5.02021-11-25T12:34:51ZTemplatesTemplates/ModulesSNMP Tripp Lite PDU 15SNMP Tripp Lite PDU 15Template Module ICMP PingTemplatesPDUPDU_OUTLETS_GROUPPDU_OUTLETS_NAMEPDU_OUTLETS_RAMP_ACTIONPDU_OUTLETS_RAMP_DELAYPDU_OUTLETS_SHAD_ACTIONPDU_OUTLETS_SHED_DELAYPDU_OUTLETS_STATESNMP Traps- SNMP traps (fallback)SNMP_TRAPsnmptrap.fallback0{$HISTORY}0LOGSNMP Trapshh:mm:sszyyyy/MM/dd
- Agent Software VersionSNMP_AGENT.1.3.6.1.4.1.850.1.2.1.1.2.0tlpAgentVersion86400{$HISTORY}0CHARThe UPS agent software version. This variable may or may not have the same value as upsIdentUPSSoftwareVersion in some implementations.PDU
- Low Transfer VoltageSNMP_AGENT.1.3.6.1.4.1.850.1.1.3.4.5.5.1.7.1.1tlpAtsConfigLowVoltageTransfer{$UPDATEINT}{$HISTORY}{$TRENDS}FLOATThe number of input voltages. Phase to phase or phase to neutral. This variable indicates the number of rows in the input table.PDUMULTIPLIER0.1
- Input - FrequencySNMP_AGENT.1.3.6.1.4.1.850.1.1.3.4.3.1.2.1.4.1.1.2tlpAtsInputPhaseFrequency{$UPDATEINT}{$HISTORY}{$TRENDS}FLOATPDUMULTIPLIER0.1
- Input - VoltageSNMP_AGENT.1.3.6.1.4.1.850.1.1.3.4.3.1.2.1.5.1.1.1tlpAtsInputPhaseVoltage{$UPDATEINT}{$HISTORY}{$TRENDS}FLOATThe number of input voltages. Phase to phase or phase to neutral. This variable indicates the number of rows in the input table.PDUMULTIPLIER0.1{last()}>{$MAX_INPUTVOLTAGE}PDU Power Voltage Too HighHIGH{last()}<{$MIN_INPUTVOLTAGE}PDU Power Voltage Too LowHIGH
- Maximum Input VoltageSNMP_AGENT.1.3.6.1.4.1.850.1.1.3.4.3.1.2.1.7.1.1.1tlpAtsInputPhaseVoltageMax{$UPDATEINT}{$HISTORY}{$TRENDS}FLOATThe number of input voltages. Phase to phase or phase to neutral. This variable indicates the number of rows in the input table.PDUMULTIPLIER0.1
- Input - Source AvailabilitySNMP_AGENT.1.3.6.1.4.1.850.1.1.3.4.3.1.1.1.12.1tlpAtsInputSourceAvailability30s0CHARReports power input sources for PDU.PDU{last()}<3PDU Lost Input RedundancyHIGHPDU has lost power redundancy. An input has failed.
- Output CurrentSNMP_AGENT.1.3.6.1.4.1.850.1.1.3.4.3.2.1.1.5.1.1tlpAtsOutputCurrent{$UPDATEINT}{$HISTORY}{$TRENDS}FLOATAmpsPDUMULTIPLIER0.01{last()}>{$MAX_OUTPUTCURRENT_CRITICAL}PDU Current Output Reaching LimitHIGH{last()}>{$MAX_OUTPUTCURRENT_WARNING}PDU Current Output Too HighWARNING
- Maximum Output CurrentSNMP_AGENT.1.3.6.1.4.1.850.1.1.3.4.3.2.1.1.7.1.1tlpAtsOutputCurrentMax{$UPDATEINT}{$HISTORY}{$TRENDS}FLOATAmpsPDUMULTIPLIER0.01
- Minimum Input VoltageSNMP_AGENT.1.3.6.1.4.1.850.1.1.3.4.3.2.1.1.6.1.1tlpAtsOutputCurrentMin{$UPDATEINT}{$HISTORY}{$TRENDS}FLOATThe number of input voltages. Phase to phase or phase to neutral. This variable indicates the number of rows in the input table.PDUMULTIPLIER0.1
- PDU Software VersionSNMP_AGENT.1.3.6.1.4.1.850.1.1.2.1.1.4.1tlpDeviceIdentFirmwareVersion86400{$HISTORY}0CHARThe UPS firmware/software version(s). This variable may or may not have the same value as upsIdentAgentSoftwareVersion in some implementations.PDU
- PDU Serial NumberSNMP_AGENT.1.3.6.1.4.1.850.1.1.2.1.1.5.1tlpDeviceIdentSerialNum86400{$HISTORY}0CHARSerial number for the UPS.PDU
- Device LocationSNMP_AGENT.1.3.6.1.4.1.850.1.1.1.2.1.8.1tlpDeviceLocation86400{$HISTORY}0CHARThe device location string.PDU
- Manufacturer IdentificationSNMP_AGENT.1.3.6.1.4.1.850.1.1.1.2.1.4.1tlpDeviceManufacturer86400{$HISTORY}0CHARThe name of the UPS manufacturer.PDU
- Model IdentificationSNMP_AGENT.1.3.6.1.4.1.850.1.1.1.2.1.5.1tlpDeviceModel86400{$HISTORY}0CHARThe UPS Model designation.PDU
- Device NameSNMP_AGENT.1.3.6.1.4.1.850.1.1.1.2.1.6.1tlpDeviceName86400{$HISTORY}0CHARA string identifying the UPS. This object should be set by the administrator.PDU
OutletsSNMP_AGENTdiscovery[{#SNMPVALUE},TRIPPLITE-PRODUCTS::tlpAtsOutletIndex]tlpAtsOutletIndex86400Outlet - Ramp data type of outlet $1SNMP_AGENT1.3.6.1.4.1.850.1.1.3.2.3.3.1.1.11.{#SNMPINDEX}tlAtsOutletRampDataType[{#SNMPVALUE}]1d{$HISTORY}{$TRENDS}The type of data associated with ramp action.PDU_OUTLETS_RAMP_DELAYUPS Outlet Ramp Data TypeOutlet - Ndx group of outlet $1SNMP_AGENT.1.3.6.1.4.1.850.1.1.3.4.3.3.1.1.14.1.{#SNMPINDEX}tlpAtsOutletGroup[{#SNMPVALUE}]1d{$HISTORY}{$TRENDS}tlPDUOutletGroupIndex of corresponding outlet group, or 0 if ungrouped.PDU_OUTLETS_GROUPOutlet - Name of outlet $1SNMP_AGENT.1.3.6.1.4.1.850.1.1.3.4.3.3.1.1.2.1.{#SNMPINDEX}tlpAtsOutletName[{#SNMPVALUE}]1d{$HISTORY}0CHARA string identifying the devices attached to the output(s) of the device.PDU_OUTLETS_NAMEOutlet - Ramp action of outlet $1SNMP_AGENT.1.3.6.1.4.1.850.1.1.3.4.3.3.1.1.10.1.{#SNMPINDEX}tlpAtsOutletRampAction[{#SNMPVALUE}]1d{$HISTORY}{$TRENDS}The ramp action to take on the Outlet.PDU_OUTLETS_RAMP_ACTIONUPS Outlet Ramp ActionOutlet - Shed action of outlet $1SNMP_AGENT.1.3.6.1.4.1.850.1.1.3.4.3.3.1.1.12.1.{#SNMPINDEX}tlpAtsOutletShedAction[{#SNMPVALUE}]1d{$HISTORY}{$TRENDS}The shed action to take on the Outlet.PDU_OUTLETS_SHAD_ACTIONUPS Outlet Shed ActionOutlet - Shed action data type of outlet $1SNMP_AGENT1.3.6.1.4.1.850.1.1.3.2.3.3.1.1.13.{#SNMPINDEX}tlpAtsOutletShedDataType[{#SNMPVALUE}]1d{$HISTORY}{$TRENDS}The type of data associated with shed action.PDU_OUTLETS_SHED_DELAYUPS Outlet Shed Data TypeOutlet - State of outlet $1SNMP_AGENT.1.3.6.1.4.1.850.1.1.3.4.3.3.1.1.4.1.{#SNMPINDEX}tlpAtsOutletState[{#SNMPVALUE}]2m{$HISTORY}{$TRENDS}The current state of the Outlet.PDU_OUTLETS_STATEUPS Outlet State{$MAX_INPUTVOLTAGE}125{$MAX_OUTPUTCURRENT_CRITICAL}12{$MAX_OUTPUTCURRENT_WARNING}10{$MIN_INPUTVOLTAGE}115{$SNMP_COMMUNITY}zabbixTemplate Module ICMP PingTemplate Module ICMP PingTemplate Module ICMP Ping version: 0.12Templates/ModulesStatus- ICMP pingSIMPLEicmpping601wStatusService state{max(#3)}=0Unavailable by ICMP pingHIGHLast value: {ITEM.LASTVALUE1}.
Last three attempts returned timeout. Please check device connectivity.
- ICMP lossSIMPLEicmppingloss601wFLOAT%Status{min(5m)}>{$ICMP_LOSS_WARN} and {min(5m)}<100High ICMP ping lossWARNINGUnavailable by ICMP ping{Template Module ICMP Ping:icmpping.max(#3)}=0
- ICMP response timeSIMPLEicmppingsec601wFLOATsStatus{avg(5m)}>{$ICMP_RESPONSE_TIME_WARN}High ICMP ping response timeWARNINGHigh ICMP ping loss{Template Module ICMP Ping:icmppingloss.min(5m)}>{$ICMP_LOSS_WARN} and {Template Module ICMP Ping:icmppingloss.min(5m)}<100Unavailable by ICMP ping{Template Module ICMP Ping:icmpping.max(#3)}=0
{$ICMP_LOSS_WARN}20{$ICMP_RESPONSE_TIME_WARN}0.15Input Frecuency80FIXEDFIXEDF6C800- SNMP Tripp Lite PDU 15tlpAtsInputPhaseFrequency
Input Voltage120FIXEDFIXEDF63100- SNMP Tripp Lite PDU 15tlpAtsInputPhaseVoltage
Output Current50FIXEDFIXEDFILLED_REGIONFF3333- SNMP Tripp Lite PDU 15tlpAtsOutputCurrent
Service state0Down1UpUPS Outlet Ramp Action0remainOff1turnOnAfterDelayUPS Outlet Ramp Data Type0delayInSecondsUPS Outlet Shed Action0remainOn1turnOffAfterDelayUPS Outlet Shed Data Type0delayInSecondsUPS Outlet State0unknown1off2on