zabbix_export: version: '5.4' date: '2021-11-25T12:35:09Z' groups: - uuid: 7df96b18c230490a9a0a9e2307226338 name: Templates - uuid: 57b7ae836ca64446ba2c296389c009b7 name: Templates/Modules - uuid: 0e60ac85bc3941e2a1d66a048ff164da name: UPS templates: - uuid: 49e7f17f552442f1b3198ea53711bdfc template: 'NetAgent UPS' name: 'NetAgent UPS' templates: - name: 'Template Module ICMP Ping' groups: - name: Templates - name: UPS items: - uuid: d81c49a8c96b43f7baab5f786f262008 name: 'UPS battery status' type: SNMP_AGENT snmp_oid: .1.3.6.1.4.1.935.1.1.1.2.1.1.0 key: netagent.battery.status delay: 30m valuemap: name: apcBatteryStatus tags: - tag: Application value: Operational triggers: - uuid: 7ee9dd0e03214d3eb32c68d57291aa43 expression: 'last(/NetAgent UPS/netagent.battery.status,#1:now-30m)=1 or last(/NetAgent UPS/netagent.battery.status,#1:now-30m)=4' recovery_mode: RECOVERY_EXPRESSION recovery_expression: 'last(/NetAgent UPS/netagent.battery.status,#1:now-30m)=2' name: 'UPS NetAgent - Batteries are unable to sustain the present load or are degraded' priority: HIGH manual_close: 'YES' - uuid: 5024d3397d5e495286965a967fd95eda expression: 'last(/NetAgent UPS/netagent.battery.status,#1:now-15m)=3' recovery_mode: RECOVERY_EXPRESSION recovery_expression: 'last(/NetAgent UPS/netagent.battery.status,#1:now-15m)=2' name: 'UPS NetAgent - Remaining battery run-time is poor' priority: AVERAGE description: 'Battery is low' manual_close: 'YES' - uuid: ea0b44a0825c475eb5ac33ba8e189e78 name: Uptime type: SNMP_AGENT snmp_oid: .1.3.6.1.2.1.1.3.0 key: sysUpTime units: uptime preprocessing: - type: MULTIPLIER parameters: - '0.01' tags: - tag: Application value: Status - uuid: e6e091a4e7a04eb98b8ba4489d7f1e2c name: 'UPS time on battery' type: SNMP_AGENT snmp_oid: .1.3.6.1.4.1.935.1.1.1.2.1.2.0 key: upsBaseBatteryTimeOnBattery delay: 60s history: 7d units: s description: | The elapsed time in seconds since the UPS has switched to battery power. Прошедшее время в секундах с момента переключения ИБП на батареи. preprocessing: - type: MULTIPLIER parameters: - '0.01' tags: - tag: Application value: Operational - uuid: cde872a2a14a42d08eedf160905a0e1d name: 'UPS Battery Last Replace Date' type: SNMP_AGENT snmp_oid: .1.3.6.1.4.1.935.1.1.1.2.1.3.0 key: upsBaseLBatteryLastReplaceDate delay: 1h trends: '0' value_type: TEXT description: | The date when the UPS system's batteries were last replaced in mm/dd/yy format. For UPS models, this value is originally set in the factory. When the UPS batteries are replaced, this value should be reset by the administrator Дата последней замены батарей системы ИБП в формате мм / дд / гг. Это значение изначально установлено на заводе. Когда батареи ИБП заменены, это значение должно быть сброшено администратором tags: - tag: Application value: information(s) - uuid: e36954cdc31a4e1ba5ded8dcf77bbd9e name: 'UPS status' type: SNMP_AGENT snmp_oid: .1.3.6.1.4.1.935.1.1.1.4.1.1.0 key: upsBaseOutputStatus delay: 30s description: | The current state of the UPS. If the UPS is unable to determine the state of the UPS this variable is set to unknown(1). valuemap: name: 'UPS NetAgent Status' tags: - tag: Application value: Operational - uuid: 36e27e9787da437c8431fa8607bf37ae name: 'UPS battery capacity (%)' type: SNMP_AGENT snmp_oid: .1.3.6.1.4.1.935.1.1.1.2.2.1.0 key: upsSmartBatteryCapacity delay: 60s history: 7d value_type: FLOAT units: '%' description: | The remaining battery capacity expressed in percent of full capacity. Оставшаяся емкость аккумулятора выражена в процентов от полной емкости. tags: - tag: Application value: Operational - uuid: 52b2a33780b14a2b988447d1ee0615ce name: 'UPS battery temperature' type: SNMP_AGENT snmp_oid: .1.3.6.1.4.1.935.1.1.1.2.2.3.0 key: upsSmartBatteryTemperature delay: 60s units: °C description: | The current internal UPS temperature expressed in tenths of a Celsius degree. Текущая внутренняя температура ИБП, выраженная в десятых долях градус Цельсия. preprocessing: - type: MULTIPLIER parameters: - '0.1' tags: - tag: Application value: Operational - uuid: 7de71e6aac584594aac89f0accf294b5 name: 'UPS Firmware Revision' type: SNMP_AGENT snmp_oid: .1.3.6.1.4.1.935.1.1.1.1.2.1.0 key: upsSmartIdentFirmwareRevision delay: 30s trends: '0' value_type: TEXT tags: - tag: Application value: information(s) - uuid: ead200a1c7bd42719cc0b018c2dcf014 name: 'UPS input voltage' type: SNMP_AGENT snmp_oid: .1.3.6.1.4.1.935.1.1.1.3.2.1.0 key: upsSmartInputLineVoltage delay: 30s value_type: FLOAT units: VAC preprocessing: - type: MULTIPLIER parameters: - '0.1' tags: - tag: Application value: Operational - uuid: f5e6edb246ad4abc81ad387c09906dce name: 'UPS output frequency' type: SNMP_AGENT snmp_oid: .1.3.6.1.4.1.935.1.1.1.4.2.2.0 key: upsSmartOutputFrequency delay: 30s units: Hz description: 'The current input frequency to the UPS system in 1/10 Hz.' preprocessing: - type: MULTIPLIER parameters: - '0.1' tags: - tag: Application value: Operational - uuid: ea82819b6635450cbc5f738bf823fdb2 name: 'UPS output load (%)' type: SNMP_AGENT snmp_oid: .1.3.6.1.4.1.935.1.1.1.4.2.3.0 key: upsSmartOutputLoad delay: 60s units: '%' description: | The current UPS load expressed in percent of rated capacity. tags: - tag: Application value: Operational - uuid: 101678b1f8184fe2bd134c1ffc35aa02 name: 'UPS output voltage' type: SNMP_AGENT snmp_oid: .1.3.6.1.4.1.935.1.1.1.4.2.1.0 key: upsSmartOutputVoltage delay: 30s units: VAC description: 'The output voltage of the UPS system in 1/10 VAC' preprocessing: - type: MULTIPLIER parameters: - '0.1' tags: - tag: Application value: Operational valuemaps: - uuid: b89c1deea0a643de8a3fa8ae47508eca name: apcBatteryStatus mappings: - value: '1' newvalue: unknown - value: '2' newvalue: batteryNormal - value: '3' newvalue: batteryLow - uuid: 425d2bfefa4f49e98215c413d20e7bb5 name: 'UPS NetAgent Status' mappings: - value: '1' newvalue: unknown - value: '2' newvalue: onLine - value: '3' newvalue: onBattery - value: '4' newvalue: onBoost - value: '5' newvalue: sleeping - value: '6' newvalue: onBypass - value: '7' newvalue: rebooting - value: '8' newvalue: standBy - value: '9' newvalue: onBuck - uuid: 37e5eb5606bc4abba66c8b20381a1e8a template: 'Template Module ICMP Ping' name: 'Template Module ICMP Ping' description: 'Template Module ICMP Ping version: 0.12' groups: - name: Templates/Modules items: - uuid: db5a94f6cea14deba957202b2f014469 name: 'ICMP ping' type: SIMPLE key: icmpping delay: '60' history: 1w valuemap: name: 'Service state' tags: - tag: Application value: Status triggers: - uuid: b030876299434f3ba43e11c584104a81 expression: 'max(/Template Module ICMP Ping/icmpping,#3)=0' name: 'Unavailable by ICMP ping' priority: HIGH description: | Last value: {ITEM.LASTVALUE1}. Last three attempts returned timeout. Please check device connectivity. - uuid: 04b21adaf422473a88df2c52786474ed name: 'ICMP loss' type: SIMPLE key: icmppingloss delay: '60' history: 1w value_type: FLOAT units: '%' tags: - tag: Application value: Status triggers: - uuid: 42c4b0310aaf4b9c8cb502542b7dea90 expression: 'min(/Template Module ICMP Ping/icmppingloss,5m)>{$ICMP_LOSS_WARN} and min(/Template Module ICMP Ping/icmppingloss,5m)<100' name: 'High ICMP ping loss' priority: WARNING dependencies: - name: 'Unavailable by ICMP ping' expression: 'max(/Template Module ICMP Ping/icmpping,#3)=0' - uuid: a79e33e5fd264725b934f603fa071555 name: 'ICMP response time' type: SIMPLE key: icmppingsec delay: '60' history: 1w value_type: FLOAT units: s tags: - tag: Application value: Status triggers: - uuid: 32b4d8f3eba34bd380803410111d4b7f expression: 'avg(/Template Module ICMP Ping/icmppingsec,5m)>{$ICMP_RESPONSE_TIME_WARN}' name: 'High ICMP ping response time' priority: WARNING dependencies: - name: 'High ICMP ping loss' expression: 'min(/Template Module ICMP Ping/icmppingloss,5m)>{$ICMP_LOSS_WARN} and min(/Template Module ICMP Ping/icmppingloss,5m)<100' - name: 'Unavailable by ICMP ping' expression: 'max(/Template Module ICMP Ping/icmpping,#3)=0' macros: - macro: '{$ICMP_LOSS_WARN}' value: '20' - macro: '{$ICMP_RESPONSE_TIME_WARN}' value: '0.15' valuemaps: - uuid: bdb5d65d925542eaa61c302dc40fbfe8 name: 'Service state' mappings: - value: '0' newvalue: Down - value: '1' newvalue: Up