zabbix_export: version: '6.0' date: '2021-11-21T21:40:00Z' groups: - uuid: 7df96b18c230490a9a0a9e2307226338 name: Templates templates: - uuid: eb8d1b2535cf463188ca0639db65bd64 template: Powerware9390-Pt-Br name: Powerware9390-Pt-Br description: | ## Overview Portuguese items description, graphs names and application, but SNMP keys in English. Input, output, load, battery, external probe, UPS state. ## Author Nilson Espurio groups: - name: Templates items: - uuid: b7b39c6a1b3d4c8e9d3854558aaf2707 name: 'Bateria Atual' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.534.1.2.3.0 key: batcur delay: '30' history: 14d trends: 30d value_type: FLOAT units: A tags: - tag: Application value: Bateria - uuid: 8bbd0537d41f40949fddfa462d73d7ca name: 'ICMP Ping' type: SIMPLE snmp_oid: interfaces.ifTable.ifEntry.ifInOctets.1 key: icmpping delay: '30' history: 14d trends: 30d tags: - tag: Application value: 'Status da UPS' triggers: - uuid: 3fd66fce01684818b13328fa28b321c8 expression: 'max(/Powerware9390-Pt-Br/icmpping,300s)<>1' name: '{HOSTNAME} está inacecível via Rede' priority: HIGH - uuid: 6fe9eb53f0514f35b6b9e3b812748f8d name: 'Número de Estados Tipo Alarme' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.534.1.7.1.0 key: xupsAlarms delay: '30' history: 14d trends: 30d units: PCs tags: - tag: Application value: 'Status da UPS' triggers: - uuid: 018ac4e8310f4ea89aeb9bb5c2dcdc01 expression: last(/Powerware9390-Pt-Br/xupsAlarms)<>0 name: '"Alarmes" on {HOSTNAME}' status: DISABLED priority: HIGH - uuid: 3f7dbf98d2fc4235845e696933aa27e5 name: 'Capacidade Bateria' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.534.1.2.4.0 key: xupsBatCapacity delay: '30' history: 14d trends: 30d units: '%' tags: - tag: Application value: Bateria - uuid: 9541a53dec764228814e44a33bef57e3 name: 'Tempo Bateria Restante' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.534.1.2.1.0 key: xupsBatTimeRemaining delay: '30' history: 14d trends: 30d value_type: FLOAT units: min preprocessing: - type: MULTIPLIER parameters: - '0.016666667' tags: - tag: Application value: Bateria - uuid: fbc2f726cb124a518d875260eb498b53 name: 'Voltagem da Bateria' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.534.1.2.2.0 key: xupsBatVoltage delay: '30' history: 14d trends: 30d units: V tags: - tag: Application value: Bateria - uuid: 6e1dfedb99764f958a0c400b02f3db7e name: 'Frequência do Byppas' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.534.1.5.1.0 key: xupsBypassFrequency delay: '30' history: 14d trends: 30d units: Hz preprocessing: - type: MULTIPLIER parameters: - '0.1' tags: - tag: Application value: Bypass - uuid: 838952ccc3c8472a9279a83de84f3f69 name: 'Tensão de Byppas A-N' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.534.1.5.3.1.2.1 key: xupsBypassVoltagea delay: '30' history: 14d trends: 30d units: V tags: - tag: Application value: Bypass - uuid: 752a3a6175ab42e5a24423b5fe02e0b6 name: 'Tensão de Byppas B-N' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.534.1.5.3.1.2.2 key: xupsBypassVoltageb delay: '30' history: 14d trends: 30d units: V tags: - tag: Application value: Bypass - uuid: a81146dbc482422f871820a5393f281a name: 'Tensão de Byppas C-N' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.534.1.5.3.1.2.3 key: xupsBypassVoltagec delay: '30' history: 14d trends: 30d units: V tags: - tag: Application value: Bypass - uuid: 74f4e1414cff4ef69bf3a714ae8f4fb3 name: 'Humidade Sensor Remoto' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.534.1.6.6.0 key: xupsEnvRemoteHumidity delay: '30' history: 14d trends: 30d units: '%' tags: - tag: Application value: 'Status da UPS' triggers: - uuid: adff50e674af473098e49381e5872854 expression: last(/Powerware9390-Pt-Br/xupsEnvRemoteHumidity)>75 name: 'Humidade Relativa na UPS não está normal' priority: HIGH - uuid: db5b6dcbc1d74b539fb9e6d7ee3518da name: 'Temperatura Sensor Remoto' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.534.1.6.5.0 key: xupsEnvRemoteTemp delay: '30' history: 14d trends: 30d units: C tags: - tag: Application value: 'Status da UPS' triggers: - uuid: f97a144344564ff383328e4f8b4b4ae9 expression: last(/Powerware9390-Pt-Br/xupsEnvRemoteTemp)>26 name: 'Temperatura na UPS não está normal' priority: HIGH - uuid: 275b899af5144638b03f6a549e7529ed name: 'Corrente de Entrada A' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.534.1.3.4.1.3.1 key: xupsInputCurrenta delay: '30' history: 14d trends: 30d units: А tags: - tag: Application value: Entrada - uuid: cd9f4d7d819c416683a2f43d5ee43a26 name: 'Corrente de Entrada B' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.534.1.3.4.1.3.2 key: xupsInputCurrentb delay: '30' history: 14d trends: 30d units: А tags: - tag: Application value: Entrada - uuid: f0070f94642a46709a472acf2bea76df name: 'Corrente de Entrada C' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.534.1.3.4.1.3.3 key: xupsInputCurrentc delay: '30' history: 14d trends: 30d units: А tags: - tag: Application value: Entrada - uuid: 61a02dce88d94cd181e9bf65b3a21dd7 name: 'Frequência de Entrada' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.534.1.3.1.0 key: xupsInputFrequency delay: '30' history: 14d trends: 30d units: Hz preprocessing: - type: MULTIPLIER parameters: - '0.1' tags: - tag: Application value: Entrada - uuid: 67962006dcf348f8b2254b1f60880dd8 name: 'Número de Frequência ou Tensão Anormais' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.534.1.3.2.0 key: xupsInputLineBads delay: '30' history: 14d trends: 30d tags: - tag: Application value: 'Status da UPS' - uuid: da86f2e9019d4433b35f77a3ae014d10 name: 'Status de Entrado do No-break' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.534.1.3.5.0 key: xupsInputSource delay: '30' history: 14d trends: 30d tags: - tag: Application value: 'Status da UPS' triggers: - uuid: 1278daaadf0f4ce5b45fab8ae3128e2f expression: last(/Powerware9390-Pt-Br/xupsInputSource)=4 name: '{HOSTNAME} está em Bypass' priority: AVERAGE - uuid: 1bb8e6190c744460ad0dff87146b0807 expression: last(/Powerware9390-Pt-Br/xupsInputSource)<3 name: '{HOSTNAME} falha na fonte de Entrada' priority: HIGH - uuid: bdd9db032fdf453bab9189bf913553f0 name: 'Tensão Entrada A-N' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.534.1.3.4.1.2.1 key: xupsInputVoltage delay: '30' history: 14d trends: 30d units: V tags: - tag: Application value: Entrada - uuid: 556aa51261474944aef58e5b0d4326c8 name: 'Tensão de Entrada B-N' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.534.1.3.4.1.2.2 key: xupsInputVoltageb delay: '30' history: 14d trends: 30d units: V tags: - tag: Application value: Entrada - uuid: ce5afc5f0393488c9f2c71233208df98 name: 'Tensão de Entrada C-N' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.534.1.3.4.1.2.3 key: xupsInputVoltagec delay: '30' history: 14d trends: 30d units: V tags: - tag: Application value: Entrada - uuid: 2acb7bae6e8541dc8fc4a7927bbc22d6 name: 'Corrente de Saída A' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.534.1.4.4.1.3.1 key: xupsOutputCurrenta delay: '30' history: 14d trends: 30d units: А tags: - tag: Application value: Saída - uuid: f4949ef408b3499bbf00ceffb3cd2367 name: 'Corrente de Saída B' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.534.1.4.4.1.3.2 key: xupsOutputCurrentb delay: '30' history: 14d trends: 30d units: А tags: - tag: Application value: Saída - uuid: 224b71fd297642af9f2f2a133c1470be name: 'Corrente de Saída C' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.534.1.4.4.1.3.3 key: xupsOutputCurrentc delay: '30' history: 14d trends: 30d units: А tags: - tag: Application value: Saída - uuid: 52c4b11b363047d1b3fffe8a43b1479b name: 'Frequência de Saída' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.534.1.4.2.0 key: xupsOutputFrequency delay: '30' history: 14d trends: 30d value_type: FLOAT units: Hz preprocessing: - type: MULTIPLIER parameters: - '0.1' tags: - tag: Application value: Saída - uuid: 96cb62fc29e54423a72325fc26f64eeb name: 'Status da UPS' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.534.1.4.5.0 key: xupsOutputSource delay: '30' history: 14d trends: 30d tags: - tag: Application value: 'Status da UPS' triggers: - uuid: 51a390a6d08b4565b71683502a367e96 expression: last(/Powerware9390-Pt-Br/xupsOutputSource)<4 name: '{HOSTNAME} Checagem de Status da UPS!' priority: WARNING - uuid: f344483fa2064b88bf01a9660c460680 expression: last(/Powerware9390-Pt-Br/xupsOutputSource)=11 name: '{HOSTNAME} está em Manual Bypass' priority: WARNING - uuid: 6e6caba9df2446bbaff740d52989288b expression: last(/Powerware9390-Pt-Br/xupsOutputSource)=4 name: '{HOSTNAME} está no Automático Bypass' priority: WARNING - uuid: 7b332e278f444c75825bd82b2ef32158 expression: last(/Powerware9390-Pt-Br/xupsOutputSource)=5 name: '{HOSTNAME} na Bateria' priority: AVERAGE - uuid: 8d3eba91c37b4aab8aed141ba31fb89c name: 'Tensão de Saída A-N' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.534.1.4.4.1.2.1 key: xupsOutputVoltagea delay: '30' history: 14d trends: 30d units: V tags: - tag: Application value: Saída - uuid: d28897d7acd448ca9f8eb2a9b61010d7 name: 'Tensão de Saída B-N' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.534.1.4.4.1.2.2 key: xupsOutputVoltageb delay: '30' history: 14d trends: 30d units: V tags: - tag: Application value: Saída - uuid: e03a8c0adb0341d38fde996698459313 name: 'Tensão de Saída C-N' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.534.1.4.4.1.2.3 key: xupsOutputVoltagec delay: '30' history: 14d trends: 30d units: V tags: - tag: Application value: Saída - uuid: 2ef9641929dd4879b9c934d5bcda67af name: 'Potência de Saída Fase A' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.534.1.4.4.1.4.1 key: xupsOutputWattsa delay: '30' history: 14d trends: 30d units: W tags: - tag: Application value: Saída - uuid: 79b0bb6e1dd84e9faab58bd5d00f7359 name: 'Potência de Saída Fase B' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.534.1.4.4.1.4.2 key: xupsOutputWattsb delay: '30' history: 14d trends: 30d units: W tags: - tag: Application value: Saída - uuid: a8bf8912a7774766802c1fc3cd7c4397 name: 'Potência de Saída Fase C' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.534.1.4.4.1.4.3 key: xupsOutputWattsc delay: '30' history: 14d trends: 30d units: W tags: - tag: Application value: Saída - uuid: 15adfb51e6474139ac0e1d190796fcb9 name: 'Status do Teste da Bateria' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.534.1.8.2.0 key: xupsTestBatteryStatus delay: '30' history: 14d trends: 30d tags: - tag: Application value: 'Status da UPS' triggers: - uuid: 6050a6600bed494a8f104aa3e267e446 expression: last(/Powerware9390-Pt-Br/xupsTestBatteryStatus)=3 name: '{HOSTNAME} teste de Bateria Falhou' priority: HIGH graphs: - uuid: a7925fd977074dd09f16c0ea6cc50b05 name: 'Влажность в пом. ИБП' ymin_type_1: FIXED ymax_type_1: FIXED graph_items: - color: '009900' item: host: Powerware9390-Pt-Br key: xupsEnvRemoteHumidity - uuid: 70c7ed19541f453681b2cc924ed2128c name: 'Выходная мощность' show_work_period: 'NO' show_triggers: 'NO' graph_items: - color: '009900' item: host: Powerware9390-Pt-Br key: xupsOutputWattsa - sortorder: '1' color: 3333FF item: host: Powerware9390-Pt-Br key: xupsOutputWattsc - sortorder: '2' color: FF3333 item: host: Powerware9390-Pt-Br key: xupsOutputWattsb - uuid: 484b1d0f6de546749c67e5fa1c974c8d name: 'Напряжение на входе' show_triggers: 'NO' graph_items: - color: '009900' item: host: Powerware9390-Pt-Br key: xupsInputVoltage - sortorder: '1' color: EE0000 item: host: Powerware9390-Pt-Br key: xupsInputVoltagec - sortorder: '2' color: 0000EE item: host: Powerware9390-Pt-Br key: xupsInputVoltageb - uuid: 5a1d8ea98ce3486f86c1a30362f61a3d name: 'Температура в 108 (ИБП)' yaxismin: '10' yaxismax: '30' ymin_type_1: FIXED ymax_type_1: FIXED graph_items: - color: '009900' item: host: Powerware9390-Pt-Br key: xupsEnvRemoteTemp - uuid: 50e5b985c26d4b53a7e32208f5009f41 name: 'Ток на входе' graph_items: - color: '009900' item: host: Powerware9390-Pt-Br key: xupsInputCurrenta - sortorder: '1' color: FF3333 item: host: Powerware9390-Pt-Br key: xupsInputCurrentb - sortorder: '2' color: 3333FF item: host: Powerware9390-Pt-Br key: xupsInputCurrentc