAR description: | An 8 byte ID string identifying the UPS. This object can be set by the administrator. tags: - tag: Application value: 'UPS Information' - uuid: b87a73e83e1e4835be2f83c063ad2edc name: 'Internal temperature' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.318.1.1.1.4.1.4 key: upsBasicSystemInternalTemperature delay: 30s units: C description: 'The actual internal temperature of the UPS system in Celsius.' tags: - tag: Application value: 'UPS Information' - uuid: f7b37e22d2c04b2ebe53b9222d024e43 name: 'Battery actual Volts [HighPrec]' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.318.1.1.1.2.3.4.0 key: upsHighPrecBatteryActualVoltage delay: 30s value_type: FLOAT units: V description: 'The actual battery bus voltage in tenths of Volts.' preprocessing: - type: MULTIPLIER parameters: - '0.1' tags: - tag: Application value: 'UPS Battery' - uuid: 16732d0ed28141ae8ff91695ed53cf44 name: 'Battery Capacity [HighPrec]' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.318.1.1.1.2.3.1.0 key: upsHighPrecBatteryCapacity delay: 30s value_type: FLOAT units: '%' description: | The remaining battery capacity expressed in tenths of percent of full capacity. preprocessing: - type: MULTIPLIER parameters: - '0.1' tags: - tag: Application value: 'UPS Battery' triggers: - uuid: 77df2fb05cbe41e48675ebf82b3380dc expression: last(/apc_nmc_2_ap9619/upsHighPrecBatteryCapacity)<10 recovery_mode: RECOVERY_EXPRESSION recovery_expression: last(/apc_nmc_2_ap9619/upsHighPrecBatteryCapacity)>10 name: 'Battery capacity below 10%' priority: HIGH - uuid: ae9cb18d78f4404bbb2e9dd057662128 expression: last(/apc_nmc_2_ap9619/upsHighPrecBatteryCapacity)<20 recovery_mode: RECOVERY_EXPRESSION recovery_expression: last(/apc_nmc_2_ap9619/upsHighPrecBatteryCapacity)>20 name: 'Battery capacity below 20%' priority: HIGH - uuid: ae1a84c9433841758df22f92f1bec53a expression: last(/apc_nmc_2_ap9619/upsHighPrecBatteryCapacity)<30 recovery_mode: RECOVERY_EXPRESSION recovery_expression: last(/apc_nmc_2_ap9619/upsHighPrecBatteryCapacity)>30 name: 'Battery capacity below 30%' priority: HIGH - uuid: 52c117a9777e4dc4ac9c32d617304602 expression: last(/apc_nmc_2_ap9619/upsHighPrecBatteryCapacity)<40 recovery_mode: RECOVERY_EXPRESSION recovery_expression: last(/apc_nmc_2_ap9619/upsHighPrecBatteryCapacity)>40 name: 'Battery capacity below 40%' priority: HIGH - uuid: c59a97181dd34cbabba9f8a6118527e4 expression: last(/apc_nmc_2_ap9619/upsHighPrecBatteryCapacity)<50 recovery_mode: RECOVERY_EXPRESSION recovery_expression: last(/apc_nmc_2_ap9619/upsHighPrecBatteryCapacity)>50 name: 'Battery capacity below 50%' priority: HIGH - uuid: 0054e707865a4639a979d96ce7e3a984 name: 'Battery Amps [HighPrec]' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.318.1.1.1.2.3.5.0 key: upsHighPrecBatteryCurrent delay: 30s units: A description: 'The battery current in tenths of Amps.' tags: - tag: Application value: 'UPS Battery' - uuid: 69b36af24cdd463db5898e08207801fc name: 'Battery nominal Volts [HighPrec]' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.318.1.1.1.2.3.3.0 key: upsHighPrecBatteryNominalVoltage delay: 30s value_type: FLOAT units: V preprocessing: - type: MULTIPLIER parameters: - '0.1' tags: - tag: Application value: 'UPS Battery' - uuid: a49516d715514746a938616de9ba0a11 name: 'Battery Temperature [HighPrec]' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.318.1.1.1.2.3.2.0 key: upsHighPrecBatteryTemperature delay: 30s status: DISABLED value_type: FLOAT units: C description: | The current internal UPS temperature expressed in tenths of degrees Celsius. preprocessing: - type: MULTIPLIER parameters: - '0.1' tags: - tag: Application value: 'UPS Battery' - uuid: b3e0fae710614601bdaa25046ec5222d name: 'Input Frequency [HighPrec]' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.318.1.1.1.3.3.4.0 key: upsHighPrecInputFrequency delay: 30s value_type: FLOAT units: Hz preprocessing: - type: MULTIPLIER parameters: - '0.1' tags: - tag: Application value: 'UPS Input [1Phase]' - uuid: 6748a117ba864d10a496fb8141669ff2 name: 'Input Voltage [HighPrec]' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.318.1.1.1.3.3.1.0 key: upsHighPrecInputLineVoltage delay: 30s value_type: FLOAT units: V description: 'The current utility line voltage in tenths of VAC.' preprocessing: - type: MULTIPLIER parameters: - '0.1' tags: - tag: Application value: 'UPS Input [1Phase]' - uuid: a3e30c1bf3c34b95a290466324a5764d name: 'Battery total DC current [HighPrec]' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.318.1.1.1.2.3.6.0 key: upsHighPrecTotalDCCurrent delay: 30s units: A description: | The total DC current in tenths of Amps. not always supported tags: - tag: Application value: 'UPS Battery' - uuid: 457bba16c25b4118adfaf26a56add058 name: 'Input Current L1' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.318.1.1.1.9.2.3.1.6.1.1.1 key: upsPhaseInputCurrentL1 delay: 30s units: A description: | The input current in 0.1 amperes, or -1 if it's unsupported by this UPS. preprocessing: - type: MULTIPLIER parameters: - '0.1' tags: - tag: Application value: 'UPS Input [3Phase]' - uuid: 047ca6fb73f34807b8ab59b1029b92d8 name: 'Input Current L2' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.318.1.1.1.9.2.3.1.6.1.1.2 key: upsPhaseInputCurrentL2 delay: 30s units: A description: | The input current in 0.1 amperes, or -1 if it's unsupported by this UPS. preprocessing: - type: MULTIPLIER parameters: - '0.1' tags: - tag: Application value: 'UPS Input [3Phase]' - uuid: 3df3849dd89a4b6abc80bb54b44b1f4c name: 'Input Current L3' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.318.1.1.1.9.2.3.1.6.1.1.3 key: upsPhaseInputCurrentL3 delay: 30s units: A description: | The input current in 0.1 amperes, or -1 if it's unsupported by this UPS. preprocessing: - type: MULTIPLIER parameters: - '0.1' tags: - tag: Application value: 'UPS Input [3Phase]' - uuid: 1a2643a01a9448e8a6ff58a3f02a6438 name: 'Input Voltage L1' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.318.1.1.1.9.2.3.1.3.1.1.1 key: upsPhaseInputVoltageL1 delay: 30s units: V description: | The input voltage in VAC, or -1 if it's unsupported by this UPS. tags: - tag: Application value: 'UPS Input [3Phase]' triggers: - uuid: d5447b00abdb487bb15ce52d3a34df26 expression: last(/apc_nmc_2_ap9619/upsPhaseInputVoltageL1)<100 recovery_mode: RECOVERY_EXPRESSION recovery_expression: last(/apc_nmc_2_ap9619/upsPhaseInputVoltageL1)>220 name: 'Input voltage on phase 1 failed' priority: DISASTER - uuid: d8ea14275e7c46d3b9ef0d31425808da name: 'Input Voltage L2' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.318.1.1.1.9.2.3.1.3.1.1.2 key: upsPhaseInputVoltageL2 delay: 30s units: V description: | The input voltage in VAC, or -1 if it's unsupported by this UPS. tags: - tag: Application value: 'UPS Input [3Phase]' triggers: - uuid: a48c4c499a8f4cb0a4fb94f9477c0eca expression: last(/apc_nmc_2_ap9619/upsPhaseInputVoltageL2)<100 recovery_mode: RECOVERY_EXPRESSION recovery_expression: last(/apc_nmc_2_ap9619/upsPhaseInputVoltageL2)>220 name: 'Input voltage on phase 2 failed' priority: DISASTER - uuid: 5f403c2372b445eaa70b798ca7eacceb name: 'Input Voltage L3' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.318.1.1.1.9.2.3.1.3.1.1.3 key: upsPhaseInputVoltageL3 delay: 30s units: V description: | The input voltage in VAC, or -1 if it's unsupported by this UPS. tags: - tag: Application value: 'UPS Input [3Phase]' triggers: - uuid: 2f08da303ea843c9b50b4760fa831ce1 expression: last(/apc_nmc_2_ap9619/upsPhaseInputVoltageL3)<100 recovery_mode: RECOVERY_EXPRESSION recovery_expression: last(/apc_nmc_2_ap9619/upsPhaseInputVoltageL3)>220 name: 'Input voltage on phase 3 failed' priority: DISASTER - uuid: be2e8635281c4578aa4404d02378e0ee name: 'Output Current L1' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.318.1.1.1.9.3.3.1.4.1.1.1 key: upsPhaseOutputCurrentL1 delay: 30s units: A description: | The output current in 0.1 amperes drawn by the load on the UPS, or -1 if it's unsupported by this UPS. preprocessing: - type: MULTIPLIER parameters: - '0.1' tags: - tag: Application value: 'UPS Output [3Phase]' - uuid: 9c3bddf4b03544c498e34efc524774cf name: 'Output Current L2' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.318.1.1.1.9.3.3.1.4.1.1.2 key: upsPhaseOutputCurrentL2 delay: 30s units: A description: | The output current in 0.1 amperes drawn by the load on the UPS, or -1 if it's unsupported by this UPS. preprocessing: - type: MULTIPLIER parameters: - '0.1' tags: - tag: Application value: 'UPS Output [3Phase]' - uuid: e6417fea11c24efe909862c7a249d17f name: 'Output Current L3' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.318.1.1.1.9.3.3.1.4.1.1.3 key: upsPhaseOutputCurrentL3 delay: 30s units: A description: | The output current in 0.1 amperes drawn by the load on the UPS, or -1 if it's unsupported by this UPS. preprocessing: - type: MULTIPLIER parameters: - '0.1' tags: - tag: Application value: 'UPS Output [3Phase]' - uuid: a03ba9a1977242a69d257fa818ec3dd5 name: 'Output Load L1' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.318.1.1.1.9.3.3.1.7.1.1.1 key: upsPhaseOutputLoadL1 delay: 30s units: VA description: | The output load in VA, or -1 if it's unsupported by this UPS. tags: - tag: Application value: 'UPS Output [3Phase]' - uuid: 45b4841e97204be287d76f4fef6e3909 name: 'Output Load L2' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.318.1.1.1.9.3.3.1.7.1.1.2 key: upsPhaseOutputLoadL2 delay: 30s units: VA description: | The output load in VA, or -1 if it's unsupported by this UPS. tags: - tag: Application value: 'UPS Output [3Phase]' - uuid: 072aea366d294cf69b1219ec0daa8b61 name: 'Output Load L3' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.318.1.1.1.9.3.3.1.7.1.1.3 key: upsPhaseOutputLoadL3 delay: 30s units: VA description: | The output load in VA, or -1 if it's unsupported by this UPS. tags: - tag: Application value: 'UPS Output [3Phase]' - uuid: 648fbab1b2d44f29989623f4d6bd1b69 name: 'Output Phase capacity L1' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.318.1.1.1.9.3.3.1.16.1.1.1 key: upsPhaseOutputPercentPowerL1 delay: 30s units: '%' description: | The percentage of the UPS power capacity in Watts at redundancy @ (n + x) presently being used on this output phase, or -1 if it's unsupported by this UPS. tags: - tag: Application value: 'UPS Output [3Phase]' triggers: - uuid: 953d5fba38ff470ca83302d8904a0c16 expression: last(/apc_nmc_2_ap9619/upsPhaseOutputPercentPowerL1)>50 recovery_mode: RECOVERY_EXPRESSION recovery_expression: last(/apc_nmc_2_ap9619/upsPhaseOutputPercentPowerL1)<50 name: 'Phase 1 output capcity above 50%' priority: HIGH - uuid: a132d2564230478cbc2a7d3ae33f13dc name: 'Output Phase capacity L2' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.318.1.1.1.9.3.3.1.16.1.1.2 key: upsPhaseOutputPercentPowerL2 delay: 30s units: '%' description: | The percentage of the UPS power capacity in Watts at redundancy @ (n + x) presently being used on this output phase, or -1 if it's unsupported by this UPS. tags: - tag: Application value: 'UPS Output [3Phase]' triggers: - uuid: 63e307a60e2e4dc5b3f220d09ada48c1 expression: last(/apc_nmc_2_ap9619/upsPhaseOutputPercentPowerL2)>50 recovery_mode: RECOVERY_EXPRESSION recovery_expression: last(/apc_nmc_2_ap9619/upsPhaseOutputPercentPowerL2)<50 name: 'Phase 2 output capcity above 50%' priority: HIGH - uuid: 0ef8477a50944762b45637c3a0965f8b name: 'Output Phase capacity L3' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.318.1.1.1.9.3.3.1.16.1.1.3 key: upsPhaseOutputPercentPowerL3 delay: 30s units: '%' description: | The percentage of the UPS power capacity in Watts at redundancy @ (n + x) presently being used on this output phase, or -1 if it's unsupported by this UPS. tags: - tag: Application value: 'UPS Output [3Phase]' triggers: - uuid: 87cab55374c145d6ae78c138c6f72ab3 expression: last(/apc_nmc_2_ap9619/upsPhaseOutputPercentPowerL3)>50 recovery_mode: RECOVERY_EXPRESSION recovery_expression: last(/apc_nmc_2_ap9619/upsPhaseOutputPercentPowerL3)<50 name: 'Phase 3 output capcity above 50%' priority: HIGH - uuid: ecb8a1cfc21644e98df50d5af85f5721 name: 'Output Power L1' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.318.1.1.1.9.3.3.1.13.1.1.1 key: upsPhaseOutputPowerL1 delay: 30s status: DISABLED units: W description: | The output power in Watts, or -1 if it's unsupported by this UPS. tags: - tag: Application value: 'UPS Output [3Phase]' - uuid: 656ced5372504600bb647719aebe7b5b name: 'Output Power L2' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.318.1.1.1.9.3.3.1.13.1.1.2 key: upsPhaseOutputPowerL2 delay: 30s status: DISABLED units: W tags: - tag: Application value: 'UPS Output [3Phase]' - uuid: 99eabebac45d4d30bc498df1c75ba73c name: 'Output Power L3' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.318.1.1.1.9.3.3.1.13.1.1.3 key: upsPhaseOutputPowerL3 delay: 30s status: DISABLED units: W description: | The output power in Watts, or -1 if it's unsupported by this UPS. tags: - tag: Application value: 'UPS Output [3Phase]' - uuid: 30dc20c874ee48d88f3c1e1baad79937 name: 'Output Voltage L1' type: SNMP_AGENT snmp_oid: .1.3.6.1.4.1.318.1.1.1.9.3.3.1.3.1.1.1 key: upsPhaseOutputVoltageL1 delay: 30s units: VAC description: | The output voltage in VAC, or -1 if it's unsupported by this UPS. tags: - tag: Application value: 'UPS Output [3Phase]' - uuid: f88171bf48724d7f81e333a6d2ca2a53 name: 'Output Voltage L2' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.318.1.1.1.9.3.3.1.3.1.1.2 key: upsPhaseOutputVoltageL2 delay: 30s units: VAC description: | The output voltage in VAC, or -1 if it's unsupported by this UPS. tags: - tag: Application value: 'UPS Output [3Phase]' - uuid: 9c48b6e6e15b4f3194fa9a67cda970f2 name: 'Output Voltage L3' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.318.1.1.1.9.3.3.1.3.1.1.3 key: upsPhaseOutputVoltageL3 delay: 30s units: VAC description: | The output voltage in VAC, or -1 if it's unsupported by this UPS. tags: - tag: Application value: 'UPS Output [3Phase]' valuemaps: - uuid: 9f6d111bfe5641e688a1ad4867bce008 name: 'APC Battery Replacement Status' mappings: - value: '1' newvalue: unknown - value: '2' newvalue: notInstalled - value: '3' newvalue: ok - value: '4' newvalue: failed - value: '5' newvalue: highTemperature - value: '6' newvalue: replaceImmediately - value: '7' newvalue: lowCapacity - uuid: ec262fd1871847aea36ad90381f5efad name: 'APC Battery Status' mappings: - value: '1' newvalue: unknown - value: '2' newvalue: batteryNormal - value: '3' newvalue: batteryLow - value: '4' newvalue: batteryInFaultCondition - uuid: b17a4be8637e4e6ba9faeec6f0dc8353 name: 'APC Input Line Fail Cause' mappings: - value: '1' newvalue: noTransfe - value: '2' newvalue: highLineVoltage - value: '3' newvalue: brownout - value: '4' newvalue: blackout - value: '5' newvalue: smallMomentarySag - value: '6' newvalue: deepMomentarySag - value: '7' newvalue: smallMomentarySpike - value: '8' newvalue: largeMomentarySpike - value: '9' newvalue: selfTest - value: '10' newvalue: rateOfVoltageChange - uuid: 56992ca754ac4d1385564e612ddbc83c name: 'APC Probe Status' mappings: - value: '1' newvalue: Disconnected - value: '2' newvalue: Connected graphs: - uuid: 75651068aea84e039d4ab17ecf8c13bf name: 'Input Volts and Frequency' width: '1200' graph_items: - color: 1A7C11 item: host: apc_nmc_2_ap9619 key: upsAdvInputFrequency - sortorder: '1' color: F63100 item: host: apc_nmc_2_ap9619 key: upsAdvInputLineVoltage - sortorder: '2' color: 2774A4 item: host: apc_nmc_2_ap9619 key: upsPhaseInputVoltageL1 - sortorder: '3' color: A54F10 item: host: apc_nmc_2_ap9619 key: upsPhaseInputVoltageL2 - sortorder: '4' color: FC6EA3 item: host: apc_nmc_2_ap9619 key: upsPhaseInputVoltageL3 - uuid: a84e327ccb7346e7a97ff7ecb4e59c88 name: 'Output Load and Runtime' width: '1200' graph_items: - color: 1A7C11 item: host: apc_nmc_2_ap9619 key: upsAdvBatteryRunTimeRemaining - sortorder: '1' color: F63100 item: host: apc_nmc_2_ap9619 key: upsAdvOutputLoad